0% found this document useful (0 votes)
1K views4 pages

Singel Outdoor

1) Daikin has developed a new series of VRVIII cooling-only single outdoor units called RSXQ-P to expand sales in ASEAN residential markets. 2) The RSXQ-P units can connect to both VRV indoor units and residential air conditioner units using a BP conversion unit. 3) Key features of the RSXQ-P units include simplifying piping as single-use units and simplifying design for cooling-only function. Specifications including capacity, dimensions, and sound levels are provided for each model.

Uploaded by

Muhammad Wazir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views4 pages

Singel Outdoor

1) Daikin has developed a new series of VRVIII cooling-only single outdoor units called RSXQ-P to expand sales in ASEAN residential markets. 2) The RSXQ-P units can connect to both VRV indoor units and residential air conditioner units using a BP conversion unit. 3) Key features of the RSXQ-P units include simplifying piping as single-use units and simplifying design for cooling-only function. Specifications including capacity, dimensions, and sound levels are provided for each model.

Uploaded by

Muhammad Wazir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

You can access this information from our Web site

at "Distributor's Page" http://global.daikin.com/distributor/


No.NP11-06 Date: 1st September, 2011

Subject: New VRVIII cooling only type single outdoor unit series

[Development aim]
The newly developed VRVIII cooling only type single outdoor unit series enable mixed combination of VRV and
residential indoor units by connecting BP unit in order to expand sales in ASEAN residential market.
In addition, piping will be simplified by special model for cooling only type as single use.

[Appearance]
8,10 HP 12,14,16,18 HP NP11-06A 9th September, 2011
Rapid News NP11-06 “New VRVIII
cooling only type single outdoor unit
series” has been revised.
(The values of power consumption
have been corrected.)
Refer to Page 3.
RSXQ8/10P RSXQ12/14/16/18P

[Model series]
Production Target
Type Refrigerant Power supply Factory Base model New models
time market
RXQ8PAY18 RSXQ8PY1
RXQ10PAY18 RSXQ10PY1
RXQ12PAY18 RSXQ12PY1
ASEAN
RXQ14PAY18 RSXQ14PY1
RXQ16PAY18 RSXQ16PY1
RXQ18PAY18 RSXQ18PY1
RXQ8PAY13 RSXQ8PY15
RXQ10PAY13 RSXQ10PY15
RXQ12PAY13 RSXQ12PY15
Singapore
RXQ14PAY13 RSXQ14PY15
3 phase, RXQ16PAY13 RSXQ16PY15
4 wires, RXQ18PAY13 RSXQ18PY15
Cooling only R-410A Oct. 2011 DIT
380-415V, RXQ8PAY1S9 RSXQ8PY1S
50Hz RXQ10PAY1S9 RSXQ10PY1S
RXQ12PAY1S9 RSXQ12PY1S
Thailand
RXQ14PAY1S9 RSXQ14PY1S
RXQ16PAY1S9 RSXQ16PY1S
RXQ18PAY1S9 RSXQ18PY1S
RXQ8PAY12 RSXQ8PY14
RXQ10PAY12 RSXQ10PY14
RXQ12PAY12 RSXQ12PY14
Indonesia
RXQ12PAY12 RSXQ14PY14
RXQ16PAY12 RSXQ16PY14
RXQ18PAY12 RSXQ18PY14
*The end of model name "4", "5" or "S" is not written to Catalogue and Engineering Data Book for a management suffix.

-1-
[System lay-out]
The new RSXQ-P models enable mixed combination of VRV and residential indoor units by connecting BP unit.

NEW

Residential indoor units

VRV indoor units


RSXQ-P

[Connectable indoor units]


· Residential indoor units
Following residential indoor units are connectable by BP unit.
Type Model name 25 35 50 60 71

FCQ-BVE    

Ceiling-mounted cassette

FFQ-BV1B    

600 × 600

Ceiling-mounted built-in FBQ-BV1  

FDKS-EAVMB  
(700 mm width)
Duct-connected
FDKS-CAVMB  

FDKS-CVMB  
(900 / 1,100 mm width)

FTKS-DVM  
Wall-mounted
FTKS-FVM   

2 ports BPMKS967B2B
BP unit
3 ports BPMKS967B3B

· VRV indoor units


All current VRVIII indoor units, outdoor-air processing units and Heat Reclaim Ventilator (VAM/VKM) units can
be connected.
However, outdoor-air processing units and Heat Reclaim Ventilator (VAM/VKM) units cannot be connected
when mixed combination of VRV and residential indoor units.

-2-
[Changing points from base outdoor unit model ]
1) Limitation as single use
· Simplification of piping (Remove EV circuit, etc.)
2) Simplification by specialization for cooling only
· Simplification of piping and miniaturization of accumulator
3) Automatic charge and leak detection function are not mounted.
4) Selection method of indoor units
· The capacity of the VRV indoor unit decreases by the difference of control when mixed combination of
VRV and residential indoor units. Therefore, the capacity correction is necessary when VRV indoor unit is
selected. For selection method, refer to the Engineering Data.
5) Piping limitation
· Piping limitation will be changed. Refer to the Engineering Data for details.

[Specifications]
Model RSXQ8PY1 RSXQ10PY1 RSXQ12PY1 RSXQ14PY1 RSXQ16PY1 RSXQ18PY1
Power supply 3 phase, 4-wire system, 380-415V, 50Hz
Cooling capacity kcal/h(*1) 19,400 24,300 29,000 34,600 39,000 42,400
(*1)(*2) Btu/h(*1) 76,800 96,200 115,000 137,000 155,000 168,000
kW (*1) 22.5 28.2 33.7 40.2 45.3 49.3
kW (*2) 22.4 28.0 33.5 40.0 45.0 49.0
Power consumption (*2) kW 5.24 7.90 8.93 12.4 14.2 16.4 A
Capacity control % 20-100 14-100 14-100 10-100 10-100 9-100
Casing colour Ivory white (5Y7.5/1)
Compressor Type Hermetically sealed scroll type
Motor output kW 3.6×1 (1.4+4.5)×1 (1.8+4.5)×1 (1.4+4.5+4.5)×1 (2.7+4.5+4.5)×1 (2.8+4.5+4.5)×1
3
Airflow rate m /min 180 185 233 233 233 239
Dimensions (HXWXD) mm 1,680×930×765 1,680×1,240×765
Machine weight kg 188 232 268 312 312 324
Sound level dB(A) 57 58 60 60 60 63
Operation range Cooling °CDB -5 to 43
Refrigerant Type R-410A
Piping Liquid mm f9.5 (Brazing) f9.5 (Brazing) f12.7 (Brazing) f12.7 (Brazing) f12.7 (Brazing) f15.9 (Brazing)
connections Gas mm f19.1 (Brazing) f22.2 (Brazing) f28.6 (Brazing) f28.6 (Brazing) f28.6 (Brazing) f28.6 (Brazing)
Max. number of connectable indoor units 13 16 19 22 26 29
Connection capacity ratio % 50-130
Note: Specifications are based on the following conditions;
· Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.
· Equivalent piping length: 7.5 m
· Level difference: 0 m
· Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

[Option list]
Type
RSXQ8PY1 RSXQ10PY1 RSXQ12PY1 RSXQ14PY1 RSXQ16PY1 RSXQ18PY1
Item
KHRP26M22H (Max. 4 branch)
REFNET KHRP26M22H (Max. 4 branch)
Distributive header KHRP26M33H (Max. 8 branch)
KHRP26M33H (Max. 8 branch)
piping KHRP26M72H (Max. 8 branch)
REFNET joint KHRP26A22T, KHRP26A33T KHRP26A22T, KHRP26A33T, KHRP26A72T
Auxiliary pipe set *1 KHFP22B8P KHFP22B10P KHFP22B12P KHFP22B16P KHFP22B18P
Central drain pan kit KWC26C280 KWC26C450
Refrigerant pipe filter kit BHF26A450F
Digital pressure gauge kit BHGP26A1
Note: *1 Auxiliary pipe sets are not attached to the outdoor units. If necessary, use the optional accessories.

-3-
[Compatibility]
· There is no interchangeability about base model of cooling only type multiple connection series (RXQ-PAY1)
and new models.

[Models to be abolished]
Current cooling only type VRVIII BP connection models RXQ10/12/14/16PAY1R7 will be abolished.

[Literatures]
Target area Book No. Issued date Language
Catalogue General PCV1131 Oct. 2011 English
Engineering data General ED341119 Nov. 2011 English

[Applicable standards and manual languages]


Display of country
Applicable Language
Power Target Symbol Symbol of origin
Model name Factory laws and
supply market marking labeling Packing
standards Label Manuals Label
case
· Design label
RSXQ-PY1 ASEAN *1 —   · English · English
· R-410A label
· Design label · English
RSXQ-PY14 3 phase, Indonesia *1 —   · English
4 wires, · R-410A label *2 · Indonesian *2
DIT
380-415V, · Design label
RSXQ-PY15 50Hz Singapore *1 —
· R-410A label
× × · English · English
· Design label · English
RSXQ-PY1S Thailand *1 —   · Thai
· R-410A label · Thai
*1: Base on the following laws and standard
· KHK
· IEC60335-2-40: 2002
*2: The Indonesian language display is added to the unit and packing case according to Indonesian commercial law
[22/M-DAG/PER/5/2010].

-4-

You might also like