0% found this document useful (0 votes)
103 views3 pages

MINT1400A: Medical - Universal Input Power Supply

This document provides specifications for the MINT1400A 400W single output power supply. It can provide up to 400W of power with 12V, 24V, 28V or 48V outputs and has universal 85-270VAC input. The supply measures 3.94” x 7” x 1.58” and has overvoltage, overload and overtemperature protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views3 pages

MINT1400A: Medical - Universal Input Power Supply

This document provides specifications for the MINT1400A 400W single output power supply. It can provide up to 400W of power with 12V, 24V, 28V or 48V outputs and has universal 85-270VAC input. The supply measures 3.94” x 7” x 1.58” and has overvoltage, overload and overtemperature protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

MINT1400A

400W Single Output Series


Medical – Universal Input Power Supply 2 Year Warranty
•Compact 3.94” x 7” x 1.58”, 1U compatible
•9.5 W/in³
•Up to 250W Convection Rating
•Efficiency up to 91%
•12Vdc to 48Vdc outputs, up to 400W
•Remote ON/OFF
•Safety approved to Medical and ITE Standards
• EN/IEC/UL60601-1 and CSA 601.1
•CSA/EN/IEC/UL60950-1, 2nd Edition
•Compliant to EN55011/22 Conducted Noise, Class B
•RoHS Compliant – Category 6

Specifications All Specifications are typical at nominal input, full load at 25°C unless otherwise stated.
AC Input 85-270VAC, 47-63 Hz single phase Turn On Time 500mSec maximum
Input Current 120VAC: 4.2A, 230VAC: 2.1A Hold-up Time 20 ms at 400W
Inrush Current Active circuit, 37A max Overvoltage Protection See chart
Input Fuses F1, F2: 6.3A Overload Protection Cycling type, 470W typical
Power Factor 0.99 typical, 0.96 minimum Overtemperature Protection Provided on all models, auto-
Efficiency Typical 88% @ 120VAC, 91% @ 240VAC recovery. See page 2 for cooling information
Remote Sense Compensates for up to 500mV Switching Frequency Output: 170kHz ± 8kHz;
drop on output leads PFC: 90kHz, ± 8kHz; Bias: 100kHz, ± 6 kHz
Output Power 400W with fan cooling. See derating chart for other Safety Standards Medical: EN/IEC/UL 60601-1, CSA 601.1
conditions. Peak: 450W for 1 min., 10% duty cycle ITE: CSA/EN/IEC/UL 60950-1, 2nd Edition
Ripple and Noise 1% pk-pk max., 20MHz BW, differential mode Isolation Input-Output: 4000VAC,
Input-Ground: 1500VAC, Output-Ground: 500VAC
Output Voltages See chart. Voltages adjustable +/- 5% Earth Leakage Current 100µA at 120VAC, 60Hz Normal.
400µA at 264Vac, 60Hz SFC.
Total Regulation See chart Operating Temperature 0° to 70°C, refer to derating
curve for ratings >40°C
Minimum Load Not required Storage Temperature -40 to +85°C
Transient Response 500µs to 1%, 0.2A/µs, 3.5% Deviation Relative Humidity 5% to 95%, non-condensing
Shock and Vibration Shock: MIL-STD-810E, 516.4 part IV Altitude Operating: -500 to 10,000 ft.
Vibration: 5Hz – 500Hz, 2.5 Grms Non-Operating: -500 to 40,000 ft.

Model Number Key


MINT 1 400 A 12 10 L 01
01 = Standard Model, 02 and higher indicates a m odified m odel.
"L" = Input Connector - EBY P/N 5002-03-N-12
"10" = Output Connections - Bus Bars w ith #10 screw s
Output Voltage: "12" = 12V output, "24" = 24V output, etc.
Model Configuration: "A" = Original Configuration; "C" = Optional fan cover included
Output Pow er (Watts) - "400" = 400W
# of Outputs
Product Fam ily: "M" = Medical, "I" = Internal, "NT" = New Technology

______________________________________________________________________________________________________________________________ 1 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com
MINT1400A
400W Single Output Series
Medical – Universal Input Power Supply 2 Year Warranty

Output Parameters
Model Output Output Current Ripple Total
Number Volts (V) Fan Cooled Convection & Noise Regulation

MINT1400A1210L01 12V 33.0A 21.0A 1% 2%


MINT1400A2410L01 24V 16.7A 10.4A 1% 2%
MINT1400A2810L01 28V 14.3A 8.9A 1% 2%
MINT1400A4810L01 48V 8.30A 5.2A 1% 2%

Signals
Inhibit: DC OK:
TTL LOW to inhibit HIGH when output is >90% of nominal
PS Off: Fan Output:
TTL HIGH to inhibit 12Vdc @ 250 mA.
Pwr OK 5V Standby Voltage:
TTL HIGH when AC is OK, 100-200 mS delay. Always on, up to 100mA.
Pwr OK
PF LOW 4 mS warning before loss of output regulation.

EMI/EMC Compliance
Conducted Emissions EN55011/22 Class B
Radiated Emissions EN55011/22 Class A
Voltage Fluctuations EN61000-3-3, complies
Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity EN61000-4-3, 3V/m.
EFT/Burst Immunity EN61000-4-4, 2kV/5kHz..
Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
Voltage Dip Immunity EN61000-4-11 criteria A @ 250 Watts or less.
Line Frequency Harmonics EN61000-3-2, Class A

Output Power Derating Curve

MINT1400 Output Power Derating Chart


450
Output Power (Watts)

400
350 Note: For convection cooling, the
300 power supply is required to be
250 mounted on a heatsink or system
200 chassis with a minimum of 150 in² of
Fan Cooled surface area.
150
Convection
100
50
0
0 10 20 30 40 50 60 70
Ambient Temperature (deg C)

______________________________________________________________________________________________________________________________ 2 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com
MINT1400A
400W Single Output Series
Medical – Universal Input Power Supply 2 Year Warranty

Outline Drawing & Connector Information

Connector Information

Data Sheet © 2011 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. Rev. 6-7-2013
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.

______________________________________________________________________________________________________________________________ 3 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com

You might also like