ZWO ASI Cooled Cameras
Quick Guide
Thank you very much for purchasing the ZWO ASI camera. This instruction is a brief
summary of the installation procedure to get you up and running with your new
camera. Please be sure to read it before use.
Please head over to the ZWO website if you want more detailed information on the
camera.How to connect to the computer ? (For Windows users)
1. Go to the ZWO official website ([Link]
click [Support] - [Software].
S000 oo
=)
Sofware aa Drives
2. Go to [Native Drivers] - [ASI Cameras] then download the driver (Only
Windows system require this step). Then go [Software] and download
[ASIStudio]. Be aware of the different versions for x64 and x32 systems.
ana eco Windows Mac nox Mobile op Developers FW Unde
coma | ®D
— L—@3. Double click the files to install the ASI camera driver and ASIStudio.
4, Open ASIStudio, start with ASIImg.
rs)
5. Plug the 12v power supply cable into the DC connector on the camera
(Connector type 5.5*2.1mm, center positive, 12V 3A required), then connect
the camera to computer via the USB 3.0 cable that is included in the box. Click
Play icon to start imaging. Please notice that the camera needs to be powered
by 12v power supply, just connecting it to computer with a USB cable will lead
to a recognition failure issue.
zwoasisz0ommPro «| Q|@ @6. Adjust the settings for the camera.
. :
CPU Temperature and Cooling Status a ew
Camera Settings —|
Auto-run Setting —|
Saving Path —|
Histogram Adjustment —|
Process and Status of Auto-run Camera Exposure Status
7. AHelp function is available from within the application by clicking the
help button This document will provide a more detailed guide should you
require it. Hovering over an icon will also pop up a brief explanation of that
function.
° g
eee pa Help
ton Document
noKnuca SO ® O
Corresponding
ASIImg Manual 1. Introduction Software Usage
shy imaging software specially developed for 2W0 cameras, it offers avery broad variety of Manual
somos sta deo hy og
Costes nang mage preven, eon hice tech ana chore
2. User Interface
Introduction >
[Link] Interface > —
[Link] Guide >
seartautown8. For 3rd party software ASCOM drivers should be installed before use.
8.1 Download the main ASCOM platform and the ZWO camera ASCOM driver.
8.2 ZWO ASCOM drivers allows the use of your camera for imaging in 3rd party
software such as MaximDL, N.I.N.A, Sequencer Generator Pro and for guiding
using PHD2.
sao SS imaas one —- D)
eee ee
8.3. ASCOM configuration
There are two camera options in the ASCOM configuration window “ASCOM
Camera Chooser” , if you plan to use two cameras simultaneously for both
imaging and guiding, then please choose “ASI Camera (1)” asthe main
camera and choose “AS| Camera (2)” as the guide camera.
Trace Alpaca
Select the type of canera you heve, then be sure to
click the Properties... button to configure the
driver for your canere
[ST Canara) +] _Eroperties
irae age
cmcaditian of? cxenID SaIfyou only plan to use one camera, then just choose “ASI Camera (1)”.
Click [Properties] to configure the camera.
Three common settings for DSO imaging are available.
Low Gain]: Suitable for targets with high dynamic range, such as M42. It
provides maximum dynamic range.
[Mid Gain]: Can be used in most cases. If you are not sure which kind of gain to
set, then it is recommended to choose this.
High Gain]: Suitable for lucky imaging or other imaging methods with short
exposure time. It provides lowest readout noise, also low dynamic range.
Or you can also choose [manual] mode to configure these settings to your own
liking.
Cemected Cmeras via IEE T: O46 °C
(ive sstoeime reettno) =] Rate
nege Togs [BAIS =] Antictey fon =]
Beyer Fottera: 8655 Honan
west SEGRE =] «att | Atrmwes | —Pre-setting
i
Tovert Faae nese
Gain 8
orto, —————} — 65
fers] pr
Tip: Plawce ean dovn “USB Cini?
Hibze inage var ebtained % | Connel
Choose the camera setup as you need, click [OK] to complete the configuration.How to connect your cooled camera to telescope?
Please refer to the telescope manual to understand what extension tubes or
adapters maybe required to connect your ZWO camera. The use of an
accessory such as a field flattener or reducer may require a specific back focus
distance.
f
M43 lens (] ~—— i —___ 7
3 @
EOS lens { |
@ ® © @
- —j—|- |
LY
Telescope - 7 7 _| 4/3" 1" Cooled camera
® ® ® 9] (exclude 11mm ring)
- [|- |-
® r4
{|
EOSlens | <——_ —___
Many of these accessories use a common back focus
distance of 55mm. You can visit the ZWO website and find
instructions on how to configure your camera for this:
[Link]
als/[Link]
(Scan the QR Code for the tutorial.)@. M43-T2 adapter (optional)
). EOS-T2 adapter (optional)
@. 2" filter (optional)
). 1.25" T-mount
1.25" filter (optional)
@.M42-1.25" adapter
11mm T2 extender
@. M42-M48 16.5mm extender
©. 72-72 adapter
| ®
LY
[
®
OD
® @
<< —
® ® @ | APS-C/Fullframecooled
camera
<_— |<
4/3" 1" Cooled camera
(include 11mm ring)
APS-C/Full frame cooled
camera
(removed tilt plate)
1.25"/2"/36mm/31mm EFW
EOS-EFW adapter
2). 21mm T2 extender
OAG-L
Sensor tilt plate
5. M48-M42 adapter (optional)
M42 filter drawer
D. 2" EFWCamera ports
USB 2.0 OUT
USB 3.0 IN
+ LED indicator
™ + DC12V
Cooling fan
orn nae)
UsB2.0 cable USB 3.0/USB 2.0 cable DC 12V power supply cable
Connects to guide camera, Connects to 12v power adapter
EFWandotheraccessories USB3.0/USB2.0 (Not included in the box)
ports on computer
FAQs
1. Is it normal to have uneven areas in my images?
Yes, there are many factors may lead to uneven images, such as poorly
configured reducer/flatteners, incorrectly mounted filters, focuser tilt, dust on
the sensor surface etc. Defects in the form of hot/cold pixels, vignetting or
background gradient or other phenomenon, can be removed by the use of
calibration frames in processing.2. Will the camera work without an external power supply?
The power consumption of cooled cameras is significant and cannot be met
with USB power alone, so you will need to use a 12V power supply to power your
cooled camera. Later model cameras produced after the year of 2022 will
encounter recognition failure issue if no power applied.
3. Why does the cooler not work?
3.1 Check if the power supply is working.
Make sure the camera is using DC 12v power, and the red LED power indicator is
‘on. You can use the official ZWO AC-DC 12V power adapter, or 12V portable
power source. The interface standard: 5.5*2.1mm; center positive.
3.2 Check if the cooling function is turned on in your imaging software.
The cooling fan will only spin when the cooling function is turned on in the
software.
USB 3.0
LED indicat
DC 12v4. Why can’ tI find the camera in PHD2 even drivers have already been
installed?
Please check the Device Manager -> Image Device to see whether it has the
ZWO camera in the list. A question mark or exclamation mark normally
indicates the driver is not installed properly. Please uninstall it and close
your antivirus software or firewall. Re-install the driver, then restart your
computer.
2 computer Managernent
File _Aatlon View Help
+o 2m G bm 2 Exe
1 compurer Monagenent toca] ~ Ay ZHUSHOHRO-F
© System Too @ Audio inputs and outputs
Tack Scheduler computer
vent Viewer sm Diskeives
(Bl Shared Folders By Display adaptors
| Local Users and Groups Bi Ferme
@® Peformance i Human ietertoce Devices
Device Manager $B IDE ATATAP controle
» & Storage Fe Imaging devise
Disk Management kKeybourds
{Be Services and Apptications > JE Other devices
Bi asueomc
Network adapters
@ Pons (com avPn,Scan to watch
operating video
Facebook Page
ZWO WEB
SMBEEXEBSPRAB) SuZhou ZWOCo,. Ltd.
Tel: +86 051265923102
TW: [Link]
INS: [Link]
FB: _[Link]
AstronomyCameras
Web: [Link]