The document provides technical data about a liquid concentrate called Ardrox 6345 used for cleaning the compressor stages of gas turbine engines by removing atmospheric impurities, oil, and oxidation products. It describes the product's appearance, density, pH, recommended use and dilution procedures, safety guidance, and disposal of waste waters.

Uploaded by

Eric Vincent
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
621 views2 pages

Ardrox 6345

The document provides technical data about a liquid concentrate called Ardrox 6345 used for cleaning the compressor stages of gas turbine engines by removing atmospheric impurities, oil, and oxidation products. It describes the product's appearance, density, pH, recommended use and dilution procedures, safety guidance, and disposal of waste waters.

Uploaded by

Eric Vincent
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Gas Turbine Compressor Cleaner Overview
  • Application and Safety Information
  • Technical and Safety Details

Technical Data Sheet

Ardrox 6345

Gas turbine compressor cleaner

Scope
ARDROX 6345 is a liquid concentrate, which consists of an aqueous blend of non-ionic surface active
agents and corrosion inhibitors.
ARDROX 6345 is intended for use in the 'in-situ' washing of the compressor stages of gas turbine
engines. It is designed to remove the accumulation of atmospheric impurities, oil and oil oxidation
products that occurs in the compressor of such engines and so restore the power loss caused by these
deposits.

Chemicals required
ARDROX 6345

Method of use
ARDROX 6345 is used diluted with water in the proportion of 1 part product plus 4 parts water. The
product has a low trace analysis of inorganic impurities and, in order that the working solution applied to
the compressor is equally low in such impurities, ARDROX 6345 must be diluted with good-quality
distilled or deionised water only.
The ARDROX 6345 solution is sprayed into the cranked or fired engine, according to the engine
manufacturers' approved method, using the equipment and technique appropriate to the engine being
cleaned. The volume of solution required and the flow rate will depend on engine type.

CAUTION
Some manufacturers do not permit any solutions to be sprayed into a running, or fired, engine : refer to
the appropriate maintenance procedures.
After cleaning, the engine should be rinsed with distilled or deionised water and then protected with
water-displacing fluid, ARDROX 3961, unless the engine is to be used immediately.

Effects on materials
When used as recommended, ARDROX 6345 is non-corrosive to the materials normally used in gas
turbine engine construction. It is also non-corrosive to the alloys and paint schemes normally used in
airframe construction. It will not craze or discolour polymethylmethacrylate plastic or cause hydrogen
embrittlement.
Ardrox 6345

Technical information
Appearance: Clear, yellow, mobile liquid.
Density: 1.02 g/ml at 20C
pH: 8.5 (product as supplied)
These are typical values only and do not constitute a specification.

Equipment materials
Equipment/tanks can be constructed of 316 or 320 stainless steel.

Safety guidance
Before operating the process described it is important that this complete document, together with any
relevant Safety Data sheets, be read and understood.

General information
Chemetall PLC supplies a wide range of chemical products and associated equipment for cleaning,
sanitising, descaling, paint and carbon removal, metal protection and non-destructive testing. Sales
Executives are available to advise on specific problems and applications.

Labour and environmental protection


All local and national regulations on the transport, storage, use and waste treatment of chemicals in
concentrated or diluted form and as working solutions must be obeyed.
Further specific information on the products can be found in the EC Safety Data Sheets supplied. The
user should also pay strict attention to information and hazard symbols shown on product labels.

Waste disposal
All waste waters must be treated in accordance with national legislation and local regulations prior to
discharge to the sewer.

lc Feb 2001 (Amend July 04)

Page 2/2
 registered trademark Chemetall PLC
The above data have been compiled to the best of our knowledge on the basis of thorough tests and with regard to the current state Denbigh Road, Bletchley, Milton Keynes MK1 1PB
of our long practical experience. No liabilities or guarantee deriving from or in connection with this leaflet can be imputed to us. Tel: (01908) 649333 • Fax: (01908) 373939
Reproduction, in whole or in part, only with our express permission.
e-mail: [email protected] • www.chemetall.com