Quotation / Offer No.
Charact. curves
NT 125-250/01 Proj ect ID
Charact. curves acc. DIN EN ISO 9906 Class 2 Item:
Admissible minmum capacity 10 % * Q(opt) at continous operation [Link]:
Rem arks:
Attention! Impeller is turned down on angle at diametre D<=199 mm acc. document 134-190.
Created by Date
GR-B, - 2012-12-11
Power data ref erred to: Water, pure
Q H P Vis Temp Density rated Torque Speed
1) 1,0 mm²/s 20,0 °C 1,00 kg/dm³
2) 1450 1/min
NPSH-value without safety margins
Head
[m]
24 60%
70% 74%
78%
22 81%
Eff.
20 82,8%
18
16 83,5%
14
79,5%
12
60%
10 Ø 270
68,5%
8
Ø 250
6
Ø 230
4
2 Ø 200
Shaft power P2 Ø 270 (P2)
[kW]
16
12
8 Ø 200 (P2)
4
NPSH-values Ø 200
[m] Ø 270
8
6
4
2
Efficiency
[%]
60 Ø 270
40
20 Ø 200
0 40 80 120 160 200 240 280 320 360 [m³/h]
Flow
V2.0.7 Curve number: 125 01250 0114 Page 1
Quotation / Offer No.
Charact. curves
NT 125-250/01 Proj ect ID
Charact. curves acc. DIN EN ISO 9906 Class 2 Item:
Admissible minmum capacity 10 % * Q(opt) at continous operation [Link]:
Rem arks:
Attention! Impeller is turned down on angle at diametre D<=199 mm acc. document 134-190.
Created by Date
GR-B, - 2012-12-11
Power data ref erred to: Water, pure
Q H P Vis Temp Density rated Torque Speed
1) 1,0 mm²/s 20,0 °C 1,00 kg/dm³
2) 2900 1/min
NPSH-value without safety margins
Head
[m]
60 50%
60%
65%
55
70%
50
Eff.
45 72,7%
40
66%
35
61,2%
30 60%
25
50%
20
15
Ø 220
10
Ø 200
5 Ø 180
Shaft power P2
[kW] Ø 220 (P2)
60
Ø 180 (P2)
40
20
NPSH-values Ø 220
[m] Ø 180
20
15
10
Efficiency
[%]
60
40
Ø 220
20
Ø 180
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 [m³/h]
Flow
V2.0.7 Curve number: 125 01250 0129 Page 2