0% found this document useful (0 votes)
83 views3 pages

PSP-600 Series Power Supply Specs

The document provides specifications for a 600W power supply unit with parallel function. It includes details on the unit's voltage, current, power, protections, temperature range, certifications and other technical specifications.

Uploaded by

Bruno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views3 pages

PSP-600 Series Power Supply Specs

The document provides specifications for a 600W power supply unit with parallel function. It includes details on the unit's voltage, current, power, protections, temperature range, certifications and other technical specifications.

Uploaded by

Bruno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

600W with PFC and Parallel Function PSP-600 series

Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
With DC OK Signal output
Current sharing up to 2400W(3+1)
Built-in remote ON-OFF control
Built-in remote sense function
Fixed switching frequency at PFC:88KHz PWM:100KHz
3 years warranty

SPECIFICATION
MODEL PSP-600-5 PSP-600-12 PSP-600-13.5 PSP-600-15 PSP-600-24 PSP-600-27 PSP-600-48
DC VOLTAGE 5V 12V 13.5V 15V 24V 27V 48V
RATED CURRENT 80A 50A 44.5A 40A 25A 22.2A 12.5A
CURRENT RANGE 0 ~ 80A 0 ~ 50A 0 ~ 44.5A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 12.5A
RATED POWER 400W 600W 600W 600W 600W 600W 600W
RIPPLE & NOISE (max.) Note.2 180mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 300mVp-p
OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10 ~ 13.2V 12 ~ 15V 13.5 ~ 18V 20 ~ 26.4V 24 ~ 30V 41 ~ 56V
VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
LOAD REGULATION 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
SETUP, RISE TIME 1500ms, 50ms at full load
HOLD UP TIME (Typ.) 20ms at full load
VOLTAGE RANGE Note.5 88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) 0.95/230VAC 0.99/115VAC at full load
INPUT EFFICIENCY(Typ.) 79% 84% 85% 85% 86% 86% 87%
AC CURRENT (Typ.) 6.8A/115VAC 3.4A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 40A/230VAC
LEAKAGE CURRENT <1.3mA/240VAC
105 ~ 135% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V
OVER VOLTAGE
PROTECTION Protection type : Shut down o/p voltage, re-power on to recover
+5V: 95 (TSW1) detect on heatsink of power transistor; 95 (TSW51) detect on heatsink of power diode
OVER TEMPERATURE +12V ~ +48V: 85 (TSW1) detect on heatsink of power transistor; 80 (TSW51) detect on heatsink of power diode
Protection type : Shut down o/p voltage, re-power on to recover
REMOTE CONTROL RC+/RC-: Short = power on ; Open = power off
FUNCTION
POK SIGNAL PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V
WORKING TEMP. -20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50 )
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
MTBF 116.4K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 170*120*93mm (L*W*H)
PACKING 1.9Kg; 8pcs/15.5Kg/1.06CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:PSP-600-SPEC 2010-10-18
600W with PFC and Parallel Function PSP-600 series

Mechanical Specification Case No.910A Unit:mm

RS Connector(CN5) : JST B-XH or equivalent


Pin No. Assignment Mating Housing Terminal
1 RS+ JST XHP JST SXH-001T

58.3
2 RS- or equivalent or equivalent

direction
Air flow
Terminal Pin No. Assignment

100
2-M3 L=4mm max.
Pin No. Assignment
1 AC/L 2-M3 L=4mm max.
2 AC/N
3 FG
4 P(Current Share)
5 POK
6 R.C. G
150
7 R.C.
8~11 DC OUTPUT +V 185
12~15 DC OUTPUT -V
120 170

8 11.5 150

1 2 3 4 5 6 7

2-M3 L=4mm max. 2-M3 L=4mm max.

50

93
14 max.

12

CN5 8 9 10 11 12 13 14 15
9.5 11.5
Block Diagram PFC fosc : 88KHz
PWM fosc : 100KHz
FAN SIGNAL POK
CONTROL
CURRENT
SHARING P
CIRCUIT
ACTIVE RECTIFIERS RECTIFIERS
EMI INRUSH POWER +V
I/P CURRENT & &
FILTER P.F.C. SWITCHING FILTER -V
LIMITING
RC.G.
O.C.P. RC
FG DETECTION
PWM CIRCUIT
O.L.P.
CONTROL
O.V.P.

O.T.P.

Derating Curve Output Derating VS Input Voltage

Ta=25
100
100
Others
90
80
80

60 12V 70
50
LOAD (%)

60
LOAD(%)

40
50
20
40

-20 0 10 20 30 40 45 50 60 (HORIZONTAL) 88 100 115 135 155 230 264

AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz

File Name:PSP-600-SPEC 2010-10-18


600W with PFC and Parallel Function PSP-600 series

Control Terminal Instruction Manual

POK(+) RCG(-) RCG RC

L N FG P POK RCG RC L N FG P POK RCG RC L N FG P POK RCG RC

+V +V +V +V -V -V -V -V +V +V +V +V -V -V -V -V +V +V +V +V -V -V -V -V

RS+ RS- RS+ RS- RS+ RS-

+ - + - + -
LOAD LOAD LOAD

POK Signal Remote Sensing Remote Control


POK Signal is the voltage difference between Power ON: RCG and RC for short
"RCG" and "POK" pin output POK Signal for TTL level signal Power OFF: RCG and RC for open
PSU turn on: 3.3V ~ 5.6V
PSU turn off: 0V ~ 1V

Parallel Operation with Remote Sensing


(1)Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) :
(2)The voltage difference among each output should be minimized that less than 2% is required.
(3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)
=(The rated current per unit) x (Number of unit) x 0.9.
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
(5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit.
(6) When in parallel operation, the minimum output load should be greater than 3% of total output load.
(Min. load > 3% rated current per unit x number of unit)

LOAD

+V -V
+S -S

+ - P RC- RS+ RS- + - P RC- RS+ RS- + - P RC- RS+ RS- + - P RC- RS+ RS-

PSU PSU PSU PSU

File Name:PSP-600-SPEC 2010-10-18