2 Version 3.0 EN
Operating manual / Hydraulic breakers
Contents
Contents
1 General Information ...........................................................................5
1.1 For the operating personnel ..........................................................5
1.2 Liability ..........................................................................................6
1.3 For better understanding of this manual .......................................6
2 Safety................................................................................................... 7
2.1 Intended use .................................................................................7
2.2 Qualification of the personnel........................................................ 7
2.3 Prohibition, warning, mandatory and instruction signs on the
device ...................................................................................................8
2.4 Basic safety instructions................................................................ 8
2.5 Duties of the operator.................................................................. 12
2.6 Personal protective equipment.................................................... 12
3 Scope of delivery..............................................................................13
4 Product description .........................................................................14
4.1 Technical specifications ..............................................................14
4.2 Device description .......................................................................14
4.3 Product identification...................................................................15
5 Transport and storage .....................................................................16
5.1 Manual transportation .................................................................17
5.2 Transportation using a lifting tool ................................................17
5.3 Moving the support frame using the mounted hydraulic breaker 18
5.4 Storage........................................................................................ 19
6 Mounting the hydraulic breaker on the support frame.................20
6.1 Unpacking ...................................................................................20
6.2 Mounting conditions ....................................................................20
6.3 Required tool ...............................................................................20
6.4 Necessary accessories ...............................................................20
6.5 Mounting the hydraulic breaker ...................................................21
6.6 Fitting and removing the plug tool ...............................................23
6.7 Connecting the hydraulic breaker hydraulically........................... 25
7 Commissioning ................................................................................28
7.1 First commissioning; Re-commissioning after a standstill........... 28
8 Operation ..........................................................................................30
8.1 Operating range .........................................................................30
8.2 Site selection ...............................................................................30
8.3 Information regarding the mode of operation ..............................31
8.4 Process flow ................................................................................34
8.5 Underwater operation.................................................................. 35
9 Tool....................................................................................................36
10 Maintenance (DIN EN 31051)........................................................... 37
10.1 Cleaning and servicing ..............................................................37
10.2Inspection and maintenance .......................................................38
10.3Repairs ........................................................................................42
10.4Spare and wear parts..................................................................43
Version 3.0 EN 3
Operating manual / Hydraulic breakers
Contents
4 Version 3.0 EN
Operating manual / Hydraulic breakers
General Information
1 General Information
Applicable documents
• Spare parts catalogue including the parts list and drawings
• Technical details regarding the hydraulic breakers
Note
NOTE Detailed information regarding the scope of the provided
documentscan be found in the “packing list”
Version 3.0 EN 5
Operating manual / Hydraulic breakers
General Information
1.2 Liability
Franz is not liable for any material defect and guarantee claim in case of
damage caused due to improper use and unauthorised interferences not
provided for in this mounting instruction.
Details regarding material defect claims can be found in the General
Terms and Conditions provided by Franz.
Unauthorised structural modifications to the hydraulic breaker are not
permitted for safety reasons. In addition, you cannot make any changes
in the installation (connections among other things).
Parts and components have been specially designed for the hydraulic
breaker. We would also like to specifically draw your attention to the fact
that parts and special equipment that has not been delivered by us, has
also not been approved by us. Installing and/or using such products can
affect the safety.
Conventions
Danger!
DANGER
This danger sign indicates an imminent, great danger that, in all
probability, causes severe injuries or even death in some cases if the
dangerous situation is not dealt with properly.
Warning!
WARNING
This danger sign indicates a possible danger that can cause severe
injuries or even death in some cases if the danger situation is not dealt
with properly.
Caution!
CAUTION
This danger sign indicates a potentially dangerous situation that can
cause minor or moderate physical injuries or material damage if such a
situation is not dealt with properly.
Note
NOTE
This sign indicates additional information.
6 Version 3.0 EN
Operating manual / Hydraulic breakers
Safety
2 Safety
The hydraulic breaker has been manufactured in accordance with the
generally accepted norms of technology. Nevertheless, there is danger
to persons or property if you do not observe the following basic safety
instructions and warnings about instructions in this operating manual.
Read this operating manual thoroughly and in its entirety before you
mount the hydraulic breaker and work with it.
Keep the operating manual such that it is always easily accessible to
all users.
Always pass on the hydraulic breaker to a third party together with the
operating manual.
Version 3.0 EN 7
Operating manual / Hydraulic breakers
Safety
Note
NOTE
More prohibition, warning, mandatory and instruction signs of
components may be affixed on the support frame and on attachments
of the support frame. Information regarding the individual prohibition,
warning, mandatory and instruction signs can be found in the relevant
operating manual.
8 Version 3.0 EN
Operating manual / Hydraulic breakers
Safety
• Follow the instructions about using the hydraulic breaker in the support
frame operating manual.
• Use the hydraulic breaker only if it is in a technically sound condition.
• Repair the defects in the hydraulic breaker immediately. Inform Franz
immediately in case of malfunctions. Do not make any modifications or
re-constructions in the hydraulic breaker, otherwise the declaration of
conformity becomes invalid and the operating permit is terminated.
• Check the hydraulic breaker for visible defects such as cracks in the
casing, screws, covering caps or seals.
• You may not fundamentally modify or re-construct the hydraulic
breaker.
• Use the hydraulic breaker within the range of capacity only, which is
specified in the Technical Details.
• Do not use the hydraulic breaker in explosive environments if there is
no explicit permission for it.
• Close the front panel of the support frame before you start working with
the hydraulic breaker.
• Wear the necessary protective equipment, e.g. protective helmet, ear
muffs, protective clothing among other things as per the requirements.
• Do not wear loose clothing or jewellery that could get caught in the
operating elements or other parts of the support frame.
• Persons who are under the influence of alcohol, drugs or medicines
may not transport, mount, commission, operate or repair the hydraulic
breaker.
• Only ask for standard signs and that too from one person only when
working on the site.
• The minimum age limit for the operating personnel is 18 years.
• Fasten all the loose objects such as tools and remove these objects
from catwalks, levels, etc.
• Ensure that all the safety equipment belonging to the hydraulic breaker
is available, installed properly and is fully functional. You may not
change the position of the safety equipment, handle it or make it
ineffective.
• Ensure that the activated user can be brought into a safe position (e.g.
immediate stop) by using a proper EMERGENCY STOP function.
• Follow the warning and instruction signs attached to the hydraulic
breaker. In addition, ensure that these signs are not removed and that
they are always legible.
• Comply with the prescribed purity level as per ISO 4406 (c) of the
hydraulic pressure medium. You can find information regarding the
purity level in the support frame operating manual.
Version 3.0 EN 9
Operating manual / Hydraulic breakers
Safety
10 Version 3.0 EN
Operating manual / Hydraulic breakers
Safety
For transportation
• Follow the transportation instructions on the packaging.
For commissioning
• Ensure that all the hydraulic connections are covered or closed.
Operate a fully installed hydraulic breaker only.
For cleaning
• Close all the openings using suitable protective equipment such that the
cleaning agents do not enter the system.
• Use a suitable cleaning device for cleaning and follow the instructions
regarding the cleaning device.
• Wear protective clothing (e.g. protecting goggles, face mask among
other things) when dealing with compressed air or pressurised water.
For maintenance
• Carry out the prescribed maintenance work at intervals specified in the
operating manual.
• Ensure that no line links, connections and components come off till the
system is under pressure.
• Do not search for leakages with bare hands; the pressure medium can
come out with high pressure which can cause injuries.
Version 3.0 EN 11
Operating manual / Hydraulic breakers
Safety
For disposal
• Dispose of the hydraulic breaker as per the country-specific regulations.
• Dispose of the pressure medium or grease as per the country-specific
regulations.
• Dispose of the pressure medium residues or grease in accordance with
the valid safety data sheets for pressure mediums and grease.
• Consult Franz or your dealer when using biodegradable mediums.
12 Version 3.0 EN
Operating manual / Hydraulic breakers
Scope of delivery
3 Scope of delivery
The following is included in the scope of delivery:
• Hydraulic hammer according to the technical
specification and "order specification"
Note
NOTE
• Check the scope of delivery for completeness.
• Check the scope of delivery for possible transportation damage, also
see chapter “5 Transport and Storage” on page 16.
• Check whether the operating manual is suitable for the hydraulic
breaker.
Version 3.0 EN 13
Operating manual / Hydraulic breakers
Product description
4 Product description
Note
NOTE
Inform your dealer or Franz, if the Technical Details are not provided
during the delivery.
Note
NOTE
A sample design has been shown in the following figure. The delivered
hydraulic breaker can thus deviate from the figure
14 Version 3.0 EN
Operating manual / Hydraulic breakers
Product description
Note
NOTE
The identification plate is attached on the left side on the hydraulic
breaker.
1 2
Franz GmbH
86720 Nördlingen GERMANY
4 TYPE: xxxx
5 SER.NO.: xxxx
6 WEIGHT [kg]: xxxx
7 YEAR: xxxx
2 8 3
Version 3.0 EN 15
Operating manual / Hydraulic breakers
Note
NOTE
Information regarding the weight of your hydraulic breaker can be found
in the Technical Details.
Franz GmbH
Gewerbering 9
86756 Reimlingen
GERMANY
16 Version 3.0 EN
Operating manual / Hydraulic breakers
Ensure that the load bearing capacity of the lifting tool is sufficient for
transporting the hydraulic breaker safely.
Use textile sling gears – in accordance with DIN EN 1492-2.
Note
NOTE
Please contact Franz for more information regarding the transportation.
Version 3.0 EN 17
Operating manual / Hydraulic breakers
18 Version 3.0 EN
Operating manual / Hydraulic breakers
5.4 Storage
The hydraulic breaker can be stored for up to six months in the company
as long as the following criteria are met:
• The hydraulic breaker should be stored in the downward direction
perpendicular to the tool so that the existing seals are not damaged due
to the dead weight of the hydraulic breaker.
• Store in dry and well ventilated rooms only and protect it from soil
humidity.
• Cover with a sheet for protecting from dust and dirt.
• Close all connections using closing plugs.
• After opening the transport package, close it again properly for storage
purposes.
Note
NOTE
Consult Franz for storage exceeding six months.
Version 3.0 EN 19
Operating manual / Hydraulic breakers
6.1 Unpacking
Dispose of the packaging as per the country-specific regulations.
Note
NOTE
Contact your dealer for more information regarding the accessories.
20 Version 3.0 EN
Operating manual / Hydraulic breakers
Note
NOTE
Have a sufficiently big collection container, enough cloth and medium-
binding materials ready to collect or absorb the hydraulic oil coming out.
1. You must ensure that the surroundings are clean before mounting
and removing so that dirt does not enter the oil circuit. Only use non-
linting fabric or speciality paper for cleaning purposes.
2. Bring the jib of the support frame in an optimal position so as to hold
the hydraulic breaker with the quick-changer.
Note
NOTE
Follow the instructions of the quick-changer manufacturer.
Version 3.0 EN 21
Operating manual / Hydraulic breakers
22 Version 3.0 EN
Operating manual / Hydraulic breakers
Version 3.0 EN 23
Operating manual / Hydraulic breakers
Caution!
CAUTION
Pay attention to the weight of the tool! Transport the tool securely
and use a lifting gear if necessary.
5. Insert the retaining bars (3) and again till the locking pins (2) and
the screw (1).
Version 2:
Caution!
CAUTION
Pay attention to the weight of the plug tool! Transport the tool
securely and use a lifting gear if necessary.
5. Storing the tool safely and securing it against shifting.
24 Version 3.0 EN
Operating manual / Hydraulic breakers
Note
NOTE
Follow the instructions of the support frame manufacturer.
Note
NOTE
Pay attention to the parameters of the hydraulic system.
1. Check the parameters of the support frame hydraulic system to
ensure that they correspond to the Technical Details of the hydraulic
breaker. If they do not correspond, the appropriate change must
be made in accordance with the operating manual of the hydraulic
system or the support frame.
2. Connect the relevant part of the hydraulic system to the support frame
at zero pressure.
Version 3.0 EN 25
Operating manual / Hydraulic breakers
3. Connect all the connections and follow the support frame operating
manual.
Note
NOTE
Pay attention to the different designs of the hydraulic connections of the
hydraulic breaker in the following figures.
IN OUT
26 Version 3.0 EN
Operating manual / Hydraulic breakers
Note
NOTE
Mark all the checked fittings, with a permanent marker for instance.
9. Ensure that the pipes and hose lines and every combination of
fittings, couplings or joints with hoses or pipes are checked for their
safe working condition by a technical expert.
Version 3.0 EN 27
Operating manual / Hydraulic breakers
Commissioning
7 Commissioning
Danger of material damage and personal injuries!
DANGER
The commissioning of the hydraulic breaker requires basic mechanical
and hydraulic knowledge as well as knowledge regarding the operation
of the support frame.
The hydraulic breaker may be commissioned only by qualified
personnel (see section “2.2 Qualification of Personnel” on page 7).
28 Version 3.0 EN
Operating manual / Hydraulic breakers
Commissioning
Caution!
CAUTION
Press the working tool against the piston so that the space between the
piston and the working tool does not fill with grease.
Version 3.0 EN 29
Operating manual / Hydraulic breakers
Operation
8 Operation
The hydraulic breaker may be operated in certain areas only; see the
operating manual of the support frame.
The hydraulic breaker must always be within the operator’s field of vision
during operation; therefore, you must always position the support frame
such that the operator always has a free field of vision of the hydraulic
breaker.
30 Version 3.0 EN
Operating manual / Hydraulic breakers
Operation
Version 3.0 EN 31
Operating manual / Hydraulic breakers
Operation
31
Operating manual / Hydraulic breakers
Operation
31
Operating manual / Hydraulic breakers
Operation
Figure15: Vibrations
• Avoid strokes without load since it may damage the hydraulic breaker.
• Do not use the hydraulic breaker as a ripper or break lever.
32 Version 3.0 EN
Operating manual / Hydraulic breakers
Operation
• Do not operate the hydraulic breaker for more than 30 seconds at the
same point without the tool penetrating. It can lead to overheating and
damage the tool tip.
Search for a suitable point where the tool can penetrate, e.g. a weak
spot in the material.
• Do not rotate the support frame such that you take support of the tip.
Version 3.0 EN 33
Operating manual / Hydraulic breakers
Operation
Pre-conditions
• The hydraulic breaker is attached to the quick-changer of the support
frame, see chapter “6 Attaching the hydraulic breaker to the support
frame” on page 20.
• The support frame is standing in the correct position.
34 Version 3.0 EN
Operating manual / Hydraulic breakers
Operation
Work steps
� Start the support frame and execute further work steps for the
operation as per the operating manual.
� Position the tool at the desired position.
� Firmly press on the material to be broken using the hydraulic breaker.
The correct pressure is built if the support frame gives the impression
of becoming lighter.
� Start the hydraulic breaker and follow the instructions in section “8.3
Information regarding the mode of operation” on page 31.
� Maintain the pressure and break the material by penetrating or by
means of pressure waves.
� Change the position of the hydraulic breaker if the material is not
broken within 15 seconds.
� Stop the hydraulic breaker if the material is broken.
� Repeat the preceding work steps till all the material has been broken
and follow the instructions in section “8.3 Information regarding the
mode of operation” on page 31.
� Stop the support frame.
Version 3.0 EN 35
Operating manual / Hydraulic breakers
Tool
9 Tool
Selecting the correct tool best-suited for a particular application is of great
importance not only with respect to an increase in productivity of the
hydraulic breaker but also with respect to the service life of the tool itself.
The hydraulic breakers are available with a range of specially-designed
tools. Here is a description of the most widely used tools for the
most common jobs; customers can feel free to contact our Technical
Department for special cases in order to find suitable solutions for any
possible problems that may crop up or for specific problems.
The preferences of the user, the type of machine and the special working
conditions can also influence this choice.
The following overview serves as general information.
Table 2: Tool
Chisel tool Moil point tool Blunt tool
36 Version 3.0 EN
Operating manual / Hydraulic breakers
Version 3.0 EN 37
Operating manual / Hydraulic breakers
Danger of damage!
DANGER
Incorrect filling quantity and/or unsuitable lubricant (tool paste) causes
damage to the hydraulic breaker!
10.2.3 Log
The inspection and maintenance conducted must be documented
completely, see section “14.2 Proof of maintenance” on page 50.
38 Version 3.0 EN
Operating manual / Hydraulic breakers
10.2.4 body
Information regarding the maintenance and inspection
Note
NOTE
A sample design has been shown in the following figure. The delivered
hydraulic breaker can thus deviate from the figure.
1 Lubricating nipple
Figure 20:Lubrication point
Version 3.0 EN 39
Operating manual / Hydraulic breakers
Note
NOTE
Follow the maintenance and inspection instructions of the support
frame; see the operating manual of the support frame.
Wear maintenance
All movable parts are subject to wear, which depends on the operating
time, load factor and the operating conditions. There are a few
recommendations since the operating conditions are varied.
Note
NOTE You must reduce the maintenance interval in case of major stress on
the hydraulic breaker or due to environmental influences (e.g. lot off
dust formation, high humidity).
40 Version 3.0 EN
Operating manual / Hydraulic breakers
Checking all side bolts and visible Tighten all the screw fittings if
X1)
screw fittings. necessary.
Checking the tool for wear and Sharpen the tool if necessary or
X1)
cracks. replace it with a new tool.
Checking the hydraulic lines and Replace the hydraulic lines and hoses
X1)
hoses for damage. if necessary.
Checking the play between the tool The clearance may not be greater
holder (bush) and the tool than 5% of the tool, otherwise
immediately ask the dealer or an X1)
authorised service to replace the
bush.
Visual checking for leakages. Existing leakages must be repaired by
the dealer or an authorised service, X1)
e.g. replacing seals.
Checking the tool and the tool holder The tool must be rotated by 180° and
(bush) for traces of wear. replaced by a new one in case of X1)
strong traces of wear and ridges.
Replacing the seals and diaphragms In case of tough conditions and strong
of the nitrogen accumulator loads.
X1)
Replacement must be done by the
dealer or an authorised service.
Replacing the seals and diaphragms In case of normal conditions and
of the nitrogen accumulator normal loads.
X1)
Replacement must be done by the
dealer or an authorised service.
Checking the flow of hydraulic oil Checking must be done by a qualified
through the hydraulic breaker. person and the check must be X1)
documented.
Checking the hydraulic lines and Checking must be done by a qualified
hoses. person and the check must be X1)
documented.
1) Including the following periods
Note
NOTE The hydraulic breaker must be checked regularly during operation for
proper functioning. Inform Tecna immediately in case of malfunctions.
Version 3.0 EN 41
Operating manual / Hydraulic breakers
10.3 Repairs
General conditions
For the breaker to operate correctly, the oil nitrogen accumulator must be
charged adequately. The discharged condition of the accumulator is
shown by strong vibrations of the hydraulic breaker’s oil feed hose. It is
recommended that you disassemble the accumulator every 1000 working
hours (six months) and replace the rubber diaphragm even if it appears to
be in a good condition; see maintenance and inspection plan on page 40.
Once the accumulator is discharged, the polyurethane diaphragm must
be replaced under normal conditions, even if the condition appears to be
satisfactory.
Note
NOTE The oil nitrogen accumulator may be replaced by the dealer or an
authorised service only.
42 Version 3.0 EN
Operating manual / Hydraulic breakers
Spare parts can be ordered with the help of the spare part drawing and
parts list, see Annex.
� Specify the following data from the identification plate when placing an
order:
– The serial number
� Specify the following data from the parts list: –
The material number
� In addition, specify the following:
– The quantity of the desired spare parts
� The desired mode of dispatch (e.g. parcel, cargo, freight, courier
service, etc.).
The order must be addressed to your dealer with the specification of the
order number.
Version 3.0 EN 43
Operating manual / Hydraulic breakers
Note
NOTE
Have a sufficiently big collection container, enough cloth and medium-
binding materials ready to collect or absorb the hydraulic oil coming out.
44 Version 3.0 EN
Operating manual / Hydraulic breakers
Version 3.0 EN 45
Operating manual / Hydraulic breakers
Disposal
12 Disposal
Careless disposal of the hydraulic unit and pressure medium can lead to
environmental pollution.
Therefore, you must observe the following points:
• Dispose of the hydraulic breaker and pressure medium as per the
country-specific regulations.
• The hydraulic breaker does not emit any hazardous substances if it
is used as directed. Hence, there are no negative effects on human
beings and the environment under normal circumstances.
• The hydraulic breaker can be reused mainly with respect to the material
because of the high metal content. An optimum metal recycling can be
achieved by dismantling individual assemblies.
46 Version 3.0 EN
Operating manual / Hydraulic breakers
Version 3.0 EN 47
Operating manual / Hydraulic breakers
Note
NOTE
For more information on troubleshooting, contact your dealer or an
authorised service.
See the operating manual of the support frame in case of faults in the
support frame.
48 Version 3.0 EN
Operating manual / Hydraulic breakers
Annex
14 Annex
Note
NOTE
Franz recommends the breaker tool grease
Professional Hammer Grease II. In Table 4 are the specification
of hammer grease.
Order Number: F170228
Table 4
NLGI-class 2
Appearance Fine-grained
Colour gold
Thickener Aluminium complex
Nominal operating range, °C
°C –20 °C bis +1000
Nominal operating range, °C ASTM D-217 270 dmm
Dropping point, °C ASTM D-566 >260 °C
Pour point, °C ASTM D-97 -18 °C
Base oil viscosity grade, ISO ASTM D-445 1000 cSt
4 ball wear test,1200 rpm,75°C,40Kg.1h.,mm ASTM D-2266 0,8 mm
4 ball EP Test, weld load , Kg. ASTM D-2783 >250 Kg
Evaporation, 22 h. @ 150°C, % ASTM-D-972 <1%
Resistance in humidity cabinet ASTM-D-1748 >700
Relative density @ 15°C, Kg./m3 ASTM-D-1480 980 Kg/m3
Version 3.0 EN 49
Operating manual / Hydraulic breakers
Annex
1 4 2 3
18
17 F200
16 F300
15
14
13
12
11
10 F150
9
8
7
6
-20 0 20 40 60 80
(-4) (32) (68) (104) (140) (176)
ambient temperature°C (°F)
19
18
17
16
15
14
13
12
11
10
-20 0 20 40 60 80
(-4) (32) (68) (104) (140) (176)
ambient temperature°C (°F)
50 Version 3.0 EN
Operating manual / Hydraulic breakers
Annex
Version 3.0 EN 51
Franz GmbH
Gewerbering 9
86756 Reimlingen
GERMANY