Manual 7331 PI
Manual 7331 PI
Applications
Special features
■ Differential pressure measuring ranges from 0 ... 16 mbar
to 0 ... 40 bar [0 ... 0.23 to 0 ... 580 psi]
■ High working pressure (static pressure) up to 40 bar
[580 psi]
■ High overload safety up to 40 bar [580 psi]
■ Models 732.31 and 733.31: Case with safety level “S3” per
EN 837
■ All-welded media chamber
Description
These differential pressure gauges are made of highly The low-temperature version POLARgauge® allows opera-
corrosion-resistant stainless steel and feature an all-metal tion with ambient temperatures down to -70 °C [-94 °F].
media chamber to ensure long-term leak tightness (no
elastomer sealing elements). Casings with safety level “S3” are fitted with a non-splintering
window, a solid baffle wall between measuring system and
A high overload safety is achieved by the all-metal construc- dial and a blow-out back. In the event of a failure, the operator
tion and the close-fitting design of the diaphragm measuring is protected at the front side, as media or components can
element. only be ejected via the back of the case.
The use of high-quality stainless steel materials and the Scale ranges of 0 ... 16 mbar to 0 ... 40 bar [0 ... 0.23 to
robust design are geared to applications in the chemical 0 ... 580 psi] ensure the measuring ranges required for a wide
and process engineering industries. Thus the instrument is variety of applications.
suitable for liquid and gaseous media, also in aggressive
environments.
Case
Instrument pointer
Dial
Movement
Link
Diaphragm element
14503426.01
Media chamber, ⊕ side
⊖ side ⊕ side
■ Media chambers of the ⊕ and ⊖ side are separated by the diaphragm element
■ The pressure difference between ⊕ and ⊖ side leads to an axial pressure element deflection
Overload safety
Diaphragm elements have a relatively large actuating force and, due to the annular clamping of the element, they are less
sensitive to vibration in comparison with Bourdon tubes. Diaphragm elements can be subject to a higher overload of up to 10
times the full scale value, up to a max. of 40 bar, through load take-up points with metallic seating.
Overview of versions
Model Case design With case filling Low-temperature version
Safety level “S3” Safety level “S1” POLARgauge®
732.31 x Selectable
733.31 x x Selectable
732.51 x Selectable
733.51 x x Selectable
Basic information
Standard
Pressure measuring instruments for differential DIN 16003
pressure
→ For information on the “Selection, installation, handling and operation of pressure gauges”, see Technical information IN 00.05.
Nominal size (NS) ■ Ø 100 mm [4"]
■ Ø 160 mm [6"]
Measuring element
Type of measuring element Diaphragm element
Material
Span ≤ 0.25 bar [3.63 psi] Stainless steel 1.4571 (316 Ti)
Span > 0.25 bar [3.63 psi] NiCr alloy (Inconel)
Accuracy specifications
Accuracy class ■ 1.6
■ 1.0
■ 2.5
mbar psi
0 ... 16 1) 0 ... 400 0 ... 6 0 ... 100
0 ... 25 0 ... 600 0 ... 8 0 ... 150
0 ... 40 0 ... 1,000 0 ... 10 0 ... 160
0 ... 60 0 ... 1,100 0 ... 15 0 ... 200
0 ... 100 0 ... 1,200 0 ... 30 0 ... 250
0 ... 160 0 ... 1,600 0 ... 60 0 ... 300
0 ... 250 0 ... 2,500
0 ... 300 kPa
0 ... 1.6 1) 0 ... 160
bar 0 ... 2.5 0 ... 250
0 ... 0.25 0 ... 7 0 ... 4 0 ... 300
0 ... 0.4 0 ... 10 0 ... 6 0 ... 400
0 ... 0.6 0 ... 14 0 ... 10 0 ... 600
0 ... 1 0 ... 16 0 ... 16 0 ... 700
0 ... 1.6 0 ... 20 0 ... 25 0 ... 800
0 ... 2.5 0 ... 25 0 ... 30 0 ... 1,000
0 ... 4 0 ... 30 0 ... 40 0 ... 1,400
0 ... 6 0 ... 40 0 ... 60 0 ... 1,600
0 ... 100 0 ... 2,500
mbar psi
-16 ... 0 1) -8 ... +8 -15 ... 0 inHg -30 inHg ... +100
-25 ... 0 -10 ... +15 -30 ... 0 inHg -30 inHg ... +160
-40 ... 0 -20 ... +20 -30 inHg ... +15 -30 inHg ... +200
-60 ... 0 -30 ... +30 -30 inHg ... +30 -30 inHg ... +300
-100 ... 0 -50 ... +50 -30 inHg ... +60
-160 ... 0 -80 ... +80
-250 ... 0 -125 ... +125 kPa
-400 ... 0 -200 ... +200 -60 ... 0 -100 ... +100
-600 ... 0 -300 ... +300 -100 ... 0 -100 ... +150
-1,000 ... 0 -500 ... +500 -2 ... +4 -100 ... +200
-1,100 ... 0 -600 ... +400 -4 ... +6 -100 ... +300
-1,200 ... 0 -1,000 ... +600 -6 ... +4 -100 ... +400
-6 ... +10 -100 ... +500
bar -10 ... +6 -100 ... +700
-0.6 ... 0 -1 ... +5 -10 ... +15 -100 ... +900
-1 ... 0 -1 ... +9 -15 ... +15 -100 ... +1,000
-1 ... +0.6 -1 ... +15 -20 ... +40 -100 ... +1,500
-1 ... +1.5 -1 ... +24 -100 ... +60 -100 ... +2,400
-1 ... +3
1) Scale angle approx. 180°, with all other scale ranges the scale angle is 270°.
Other scales, e.g. with red mark, circular arcs or circular sectors, on request
→ Alternatively, adhesive label set for red and green circular arcs; see data sheet AC
08.03
Pointer
Instrument pointer With case filling Standard pointer, aluminium, black
Without case filling Adjustable pointer, aluminium, black
Mark pointer/drag pointer ■ Without
■ Mark pointer on bayonet ring, adjustable
0 ... 60 to 0 ... 250 mbar [0 ... 0.87 to 0 ... 3.6 psi] ■ 2.5 bar [36.3 psi] / 6 bar [87 psi]
■ 6 bar [87 psi] / 10 bar [145 psi]
0 ... 400 mbar [0 ... 5.8 psi] ■ 4 bar [58 psi] / 25 bar [363 psi]
■ 40 bar [580 psi] / 40 bar [580 psi]
0 ... 0.6 bar [0 ... 8.7 psi] ■ 6 bar [87 psi] / 25 bar [363 psi]
■ 40 bar [580 psi] / 40 bar [580 psi]
0 ... 1 bar [0 ... 14.5 psi] ■ 10 bar [145 psi] / 25 bar [363 psi]
■ 40 bar [580 psi] / 40 bar [580 psi]
0 ... 1.6 bar [0 ... 23.2 psi] ■ 16 bar [232 psi] / 25 bar [363 psi]
■ 40 bar [580 psi] / 40 bar [580 psi]
0 ... 2.5 to 0 ... 40 bar [0 ... 36.3 to 0 ... 580 psi] ■ 25 bar [363 psi] / 25 bar [363 psi]
■ 40 bar [580 psi] / 40 bar [580 psi]
→ Valve manifolds for an instrument hook-up, see “Accessories and spare parts”.
Size
EN 837-1 ■ 2 x G ¼, female thread
■ 2 x G ½ B, male thread
Restrictor ■ Without
■ ∅ 0.6 mm [0.024"], stainless steel
■ ∅ 0.3 mm [0.012"], stainless steel
Material (wetted)
Media chambers with process connection Stainless steel 1.4571 (316 Ti)
Venting of the media chambers Stainless steel 1.4571 (316 Ti)
Diaphragm element Span ≤ 0.25 bar [3.63 psi] Stainless steel 1.4571 (316 Ti)
Span > 0.25 bar [3.63 psi] NiCr alloy (Inconel)
Bellows Stainless steel 1.4571 (316 Ti)
Operating conditions
Medium temperature range ■ -20 ... +100 °C [-4 ... +212 °F]
■ -20 ... +120 °C [-4 ... +248 °F]
■ -20 ... +150 °C [-4 ... +284 °F]
Ambient temperature range ■ -20 ... +60 °C [-4 ... +140 °F]
■ -40 ... +60 °C [-40 ... +140 °F] 1)
■ -70 ... +60 °C [-94 ... +140 °F] for low-temperature version POLARgauge®
Storage temperature range -20 ... +60 °C [-4 ... 140 °F]
Pressure limitation
Steady Full scale value
Fluctuating 0.9 x full scale value
Ingress protection per IEC/EN 60529 ■ IP54
■ IP65 2)
Other versions
■ Oil- and grease-free
■ For oxygen, oil- and grease-free
■ Silicone-free
■ Per NACE 1) MR 0175 / ISO 15156, use in H₂S-containing environments in oil and gas production
■ Per NACE 1) MR 0103 / ISO 17945, metals resistant to sulfide stress cracking
■ With pre-volume deflagration flame arrester 2) for connection to zone 0 (EPL Ga); model 910.21; see data sheet AC 91.02
Optional approvals
Logo Description Region
EU declaration of conformity European Union
ATEX directive
Hazardous areas
Gas II 2G Ex h IIC T6 ... T1 Gb X
Dust II 2D Ex h IIIC T85 °C T450 °C Db X
Certificates (option)
Certificates
Certificates ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy)
■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication
accuracy)
Recommended recalibration interval 1 year (dependent on conditions of use)
14503466.01
Mounting holes
100 ≤ 0.25 bar [3.63 psi] G¼ 23.5 59 101 99 140 17.5 160 90 2.70
[4"] [0.96] [2.32] [3.98] [3.90] [5.51] [0.69] [6.30] [3.54] [5.95]
> 0.25 bar [3.63 psi] G¼ 23.5 59 101 99 78 17.5 170 87 1.90
[0.96] [2.32] [3.98] [3.90] [3.07] [0.69] [6.69] [3.43] [4.12]
160 ≤ 0.25 bar [3.63 psi] G¼ 23.5 59 161 159 140 17.5 190 120 3.40
[6"] [0.96] [2.32] [6.34] [6.26] [5.51] [0.69] [7.48] [4.72] [7.5]
> 0.25 bar [3.63 psi] G¼ 23.5 59 161 159 78 17.5 200 117 2.40
[0.96] [2.32] [6.34] [6.26] [3.07] [0.69] [7.87] [4.61] [5.29]
100 ≤ 0.25 bar [3.63 psi] G¼ 15.5 49.5 101 99 140 17.5 160 90 2.70
[4"] [0.61] [1.95] [3.98] [3.90] [5.51] [0.69] [6.30] [3.54] [5.95]
> 0.25 bar [3.63 psi] G¼ 15.5 49.5 101 99 78 17.5 170 87 1.90
[0.61] [1.95] [3.98] [3.90] [3.07] [0.69] [6.69] [3.43] [4.12]
160 ≤ 0.25 bar [3.63 psi] G¼ 15.5 49.5 161 159 140 17.5 190 120 3.40
[6"] [0.61] [1.95] [6.34] [6.26] [5.51] [0.69] [7.48] [4.72] [7.5]
> 0.25 bar [3.63 psi] G¼ 15.5 49.5 161 159 78 17.5 200 117 2.40
[0.61] [1.95] [6.34] [6.26] [3.07] [0.69] [7.87] [4.61] [5.29]
Dimensions in mm [in]
Representation with mounting bracket for wall or pipe mounting and fitted 5-valve manifold
14503466.01
≤
Ordering information
Model / Nominal size / Scale range / Scale layout (linear pressure or square root incrementation) / Max. working pressure
(static pressure) ... bar / Process connection / Connection location / Options
© 10/2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
09/2021 EN