0% found this document useful (0 votes)
314 views2 pages

Mk6Es Factsheet English

The Mk6Es smart meter emphasizes robust external impulse protection and internal data security while offering flexible electrical performance monitoring. It has multiple measurement capabilities, communication options, and security features like tamper detection and multi-level access controls.

Uploaded by

Dary Arroyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
314 views2 pages

Mk6Es Factsheet English

The Mk6Es smart meter emphasizes robust external impulse protection and internal data security while offering flexible electrical performance monitoring. It has multiple measurement capabilities, communication options, and security features like tamper detection and multi-level access controls.

Uploaded by

Dary Arroyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

[Link]-meters.

com

Mk6Es
– Class 0.2S and Class 0.5S

Security Assurance Smart Meter

The Mk6Es is a Class 0.2S active and Class 0.5S


reactive smart meter that emphasize on robust
external 12kV impulse safety protection and internal
data security protection while offering flexible and
programmable monitoring of electrical performances
for various application challenges in present
industries.

Key Features

Mk6Es Factsheet | MKT-FS-059 Rev 05 Copyright © 2021 EDMI Limited


175mm (W)

Mk6Es
- Class 0.2S and Class 0.5S
292.5mm (H) 93mm (D)

Security Assurance Smart Meter

Weight: 2.2 kg

Standards and Compliance • 6 x BOSFET outputs (240V, • W, var, VA Calendar - RS 485 (2 or 4-wire RJ45 or 2
100mA maximum) • True RMS voltage and current • Supports Daylight Saving time or 4-wire screw terminal
• Class 0.2S Active and
Class 0.5S Reactive (3 phase + neutral) • Extension card features:
• IEC 62052-11, 62053-22, Battery • CT and VT correction Tamper Detection and - 2x RJ45 RS-485
62053-24, 62059-32-1, SP-1618 • External lithium thionyl • Transformer and line loss Alarms - 1x 2-wire RS-485/1x4-wire
chloride battery (3.6V, compensation RS-485
• Multiple tamper detection
Measurement 1200mAh) • Power factor, frequency, - 2x Active I/P (5VDC)/2xSO
options
• 3 phase 3 wire • Internal super capacitor (5V) phase angles O/P (27VDC, 20mA rated)
• Provision for sealing with
• Backup time: 72 hours without • GSM/GPRS supported
• 3 phase 4 wire conventional wire or plastic
power (super capacitor) Power Quality
• Option for neutral current seals • Built-in Ethernet Port
• Read-Without-Power(optional):
measurement • Power frequency • Pre-configured alarms self- (10/100Mbps)
Nickel metal hydride (NiMH)
• Magnitude of supply voltage check • Supports local and remote
battery (3.6V, 500mAh, Charge
Voltage cycle: 1000 times) • Supply voltage sag and swell • Alarms trigger LEDs and/or upgrade and configurations
• Nominal voltage: • Voltage interruption communication event
• Backup time: 10 years without
57 - 240V L-N/100V - 415 L-L or power (lithium battery) • Unbalance supply voltage Protocol
57 - 277V L-N/100V - 480 L-L
Security
• Voltage harmonics • EDMI command line
• Impulse voltage: 12kV • Multi-level security (username
Real-time Clock • Voltage total harmonics
and password including
• DLMS/COSEM
• Terminal size: Ø 3.2mm - • Precision clock accuracy: distortion (THD)
encrypted log-in) • MODBUS (RTU)
3.3mm <5ppm (15 seconds per
• Up to 7 independent levels • DL/T-645:2007
month) at full temperature Load Survey/Profile
Current range (-40°C to +85°C) • Up to 6 individual users
• Up to 70 channels and 2
• CT range: • RTC and frequency independent surveys
0.3/6A, 1/6A, 1/10A, 5/10A, synchronisation • Intervals programmable from Advanced Security Software
5/20A • Mains synchronised or 1 minute to 1 month • On-chip AES-128 • EDMI EziView software
internal crystal time keeping • 30 days storage (70 • Secure boot
• CT limit: 20 x Imax for 0.5 available for meter
with revert channels, 30 minute interval)
seconds programming and reading
• Terminal size: Ø 6.4mm -
• 120 days storage (15 Script Extensions (Windows® compatible)
6.6mm
Data Memory channels, 30 minute interval) • Mk6Es Genius meter • EDMI MultiDrive software
• 16MB of non-volatile memory • Energy, instantaneous continues the adaptable available for large scale AMI
readings, pulsing inputs as concept of meter“extensions”,
Auxiliary Supply Option and AMR solutions
Display channel sources introduced in the original MK6 (Windows® compatible)
• 100 to 240 VAC/140 to 340 • Ability to store average/
• Display digit size: 9mm x Genius using EziScript,
VDC minimum/maximum values for
5.2mm complex register manipulations
• Auxiliary only input/Auxiliary interval duration
• 16 Characters by 3 lines can be performed allowing
priority/Phase priority Environmental
alphanumeric display sophisticated processing
• Specified operating range:
• Programmable units, multpliers Time of Use capabilities.
Power Consumption -25˚C to +60˚C
and leading zeros • Up to 8 rates plus unified rate • Standard toolbox extensions
• Voltage circuit: <10VA/phase provided • Operating range limit:
•D
 isplays any available meter • Up to 32 separate import and
@ Vn • Customer-specific extensions -40˚C to +70˚C
parameter export registers
• Current circuit: <0.5VA/phase will be made to order • Storage range limit:
• Up to 64 user-defined screen • Daily, weekly, monthly, yearly
@ In pages to display any meter/ and special days -40˚C to +85˚C
energy parameter • Up to 200 programmable • Relative humidity:
Frequency special days Up to 75% mean, 95% non-
Communications
• 50Hz/60Hz • Up to 100 previous periods condensing for 30 days
• Up to 3 independently
plus period totals • Ingress protection: IP54
Measured Values working communication ports:
Inputs/Outputs • 3 elements, 4 quadrants • Block or rolling maximum - Optical port: FLAG (IEC • Salt spray resistance:
Configuration • Import/Export/Absolute Wh,
demand 62056-21) ASTM B117
• 2 x LED indicators + • Energy, pulsing inputs - RS-232 with modem power
varh and VAh
1 x Ethernet indicator • Per quadrant: Wh,varh and • Time of maximum demand supply (7W, 13VDC max) or
• 4 x passive inputs VAh Ethernet
(5VDC/12VDC/24VDC/48VDC • Phase A, B, C and Total
110VAC/240VAC)

EDMI Limited [Link]


(Headquarters)
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 Fax: +65 6756 0125
Email: marketing@[Link]
techsupport@[Link]
Copyright © 2021 EDMI Limited. All Rights Reserved. All trademarks are the property of their respective holders. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.