X-Pro1 Service Manual Overview
X-Pro1 Service Manual Overview
X-Pro1
CAUTION
BECAUSE THIS PRODUCTIS RoHS LEAD-FREE COMPLIANT, USE THE DESIGNATED
AFTER-SELES PARTS AND THE DESIGNATED LEAD-FREE SOLDER WHEN
PERFORMING REPAIRS. (Refer to page 3)
WARNING
THE COMPONENTS IDENTIFIED WITH THE MARK " " ON THE SCHEMATIC
DIAGRAM AND IN THE PARTS LIST ARE CRITICAL FOR SAFETY.
PLEASE REPLACE ONLY WITH THE COMPONENTS SPECIFIED ON THE SCHEMATIC
DIAGRAM AND IN THE PARTS LIST.
IF YOU USE PARTS NOT SPECIFIED, IT MAY RESULT IN A FIRE AND AN ELECTRICAL
SHOCK.
SAFETY CHECK-OUT
After correcting the original problem, perform the following
safety check before return the product to the customer.
2
Confidential: FUJIFILM Service Center Use Only
component parts and materials used in this product are lead-free compliant under the European RoHS directive (*1). Use the
designated after-sales parts and the designated lead-free solder when performing repairs.
A lead content ratio of 0.1 wt% or less in the applicable locations (solder, terminals, electronic components, etc.)
<Lead-free soldering>
When lead-free solder is used, the solder tends to be less workable than when eutectic solder is used. When carrying out
repairs, use a designated lead-free solder, bearing in mind the differing work practices for eutectic solder and lead-free
solder.
■ Recommended equipment
lead-free
Wire diameter
SnAgCu
(1) Always cover the tip of the soldering iron with solder when it is not being used.
(2) If the tip is black from carbonization, wipe it gently with a paper towel soaked in alcohol until the solder will wet.
3
Confidential: FUJIFILM Service Center Use Only
MEMO
4
Confidential: FUJIFILM Service Center Use Only
CONTENTS
1. Disassembly ............................................................................................................1-1
2. Schematics ..............................................................................................................2-1
3. Adjustments ............................................................................................................3-1
4. Inspection ................................................................................................................4-1
8. Appendix...................................................................................................................8-1
5
Confidential: FUJIFILM Service Center Use Only
MEMO
6
Confidential: FUJIFILM Service Center Use Only
1. Disassembly
1-1. Removing the CASE
2
1
5
6 65
4 5 7
4
6 6
1-1
Confidential: FUJIFILM Service Center Use Only
9
8
10 11
12
[Assembly]
Assemble by performing the disassembly procedure in reverse.
Refer to the sheet sticking procedure.
Recycling prohibition of SHEET.
1-2
Confidential: FUJIFILM Service Center Use Only
1
2 2
1-3
Confidential: FUJIFILM Service Center Use Only
5
6
8
7
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-4
Confidential: FUJIFILM Service Center Use Only
2 3
1-5
Confidential: FUJIFILM Service Center Use Only
4
4 4 4
6 6
1-6
Confidential: FUJIFILM Service Center Use Only
7
7
7
7
8
8
8
8
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-7
Confidential: FUJIFILM Service Center Use Only
1-8
Confidential: FUJIFILM Service Center Use Only
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-9
Confidential: FUJIFILM Service Center Use Only
2
2
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-10
Confidential: FUJIFILM Service Center Use Only
1 1
1 1
1 1
4 3
8 7
6
1-11
Confidential: FUJIFILM Service Center Use Only
11
10
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-12
Confidential: FUJIFILM Service Center Use Only
4
1
3
2
5
5
1-13
Confidential: FUJIFILM Service Center Use Only
1-14
Confidential: FUJIFILM Service Center Use Only
10
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-15
Confidential: FUJIFILM Service Center Use Only
1
2
1-16
Confidential: FUJIFILM Service Center Use Only
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-17
Confidential: FUJIFILM Service Center Use Only
2
2
[Notes]
Be careful not to lose the NUT.
: Revised
1-18
Confidential: FUJIFILM Service Center Use Only
4
5
4
[Notes on Assembly]
SHEET CU is not reusable.
1-19
Confidential: FUJIFILM Service Center Use Only
1-20
Confidential: FUJIFILM Service Center Use Only
[Notes]
• Be careful not to lose the SHIM.
• The thickness and the number of SHIMs vary depending on their positions. Be sure to write down the positions
beforehand so that the same SHIMs will always be set to the same positions during assembly as the original
positions.
SHIM
10
11
11
11
11
[Notes]
When disassembling the CMOS UNIT, disassemble it [Sample image of a clean booth]
in a clean booth.
3
Compliant with ISO class 3 (0.3μm 100pcs/m ) or
better.
* Must clean up inside of the clean booth first before
you start clean up lenses.
1-21
Confidential: FUJIFILM Service Center Use Only
12
(13) Peel off the TAPE FPC, and remove the DR GLASS UNIT.
8
13
[Notes on Assembly]
• TAPE FPC is not reusable.
• Check the bosses to determine the position of the DR GLASS UNIT.
1-22
Confidential: FUJIFILM Service Center Use Only
15
14
14
14
1
16
15
1-23
Confidential: FUJIFILM Service Center Use Only
17
19
18 18
18 18
18 18
4 2
6 5
1 3
1-24
Confidential: FUJIFILM Service Center Use Only
20
[Notes on Assembly]
Be sure to apply the lubricant to the PSP MOUNT.
Lubricant: ZS00185-100 (HI-LUBE FG-600T)
Good Example
Bad Example
21
1-25
Confidential: FUJIFILM Service Center Use Only
[Notes on Assembly]
Be sure to apply the lubricant to the MOUNT LOCK.
Lubricant: ZS00135-200 (LUBRICANT CFD-409Z)
22
23
1-26
Confidential: FUJIFILM Service Center Use Only
(24) Remove the HOLDER MOUNT ASSY in the direction of the arrow.
24
[Assembly]
Assemble procedure is reverse of the disassembly procedure.
1-27
Confidential: FUJIFILM Service Center Use Only
1-10. Removing the CONST ASSY FRONT and CONST BATT, COVER BATTERY
(1) Remove the 3 screws (MSAM 1.4×2.5N).
1 1
(2) Remove the SHAFT in the direction of the arrow and then remove the COVER BATTERY.
[Assembly]
Assemble by performing the disassembly procedure in reverse.
1-28
Confidential: FUJIFILM Service Center Use Only
1-29
Confidential: FUJIFILM Service Center Use Only
1-30
Confidential: FUJIFILM Service Center Use Only
UL TAPE
Revised:[Link].2012
1-31
Confidential: FUJIFILM Service Center Use Only
UL TAPE
1-32
Confidential: FUJIFILM Service Center Use Only
(8) Affix the MASK_MOUNT on the HOLDER MOUNT ASSY as shown in the figure.
(9) Affix the TAPE FPCs on the MOUNT as shown in the figure.
: Revised
1-33
Confidential: FUJIFILM Service Center Use Only
(10) Affix the TAPE FPC on the BASE CMOS as shown in the figure.
(11) Affix the SHEET CU on the CMOUS UNINT as shown in the figure.
: Revised
1-34
Confidential: FUJIFILM Service Center Use Only
Revised:[Link].2012
1-35
Confidential: FUJIFILM Service Center Use Only
1-13. Procedure1
(1) I stick a seat and clean a part with ethanol.
<Clean an arrow part in particular chiefly.>
Type A
Revised:[Link].2012
1-36
Confidential: FUJIFILM Service Center Use Only
Type A
(5) I press it with a big part of push Tool in the arrow direction.
*1: Press it until I expose it to (2) red bars region in the state that I hinted to the red horizontal line
side of superior wall (1) and am accompanied.
*2: I move to the bottom for a thing of push Tool and press it until I put it, and (2) red bars region is accompanied.
*3: In the state that moved to the bottom for a thing of push Tool, and hinted to red horizontal line region of
left wall (3) in (2) red bars I press it until I put it and am accompanied.
*4: I divide the whole red frame moiety into three times and press it.
(Grip press tool Type B: ZJ01924-100)
Type B
1
Revised:[Link].2012
1-37
Confidential: FUJIFILM Service Center Use Only
(6) I commute in the arrow direction with a curve part of push Tool and press it.
*1: I press it by coming and going until I press it until I expose it to (2) red lines region in the
state that let you comply with curve part (1) of LENS side GRIP and am accompanied and expose
it to (3) red lines side and am accompanied.
*2: I divide the whole red frame moiety into three times and press it.
(Grip press tool Type C: ZJ01925-100)
2
Type C
2
1
3
1-14. Procedure2
(1) I stick SHEET GRIP F LEFT (①) on takeoff, CASE F.
Pasting standard: Top and bottom direction:CONST TOP insinuation.
Right and left direction: I make an insinuation at a lateral ups and downs shape.
Revised:[Link].2012
1-38
Confidential: FUJIFILM Service Center Use Only
Type A
Type A
Revised:[Link].2012
1-39
Confidential: FUJIFILM Service Center Use Only
(4) I press it with a big part of push Tool in the arrow direction.
*1: I press it until I expose it to (2) red horizontal lines region in the state that I hinted to the red bar
side of upper wall (1) and am accompanied.
*2: I move to the left side for a thing of push Tool and press it until I expose it to (2) red horizontal
line moiety and am accompanied.
*3: I divide the partial whole of the red frame into twice and press it.
(Grip press tool Type B: ZJ01924-100)
Type B
(5) I commute in the arrow direction with a curve part of push Tool and press it.
*1: I press it until I expose it to (2) red line region in the state that let the curve part of the LENS side
grip (1) go and am accompanied (3) I press it by coming and going until I put it and am assigned
to the red line side.
*2: Move to the left side for a thing of push Tool, and press it by coming and going until put it,
and (2) red line part is accompanied; in (3) red line side I press it by coming and going
until I put it and am accompanied.
*3: I repeat the work mentioned above to (4) red line part.
*4: I divide it into three times and press it.
4 1
Type C
2
3
4 1
Revised:[Link].2012
1-40
Confidential: FUJIFILM Service Center Use Only
1-15. Procedure3
(1) I take out SHEET GRIP R RIGHT ( ① ) and stick it on CASE R.
Pasting standard: Top and bottom direction : CONST TOP insinuation.
Right and left direction: I make an insinuation at a lateral ups and downs shape.
*1: I perform pasting up from the position becoming the standard of right and left direction
and the top and bottom direction.
*2: I stick the right and left course on the basis of around cross KEY part.
Type A
Revised:[Link].2012
1-41
Confidential: FUJIFILM Service Center Use Only
(3) I press it with a big part of push Tool in the arrow direction.
*1: I press it until I put it and am assigned to the red bar side of the right wall (1).
*2: It travels push Tool in the upper part of the card lid and presses it until I expose it to (2)
red horizontal line region and am accompanied.
*3: It travels push Tool in the bottom of the card lid and presses it until I expose it to (3)
red horizontal line moiety and am accompanied.
*4: I press it between (4) and (5) in the arrow direction.
*5: I divide the whole red frame moiety into three times and press it.
(Grip press tool Type B: ZJ01924-100)
Type B
2
1 4
(4) I commute in the arrow direction with a curve part of push Tool and press it.
*1: I press it until I expose it to (2) red line moiety in the state that let you go of the R LEFT side
grip curve part (1) and am accompanied and press it by coming and going until I expose it to (3)
red line side and am accompanied.
*2: I move to the right side for a thing of push Tool and press it by coming and going until I put it, and
(2) red line part is accompanied.
*3: I repeat the work mentioned above to (4) red line part.
*4: I divide it into three times and press it.
(Grip press tool Type C: ZJ01925-100)
1 Type C
4
Revised:[Link].2012
1-42
Confidential: FUJIFILM Service Center Use Only
1-16. Procedure4
(1) I stick SHEET GRIP R LEFT (①) on takeoff, CASE R.
Pasting standard: Top and bottom direction:CONST TOP insinuation.
Right and left direction: I make an insinuation at a lateral ups and downs shape.
*1: Perform pasting up from the position becoming the standard of right and left direction
and the top and bottom direction.
Type A
Revised:[Link].2012
1-43
Confidential: FUJIFILM Service Center Use Only
(3) I press the lower finder tip of SHEET GRIP R LEFT and the tip of each SW penumbra of
DRIVE/AF/AE in push Tool.
*1: SHEET not having the mixture such as alien substances.
*2: The thing that it runs, and there is not to a projection.
(Grip press tool Type A: ZJ01923-100) Type A
(4) I press it with a big mask of push Tool in the arrow direction.
*1: I press it until I expose it to (2) red horizontal line region in the state that I hinted to the
red bar side of the left wall (1) and am accompanied.
*2: On the right side of push, the Tool size move, and press it until put it, and (2)
red horizontal line part is accompanied.
*3: I divide the whole red frame moiety into twice and press it.
(Grip press tool Type B: ZJ01924-100)
1 Type B
2
Revised:[Link].2012
1-44
Confidential: FUJIFILM Service Center Use Only
(5) I commute in the arrow direction with a curve part of push Tool and press it.
*1: I press it until I expose it to (2) red line region in the state that let the R LEFT side grip
curve part (1) go and am accompanied and press it by coming and going until I expose
it to (3) red line side and am accompanied.
*2: I move to the right side for a thing of push Tool and press it by coming and going until
I press it by coming and going until I expose it to (2) red line moiety and am accompanied
and expose it to (3) red line side and am accompanied.
*3: I repeat the work mentioned above to (4) red line part.
*4: I divide it into three times, and press it.
(Grip press tool Type C: ZJ01925-100)
1 4 Type C
Type E
Revised:[Link].2012
1-45
Confidential: FUJIFILM Service Center Use Only
Type D
Revised:[Link].2012
1-46
Confidential: FUJIFILM Service Center Use Only
1-17. Procedure5
(1) I take out BASE GRIP F (①), and possess CASE F of the camera body and close
a screw (②) to CASE F.
*1: I tighten a screw while approaching to the thickness direction of the camera body and lose it.
Clamping order : ①→②→③→④
Screw total torque : 0.10±0.02N・m
2
4
1
3
(2) I take out TAPE GRIP F (③) and stick it on BASE GRIP F after detachment paper stripping.
Pasting standard: Direction of right and left: Chart below standard A part insinuation
Top and bottom direction: Chart below standard B part insinuation
*1: Perform pasting up from the position becoming the standard of right and left direction and
the top and bottom direction.
*2: Press the whole enough so that tape adheres.
Standard B
Standard A
Revised:[Link].2012
1-47
Confidential: FUJIFILM Service Center Use Only
Standard B
Standard A
(4) I take out LEVER FINDER (⑤), and possess CASE TOP and close a screw (⑥) to CASE TOP.
Screw total torque : 0.14±0.02N・m
(5) I take out DECO PLATE LEVER (⑦) and stick it on LEVER FINDER after detachment stripping.
Revised:[Link].2012
Revised:[Link].2012
1-48
Confidential: FUJIFILM Service Center Use Only
2
2 3
[Assembly]
Assemble by performing the disassembly procedure in reverse.
Revised:[Link].2012
1-49
Confidential: FUJIFILM Service Center Use Only
MEMO
1-50
Confidential: FUJIFILM Service Center Use Only
2. Schematics
2-1. Block Diagram
1.8V 3.3V
I2C_SCL1
New Current JTAG
I2C_SDA1
L5V L3.3V -1.5V 1.8V 4.5V 1.0V FLASH
3.3V Eye
COPRO_PW_EN 1.1V
1Gbit (NAND) MEDIA Vout SENSER
SD or SDXC
LENS MOUNT
SHUTTER UNIT
OLPF
CoPro_48M
Image Area CMOS IMX095 Co-Pro SD CARD
APS size
CoPro_PLLLOCK EVF 0.47” 3.3V
CDS ADC RST CARD BUS Slot
16 M pixels IBFC 1 44M
Parallel I/F
LVDS to
CoPro_RST
12bit Contro AUTO EVF BL 10V
CAM RECC EVF_RD[7:0], EVF_GD[7:0],
EVF_BD[7:0],EVF_CLK, CSIO_2
Adjustment Serial CCDIF EVF_HD,EVF_VD,EVF_RST_N EVF_CS_N CTL
parameter Tx MVBLK
EXI
CAM_D[0:7]_P/M EXDREQ EXDREQ MEDIA LCD Panel 3.3V
F UART LCD_D[7:0],LCD_CLK,
CAM_SCK_P/M
RECC EXDACK EXDACK MFT
LCD_HD,LCD_VD,LCD_RST_N
3.0”
YCPRO
RST
EXALE EXALE TFDC
EVR CSIO_2
0.92M
EXDWR EXDRW
Contro EXDCKO EXDCKO ENCD WDT
LCD_CS_N CTL
PIEZO
BUS120MHz
96MHz
SIO
CSIO CSIO_2
5V SENS_THM
I2C_SCL2
I2C_SDA2
CN Cable LCD_CS_N
LENS_PWON1/2
FPS DR USB2.0 8p
IO_AV_DET_
PeripheralBUS
LV8402GP
CSI0_3 CPU Core
+
CAM_CS_N PORT
CAM_THM_DA HMDI_INT
DR_IN1A/1
B
Peripheral
ICU
CHG_PI
XSW_PI
CHG_INA/B CSI0_3
CHG_MODEa/2 CoPro CS N
Face Detect
ADC
SM_OM,AM_ON IC I-cache 16k
D-
JPEG 16k cache
CSI0_1 TMDS
BUS Cont.
Output
FLASH-XE TTL_SHOE FLASH_XTrig SDRAMC I2C TTX0,TX1,
DMAC TTX2,TXC
Status Indicator Master HDMI
LED G I2C_SCI1
LED Level TypeC
I2C_SDA X’TAL HPD
LED
LED R SENSER 1
RCS I2S
CN
48.00M
CSI0_0 Hz 3.3V I/O Buffer ROM HDMI_DDSCL, 19pinI
MOT Drv
HVF / MOT_CS_N HDMI_DDSDA
BU24024GU
8kb x32
AFLED
1.8V 3.3V
KEY_PW_lever_DL
KEY_PW_lever
or SELF TIMER
KEY_S1_UIF_N
VBS_75_DA
EVF_BL DDR2 2Gb x32
ELPIDA
FPS_PI 1Gb 2
I2C_SCL
1 VDA DO Video
KOI CTL Driver
Li-ion_2Cell
7+2ch PMG_PW_CTL1 AU_DA SPEAKE
BATT AU_M_CLK
5V I2
NP-** AU B CLK,AU F CL
DA SP AM
S
1.1V
1260mAh Series DDRVDD
POWR AU_SDI AD STREO L-MIC
1.8V REG
HDMI AU_SDO MIC AM
1 5V
FUSE 3.3V CTL R-MIC
PMG_PW_CTL 0 / 1
2-1
Confidential: FUJIFILM Service Center Use Only
A B C D E
CN552 BL509_12G31
PI_T_E 1 2
PI_T_K 1 1 1 2
PI_T_V 1 0 1 1
FINDER PI_W_E
PI_W_K
9 10
8 9
0.5_NZIF 6 6 EVF_BL_C
LENS 7 8
1 UNIT
PI_P_E
PI_P_K
PI_P_V
DUMMY
6 7
5 6
4 5
CN12 0.5_NZIF
5
4
3
5 EVF_BL_C
4
3
2 EVF_BL_A
2
DUMMY 3 4 1 EVF_BL_A
2 3 1
DCM-
DCM+ 1 2
1 CN6 51281_0694 CN772
EVF FS-B+ 8
FS-A- 7 8
FS-A+ 6 7
11
CN771
VID12-B
SHUT FS-B- 5 6
NC 4 5
FSPR-C 3 4
0.5_NZIF 2 2
3 3
4 4
VID11-B
VID10-B
VID9-B
5 5
UNIT
FSPR-V 2 3
FSPR-E 1 2
CN551 51281_10894
CN8 6 6
7 7
8 8
VID8-B
VID7-B
VID6-B
EVF BL
VID5-B
9 9
EYELED_A 1 1 10 10
VID4-B
VID3-B TOP_PWB
DET EYE_DET 2 2
EYE_VCC 3 3
GND 4 4
0.5_NZIF
11 11
12 12
13 13
VID2-B
VID1-B
VID12-G
EVF
EYE_VIO 5 5 14 14
IC EYE SENSOR FPC I2C_1_SDA 6 6
I2C_1_SCL 7 7 CN8 15 15
16 16
VID11-G
VID10-G
VID9-G UNIT
GND 8 8 17 17 VID8-G
CN853 51281_0894
DR 3 3 3 3
18 18
19 19
20 20
VID7-G
VID6-G
VID5-G
0.47inch
LENS MOUNT DR 3 2 3 2
DR 3 1 3 1
BK_U
21 21
22 22
VID4-G
1.44M DETECTOR
DR 3 0 3 0
5V 2 9 2 9
5V 2 8 2 8
BK_L 23 23
24 24
25 25
VID3-G
VID2-G
VID1-G
5V 2 7 2 7
5V 2 6 2 6
5V 2 5 2 5
CN33 CN51 26 26
27 27
28 28
VID12-R
VID11-R
VID10-R
5V 2 4 2 4 29 29
VID9-R
VID8-R
S1/S2
5V 2 3 2 3 30 30
GND 2 2 2 2 31 31
VID7-R
VID6-R DIAL1/2
2 MOUNT FPC
GND 2 1 2 1
GND 2 0 2 0
GND 1 9 1 9
GND 1 8 1 8
32 32
33 33
34 34
35 35
VID5-R
VID4-R
VID3-R
FN
PWR
GND 1 7 1 7 VID2-R
GND 1 6 1 6
36 36
37 37
VID1-R
VSSX
EXT_TRG
DGND 1 5 1 5 38 38 DX
DGND 1 4 1 4 39 39
DGND 1 3 1 3
DGND 1 2 1 2
DGND 1 1 1 1
RCS 40 40
41 41
42 42
CLX
ENBX4
ENBX3
ENBX2
VIEWPWB
INTR_BUSY 1 0 1 0
VSYNC 9 9
MT_MOSI 8 8
System 43 43
44 44
45 45
ENBX1
NRG
VDD
STATUS
LED
MT_SCK 7 7 46 46
MT_MISO 6 6 DIRY
47 47 ENBY
LENS_DET_N 5 5 48 48 CLY
DUST
2 KEY_VIEW_UIF_N
3.3V 4 4 49 49
3.3V 3 3 DY
50 50 VSSY
3.3V 2 2 51 51
9690S_05Y901 NM
4 4 LED_G_ON_N
5 5 LED_R_ON_N
LCCOM
3.3V 1 1
REDUCTION Copro
3 3 +3_3VRUN
CN951 AYF333395DW1 CN2302
PIEZO
-
CN855
CN601 51281_1894 1 1 KEY_MODE2_DA_UIF 1 1
GND
CHG_PI_E 1 8 1 8 2 2 KEY_MODE2_DA_UIF
CN3601
Handsolder * 4 3 3 EV3 KEY_MODE1_DA_UIF 3 3
CHG_PI_C 1 7 1 7 KEY_FN_UIF_N 4 4
CHG_PI_V 1 6 1 6 4 4 KEY_MODE1_DA_UIF
5 5
CN23
1 1
5 5 KEY_FN_UIF_N KEY_POWER_UIF_N_pre
FOCAL
GND 1 5 1 5
6 6 KEY_POWER_UIF_N_pre MAIN KEY_S1_N_pre 6 6
2
X-SW 1 4 1 4 7 7
FPS COM(GND) 1 3 1 3
SM_DRV 1 2 1 2
7 7 KEY_S1_N_pre
8 8 KEY_S2_UIF_N
KEY_S2_UIF_N
STRB_TRG_EXT 8 8 14 14 EXT_CS
FPC SM_PI_V 1 0 1 0
SM_PI_C 9 9
0.5_NZIF
1 1 1 1 OUT6A STRB_EXT_CS_N 11 11
12 12 BK_U 11 11
10 10
GND
KEY_VIEW_UIF_N
SHOE
SHUTTER
SM_PI_E 8 8
(DUMMY) 7 7
1 2 1 2 STRB_EXT_CS_N
1 3 1 3 +3_3VRUN TOP +3_3VRUN
CSIO0_SDO 13 13
14 14
9 9
8 8
+3_3VRUN
LED_R_ON_N
CHG_MODE_DRVA 6 6
CHG_MODE_DRVB 5 5
CHG_DRVA 4 4 CN18
1 4 1 4 CSIO0_SDO
1 5 1 5 LED_G_ON_N
1 6 1 6 CSIO0_SCK
FPC
LED_R_ON_N
CSIO0_SCK
LED_G_ON_N
15 15
16 16
CN16 7 7
6 6
LED_G_ON_N
MIC_L-
FPC
1 7 1 7 LED_R_ON_N KEY_VIEW_UIF_N 17 17 5 5 MIC_L+
CHG_DRVA 3 3 GND 18 18 4 4 MIC_R-
1 8 1 8 KEY_VIEW_UIF_N
3 CHG_DRVB 2 2
CHG_DRVB 1 1
BK_U
1 9 1 9 GND
2 0 2 0 MIC_L-
2 1 2 1 MIC_L+
MIC_L-
MIC_L+
MIC_R-
19 19
20 20
21 21
3 3
2 2
MIC_R+
OUT6A
1 1 OUTC6NB2301
CN101 2 2 2 2 MIC_R- MIC_R+ 22 22 BL509_14G31
FGB216-0611 FGB216-0611
2 3 2 3 MIC_R+ 23 23
11
2 2
3 3
4 4
GND
GND
+5VRUN
CN1201
GND
GND
GND
1
12
2
3 3
CN23 AYF332395DW1 MT
503566_5100
BK_DW
CN41 AYF332395DW1
+5VRUN +5VRUN 4 4
5 5 5 5 CN741
6 6
+5VRUN
+5VRUN
+5VRUN
+5VRUN 6 6 11 TOP
MIC
7 7 GND +5VRUN 7 7 BL+
2 L
CAM_PWB 8 8
9 9
10 10
11 11
12 12
-6VCMOS
+1_8VRUN
+1_8VRUN
+1_8VCMOS_A
GND
-6VCMOS
+1_8VRUN
+1_8VRUN
8 8
9 9
10 10
11 11
2
3 3
4 4
5 5
BL-
NC
VCOM
+1_8VCMOS_D +1_8VCMOS_A 12 12 PVDD
13 13 +1_8VCMOS_D +1_8VCMOS_D 13 13 6 6
14 14 +3_3VRUN +1_8VCMOS_D 14 14
VDD3
15 15 GND +3_3VRUN 15 15
7 7 VDD3CFP0
16 16 16 16 8 8 VDD3CFN0
pin
GND GND
17 17 GND GND 17 17 9 9
18 18 18 18
GVDD
BK_U 19 19
20 20
DOP00
DOM00
GND
GND
DP00
DM00
19 19
20 20
10 10
11 11
NVDD
VDM2CFP0
MIC
pin
FPS009_2900_0
22 22 DOM01 DP01 22 22 13 13
CN61 23 23
24 24
25 25
GND
DOP02
DM01
GND
23 23
24 24
25 25
14 14
15 15
VREFH
COMDC
CN903
13 13 SCRU_GND
14 14 SCLU_GND
15 15 SCLD_GND
16 16 SCRD_GND
26 26 GND DM02 26 26 16 16
2 CD/DAT3
VBRT
-
27 27 DOP03 GND 27 27
P1.5:P330
28 28 28 28 17 17 AVDD
11 11 COMON
DOM03 DP03
DAT2
29 29 29 29
8 8 DAT0
9 9 DAT1
30 30 DCKP GND 30 30 19 19
12 12 WP
34 34 DOM04 DP04 34 34
VDD2CFN4 AFLED
35 35 GND
CMOS DM04 35 35
22 22 VDD2CFP0
2
36 36
37 37
DOP05
DOM05
GND
DP05
36 36
37 37
23 23
24 24
V5D0D126C1F6N_05185 LCD UNIT
38 38 38 38
VDD
GND DM05 25 25 3.0inch.
39 39
40 40
41 41
42 42
DOP06
DOM06
GND
DOP07
GND
DP06
DM06
GND
39 39
40 40
41 41
42 42
SDCARD_CN 26 26
27 27
28 28
VDD
VDDIO_M
VDDIO_G 0.92M
43 43 DOM07 DP07 43 43 VSS
44 44
45 45
46 46
GND
GND
GND
to DM07
GND
GND
44 44
45 45
46 46
29 29
30 30
31 31
TEST
BLC
4 APS-CMOS 47 47
48 48
49 49
50 50
51 51
CAM_THM_DA
CAM_DC1
CAM_DC2
PMG_PW_CTL0
GND
GND
CAM_THM_DA
CAM_DC1
CAM_DC2
PMG_PW_CTL0
47 47
48 48
49 49
50 50
51 51
32 32
33 33
34 34
DVDD
XVD
XHD
DCLK
52 52
53 53
54 54
55 55
CAM_CLK
GND
CAM_HD
CAM_VD
MAIN GND
CAM_CLK
GND
CAM_HD
52 52
53 53
54 54
55 55
BK_L 35 35
36 36
37 37
D0
D1
D2
38 38
56 56
57 57
58 58
CAM_SCK
CAM_SDO
CAM_VD
CAM_SCK
56 56
57 57
58 58 CN61 39 39
D3
D4
59 59
60 60
61 61
CAM_CS_N
CAM_RST_N
GND
CAM_SDO
CAM_CS_N
CAM_RST_N
59 59
60 60
61 61
BK_L 40 40
41 41
42 42
D5
D6
GND
503425_6191
FPC GND
503425_6191
CN51 43 43
44 44
45 45
D7
VSS
XCS
SI
46 46 XSCK
47 47 XRST
48 48 TEST
49 49 VDDIO_G
50 50 TEST
CN852 51 51 -
CN3501 VSS
11
2 2
KEY_MVAEAF_UIF_N KEY_MVAEAF_UIF_N
2
11
2 REAR_PWB
3 3
4 4 SIDE 3 3
4 4 NJIF 11
CN856
FFC
CN3001
5 5 GND
9690S_05Y901
FFC 9690S_05Y901
GND 5 5
CN5 N-JIF 2 2
3 3
+3_3VRUN
KEY_UDLR
KEY_OBFS
+3_3VRUN
KEY_UDLR
OK/BACK/F/S
5
4 5
3 4
SIDE PWB KEY - -
CN5
4 4
5 5
KEY_PLAY_UIF_N
GND
KEY_PLAY_UIF_N
GND
2 3
1 2
1
U/D/L/R
11
9690S_05Y901
CN901
SHIELD_2_GND
9690S_05Y901
N-JIF OK/BACK
PLAY
CN6002 COMMAND
HDMI 2 2
3 3
4 4
DATA2+
DATA2-
-
SHIELD_1_GND
CN5
CN854 5 5
FINDER KEY_EVF_OVF_UIF_N
GND
1
2
3
1
2
3
KEY KEY_CMD_R_UIF_N
KEY_CMD_DET_N
1
2
1
2
NJIF TypeC 6 6
7 7
DATA1+
DATA1-
SHIELD_0_GND
4 KEY_CMD_L_UIF_N 3 3 CN5 8 8 DATA0+
5 FPC DETECTOR
9690S_05Y901
4
5 5 NJIF
CN5
KEY_EVF_OVF_UIF_N
GND
9690S_05Y901
4
5
4
5
Multi
9 9
10 10
11 11
DATA0-
SHIELD_C_GND
CLOCK+
- 12 12 CLOCK-
MT
CN BACKUP
13 13
14 14
CEC_GND
CEC
COMMAND FPC BATT. 15 15
16 16
17 17
SCL
SDA
GND 12 12
GND 11 11
GND 10 10
NC
GND 1 1
18 18
GND 9 9
VBUS 8 8
D- 7 7
GND 6 6
D+ 5 5
AV_DET_N 4 4
AUD_L 3 3
VBS 2 2
SPK 19 19
+5V
HotPlugDetect
FGY119-008100
CN851
AF GND 1 1
20 20 GND
10L_0000_CN2
21 21 GND
KEY_MVAEAF_1 2 2 22 22 GND
KEY_MVAEAF_2 3 3 23 23
CN902
FPC KEY_MVAEAF_DA 4 4
NJIF
24 24
GND
GND
-
-
DETECTOR GND 5 5 25 25 GND
9690S_05Y901 CN5 TCX3278_310187
-
MAIN_PWB
2-2
Confidential: FUJIFILM Service Center Use Only
%7
)
2-3
Confidential: FUJIFILM Service Center Use Only
2-3-2. SHOEFPC
D
/('
1 2 3 4 5 6 7 8 9
2-4
Confidential: FUJIFILM Service Center Use Only
3. Adjustments
3-1. Important point before adjustment (the internal memory deployment model)
3-1-1. The handling of image files in internal memory
Image files contained in the internal memory should be handled as described below.
<Procedure for handling images>
When either of following work is necessary, as many as possible of the image files should be extracted from the
camera's internal memory and then written into the internal memory in the repaired or replacement camera before
the camera is returned to the customer.
1. When the replacement camera is provided.
2. When the MAIN PWB ASSY is replaced.
--->When "MAIN PWB ASSY" is replaced, it is necessary to execute "Flash memory reset".
(When the "Flash memory reset" was executed, involve formatting the internal memory.)
*Note
For PTP-connected cameras, carry out the procedure in "ii. Procedure for PTP-connected cameras and images
that cannot be downloaded to a PC".
3-1
Confidential: FUJIFILM Service Center Use Only
Adjust the item shown by O in the table below at the part replacement of Y-10241MAIN PWB, UNIT MOUNT, CONST ASSY
FRONT and FP SHUTTER (Other part replacements need not be adjusted).
Replacing parts
Y-10241 CONST ASSY
No.
MAIN PWB ASSY
UNIT MOUNT
FRONT FP SHUTTER
Adjustment item
0 MAIN PWB Initialize([Link]) *1 O
1 Mount Data Write O O O
2 Level Adjustment(Normal temperature) O O O
3 CMOS Defect Correction O O O
4 Camera Adjustment O O O O
5 Level Adjustment(High temperature) O O O
6 EVF Adjustment O O O
7 Battery Voltage Adjustment O O O
8 Firmware Download Do not use it until there is an instruction.
Do the end setting when you end the adjustment software when you set
9 End Setting
the camera to the Jig mode.
* The firmware is not installed in new Y-10241MAIN PWB ASSY. When Firmware Download is not executed first, it doesn't
*1
operate normally.
When the Y-10241MAIN PWB ASSY has been replaced, always reset the MAIN PWB Initialize before making any other
adjustments.
: Revised
3-2
Confidential: FUJIFILM Service Center Use Only
<Step 1>
Download .NET Framework Version 2.0 from Microsoft.
(See the address below and light picture.)
[Link]
856EACB-4362-4B0D-8EDD-AAB15C5E04F5&displaylang=e
n
<Step 2>
After downloading the software, complete the installation as
directed by the Install wizard.
<Step 1>
Download Windows Installer from Microsoft.
(See the address below and light picture.)
[Link]
FBC5470-B259-4733-A914-A956122E08E8&displaylang=en
<Step 2>
After downloading the software, complete the installation as
directed by the Install wizard.
3-3
Confidential: FUJIFILM Service Center Use Only
Revised:[Link].2012
3-4
Confidential: FUJIFILM Service Center Use Only
(1) Brightness
160 ± 5cd/m2 (with LB145 filter)
No chart, center of pattern box
Minolta brightness meter LS-110 or equivalent
* Calibration method
Place the filter (LB145) against the pattern box. With
the filter (LB145) in contact with the brightness meter,
adjust the pattern box brightness to 160 ± 5cd/m2.
* Since this camera uses the USB for communications with the personal computer, in order to start the PC adjustment
software, [the DSC jig driver] needs to be installed in the personal computer beforehand.
* The DSC jig driver is the same as that for the FinePix S7000, so if this jig driver software is already installed in the personal
computer, it is not necessary to install it. The procedure is given below.
<Step 1>
DSC jig driver ([Link]) is downloaded from Web
server ([Link]
<Step 2>
Defrost the downloaded compression software
<Step 3>
Double-click [Link] in the folder of defrosted
ZJ00684-100 and install Fuji FILM DSC Jig Driver as
follows.
<Step 4>
Install the software in [C:\ProgramFiles\Fjig] according to the
instructions on the PC's screen.
3-5
Confidential: FUJIFILM Service Center Use Only
<Step1>
The adjustment software is downloaded from WEB, and
software is installed in the PC.
We have uploaded the “PC Adjustment Software
(ZJ01971-***.zip) for X-Pro1_W” on our website:
([Link]
<Step2>
“ZJ01971-***” is a compression of “ZIP type” file.
The “X-Pro1_W” folder can be done by extracting it by
“Compression software”.
Copy the “X-Pro1_W” folder to the “C” drive on the
Adjustment PC.
<Step 3>
Double-click the "Setup_X-Pro1_W_***.exe" adjustment
software installer file contained in the expanded
ZJ01971-*** folder.
<Step 4>
When the window shown on the right appears, click [Next].
<Step 5>
When the window shown on the right appears, click [Install].
(Installation then begins.)
3-6
Confidential: FUJIFILM Service Center Use Only
<Step 6>
When installation ends and the window shown on the
right appears, click [Finish].
<Step 1>
Click : Start
↓
Programs
↓
FUJIFILM REPAIR SERVICE
↓
X-Pro1_W Adjustment Software
↓
Uninstall X-Pro1_W Adjustment Software
<Step 2>
When the window shown on the right appears, click [Yes].
(Uninstallation then begins.)
<Step 3>
When uninstallation ends and the window shown on the
right appears, click [OK].
3-7
Confidential: FUJIFILM Service Center Use Only
<Step1>
Do format of SD card in a “FAT32” form.
Note:All data is erased when do Format of SD card.
3-8
Confidential: FUJIFILM Service Center Use Only
<Step2>
The SD BOOT software is downloaded from WEB.
We have uploaded the “SD BOOT Software X-Pro1 SD BOOT Soft ZJ01970-***.zip
(ZJ01970-***.zip) for X-Pro1” on our website:
([Link]
<Step3>
“ZJ01970-***” is a compression of “ZIP type” file.
The “X-Pro1 SD BOOT Soft” folder can be done by
extracting it by “Compression software”.
Copy the “X-Pro1 SD BOOT Soft” folder to the “C” drive
on the Adjustment PC.
<Step4>
Copy the “[Link]” file and “[Link]” file, which are
stored in the extracted “X-Pro1 SD BOOT Soft” folder,
under SD card.
Copy the “LX10RCS***.bin” file, which are stored in the
extracted “X-Pro1_W\SCRIPT\LX10\Firmware” folder,
rename to “[Link]” under SD card.
My Computer
3.5inch FD(A:)
(C:)
X-Pro1 SD BOOT Soft
[Link] My Computer
[Link] 3.5inch FD(A:)
(C:)
<X-Pro1 SD BOOT Soft> Removable disk
[Link]
[Link]
My Computer
[Link]
3.5inch FD(A:)
(C:) <X-Pro1 SD card(BOOT only)>
X-Pro1_W
SCRIPT
LX10
・Flash Adjustment
Firmware
LX10RCS***.bin
<X-Pro1 W PC Soft>
3-9
Confidential: FUJIFILM Service Center Use Only
3-10
Confidential: FUJIFILM Service Center Use Only
<Step 1>
Start
↓
Programs
↓
FUJIFILM REPAIR SERVICE
↓
X-Pro1_W Adjustment Software
↓
X-Pro1_W(BOOT)
<Step 2>
If adjustment stops at the window shown on the right, press
the [Enter] key to proceed.
<Step 3>
[Repair site ID input] Repair site ID input
The first time the adjustment software is launched, a window
0: SAPPORO A: USA F: BRITAIN Z: OTHERS
appears where you select the repair site ID recorded in the 2: KURIHARA B: CANADA G: GERMANY
camera during End Setting. 3: TOKYO C: HAWAII H: FRANCE
I: SPAIN
In this window, select the appropriate repair site. 5: OSAKA D: TAIWAN J: ITALY
8: FUKUOKA T: CHINA K: NETHERLANDS
E.g.: USA -> Press "A" on the keyboard. Q: SINGAPORE L: BELGIUM
M: SWEDEN
* Once this has been set, this window no longer appears on N: SWITZERLAND
the PC. O: NORWAY
P: FINLAND
* To reset the repair site ID, exit the adjustment software and
then delete C:\X-Pro1_W\[Link].
3-11
Confidential: FUJIFILM Service Center Use Only
<Step 4>
[Adjustment Software Start-up Screen]
Check the details and then press the [Enter] key to proceed.
<Step 5>
[Notes on using the adjustment software] Cautions When Using the X-Pro1_W Adjustment Software
1. Check the adjustment sequence needed when parts are 1. Adjust as follows after replacing parts.
replaced. [F1]Battery [F4]CMOS Data [F5]Camera [F9]MOUNT
[F8]Firmware Download [F12]End Setting
2. When the MAIN PWB ASSY has been replaced, carry [E]EVF [L]Level(Normal temperature) [H]Level(High temperature)
out the "MAIN PWB Initialize [I]" procedure before [I]MAIN PWB Initialize
starting the adjustment. |--------------------------------------------------------------------------------------------------------|
3. If you have used the adjustment software, always carry | Replaced Parts Adjustment Procedure |
| MAIN PWB : [I]->[F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12] |
out End Setting. | UNIT MOUNT : [F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12] |
4. Refer to the Service Manual for precautions and other |--------------------------------------------------------------------------------------------------------|
detailed information on adjustment. 2. When the MAIN PWB ASSY has been replaced, always
MAIN PWB Initialize before making any other adjustments.
3. Always run End Setting after using this adjustment software.
Check the details and then press the [Enter] key to proceed. 4. Proceed with adjustment after reading the cautions here,
and the relevant cautions noted in the Service Manual.
Press the [Enter] key to proceed to the Jig Mode Setup screen.
<Step 6>
[BOOT Mode Setup Screen] X-PRO1 BOOT Mode Setup Screen
For other adjustments, use the "NP-W126 Battery jig " and
Set the BOOT mode by using [DC COUPLER CP-W126 (AC Adapter (9.0V))]
supply power from the regulated power supply so that [7.20V
(+0.02V/-0.00V)] is displayed on the digital voltmeter.
(1) Connect the camera to the PC using the "USB cable".
1) Connect the [USB cable].
(2) Supply power to the camera. 2) Supply power to the camera.
3) Switch camera power ON while pressing the shutter button and up key.
(3) Switch camera power ON while pressing the shutter 4) Ensure that the LED is lit.
button and up key(I).
(4) Check that the LED is lit green When steps 1 to 4 are complete, press the [Enter] key on the PC.
<Step 7>
[MAIN PWB Initialize Screen]
(1) Pressing the [X]:Restart key interrupts the adjustment X-Pro1_W Initialize Screen
software and returns you to the [Adjustment Software
Start-up Screen].
However, the camera will not be recognized as a PTP or
[I] : MAIN PWB Initialize
Mass Storage device. *Only use for when the MAIN PWB has been replaced.
(Press the [X] key while the camera is in communication
with the PC. If you press the [X] key while the camera is
disconnected, the [Adjustment Software Start-up Screen]
may be slow to reappear and an error may appear in the
adjustment software.)
[X] : Restart
Revised:[Link].2012
3-12
Confidential: FUJIFILM Service Center Use Only
3-8-2. Launching the Adjustment Software other then [I]:MAIN PWB Initialize
<Step 1>
Click : Start
↓
Programs
↓
FUJIFILM REPAIR SERVICE
↓
X-Pro1_W Adjustment Software
↓
X-Pro1_W
<Step 2>
If adjustment stops at the window shown on the right, press
the [Enter] key to proceed.
<Step 3>
[Repair site ID input] Repair site ID input
The first time the adjustment software is launched, a
0: SAPPORO A: USA F: BRITAIN Z: OTHERS
window appears where you select the repair site ID 2: KURIHARA B: CANADA G: GERMANY
recorded in the camera during End Setting. 3: TOKYO C: HAWAII H: FRANCE
5: OSAKA I: SPAIN
In this window, select the appropriate repair site. D: TAIWAN J: ITALY
8: FUKUOKA T: CHINA K: NETHERLANDS
E.g.: USA -> Press "A" on the keyboard. Q: SINGAPORE L: BELGIUM
M: SWEDEN
* Once this has been set, this window no longer appears on N: SWITZERLAND
the PC. O: NORWAY
P: FINLAND
* To reset the repair site ID, exit the adjustment software
and then delete C:\X-Pro1_W\[Link].
3-13
Confidential: FUJIFILM Service Center Use Only
<Step 4>
[Adjustment Software Start-up Screen]
Check the details and then press the [Enter] key to proceed.
<Step 5>
[Notes on using the adjustment software] Cautions When Using the X-Pro1_W Adjustment Software
1. Check the adjustment sequence needed when parts are 1. Adjust as follows after replacing parts.
replaced. [F1]Battery [F4]CMOS Data [F5]Camera [F9]MOUNT
[F8]Firmware Download [F12]End Setting
2. When the MAIN PWB ASSY has been replaced, carry [E]EVF [L]Level(Normal temperature) [H]Level(High temperature)
out the "MAIN PWB Initialize [I]" procedure before [I]MAIN PWB Initialize
starting the adjustment. |--------------------------------------------------------------------------------------------------------|
3. If you have used the adjustment software, always carry | Replaced Parts Adjustment Procedure |
| MAIN PWB : [I]->[F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12] |
out End Setting. | UNIT MOUNT : [F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12] |
4. Refer to the Service Manual for precautions and other |--------------------------------------------------------------------------------------------------------|
detailed information on adjustment. 2. When the MAIN PWB ASSY has been replaced, always
MAIN PWB Initialize before making any other adjustments.
3. Always run End Setting after using this adjustment software.
Check the details and then press the [Enter] key to proceed. 4. Proceed with adjustment after reading the cautions here,
and the relevant cautions noted in the Service Manual.
Press the [Enter] key to proceed to the Jig Mode Setup screen.
<Step 6>
[Jig Mode Setup Screen] X-PRO1 Jig Mode Setup Screen
(1) When carrying out Battery Voltage Adjustment, use the (1) Set the Jig mode by using [NP-W126 Battery jig (7.2V)]
"NP-W126 Battery jig" and a regulated power supply set at Battery Voltage Adjustment.
(2) Set the Jig mode by using [DC COUPLER CP-W126 (AC Adapter (9.0V))]
to 7.2 V. at adjustments other than Battery Voltage Adjustment.
(2) For other adjustments, use the "NP-W126 Battery jig"
and supply power from the AC adapter (9V). 1) Connect the [USB cable].
2) Supply power to the camera using the jig
as appropriate for the adjustment details.
1. Connect the camera to the PC using the “USB cable”. 3) Switch camera power ON while pressing the shutter button and up key.
4) Ensure that the Led is lit.
2. Use the appropriate jig according to the adjustment
options to supply power. When steps 1 to 4 are complete, press the [Enter] key on the PC.
3. Turn the camera on while holding down the shutter
button and up key(I).
4. Check that the LED is lit green.
Revised:[Link].2012
3-14
Confidential: FUJIFILM Service Center Use Only
<Step 7>
[Displaying the firmware version]
If a firmware upgrade is required, separate instructions will Firmware=1.98
be provided.
Check the details and then press the [Enter] key to proceed. Vendor Name = FUJIFILM
Manufacturer = FUJIFILM
ProductName = X-Pro1
Device Type = CAMERA
SerialNo = 593130323431000000000000000000
Frame Work = 1.00
[X] : Restart
3-15
Confidential: FUJIFILM Service Center Use Only
[Required items]
SD card(BOOT only) Copy ZJ01970-100 and Firmware to SD card
NP-W126 Battery jig ZJ01936-100
<Step 1>
[Firmware Download]
(1) Insert the SD card(BOOT only) to the card slot.
(2) Connect Power cable (or jig).
(3) Switch camera power ON while pressing the Fn button and Command lever .
(4) Ensure that the LED. [GREEN blinking] -> [RED lighting] -> [ORANGE lighting] -> [RED/GREEN blinking] -> [GREEN
lighting]
(5) Turn the camera off.
(6) Remove the Power cable (or jig) from the camera.
(7) Remove the SD card from the camera.
*Does not USB cable during Firmware Download.
Revised:[Link].2012
3-16
Confidential: FUJIFILM Service Center Use Only
<Step 2>
(1) Connect Power cable (or jig).
(2) Connect the camera to the PC using the “USB cable”.
(3) Switch camera power ON while pressing the shutter button and up key.
<Step 3>
[Checking MAIN PWB Initialize] MAIN PWB Initialize
Implementation details
Always carry out this step if the MAIN PWB ASSY has been
(1) Reset the flash ROM and format the internal memory. replaced.
[Implementation details]
Press the [Y] key to begin "MAIN PWB Initialize".
Press the [C] key to cancel the procedure. 1. Reset the flash Rom and
Format the internal memory.
<Step 4>
[Ending MAIN PWB Initialize] MAIN PWB Initialize
(1) Turn the camera off.
MAIN PWB Initialize is completed.
(2) Remove the Power cable (or jig) from the camera.
(3) Remove USB cable from the camera. (1) Turn off power switch.
(4) Press the [Enter] key. (2) Remove the Power cable (or jig) from the camera.
(3) Remove USB cable from the camera.
(4) Press the [Enter] key.
Press the [Enter] key to return to the Adjustment Software
Start-up Screen.
3-17
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
Mount data for X-Pro1 ZJ01979-100
NP-W126 Battery jig ZJ01936-100
<Step 1>
Read the serial number of UNIT MOUNT.
The numbers shown at right are as follows.
7000051(7 digits)
The name of the MOUNT data file containing this number is
“[Link]”.
Cautions:
1. The MOUNT data file extension is “txt”. Depending
upon Windows settings, this extension may not be
displayed. In this case, change the settings to ensure that
it is displayed.
2. In addition to numbers, letters are also used in the
MOUNT serial No. The data file name is instructed in the
same manner in this case.
3. Ensure that the MOUNT serial No. is read correctly. If the
file name is read incorrectly MOUNT data for another
camera will be loaded when this file is used.
<Sample image>
Revised:[Link].2012
3-18
Confidential: FUJIFILM Service Center Use Only
<Step 2>
Download the ZIP file of top four digits from Web server ([Link]
Open [ZJ01979-100] in the LENS data folder, and download “LX10Mount_7000.zip”.
<Step 3>
Decompress “LX10Mount_7000.zip”.
--> “[Link]” is made.
<Step 4>
Insert a writable floppy disk into the floppy disk drive on the computer.
<Step 5>
Search for “[Link]”, and copy it onto the floppy disk.
Caution: Do not create a folder on the floppy disk when copying the data.
● *When you do not use the floppy disk, you can do the following way.
<Step 4>
Confirm the following folder on C drive.
C:\X-Pro1_W\MOUNT_DATA
<Step 5>
Search for “[Link]”, and copy it onto the folder “C:\X-Pro1_W\MOUNT_DATA”.
<Step 6>
Select [F9]:Mount Data Write in the adjustment item select Mount Data Write
screen.
<Preparations>
Mount the camera on a tripod.
<Step 7>
[Preparing the Mount Data Write]
Mount the camera on a tripod.
When you have completed the preparations, press the [Enter] When preparation is complete,
press the [Enter] key on the PC.
key to proceed. Take care not to vibrate the camera during
subsequent adjustment. -->The lens is extended when the [Enter] key is pressed.
<Step 8>
[Lens number input]
(1) Enter the 7-digit Mount number of camera in the input
box.
● *When you do not use the floppy disk, you can skip (2).
(2) Insert the floppy disk containing the Mount data into the
floppy disk drive.
<Step 9>
[Ending Mount Data Write]
Revised: [Link].2012
3-19
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
Lighting Illuminate the chart
FxHS20EXR/X100 Level Chart ZJ01849-100
X-Pro1 Level jig ZJ01935-100
Rotation axis Stand ZJ01858-100
NP-W126 Battery jig ZJ01936-100
FUJINON LENS XF18mm F2 R ---
Laser telemeter Marketing product. Please purchase it in a general merchandising store.
Maker : Makita, Model : SK308PZ
When it's following specification equal to "SK308PZ", the Laser telemeter
container is practicable.
・Precision : ±1mm/10m
・Line Point laser : X direction/Y direction
Center X direction
Revised:[Link].2012
3-20
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [L]: Level Adjustment(Normal temperature).
<Step 2>
[Preparing for Level Adjustment(Normal temperature)] Level Adjustment(Normal temperature)
(1) Prepare the Level chart.
(2) Mount the camera on the Level jig so that it is facing the (1) Prepare a Level chart (1000mm x 700mm or more)..
level chart. (2) Set the camera in the [Level Jig]..
(3) Set the distance between the camera and
(3) Adjust the positions so that the distance from the level the Level chart to 500 +-5mm
chart to the camera's lens-face is 500 +-5 mm.
When the camera temperature is less than 30 degrees, adjust it.
<Step 3>
[Level Adjustment(Normal temperature) initialization] Level Adjustment(Normal temperature)
(1) Set the camera and Level chart to designated distance. (1) Adjust the position of the camera so that the center of
the Level chart is displayed in the camera LCD.
When you have completed the preparations, press the [Enter] When preparations (1) is complete,
press the [Enter] key.
key to proceed.
A = 500 +-5mm
<Step 4>
(1) Set the Level jig in 0 degree.
Set up the posture of the camera in the angle of 0 degree.
3-21
Confidential: FUJIFILM Service Center Use Only
<Step 5>
(1) Set the Level jig in 20 degree.
Set up the posture of the camera in the angle of 20 degree.
<Step 6>
(1) Set the Level jig in 70 degree.
Set up the posture of the camera in the angle of 70 degree.
<Step 7>
(1) Set the Level jig in 90 degree.
Set up the posture of the camera in the angle of 90 degree.
3-22
Confidential: FUJIFILM Service Center Use Only
<Step 8>
(1) Set the Level jig in 270 degree.
Set up the posture of the camera in the angle of 270 degree.
<Step 9>
[Ending Level Adjustment(Normal temperature)]
3-23
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
PTB450F Pattern box
LB145 filter ZJ00699-100
NP-W126 Battery jig ZJ01936-100
FUJINON LENS XF35mm F1.4 R ---
(1) Brightness
160 ± 5cd/m2 (with LB145 filter)
No chart, center of pattern box
Minolta brightness meter LS-110 or equivalent
* Calibration method
Place the filter (LB145) against the pattern box. With
the filter (LB145) in contact with the brightness meter,
adjust the pattern box brightness to 160 ± 5cd/m2.
<Step 1>
Select [F4]: CMOS Defect Correction in the adjustment item select screen.
<Step 2>
[Preparing the CMOS Defect Correction pattern box] CMOS Defect Correction
<Preparations>
(1) Stick the LB145 filter in the center of the pattern box.
(2) Use a color temperature meter to set the color (1) Prepare the LB145 filter.
temperature to 6100 ± 50K. (2) Adjust the color temperature of the pattern box (PTB450)
to 6100+-50K.
(3) Use a luminance meter to set the luminance to 160 ± 5 (3) Adjust the luminance of the pattern box (PTB450)
to 160+-5cd/m2.
cd/m2. (4) Fix the camera on a tripod and set it in front of the
* Because adjustments to one setting will skew the other pattern box.
Revised:[Link].2012
3-24
Confidential: FUJIFILM Service Center Use Only
<Step 3>
[Inspection for S/N main]
Inspection for S/N main
(1) Set the distance between the camera and pattern box.
(2) Place the LB140 filter in front of the lens.
Maximum Maximum When preparations are complete, press the [Enter] key.
6mm 6mm
Camera
Filter(LB145)
(1) Set up the camera and the LB145 filter at the specified
distances.
(2) Position the LB145 filter at the designated location in
front of the lens.
When you have completed the preparations, press the [Enter] key to proceed.
Take care not to vibrate the camera during subsequent adjustment.
<Step 4>
[Ending CMOS Defect Correction]
After completing the adjustments, press the [Enter] key to
proceed.
The adjustment item select screen reappears.
3-25
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
PTB450F Pattern box
LB145 filter ZJ00699-100
NP-W126 Battery jig ZJ01936-100
FUJINON LENS XF35mm F1.4 R ---
Maximum Maximum
6mm 6mm
Camera
Filter(LB145)
<Step 1>
In the adjustment item select screen, select [F5]: Camera Adjustment.
<Step 2>
[Preparing the camera adjustment pattern box] Camera Adjustment
(1) Stick the LB145 filter in the center of the pattern box. <Preparations>
(2) Use a color temperature meter to set the color
temperature to 6100 ± 50K. (1) Prepare the LB145 filter.
(2) Adjust the color temperature of the pattern box (PTB450)
(3) Use a luminance meter to set the luminance to 160 ± 5 to 6100+-50K.
cd/m2. (3) Adjust the luminance
to 160+-5cd/m2.
of the pattern box (PTB450)
* Because adjustments to one setting will skew the other (4) Fix the camera on a tripod and set it in front of the
pattern box.
setting, the color temperature and luminance should be
cross-checked a number of times. (Repeat steps 2 and 3
several times.) When preparations (1) - (4) are complete,
press the [Enter] key on the PC.
(4) Remove the LB145 filter and fix the camera onto the XY
-->Lens is extended when the [Enter] key is pressed.
stage or tripod so that it is facing the pattern box.
Revised:[Link].2012
3-26
Confidential: FUJIFILM Service Center Use Only
<Step 3>
[Shutter adjustment] Shutter adjustment main
(1) Set the camera to designated distance.
(1) Set the distance between the camera and pattern box.
(2) Remove the LB145 filter and the R60 filter from front of the lens.
When you have completed the preparations, press the [Enter] When preparations are complete, press the [Enter] key.
key to proceed.
A = 6mm or less
B = 6mm or less
<Step 4>
[Aperture sensitivity decrease rate adjustment] Aperture sensitivity decrease rate adjustment
(1) Position the LB145 filter at the designated location in
(1) Set the distance between the camera and pattern box.
front of the lens. (2) Place the LB145 filter in front of the lens.
A = 6mm or less
B = 6mm or less
<Step 5>
[WB adjustment (3200K)] WB_3200K_NORMAL
(1) Remove the LB145 filter from the front of the lens.
(1) Set the distance between the camera and pattern box.
(2) Remove the LB145 filter from front of the lens.
When you have completed the preparations, press the [Enter] When preparations are complete, press the [Enter] key.
key to proceed.
A = 6mm or less
B = 6mm or less
<Step 6>
[Ending Camera Adjustment]
3-27
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
Lighting Illuminate the chart
FxHS20EXR/X100 Level Chart ZJ01849-100
X-Pro1 Level jig ZJ01935-100
Rotation axis Stand ZJ01858-100
NP-W126 Battery jig ZJ01936-100
FUJINON LENS XF18mm F2 R ---
Laser telemeter Marketing product. Please purchase it in a general merchandising store.
Maker : Makita, Model : SK308PZ
When it's following specification equal to "SK308PZ", the Laser telemeter
container is practicable.
・Precision : ±1mm/10m
・Line Point laser : X direction/Y direction
Center X direction
Revised:[Link].2012
3-28
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [H]: Level Adjustment(High temperature).
<Step 2>
[Preparing for Level Adjustment(High temperature)] Level Adjustment(High temperature)
(1) Prepare the Level chart.
(2) Mount the camera on the Level jig so that it is facing the (1) Prepare a Level chart (1000mm x 700mm or more)..
level chart. (2) Set the camera in the [Level Jig]..
(3) Set the distance between the camera and
(3) Adjust the positions so that the distance from the level the Level chart to 500 +-5mm
chart to the camera's lens-face is 500 +-5 mm.
When the camera temperature is more than normal temperature adjustment.
temperature +8 degree, adjust it.
When you have completed the preparations, press the [Enter]
key to proceed.
When preparations (1) - (3) are complete,
press the [Enter] key on the PC.
<Step 3>
[Level Adjustment(High temperature) initialization] Level Adjustment(High temperature)
(1) Adjust the position of the camera so that the center of
(1) Set the camera and Level chart to designated distance. the Level chart is displayed in the camera LCD.
key to proceed.
A = 500 +-5mm
<Step 4>
(1) Set the Level jig in 0 degree.
Set up the posture of the camera in the angle of 0 degree.
3-29
Confidential: FUJIFILM Service Center Use Only
<Step 5>
(1) Set the Level jig in 20 degree.
Set up the posture of the camera in the angle of 20 degree.
<Step 6>
(1) Set the Level jig in 70 degree.
Set up the posture of the camera in the angle of 70 degree.
<Step 7>
(1) Set the Level jig in 90 degree.
Set up the posture of the camera in the angle of 90 degree.
<Step 8>
[Ending Level Adjustment(High temperature)]
3-30
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
LCD adjustment jig ZJ00585-100
(The cable must be connected to a PCI-2747A board installed in a PC.)
LCD JIG COVER ZJ00631-100 (attach to the sensor to block the light)
NP-W126 Battery jig ZJ01936-100
5±2mm
Camera
LCD adjustment jig
X-Pro1
PC2747
AC-5V
USB cable
Revised:[Link].2012
3-31
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [F3]:EVF Adjustment.
<Step 2>
[Preparing for EVF Adjustment] EVF Adjustment
(1) Turn the camera off.
(1) Turn off power switch.
(2) Unplug the power cord from the camera. (2) Remove the Power cable (or jig) from the camera.
(3) Plug the power cord back into the camera. (3) Reconnect Power cable (or jig).
(4) Switch camera power ON.
(4) Turn the camera on. (5) Press the [Enter] key after green LED lights on.
(5) Check that the LED is lit green and then press the [Enter]
key.
<Step 3>
[Preparing for EVF Adjustment] EVF Adjustment
(1) Supply power to the sensor from the AC adapter and
< Preparations >
align the sensor so that it is in the EVF screen and all (1) Attach the sensor of the EVF adjustment jig
external light is excluded. to the center of the EVF monitor.
A = 5 +-2mm
<Step 4>
[Ending EVF Adjustment]
3-32
Confidential: FUJIFILM Service Center Use Only
[Required items]
Camera fixing jig If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
Regulated power supply
Digital Voltmeter
NP-W126 Battery jig ZJ01936-100
3-33
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [F1]: Battery Voltage Adjustment.
<Step 2>
[Preparing for Battery Voltage Adjustment] Battery Voltage Adjustment
Launch the adjustment software and connect the PC to the
<Preparations>
camera as shown in the figure before establishing
communication between them. 1. Check that the NP-W126 Battery jig and the camera are connected.
* If not, return to the Jig Mode Setup screen,
and connect the NP-W126 Battery jig and the camera.
* If you are not using the battery jig, briefly pause the 2. Supply power (7.2V) to the camera from
adjustment software (Ctrl+A) and then proceed to the "Jig the [NP-W126 Battery jig].
<Step 3>
[BATT_END] BATT_END
Adjust the voltage from the regulated power supply so that
[6.20V (+0.02V/-0.00V)] is displayed on the digital voltmeter.
<Step 4>
[BATT_AC] BATT_AC
Adjust the voltage from the regulated power supply so that
[8.65V(±0.1V)] is displayed on the digital voltmeter.
Revised: [Link].2012
3-34
Confidential: FUJIFILM Service Center Use Only
<Step 5>
[Restoring the Battery Voltage Adjustment default Battery Voltage Adjustment
voltage]
Adjust the voltage from the regulated power supply so that
[7.20V(±0.1V)] is displayed on the digital voltmeter.
Apply
Applyan
aninput
inputvoltage
voltageofof3.70V(+-0.1V)
7.20V(+-0.1V)ininthe
thebattery
batteryjig.
jig.
When you have completed the preparations, press the [Enter] When
Whenpreparations
preparationsare
arecomplete,
complete,press
pressthe
the[Enter]
[Enter]key.
key.
key to proceed.
<Step 6>
[Ending Battery Voltage Adjustment]
Revised: [Link].2012
3-35
Confidential: FUJIFILM Service Center Use Only
[Required items]
None
Revised:[Link].2012
3-36
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [F8]: Firmware Firmware Download
Firmware Download
Download.
LED lights to orange while downloading the firmware.
<Step 2> Do not turn off the power while downloading the firmware.
c:\X-Pro1_W\SCRIPT\LX10\Firmware\[Link]
<Step 3>
[Ending Firmware Download] Firmware Download
Firmware Download is completed
(6) Turn the camera off.
(1) Turn off power switch.
(7) Unplug the power cord from the camera. (2) Remove the Power cable (or jig) from the camera.
(8) Plug the power cord back into the camera. (3) Reconnect Power cable (or jig).
(4) Switch camera power ON while pressing the shutter button and up key.
(9) Turn the camera on while holding down the shutter (5) Press the [Enter] key after green LED lights on.
button and up key(I).
(10) Check that the LED is lit green and then press the [Enter]
key.
<Step 4>
[Checking Adjustment Value Protection Reset] Adjust Area Backup Reset
Adjustment value Protection Reset is completed
To apply the firmware, reset the EEPROM while protecting
(1) Turn off power switch.
the adjustment values. (2) Remove the Power cable (or jig) from the camera.
(1) Turn the camera off. (3) Reconnect Power cable (or jig).
(4) Switch camera power ON while pressing the shutter button and up key.
(2) Unplug the power cord from the camera. (5) Press the [Enter] key after green LED lights on.
(3) Plug the power cord back into the camera.
(4) Turn the camera on while holding down the shutter
button and up key(I).
(5) Check that the LED is lit green and then press the [Enter]
key.
--> The adjustment software returns to Start-Up screen
Press the [Enter] key to return to the Adjustment Software after press the [Enter] key.
Start-up Screen.
3-37
Confidential: FUJIFILM Service Center Use Only
Item Details
Repair Date Date information is acquired from the PC and written.
Administrator ID 01(01)
Repair Station U.S.A. 61(a) SAPPORO 30(0)
CANADA 62(b) KURIHARA 32(2)
HAWAII 63(c) TOKYO 33(3)
TAIWAN 64(d) OSAKA 35(5)
BRITAIN 66(f) FUKUOKA 38(8)
GERMANY 67(g) OTHER 7A(z)
FRANCE 68(h)
SPAIN 69(i)
ITALY 6A(j)
NETHERLANDS 6B(k)
BELGIUM 6C(l)
SWEDEN 6D(m)
SWITZERLAND 6E(n)
NORWAY 6F(o)
FINLAND 70(p)
SINGAPORE 71(q)
CHINA 74(t)
Repair Serial No. A serial No. is assigned automatically and written
[Required items]
None
3-38
Confidential: FUJIFILM Service Center Use Only
<Step 1>
In the adjustment item select screen, select [F12]: End Setting. End Setting
Check the details and then press the [Enter] key to proceed.
<Step 3>
[Destination setting] Destination setting
Look at the 3rd digit from the left in the camera's serial number
The destination is selected from an undermentioned list,
and then press the corresponding key. according to third character from left side of the serial number.
<Step 4>
[Checking the USB_ID and destination]
Check the details and then press the [Enter] key to proceed.
592D36323831110216E7211Z110001
<Step 5>
[Ending Adjustment]
(1) Turn the camera off.
(2) Disconnect the power cord from the camera. X-PRO1 Adjustment completed.
(3) Disconnect the USB cable from the camera.
1) Turn off power switch.
When you have completed these steps, press the [Enter] key. 2) Remove the Power cable (or jig) from the camera.
After the "OK" screen display, the Adjustment Software 3) Remove USB cable from the camera.
Start-up Screen reappears. 4) Press the [Enter] key.
(When adjust the same camera again, switch camera power off
--> The adjustment software returns to Start-Up screen
once, and please switch camera power on with a jig mode After press the [Enter] key.
again.)
3-39
Confidential: FUJIFILM Service Center Use Only
MEMO
3-40
Confidential: FUJIFILM Service Center Use Only
4. Inspection
4-1. Required Measuring Equipment
Parts number Measuring equipment Remarks
Power supply Regulated power supply
Digital voltmeter For general use
Ammeter For general use (able to measure 1mA or less)
TV Monitor For general use (with terminal HDMI)
HDMI CABLE For general use (Type A-C)
External Flash For general use (able to Synchronization Communication)
FUJINON LENS Commercial accessories
XF35mmF1.4R
Light viewer Common with FinePix Z800EXR.
* This is commercially available.
Manufacturer: HAKUBA, model numbers: items equivalent to
KLV-5700
ZJ01936-100 NP-W126 Battery jig Common with the adjustment JIG
ZJ00525-100 Macro Chart Resolution confirmation
ZJ00885-100 LCD INSPECTION DATA For LCD inspection (Download from the web)
ZPU0512-100 SD CARD ULTRA2 1GB To check inspection SD recording
ZJ00982-100 Multi Cable(USB/AV) for F30 Common with adjustment JIG
ZJ01848-100 FxX100 Line Chart New JIG
ZJ01988-100 Appearance inspection For finder inspection
sample chart
ZJ02093-100 X-Pro1 W Dust Inspection CMOS Dust Inspection software
Soft Ver.1.00
ZS00172-100 Cleaning paper
: Revised
Revised: [Link].2012
4-1
Confidential: FUJIFILM Service Center Use Only
4-2
Confidential: FUJIFILM Service Center Use Only
8 Manual focus check P mode (1) Set the manual focus(MF) mode. (1) Select the MF of a MF/S-AF/C-AF
(2) Turn the focus ring. changeover switch.
(3) Set the AF-S mode. (2) Focus change.
(3) MF indication disappear.
9 External Flash P mode (1) Set the tester’s + probe on the flash
operation check hot shoe X contacts and the
tester's – probe on the flash hot shoe
GND contact.
(2) Press the shutter button to take a (2) Thing which does decrease change by
Picture. resistance momentarily, and returns to
origin immediately.
(3) Turn the External Flash on.
(4) Connect the camera to the External
Flash with the synchronization code.
(5) Press the shutter button to take a (5) An External Flash emits light.
Picture.
(6) Disconnect the synchronization
code from camera.
(7) Turn the External Flash off.
10 Movie/audio Movie mode (1) Set the MOVIE mode.
recording check (2) Press shutter button. (2) Check that movie/audio recording
begins. Check that “REC” appears
on the LCD monitor.
(3) After 5 seconds, press shutter (3) Check that movie/audio recording
button. ends and that the data is recorded
on the SD card.
4-3
Confidential: FUJIFILM Service Center Use Only
14 Erase mode check Erase (1) Select “Erase” -> (1) Check that an erase message such
“ALL FRAMES” from the menu as the following appears:
and then press the “OK” button. Overseas: “ERASE ALL OK?”
China: “ OK?”
(2) Select "OK" and press the “OK” (2) Check that the recorded images are
button. erased.
(3) Turn the camera off.
(4) Disconnect the SD card from the
camera.
15 Playback mode Playback (1) Insert a LCD INSPECTION SD card. ZJ00855-100
check (2) Turn the camera on. ZPU0512-100
(3) If a message prompting the user to (3) <DISP/BACK>
set the date appears, press the butt
on specified on the right.
(4) Start up in playback mode.
(5) Check the playback image. (5) Check that the last image shot
appears, regardless of whether it
is automatic or manual. Check that
the date is displayed in the YYYY.
[Link] format.
16 LCD dust/defect Playback (1) Play back a completely black image. (1) Check that there are no noticeable ZJ00885-100
check dust flecks or stains (bright spots,
smears, flashing points, etc.) on the
screen.
(2) Play back a completely white (75%)
image.
17 EVF dust/defect Playback (1) Change to EVF display. (1) Push the VIEW MODE button. ZJ00885-100
check (2) Play back a completely white (75%) (2) Check that there are no noticeable
image. dust flecks or stains (bright spots,
smears, flashing points, etc.) on the
screen.
(3) Play back a completely black image.
18 Eye sensor check Playback (1) Set the Eye Sensor mode. (1) Push the VIEW MODE button and turn
(2) Bring eyes close to EVF in a state on the Eye Sensor.
displayed by LCD. (2) Displayed by EVF.
(3) Keep away eyes from EVF. (3) Displayed by LCD.
(4) Turn the camera off.
19 Battery low check P mode (1) Set the power supply voltage. (1) 7.80 V ± 0.10 V ZJ01936-100
(2) Select the mode dial setting. (2) Mode: IRIS AUTO/SS AUTO.
(3) Turn the camera on.
(4) Set the power supply voltage. (4) 6.40 V ± 0.04V
Check that the battery-low warning
(pre-end) appears.
(5) Turn the camera off. (5) Check the camera turns off.
(6) Remove battery and am connected
again once after progress more than
ten seconds.
20 Current P mode (1) Set the power supply voltage. (1) 7.80 V ± 0.10 V ZJ01936-100
consumption check (2) Select the mode dial setting. (2) Mode: IRIS AUTO/SS AUTO.
AF Mode: AF-S.
(3) Turn the camera on.
(4) Check the Macro mode. (4) Backup check.
(5) Macro mode is set as off.
(6) After the LCD live image appears, (6) 500 mA or less
check the current consumption.
4-4
Confidential: FUJIFILM Service Center Use Only
21 Variable power P mode (1) Look into the OVF and check the (1) In an EVF display, EVF lever is plulled.
lens check OVF display.
(2) EVF lever is pulled a long time and
check the variable power lens comes
out.
(3) Again EVF lever is pulled a long time
and the variable power lens
is returned.
(4) Turn the camera off.
22 Checking standby Power off (1) Chek the power supply voltage. (1) 7.80 V ± 0.10 V ZJ01936-100
current (2) Check the standby current when the (2) 0.5 mA or less
power is turned OFF.
(3) Disconnect the SD card from the
camera.
23 Removal of a (1) 35mm Lens is removed. (1) Garbage dose not enter to the inside
lens of
a lens mount.
There is no crease,bend,dent in a
(2) Lens mount cover is attached. mount pin.
24 Shipping (1) Mode dial. (1) Aperture value AUTO/Shutter Speed
inspection AUTO/ Exposure 0EV
(Inventory repairs (2) AF changeover switch. (2) AF-S
only) (3) SETUP frame no. (3) New: The default SETUP frame No.
setting is “Continuous”, but to clear
the number of frames in the frame
number memory to zero, you should
always change the setting to “New”
before turning the camera off.
(4) Variable power lens. (4) OFF
(5) Battery and cards not inserted. (5) Normal
(6) Battery cover. (6) Closed
(7) DC coupler cable cover. (7) Closed
(8) Terminal cover. (8) Closed
(9) Lens mount cover. (9) Set
(10) Synchronization terminal cover. (10) Set
(11) Power off. (11) The power supply is stopped after
the camera's shutdown sequence
ends.
* Setting and clearing date
(1) Connect the USB/AV CABLE from
the PC to the camera (ensure that
the PC is switched ON).
(2) Switch power ON (POWER_ON)
while pressing the shutter button and
button.
(3) Switch power OFF (POWER_OFF).
(4) Check that the date has been
cleared.
* Please downloaded from Web server ([Link] or [Link]
4-5
Confidential: FUJIFILM Service Center Use Only
Resolution Chart
ZJ01848-100
From the surface of the
mount
Figure.1
<STEP 1>
[Resolution Check initialization]
(1) 35mm Lens is attached.
(2) Set the Battery and SD card to the camera.
(3) Turn the camera on.
(4) Carry out the reset of Camera from MENU
(5) Set a camera as follows
1. Shooting mode : A (Aperture Value)
[Link] : 200
[Link] : Fluorescent light -3
[Link] value : F4
[Link] simulation : Standard
[Link]-timer : 2sec
(6) Fix a camera to a tripod, and point a camera to the
resolution chart.
(7) Set resolution chart at the position of 1200mm (+-3mm)
from the lens tip of the camera.
(8) Match a chart angle of view with LCD like figure 2.
(9) Photograph it. Figure.2
* If a self-timer begins to work, please do not touch the
camera.
4-6
Confidential: FUJIFILM Service Center Use Only
<STEP 2>
[Resolution Check]
(1) Check the resolution at the center and periphery of the
photography image with the monitor of the PC. Periphery
Periphery Center
[SPEC] * Check an image at actual size
Center : What the line of the part to say 20 can
distinguish.
Periphery: What the line of the part to say 15 can Periphery
Periphery
distinguish.
A judgment example
*Periphery
NG OK
<STEP 3>
[Ending Resolution Check]
If an OK, carry out the following..
(1) Carry out the reset of Camera from MENU.
(2) Turn the camera off.
(3) Disconnect from the tripod.
(4) Take out battery and SD card.
(5) Close the cover of Battery and Treminal.
(6) 35mm Lens is removed.
4-7
Confidential: FUJIFILM Service Center Use Only
UNIT MOUNT
UNIT MOUNT
Revised:[Link].2012
4-8
Confidential: FUJIFILM Service Center Use Only
<Step 2>
Remove the interchangeable lens from the camera.
<Step 3>
Hold the camera so that light goes to the CMOS and check if there are dusts on the CMOS surface either visually or by using a
microscope.
If dusts can be seen, use a blower to remove it ([Note]).
If the dusts cannot be removed using the blower, wipe the CMOS with a lens cleaner (OLYMPUS HYPER CLEAN EE-3310 or
Equivalent goods) and ZS00172-100 CLEANING PAPER or Equivalent goods.
Do not use a blower with a brush.
Using a blower-brush to clean the CMOS could scratch the CMOS surface.
[Note]
When swiping the CMOS, note that any metallic dusts on the CMOS surface will cause scratches in the CMOS surface during cleaning.
<Step 2>
“ZJ02093-***” is a compressed file of “ZIP”.
The “ZJ02093-***” folder can be decompressed by “Compression
software”.
Copy the “ZJ02093-***” folder to the “C” drive in the PC.
<Step 3>
Double-click the inspection software installer file of “Setup_X-
Pro1_W_DustInspection_***.exe” in the “ZJ02093-***” folder.
<Step 4>
When the window in the right appears, click [Next].
: Revised
4-9
Confidential: FUJIFILM Service Center Use Only
<Step 5>
When the window in the right appears, click [Install].
(Then, installation begins.)
<Step 6>
When the installation completes and the window in the right
appears, click [Finish].
: Revised
4-10
Confidential: FUJIFILM Service Center Use Only
<Step 2>
When the window in the right appears, click [Yes].
(Then, uninstallation begins.)
<Step 3>
When the uninstallation completes and the window in the right
appears, click [OK].
* In some cases, uninstalling the software does not remove all the files.
To completely remove all the files, delete the C:\X-Pro1_W_DustInspection folder after completing the uninstallation.
: Revised
4-11
Confidential: FUJIFILM Service Center Use Only
<Step 2>
Click: Start
↓
Programs
↓
FUJIFILM REPAIR SERVICE
↓
X-Pro1 W Dust Inspection Soft
↓
X-Pro1_W(DustInspection)
<Step 3>
If this procedure stops at the window in the right, press the [Enter]
key to proceed.
<Step 4>
1. Connect the camera to the PC using the “USB cable”.
2. Supply power to the camera.
3. Turn the camera on while holding down the shutter button
and selector up key ().
4. Confirm if the LED is on in green.
: Revised
4-12
Confidential: FUJIFILM Service Center Use Only
<Step 5>
(1) Place the VIEWER at a distance of 24mm or less from the
lens-face of the camera.
(2) Adjust the position of the camera so that the camera LCD
shows the center of the VIEWER is displayed.
<Step 6>
[OK]
If the inspection is OK, the window in the right will appear.
: Revised
4-13
Confidential: FUJIFILM Service Center Use Only
[NG]
If the inspection is NG, the window in the right will appear showing
the location of dusts.
<Step 7>
(1) Turn the camera off.
(2) Disconnect the USB cable from the camera.
[Note]
In a normal environment, dusts could stick to the CMOS surface.
Therefore, customers could complain about dusts on the CMOS and ask you to remove them again just after you have removed the
dusts and they use their cameras.
In order to prepare such cases, we recommend you to take pictures before and after you clean the CMOS. Depending on cases, we
think you need to show those pictures to customers.
: Revised
4-14
Confidential: FUJIFILM Service Center Use Only
5-2. AS-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB23163-100 MANUAL BAG
A102 FBB23194-100 BARCODE LABEL
A103 FBB23334-100 PRG ACC CDSIZE 01
A104 FBB23781-100 WWN PRINT CD-SIZE2
A105 FBB24290-200 LABEL PRODUCT E
5-3. E1-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB23163-100 MANUAL BAG
A102 FBB23193-100 BARCODE LABEL
A103 FBB23334-100 PRG ACC CDSIZE 01
A104 FBB23781-100 WWN PRINT CD-SIZE2
A105 FBB24290-200 LABEL PRODUCT E
5-4. EE-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB23163-100 MANUAL BAG
A102 FBB23193-100 BARCODE LABEL
A103 FBB23334-100 PRG ACC CDSIZE 01
A104 FBB23781-100 WWN PRINT CD-SIZE2
A105 FBB24290-200 LABEL PRODUCT E
5-5. EG-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB23163-100 MANUAL BAG
A102 FBB23193-100 BARCODE LABEL
A103 FBB23334-100 PRG ACC CDSIZE 01
A104 FBB23781-100 WWN PRINT CD-SIZE2
A105 FBB24290-200 LABEL PRODUCT E
A106 FBB24527-100 [Link] Y-10241
A107 FBB24531-100 TRAY Y-10241
A108 FBB24634-100 ACC BOX Y-10241
A109 FBB24774-100 HDPE BAG 190×200
A110 FBF08577-100 UNIT BELT RING
A111 FBL01619-200 LX10 OM EN
A112 FBU04414-100 CAMERA BOX ASSY
A113 FFZ06708-401 AC POWERCORD
A114 FFZ08017-100 USB CABLE L60
A115 FFZ09206-300 BATTERYPACK NP-W126W
5-6. EU-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB23163-100 MANUAL BAG
A102 FBB23193-100 BARCODE LABEL
A103 FBB23334-100 PRG ACC CDSIZE 01
A104 FBB23781-100 WWN PRINT CD-SIZE2
A105 FBB24290-200 LABEL PRODUCT E
5-7. RU-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB21384-101 RU STICKER
A102 FBB23163-100 MANUAL BAG
A103 FBB23193-100 BARCODE LABEL
A104 FBB23334-100 PRG_ACC_CDSIZE_01
A105 FBB23781-100 WWN_PRINT CD-SIZE2
5-8. CH-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB19104-105 正規品証明シール
A102 FBB23163-100 MANUAL BAG
A103 FBB23193-100 BARCODE LABEL
A104 FBB23780-101 CH SERVICE NETWORK 1
A105 FBB24290-100 LABEL PRODUCT W
5-9. JP-Model
•Black model
Ref No. Parts No. Description Comment
A101 FBB21304-100 WARRANTY JP
A102 FBB23163-100 MANUAL BAG
A103 FBB23193-100 BARCODE LABEL
A104 FBB24290-100 LABEL PRODUCT W
A105 FBB24527-100 [Link] Y-10241
MEMO
5-10
Confidential: FUJIFILM Service Center Use Only
M216 M219
M206
M204
M205 M209
M226 M212
M210
M222
: Revised
Revised: [Link].2012
6-1
Confidential: FUJIFILM Service Center Use Only
・ B la c k m o d e l
Re f No. P a rts N o . D e s c rip tio n Com m e nt
M 301 F B B 2 0 5 9 2 -1 0 0 N -M S 2 M 1 .7 X 3 .0
M 302 F B B 2 0 9 2 1 -1 0 0 N -M S G M 1 .7 X 2 .5
M 303 F B B 2 0 9 2 1 -4 0 0 N -M S G M 1 .7 X 4 .0
M 304 F B B 2 1 2 1 7 -3 0 0 M S 2 M 1 .7 X 3 .5
M 305 F B B 2 2 5 5 0 -A 0 0 M S 2 M 1 .4 X 2 .0
M 306 F B B 2 4 0 7 1 -1 0 0 N -M S G M 1 .7 X 2 .5 D
M 307 F B B 2 4 1 1 0 -1 0 0 L E V E R F IN D E R
M 308 F B B 2 4 1 4 2 -1 0 0 B A S E G R IP F
M 309 F B B 2 4 1 4 4 -1 0 0 G R IP F
M312 M 310 F B B 2 4 2 4 9 -1 0 0 S H E E T G R IP F R IG H T
M 311 F B B 2 4 2 5 0 -1 0 0 S H E E T G R IP F L E F T
M 312 F B B 2 4 2 5 1 -1 0 0 S H E E T G R IP R R IG H T
M302 M 313 F B B 2 4 2 5 2 -1 0 0 S H E E T G R IP R L E F T
M 314 F B B 2 4 2 8 8 -1 0 0 DE CO P L A T E L E V E R
M316 M 315 F B B 2 4 2 8 9 -1 0 0 T A P E G R IP F
M303 M 316 F F Z 0 9 2 1 0 -1 0 0 U N IT R IN G F IN D E R
M301
M310
M313
M303
M301
M304
M307
M305
M314
M308
M306
M315
M311
M309
6-2
Confidential: FUJIFILM Service Center Use Only
M407
M403
M404
M406 M405
: Revised
: Revised
6-3
Confidential: FUJIFILM Service Center Use Only
MEMO
6-4
Confidential: FUJIFILM Service Center Use Only
7. Electrical parts
[Note]
* Due to standardization, replacement in the parts list may
The components indicated by mark are critical for safety. be different from the parts list specified in the circuit or the
When indicated parts by reference number, please include components used on the set.
*Do not reuse removed parts. Always use new parts.
the board name.
PWB
Ref No. Parts No. Description Comment
diagram
MAIN PWB ASSY
[FUSE]
F501 FFP00039-403 FUSE
[BATTERY]
BT151 FFZ07531-100 BACKUP BATTERY
SHOE FPC ASSY
[LED]
- FFQDL0155-01 LED
7-1
Confidential: FUJIFILM Service Center Use Only
MEMO
7-2
Confidential: FUJIFILM Service Center Use Only
8. Appendix
8-1. List of Related Technical Updates Issued
To ensure that after-sales service is performed accurately, keep a record here of the technical updates issued that cover this
device.
Technical Update No. Date Title Details/Other
2012-029 21. Jan, 2012 Service manual revision Revised pages: P1-23 to P1-36
2012-123 27. Jun, 2012 Service manual revision Revised pages: P3-19, P3-34 and P3-35
2012-143 10. Aug, 2012 Service manual revision Revised pages: P5-1 to P5-9
2013-108 01 Jul 2013 Revision of Service Manual Revised page: P1-18 to P1-27, P1-33 to P1-34
and P6-3
2013-212 17 Oct 2013 Revision of Service Manual Revised page: P3-2 and P6-3
8-1
Confidential: FUJIFILM Service Center Use Only
8-2