Magnetic Float Operated Guided Level Transmitter
‘VEKSLER’ make MLI-19 used for continuous level indication and control for any
liquid that is chemically compatible with its wetted parts. It has an accuracy upto
0.5% FSD and can be used upto 90 deg C temp. & 20 kg/cm2 pressure. The
maximum length that can be supplied is 3 meters. It is available in different
material of construction like SS304, SS316, PVC and PP & with different Float
sizes. The enclosure is IP56/IP65/Ex-proof Gr IIA & IIB approved to suit various
service condition & application. It is factory calibrated and requires no calibration
at site. It is simple to install and is supplied with 3" NB ASA150#Flange.
Features
Top mounted type and is used for continuous level indication
Resistance/ Reed switch Contact Chain, Max. 3 Mtr Length
4-20 mA O/P-2, 3 or 4 wire /0-10 VDC output or as required
Application includes tanks of Oil, Fuels, Chemicals, Pure/Industrial Water,
Ship/LPG, Critical Inventory, Pharmaceutical Plants etc.
3 " NB MS flange drilled to ASA 150# as standard and other connection on
demand
Accuracy : 1 cm, 90 Deg C max Temperature, 20 Bar max Pressure
SS 304/316/PVC/PP/PTFE Guide Tube & Float
Adjustable Multiple Alarm Contacts on Electronic Controller
IP56/IP65/Ex-Proof Gr IIA & IIB approved enclosure
Top Mounting with 80 NB Flanged Connection
Customized Length upto 3 Mtrs
Applications: Tanks of Oils, fuels, chemicals, Pure/Industrial water, ship/LPG tanks, critical Inventory,
Pharmaceutical plants etc. Construction&Operations It comprises of a level transducer and a
transmitter. The transducer consists of a float & guide tube assembly in non-magnetic material to
achieve undisturbed flux. A chain of closely spaced glass encapsulated reed switches & a resistor is
placed inside the tube. During rise and fall of liquid level, the float moves & actuates a reed switch in
the chain, through a magnet system within it and develops a proportional voltage. The operation is
similar to a sliding resistance potentiometer. The sensed voltage is fed to the transmitter for conversion
to a signal of 4-20 mA, which can be either processed through a display unit to give a digital indication,
with or without alarm set points or employed for use with Process Indicator, PLC/DCS or Recorders.
Magnetic Float Operated Guided Level Transmitter
Specifications A) LEVEL
TRANSDUCER
Measuring Range : 3 meters max.
Accuracy : +/- 10 mm
Installation : Top Mounted
Terminal Enclosure : Cast Aluminium, weather proof to IP 56/65 and Ex. Proof For Gr. II A & II B/
Gr IIC
Conduit Connection : Brass, ¾" ET or ½" NPT
Wetted Parts : SS304, SS316 or PP
Float : SS 316, Magnetic
Process Connection : Flanged to BS/ ANSI/ ASA/DIN
Min Liquid Sp. Gr. : 0.7
Max. Temperature : 60ºC (PP) / 90ºC (SS)
Test pressure : 3 kg/cm² (PP)/ 10 Kg/cm² (SS)
B) TRANSMITTER (INTEGRAL WITH TRANSDUCER)
Wiring System : 2 wire/ 3 wire
Input : variable resistance from transducer
Output : 4 - 20 mA/0 - 10 VDC
Max. Load : 400 ohms
Supply : 24 VDC