  • Electrical Measurements: Lists various equipment and their calibration details related to electrical measurements, focusing on AC and DC currents and voltages.
  • Mechanical Measurements: Covers mechanical dimension measurements and instruments including precision levels, thickness gauges, and dimensioning tools.
  • Pressure and Temperature Measurements: Details equipment employed in pressure and temperature calibration, presenting methods for liquid, thermocouple, and resistance measurements.
  • Thermal Measurements: Addresses thermal calibration specifics, including methodologies for temperature measurement using digital techniques.

KAPITAL CALTECH SERVICES, PLOT NO.

- 471, SECTOR - 1 NEAR IMT CHOWK,


Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 1 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

Permanent Facility
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Current @ (50 Hz
1 Digital Multimeter by 1 A to 10 A 0.163 A to 0.243 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Current @ (50Hz
2 Digital Multimeter by 100 mA to 1 A 0.163 % to 0.163 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50 Hz
3 Digital Multimeter by 100 mV to 10 V 0.115 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50 Hz
4 Digital Multimeter by 100 V to 1000 V 0.104 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 2 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50Hz
5 Digital Multimeter by 10 V to 100 V 0.104 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50Hz
6 Digital Multimeter by 2 mV to 100 mV 2.380 % to 0.115 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING
7 DC Current Digital Multimeter by 1 mA to 100 mA 0.086 % to 0.064 %
CURRENT (< 1
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING
8 DC Current Digital Multimeter by 100 mA to 1 A 0.064 % to 0.102 %
CURRENT (< 1
Direct Method
GHZ)
(Measure)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
9 ALTERNATING 10 A to 20 A 0.094 % to 0.349 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 3 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
10 ALTERNATING 3 mA to 30 mA 0.122 % to 0.056 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
11 ALTERNATING 30 mA to 300 mA 0.056 % to 0.056 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
12 ALTERNATING 300 µA to 3 mA 0.183 % to 0.122 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
13 ALTERNATING 300 mA to 1 A 0.056 % to 0.071 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO- Using Fluke 5502A
TECHNICAL- Multi Product
14 ALTERNATING AC Current @ 50 Hz Calibrator with 50 20 A to 1000 A 0.720 % to 1.18 %
CURRENT (< 1 turn current coil by
GHZ) (Source) Direct Method
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ 50 Hz Multi Product
15 ALTERNATING 1 A to 10 A 0.071 % to 0.094 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 4 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ 50 Hz Multi Product
16 ALTERNATING 30 µA to 300 µA 0.534 % to 0.183 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
17 ALTERNATING 3 V to 30 V 0.037 % to 0.037 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
18 ALTERNATING 30 mV to 300 mV 0.193 % to 0.043 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
19 ALTERNATING 30 V to 300 V 0.037 % to 0.060 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
20 ALTERNATING 300 V to 1000 V 0.060 % to 0.061 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ 50 Hz Multi Product
21 ALTERNATING 300 mV to 3 V 0.043 % to 0.037 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 5 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ 50Hz Multi Product
22 ALTERNATING 1 mV to 30 mV 2.433 % to 0.193 %
to 1KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
23 ALTERNATING DC Current 10 A to 20 A 0.075 % to 0.778 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
24 ALTERNATING DC Current 3 mA to 30 mA 0.014 % to 0.013 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
25 ALTERNATING DC Current 30 mA to 300 mA 0.013 % to 0.013 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
26 ALTERNATING DC Current 300 mA to 1 A 0.013 % to 0.049 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
TECHNICAL- DC Resistance (for using Resistance
2 Mohm to 100
27 ALTERNATING Insulation Tester @ Box by Direct 3.522 % to 3.606 %
Mohm
CURRENT (< 1 500 V) Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 6 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Power Factor Multi Product 0.0068 PF to 0.0059
28 ALTERNATING 0.2 PF to 1 PF
(Lag/Lead) Calibrator by Direct PF
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
TECHNICAL- Using Fluke 8846A
Capacitance @ 1
29 DIRECT Digital Multimeter by 1 nF to 100 nF 5.20 % to 1.77 %
kHz
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
30 DIRECT Capacitance @ 1kHz Digital Multimeter by 1 µF to 100 µF 1.77 % to 2.48 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
31 DIRECT Capacitance @ 1kHz Digital Multimeter by 100 nF to 1 µF 1.77%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
32 DIRECT DC Current Digital Multimeter by 1 A to 10 A 0.087 % to 0.27 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
33 DIRECT DC Current Digital Multimeter by 10 µA to 100 µA 2.95 % to 0.0874 %
CURRENT Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 7 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
34 DIRECT DC Current Digital Multimeter by 100 µA to 1 A 0.0874 % to 0.086 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
35 DIRECT DC Voltage Digital Multimeter by 1 mV to 100 mV 0.411 % to 0.0084 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0034 % to 0.0051
36 DIRECT DC Voltage Digital Multimeter by 10 V to 100 V
%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0084 V to 0.0034
37 DIRECT DC Voltage Digital Multimeter by 100 mV to 10 V
%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0051 % to 0.0060
38 DIRECT DC Voltage Digital Multimeter by 100 V to 1000 V
%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
100 Kohm to 1
39 DIRECT Resistance ( 2 wire) Digital Multimeter by 0.0133 % to 0.059 %
Mohm
CURRENT Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 8 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
100 Mohm to 1000
40 DIRECT Resistance ( 2 wire) Digital Multimeter by 0.93 % to 2.32 %
Mohm
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
41 DIRECT Resistance (2 Wire) Digital Multimeter by 1 Kohm to 100 Kohm 0.013%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
1 Mohm to 100
42 DIRECT Resistance (2 Wire) Digital Multimeter by 0.059 % to 0.93 %
Mohm
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
43 DIRECT Resistance (4 Wire) Digital Multimeter by 1 ohm to 100 ohm 0.36 % to 0.0201 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
44 DIRECT Resistance (4 Wire) Digital Multimeter by 100 ohm to 1 Kohm 0.020 % to 0.013 %
CURRENT Direct Method
(Measure)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
45 DIRECT Capacitance 1 µF to 100 µF 0.414 % to 0.75 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 9 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
46 DIRECT Capacitance 1 nF to 10 nF 1.73 % to 0.41 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
47 DIRECT Capacitance 10 nF to 100 nF 0.41%
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
48 DIRECT Capacitance 100 nF to 1 µF 0.41%
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
49 DIRECT DC Current 1 µA to 300 µA 2.33 % to 0.54 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
50 DIRECT DC Current 1 A to 10 A 0.049 % to 0.075 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO- Using Fluke 5502A
TECHNICAL- Multi Product
51 DIRECT DC Current Calibrator with 50 20 A to 1000 A 0.78 % to 0.52 %
CURRENT turn current coil by
(Source) Direct Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 10 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
52 DIRECT DC Current 300 µA to 3 mA 0.54 % to 0.014 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using Sigma
DC Resistance (2 1 m ohm to 10 m
53 DIRECT Resistance Box by 1.3%
Wire & 4 Wire) ohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Sigma
DC Resistance (2 10 m ohm to 1000 m
54 DIRECT Resistance Box by 0.61%
Wire & 4 Wire) ohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- DC Resistance (for Using Sigma
100 Mohm to 200
55 DIRECT Insulation Tester @ Resistance Box by 4.3%
Gohm
CURRENT 500 V) Direct Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
56 DIRECT DC Voltage 1 mV to 300 mV 0.35 % to 0.008 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
57 DIRECT DC Voltage 3 V to 30 V 0.0061%
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 11 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0061 % to 0.0067
58 DIRECT DC Voltage 30 V to 300 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0081 % to 0.0061
59 DIRECT DC Voltage 300 mV to 3 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0067 % to 0.0066
60 DIRECT DC Voltage 300 V to 1000 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
61 DIRECT Resistance ( 2 wire) 1 Mohm to 10 Mohm 0.0186 % to 0.072 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 10 Kohm to 100
62 DIRECT Resistance ( 2 wire) 0.011 % to 0.014 %
Calibrator by Direct Kohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 100 Kohm to 1
63 DIRECT Resistance ( 2 wire) 0.014 % to 0.0186 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 12 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 100 Mohm to 1000
64 DIRECT Resistance ( 2 wire) 0.581 % to 1.79 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
65 DIRECT Resistance ( 4 wire) 10 ohm to 100 ohm 0.129 % to 0.027 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
66 DIRECT Resistance (2 Wire) 1 Kohm to 10 Kohm 0.034 % to 0.011 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 10 Mohm to 100
67 DIRECT Resistance (2 Wire) 0.072 % to 0.581 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
68 DIRECT Resistance (4 Wire) 1 ohm to 10 ohm 1.168 % to 0.129 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
69 DIRECT Resistance (4 Wire) 100 ohm to 1 Kohm 0.027 % to 0.034 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 13 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
J type Thermocouple Using Fluke
TECHNICAL-
(Temperature Temperature
70 TEMPERATURE -200 °C to 1200 °C 0.233°C
Calibrator /Process Scanner 1586A by
SIMULATION
meter) Direct Method
(Measure)
ELECTRO- K type
Using Fluke
TECHNICAL- Thermocouple
Temperature
71 TEMPERATURE (Temperature -200 °C to 1300 °C 0.325°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO- N type
Using Fluke
TECHNICAL- Thermocouple
Temperature
72 TEMPERATURE (Temperature -200 °C to 1300 °C 0.486°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO- R type
Using Fluke
TECHNICAL- Thermocouple
Temperature
73 TEMPERATURE (Temperature 0 °C to 1750 °C 0.881°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO-
RTD PT100 Using Fluke
TECHNICAL-
(Temperature Temperature
74 TEMPERATURE -200 °C to 600 °C 0.031°C
Calibrator /Process Scanner 1586A by
SIMULATION
meter) Direct Method
(Measure)
ELECTRO- S type
Using Fluke
TECHNICAL- Thermocouple
Temperature
75 TEMPERATURE (Temperature 0 °C to 1750 °C 0.858°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 14 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

J type Thermocouple
ELECTRO-
(Temperature Using Fluke 5502A
TECHNICAL-
Indicator/Controller/ Multi Product
76 TEMPERATURE -200 °C to 1000 °C 0.321°C
Data Calibrator by Direct
SIMULATION
Logger/Recorder/Pro Method
(Source)
cess Meter/RTD)
K type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
77 TEMPERATURE Indicator/Controller/ -200 °C to 1300 °C 0.463°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
N type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
78 TEMPERATURE Indicator/Controller/ -200 °C to 1300 °C 5.418°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
R type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
79 TEMPERATURE Indicator/Controller/ 0 °C to 1750 °C 0.659°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 15 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

RTD PT100
ELECTRO-
(Temperature Using Fluke 5502A
TECHNICAL-
Indicator/Controller/ Multi Product
80 TEMPERATURE -200 °C to 800 °C 0.266°C
Data Calibrator by Direct
SIMULATION
Logger/Recorder/Pro Method
(Source)
cess Meter/RTD)
S type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
81 TEMPERATURE Indicator/Controller/ 0 °C to 1750 °C 0.544°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
ELECTRO-
TECHNICAL- Using Fluke 8846A
82 TIME & Frequency @ 3V Digital Multimeter by 10 Hz to 100 Hz 0.082 % to 0.013 %
FREQUENCY Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
83 TIME & Frequency @ 3V Digital Multimeter by 100 KHz to 1 MHz 0.013%
FREQUENCY Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
84 TIME & Frequency @3V Digital Multimeter by 100 Hz to 1000 Hz 0.013%
FREQUENCY Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 16 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
85 TIME & Frequency @3V Digital Multimeter by 1000 Hz to 100 KHz 0.013%
FREQUENCY Direct Method
(Measure)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
86 TIME & Frequency @ 3V 10 Hz to 100 Hz 0.06 % to 0.007 %
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
87 TIME & Frequency @ 3V 100 Hz to 1000 Hz 0.007%
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
88 TIME & Frequency @ 3V 100 KHz to 1 MHz 0.007 % to 0.003 %
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
89 TIME & Frequency @ 3V 1000 Hz to 100 KHz 0.007%
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
TECHNICAL- Using Digital Time
Time
90 TIME & Calibrator by Direct 1 s to 600 s 0.007 s to 0.3 s
(Stopwatch/Timer)
FREQUENCY Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 17 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Digital Time
Time
91 TIME & Calibrator by Direct 600 s to 86400 s 0.3 s to 23 s
(Stopwatch/Timer)
FREQUENCY Method
(Source)
Tachometer-Non-
Contact Mode/
MECHANICAL-
Stroboscope/
92 ACCELERATION Using Tachometer 60 RPM to 1000 RPM 2.98 % to 0.4 %
tachometer
AND SPEED
calibrator/RPM
Indicator/Centrifuge
Tachometer-Non-
Contact Mode/
MECHANICAL-
Stroboscope/ 1000 RPM to 60000
93 ACCELERATION Using Tachometer 0.4 % to 0.2 %
tachometer RPM
AND SPEED
calibrator/RPM
Indicator/Centrifuge
MECHANICAL- Using Sound Level
94 Sound Level Meter 94 dB to 114 dB 0.5dB
ACOUSTICS Calibrator
MECHANICAL-
DIMENSION Angle Plate/Precision Using Precision
(BASIC Angle Plate# • Level, Dial Indicator,
95 Upto to 500 mm 7µm
MEASURING Flatness of working Surface plate ,
INSTRUMENT, faces Digital Height Gauge
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 18 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION Angle Plate/Precision Using Precision
(BASIC Angle Plate# • Level, Dial Indicator,
96 upto to 500 mm 7µm
MEASURING Parallelism of Surface plate, Digital
INSTRUMENT, opposite face Height Gauge
GAUGE ETC.)
MECHANICAL-
DIMENSION
Bevel Angle Using Angle gauge
(BASIC
97 Protractor (L.C 5 Set by Comparison upto to 360 ° 3.5min.
MEASURING
min) Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Angle Gauge
(BASIC Bevel Protractor (L.C
98 Set by Comparison 0 ° to 90 ° 2.1min.
MEASURING 0.05 deg.)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Bore gauge
(BASIC Using ULM by
99 (Transmission Up to 1 mm 1.0µm
MEASURING Comparison Method
verification only)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Coating Thickness
100 Using Standard Foils 100 µm to 1000 µm 7.2µm
MEASURING Gauge
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 19 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
(BASIC Coating Thickness
101 Using Standard Foils Up to 100 µm 1.6µm
MEASURING Gauge
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Angle Gauge
(BASIC Combination Set
102 set by Comparison 0 to 180 ° 35min.
MEASURING (L.C 1°)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Lever Dial
(BASIC Comparator Stand Gauge / Surface Up to 300 X 300
103 2.2µm
MEASURING (Flatness ) Plate by comparision mm
INSTRUMENT, method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Profile
(BASIC Projector & Digital
104 Cube Mould Up to 150 mm 35µm
MEASURING caliper by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Cylindrical Using ULM by Direct
105 Up to 20 mm 1.0µm
MEASURING Measuring Pin Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 20 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION Depth Gauge -
Using Slip Gauge Set
(BASIC Vernier/Dial/
106 & Length bar by Up to 300 mm 15.8µm
MEASURING Electronic (L.C 0.02
Comparison Method
INSTRUMENT, mm)
GAUGE ETC.)
MECHANICAL-
DIMENSION
using Slip gauge &
(BASIC Depth Micrometer
107 Length Bar by 0 to 300 mm 5.8µm
MEASURING (L.C 0.01 mm)
comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Dial gauge (Lever Using ULM by
108 0 mm to 0.14 mm 1.0µm
MEASURING Type) L.C-0.001 mm Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Dial gauge (Lever Using ULM by
109 0 mm to 0.2 mm 1.4µm
MEASURING Type) L.C-0.002 mm Compaison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Dial gauge (Lever Using ULM by
110 0 mm to 0.8 mm 5.9µm
MEASURING Type) L.C-0.01 mm Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 21 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Dial gauge (Plunger
(BASIC Using ULM By
111 Type) (L.C.-0.001 0 mm to 5 mm 1.2µm
MEASURING Comparison Method
mm)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Dial gauge (Plunger Using ULM by
112 0 to 50 mm 5.6µm
MEASURING Type)(L.C. 0.01 mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip gauge Set
(BASIC Electronic Probe (L.C
113 by Comparison Up to 25 mm 0.5µm
MEASURING 0.0001 mm)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Digital caliper
(BASIC Elongation Gauge /
114 by Comparison Up to 100 mm 6µm
MEASURING Flakiness Gauge
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Engineers Square/ Using Surface Plate,
(BASIC
115 TRY Square, ( Dial Indicator by up to 300 mm 5.6µm
MEASURING
Parallelsim) Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 22 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
(BASIC Using ULM by Direct
116 Feeler Gauge 0 to 2 mm 1.0µm
MEASURING Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Half Round Jaws Using ULM & Dial
(BASIC (Gauge Block Indicator with
117 Up to 10 mm 3.1µm
MEASURING Accessories) Magnetic stand by
INSTRUMENT, (Flatness, Width) Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Height Gauge using slip gauge set
(BASIC
118 (Dial/Vernier/Electro & caliper checker by 0 to 1000 mm 22.0µm
MEASURING
nic) (L.C 0.01 mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Height Gauge using slip gauge set
(BASIC
119 (Dial/Vernier/Electro & caliper checker by 0 to 300 mm 11.7µm
MEASURING
nic) (L.C 0.01 mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Height Gauge using slip gauge set
(BASIC
120 (Dial/Vernier/Electro & caliper Checker by 0 to 600 mm 17.1µm
MEASURING
nic) (L.C 0.01 mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 23 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Indisde Using Slip gauge Set
(BASIC
121 Micrometer(L.C 0.01 with accessories by 5 mm to 100 mm 8.8µm
MEASURING
mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Indisde
(BASIC Micrometer/Stick using ULM by
122 upto to 300 mm 8.8µm
MEASURING Micrometer (L.C 0.01 Comparison Method
INSTRUMENT, mm)
GAUGE ETC.)
MECHANICAL-
Using Slip Gauge Set
DIMENSION
Inside/Outside Dial & Caliper Checker/
(BASIC
123 Caliper L.C.: 0.01 Length Bar with 5 mm to 300 mm 9.6µm
MEASURING
mm Accessories
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Micrometer (Analog / Using Slip gauge Set
(BASIC
124 Digital) L.C 0.001 by Comparison 0 mm to 100 mm 1.5µm
MEASURING
mm Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Micrometer (Analog / Using Slip gauge Set
(BASIC
125 Digital) L.C 0.001 / Length Bar by 100 mm to 300 mm 2.4µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 24 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Using Slip gauge Set
(BASIC Micrometer (Analog /
126 & Length Bar by 300 mm to 600 mm 11.5µm
MEASURING Digital) L.C 0.01 mm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Micrometer Using slip gauge set
(BASIC
127 (Analog/digital)(L.C. by comparison 0 to 25 mm 1.0µm
MEASURING
0.001 mm) method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Micrometer Head Using ULM by
128 Up to 25 mm 5.8µm
MEASURING (L.C 0.01 mm) Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Micrometer Setting
(BASIC Using ULM by
129 Rod (Flat / Round Up to 100 mm 1.2µm
MEASURING Comparison Method
Ended) / Length Bar
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Micrometer Setting
(BASIC Using ULM by
130 Rod (Flat/Round 100 mm to 300 mm 2.5µm
MEASURING Comparison Method
Ended) / Length bar
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 25 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Plain Plug Gauge/
(BASIC Using ULM by
131 OD Master / Air Ring Up to 100 mm 1.4µm
MEASURING Comparison Method
Gauge
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Plain Ring Gauge /
(BASIC Using ULM by
132 Setting Ring gauge/ 100 mm to 150 mm 3.2µm
MEASURING Compariosn Method
Air Plug Gauge
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Plain Ring Gauge /
(BASIC Using ULM by
133 Setting Ring gauge/ 3 mm to 100 mm 1.5µm
MEASURING Comparison Method
Air Plug Gauge
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC
134 Radius Gauge Projector by Direct Up to 25 mm 10µm
MEASURING
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Snap Gauge/Dial
(BASIC Using ULM by
135 snap gauge / Gap 2 mm to 200 mm 2.2µm
MEASURING Comparison Method
gauge
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 26 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
(BASIC Using ULM by
136 Sphere Ball Up to 25 mm 1.2µm
MEASURING compariosn method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Electronic
(BASIC Spirit Level level meter ,Tilt Up to 300 mm(Base
137 8µm/m
MEASURING (Sensitivity 20µm/m) Table by comparison Length)
INSTRUMENT, method
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Standard Thickness Using ULM by Direct
138 Up to 1 mm 0.5µm
MEASURING foils Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC
139 Taper Plug Gauge Using ULM Up to 25 mm 1.5µm
MEASURING
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC Taper Scale (L.C 0.1
140 Projector By Up to 20 mm 57µm
MEASURING mm)
Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 27 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
(BASIC Taper Thread Plug
141 Using ULM Up to 25 mm 2.2µm
MEASURING Gauge
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using ULM & Dial
(BASIC Test Mandrel (Run
142 gauge lever Type by Up to 150 mm 2.5µm
MEASURING Out / Diameter)
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC
143 Test Sieve Projector by 0.03 mm to 4 mm 5µm
MEASURING
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Profile
(BASIC Projector & Digital
144 Test Sieve 4 mm to 70 mm 3.8µm
MEASURING Caliper by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Thickness Gauge Using slip gauge set
(BASIC
145 (Dial/Digital) (L.C by Comparison 0 mm to 10 mm 1.0µm
MEASURING
0.01 mm) Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 28 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
(BASIC Thread Measuring Using ULM by 0.17 mm to 6.35
146 1.0µm
MEASURING Wire Comparison Method mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC Thread Pitch Gauge
147 Projector by Direct Up to 6.0/60 mm,° 2µm, min
MEASURING (Pitch/ Flank Angle)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Thread Plug Gauge / Using ULM & Thread
(BASIC
148 Wear Check Plug Measuring Wire by 100 mm to 300 mm 3.2µm
MEASURING
Gauge Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Thread Plug Gauge / Using ULM & Thread
(BASIC
149 Wear Check Plug Measuring wire by Up to 100 mm 1.8µm
MEASURING
Gauge Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Thread Ring Gauge /
(BASIC Using ULM by
150 Wear Check Ring 3 mm to 100 mm 1.5µm
MEASURING Comparison Method
Gauge
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 29 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Using Slip gauge Set
(BASIC Ultrasonic Thickness
151 by Comparison up to 200 mm 70.3µm
MEASURING Gauge L.C (0.1 mm)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Surface
(BASIC Plate,Test Mandrel,
152 VEE BlocK Flatness upto to 200 mm 5.0µm
MEASURING Dial Indicator by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Surface
(BASIC VEE BlocK Plate,Test Mandrel,
153 up to 200 mm 4.9µm
MEASURING Parallelism Dial Indicator by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Surface
(BASIC Plate,Test Mandrel,
154 VEE BlocK Symmetry upto to 200 mm 9.6µm
MEASURING Dial Indicator by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Caliper
DIMENSION VERNIER CALIPER
Checker & Using Slip
(BASIC (L.C.:0.01
155 Gauge Set With 0 to 1000 mm 18.5µm
MEASURING mm)(DIAL/VERNIER/
Accessories by
INSTRUMENT, ELECTRONIC)
Comparison Method
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 30 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
Using Caliper
DIMENSION VERNIER CALIPER
Checker & Using Slip
(BASIC (L.C.:0.01
156 Gauge Set With 0 to 600 mm 16.3µm
MEASURING mm)(DIAL/VERNIER/
Accessories by
INSTRUMENT, ELECTRONIC)
Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Caliper
DIMENSION VERNIER CALIPER
Checker & Using Slip
(BASIC L.C.: 0.01 mm
157 Gauge Set With 0 to 300 mm 11.2µm
MEASURING (DIAL/VERNIER/ELEC
Accessories by
INSTRUMENT, TRONIC)
Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC
158 Wire Gauge Projector by Direct Up to 10 mm 4µm
MEASURING
Method
INSTRUMENT,
GAUGE ETC.)
Using Caliper
MECHANICAL- Linear / Vernier / Checker, gauge
DIMENSION Digital / Electronic block set ,dial
159 Up to 600 mm 9um
(PRECISION Height Gauge L.C.: indicator , surface
INSTRUMENTS) 0.0001 mm late by comparison
method
MECHANICAL- Using Digital
Analog/Digital
PRESSURE Pressure Gauge with
160 pressure gauge, 0 bar to 10 bar 0.05bar
INDICATING Pressure
Pressure transmitter
DEVICES Comparator Pump

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 31 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL- Using Digital


Analog/Digital
PRESSURE Pressure Gauge with
161 pressure gauge, 0 bar to 700 bar 0.8bar
INDICATING Pressure
Pressure transmitter
DEVICES Comparator Pump
MECHANICAL- Using Digital
PRESSURE Analog/Digital Pressure Gauge with
162 -1 bar to 0 bar 0.002bar
INDICATING Vacuum Gauge Vacuum Comparator
DEVICES Pump
SPRT with Temp.
Scanner Fluke
THERMAL- Liquid in Glass
163 1586A Low Temp. -40 °C to 250 °C 0.59 °C to 0.59 °C
TEMPERATURE Thermometer
Bath by Comparison
Method
RTD's,
Thermocouple with Using 4 Wire RTD
and without and SPRT and Digital
Indicator/Data Temperature
THERMAL-
164 Logger/ Recorder/ Scanner Fluke > 50 °C to 250 °C 0.14 °C to 0.14 °C
TEMPERATURE
Temperature Gauge/ 1586A low
Digital temperature bath by
Thermometer/Temp comparison Method
erature Transmitter
RTD's,
Thermocouple with Using 4 Wire RTD
and without and SPRT and Digital
Indicator/Data Temperature
THERMAL-
165 Logger/ Recorder/ Scanner Fluke -40 °C to 50 °C 0.14 °C to 0.14 °C
TEMPERATURE
Temperature Gauge/ 1586A low
Digital temperature bath by
Thermometer/Temp comparison Method
erature Transmitter

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 32 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

RTD's,
Thermocouple with
Using S type
and without
Thermocouple and
Indicator/Data
SPRT and Digital
Logger/ Recorder/
THERMAL- Temperature
166 Temperature Gauge/ > 250 °C to 1200 °C 1.88 °C to 1.88 °C
TEMPERATURE Scanner Fluke
Digital
1586A Dry Block
Thermometer/Temp
Furnace by
erature
comparison Method
Transmitter/Switche
s

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 33 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

Site Facility
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Current @ (50 Hz
1 Digital Multimeter by 1 A to 10 A 0.163 A to 0.243 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Current @ (50Hz
2 Digital Multimeter by 100 mA to 1 A 0.163 % to 0.163 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50 Hz
3 Digital Multimeter by 100 mV to 10 V 0.115 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50 Hz
4 Digital Multimeter by 100 V to 1000 V 0.104 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 34 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50Hz
5 Digital Multimeter by 10 V to 100 V 0.104 % to 0.104 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING AC Voltage @ (50Hz
6 Digital Multimeter by 2 mV to 100 mV 2.380 % to 0.115 %
CURRENT (< 1 to 1KHz)
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING
7 DC Current Digital Multimeter by 1 mA to 100 mA 0.086 % to 0.064 %
CURRENT (< 1
Direct Method
GHZ)
(Measure)
ELECTRO-
TECHNICAL-
Using Fluke 8846A
ALTERNATING
8 DC Current Digital Multimeter by 100 mA to 1 A 0.064 % to 0.102 %
CURRENT (< 1
Direct Method
GHZ)
(Measure)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
9 ALTERNATING 10 A to 20 A 0.094 % to 0.349 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 35 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
10 ALTERNATING 3 mA to 30 mA 0.122 % to 0.056 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
11 ALTERNATING 30 mA to 300 mA 0.056 % to 0.056 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
12 ALTERNATING 300 µA to 3 mA 0.183 % to 0.122 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ (50 Hz Multi Product
13 ALTERNATING 300 mA to 1 A 0.056 % to 0.071 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO- Using Fluke 5502A
TECHNICAL- Multi Product
14 ALTERNATING AC Current @ 50 Hz Calibrator with 50 20 A to 1000 A 0.720 % to 1.18 %
CURRENT (< 1 turn current coil by
GHZ) (Source) Direct Method
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ 50 Hz Multi Product
15 ALTERNATING 1 A to 10 A 0.071 % to 0.094 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 36 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Current @ 50 Hz Multi Product
16 ALTERNATING 30 µA to 300 µA 0.534 % to 0.183 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
17 ALTERNATING 3 V to 30 V 0.037 % to 0.037 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
18 ALTERNATING 30 mV to 300 mV 0.193 % to 0.043 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
19 ALTERNATING 30 V to 300 V 0.037 % to 0.060 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ (50 Hz Multi Product
20 ALTERNATING 300 V to 1000 V 0.060 % to 0.061 %
to 1KHz) Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ 50 Hz Multi Product
21 ALTERNATING 300 mV to 3 V 0.043 % to 0.037 %
to 1 KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 37 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
AC Voltage @ 50Hz Multi Product
22 ALTERNATING 1 mV to 30 mV 2.433 % to 0.193 %
to 1KHz Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
23 ALTERNATING DC Current 10 A to 20 A 0.075 % to 0.778 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
24 ALTERNATING DC Current 3 mA to 30 mA 0.014 % to 0.013 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
25 ALTERNATING DC Current 30 mA to 300 mA 0.013 % to 0.013 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
26 ALTERNATING DC Current 300 mA to 1 A 0.013 % to 0.049 %
Calibrator by Direct
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
TECHNICAL- DC Resistance (for using Resistance
2 Mohm to 100
27 ALTERNATING Insulation Tester @ Box by Direct 3.522 % to 3.606 %
Mohm
CURRENT (< 1 500 V) Method
GHZ) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 38 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Power Factor Multi Product 0.0068 PF to 0.0059
28 ALTERNATING 0.2 PF to 1 PF
(Lag/Lead) Calibrator by Direct PF
CURRENT (< 1
Method
GHZ) (Source)
ELECTRO-
TECHNICAL- Using Fluke 8846A
Capacitance @ 1
29 DIRECT Digital Multimeter by 1 nF to 100 nF 5.20 % to 1.77 %
kHz
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
30 DIRECT Capacitance @ 1kHz Digital Multimeter by 1 µF to 100 µF 1.77 % to 2.48 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
31 DIRECT Capacitance @ 1kHz Digital Multimeter by 100 nF to 1 µF 1.77%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
32 DIRECT DC Current Digital Multimeter by 1 A to 10 A 0.087 % to 0.27 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
33 DIRECT DC Current Digital Multimeter by 10 µA to 100 µA 2.95 % to 0.0874 %
CURRENT Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 39 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
34 DIRECT DC Current Digital Multimeter by 100 µA to 1 A 0.0874 % to 0.086 %
CURRENT Direct Method
(Measure)
ELECTRO-
Using Fluke HV
TECHNICAL-
Probe with Digital
35 DIRECT DC High Voltage 1 KV to 30 KV 6.7 % to 3.4 %
Multimeter by Direct
CURRENT
Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
36 DIRECT DC Voltage Digital Multimeter by 1 mV to 100 mV 0.411 % to 0.0084 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0034 % to 0.0051
37 DIRECT DC Voltage Digital Multimeter by 10 V to 100 V
%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0084 V to 0.0034
38 DIRECT DC Voltage Digital Multimeter by 100 mV to 10 V
%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
0.0051 % to 0.0060
39 DIRECT DC Voltage Digital Multimeter by 100 V to 1000 V
%
CURRENT Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 40 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
100 Kohm to 1
40 DIRECT Resistance ( 2 wire) Digital Multimeter by 0.0133 % to 0.059 %
Mohm
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
100 Mohm to 1000
41 DIRECT Resistance ( 2 wire) Digital Multimeter by 0.93 % to 2.32 %
Mohm
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
42 DIRECT Resistance (2 Wire) Digital Multimeter by 1 Kohm to 100 Kohm 0.013%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
1 Mohm to 100
43 DIRECT Resistance (2 Wire) Digital Multimeter by 0.059 % to 0.93 %
Mohm
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
44 DIRECT Resistance (4 Wire) Digital Multimeter by 1 ohm to 100 ohm 0.36 % to 0.0201 %
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
45 DIRECT Resistance (4 Wire) Digital Multimeter by 100 ohm to 1 Kohm 0.020 % to 0.013 %
CURRENT Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 41 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
46 DIRECT Capacitance 1 µF to 100 µF 0.414 % to 0.75 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
47 DIRECT Capacitance 1 nF to 10 nF 1.73 % to 0.41 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
48 DIRECT Capacitance 10 nF to 100 nF 0.41%
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
49 DIRECT Capacitance 100 nF to 1 µF 0.41%
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
50 DIRECT DC Current 1 µA to 300 µA 2.33 % to 0.54 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
51 DIRECT DC Current 1 A to 10 A 0.049 % to 0.075 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 42 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO- Using Fluke 5502A


TECHNICAL- Multi Product
52 DIRECT DC Current Calibrator with 50 20 A to 1000 A 0.78 % to 0.52 %
CURRENT turn current coil by
(Source) Direct Method
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
53 DIRECT DC Current 300 µA to 3 mA 0.54 % to 0.014 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using Sigma
DC Resistance (2 1 m ohm to 10 m
54 DIRECT Resistance Box by 1.3%
Wire & 4 Wire) ohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Sigma
DC Resistance (2 10 m ohm to 1000 m
55 DIRECT Resistance Box by 0.61%
Wire & 4 Wire) ohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- DC Resistance (for Using Sigma
100 Mohm to 200
56 DIRECT Insulation Tester @ Resistance Box by 4.3%
Gohm
CURRENT 500 V) Direct Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
57 DIRECT DC Voltage 1 mV to 300 mV 0.35 % to 0.008 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 43 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
58 DIRECT DC Voltage 3 V to 30 V 0.0061%
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0061 % to 0.0067
59 DIRECT DC Voltage 30 V to 300 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0081 % to 0.0061
60 DIRECT DC Voltage 300 mV to 3 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 0.0067 % to 0.0066
61 DIRECT DC Voltage 300 V to 1000 V
Calibrator by Direct %
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
62 DIRECT Resistance ( 2 wire) 1 Mohm to 10 Mohm 0.0186 % to 0.072 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 10 Kohm to 100
63 DIRECT Resistance ( 2 wire) 0.011 % to 0.014 %
Calibrator by Direct Kohm
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 44 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 100 Kohm to 1
64 DIRECT Resistance ( 2 wire) 0.014 % to 0.0186 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 100 Mohm to 1000
65 DIRECT Resistance ( 2 wire) 0.581 % to 1.79 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
66 DIRECT Resistance ( 4 wire) 10 ohm to 100 ohm 0.129 % to 0.027 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
67 DIRECT Resistance (2 Wire) 1 Kohm to 10 Kohm 0.034 % to 0.011 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product 10 Mohm to 100
68 DIRECT Resistance (2 Wire) 0.072 % to 0.581 %
Calibrator by Direct Mohm
CURRENT
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
69 DIRECT Resistance (4 Wire) 1 ohm to 10 ohm 1.168 % to 0.129 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 45 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
70 DIRECT Resistance (4 Wire) 100 ohm to 1 Kohm 0.027 % to 0.034 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
J type Thermocouple Using Fluke
TECHNICAL-
(Temperature Temperature
71 TEMPERATURE -200 °C to 1200 °C 0.233°C
Calibrator /Process Scanner 1586A by
SIMULATION
meter) Direct Method
(Measure)
ELECTRO- K type
Using Fluke
TECHNICAL- Thermocouple
Temperature
72 TEMPERATURE (Temperature -200 °C to 1300 °C 0.325°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO- N type
Using Fluke
TECHNICAL- Thermocouple
Temperature
73 TEMPERATURE (Temperature -200 °C to 1300 °C 0.486°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO- R type
Using Fluke
TECHNICAL- Thermocouple
Temperature
74 TEMPERATURE (Temperature 0 °C to 1750 °C 0.881°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
ELECTRO-
RTD PT100 Using Fluke
TECHNICAL-
(Temperature Temperature
75 TEMPERATURE -200 °C to 600 °C 0.031°C
Calibrator /Process Scanner 1586A by
SIMULATION
meter) Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 46 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO- S type
Using Fluke
TECHNICAL- Thermocouple
Temperature
76 TEMPERATURE (Temperature 0 °C to 1750 °C 0.858°C
Scanner 1586A by
SIMULATION Calibrator /Process
Direct Method
(Measure) meter)
J type Thermocouple
ELECTRO-
(Temperature Using Fluke 5502A
TECHNICAL-
Indicator/Controller/ Multi Product
77 TEMPERATURE -200 °C to 1000 °C 0.321°C
Data Calibrator by Direct
SIMULATION
Logger/Recorder/Pro Method
(Source)
cess Meter/RTD)
K type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
78 TEMPERATURE Indicator/Controller/ -200 °C to 1300 °C 0.463°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
N type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
79 TEMPERATURE Indicator/Controller/ -200 °C to 1300 °C 5.418°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 47 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

R type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
80 TEMPERATURE Indicator/Controller/ 0 °C to 1750 °C 0.659°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
RTD PT100
ELECTRO-
(Temperature Using Fluke 5502A
TECHNICAL-
Indicator/Controller/ Multi Product
81 TEMPERATURE -200 °C to 800 °C 0.266°C
Data Calibrator by Direct
SIMULATION
Logger/Recorder/Pro Method
(Source)
cess Meter/RTD)
S type
ELECTRO- Thermocouple
Using Fluke 5502A
TECHNICAL- (Temperature
Multi Product
82 TEMPERATURE Indicator/Controller/ 0 °C to 1750 °C 0.544°C
Calibrator by Direct
SIMULATION Data
Method
(Source) Logger/Recorder/Pro
cess Meter/RTD)
ELECTRO-
TECHNICAL- Using Fluke 8846A
83 TIME & Frequency @ 3V Digital Multimeter by 10 Hz to 100 Hz 0.082 % to 0.013 %
FREQUENCY Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
84 TIME & Frequency @ 3V Digital Multimeter by 100 KHz to 1 MHz 0.013%
FREQUENCY Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 48 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Fluke 8846A
85 TIME & Frequency @3V Digital Multimeter by 100 Hz to 1000 Hz 0.013%
FREQUENCY Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Fluke 8846A
86 TIME & Frequency @3V Digital Multimeter by 1000 Hz to 100 KHz 0.013%
FREQUENCY Direct Method
(Measure)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
87 TIME & Frequency @ 3V 10 Hz to 100 Hz 0.06 % to 0.007 %
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
88 TIME & Frequency @ 3V 100 Hz to 1000 Hz 0.007%
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
89 TIME & Frequency @ 3V 100 KHz to 1 MHz 0.007 % to 0.003 %
Calibrator by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Fluke 5502A
TECHNICAL-
Multi Product
90 TIME & Frequency @ 3V 1000 Hz to 100 KHz 0.007%
Calibrator by Direct
FREQUENCY
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 49 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

ELECTRO-
TECHNICAL- Using Digital Time
Time
91 TIME & Calibrator by Direct 1 s to 600 s 0.007 s to 0.3 s
(Stopwatch/Timer)
FREQUENCY Method
(Source)
ELECTRO-
TECHNICAL- Using Digital Time
Time
92 TIME & Calibrator by Direct 600 s to 86400 s 0.3 s to 23 s
(Stopwatch/Timer)
FREQUENCY Method
(Source)
Tachometer-Non-
Contact Mode/
MECHANICAL-
Stroboscope/
93 ACCELERATION Using Tachometer 60 RPM to 1000 RPM 2.98 % to 0.4 %
tachometer
AND SPEED
calibrator/RPM
Indicator/Centrifuge
Tachometer-Non-
Contact Mode/
MECHANICAL-
Stroboscope/ 1000 RPM to 60000
94 ACCELERATION Using Tachometer 0.4 % to 0.2 %
tachometer RPM
AND SPEED
calibrator/RPM
Indicator/Centrifuge
MECHANICAL-
DIMENSION
Bench Centre-
(BASIC Using Test Mandrel
95 Coaxiality of Up to 1000 mm 5µm
MEASURING & Lever Dial Gauge
Centres, (Flatness)
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 50 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL-
DIMENSION
Using Slip gauge set
(BASIC ULM (Single Axis
96 by Comparison 0 mm to 100 mm 1.4µm
MEASURING Machine)
Method
INSTRUMENT,
GAUGE ETC.)
Using Caliper
MECHANICAL- Linear / Vernier / Checker, gauge
DIMENSION Digital / Electronic block set ,dial
97 Up to 600 mm 9um
(PRECISION Height Gauge L.C.: indicator , surface
INSTRUMENTS) 0.0001 mm late by comparison
method
MECHANICAL- Using Glass Scale &
DIMENSION Profile Projector Slip Gauge set /
98 10 X to 50 X 1.5%
(PRECISION magnification Digital caliper by
INSTRUMENTS) compariosn method
MECHANICAL-
using angle gauge
DIMENSION Profile Projector
99 set by compariosn upto to 360 ° 75sec
(PRECISION Angular (1")
method
INSTRUMENTS)
MECHANICAL-
Profile Projector Using Glass Scale &
DIMENSION
100 Linear Dimension Slip Gauge Set by upto to 300 mm 3.1um
(PRECISION
(0.001 mm) Comparison Method
INSTRUMENTS)
MECHANICAL-
Vision Measuring
DIMENSION Using angle Gauge
101 Machine-Angular 0 ° to 360 ° 70sec
(PRECISION Set
Scale (LC:0.1")
INSTRUMENTS)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 51 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

MECHANICAL- Vision Measuring


Using Slip Gauge
DIMENSION Machine-Linear
102 and Glass Scale by upto to 200 mm 5.8um
(PRECISION Scale
comparison method
INSTRUMENTS) (LC:0.0001mm)
MECHANICAL- Using Digital
Analog/Digital
PRESSURE Pressure Gauge with
103 pressure gauge, 0 bar to 10 bar 0.05bar
INDICATING Pressure
Pressure transmitter
DEVICES Comparator Pump
MECHANICAL- Using Digital
Analog/Digital
PRESSURE Pressure Gauge with
104 pressure gauge, 0 bar to 700 bar 0.8bar
INDICATING Pressure
Pressure transmitter
DEVICES Comparator Pump
MECHANICAL- Using Digital
PRESSURE Analog/Digital Pressure Gauge with
105 -1 bar to 0 bar 0.002bar
INDICATING Vacuum Gauge Vacuum Comparator
DEVICES Pump
RTD's,
Thermocouple with Using 4 Wire RTD
and without and SPRT and Digital
Indicator/Data Temperature
THERMAL-
106 Logger/ Recorder/ Scanner Fluke > 50 °C to 250 °C 0.14 °C to 0.14 °C
TEMPERATURE
Temperature Gauge/ 1586A low
Digital temperature bath by
Thermometer/Temp comparison Method
erature Transmitter

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 52 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

RTD's,
Thermocouple with Using 4 Wire RTD
and without and SPRT and Digital
Indicator/Data Temperature
THERMAL-
107 Logger/ Recorder/ Scanner Fluke -40 °C to 50 °C 0.14 °C to 0.14 °C
TEMPERATURE
Temperature Gauge/ 1586A low
Digital temperature bath by
Thermometer/Temp comparison Method
erature Transmitter
RTD's,
Thermocouple with
Using S type
and without
Thermocouple and
Indicator/Data
SPRT and Digital
Logger/ Recorder/
THERMAL- Temperature
108 Temperature Gauge/ > 250 °C to 1200 °C 1.88 °C to 1.88 °C
TEMPERATURE Scanner Fluke
Digital
1586A Dry Block
Thermometer/Temp
Furnace by
erature
comparison Method
Transmitter/Switche
s
Temperature
Indicator /Controller
Using 4Wire RTD
with sensor of Liquid
and SPRT and Digital
bath/Dry Block
Temperature
THERMAL- Furnace/Environmen
109 Scanner Fluke -80 °C to 250 °C 0.15 °C to 0.15 °C
TEMPERATURE t Chamber/Deep
1586A by single
Freezer/Incubator/Re
point comparison
frigerator/Oven/Auto
Method
Clave/Cold
Room/Water Bath

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KAPITAL CALTECH SERVICES, PLOT NO. - 471, SECTOR - 1 NEAR IMT CHOWK,
Laboratory Name :
MANESAR, GURGAON, GURUGRAM, HARYANA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3186 Page No 53 of 53
Validity 08/12/2020 to 07/12/2022 Last Amended on -

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
[Link] Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrum

Temperature Using S type


Indicator /Controller Thermocouple and
with sensor of Liquid SPRT and Digital
THERMAL- bath/Dry Block Temperature
110 > 250 °C to 1200 °C 1.98 °C to 1.98 °C
TEMPERATURE Furnace Scanner Fluke
/Oven/Industrial 1586A by single
Furnace/Muffle point comparison
Furnace Method
* CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, using a coverage factor of k = 2.

This is annexure to 'Certificate of Accreditation' and does not require any signature.