.33 hp (.
25 kW) M Series Pump Models
Nominal Displacement
Model Ratio Maximum Working Pressure per Cycle
M, -5 625 psi (43 bar) .83 cu in (13.6 ml)
MDSTV
M, MS(3) -7 900 psi (62 bar) .6 cu in (9.8 ml)
-12 1500 psi (103 bar) .36 cu in (5.9 ml)
M, MS(3), -21 2600 psi (179 bar) .2 cu in (3.3 ml)
29723(3)** -36 4500 psi (310 bar) .12 cu in (2.0 ml)
-71 8800 psi (607 bar) .06 cu in (1.0 ml)
-110 13500 psi (931 bar) .039 cu in (0.6 ml)
-188 15000 psi (1034 bar) .023 cu in (.4 ml)
Key Features MS -220 25000 psi (1723 bar) .021 cu in (.34 ml)
• Choice of 5 models, 9 ratios, • Pressures to 25000 psi
** Not available in 188 ratio
27 possible combinations (1724 bar) (3) Maximum intermittent pressure for stainless steel in the MS and 29723 is 10000 psig (690 bar.)
• Flows to 2 gpm (7.5 l/min) • All Hydraulic fluids, water
• Choice of wetted materials (plain or DI), solvents, mild
chemicals, liquefied gases For service codes, see page 17.
• Single air head For weights and dimensions, see page 18.
• Drive pressure 25 to
125 psi (1.8 to 9 bar)
Optional Modifications
Number Description Number Description
-HP Hand pump attachment (with handle). Provides manual operation of pump for 51809 Normally open air operated release with relief valve. Provides highest release flow
precision pressure control or use without air power. capacity. Will hold full pump psi piloted from drive air. Vents are not threaded. Ref.
26082 Handle only. drawing 56643 for tank top mounting parts.
26220-2 With handle.
Without handle. 51809-1 Normally closed air operated release with relief valve. Used to hold hydraulic jacks.
26220-3 Will release up to 11000 psi (using 100 psi air). Vents are not threaded. Ref. drawing
Kits for converting existing units.
56643 for tank top mounting parts. Not available in 188:1 ratio.
-V Manual release with relief valve. For M and MS pumps only. Provides high pressure
51810 Safety relief valve. Relief is upstream of outlet check. Vent hole 1/16 NPT M or MS
needle valve with internal adjustable safety relief downstream of pump outlet
series -21 through 188.
checks. Tank return is 1⁄8” NPT in pump body.
51811 External air pilot. Provides 1⁄8” NPT port for external air to pilot for remote start/stop.
26063-3 Dead Man valve. ¼” NPT port.
52340 Solid air cap.
26064-3 Combination air regulator/filter with gauge. ¼” NPT port.
52950 Electric stroke counter provision. Micro switch (BZE6-2RQ) mounted on upper cap
26065-3 Speed control valve. ¼” NPT port. trips with each cycle.
26065-3 -C air controls installed on pump. ¼” NPT port.
plus 53175 Level II cleaning.
26064-3 53304 High pressure outlet port. Fits ¼” O.D. high pressure threaded and coned tube.
28320 Manifold mount inlet port. Provides O-ring boss in aluminum block to enable mounting
on side of tank below oil level. Modification applies to M-21 through M-188 only. 53784 Piped exhaust (drive only). For field conversion of any .33 HP pump. Provides ¼” NPT
exhaust port.
28590 Palm or foot start/stop button drive. Spring loaded shut.
53935 Low temperature drive. Enables operation down to 5°F. Some sacrifice of seal life at
28700-1 Air OP release valve. normal temperature. M or MS series.
28926 Remote start/stop control. Provides 1⁄8” NPT bleed signal port for single line 54179 Stroke adjuster (includes 29697 above). Useful for metering applications. Knurled
remote control. knob with vertical scale on pump cap.
29002 Viton air drive. 57905 No return spring. Provides improved fill on suction stroke pumping liquefied gases
by utilizing the inlet pressure. Only available on M and MS series.
29697 Single stroke from remote air pulse. Useful for metering applications. One stroke per
air pulse signal; eliminates automatic cycling. 1⁄8” NPT signal port. 59888 Cycle timer installed.
51331 EPR seals for liquid section for 29723-XX ratio pumps. 80103 Noise reduction kit fitted.
51788 Piped exhaust – standard. Provides connection ports for drive and pilot exhausts. 80348 SAE outlet for M-pumps, 3⁄8” SAE, 6500 psi (448 bar) max.
Enables under tank top mounting and/or natural gas drive.
81499 EPR Seals for M and MS series for Liquid Section.
51794 Piped exhaust – sour gas. With hand pump (HP).
82367 SS trim for 1⁄3 hp drive
51794-2 Piped exhaust – sour gas. Without hand pump (HP).
82500 ATEX Modification (Available on MS & 29723 but not M series).
51804 Muffler (for use with piped exhaust modifications below). ¼” NPT male port.
85630 Conversion kit, new style exhaust muffler.
86337 Extended life air drive.
8 www.haskel.com
Liquids Compatible with Services
Haskel Pumps hp Model 1 2 3 4 5 5A 6
To assist in easier pump selection, we have classified various
M •
popular liquids in groups and assigned to each group a service
MS • •
code. These service code numbers are featured in the chart to MDTV • • •
.33
the right and are designated for each pump series. Seals and MDSTV • • • • •
other wetted materials can be supplied to suit your preferred MCPV • • • • •
liquid. For advice, please contact our technical services 29723 • • • • •
personnel at 818-843-4000.
4B -14 to -37 •
.75
4B -55 to -150 • •
Services
Service Codes AW •
1 Petroleum-based oils, kerosene, water with 5% soluble oil.
ASF • •
DF • • •
2 Plain water, diesel fuel. DSF • • • • •
3 Most phosphate ester-based fire-resistant hydraulic fluids, HF •
e.g. Pydraul, Lindol, Cellulube, Fyrquel, and Houghtosafe HSF • •
1120 and petroleum-based solvents compatible with DHF • •
UHMWPE (Ultra-high Molecular Weight Polyethylene) DSHF • • • •
dynamic seals and Viton static seals.
1.5
DSTV • • • • •
4 Petroleum-based solvents, e.g. boron fuels, aromatic 2 ATV • •
hydrocarbons (benzene, toluene, xylene, hylene, etc.); 2.2
DTV • • •
chlorinated solvents (trichlorethylene, carbon tetrachloride, DSTV -1.5 • • • • • •
chlorobenzine, etc.); mercaptans, Dowtherm A, fluoronated AFD •
solvents (fluorobenzene, fluorochlorethylene, etc.); DFD • • •
Dowtherm E, plus all of Group 3 and some mildly corrosive
ASFD • •
acids compatible with wetted materials. See note 5A
for service with methyl-ethyl-ketone, methyl acetone,
DSFD • • • • •
diacetone, alcohol and freon 22.
DXHF • •
DSXHF • • • •
5 Skydrol and Aerosafe hydraulic fluid; acetone and some
DSXHW • •
alcohols (ethyl, methyl, and isopropyl).
5A. Also suitable for these fluids if Viton static seals are 3 ASFD • •
replaced with EPR; specify modification number 51331 (no
extra charge); e.g., 51331-MDTV-5. Most phosphate ester- GW •
based fluids solidify at approximately 30000 psi. GSF • •
6 Deionized water; demineralized water. DGF • • •
Note: Dynamic seal life with non-lubricating fluids will DGSF • • • • •
understandably be less than with lubricating types. DGSTV • • • • •
6
GWD •
Operating Temperatures GSFD • •
DGFD • • •
Drive Section DGSFD • • • • • •
-4° (25°F) to +65°C (150°F) (low temperature seals are available DGSTVD • • • • •
for Arctic operation).
Liquid Section 8FD •
8SFD • • • • •
For reasonable seal life, high temperature should be limited
to 54° C (130° F), for F and W seal models, 135° C (275° F) for T
8DFD •
8
and TV models (with distance piece).
8DSFD • •
8DSTVD • • •
8HSFD • • • • •
D14STD -125 • • • • •
D14STD -315 • • • • •
10
D14SFD -125 • • • • •
D14SFD -315 • • • • •
www.haskel.com 17
NB. Plan view of
M-Pump is common to
all M-Series pumps.
Net weight 2.65 kg
Boxed weight 2.9 kg
Box size 23 x 18 x 12 cm
Weights and
Dimensions
.33 hp (.25 kW) M Series Pump Models M-7, M-12 MS-7, MS-12
approx. weight 9 lbs (4 kg) approx. weight 9 lbs (4 kg)
Net weight 4 kg
Boxed weight 4.25 kg
Box size 23 x 18 x 12 cm
Net weight 6 kg
Boxed weight 6.5 kg
Box size 30 x 20 x 15 cm
Net weight 2.5 kg
Boxed weight 2.75 kg
Box size 23 x 18 x 12 cm
MS-21, MS-36, MS-71, M-21, M-36, M-71, M-110, M-5 approx. weight 9 lbs (4 kg)
MS-110, MS-188, MS-220 M-188 approx. weight 6 lbs
approx. weight 6 lbs (2.7 kg) (2.7 kg)
18 www.haskel.com
29723-21, 29723-36, 29723-71, 29723-110 MDSTV-5
approx. weight 6.5 lbs (3 kg) Approx weight 15 1/2 lbs (7 kg)
.75 hp (.56 kW) Pump Models
Model 4B-14, 4B-21, 4B-25,
4B-30 and 4B-37
Model 4B-55 through
4B-150
www.haskel.com 19