GAS SAMPLING SYSTEM

MM5001 TM
MM5001TM is a major technical leap forward in gas detection
technology. The system comprises of a central control cabinet
with a touch screen panel that displays gas concentrations
and alarm status. At the heart of the system is the main
PLC controller, gas analyser and a pre-sampling circuit. A
calibration-free, high performance infra-red sensor provides
the ultimate in reliable fl ammable gas analysis.MM5001TM is
fully compliant with IACS UR F43, Exxon MOBIL MESC 2002
term charter, Chapter 8.

• Calibration-free, infra-red gas sensors


• Fail-safe PLC control system
• Programmable operation during ballasting
• Up to 48 measuring points per cabinet
• Robust flow fail detection system
• Automatic self cleaning of sample lines
• Pre sampling purge reduces sample times

TECHNICAL SPECIFICATIONS
SAMPLE POINTS: 1~48 sample points per system, plus up to 16 fixed point sensor
SAMPLING TIME: Adjustable with integral pre-sampling to maximise cycle time efficiency
Flammable gas – 0-100% LEL
MEASUREMENT: 0-100% V/V, Oxygen gas – 0-25% VOL
H2S 0-50ppm, CO plus other gases
POWER SUPPLY: 110/230V ac 50/60Hz @ 5A
POWER CONSUMPTION: 100W (alarm condition)
LED INDICATORS: L1 low alarm, L2 high alarm, system fault, flow fail, system running, main power and standby power
USER INTERFACE: 3.8” touchscreen with 6 user keys for: alarm, menu, hold, skip, home and mute
ALARM SETTINGS: Each point is fully adjustable between zero and full scale
INTERNAL POWER SUPPLY: 24V dc @ 5A
AUDIBLE ALARM: – 98dB @ 38cm
DIMENSIONS: 1000mm (H) x 800mm (W) x 400mm (D)
WEIGHT: 99kg approximately
FINISH: Epoxy coated steel RAL 7035
INGRESS PROTECTION: IP55
FIXING DETAILS: Wall mount – 4 x M8 suitable fasteners
Material – stainless steel, cupro nickel, brass or copper. Typical size: 10mm OD / 8mm ID, 8mm
SAMPLE LINES:
OD / 6mm ID
SAMPLE PARTICULATE FILTER: Optional in-line or end of line filters
SAMPLE VENT: 12mm/10mm compression fitting and flame arrestor
SAMPLE LINE BLOWBACK: Optional facility with fixed/adjustable controls
PUMP: High reliability double headed vacuum diaphragm pump
OPERATING TEMPERATURE: -40ºC to +70ºC
RESPONSE TIME: Typically < 20 seconds
Sensor 1 L1, L2 and L3 gas alarms | Sensor 2 L1, L2 and L3 gas alarms | Sensor 3 L1, L2 and L3
RELAY OUTPUTS: gas alarms | Sensor 4 L1, L2 and L3 gas alarms | Common gas | Flow fail | Power fail | Cabinet
gas | System fault | All contacts rated 230V ac @ 5A