The document provides instructions for installing a new sensor PCB on two different types of gyro compasses. For compasses with a development status of E10 or higher, no modifications are needed. For older compasses below E10, several modifications are required including removing an existing bracket and noting that the plug location has changed before installing the new PCB. Installation should be tested and compass zero set after installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
279 views1 page

STD22 Sensor PCB Installation Guide

The document provides instructions for installing a new sensor PCB on two different types of gyro compasses. For compasses with a development status of E10 or higher, no modifications are needed. For older compasses below E10, several modifications are required including removing an existing bracket and noting that the plug location has changed before installing the new PCB. Installation should be tested and compass zero set after installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

R

Gyro Compass STANDARD 22


Type 110-233.NG001 Service Instructions
Hints for installation of the Sensor PCB
Sensor PCB Type 110-233.X11

Installation in Compasses with develeopment status E10 or higher

No modifications are necessary

Installation in Compasses with develeopment status <E10

The following modifications are necessary:


Read out and note the
alignment error.

Remove the defective PCB

Remove the mounting


bracket, which is mounted
between the PCB and the
compass supporting plate
(2 screws). The bracket will
no longer be required.

This fastening srew of the


new PCB is a longer type
and equipped with a nut.
Loosen this nut.

Note: The position of plug


for the ribbon cable to the
connection PCB has been
changed.

Install the PCB as the for-


mer type.
The longer screw must be
fixed with the nut on the
rear side of the compass
supporting plate.

If pulse log is connected: After final installation test


check the direction resp. po-
larity with dip switch B 37/4
(see service manual)
the complete system and
set the compass zero
(alignment error).
!
21.121 RA/S-SU 0509 EDITION 01 5.018891 Page 1 of 1