User Manual For 16SEER Inverter L Series

This document is an owner's manual for Lennox brand air conditioner models LI012CI-160P432, LI012HI-160P432, LI012CO-160P432, LI012HO-160P432, LI018CI-160P432, LI018HI-160P432, LI018CO-160P432, LI018HO-160P432, LI024CI-160P432, LI024HI-160P432, LI024CO-160P432, and LI024HO-160P432. It contains precautions for safe operation and maintenance, part names, operating instructions, maintenance procedures, installation instructions, and other important information. Safety warnings are provided throughout to prevent

Uploaded by

Leonel Luciano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
301 views57 pages

User Manual For 16SEER Inverter L Series

This document is an owner's manual for Lennox brand air conditioner models LI012CI-160P432, LI012HI-160P432, LI012CO-160P432, LI012HO-160P432, LI018CI-160P432, LI018HI-160P432, LI018CO-160P432, LI018HO-160P432, LI024CI-160P432, LI024HI-160P432, LI024CO-160P432, and LI024HO-160P432. It contains precautions for safe operation and maintenance, part names, operating instructions, maintenance procedures, installation instructions, and other important information. Safety warnings are provided throughout to prevent

Uploaded by

Leonel Luciano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

6SOLW$LU&RQGLWLRQHU

2:1(5
6 0$18$/
LENNOX  $ , 5 & 2 1 ' , 7 , 2 1 ( 5 6

02'(/
LI012CI-160P432 LI012HI-160P432
LI012CO-160P432 LI012HO-160P432
LI018CI-160P432 LI018HI-160P432
LI018CO-160P432 LI018HO-160P432
LI024CI-160P432 LI024HI-160P432
LI024CO-160P432 LI024HO-160P432

7KDQN\RXIRUVHOHFWLQJLENNOXDLUFRQGLWLRQHUV3OHDVHUHDGWKLVPDQXDO
FDUHIXOO\EHIRUHRSHUDWLRQDQGNHHSLWIRUIXUWKHUUHIHUHQFH
Content
Operation Notices
Precautions............................................................................................................1
Parts Name............................................................................................................6
ScreenOperation Guide
Buttons on remote controller .................................................................................8
Introduction for icons on display screen ............................................................... 8
Introduction for buttons on remote controller .........................................................9
Function introduction for combination buttons .....................................................13
Operation guide ...................................................................................................14
Replacement of batteries in remote controller .....................................................14
Emergency operation .......................................................................................... 15
Maintenance
Clean and Maintenance....................................................................................... 15
Malfunction
Malfunction analysis ............................................................................................18
Installation Notice
Installation dimension diagram ............................................................................22
Tools for installation .............................................................................................23
Selection of installation location ..........................................................................23
Requirements for electric connection ..................................................................24
Installation
Installation of indoor unit......................................................................................25
Installation of outdoor unit ...................................................................................30
Vacuum pumping .................................................................................................33
Leakage detection ...............................................................................................33
Check after installation ........................................................................................34
Test and operation
Test operation ......................................................................................................34
Attachment
Configuration of connection pipe .........................................................................35
Pipe expanding method .......................................................................................37
Wired Controller................................................................................................... 38
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from un-
controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate-
rial resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for envi-
ronmental safe recycling.
Explanation of Symbols

Indicates a hazardous situation that, if not avoided, will


result in death or serious injury.

Indicates a hazardous situation that, if not avoided, could


result in death or serious injury.

Indicates a hazardous situation that, if not avoided, may


result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.

Indicates a hazard that would be assigned a signal word


WARNING or CAUTION.
Precautions

WARNING

Operation and Maintenance


This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock. .
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.

1
Precautions

WARNING

Maintenance must be performed by qualified


professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
Ɣ Power cord is overheating or damaged.
Ɣ There’s abnormal sound during operation.
Ɣ Circuit break trips off frequently.
Ɣ Air conditioner gives off burning smell.
Ɣ Indoor unit is leaking.

If the air conditioner operates under abnormal conditions,


it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.

2
Precautions

WARNING

Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table.Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.

3
Precautions

WARNING

Do not put through the power before finishing installation.


If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.

4
Precautions

WARNING

For the air conditioner with plug, the plug should be


reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.

Working temperature range

Indoor side DB/WB(ć ) Outdoor side DB/WB(ć )


Maximum cooling 26.7/19.4(80/66.9) 46.1/23.9(115/75)
Maximum heating 26.7/-(80/-) 23.9/18.3(75/64.9)
NOTICE:
Ɣ The operating temperature range (outdoor temperature) for cooling only unit is
-18ć(-0.4°F)~46.1℃(115°F);for heat pump unit is-20℃(-4°F)~46.1℃(115°F).

5
Parts Name
Indoor Unit
air inlet
panel

aux.button

horizontal louver
air outlet

F
C
HOUR
ONOFF

2 1 /2 ) )

 

02'( )$1

6:,1* ,)((/

 6/((3

7(03 7,0(521

&/2&. 7,0(52))

785%2 /,*+7 ;)$1

remote control
(Display content or position may be different from above
graphics, please refer to actual products)

Outdoor Unit
air inlet

Connection wire

air outlet

NOTICE:
Actual product may be different from above graphics, please refer to actual
products.

6
Parts Name
Display

For some model: For some model:


temp.
cooling power receiver indicator
indicator indicator window heating
indicator
display
cooling
indicator
power receiver
heating temp. drying indicator window
display
indicator indicator indicator
drying
indicator
For some model:
display

temp.
indicator Power LED color indicator:
receiver Green-status-ON.
window Red -status-OFF.

Mode LED color indicator:


W R G White-W-Cool Mode-
W

Red-R-Heat Mode- R
(only for heating model)

Green-G-Dry Mode- G

For some model:


display

temp.
indicator
Power LED color indicator:
receiver Green-status-ON.
window Red -status-OFF.
Mode LED color indicator:
W R O
White-W-Cool Mode-
W
Red-R-Heat Mode- R
(only for heating model)
Orange-O-Dry Mode- O

Display content or position may be different from above graphics, please refer to actual
products.

7
Buttons on remote controller
1 ON/OFF button
2 - button
F 3 + button
C
HOUR 4 MODE button
ONOFF

5 FAN button
1 2 1 /2 ) )
6 SWING button
2   3
7 I FEEL button
8 / button
4 02'( )$1 5 9 SLEEP button
6 6:,1* ,)((/ 7 10 TEMP button
8  6/((3 9 11 TIMER-ON button
10 7(03 7,0(521 11 12 CLOCK button
12 &/2&. 7,0(52)) 13 13 TIMER-OFF button
785%2 /,*+7 ;)$1
14 16 14 TURBO button
15 15 LIGHT button
16 X-FAN button

Introduction for icons on display screen


X-fan set fan speed
I feel send signal
8ć heating function turbo mode
Operation mode ventilation operation
health mode
Auto mode
Cool mode set temperature
Dry mode
Fan mode set time
Heat mode
TIMER ON/TIMER OFF
Clock
Sleep mode Child lock
light Up & down swing
Temp. display type
:Set temp. :Indoor ambient temp.
:Outdoor ambient temp.

8
Introduction for buttons on remote controller
Note:
Ɣ$IWHUSXWWLQJWKURXJKSRZHUDLUFRQGLWLRQHUZLOOJLYHRXWDVRXQGDQGRSHUDWLRQ
indicator " " is ON (red indicator). You can operate the air conditioner through
the remote controller.
Ɣ$W21VWDWXVDIWHUHDFKSUHVVLQJEXWWRQRQUHPRWHFRQWUROOHUWKHVLJQDOLFRQ
RQUHPRWHFRQWUROOHUZLOOÀDVKRQFH$LUFRQGLWLRQHUZLOOJLYHRXWDVRXQGZKLFK
indicates the signal has been sent to air conditioner.

1 ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.

2 - button
Press this button to decrease set temperature. Holding it down above 2 seconds
UDSLGO\GHFUHDVHVVHWWHPSHUDWXUH,Q$872PRGHVHWWHPSHUDWXUHLVQRW
adjustable.

3 + button
Press this button to increase set temperature. Holding it down above 2 seconds
UDSLGO\LQFUHDVHVVHWWHPSHUDWXUH,Q$872PRGHVHWWHPSHUDWXUHLVQRW
adjustable.

4 MODE button
(DFKWLPH\RXSUHVVWKLVEXWWRQDPRGHLVVHOHFWHGLQDVHTXHQFHWKDWJRHVIURP
$872&22/'5<)$1DQG+($7 DVWKHIROORZLQJ
AUTO COOL DRY FAN +($7

1RWH2QO\IRUPRGHOVZLWKKHDWLQJIXQFWLRQ

$IWHUHQHUJL]DWLRQ$872PRGHLVGHIDXOWHG,Q$872PRGHWKHVHWWHPSHUDWXUH
ZLOOQRWEHGLVSOD\HGRQWKH/&'DQGWKHXQLWZLOODXWRPDWLFDOO\VHOHFWWKHVXLWDEOH
operation mode in accordance with the room temperature to make indoor room
FRPIRUWDEOH $VIRUFRROLQJRQO\XQLWLWZRQ¶WKDYHDQ\DFWLRQZKHQLWUHFHLYHVWKH
signal of heating operation.)

9
Introduction for buttons on remote controller
5 FAN button
7KLVEXWWRQLVXVHGIRUVHWWLQJ)DQ6SHHGLQWKHVHTXHQFHWKDWJRHVIURP$872
WRWKHQEDFNWR$XWR
Auto

Low speed Medium speed High speed

6 SWING button
3UHVVWKLVEXWWRQWRVHWXS GRZQVZLQJDQJOHZKLFKFLUFXODUO\FKDQJHVDVEHORZ

OFF

7KLVUHPRWHFRQWUROOHULVXQLYHUVDO,IDQ\FRPPDQGRULVVHQWRXWWKHXQLW
will carry out the command as
indicates the guide louver swings as:

7 I FEEL button
Press this button to turn on I FEEL function. The unit automatically adjust tempera-
ture according to the sensed temperature. Press this button again to cancel I FEEL
function.

8 / button
Press this button to achieve the on and off of healthy and scavenging functions in
RSHUDWLRQVWDWXV3UHVVWKLVEXWWRQIRUWKH¿UVWWLPHWRVWDUWVFDYHQJLQJIXQFWLRQ
LCD displays " ". Press the button for the second time to start healthy and
VFDYHQJLQJIXQFWLRQVVLPXOWDQHRXVO\/&'GLVSOD\VDQG3UHVVWKLV
EXWWRQIRUWKHWKLUGWLPHWRTXLWKHDOWK\DQGVFDYHQJLQJIXQFWLRQVVLPXOWDQHRXVO\
3UHVVWKHEXWWRQIRUWKHIRXUWKWLPHWRVWDUWKHDOWK\IXQFWLRQ/&'GLVSOD\
Press this button again to repeat the operation above. (This function is applicable
to partial of models)

9 SLEEP button
Press this button to go into the SLEEP operation mode. Press it again to cancel
WKLVIXQFWLRQ7KLVIXQFWLRQLVDYDLODEOHLQ&22/+($7 2QO\IRUPRGHOVZLWK
heating function) mode to maintain the most comfortable temperature for you.

10
Introduction for buttons on remote controller
10 TEMP button
3UHVVWKLVEXWWRQFDQVHHLQGRRUVHWWHPSHUDWXUHLQGRRUDPELHQWWHPSHUDWXUHRU
RXWGRRUDPELHQWWHPSHUDWXUHRQLQGRRUXQLW¶VGLVSOD\7HPSHUDWXUHLVVHWFLUFXODUO\
by remote controller as below:
no display

Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHURUQRGLVSOD\WHPSHUDWXUHLQGLFDWRURQ
indoor unit displays set temperature.
Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHUWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLW
displays indoor ambient temperature.
Ɣ:KHQVHOHFWLQJE\UHPRWHFRQWUROOHUWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLW
displays outdoor ambient temperature.
Note:
Ɣ2XWGRRUDPELHQWWHPSHUDWXUHGLVSOD\PD\FDQ¶WEHVHOHFWHGIRUVRPHPRGHOV
:KHQLQGRRUXQLWUHFHLYHVVLJQDOLWGLVSOD\VLQGRRUVHWWHPSHUDWXUH
Ɣ2QO\IRUWKHPRGHOZKRVHLQGRRUXQLWKDVGXDOGLVSOD\

11 TIMER-ON button
3UHVVWKLVEXWWRQWRLQLWLDWHWKHDXWR21WLPHU7RFDQFHOWKHDXWRWLPHUSURJUDP
simply press this button again.
$IWHUSUHVVRIWKLVEXWWRQGLVDSSHDUVDQG21EOLQNVLVGLVSOD\HGIRU
21WLPHVHWWLQJ:LWKLQVHFRQGVSUHVVRUEXWWRQWRDGMXVWWKHWLPHYDOXH
Every press of either button changes the time setting by 1 minute. Holding down
either button rapidly changes the time setting by 1 minute and then 10 minutes.
:LWKLQ6HFRQGVDIWHUVHWWLQJSUHVV7,0(521EXWWRQWRFRQ¿UP

12 CLOCK button
3UHVV&/2&.EXWWRQEOLQNLQJ:LWKLQVHFRQGVSUHVVLQJRUEXWWRQDGMXVWV
the present time. Holding down either button above 2 seconds increases or
decreases the time by 1 minute every 0.5 second and then by 10 minutes every
VHFRQG'XULQJEOLQNLQJDIWHUVHWWLQJSUHVV&/2&.EXWWRQDJDLQWRFRQ¿UPWKH
VHWWLQJDQGWKHQZLOOEHFRQVWDQWO\GLVSOD\HG

13 TIMER-OFF button
3UHVVWKLVEXWWRQWRLQLWLDWHWKHDXWRRIIWLPHU7RFDQFHOWKHDXWRWLPHUSURJUDP
simply press the button again. TIMER OFF setting is the same as TIMER ON.

11
Introduction for buttons on remote controller
14 TURBO button
Press this button to activate / deactivate the Turbo function which enables the
XQLWWRUHDFKWKHSUHVHWWHPSHUDWXUHLQWKHVKRUWHVWWLPH,Q&22/PRGHWKHXQLW
ZLOOEORZVWURQJFRROLQJDLUDWVXSHUKLJKIDQVSHHG,Q+($7PRGHWKHXQLWZLOO
blow strong heating air at super high fan speed.

15 LIGHT button
Press LIGHT button to turn on the display's light and press this button again to turn
RIIWKHGLVSOD\
VOLJKW,IWKHOLJKWLVWXUQHGRQLVGLVSOD\HG,IWKHOLJKWLVWXUQHG
RIIGLVDSSHDUV

16 X-FAN button
3UHVVLQJ;)$1EXWWRQLQ&22/RU'5<PRGHWKHLFRQLVGLVSOD\HGDQGWKH
indoor fan will continue operation for 2 minutes in order to dry the indoor unit even
though you have turned off the unit.
$IWHUHQHUJL]DWLRQ;)$12))LVGHIDXOWHG;)$1LVQRWDYDLODEOHLQ$872)$1
or HEAT mode.

Function introduction for combination buttons


Combination of "+" and "-" buttons: About lock
Press "+" and "-" buttons simultaneously to lock or unlock the keypad. If the remote
FRQWUROOHULVORFNHGLVGLVSOD\HG,QWKLVFDVHSUHVVLQJDQ\EXWWRQEOLQNV
three times.

Combination of "MODE" and "-" buttons:


About switch between Fahrenheit and centigrade
$WXQLW2))SUHVV02'(DQGEXWWRQVVLPXOWDQHRXVO\WRVZLWFKEHWZHHQƒ&
DQGƒ)

12
Function introduction for combination buttons
Combination of "TEMP" and "CLOCK" buttons:
About Energy-saving Function
Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving
function. Nixie tube on the remote controller displays "SE". Repeat the operation to
TXLWWKHIXQFWLRQ

Combination of "TEMP" and "CLOCK" buttons:


About 8°C Heating Function
3UHVV7(03DQG&/2&.VLPXOWDQHRXVO\LQ+($7PRGHWRVWDUWƒ&+HDWLQJ
Function Nixie tube on the remote controller displays " " and a selected
WHPSHUDWXUHRIƒ& ƒ)LI)DKUHQKHLWLVDGRSWHG 5HSHDWWKHRSHUDWLRQWRTXLW
the function.

About Back-lighting Function


7KHXQLWOLJKWVIRUVZKHQHQHUJL]LQJIRUWKH¿UVWWLPHDQGVIRUODWHUSUHVV

ƾ About HEALTH function (COLD PLASMA)


7XUQRQWKHXQLWVWDUWXSWKHIDQ %UHH]LQJDQG;)$1DUHH[FOXGHG DQGSUHVV
HEATLTH button on remote controller to start health function (If there is not
+($/7+EXWWRQRQUHPRWHFRQWUROOHUWKHXQLWGHIDXOWVKHDOWKIXQFWLRQ21

13
Operation guide
1.$IWHUSXWWLQJWKURXJKWKHSRZHUSUHVV212))EXWWRQRQUHPRWHFRQWUROOHUWR
turn on the air conditioner.
2.3UHVV02'(EXWWRQWRVHOHFW\RXUUHTXLUHGPRGH$872&22/'5<)$1
HEAT.
3.3UHVVRUEXWWRQWRVHW\RXUUHTXLUHGWHPSHUDWXUH 7HPSHUDWXUHFDQ¶WEH
adjusted under auto mode).
4.3UHVV)$1EXWWRQWRVHW\RXUUHTXLUHGIDQVSHHGDXWRORZPHGLXPDQGKLJK
speed.
5. Press "SWING" button to select fan blowing angle.

Replacement of batteries in remote controller


1. Press the back side of remote controller marked battery
ZLWKDVVKRZQLQWKH¿JDQGWKHQSXVKRXW
reinstall
the cover of battery box along the arrow direction.
5HSODFHWZR $$$9 GU\EDWWHULHVDQG remove
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box. Cover of battery box

Note:
Ɣ'XULQJRSHUDWLRQSRLQWWKHUHPRWHFRQWUROVLJQDOVHQGHUDWWKHUHFHLYLQJ
window on indoor unit.
Ɣ7KHGLVWDQFHEHWZHHQVLJQDOVHQGHUDQGUHFHLYLQJZLQGRZVKRXOGEHQR
PRUHWKDQPDQGWKHUHVKRXOGEHQRREVWDFOHVEHWZHHQWKHP
Ɣ6LJQDOPD\EHLQWHUIHUHGHDVLO\LQWKHURRPZKHUHWKHUHLVÀXRUHVFHQWODPS
RUZLUHOHVVWHOHSKRQHUHPRWHFRQWUROOHUVKRXOGEHFORVHWRLQGRRUXQLWGXULQJ
operation.
Ɣ5HSODFHQHZEDWWHULHVRIWKHVDPHPRGHOZKHQUHSODFHPHQWLVUHTXLUHG
Ɣ:KHQ\RXGRQ¶WXVHUHPRWHFRQWUROOHUIRUDORQJWLPHSOHDVHWDNHRXWWKH
batteries.
Ɣ,IWKHGLVSOD\RQUHPRWHFRQWUROOHULVIX]]\RUWKHUH¶VQRGLVSOD\SOHDVH
replace batteries.

14
Emergency operation

If remote controller is lost or damaged, please use auxiliary button to turn


on or turn off the air conditioner. The operation in details are as below:

air conditioner. When the air conditioner is turned on, it will operate under
auto mode. panel
aux. button

WARNING:
Use insulated object to press the auto button

Clean and Maintenance

WARNING
Ŷ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.

Ŷ'RQRWZDVKWKHDLUFRQGLWLRQHUZLWKZDWHUWRDYRLGHOHFWULFVKRFN

Ŷ'RQRWXVHYRODWLOHOLTXLGWRFOHDQWKHDLUFRQGLWLRQHr.

Clean surface of indoor unit


When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.

NOTICE:
Ɣ'RQRWUHPRYHWKHSDQHOZKHQFOHDQLQJLW

15
Clean and Maintenance

Open panel
1 Pull out the panel to a certain
3 Ɣ8VHGXVWFDWFKHURUZDWHUWR

WKHZDWHU EHORZć ) to clean


LWDQGWKHQSXWLWLQDVKDG\
DQGFRROSODFHWRGU\.

4
panel cover tightl\.

WARNING

RSHUDWLRQHQYLURQPHQWFOHDQIUHTXHQF\FDQEHLQFUHDVHG

16
Clean and Maintenance

NOTICE: Checking before use-season

1. Check whether air inlets and air outlets are blocked.


2. Check whether air switch, plug and socket are in good condition.

4. Check whether mounting bracket for outdoor unit is damaged or corroded.


If yes, please contact dealer.
5. Check whether drainage pipe is damaged.

NOTICE: Checking after use-season

1. Disconnect power supply.

3. Check whether mounting bracket for outdoor unit is damaged or corroded.


If yes, please contact dealer.

Notice for recovery


1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.

17
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
FDQ¶WEHHOLPLQDWHGSOHDVHFRQWDFWORFDOGHDOHURUTXDOL¿HGSURIHVVLRQDOV

Phenomenon Check items Solution

Ɣ:KHWKHULW
VLQWHUIHUHGVHYHUHO\ Ɣ3XOORXWWKHSOXJ5HLQVHUW
(such as static electricity,stable the plug after about 3min, and
voltage)? then turn on the unit again.
Ɣ:KHWKHUUHPRWHFRQWUROOHULV
within the signal receiving Ɣ6LJQDOUHFHLYLQJUDQJHLVP
range?
Indoor unit Ɣ:KHWKHUWKHUHDUHREVWDFOHV" Ɣ5HPRYHREVWDFOHV
can’t receive Ɣ:KHWKHUUHPRWHFRQWUROOHULV ƔSelect proper angle and point
remote pointing at the receiving the remote controller at the re-
controller’s window? ceiving window on indoor unit.
signal or
Ɣ,VVHQVLWLYLW\RIUHPRWHFRQWUR Ɣ&KHFNWKHEDWWHULHV,IWKH
remote
OOHUORZIX]]\GLVSOD\DQGQR power of batteries is too low,
controller
display? please replace them.
has no
action. Ɣ&KHFNZKHWKHUUHPRWHFRQW
Ɣ1RGLVSOD\ZKHQRSHUDWLQJ
roller appears to be damaged.
remote controller?
If yes, replace it.
Ɣ7DNHWKHUHPRWHFRQWUROOHU
Ɣ)OXRUHVFHQWODPSLQURRP" close to indoor unit.
Ɣ7XUQRIIWKHÀXRUHVHQWODPS
and then try it again.

Ɣ$LULQOHWRUDLURXWOHWRILQGRRU Ɣ(OLPLQDWHREVWDFOHV
unit is blocked?
Ɣ8QGHUKHDWLQJPRGHLQGRRU Ɣ$IWHUUHDFKLQJWRVHWWHPSHU
No air temperature is reached to set ature, indoor unit will stop bl-
emitted temperature? owing out air.
from
indoor Ɣ+HDWLQJPRGHLVWXUQHGRQMXVW Ɣ,QRUGHUWRSUHYHQWEORZLQJ
unit now? out cold air, indoor unit will be
started after delaying for sev-
eral minutes, which is a nor-
mal phenomenon.

18
Malfunction analysis
Phenomenon Check items Solution

Ɣ3RZHUIDLOXUH" Ɣ:DLWXQWLOSRZHUUHFRYHU\
Ɣ,VSOXJORRVH" Ɣ5HLQVHUWWKHSOXJ
Ɣ$LUVZLWFKWULSVRIIRUIXVHLV Ɣ$VNSURIHVVLRQDOWRUHSODFH
burnt out? air switch or fuse.
Air condit- Ɣ:LULQJKDVPDOIXQFWLRQ" Ɣ$VNSURIHVVLRQDOWRUHSODFHLW
ioner can’t
operate Ɣ8QLWKDVUHVWDUWHGLPPHGLDWHO\
Ɣ:DLWIRUPLQDQGWKHQWXUQ
after stopping operation?
on the unit again.

Ɣ:KHWKHUWKHIXQFWLRQVHWWLQJ
for remote controller is Ɣ5HVHWWKHIXQFWLRQ
correct?

Ɣ%HFDXVHLQGRRUDLULVFRROHG
Mist is em-
rapidly. After a while, indoor
itted from Ɣ,QGRRUWHPSHUDWXUHDQGKXP
temperature and humidity will
indoor unit’s idity is high?
be decrease and mist will
air outlet
disappear.

Ɣ7HPSHUDWXUHFDQ¶WEHDGMX
sted under auto mode.
Ɣ8QLWLVRSHUDWLQJXQGHUDXWR
Please switch the operation
Set temper- mode?
mode if you need to adjust
ature can’t temperature.
be adjusted
Ɣ<RXUUHTXLUHGWHPSHUDWXUH
Ɣ6HWWHPSHUDWXUHUDQJH
exceeds the set temperature
16ć ~30ć .
range?

Ɣ:DLWXQWLOWKHYROWDJH
Ɣ9ROWDJHLVWRRORZ"
resumes normal.
Cooling Ɣ)LOWHULVGLUW\" Ɣ&OHDQWKH¿OWHU
(heating)
effect is Ɣ6HWWHPSHUDWXUHLVLQSURSHU Ɣ$GMXVWWHPSHUDWXUHWRSURSHU
not good. range? range.

Ɣ'RRUDQGZLQGRZDUHRSHQ" Ɣ&ORVHGRRUDQGZLQGRZ

19
Malfunction analysis
Phenomenon Check items Solution

Ɣ:KHWKHUWKHUH¶VRGRXUVRXUFH Ɣ(OLPLQDWHWKHRGRXUVRXUFH
Odours are
such as furniture and cigarette,
emitted Ɣ&OHDQWKH¿OWHU
etc.

Air conditio- Ɣ:KHWKHUWKHUH¶VLQWHUIHUHQFH Ɣ'LVFRQQHFWSRZHUSXWEDFN


ner operates such as thunder, wireless power, and then turn on the
abnormally devices, etc. unit again.

Ɣ'XULQJGHIURVWLQJXQGHUKH
Outdoor
ating mode, it may generate
unit has Ɣ+HDWLQJPRGHLVWXUQHGRQ"
vapor, which is a normal
vapor
phenomenon.

Ɣ7KHQRLVHLVWKHVRXQGRI
“Water
Ɣ$LUFRQGLWLRQHULVWXUQHGRQRU UHIULJHUDQWÀRZLQJLQVLGH
ÀRZLQJ´
turned off just now? the unit, which is a normal
noise
phenomenon.

Ɣ7KLVLVWKHVRXQGRIIULFWLRQ
Ɣ$LUFRQGLWLRQHULVWXUQHGRQRU caused by expansion and/or
Cracking
turned off just now? contraction of panel or other
noise
parts due to the change of
temperature.

20
Malfunction analysis
Error Code
Ɣ:KHQDLUFRQGLWLRQHUVWDWXVLVDEQRUPDlWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLWZLOO

DWLRQRIHUURUFRGH

(UURUFRGH TURXEOHVKRRWLQJ
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRWSOHDVH
E5

,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
E8

,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
U8

,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW,SOHDVH
H6

C5
F1
F2

1RWH,IWKHUH
UHRWKHUHUURUFRGHVSOHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH

WARNING
Ŷ:KHQEHORZSKHQRPHQRQRFFXUVSlHDVHWXUQRIIDLUFRQGLWLRQHUDQGGLVFRQ

IRUVHUYLFH
Ɣ3RZHUFRUGLVRYHUKHDWLQJRUGDPDJHG
Ɣ7KHUH’VDEQRUPDOVRXQGGXULQJRSHUDWLRQ
Ɣ$LUVZLWFKWULSVRIIIUHTXHQWOy
Ɣ$LUFRQGLWLRQHUJLYHVRIIEXUQLQJVPHOO
Ɣ,QGRRUXQLWLVOHDNLQJ

Ŷ,IWKHDLUFRQGLWLRQHURSHUDWHVXQGHUDEQRUPDOFRQGLWLRQVLWPD\FDXVH

1
Installation dimension diagram

Space to the ceiling

At least 15cm

Space to the wall


At least 15cm
At least 15cm
Space to the wall 6SDFHWRWKHÀRRU

cm
At least 250cm
300
st on
lea cti
At s tru
ob
the
e to
ac
Sp
Space to the obstruction

the
to n
At least 50cm

e
ac ctio
Sp stru
ob st
t lea
A cm
30

At least 30cm
Space to th
e wall

At least 50cm
n
c tio m
tru 0c Space to the
ob
s 20
st
he t le
a obstruction
tot A
a ce
Sp
Drainage pipe

2
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill
4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
Ɣ3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
Ɣ'RQ
WXVHXQTXDOL¿HGSRZHUFRUG

Selection of installation location


Basic requirement Indoor unit
Installing the unit in the following pla- 1. There should be no obstruction near air
ces maycause malfunction. If it is un- inlet and air outlet.
avoidable, please consult the local 2. Select a location where the condensat-
dealer: ion water can be dispersed easily and
1.The place with strong heat sources, won't affect other people.
, 3. Select a location which is convenient to
connect the outdoor unit and near the
or volatile objects spread in the air.
power socket.
2.The place with high-frequency 4. Select a location which is out of reach
devices (such as welding machine, for children.
medical equipment). 5. The location should be able to withstand
3.The place near coast area. the weight of indoor unit and won't incr-
4.The place with oil or fumes in the air. ease noise and vibration.
5.The place with sulfureted gas. 6. The appliance must be installed 2.5m
6.Other places with special circums-
tances. 7. Don't install the indoor unit right above
7.The appliance shall not be install- the electric appliance.
ed in the laundry. 8. Please try your best to keep way from
fluorescent lamp.
Outdoor unit

will not affect neighborhood.


2. The location should be well ventilated and dry, in which the outdoor unit
ZRQ
WEHH[SRVHGGLUHFWO\WRVXQOLJKWRUVWURQJZLQG
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
3
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.

air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its

8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.

Grounding requirement

grounding with specialized grounding device by a professional. Please make


sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in

4
Installation of indoor unit
Step one: choosing installation location
rm it with the client.

Step two: install wall-mounting frame


1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the

plastic expansion particles in the holes.


3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and

Step three: open piping hole


1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
09 K: 12K:
Wall Wall Wall Wall
Mark in the middle of it Level meter Mark in the middle of it Level meter
Space Space Space Space
to the to the to the to the
wall wall wall wall
above above above above
150mm 150mm 150mm 150mm

Left Right Left Right


ĭPP ĭPP ĭPP ĭPP
Rear piping hole Rear piping hole Rear piping hole Rear piping hole

18K: 24K:
Wall Wall Wall Wall
Mark in the middle of it Level meter Mark in the middle of it Level meter
Space Space Space Space
to the to the to the to the
wall wall wall wall
above above above above
150mm 150mm 150mm 150mm

Left Right Left Right


ĭ ĭ ĭPP ĭPP
Rear piping hole Rear piping hole Rear piping hole Rear piping hole

2SHQDSLSLQJKROHZLWKWKHGLDPHWHURIĭRUĭRQWKHVHOHFWHGRXWOHWSLSH
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.

5
Installation of indoor unit

Indoor outdoor
Note:
Ɣ3D\DWWHQWLRQWRGXVWSUHYHQWLRQDQG
WDNHUHOHYDQWVDIHW\PHDVXUHVZKHQ
opening the hole. ĭ
Ɣ The plastic expansion particles are 5-10 ĭ
QRWSURYLGHGDQGVKRXOGEHERXJKW
locally.

Step four: outlet pipe


1. The pipe can be led out in the 2. When select leading out the pipe
direction of right, rear right, left or from left or right, please cut off the
rear left. corresponding hole on the bottom
case.
left right

left rear left cut off


rear right the hole
right

1. Aim the pipe joint at the corresponding


bellmouth.
pipe joint union nut pipe

2. Pretightening the union nut with hand.

3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.

6
Installation of indoor unit
open-end Hex nut diameter Tightening torque (N.m)
wrench ĭ 15~20
union nut ĭ 30~40
ĭ 45~55
torque wrench pipe ĭ 60~65
ĭ 70~75
indoor pipe
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape. insulating pipe

Step six: install drain hose


1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
outlet pipe
2. Bind the joint with tape.
outlet drain hose
pipe
tape

Note: drain hose


Ɣ Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
Ɣ The plastic expansion particles are
insulating pipe
not provided.

Step seven: connect wire of indoor unit


screw
panel

1. Open the panel, remove the screw


on the wiring cover and then take
down the cover.

wiring cover

7
Installation of indoor unit

2. Make the power connection wire go cable-cross


through the cable-cross hole at the back hole
of indoor unit and then pull it out from
the front side.
power connection
wire

3. Remove the wire clip; connect the power


connection wire to the wiring terminal
according to the color; tighten the screw

with wire clip.


09、12K(for some model): 09、12、18、24K
(for some model):

N(1) 2 3 L1’ S L2’ G


white black red green white black red green
(blue) (brown) (yellow- (blue) (brown) (yellow-
green) green)

Outdoor unit connection Outdoor unit connection

1RWHWKHZLULQJERDUGLVIRUUHIHUHQFHRQO\SOHDVHUHIHUWRWKe actual one.

4.Put wiring cover back and then tighten the screw.


5.Close the panel.

Note:
Ɣ All wires of indoor unit and outdoor unit should be connected by a professional.

for a new one. Avoid extending the wire by yourself.

installation.
Ɣ)RUWKHDLUFRQGLWLRQHUZLWKRXWSOXJDQair switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.

28
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power connection pipe drain hose
band
cord and drain hose with the band.
indoor and
outdoor power cord
indoor unit gas
pipe

indoor power cord


liquid pipe
band 3. Bind them evenly.
drain hose
4. The liquid pipe and gas pipe should
be bound separately at the end.
2. Reserve a certain length of drain
hose and power cord for installation Note:
when binding them. When binding to Ɣ7KHSRZHUFRUGDQGFRQWUROZLUH
a certain degree, separate the indoor FDQ
WEHFURVVHGRUZLQGLQJ
power and then separate the drain Ɣ7KHGUDLQKRVHVKRXOGEHERXQG
hose. at the bottom.

Step nine: hang the indoor unit


1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor outdoor upper hook

wall pipe
sealing gum

lower hook of
wall-mounting frame

Note:
Ɣ'RQRWEHQGWKHGUDLQKRVHWRRH[FHVVLYHO\LQRUGHUWRSUHYHQWEORFNLQJ

29
Installation of outdoor unit
6WHSRQH¿[WKHVXSSRUWRIRXWGRRUXQLW
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.

Note:
Ɣ7DNHVXI¿FLHQWSURWHFWLYHPHDVXUHVZKHQ
installing the outdoor unit.
ƔMake sure the support can withstand at least
four times of the unit weight.
Ɣ7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVW
FPDERYHWKHÀRRULQRUGHUWRLQVWDOOGUDLQ
joint.
Ɣ)RUWKHXQLWZLWKFRROLQJFDSDFLW\RI:
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W at least 3cm above the floor
~16000W, 10 expansion screws are needed.

Step two: install drain joint 6WHSWKUHH¿[RXWGRRUXQLW


(Only for cooling and heating 1. Place the outdoor unit on the
unit) support.
1. Connect the outdoor drain joint into 2. Fix the foot holes of outdoor unit
the hole on the chassis, as shown in with bolts.
the picture below. foot holes
2. Connect the drain hose into the drain
vent.

drain vent chassis foot holes


outdoor drain joint
Drain hose

30
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han- 3. Pretightening the union nut with
dle of outdoor unit and then remove hand.
the handle.
pipe joint
screw

handle union nut

2. Remove the screw cap of valve and 4. Tighten the union nut with torque
aim the pipe joint at the bellmouth of wrench by referring to the sheet
pipe. below.
liquid pipe Hex nut diameter Tightening torque
(N.m)
liquid gas pipe ĭ a
valve ĭ 30~40
ĭ 4a
ĭ a
gas valve
ĭ a

1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the

、12K(for some model): 、12K(for some model): 18、24K:

L1’ S L2’ G
N(1) 2 3 L N L1’ S L2’ L2 L1 G
L1 L2 G
green white red black white green green white red black white green
(yellow- (blue) black (brown) (brown) (blue) (yellow- white black red green (yellow- (blue) black (brown) (brown) (blue) (yellow-
green) green) (blue) (brown) (yellow- green(yellow-green) green) green)
green) black(brown)
L2
white(blue)
L1
L N L2 L1
POWER
Indoor unit connection POWER Indoor unit connection POWER

Indoor unit connection

Note: the wiring board is for reference only,please refer to the actual one

31
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:

Ɣ1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQWKHGLVWDQFH

Step six: neaten the pipes


1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
wall
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the U-shaped curve
room.
drain hose

Note:
Ɣ The through-wal height of drain hose Ɣ6ODQWWKHGUDLQKRVHVOLJKWO\GRZ
shouldn't be higher than the outlet nwards. The drain hose can't be
pipe hole of indoor unit.
the drain hose
can't raise
upwards.

The drain hose can't be fluctuant


Ɣ The water outlet can't be placed
in water in order to drain smoothly.

The drain hose


can't be fluctuant
The water
outlet can't be
fluctuant
The water outlet
can't be placed
in water

32
Vacuum pumping
Use vacuum pump

1. Remove the valve caps on


the liquid valve and gas liquid valve piezometer Lo Hi
valve and the nut of refri-
gerant charging vent. gas valve
2. Connect the charging ho- refrigerant charging valve cap
se of piezometer to the vent
refrigerant charging vent nut of refrigerant
of gas valve and then co- charging vent
nnect the other charging
hose to the vacuum pump. vacuum pump
3. Open the piezometer com-
pletely and operate for inner hexagon
10-15min to check if the spanner
pressure of piezometer re-
mains in -0.1MPa. close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.

Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.

33
Check after installation
Ɣ&KHFNDFFRUGLQJWRWKHIROORZLQJUHTXLUHPHQWDIWHU¿QLVKLQJLQVWDOODWLRQ

Items to be checked Possible malfunction


+DVWKHXQLWEHHQLQVWDOOHG¿UPO\" The unit may drop, shake or emit noise.
Have you done the refrigerant leakage ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
test? (heating) capacity.
It may cause condensation and water
,VKHDWLQVXODWLRQRISLSHOLQHVXI¿FLHQW"
dripping.
It may cause condensation and water
Is water drained well?
dripping.
Is the voltage of power supply accord-
ing to the voltage marked on the It may cause malfunction or damaging
nameplate? the parts.

Is electric wiring and pipeline installed It may cause malfunction or damaging


correctly? the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the speci- It may cause malfunction or damaging
¿FDWLRQ" the parts.
Is there any obstruction in the air inlet ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
and outlet? (heating) capacity.
The dust and sundries caused during It may cause malfunction or damaging
installation are removed? the parts.
The gas valve and liquid valve of ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
connection pipe are open completely? (heating) capacity.

Test operation
1. Preparation of test operation
Ɣ7KHFOLHQWDSSURYHVWKHDLUFRQGLWLRQHU
Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW
2. Method of test operation
Ɣ3XWWKURXJKWKHSRZHUSUHVV212))EXWWRQRQWKHUHPRWHFRQWUROOHUWRVWDUW
operation.
Ɣ3UHVV02'(EXWWRQWRVHOHFW$872&22/'5<)$1DQG+($7WRFKHFN
whether the operation is normal or not.
Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQć , the air conditioner can’t
start cooling.
34
Configuration of connection pipe
1. Standard length of connection pipe
ƔPPP
0LQOHQJWKRIFRQQHFWLRQSLSHLVP
0D[OHQJWKRIFRQQHFWLRQSLSHDQGPD[KLJKGLfference.

Max length Max length


Cooling Max height Cooling Max height
of connec- of connec-
FDSDFLW\ difference FDSDFLW\ difference
tion pipe tion pipe

%WXK %WXK
   10
: :

%WXK %WXK
   10
: :

%WXK %WXK
   20
: :

%WXK %WXK
20 10  20
: :

%WXK %WXK
 10  20
: :

4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
Ɣ $IWHUWKHOHQJWKRIFRQQHFWLRQSLSHLVSURORQJHGIRUPDWWKHEDVLVRI
VWDQGDUGOHQJWK\RXVKRXOGDGGPORIUHIULJHUDQWRLOIRUHDFKDGGLWLRQDOP
of connection pipe.
Ɣ The calculation Pethod of additional refrigerant charging DPount (on the Easis
of liquid pipe):
$GGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW = prolonged length of liquid pipe ×
DGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQWSHUPHWHU
Ɣ%DVLQJRQWKHOHQJWKRIVWDQGDUGSLSHDGGUHIULJHUDQWDFFRUGLQJWRWKH
UHTXLUHPHQWDVVKRZQLQWKHWDEOH7KHDGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW
SHUPHWHULVGLfIHUHQWDFFRUGLQJWRWKHGLDPHWHURIOLTXLGSLSH6HHWKH
following sheet.

5
&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH
Additional refrigerant charging amount for R22, R407C, R410A and R134a

Diameter of connection pipe Outdoor unit throttle

Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m)

ĭ ĭRUĭ  20

ĭRUĭ ĭRUĭ  

ĭ ĭRUĭ 30 120

ĭ ĭRUĭ  120

ĭ _  

ĭ _  

36
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe E: Expand the port
Ɣ&RQ¿UPWKHSLSHOHQJWKDFFRUGLQJWR Ɣ([SDQGWKHSRUWZLWKH[SDQGHU
the distance of indoor unit and
outdoor unit. hard
mold
Ɣ&XWWKHUHTXLUHGSLSHZLWKSLSHFXWWHU expander
pipe

pipe
pipe cutter

leaning uneven burr


Note:
Ɣ$LVGLIIHUHQWDFFRUGLQJWRWKH
diameter, please refer to the sheet
below:

Outer diameter A(mm)


B: Remove the burrs (mm) Max Min
Ɣ5HPRYHWKHEXUUVZLWKVKDSHUDQG
prevent the burrs from getting into ĭ  1.3 0.7
the pipe. ĭ  1.6 1.0
pipe
shaper ĭ  1.8 1.0
ĭ  2.4 2.2
downwards
F: Inspection
Ɣ&KHFNWKHTXDOLW\RIH[SDQGLQJSRUW
If there is any blemish, expand the
C: Put on suitable insulating pipe port again according to the steps
D: Put on the union nut above.
Ɣ5HPRYHWKHXQLRQQXWRQWKHLQGRRU
smooth surface
connection pipe and outdoor valve;
install the union nut on the pipe.
improper expanding
union pipe

leaning damaged crack uneven


surface thickness
pipe the length is equal

37
Wired Controller
If the product you bought is equipped with wired controller, please
refer to the following introductions of wired controller.
1 Displaying Part

Fig1.1.1 Outline of wired controller

1.1 LCD Display of Wired Controller

Fig.1.1.2 LCD display

38
Wired Controller
1.2 Instruction to LCD Display
Table 1.1
No. Symbols Description

1 Swing function

2 Air exchange function (this function is yet unavailable for this unit).

3 Sleep function (Only sleep 1).

4 Each kind of running mode of indoor unit (auto mode)

5 Cooling mode

6 Dry mode

7 Fan mode

8 Heating mode

9 Defrosting function for the outdoor unit.

10 Gate-control function (this function is yet unavailable for this unit).

11 Lock function.

Shield functions (Button operation, temperature setting, On/Off operation,


12 SHIELD
Mode setting are disabled by the remote monitoring system.)
13 Turbo Turbo function state
Memory function (The indoor unit resumes the original setting state after
14 MEMORY
power failure and then power recovery).

15 It blinks under on state of the unit without operation of any button.

SAVE Energy-saving function (this function is yet unavailable for this unit).
16

17 Ambient/setting temperature value

18 E-HEATER Electric auxiliary heating function.

19 BLOW Blow function.

20 Timing value.
Quiet function (two types: quiet and auto quiet)
21 QUIET
(this function is yet unavailable for this unit).

39
Wired Controller
2 Buttons
2.1 Layout of Buttons

2.2 Functions of Buttons


Table 2.1
No. Name Function

1 Enter/Cancel Function selection and cancellation.


2 Ÿ ķ .Running temperature setting of the indoor unit, range:16~30oC.
6 ź ĸ .Timer setting, range:0.5-24 hr.
3 Fan Setting of the high/middle/low/auto fan speed.

4 Mode Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.

5 Function Switchover among the functions of Turbo/Save/E-heater/Blow etc..

7 Timer Timer setting.

8 On/Off Turn on/off the indoor unit


Press them for 5s under off state of the unit to enter/cancel the Memory
function(If memory is set, indoor unit after power failure and then power
4+2 Ÿ0RGH recovery will resume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
By pressing them at the same time under off state of the unit, will be
3+6 )DQź displayed on the wired controller for the cooling only unit, while will be
displayed on the wired controller for the cooling and heating unit.
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
2+6 Ÿź
case,any other buttons won’t respond the press. Repress them for 5s to quit
this state.

40
Wired Controller
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.3.1.1 indicates the “Off” state of the unit after power on. The state
shown in Fig.3.1.2 indicates the “On” state of the unit after power on.

Fig.3.1.1 “Off” State Fig.3.1.2 “On” State

3.2 Mode Setting


Under ON state of the unit, press the Mode to switch the operation modes as the following
sequence: Auto–Cooling–Dry–Fan–Heating.

3.3 Temperature Setting


Press Ÿor ź to increase/decrease the preset temperature. If pressing either of them
continuously, the temperature will be increased or decreased by 1°C every 0.5s,as shown in
Fig.3.3.1.
In the Cooling, Dry, Fan or Heating mode, the temperature setting range is 16°C~30°C.
In the Auto mode, the setting temperature is unadjustable.

Fig.3.3.1 Fig.3.4.1

41
Wired Controller
3.4 Fan Setting
Under the “On” state of the unit, press Fan and then fan speed of the indoor unit will change
circularly as shown in Fig.3.4.1.
Low Middle High

3.5 Timer Setting


Under on-state of the unit, Press Timer button to set timer off of the unit. Under off-state of the
unit, press Timer button to set timer on of the unit in the same way.
‡ Timer on setting:
Under off-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
Hour,with ON blinking. In this case, SUHVVŸ or ź button to adjust timer on and then press Timer to

‡ Timer off setting:


Under on-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
HourZLWK2))EOLQNLQJ,QWKLVFDVHSUHVVŸRUźEXWWRQWRDGMXVWWLPHURQDQGWKHQSUHVV Timer to

‡&DQFHOWLPHU
After setting of timer, if Timer button is pressed, LCD won’t display xx. Hour so that timer setting
is canceled.
Timer off setting under the “On” state of the unit is shown as Fig.3.5.1.

Fig.3.5.1 Timer off Setting under the “On” State of the Unit

42
Wired Controller
Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.

Fig.3.5.2 Timer on Setting under the “Off” State of the Unit


Timer range: 0.5-24hr. Every press of ŸRU ź will make the set time increased or decreased by
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.

43
Wired Controller
3.6 Swing Setting
Swing On: Press Function under on state of the unit to activate the swing function. In this case,

Swing Off: When the Swing function is on, press Function to enter the Swing setting
interface,with blinking. After that, press Enter/Cancel to cancel this function. Swing setting is
shown as Fig.3.6.1.

Fig.3.6.1 Swing Setting


Notes:
ķ . Sleep, Turbo or Blow setting is the same as the Swing setting.
ĸ . After the setting has been done, it has to press the key “Enter/Cancel” to back to the setting

44
Wired Controller
3.7 Sleep Setting
Sleep on: Press Function under the On state of the unit till the unit enters the Sleep setting

Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting
status. After that, press Enter/Cancel to cancel this function.
In the Cooling or Dry mode, the temperature will increase by 1°C after the unit runs under
Sleep1 for 1hr and 1°C after another 1hr.After that, the unit will run at this temperature.
In the Heating mode, the temperature will decrease by 1°C after the unit runs under Sleep 1 for
1hr and 1°C after another 1hr. After that, the unit will run at this temperature.
Sleep setting is shown as Fig.3.7.1.

Fig.3.7.1. Sleep Setting

45
Wired Controller
3.8 Turbo Setting
Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the
room temperature can quickly approach the setting value.
In the Cooling or Heating mode, press Function till the unit enters the Turbo setting status and

When the Turbo function is activated, press Function to enter the Turbo setting status and then
press Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.3.8.1.

Fig.3.8.1 Turbo Setting

46
Wired Controller
3.9 E-heater Setting
E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be

Once the wired controller or the remote controller enters the Heating mode, this function will be
turned on automatically.
Press Function in the Heating mode to enter the E-heater setting interface and then press
Enter/Cancel to cancel this function.
Press Function to enter the E-heater setting status, if the E-heater function is not activated,
and then press Enter/Cancel to activate it.
The setting of this function is shown as Fig.3.9.1 below:

Fig.3.9.1 E-heater Setting

47
Wired Controller
3.10 Blow Setting
Blow function: After the unit is turned off, the water in evaporator of indoor unit will be
automatically evaporated to avoid mildew.
In the Cooling or Dry mode, press Function till the unit enters the Blow setting status and then
press Enter/Cancel to active this function.
When the Blow function is activated, press Function to the Blow setting status and then press
Enter/Cancel to cancel this function.
Blow function setting is as shown in Fig.3.10.1

Fig.3.10.1 Blow Setting


Notes:
ķ . When the Blow function is activated, if turning off the unit by pressing On/Off or by the
remote controller, the indoor fan will run at the low fan speed for 2 min, with “BLOW” displayed on
the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly.
ĸ . Blow function is unavailable in the Fan or Heating mode.

48
Wired Controller
3.11 Other Functions
a. Lock
Upon startup of the unit without malfunction or under the “Off” state of the unit, press Ÿ and źat
the same time for 5s till the wired controller enters the Lock function. In this case, LCD displays .
After that, repress these two buttons at the same time for 5s to quit this function.
Under the Lock state, any other button press won’t get any response.
b. Memory
Memory switchover: Under the “Off” state of the unit, press Mode and Ÿ at the same time for
5s to switch memory states between memory on and memory off. When this function is activated,
Memory will be displayed. If this function is not set, the unit will be under the “Off” state after power
failure and then power recovery.
Memory recovery: If this function has been set for the wired controller, the wired controller after
power failure will resume its original running state upon power recovery. Memory contents: On/
Off, Mode, set temperature, set fan speed and Lock function.

4 Installation and Dismantlement


4.1 Connection of the Signal Line of the Wired Controller
Ɣ2SHQWKHFRYHURIWKHHOHFWULFFRQWUROER[RIWKHLQGRRUXQLW
Ɣ/HWWKHVLQJOHOLQHRIWKHZLUHGFRQWUROOHUWKURXJKWKHUXEEHUULQJ
Ɣ&RQQHFWWKHVLJQDOOLQHRIWKHZLUHGFRQWUROWRWKHSLQVRFNHWRIWKHLQGRRUXQLW3&%
Ɣ Tighten the signal wire with ties.
Ɣ The communication distance between the main board and the wired controller can be up to
20 meters ( the standard distance is 8 meters)

4.2 Installation of the Wired Controller


39&3LSH

1 2 3 4 5

Fig.4.1 Accessories for the Installation of the Wired Controller


Table 4.1
No. 1 2 3 4 5
6RFNHWER[ Soleplate of )URQW3DQHO
Screw Screw
Name embedded the Wired of the Wired
M4X25 ST 2.9X6
in the wall Controller Controller

49
Wired Controller

1 2 3 4

6 5
7

8 9 10
Fig.4.2
Fig.4.2 shows the installation steps of the wired controller, but there are some issues that need
your attention.
1) Prior to the installation, please firstly cut off the power supply of the wire buried in the
installation hole, that is, no operation is allowed with electricity during the whole installation.
2) Pull out the four-core twisted pair line from the installation holes and then let it go through
the rectangular hole behind the soleplate of the wired controller.

with screws M4X25.


4) Insert the four-core twisted pair line into the slot of the wired controller and then buckle the
front panel and the soleplate of the wired controller together.

CAUTION!
Please pay special attention to the followings during the connection to avoid the malfunction of
the air conditioning unit due to electromagnetic interference.
ķ . Separate the signal and communication lines of the wired controller from the power cord

50
Wired Controller
and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm,
otherwise the communication of the unit will probably work abnormally.
ĸ . If the air conditioning unit is installed where is vulnerable to electromagnetic
interference,then the signal and communication lines of the wired controller must be the shielding
twisted pair lines.

4.3 Dismantlement of the Wired Controller

1 2 3 4

5 Errors Display
If there is an error occurring during the operation of the system, the error code will be displayed
on the LCD, as show in Fig.5.1. If multi errors occur at the same time, their codes will be displayed
circularly.
Note: In event of any error, please turn off the unit and contact the professionally skilled
personnel.

Fig.5.1

51
Wired Controller
Table 5.1 Meaning of Each Error
Error Error
Error Error
Code Code
Return air temperature sensor open/
F1 Drive board communication error P6
short circuited
evaporator temperature sensor open/
F2 Compressor overheating protection H3
short circuited
Indoor unit liquid valve temperature
b5 Indoor and outdoor units unmatched LP
sensor open/short circuited
Indoor gas valve temperature sensor Communication line misconnected or
b7 dn
open/ short circuited expansion valve error
IPM temperature sensor open/short
P7 E7
circuited
Outdoor ambient temperature sensor
F3 Pump-down Fo
open/ short circuited
Outdoor unit condenser mid-tube
F4 Jumper error C5
temperature sensor open/short circuited
Discharge temperature sensor open/
F5 Forced defrosting H1
short circuited
Indoor and outdoor communication error E6 Compressor startup failure Lc

DC bus under-voltage protection PL High discharge temperature protection E4

DC bus over-voltage protection PH Overload protection E8


Compressor phase current sensing
U1 Whole unit over-current protection E5
circuit error
Compressor demagnetization protection HE Over phase current protection P5

PFC protection Hc Compressor desynchronizing H7

IPM Temperature Protection P8 IPM Current protection H5


Compressor phase loss/reversal
Over-power protection L9 Ld
protection
System charge shortage or blockage Frequency restricted/reduced with whole
F0 F8
protection unit current protection
Frequency restricted/reduced with IPM
Capacitor charging error PU En
current protection
Frequency restricted/reduced with high
High pressure protection E1 F9
discharge temperature
Frequency restricted/reduced with anti-
Low pressure protection E3 FH
freezing protection
Frequency restricted/reduced with
Compressor stalling LE F6
overload protection
Frequency restricted/reduced with IPM
Over-speeding LF EU
temperature protection
Drive board temperature sensor error PF Indoor unit full water error E9

AC contactor protection P9 Anti-freezing protection E2

Temperature drift protection PE AC input voltage abnormal PP

Sensor connection protection Pd Whole unit current sensing circuit error U5

DC bus voltage drop error U3 4-way valve reversing error U7

Outdoor fan 1 error protection L3 Motor stalling H6

Outdoor fan 2 error protection LA PG motor zero-crossing protection U8

52