0% found this document useful (0 votes)
114 views12 pages

Portable Data Collectors Specifications

The Dynamix 2500 portable data collector is designed for condition monitoring and machinery vibration diagnostics. It has 4 input channels that can accept various sensor types, and performs fast Fourier transforms with configurable windows and filters. It stores vibration data and analysis results and can operate standalone or upload data to analysis software. Key specifications include high resolution data collection, extensive signal processing capabilities, large internal storage, and a durable design for field use.

Uploaded by

oliver bien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views12 pages

Portable Data Collectors Specifications

The Dynamix 2500 portable data collector is designed for condition monitoring and machinery vibration diagnostics. It has 4 input channels that can accept various sensor types, and performs fast Fourier transforms with configurable windows and filters. It stores vibration data and analysis results and can operate standalone or upload data to analysis software. Key specifications include high resolution data collection, extensive signal processing capabilities, large internal storage, and a durable design for field use.

Uploaded by

oliver bien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Technical Data

Portable Data Collectors Specifications

Catalog Numbers 1441-DYN25, 1441-DYN25-Z, EK-00383


A portable data collector is designed for condition-monitoring data collection,
analysis, and root cause correction in applications with rotating equipment, such
as motors, pumps, fans, and gear boxes.

Topic Page
Dynamix 2500 Portable Data Collectors 2
Dynamix 2500 Accessories 5
Enpac Ex Portable Data Collector 7
Enpac Ex Accessories 9
Portable Data Collectors Specifications

Dynamix 2500 Portable The Dynamix 2500 data collector is a real-time, multi-channel fast Fourier
transformer (FFT) analyzer and data collector for predictive maintenance and
Data Collector machinery vibration diagnostics. It is capable of measuring, processing,
displaying, and storing a wide range of analysis functions. It can operate as a
standalone instrument or you can download your measurements to your software
application for program analysis.

Table 1 - Technical Specifications - Dynamix 2500 Portable Data Collector


Attribute 1441-DYN25, 1441-DYN25-Z
Input channels Four
Input sources • Acceleration, velocity, and displacement from
hand-held or installed sensors or monitoring systems
• AC/DC sensors
• Pressure sensors
• Temperature sensors
• Keyboard entry measurements read from indicators
or installed instruments entered in engineering units
• Universal tachometer input accepts pulse inputs in
the range ± 25V
• Visual inspections added to measurement as coded
notes or typed-in text notes
Tachometer input parameters • TTL/analog programmable to ± 25V
• RPM range 1…99,999
• Dynamic range > 90 dB (24-bit ADC sigma-delta)
Input over-voltage protection • ± 50V AC, peak
• DC ± 50 V DC
Amplitude accuracy • ± 5%
Resolution Programmable 100, 200, 400, 800, 1600, 3200, 6400, or
25600 lines
Measurement windows • Hanning
• Hamming
• Flat top
• Rectangular
Multi-point automation Up to 12 measurements can be linked for one-button
automated data collection for each measurement
location
Preprocessing gSE and ESP enveloping (demodulator) with four
selectable input filters for enhanced bearing and gear
mesh fault detection
Input filters, gSE • 100 Hz
• 200 Hz
• 500 Hz
• 1 KHz
• 2 KHz
• 5 KHz
Input filters, ESP • 0.6…1.25 KHz
• 1.25…2.5 KHz
• 2.5…5 KHz
• 5…10 KHz
• 10…20 KHz

2 Rockwell Automation Publication 1441-TD001A-EN-P - July 2011


Portable Data Collectors Specifications

Table 1 - Technical Specifications - Dynamix 2500 Portable Data Collector


Attribute 1441-DYN25, 1441-DYN25-Z
Nonroute frequency range 2 Hz…80 KHz
Offroute frequency range 0 Hz…80KHz
(ICP coupled measurements limited to 0.16 Hz…80 KHz)

High pass: OFF (~0 Hz), 0.18 Hz, 0.36 Hz, 2 Hz, 2.67 Hz,
5.3 Hz, 10 Hz, 23.8 Hz, and 70 Hz
Low pass: 1 Hz…80 KHz
Low-frequency cutoff 0.18…70 Hz
Averaging Programmable from 1…4096
Spectral, synchronous time, peak hold, and continuous
Cursor • Fixed and cursor lock
• Single, harmonic, and peak pick
Trigger modes • Trigger: External or Laser Tach
• Trigger Level: Fixed or Automatic
• Ext Trig Slope: Amplitude and Slope
Data Displays Four-channel spectrum, four-channel time, phase table,
orbit, process, cross channel phase, dual spectrum, time
plots, and tri-axial plots
• Up to 12 bands (fixed or order base) downloadable
from host software
• Band alarms can be shown or hidden by user
selection
• Grid can be shown or hidden by user selection
System operating system Microsoft Windows CE
Processors Microprocessor Marvell Xscale PXA320 at 806MHz
DSP processor Motorola DSP56311
Communication USB with MicroSoft ActiveSync
Internal memory Internal RAM 128 MB
Application and user data 64 MB
Memory card Secure digital (SDHC) card up to 16GB
Battery Rechargeable lithium ion, cat. no. 1441-PEN25-BAT
Weight, approx. 715 g (1.52 lb)
Dimensions, approx. 186 x 93 mm (7.32 x 3.66 in) narrowest point
186 x 134 mm (7.32 x 5.28 in) widest point
Casing • 80% High Impact ABS and 20% polycarbonate
plastic
• Hand strap fixing either side of unit
Display • LCD, backlit color
• 1/4 VGA (240 x 320)
• 58 x 72 mm (2.28 x x 2.83 in) viewable
Input connectors • Connector A and Connector B are 7-pin LEMO
connectors
• Trigger input is a 7-pin Fischer connector
• Laser tachometer
• DC power in is on POWER/USB/TRIGGER input
connector. This connector cannot be used in
hazardous locations.
North American temperature code T4A
IEC temperature code T4

Rockwell Automation Publication 1441-TD001A-EN-P - July 2011 3


Portable Data Collectors Specifications

Table 2 - Environmental Specifications - Dynamix 2500 Portable Data Collector


Attribute 1441-DYN25, 1441-DYN25-Z
Temperature, operating -10…50 °C (14…122 °F)
Temperature, storage -20…60 °C (-4…140 °F)
Relative humidity 0…95% noncondensing
Vibration 2 g @ 10…500 Hz
Drop 2 m (to Mil-Std 810)
Sealing IP65 (dust and water proof)
Emissions Group 1, Class A

Table 3 - Certifications - Dynamix 2500 Portable Data Collector


Certification(1) 1441-DYN25 1441-DYN25-Z
cCSAus CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations.
See CSA file LR236028.
CE European Union 2004/108/IEC EMC Directive, compliant with:
• EN 61000-6-2; Industrial Immunity
• EN 61000-6-4; Industrial Emissions
C-Tick Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
Ex N/A European Union 94/9/EC ATEX Directive, compliant with:
• EN 60079-11, Explosive Atmospheres, Protection "i"
• EN 60079-0, General Requirements II 3 G Ex ic IIC T4 Gc
IEC Ex N/A • IEC 60079-11, Explosive Atmospheres, Protection "i"
• IEC 60079-0, General Requirements II 3 G Ex ic IIC T4 Gc
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

4 Rockwell Automation Publication 1441-TD001A-EN-P - July 2011


Portable Data Collectors Specifications

Dynamix 2500 Accessories The portable data collector is available individually (catalog number
1441-DYN25 or 1441-DYN25-Z) or as a kit (catalog number 1441-DYN25-2C
or 1441-DYN25-Z-2C). The kit includes the data collector and the following
accessories.

Table 4 - Accessories Included in a Dynamix 2500 Kit


Accessory Catalog Number
Operating system and information CD 1441-DYN25-CD
Global power supply 1441-DYN25-PS
Battery 1441-PEN25-BAT
Transit case 1441-PEN25-CASE-T
Communication cable USB power splitter 1441-PEN25-COMS-US
Hand strap 1441-PEN25-HS
Rubber bump sleeve 1441-PEN25-RBS

Individual accessories include these items.

Table 5 - Individual Dynamix 2500 Accessories


Accessory Catalog Number
Dust cap set for inputs 1441-DYN25-CAP
2-channel adapter cable 1441-DYN25-CBL2CH
Headset adapter cable 1441-DYN25-CBLHS
Operating system and information CD 1441-DYN25-CD
4-channel extension module 1441-DYN25-M4CH
2-plane balancing extension module 1441-DYN25-MBAL
Bump test extension module 1441-DYN25-MBMP
Frequency response extension module 1441-DYN25-MFRF
Time recorder extension module 1441-DYN25-MREC
Run up/coast down extension module 1441-DYN25-MRUC
Global power supply 1441-DYN25-PS
Spare battery 1441-PEN25-BAT
Transit case 1441-PEN25-CASE-T
Communication cable USB power splitter 1441-PEN25-COMS-US
Hand strap 1441-PEN25-HS
Neck strap 1441-PEN25-NS
Rubber bump sleeve 1441-PEN25-RBS
50 mV per G Zone II accelerometer kit 1441-PEN25-Z2-50
100 mV per G Zone II accelerometer kit 1441-PEN25-Z2-100

Rockwell Automation Publication 1441-TD001A-EN-P - July 2011 5


Portable Data Collectors Specifications

1441-PEN25-BAT Battery
Table 6 - 1441-PEN25-BAT Specifications
Attribute 1441-PEN25-BAT
Type Rechargeable lithium ion, cat. no. 1441-PEN25-BAT
Capacity 2600 mAh
Power 18.7 Wh
Gauge Battery capacity indicator, 8 hours
Rechargeable In unit or via an off-the-shelf external DC power supply

Accelerometers and Sensors

For standard accelerometers to use with the 1441-DYN25 data collector, see the
9000 Accelerometers Specifications Technical Data, publication 9000-TD001A.

When you select an accelerometer or sensor to use with the 1441-DYN25-Z data
collector, make sure the device meets the hazardous certification requirements.
For example, use one of these devices.
• Monitran accelerometer MTN/1100I, certificate BAS02ATEX1057X
• Wilcoxon accelerometer 793-35, certificate SIRA 03ATEX2109X
• Wilcoxon accelerometer 797-35, certificate SIRA 03ATEX2109X
• Compact instruments sensor MinVLSxxx/N, certificate
BAS02ATEX3259X

6 Rockwell Automation Publication 1441-TD001A-EN-P - July 2011


Portable Data Collectors Specifications

Enpac Ex Portable Data Enpac Ex portable data collector is specifically designed for hazardous areas
requiring intrinsic safety. It is a single channel, ATEX II 1G, EEx ia IIC T4
Collector certified data collector and analyzer that can be used in areas with high
concentrations of acetylene, hydrogen, ethylene, or propane, often without
obtaining a hot work permit.

Table 7 - Technical Specifications - Enpac Ex Portable Data Collector


Attribute EK-00383
Input channels One
Input sources • Accelerometers
• Velocity transducers
• Displacement probes
• Photo-optical pickups
• DC inputs
• Keyboard entry
Signal inputs • ICP (20V @ 3.5 mA)
• AC signal
• DC signal
• Tachometer
Measurement parameters • Acceleration
• Velocity
• Displacement
• gSE
• ESP
• Temperature
• Phase
• Voltage
• User specified
Measurement types • Overall
• Spectrum
• Time waveform
• Phase
• Order normalized
• Spectral band alarm
Machine Identification • Plant
• Train
• Machine and point ID
• Point description
• Units
• Alarm levels
• Previous measurements,
• Alarm types
Input signal range • Non ICP ±12 V or 0…24 V
• ICP 0…20 V
Transducer check Bias voltage integrity
Signal • RMS
• Peak
• Peak to peak
• True peak
• True peak to peak
Auto range Yes
Dynamic range 85 dB typical (20-bit sigma delta ADC)
Frequency range, max DC to 40 kHz
Integrated 2.5 Hz (5% by 10 Hz)
High pass filters 2 Hz hardware filter

Rockwell Automation Publication 1441-TD001A-EN-P - July 2011 7


Portable Data Collectors Specifications

Table 7 - Technical Specifications - Enpac Ex Portable Data Collector


Attribute EK-00383
Bearing condition • gSE 100, 200, 500, 1000, 2000, 5000 Hz
• ESP 0.6…1.25, 1.25…2.5, 2.5…5,
5…10,10…20 kHz
Real time rate 40 kHz
FFT resolution 100…12,800 lines
Time block length 256…16,384 samples
Averaging Spectral, synchronous time, peak hold, and continuous
Alarms • Overall
• Spectrum
Note codes 100 note codes (select up to 6)
System operating system Microsoft Windows CE
Processors MIPS R400
DSP Motorola 56307
Communication RS-232 (9-way, D-type plug)
Internal memory Operating system and applications 16 MB
User data 8 MB
Internal RAM 8 MB
Memory card Secure Digital (SD) card up to 16GB
Battery Rechargeable lithium ion, catalog number EK-48624
Weight, approx. 850 g (1.6 lb)
Dimensions, approx. 186 x 93 mm (7.32 x 3.66 in) narrowest point
186 x 134 mm (7.32 x 5.28 in) widest point
Case • Faradex AX110 (ABS with stainless steel fibers)
• Hand strap fixing either side of unit
Display • LCD, backlit monochrome, touchscreen
• 1/4 VGA (240 x 320)
• 58 x 72 mm (2.28 x 2.83 in) viewable
Connectors • Signal input 4-pin Fischer 102 type
• Power in/battery charge 2-pin Fischer 102 type
• Trigger input 3-pin Fischer 102 type

Table 8 - Environmental Specifications - Enpac Ex Portable Data Collector


Attribute EK-00383
Temperature, operating -20…50 °C (-4…122 °F)
Temperature, storage -20…60 °C (-4…140 °F)
Relative humidity 0…80% noncondensing
Vibration 2 g @ 10…500 Hz
Drop 1 m (to Mil-Std 810)
Sealing IP65 (dust and water proof)
Emissions Group 1, Class A

8 Rockwell Automation Publication 1441-TD001A-EN-P - July 2011


Portable Data Collectors Specifications

Table 9 - Certifications - Enpac Ex Portable Data Collector


Certifications(1) EK-00383
CE European Union 2004/108/IEC EMC Directive, compliant with:
• EN 61000-6-2; Industrial Immunity
• EN 61000-6-4; Industrial Emissions
Ex European Union 94/9/EC ATEX Directive, compliant with:
• EN 60079-11, Explosive Atmospheres, Protection "i"
• EN 60079-0, General Requirements
• IEC 60079-26, Equipment with EPL Ga, II 1G, I M1, Ga Ex ia IIC T4 (Ta = -20…50 °C (-4…122 °F)),
Ma Ex ia I (Ta = 0…50 °C (32…122 °F))
IEC Ex • IEC 60079-11, Explosive Atmospheres, Protection "i"
• IEC 60079-0, General Requirements
• IEC 60079-26, Equipment with EPL Ga, II 1G, I M1, Ga Ex ia IIC T4 (Ta = -20…50 °C (-4…122 °F)),
Ma Ex ia I (Ta = 0…50 °C (32…122 °F))
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Enpac Ex Accessories
Table 10 - Enpac Ex Accessories
Accessory Cat. No.
50 mV/g accelerometer kit EK-48622
100 mV/g accelerometer kit EK-48635
RS-232 cable 1441-PEN25-COMS-RS
Accelerometer cable for BNC EK-48634
Accelerometer cable for Fischer EK-48626
Trigger cable Fischer EK-48636
Stylus EK-46217
Soft case 1441-PEN25-SCH
Service case 1441-PEN25-CASE-S
Neck strap 1441-PEN25-NS
Hand strap 1441-PEN25-HS
Accelerometer EK-48623
EK-48620
Power supply (PSU-7) EK-48624
Magnetic mount EK-48629
Soft case EK-48630

Rockwell Automation Publication 1441-TD001A-EN-P - July 2011 9


Portable Data Collectors Specifications

Battery
Table 11 - Enpac Ex Battery Specifications
Attribute Enpac Ex Battery
Type Rechargeable NiMH pack
Capacity 1800 mAh
Power 18.7 Wh
Gauge Battery capacity indicator, 8 hours
Rechargeable Internal via power adapter

10 Rockwell Automation Publication 1441-TD001A-EN-P - July 2011


Portable Data Collectors Specifications

Notes:

Rockwell Automation Publication 1441-TD001A-EN-P - July 2011 11


Important User Information
Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety
Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from
your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some
important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference,
and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment
must satisfy themselves that each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.

Documentation Feedback

Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this
document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.

Rockwell Automation, Rockwell Software, Allen-Bradley, ControlLogix, Logix5000, and Tech-Connect are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication 1441-TD001A-EN-P - July 2011


Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.