S.Y.B.
Tech Power Electronics Laboratory (January 2020)
Experiment 4: 1-PHASE HALF WAVE CONTROLLED CONVERTER WITH R & RL LOAD
Aim: To study half wave controlled rectifier with R & RL-load.
Apparatus used: 1. Thyristor Kit
2. Connecting Wires
3. Oscilloscope
4. Multimeter
Theory:
Single-Phase Half-Wave Controlled Rectifier using R - load
The single-phase half-wave controlled rectifier uses a single thyristor with a load .In a
positive half cycle of source voltage ,thyristor is forward biased and when gate current
Ig is applied to the gate terminal at firing angle α then thyristor starts to conduct. The
output voltage will appear from ωt = α to ωt = π. At ωt = π, thyristor goes turned OFF. In
a negative half cycle, ωt = π to ωt = 2π, thyristor is reverse biased and output voltage is
zero during this period. Therefore, by changing the value of firing angle (α) the output
voltage can be controlled.
Single-Phase Half-Wave Controlled Rectifier using RL - load
The single-phase half-wave controlled rectifier uses a single thyristor with a RL load . In a
positive half cycle of source voltage thyristor is forward biased and when gate current Ig
is applied to the gate terminal at firing angle α then thyristor starts to conduct. The
output voltage will appear from ωt = α to ωt = π. At ωt = π, thyristor goes turned OFF
but current does not decay to zero because of the energy stored in inductor. The
negative voltage will appear from ωt = π to ωt = β. The load current decays to zero
at ωt = β and value of depends upon the ratio R/L. During ωt = β to ωt = 2π, the output
voltage is zero during this period. The angle β is called extinction angle and γ = (β – α) is
called conduction angle.
Circuit diagram:
Observation table:
Procedure:
With R-load:
1. Connect the circuit with R-load as shown in the circuit diagram.
2. Switch on the main supply.
3. Vary the firing angle, observe the load voltage waveform on CRO and note down the firing angle and
output voltage.
With RL-load:
1. Connect the circuit with R-L load as per the circuit diagram.
2. Switch on the main supply.
3. Vary the firing angle, observe the load voltage waveform on CRO and note down the firing angle and
output voltage.
Conclusion: