0% found this document useful (0 votes)
295 views16 pages

Calculation For Nozzle Load

1. The document provides calculations to check allowable loads on compressor nozzles based on API-617 standards. 2. Key parameters like forces, moments, areas, and resultant forces and moments are calculated for individual nozzles and combined nozzles. 3. The results are compared against limits specified in API-617 to check if the actual values are below the allowed thresholds.

Uploaded by

Dharmesh Sutar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
295 views16 pages

Calculation For Nozzle Load

1. The document provides calculations to check allowable loads on compressor nozzles based on API-617 standards. 2. Key parameters like forces, moments, areas, and resultant forces and moments are calculated for individual nozzles and combined nozzles. 3. The results are compared against limits specified in API-617 to check if the actual values are below the allowed thresholds.

Uploaded by

Dharmesh Sutar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Vent Dia 6 152.4 B.

C Dia 2

Fx 3121 Fx 62
Fy 1013 Fy 109
Fz -1683 Fz -395
Mx 0 Mx -8
My 0 My -4
Mz 0 Mz 0

Fr 3687.723 Fr 414.4273
Mr 0 Mr 8.944272

Fr+1.09Mr<54.01D Fr+1.09Mr<54.01D

3688.813 8231.124 415.5173 2743.708

2 Fx = 4132
Fy = 5086
Fz = -2844
50.8 DIS 6 152.4

Fx 949
Fy 3964
Fz -766
Mx 0
My 0
Mz 0

Fr 4147.367
Mr 0

Fr+1.09Mr<54.01D

4148.457 8231.124
Inch mm
Vent Dia 6 152.4

Fx = 3121
Fy = 1013
Fz = -1683
Mx = 0
My = 0
Mz = 0

(I) check resultant forces on indicidual


Nozzles

Fr = √ (Fx)2+(Fy)2+(Fz)2 = 3687.723
Mr = √ (Mx)2+(My)2+(Mz)2 = 0

Fr+1.09Mr ≤ 54.01 De

3687.723 ≤ 8231.124

(II) Check Combined resultant forces on Nozzles

Fcx = Fx + Fy + Fz Fcx = 4132


Fcy = 5086
Fcz = -2844
Mcx = -8
Mcy = -4
Mcz = 0

Fc = √ (Fx)2+(Fy)2+(Fz)2 = 7143.469
Mc = √ (Mx)2+(My)2+(Mz)2 = 8.944272

Nominal Nozzle 1 Area = ∏ (r)2 = 18232.22


Nominal Nozzle 1 Area = ∏ (r) 2 = 2025.802
Nominal Nozzle 1 Area = ∏ (r) 2 = 18232.22
Sum Of Nozzle Area = 38490.25

Dc = √ 4 * (Total NozzleArea ) / ∏ = 221.4321


Fc + 1.64 Mc ≤ 40.4 Dc
7158.1380711153 ≤ 8945.855

(III) Check the component of combined force on Nozzles

Fx = 16.1Dc = 3565.056
Fy = 40.5Dc = 8967.999
Fz = 32.4Dc = 32.4
Mx = 24.6Dc = 5447.229
My = 12.3Dc = 2723.614
Mz = 12.3Dc = 2723.614
B.C Dia 2 50.8 DIS

Fx 62 Fx
Fy 109 Fy
Fz -395 Fz
Mx -8 Mx
My -4 My
Mz 0 Mz

Fr 414.4273 Fr
Mr 8.944272 Mr

Fr+1.09Mr<54.01D Fr+1.09Mr<54.01D

415.5173 2743.708 4148.457


6 152.4 DIS 10 254

949 Fx 949
3964 Fy 3964
-766 Fz -766
0 Mx 0
0 My 0
0 Mz 0

4147.367
0

Fr+1.09Mr<54.01D

8231.124
A

Legands
Data input Nozzle 1 : Vent
Observation criteria Ø=Dn=
Ø=Dn=

Fx =
Fy =
Fz =
Mx =
My =
Mz =

(I) Check resultant FORCES and MOMENTS on


individual Nozzles against limit 1 , paragraph E.2a of
API 617

Fr = √ (Fx)2+(Fy)2+(Fz)2 =
Mr = √ (Mx)2+(My)2+(Mz)2 =

Fr + 1.09 Mr ≤

4649.971 ≤

(II) Check combined resultant FORCES and


MOMENTS on Nozzles against limit 2 , paragraph
E.2b of API 617

Sum of X-compnents of force on each nozzle Fx =


Sum of Y-compnents of force on each nozzle Fy =
Sum of Z-compnents of force on each nozzle Fz =
Sum of X-compnents of moment on each nozzle Mx =
Sum of Y-compnentsof moment on each nozzle My =
Sum of Z-compnents of moment on each nozzle Mz =

Fc = √ (Fx)2+(Fy)2+(Fz)2 =
Mc = √ (Mx) +(My) +(Mz)
2 2 2 =

Nominal Nozzle 1 Area = ∏ (r)2 =


Nominal Nozzle 2 Area = ∏ (r)2 =
Nominal Nozzle 3 Area = ∏ (r)2 =
Nominal Nozzle 4 Area = ∏ (r)2
Sum Of Nozzle Area =

Dc = √ 4 * (Total NozzleArea ) / ∏ =

Fc + 1.64 Mc ≤
9038.0273 ≤

(III) Check the component of combined force and


moments on Nozzles

Fx = 16.1Dc =
Fy = 40.5Dc =
Fz = 32.4Dc =
Mx = 24.6Dc =
My = 12.3Dc =
Mz = 12.3Dc =
Allowable Loads on Compressor Nozzles Based on API-617

e 1 : Vent Nozzle 2 : Vent


6 Inch Ø=Dn= 2
152.4 mm Ø=Dn= 50.8

4271 N Fx = 62
729 N Fy = 109
-1688 N Fz = 395
0 N.m Mx = -8
0 N.m My = -4
0 N.m Mz = 0

4649.971 N Fr = √ (Fx)2+(Fy)2+(Fz)2 = 414.427


0 N.m Mr = √ (Mx)2+(My)2+(Mz)2 = 8.944

54.1 Dn Fr + 1.09 Mr ≤ 54.1 Dn

8244.84 424.177 ≤ 2748.28

5321 N
6995 N
-2044 N
-8 N.m
-4 N.m
0 N.m

9023.35869 N
8.94427191 N.m

18232.2216 mm2
2025.8024 mm2
18232.2216 mm2
72928.8864 mm2
111419.132 mm2

376.742883 mm

40.4 Dc
15220.4125

Allowable Actual
6065.56042 5321 N
15258.0868 6995 N
32.4 -2044 N
9267.87493 -8 N
4633.93746 -4 N
4633.93746 0 N
Nozzle 3 : Discharge
Inch Ø=Dn= 6 Inch
mm Ø=Dn= 152.4 mm

N Fx = 949 N
N Fy = 3964 N
N Fz = -766 N
N.m Mx = 0 N.m
N.m My = 0 N.m
N.m Mz = 0 N.m

Fr = √ (Fx)2+(Fy)2+(Fz)2 = 4147.367
Mr = √ (Mx)2+(My)2+(Mz)2 = 0

Fr + 1.09 Mr ≤ 54.1 Dn

4147.367 ≤ 8244.84
Nozzle 4 : Inlet
Ø=Dn= 12 Inch
Ø=Dn= 304.8 mm

Fx = 39 N
Fy = 2193 N
Fz = 15 N
Mx = 0 N.m
My = 0 N.m
Mz = 0 N.m

Fr = √ (Fx)2+(Fy)2+(Fz)2 = 2193.398
Mr = √ (Mx)2+(My)2+(Mz)2 = 0
De=((400+Dn)/3)) = 234.93333 mm
Fr + 1.09 Mr ≤ 54.1 De

2193.398 ≤ 16462.248