0% found this document useful (0 votes)
5K views8 pages

L&T Electric Meter Specifications Guide

This document provides information on electricity meters for various consumer segments and applications. It describes single phase energy meters and trivector meters, including their technical specifications, features, and ordering information. The meters can be used for residential, commercial, and industrial applications, and support parameters like maximum demand, time of day tariffs, and bidirectional energy recording for solar applications.

Uploaded by

vikrant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5K views8 pages

L&T Electric Meter Specifications Guide

This document provides information on electricity meters for various consumer segments and applications. It describes single phase energy meters and trivector meters, including their technical specifications, features, and ordering information. The meters can be used for residential, commercial, and industrial applications, and support parameters like maximum demand, time of day tariffs, and bidirectional energy recording for solar applications.

Uploaded by

vikrant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Product Overview
  • Single Phase Energy Meter
  • Ordering Information and Technical Specifications
  • Offices and Contact Information

The Right Measure

Meters for all consumer segments and applications

Inter Utility & Open


Solar Roof Top
Access Consumer Billing

ABT Meters

DT/Feeder Meter Residential

Application

Industrial Commercial

CT/PT Operated Single & Three Phase Direct


Trivector Meters Connected Meters;
Bi-Directional/NET Meters for
Solar, Windmill application

Electricity Meters/Sources of Revenue


Single Phase Energy Meter

Salient Features
• Class 1 accuracy as per IS13779
• Fully static & compact in size with bright LCD display
• Current rating 5-30A & 10-60A
• Display consists of auto scrolling, manual scrolling (6+0 digit), battery
mode & high resolution mode (2+4 digits)
• Wide range of communication options - Optical/ RS 232/RF
(optional)/DLMS (Optional)
• Anti-tamper features
• Forward energy recording irrespective of current direction
• High surge withstand capability
• Load surveys are available for 90 days with voltage, current, PF, KW & KVA
• Non time based reset backup or billing profile for last 12 months
• Display and data reading in power OFF condition (with in-built battery
model only)
• Bi-directional energy recording available (Optional-applicable for solar
application)
• Meters are available with suitable hinge type polycarbonate
EM101+ enclosers/boxes (optional)
• Provisions for meter terminal sealing arrangement to prevent tampers
• To download NVM data base computer software & optical to USB cables
are also available (on request & chargeable basis)

Technical Specifications

ELECTRICAL PARAMETERS SUPPORTED (As per customer requirements)


Connection 1 Phase 2 Wire Whole Current type Maximum Demand (MD) kW and kVA along with date and
Accuracy Class 1 as per IS13779 demand integration period is 30 min.
Rated voltage 240 V Instantaneous parameters Voltage, phase and neutral current,
active and apparent powers, power
Voltage variation +20% to -50%
factor, frequency
Current rating 5-30 A, 10-60 A
Time of day tariff TOD 1 for 00-24Hr
Starting current 0.2% of basic current
Cumulative parameters kWh, kVAh energies
Frequency 50Hz ±5%
Power consumption As per IS13779
OTHER FEATURES

STANDARD COMPLIANCE Tamper proofing provision 1. Top cover open


Applicable standards IS13779 2. Single wire operation or neutral
missing
3. Earth load tamper
ENVIRONMENTAL CONDITIONS
Operating temperature -10°C to +55°C 4. Current reversal.

Ingress Protection (IP) IP51 5. Magnetic logging.


Communication Optical IEC1107/ DLMS (optional)
DISPLAY
LCD (6+0) digits backlit display & (2+4)
digits high resolutions display.
LED indicators Pulse LED for kWh
Mechanical Dimensions

1. LCD Display 5. Sealing Screw


2. LED 6. Terminal Cover
3. Optical Port 7. Meter Base
4. Push Button 8. Meter Cover

Note: Actual meter dimensions will depend on meter configuration

Ordering Informations for Single phase Meter

Optical Polycarbonate Rated Current Display Last 6 Month KWH


Internal MD in KW Load
CAT No port/ RTC Box-Hinge Voltage Rating Digits Cumulative Value in Display & Last
Battery KWH & KVA Survey 12 Months in NVM
IEC1107 type (V) (A) (Nos)
WM101BC5DDH Yes Yes Yes No 240 5-30 6+0 Yes Yes Yes Yes
WM101BC5DDHBOX Yes Yes Yes Yes 240 5-30 6+0 Yes Yes Yes Yes
WM101BC7DDH Yes Yes Yes No 240 10-60 6+0 Yes Yes Yes Yes
WM101BC7DDHBOX Yes Yes Yes Yes 240 10-60 6+0 Yes Yes Yes Yes
WM101BC5DL0 NO NO Yes No 240 5-30 6+0 Yes NO NO NO
WM101BC5DL0BOX NO NO Yes Yes 240 5-30 6+0 Yes NO NO NO
WM101BC7DL0 NO NO Yes No 240 10-60 6+0 Yes NO NO NO
WM101BC7DL0BOX NO NO Yes Yes 240 10-60 6+0 Yes NO NO NO

Trivector Meter

Salient Features
• Accuracy class 0.2s, 0.5s, 1.0 as per relevant IS standards
• Suitable for Bi-directional solar/NET metering application (Optional)
• RS485 modbus available in 10-60A Whole Current meters
• Configurable multiple tariffs and maximum demand registers
• Communication via optical / RS 232 / RS 485 / RF / IR / IrDA (optional)
• Anti-tamper features
• Full four quadrant operation
• Display and data reading in power OFF condition
• Factory programmable for unidirectional or Bi-directional
• Suitable hinge type polycarbonate boxes are available (optional)

ER300 P
Technical Specifications

ELECTRICAL PARAMETERS SUPPORTED (As per customer requirements)


Connection Meter is 3P 4W suitable for 3P 4W Maximum Demand (MD) kW and kVA along with date and time
Wire and 3P 3W system
Instantaneous parameters Phase wise voltages and currents,
Accuracy Class 0.2s/0.5s as per 1S14697
active reactive and apparent powers,
Class 1.0 as per 1S13779
power factor, frequency
• Whole current / 240 V (P-N)
Time of Day Tariff Up to 8 Registers, profiles and seasons
Direct Connected
Energy measurement 4 quadrant measurement of kWh,
• CT Operated kVArh, and kVAh
3 Phase 4 Wire 240 V (P-N)
Display
• CT\PT Operated
LCD 8 digit backlit display
3 Phase 4 Wire 63.5 V (P-N)
Display Mode Auto scroll, push button and high
3 Phase 3 Wire 110 V (P-P)
resolution modes
Voltage variation
LED Pulse LEDs for kWh and kVArh
• Whole current / -40% to +20%
OTHER FEATURES
Direct Connected
Load survey kVAh, kWh, kVArh lag, kVArh lead,
CT Operated -30% to +20%
voltages and currents
CT\PT Operated
Data Security Multi level password for data reading
Current Rating and programming
• Whole current / 10-60 A, 20-100 A
Communication Electrically isolated optical port as per
Direct Connected 1S15959/ IEC62056-21 (DLMS)
• CT\VT Operated Optional communication RS 232 / RS 485 / IR / IrDA/
Basic 1A, 5A interfaces RF (2.4 Gliz/865-867 MHz)
Maximum 120 % of basic current (200 % basic Protocol supported DLMS as per IS15959 (optional)
current- Optional)
Tamper Detection (as per Missing Potential, Voltage related
Frequency 50Hz ±5% tampers, Current related tampers,
Power Consumption As per 1S14697 for CT/PT operated Low Power Factor, Meter Cover Open,
As per 1S13779 for whole current Abnormal Magnetic influence, Wrong
STANDARD COMPLIANCE phase sequence detection
Applicable standards IS13779 for class 1 Tamper proofing provision Ultrasonic welding available (optional)
IS14697 for Class 0.2s/0.5s
IEC62053-21, IEC62053-22
ENVIRONMENTAL CONDITIONS
Operating temperature -10°C to +55°C
Ingress Protection (IP) P51

Mechanical Dimensions

1. LCD Display
2. LED kVArh
3. LED kWh
4. Battery Push Button
5. Reset Push Button
6. Up/Down Scroll Push Button
7. Optical Port
8. Meter Base
9. Meter Cover
10. Terminal Cover

Note: Actual meter dimensions will depend on meter configuration


Ordering information for Trivector Meters, WC & LTCT Meters, Accuracy -1.0 for WC & 0.5s for LTCT

Additional Rated Current Display Load Survey CT Ratio need to


Accuracy Internal MD in KW
CAT No RTC Port-RS485 Voltage (V) Rating Digits Cumulative 40 days for all be provided at the
Class Battery KWH & KVA
Modbus (P-P/P-N) (A) (Nos) energy values time of ordering
WR300BC7300 1 Yes Yes No 415/240 10-60A 6+2 Yes Yes Yes NO
WR300BC73RS485 1 Yes Yes Yes 415/240 10-60A 6+2 Yes Yes Yes NO
WR300BC5200 0.5s Yes Yes No 415/240 /5 6+2 Yes Yes Yes Yes
WR300BC1200 0.5s Yes Yes No 415/240 /1 6+2 Yes Yes Yes Yes
WR300BC52RS 0.5s Yes Yes Yes 415/240 /5 6+2 Yes Yes Yes Yes
WR300BC12RS 0.5s Yes Yes Yes 415/240 /1 6+2 Yes Yes Yes Yes

Ordering information for Trivector Meters-HT CT/PT Operated 0.5s or 0.2s

Additional Rated Current Display Load Survey CT Ratio need to


Accuracy Internal MD in KW
CAT No RTC Port-RS485 Voltage (V) Rating Digits Cumulative 40 days for all be provided at the
Class Battery KWH & KVA
Modbus (P-P/P-N) (A) (Nos) energy values time of ordering
WR300BB5200 0.5s Yes Yes No 110/63.5 /5 6+2 Yes Yes Yes Yes
WR300BB52RS 0.5s Yes Yes Yes 110/63.5 /5 6+2 Yes Yes Yes Yes
WR300BB1200 0.5s Yes Yes No 110/63.5 /1 6+2 Yes Yes Yes Yes
WR300BB12RS 0.5s Yes Yes Yes 110/63.5 /1 6+2 Yes Yes Yes Yes
WR300BB5100 0.2s Yes Yes No 110/63.5 /5 6+2 Yes Yes Yes Yes
WR300BB51RS 0.2s Yes Yes Yes 110/63.5 /5 6+2 Yes Yes Yes Yes
WR300BB1100 0.2s Yes Yes No 110/63.5 /1 6+2 Yes Yes Yes Yes
WR300BB11RS 0.2s Yes Yes Yes 110/63.5 /1 6+2 Yes Yes Yes Yes

ABT (Availability Based Tariff) Meter

Salient Features
• Accuracy class 0.2s as per relevant IS 14697
• Frequency based energy measurement
• Suitable for inter-utility or open access consumer billing
• Store energy values in every 15 mints block along with avg frequency in
same interval
• ABT meters are also available as per PGCIL specs, guidelines & capable of
convert data in NPC format (Power Grid's report format)
• Consider Step frequency 0.01Hz.
• Communication via optical (IEC1107/DLMS) / RS232 / RS485
(MODBUS/DLMS)-(Optional)
• Anti-tamper features
• Display and data reading in power OFF condition
• Capable of recording Load Survey data & easy download through Base
Computer Software
• Approved in all major utilities across the country

ER300 P
Technical Specifications

ELECTRICAL PARAMETERS SUPPORTED (As per customer requirements)


Connection 3 Phase 4 Wire Maximum Demand (MD) kW and kVA along with date and time
(Optional)
Accuracy Class 0.2s/0.5s (active/reactive) as per
Instantaneous parameters Phase wise voltages and currents,
IS14697 or 0.2s/0.2s (active/active).
active reactive and apparent powers,
• CT\PT Operated power factor, frequency
3 Phase 4 Wire 63.5 V (P-N) Time of Day Tariff Up to 8 Registers, profiles and seasons
(Optional)
3 Phase 3 Wire 110 V (P-P)
Energy measurement Frequency based.
Voltage variation
Display
• Whole current / -40% to +20% LCD 8 digit backlit display
Direct Connected Display Mode Auto scroll, push button and high
• CT Operated -30% to +20% resolution modes
CT/PT operated LED Pulse LEDs for kWh and kVArh
OTHER FEATURES
Current Rating
Load survey kVAh, kWh, kVArh lag, kVArh lead,
• CT\VT Operated phase wise voltages and currents
Basic 1A, 5A Data Security Multi level password for data reading
Maximum 120 % of basic current (200 % basic and programming
current-Optional) Communication Electrically isolated optical port as per
1S15959/ IEC62056-21 (DLMS, CAT B)
Frequency 50Hz ±5%
Optional communication RS 232 / RS 485.
Power Consumption As per 1S14697 for CT/PT operated interfaces
STANDARD COMPLIANCE Protocol supported DLMS as per IS15959 and MODBUS
Applicable standards IS14697 for Class 0.2s/0.5s (For RS485)
IEC62053-21, IEC62053-22 Tamper Detection (as per Missing Potential, Voltage related
customer requirements) tampers, Current related tampers, Low
ENVIRONMENTAL CONDITIONS Power Factor, Meter Cover Open,
Operating temperature -10°C to +55°C Abnormal Magnetic influence, Wrong
phase sequence detection
Ingress Protection (IP) P51
Tamper proofing provision Ultrasonic welding available.

Mechanical Dimensions

1. LCD Display
2. LED kVArh
3. LED kWh
4. Battery Push Button
5. Reset Push Button
6. Up/Down Scroll Push Button
7. Optical Port
8. Meter Base
9. Meter Cover
10. Terminal Cover

Note: Actual meter dimensions will depend on meter configuration

For CAT Nos. details of ABT meters contact with nearest branch offices.
Electrical Standard Products (ESP) Offices:

HEAD OFFICE Khairasol, Degaul Avenue L&T Business Park,


L&T Business Park, Durgapur 713 212 Tower 'B' / 5th Floor
Tower 'B' / 3rd Floor Tel: 0343-2540448 / 2540449 / 2540443 Saki Vihar Road, Powai
Saki Vihar Road, Powai Fax: 0343-2540442 Mumbai 400 072
Mumbai 400 072 e-mail: [email protected] Tel: 022-67052874 / 2737 / 1156
Tel: 022-67053229 Fax: 022-67051112
Fax: 022-67051112 5, Milanpur Road, Bamuni Maidan e-mail: [email protected]
e-mail: [email protected] Guwahati 781 021
Tel: +91 8876554410 / 8876554417 12, Shivaji Nagar
BRANCH OFFICES Fax: 361-2551308 North Ambajhari Road
501, Sakar Complex I e-mail: [email protected] Nagpur 440 010
Opp. Gandhigram Rly. Station Tel: 0712-2260012 / 6606421
Ashram Road II Floor, Vasantha Chambers Fax: 2260030 / 6606434
Ahmedabad 380 009
5-10-173, Fateh Maidan Road e-mail: [email protected]
Tel: 079-66304006-11
Hyderabad 500 004
Fax: 079-66304025
e-mail: [email protected] Tel: 040-67015052 32, Shivaji Marg
Fax: 040-23296468 P. O. Box 6223
38, Cubbon Road, P. O. Box 5098 e-mail: [email protected] New Delhi 110 015
Bengaluru 560 001 Tel: 011-41419514 / 5 / 6
Tel: 080-25020100 / 25020324 Monarch Building, 1st Floor Fax: 011-41419600
Fax: 080-25580525 D-236 & 237, Amrapali Marg e-mail: [email protected]
e-mail: [email protected] Vaishali Nagar
Jaipur 302 021 L&T House
131/1, Zone II Tel: 0141-4385914 to 18 P. O. Box 119
Maharana Pratap Nagar Fax: 0141-4385925 191/1, Dhole Patil Road
Bhopal 462 011 e-mail: [email protected] Pune 411 001
Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Tel: 020-66033395 / 66033279
Fax: 0755-3080502 Akashdeep Plaza, 2nd Floor Fax: 020-26164048 / 26164910
e-mail: [email protected] P. O. Golmuri e-mail: [email protected]
Jamshedpur 831 003
Plot No. 559, Annapurna Complex Jharkhand Crystal Tower,
Lewis Road Tel: 0657-2312205 / 38 4th Floor, G. E. Road
Bhubaneswar 751 014 Fax: 0657-2341250 Telibandha
Tel: 0674-6451342 / 2436690 / 2436696 e-mail: [email protected] Raipur - 492 006
Fax: 0674-2537309 Tel: 0771-4283214
e-mail: [email protected] Skybright Bldg; M. G. Road e-mail: [email protected]
Ravipuram Junction, Ernakulam
Aspire Towers, 4th Floor Kochi 682 016 3rd Floor
Plot No. 55, Phase-I Tel: 0484-4409420 / 4 / 5 / 7 Vishwakarma Chambers
Industrial & Business Park Fax: 0484-4409426 Majura Gate, Ring Road
Chandigarh-160 002
e-mail: [email protected] Surat 395 002
Tel: 0172-4646840 / 41 / 42 / 46 / 53
Fax: 0172-4646802 Tel: 0261-2473726
Email: [email protected] 3-B, Shakespeare Sarani Fax: 0261-2477078
Kolkata 700 071 e-mail: [email protected]
L&T Construction Campus Tel: 033-42005982
TC-1 Building, II Floor Fax: 033-22821025 / 7587 Radhadaya Complex
Mount-Poonamallee Road e-mail: [email protected] Old Padra Road
Manapakkam Near Charotar Society
Chennai 600 089 A28, Indira Nagar, Faizabad Road Vadodara 390 007
Tel: 044-2270 6800 Lucknow 226 016 Tel: 0265-6613610 / 1 / 2
Fax: 044-22706940 Tel: 0522-4929905 / 04 Fax: 0265-2336184
e-mail: [email protected] Fax: 0522-2311671 e-mail: [email protected]
e-mail: [email protected]
67, Appuswamy Road Door No. 49-38-14/3/2, 1st floor,
Post Bag 7156 No: 73, Karpaga Nagar, 8th Street NGGO's Colony, Akkayyapalem,
Opp. Nirmala College K. Pudur Visakhapatnam - 530 016
Coimbatore 641 045 Madurai 625 007 Tel: 0891-2791126 / 2711125
Tel: 0422-2588120 / 1 / 5 Tel: 0452-2567405 / 2561068 / 2561657 Fax: 0891-2791100
Fax: 0422-2588148 Fax: 0452-2567552 Email: [email protected]
e-mail: [email protected] e-mail: [email protected]

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Larsen & Toubro Limited, Electrical Standard Products


Powai Campus, Mumbai 400 072

Customer Interaction Center (CIC)


BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858
SP 50855

Tel : 022 6774 5858, Fax : 022 6774 5859


E-mail : [email protected] / Website www.Lntebg.com

Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai 400 001, INDIA CIN: L99999MH1946PLC004768