Product Data Sheet

[Link]

Actuator
IA5
IA5 is a high speed AC powered linear actuator
designed with stainless steel extension tube,
which is suitable for various outdoor industrial
applications, such as construction machine,
air bridge, mining transportation conveyor…etc.
It also features its heavy load capability and
low current deviation. Ball Screw or ACME spindle
is available for users to choose.

Features and Options


Main application: Industrial, Agriculture
Standard features:
● Input voltage: 115V AC / 60Hz ; 230V AC / 50Hz
● Max. rated load: 3,500N (ACME) / 7,000N (Ball Screw)
● Max. static load: 4,500N (ACME) / 13,600N (Ball Screw)
● Max. speed at no load: 52.8mm/sec (Typical value)
● Stroke: 102 / 153 / 203 / 254 / 305 / 457 / 610mm
● IP level: IP54 (Static, non-action)
● Overload protection by clutch
● Extension tube material: Iron (for ACME) / stainless steel (for Ball Screw)
● Color: Black
● Power cord length: 600mm (with tinned wires)
● Duty cycle: 25%, max. 4 min. continuous operation in 16 min.
● Operating ambient temperature: -25°C ~ +65°C
● Certified: UL1004-1, CE Marking, EMC Directive 2014/30/EU

Options:
● Analog and absolute positioning feedback with Potentiometer (POT)
● Preset limit switches (LT)
● IP Ievel: IP65

1
Performance Data

ACME type
● 115V AC motor

Push / Pull * Typical Speed (mm/s) * Typical Current (A)


Model No. Gear ratio
Max. (N) No load Full load No load Full load
IA5-115-10-A-XXX 10:1 1500 26.5 22.9 2.8 3.1
IA5-115-20-A-XXX 20:1 2500 13.1 11.8 2.7 2.7
IA5-115-40-A-XXX 40:1 3500 6.6 6.0 2.7 2.7

Speed VS. Load Current VS. Load


30 6

25 5
10:1
20 4
Speed (mm/s)

Current (A)
15 3 10:1

20:1 20:1 40:1


10 2

40:1
5 1

0 0
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Load (N) Load (N)

● 230V AC motor

Push / Pull * Typical Speed (mm/s) * Typical Current (A)


Model No. Gear ratio
Max. (N) No load Full load No load Full load
IA5-230-10-A-XXX 10:1 1500 21.8 17.5 1.8 1.8
IA5-230-20-A-XXX 20:1 2500 10.8 9.3 1.9 1.9
IA5-230-40-A-XXX 40:1 3500 5.4 4.9 1.9 1.9

Speed VS. Load Current VS. Load

30 6

25 5

20 4
Speed (mm/s)

Current (A)

10:1
15 3

10 2
20:1 10:1 20:1 40:1
40:1
5 1

0 0
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500

Load (N) Load (N)

Remarks:
* The typical speed or typical current means the average value neither upper limit nor lower limit.
The performance curves are made with typical values.
2
Ball Screw type
● 115V AC motor

Push / Pull * Typical Speed (mm/s) * Typical Current (A)


Model No. Gear ratio
Max. (N) No load Full load No load Full load
IA5-115-05-B-XXX 5:1 2500 52.8 40.8 2.8 3.5
IA5-115-10-B-XXX 10:1 3500 26.5 22.9 2.8 3.1
IA5-115-20-B-XXX 20:1 4500 13.1 11.8 2.7 2.7
IA5-115-30-B-XXX 30:1 6000 8.7 7.9 2.7 2.7
IA5-115-40-B-XXX 40:1 7000 6.6 6.0 2.7 2.7

Speed VS. Load Current VS. Load


60 6

50 5

5:1
40 4
Speed (mm/s)

5:1

Current (A)
10:1
30 3 20:1 30:1 40:1
10:1
20 2

20:1
10 30:1 1
40:1
0 0
0 1000 2000 3000 4000 5000 6000 7000 0 1000 2000 3000 4000 5000 6000 7000
Load (N) Load (N)

● 230V AC motor

Push / Pull * Typical Speed (mm/s) * Typical Current (A)


Model No. Gear ratio
Max. (N) No load Full load No load Full load
IA5-230-05-B-XXX 5:1 2500 43.5 29.0 1.8 1.8
IA5-230-10-B-XXX 10:1 3500 21.8 17.5 1.8 1.8
IA5-230-20-B-XXX 20:1 4500 10.8 9.3 1.9 1.9
IA5-230-30-B-XXX 30:1 6000 7.2 6.3 1.9 1.9
IA5-230-40-B-XXX 40:1 7000 5.4 4.9 1.9 1.9

Speed VS. Load Current VS. Load


60 6

50 5

40 4
Speed (mm/s)

5:1
Current (A)

30 3

20 2
10:1 20:1 30:1 40:1
5:1 10:1
10 20:1 1
30:1
40:1 0
0
0 1000 2000 3000 4000 5000 6000 7000 0 1000 2000 3000 4000 5000 6000 7000
Load (N) Load (N)
Remarks:
* The typical speed or typical current means the average value neither upper limit nor lower limit.
The performance curves are made with typical values.
3
Dimensions
ACME type
● Retracted length (A)

Stroke (S)
Option
102 (4”) 153 (6”) 203 (8”) 254 (10”) 305 (12”) 457 (18”) 610 (24”)
Basic 262 313 364 414 465 668 821
POT 302 353 404 454 505 708 861
LT or LT+POT 359 410 460 511 613 765 918
(Tolerance: ±5mm)
● Drawing
- Basic

A S
77.2 24.5 65
17.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
151.7
157

82.5
ø87

ø25
Power wire

55.8 218.6 30.5 26

- With Potentiometer (POT)

A S
77.2 24.5 105
17.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
151.7
74.5
157

82.5
12.5
ø87
16.5

ø25
Power wires
ø21 Signal wires 28.1 96 218.6 30.5 26

- With limit switches (LT) or with both limit switches (LT) and Potentiometer (POT)
A S
77.2 24.5 105
23.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
151.7
74.5
157

82.5

25
ø87
16.5

ø25

ø21 ø25 30.5 96 218.6 30.5 52


Signal wires Power wires
Connecting wires
Unit: mm

4
Ball Screw type
● Retracted length (A)

Stroke (S)
Option
102 (4”) 153 (6”) 203 (8”) 254 (10”) 305 (12”) 457 (18”) 610 (24”)
Basic 302 353 404 455 506 735 888
POT 342 393 444 495 546 775 928
LT or LT+POT 399 450 501 552 680 832 985
(Tolerance: ±5mm)
● Drawing
- Basic

A S
77.2 24.5 65
17.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
151.7
157

82.5
ø87

Power wires ø25

55.8 218.6 30.5 26

- With Potentiometer (POT)

A S
77.2 24.5 105
17.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
157.1

151.7
74.5

82.5
12.5
ø87
16.5

ø25

ø21 Signal wires 28.1 96 218.6 30.5 Power wires 26

- With limit switches (LT) or with both limit switches (LT) and Potentiometer (POT)

A S
77.2 24.5 105
23.5 11.5
14 15
38.6

ø50.8

ø28.6
ø26

ø13 ø13
151.7
74.5
157

82.5

25
ø87
16.5

ø25

ø21 ø25 30.5 96 218.6 30.5 52


Signal wires Power wires
Connecting wires

Unit: mm

5
● Front connector
ACME type
- Basic or with Potentiometer (POT) - With limit switches (LT) or
with both limit switches (LT) and Potentiometer (POT)
17.5 11.5 23.5 11.5

Ø28.6
Ø13 Ø28.6 Ø13

Ball Screw type


- Basic or with Potentiometer (POT) - With limit switches (LT) or
with both limit switches (LT) and Potentiometer (POT)
17.5 11.5 23.5 11.5

Ø28.6
Ø28.6

Ø13 Ø13

● Rear connector
14 15
Ø26

Ø13

● Pivot orientation of rear connector

C3
C2
30°
30
° C1
30°

0° (Standard)
30°

30 C4
°

C5

Note: As an example in 0° orientation.

6
Cable with Flying Leads
Power wires
1. Basic or with Potentiometer type
● Gear ratio: 5:1 / 10:1 / 20:1

Red & White wires: Actuator extends


Power wires Red & Black wires: Actuator retracts
Green wire: Ground

● Gear ratio: 30:1 / 40:1

Red & Black wires: Actuator extends


Power wires Red & White wires: Actuator retracts
Green wires: Ground

2. With limit switches or with both limit switches and Potentiometer type
● Gear ratio: 5:1 / 10:1 / 20:1 / 30:1 / 40:1

Red & White wires: Actuator extends


Power wires Red & Black wires: Actuator retracts
Green wires: Ground

Signal wires
With Potentiometer (POT) absolute positioning feedback

White wire: Ground


POT wires Yellow wire: Vin
Blue wire: POT output

● Potentiometer specification: 10K ohm, 10 turns. Tolerance ±5%


● Output voltage: The voltage (resistance) between blue and white increases linearly from about 0 when the
actuator extends, and decreases when it retracts.

B W Y

Actuator extends

● There are different resolutions according to the stroke length (as table below)
Stroke (mm) Resistance (tolerance: ±0.3KΩ)

102 (4”) 0.3 ~ 8.1K


153 (6”) 0.3 ~ 8.7K
203 (8”) 0.3 ~ 9.2K
254 (10”) 0.3 ~ 7.4K
305 (12”) 0.3 ~ 8.8K
457 (18”) 0.3 ~ 9.4K
610 (24”) 0.1 ~ 9.9K

7
Compatibility

Product Model IA5 spec

Accessory MB30 mounting bracket (Fig. 1) • Standard, mounting hole ø13mm

Fig. 1

Certifications

IA5 actuator is compliant with the following regulations, in terms of the essential conformity requirements of
EMC Directive of 2014/30/EU.

Emission Immunity

EN IEC 61000-6-3:2021 EN IEC 61000-6-1:2019


EN IEC 61000-3-2:2019+A1:2021 IEC 61000-4-2:2008
EN 61000-3-3:2013+A1:2019 IEC 61000-4-3:2020
IEC 61000-4-4:2012
IEC 61000-4-5:2017
IEC 61000-4-6:2013
IEC 61000-4-8:2009
IEC 61000-4-11:2020

8
Ordering Key

IA5 - 230 - 20 - B - 102 - POT - LT - - - 2

115: 115V AC
Input voltage
230: 230V AC

05: 5:1 (Ball Screw only)


10: 10:1
Gear ratio 20: 20:1
30: 30:1 (Ball Screw only)
40: 40:1

A: ACME
Spindle type
B: Ball Screw

102: 102 mm (4”)


153: 153 mm (6”)
203: 203 mm (8”)
Stroke 254: 254 mm (10”)
305: 305 mm (12”)
457: 457 mm (18”)
610: 610 mm (24”)

Positioning Blank: None


feedback POT: Potentiometer

Blank: None
Limit switches
LT: Limit switches

Blank: IP54 (Standard)


IP level
IP65: IP65

Blank: 0° (Standard)
C1: 30°
Pivot orientation of
C2: 60°
Rear connector
C3: 90°
(Refer to Page 6)
C5: 120°
C4: 150°

Cable length 2: 600mm straight

More information about installation and usage is provided in IA5 User Guide, which can be downloaded from
Moteck website.

[Link]
Terms of Use
The user is responsible for application suitability of Moteck products. As ongoing improvement process continues, products listed on the Moteck website are subject to change without prior notice. Moteck
reserves the right to terminate the sales or remove any product displayed on the website, or listed in its catalogues.

©2022 Aug. MOTECK. MO-T-0143 Version: 3.0 9

You might also like