7 Operating instructions
7.1 Initial start-up
Warning
A ‘The operator must apply all relevant Safety precautions.
A ‘Switch off the voltage before making any adjustment.
Outdoorialtitude operation
Ifthe compressor is installed outdoors or ifthe air inlet temperature can be below freezing point, precautions
must be taken. In this case, and also if operating at high altitude, consult the Customer Centre,
Movingllifting
‘The compressor can be moved by a lift truck using the slots in the frame. Make sure that the forks protrude
from the other side of the frame. The compressor can also be lifted after inserting beams in the slots. Make
sure that the beams cannot slide and that they protrude from the frame equally. The chains must be held parallel
to the bodywork by chain spreaders in order not to damage the compressor. The lifting equipment must be
placed in such a way that the compressor is lifted perpendicularly. Lift gently and avoid twisting,
General preparations
Fill the compressor element at initial start-up
66 '899711901-02V01—
Instruction book STA etn Mit ai yar 74 Atlas Copeo
—
‘Install the compressor, see the sections Dimension drawing, Installation proposal and
Electric cable size.
Stick labels near the control panel to warn the operator that:
‘+ the compressor may start automatically after a voltage failure
+ the compressor is automatically started and stopped
+ the compressor may be remotely controlled
‘A number of VGI (Volalile Corrosion Inhibitor) plates are provided inside the bodywork to
protect the compressor against corrosion. Remove the plates.
Ifthe compressor has not run for the past 6 months, itis required to improve the lubrication.
of the compressor element before starting. Fill up the compressor element as described
in section Oil change (paragraph: Filling the compressor element with oil)
Check that the compressor is filled with oil, the pointer of the oil level indicator should be
inthe green range (see the section Oil change)
Protection during transport
Transport fixtures
~The gear casing supports, motor support and air receiver supports are secured to the
the vibration dampers during transport
2 {rom the gear casing supports and the motor support.
3 Remove the brackets fited next tothe air receiver supports. _—
§99711901-02v01 67Instruction book STX Nonway Ofshore Brevik, yard, 734 Atlas Copco
7.2 Before starting
Warning
[_ A The operator must apply all relevant Safety precautions, -
ithe walersyiom was aed ae sree ran vals we cone.
Control panel
1 2 a4
= = 1||®
© | |@
_ = kal
)) aOn\ =
2 9 8 768 3
[Sen “Thation :
k Switch on the vottage. Voltage on LED (6) hts up
2 Close the condensate drain valves (see the section Cooling and condensate system)
3 | Open the air outlet valve. -
4 Check the oll level indicator (see the section Oil change), The pointer shouldbe inthe
green range or orange range |
ie Opn The waar st ated 2 he War gO) |
7.3. Start Request (function)
Function
Upon @ start command (either local or remote) the automatic operation contaet will close. This signal will be
used by the customer to start a generator. A feedback signal from the generator (closed = ready) is connected
(oan additional Digital input on the Mk IV module (programmed as permissive start function). When this
input is OK within a certain time the unit will start.
Contact connected between 1X6 : 53-63
At standstill
+ Contact "start request" closed : compressor ean start - no general warning
* Contact "start request” open : compressor will NOT start - general warning
> general warning disappears when contact closes
89971 1901-02V01 6—«
Atlas Copeo
=a
‘SIX Norway Offshore Brevik, yard 734 Instruction book
Electric cabinet
Step.
1
Start up
Action
Check that the electrical connections correspond to the local codes. The installation must
be earthed and protected by fuses in all phases. An isolating switch must be fitted.
Check the wires on transformers for correct ti
Check the setting of the circuit breakers (see the section Settings of circuit breakers).
Check that overioad relay (F21) is set for automatic resetting and check its setting (see
the section Setting of overload relay and fuses),
Action
‘Check that the cooling water drain valves (customers installation) in the inlet and outlet
lines are closed.
Check that the water shut-off valves (custo
Open the water regulating valve
1°S installation) are open.
id check for water flow.
Manual condensate drain valve
Retion
Close the drain valves (see the section Gooling and condensate system),
‘Switch on the voltage.
Start the compressor and stop it immediately. Check the rotation direction of the drive
‘motor while the motor is coasting to a stop. To determine the rotation direction of the motor,
lock at the fan through the grating at the non-drive end of the motor. The correct rotation
direction is indicated by an arrow on the gear casing.
ifthe rotation direction is wrong, press the emergency stop button, switch off the voltage
and reverse two incoming electric lines.
Run the compressor for a few minutes and check that itis operating normally
899711901-02v01como
ftlas Copco ‘STX Nonay Ofshore Brevis yard.734 Instruction book
=
Pressing the "start" button (local or remote)
+ Contact *start request” closed : contact "automatic operation* closes and compressor starts immediately
*+ Contact "start request” open : contact “automatic operation” closes and compressor waits until "start
request” i closed - general warning
-> customer has 60 seconds to close the contact (min 0 sec - actual 60 sec - max 255 sec)
> if eontact is not closed after pre-set time : general shut-down (start failure)
--> if contact is closed during this pre-set time : compressor starts and general warning disappears
Compressor running :
+ Contact"
tart request” closed or open : no general warning,
Compressors stops :
+ Same situation as during standstil
7.4 Starting
Warning
[A [emesis no -
Control panel
12 14
mone |®D
° is| |@
~ U3
ao 5
onl pe
ae nae -
i Tras a aa (i oT SSIS adel condi
Sarien eam aes .
7 eyes scons a Grog) GSSGES Hak Bede
| ____| message onaeplay 2) changes fom Automatcally unloaded’ fo ‘AUtomaialy loaded”,
70 $9971 1901-02V01Instruction book 'STX Norway Offshore Brevik, yard734 Vilas
Step Action
3 Reguiate the cooling water flow with the compressor running loaded. Adjust the water flow
to obtain the most suitable air temperature at the outlet of the compressor elements. The:
temperature must be between 2 and approx. 7 °C (4 and approx. 13 °F) above the relevant)
temperature in the diagram.
‘somren N
B
\ 120
. NO 110
+S 100
7 \ Too
A 80
oy 70
4 60
30- \ NON
- 40
20
}-30
10
* 20
°. t
{10
2 40 69 80 100
D 6 B1012 1620
c
Minimum alfowable air temperature at oulet of the compressor element(s)
Reference Name -
A Ar inlet temperature in “C _ -
8 ‘Condensation temperature in °C - -
c | Effective working pressure in bar
D ~ [Relative air hurtin % ~
Example
Ambient temperature 20 °C.
Relative humidity 100%,
Workirg pressure 10 bar(e)
‘The minimum allowable temperature at the outlet of the compressor elements is 68 °C.
Regulate the cooling water flow to obtain a temperature between 70 and approx. 75 °C at the outlet of the
compressor elements.
Attention
$99711901-02V01 mn=
‘Atlas topeo 'STX Norway Offshore Brovk,yara.734
Instruction book
+ For optimum operation, the cooling water outlet temperature must never exceed the max. value.
+ Consult Atlas Copco if condensate should be formed during frequent unloadi
7.5 During operation
Warning
[ / ‘The operator must apply all relevant Safety precautions,
‘The operator should immediately stop the machine in case of oil leaks internally in the
machine as wel as externally and consult a competent technician to resolve the cause.
‘The machine should not be restarted before the problem has been remedied
Control panel
Eoronon
®
@
pay
Control pane! of MAIV regulator
1. When the automatic operation LED (8) is lit, the stating and stopping of the motor is controlled
automatically.
Check the readings on display (2).
Tounload the compressor manually, press the “Unload” key (5). To putthe compressor back into automatic
operation, press the “Load” key (5).
[ g Ifthe compressor is stopped, it may start automatically. |
7.6 Checking the display
Warning
Before carrying out any maintenance, repair work or adjustment, stop the compressor,
A press the emergency stop button and switch off the voltage. Close the air outlet valve and.
‘open the manual condensate drain valve.
72 899711901-02V01vsanalon vox Tincna Owe mwa oe
falasepece
Control panel
; a4
comm | |D
> Came |@
eo oy
—. ~BA\ =
. tes
Sep ion
nen ah daly Tr eadnge and mesapes, Neral te wa pay
Fe ee rst ensure, Bo sas ol compressor an the
ann ea yn tatoe dol
3 ase ete Jepayandamety tw problem alurm LED Os War fasting
3 ae sevice reatape Ta sence a lent hes been exceeded oF
The Spay wil shoo seri est23e nas ecenolcoeded. Gay extte sores
Haseena te component an set erent
=
7 a ino el Gover usb eng e aow down Rey fom te
main screen,
Example of the main menu
“Status data
“Measured Data”
“Counters”
"Mainscreen"
(FA
\F2 Fa
Example of the main display
Main display
“Compressor outlet [eobar —
“Automatically loaded”
“Menu!
{ "Unload"
Fi
F2 FS
‘$9971 1901-02v01
4el
Atlas Copco ‘STX Nonray Ofshore Brevik, yard.734
Instruction book
ee
7.7 Manual loading/unloat
Control panel
©®@
SRS
Control panel of Elektronikon MEIV regulator
Example of the main display
Main display
“Compressor outlet” 6.0 bar I
“Automatically loaded” _ 7 v
"Menu" “Unload
ic F2 Fa
Automatic operation
Normally, the compressor runs in automatic operation, ie, the electronic regulator loads, unloads, stops and
restarts the comptessor automatically, LED (8) is then lit.
Manually unloading
Press “Unload” key (F3), LED (8) goes out. The message “Manually Unloaded” appears on the display. The
compressor remains running unloaded unless it is loaded again manually
Manually loading
Press “Load” key (F3), LED (8) lights up. The command “Load” does not force the compressor into loaded
condition, but it will switch the compressor to automatic operation again; the compressor will be loaded if
the air net pressure drops below the programmed level.
74 899711901-02V01Instruction book
'STXNowway Offshore Brevik, yard. 734 ftlas Copeo
7.8 Stopping
Important
4
Control panel
Reference
‘After pressing stop bution (8), the compressor will run unloaded for 30 seconds. The
compressor stops after this period. A start command during this period is ignored
‘Afer stopping, the compressor is prevented from restarting within a programmable tme
(20 seconds). A start command given during this minimum stop time will be memorised.
the automatic operation LED lights up. The compressor will start when the minimum stop,
time has elapsed |
1 2 34
—
ho
|\O O0@
—- wa
!
\
82 ° e o7es 3
Control panel
‘compressor runs unloaded for 30 seconds and then stops.
1
Press stop button (8). LED (8) goes out. The message ‘Programmed stop” appears The
To stop the compressor in the event of an emergency, press button (S2). Alarm LED (7)
blinks. After remedying the fault, unlock the button by pulling it out
Oper te aaidenens avalon
Close the air outlet valve,
‘Switch off the voltage. |
Close the water shutoff vaves “I
ifthe compressor is installed in a room where freezing temperatures are expected, drain
the cooling system by opening the drain valves in the water inlet and outlet pipes
{customers installation).
7.9 Taking out of operation
Disconnecting the compressor
[ Stop
At the end of the service life of the compressor, proceed as follows:
Action
1
‘Stop the compressor and close the air outlet valve.
$99711901-02v01