L-500 Catalog

LP-Gas & Anhydrous Ammonia Equipment

A Regulators and Accessories

B Cylinder and Service Valves

C Multivalve® Assemblies

D Pressure Relief Valves and Relief Valve Manifolds

E Globe and Angle Valves

F Excess Flow, Check, Filler and Vapor Equalizing Valves

G Internal Valves and Accessories

H Adapters, Connectors and Fittings

J Miscellaneous Equipment (Including Rotogages and ESVs )


Foreword
This catalog describes a complete line of equipment available from Engineered Controls
International, Inc. for use with LP-Gas and anhydrous ammonia (NH3). The following points are
important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all
products within a product group are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service
pressure at temperatures of -40° F. to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service
as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they
have stainless steel materials).

Caution Notice
Installation, usage, and maintenance of all ECII® products must
Do not use any product contained in this catalog with any be in compliance with all Engineered Controls International,
service commodity other than LP-Gas or NH3. If you have Inc. instructions as well as requirements and provisions of
a need for use of another application, contact Engineered NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, state, provincial and local standards, codes, regulations, and
(336) 449-7707 before proceeding. laws.
Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning

All ECII ® products are mechanical devices that will


eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and ECII® LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many ECII® products are manufactured for storage, transport, in domestic systems.
transfer and use of toxic flammable and dangerous liquids and The use of an in-line filter should be considered when
gases. Such substances should be handled by experienced other system components may be unclean and the system
and trained personnel only, using accepted governmental contaminated by rust, scale, dirt, debris or other foreign
and industrial safety procedures. Never vent LP-Gas near any material.
possible source of ignition.
Determining the Age of Products
All ECII® products are mechanical devices that will eventually “lives.” The LP-Gas dealer knows better than anyone what this
become inoperative due to wear, contaminants, corrosion environment is.
and aging of components made of material such as metal and
rubber. Since 1960, most RegO® / ECII® products are identified with an
alphabetical code indicating the month and the year they were
The environment and conditions of use will determine the manufactured.
safe service life of these products. Periodic inspection and
maintenance are essential. Check the product for this code to determine age. If valves or
regulators are repainted, take care to keep the date code clear for
Because ECII® products have a long and proven record of quality later identification and inspection.
and service, LP-Gas dealers may forget the hazards that can occur
because products are used beyond their safe service life.
The life of a product is determined by the environment in which it

1960 to 1985 — Two-Letter Date Code Second letter in date code is the year
R — 1960 A — 1969 J — 1978
First letter in date code is the month S — 1961 B — 1970 K — 1979
A — January G — July T — 1962 C — 1971 L — 1980
B — February H — August U — 1963 D — 1972 M— 1981
C — March I — September V — 1964 E — 1973 N — 1982
D — April J — October W— 1965 F — 1974 O — 1983
E — May K — November X — 1966 G — 1975 P — 1984
F — June L — December Y — 1967 H — 1976 Q — 1985
Relief valves used on ASME tanks carry a numerical code Z — 1968 I — 1977
indicatingmonth and year such as 1-75 means January, 1975. EXAMPLE: DL = April of 1980

From 1985 to 1990 — Digit Date Code Second 2 digits in date code are the year
86 — 1986 89 — 1989
First digit in date code is the month 87 — 1987 90 — 1990
1 — January 7 — July 88 — 1988
2 — February 8 — August EXAMPLE: 5-87 = May of 1987
3 — March 9 — September
4 — April 10 — October
5 — May 11 — November
6 — June 12 — December

After 1990 — Digit-Letter-Digit Date Code Letter in date code is the week Second 2 digits in date code are the year
A — 1st week 91 — 1991 97 — 1997
First digit in date code is the month B — 2nd week 92 — 1992 98 — 1998
1 — January 7 — July C — 3rd week 93 — 1993 99 — 1999
2 — February 8 — August D — 4th week 94 — 1994 00 — 2000
3 — March 9 — September E — 5th week 95 — 1995 01 — 2001
4 — April 10 — October 96 — 1996 02 — 2002
5 — May 11 — November 03 — 2003 etcetera. . .
6 — June 12 — December EXAMPLE: 6A92 = First week of June, 1992

Regulator Color Coding


ECII® Domestic first stage, second stage, single stage, and integral in the field that can lead to accidents and costly service
twin stage LP-Gas regulators are easy to identify. In addition to the [Link] color coding system is standard on all 404, LV404,
standard part number marking which indicates the proper application, 2302,LV2302, 2403, 2503, LV4403, and LV5503 series domestic
each regulator is color coded to help minimize misapplication LPGas regulators manufactured after May of 1986.

Classic Gold — Indicates a single stage regulator that is designed to be used alone in single stage systems.
Brilliant Red — Denotes a first stage high pressure regulator, normally used in two-stage applications
in conjunction with a select brown second stage regulator.
Select Brown — Signifies second stage low pressure regulators, designed for use in two-stage systems in
conjunction with a brilliant red high pressure regulator — also signifies integral twin stage regulators
designed to provide benefits of two-stage regulation in one compact unit.
Select Blue — Indicates a second stage 2 PSIG delivery pressure regulator and a line pressure regulator downstream
to reduce 2 PSIG to appliance pressure
Green — High pressure pounds to pounds anhydrous amonia regulator.
Section Description
A Regulators and Accessories

B Cylinder and Service Valves

C Multivalve® Assemblies

D Pressure Relief Valves and Relief Valve Manifolds

E Globe and Angle Valves

F Excess Flow, Check, Filler and Vapor Equalizing Valves

G Internal Valves and Accessories

H Adapters, Connectors and Fittings

J Miscellaneous Equipment (Including Rotogages and ESVs )


Cross Reference by Part Number
12472.....................F11 2906D..................H11 A3184-90.................... H8 LV404B46................... A21 A5769H................................H9
12802.....................J17 2906E...................H11 3184-90.................... H8 LV404B46V9.............. A21 5769H................................H9
12982.................... H10 2906F...................H11 3185......................... H5 LV404B4V9................ A21 5769J.................................H9
100-HGD................J20 2906G..................H11 A3185........................ H5 LV404B9..................... A21 A5769K................................H9
10538P.................... H7 2962.....................A35 A3186...................... F25 LV404B96................... A21 5769K................................H9
1178.......................J19 302.......................A26 3188A.................... H10 LV404B96V9.............. A21 5769M................................H9
1183.......................J19 302S.....................A26 3188B................... H10 LV404B9V9................ A21 C5769N................................H7
1286.......................J19 302V.....................A26 3188C................... H10 LV404Y9..................... A24 5776...................................H8
1300...................... H11 302V9...................A26 3191........................ H5 LV4403-400................ A35 A5776...................................H8
1316WA.................J20 302V9LS..............A26 A3194-8R................ F20 LV4403B4................... A16 5807.................................A25
1328...................... H11 3119A.....................H6 3194-9..................... H8 LV4403B46................. A16 5808.................................A25
1331...................... H11 3120.......................H6 A3194-90................... H8 LV4403B46R.............. A16 5820.................................A25
1332...................... H11 3121.......................H6 3194-90................... H8 LV4403B66................. A16 5828.................................A25
1350E.................... A33 3125L...................D16 3194C................... F23 LV4403B66R.............. A16 5832.................................A25
1350R................... A33 AA3126L030.............D14 3195........................ H5 LV4403B66RA........... A17 597FA...............................A28
1450E.................... A33 AA3126L250.............D14 A3195........................ H5 LV4403B66RAB......... A17 597FB..............................A28
1450R................... A33 AA3126L312.............D14 3195-50..................J19 LV4403SR4................ A15 597FC..............................A28
1494-1................... H11 3127G..................D15 A3196...................... F25 LV4403SR9................ A15 597FD..............................A28
A1519A2..................F10 3127G..................D16 3197C................... F22 LV4403SR96.............. A15 6010..................................J11
1519A2..................F10 3127H..................D16 3199W................... A32 LV4403TR4................ A15 AA6010..................................J11
1519A3..................F10 3127J...................D16 3199W................... F16 LV4403TR9................ A15 6016..................................J10
A1519A4..................F10 3127K..................D15 3199W................... H10 LV4403TR96.............. A15 AA6016..................................J10
1519A4..................F10 3127K..................D16 3200C...................G13 LV4403Y4................... A19 6016-60D..........................J12
A1519A6..................F10 3127L...................D16 3200L....................G13 LV4403Y46R.............. A19 6024..................................J10
A1519B4..................F10 3127P...................D16 A3209D050...............G8 A4500Y8..................F14 AA6024..................................J10
1519B4..................F10 3127U..................D16 A3209D080...............G8 LV5503B4................... A18 612....................................J19
1519C2....................F9 3129G..................D15 A3209DT050.............G8 LV5503B6................... A18 612JS12...........................A32
1519C4....................F9 3129G..................D16 A3209DT080.............G8 LV5503B8................... A18 612JS20...........................A32
15774-1................. H11 3129H..................D16 A3212R105.............G15 LV5503G4.................. A20 612PS12..........................A32
AA1582MH................. A29 3129J...................D16 A3212R175.............G15 LV5503Y6................... A19 612PS20..........................A32
AA1582MK................. A29 3129K..................D15 A3212R250.............G15 LV5503Y8................... A19 LV6503B14..........................A20
AA1582ML................. A29 3129K..................D16 A3212RT105...........G15 5547.......................J19 LV6503B16..........................A20
AA1582MW................ A29 3129L...................D16 A3212RT175...........G15 5575.......................J19 6532A12.0.......................C10
AA1584MH................. A29 3129P...................D16 A3212RT250...........G15 5576.......................J19 6532R12.0.......................C10
1584MH................ A29 3129U..................D16 A3213R150.............G14 5726B23............... A23 6533A10.5.......................C10
X1584ML................. A30 AA3130UA250..........D14 A3213R200.............G14 5726B23............... A25 6533A11.7........................C10
AA1584ML................. A29 AA3130UA265..........D14 A3213R300.............G14 5727B23............... A23 6533R10.5.......................C10
1584ML................. A29 3131G..................D14 A3213R400.............G14 5727B23............... A25 6533R11.7........................C10
X1584MN................ A30 T3132G..................D14 A3213RT150...........G14 5754B4................. A23 6542A12.0.......................C10
1584MN................ A29 W3132G..................D14 A3213RT200...........G14 5754B4................. A25 6542R12.0.......................C10
AA1584MW................ A29 MV3132G..................D14 A3213RT300...........G14 5755B4................. A23 6543A11.1........................C10
AA1586MH................. A29 3132G..................D14 A3213RT400...........G14 5755B4................. A25 6543A11.7........................C10
1586MH................ A29 3133G..................D14 A3217FAL160...........G9 5760A.................... H11 6543R11.1........................C10
X1586ML.................... A30 3135G..................D14 A3217FAL210...........G9 5760B................... H11 6543R11.7........................C10
AA1586ML................. A29 AA3135UA250..........D14 A3217FAL260...........G9 5760C................... H11 6555R10.6.........................C9
1586ML................. A29 AA3135UA265..........D14 A3217FAL410...........G9 5760D................... H11 6555R11.6..........................C9
X1586MN................ A30 3139-18................A31 A3217FAR160...........G9 5760S.................... H11 6555R12.0.........................C9
1586MN................ A29 3139-26................A31 A3217FAR210...........G9 5760Z.................... H11 6579................................. F20
AA1586MW................ A29 3139-38................A31 A3217FAR260...........G9 5761A.................... H11 6584C.............................. F23
1588MH................ A29 3144-91..................H8 A3217FAR410...........G9 5761B................... H11 A6586D.............................. F26
1588ML................. A29 3144-9P.................H8 A3219FA400L......... G11 5761C................... H11 6586D.............................. F26
X1588ML0............... A30 3146..................... F25 A3219FA600L......... G11 5761D................... H11 6587EC............................ F22
X1588MN................ A30 A3146..................... F25 A3219RT.................G13 5763D..................... H9 TA7034LP............................ E10
1588MN................ A29 3146S................... F25 3226A-3.................J19 C5763N..................... H7 7034LP............................ E11
1708........................ H8 A3149G..................D14 3272E.....................F11 5764A...................... H9 TA7034P............................... E10
2070CO....................J6 A3149L050.............D14 3272F.....................F11 5764B..................... H9 7034P............................... E11
2071-L25.7...............J6 A3149L200.............D14 A3272G....................F11 5764C..................... H9 7053T................................. E8
2071-L39.7...............J6 3165C.................. J18 3272G....................F11 A5764D..................... H9 7141FP..............................H8
A2137.......................F13 3165CF................. J18 A3276BC................. F25 5764D..................... H9 7177..................................J13
A2137A....................F13 3165CF12.0......... J18 3282A.....................F11 A5764E..................... H9 7188..................................J13
2139.......................F13 3165S................... J18 3282B....................F11 5764E...................... H9 7188-21.............................J13
2139A.....................F13 3165SF12.0......... J18 A3282C....................F11 A5764W.................... H9 7188HS.............................J13
A2141A10..................J7 TA3169F12.0............. J18 3282C....................F11 A5765C..................... H9 7188MS.............................J13
A2141A16..................J7 3170..................... F24 A3292A....................F11 A5765D..................... H9 7193-4...............................J13
A2141A6....................J7 3171.......................H5 3292A.....................F11 5765D..................... H9 7193D-10..........................J13
A2141A6L..................J7 3171A.....................H5 A3292B....................F11 A5765E..................... H9 7193D-10..........................J15
A2141A8....................J7 3174-91..................H8 3292B....................F11 5765E...................... H9 7193K-10B........................J16
A2141A8L..................J7 3174-93..................H8 A3292C....................F11 5765F...................... H9 7193L-10A........................J16
2302-31................. A33 3174-9P.................H8 A3400L4.................. F26 A5765F...................... H9 7193T-10...........................J15
LV2302A2................... A27 3174C.................. F23 A3400L6.................. F26 5765M..................... H9 7193U-10..........................J15
LV2302P..................... A27 3175.......................H5 LV3403TR................. A14 C5765N..................... H7 7194-1...............................J13
2411.......................J19 A3175.......................H5 LV3403TRV9............. A14 5765PR................... H7 7194H-3K..........................J13
2434-2....................J19 A3175A....................H5 A3500L4.................. F14 5766E...................... H9 7194HD.............................J13
2434A-2.................J19 3175A.....................H5 A3500N4................. F14 5766F...................... H9 7194M-3K.........................J13
2503-19................. A33 3175B....................H5 A3500P4................. F14 A5767F...................... H9 7194MD............................J13
2503-22................. A33 3175P.....................H8 A3500R6................. F14 5767F...................... H9 A7505AP............................ E10
A2697-20R...............F20 3176..................... F25 A3500T6.................. F14 5767G..................... H9 TA7505AP............................ E10
A2697-20R...............F23 A3176..................... F25 A3500V6................. F14 5767H..................... H9 7505AP............................ E11
2723C....................F15 3179B....................H7 3705RC................... H7 5767M..................... H9 A7506AP............................ E10
A2797-20R...............F20 3180C.................. F24 LV404B23................... A22 C5767N................... H7 TA7506AP............................ E10
A2797-20R...............F23 3181.......................H5 LV404B23V9.............. A22 5768G..................... H9 7506AP............................ E11
A2805C....................J17 3181A.....................H5 LV404B29................... A22 A5768H..................... H9 A7507AP............................ E10
2884D....................F16 3183AC................ F24 LV404B29V9.............. A22 5768H..................... H9 TA7507AP............................ E10
2906A.................... H11 A3184-8R............... F20 LV404B4..................... A21 5768J...................... H9 7507AP............................ E11
Cross Reference by Part Number
A7508AP................................... E10 7576................................H12 A8523.................................... F12 912PS30...........................H8
7508AP....................................E11 7577V................................H7 A8525.................................... F12 912PS36...........................H8
A7509BP................................... E10 7579................................ F20 8542G................................. D17 912PS48...........................H8
TA7509BP................................... E10 7579P.............................. F20 AA8542UA250......................... D17 913JS05A.........................H8
7509BP....................................E11 7579S.............................. F22 AA8542UA265......................... D17 913PS05A.........................H8
A7510BP................................... E10 7583G.............................D13 8543G................................. D11 913PS12G........................H8
TA7510BP................................... E10 7590U............................. F18 8543T.................................. D11 913PS12H.........................H8
7510BP....................................E11 7590U-10........................ F19 8544G................................. D11 913PS12S.........................H8
A7511AP................................... E10 7590U-20........................ F18 8544K................................. D11 948.................................. J19
TA7511AP................................... E10 7591U............................. F18 8544T.................................. D11 948B............................... J19
7511AP....................................E11 7605A-BT....................... J12 8545AK............................... D12 970..................................H10
A7511FP................................... E10 7605AP-15...................... J12 8555D10.6............................ C9 970..................................A32
TA7511FP.................................... E10 7605AP-16...................... J12 8555D11.6............................. C9 970AW............................H10
7511FP.....................................E11 7605APN-8A................... J12 8555DL11.6.......................... C8 970AX.............................A32
7511FP.....................................E11 7605PN-50...................... J12 8555R10.6............................ C9 970AX.............................H10
A7512AP................................... E10 TA7614FP...........................E10 8555R11.6............................. C9 970AXS...........................A32
TA7512AP................................... E10 7647DC........................... F21 8556.................................... B13 970AXS...........................H10
7512AP....................................E11 7647H............................. F21 A8563AG.............................. D19 970HT.............................A32
A7513AP................................... E10 7647HF........................... F21 A8563G................................. D19 970HT.............................H10
TA7513AP................................... E10 7647SA........................... F21 A8564AG.............................. D19 970JR.............................H10
7513AP....................................E11 7647SC........................... F21 A8564G................................. D19 N970P.................................H7
A7513FP................................... E10 A7704LP...........................E13 A8573AG.............................. D19 970S................................A32
TA7513FP................................... E10 7704LP...........................E13 A8573G................................. D19 970S................................H10
7513FP....................................E11 A7704P.............................E13 A8574AG.............................. D19 TSS3169.............................. J18
7513FP....................................E11 7704P..............................E13 A8574G................................. D19
A7514AP................................... E10 A7705P.............................E13 8593AR16.0.......................... C7
7514AP....................................E11 7705P..............................E13 8684G................................. D13
A7514FP................................... E10 A7706P.............................E13 8685G................................. D13
7514FP....................................E11 7706P..............................E13 901-400............................... B17
7514FP....................................E11 A7707L................................E6 901C1................................. B14
A7517AP................................... E10 A7708L................................E6 901C3................................. B15
A7517AP................................... E10 7781AFPN-1................... J12 901C5................................. B15
TA7517AP................................... E10 A7793A ..............................E5 903-400............................... B17
7517AP....................................E11 A7794................................ J14 907FP................................... H8
TA7517FP................................... E10 A7796................................ J14 A9091-18L...............................J4
7517FP....................................E11 A7797A...............................E5 A9091-18LX.............................J4
7517FP....................................E11 A7883FK.......................... G17 A9091-18N...............................J4
A7518AP................................... E10 A7883FK.......................... G18 AA9091RM24.............................J5
TA7518AP.................................... E10 A7884FK.......................... G17 9091RM24.............................J5
7518AP....................................E11 A7884FK.......................... G18 AA9092RM36..............................J5
A7518FP................................... E10 TA7894P...............................E15 9092RM36.............................J5
7518FP....................................E11 7901T................................E8 AA9093RSM48...........................J5
7518FP....................................E11 7901TA..............................E8 9093RSM48...........................J5
7534B..................................... D13 7901TB.............................E8 AA9093TSM48............................J5
7534G..................................... D13 7901TB........................... J13 9093TSM48...........................J5
A7537L4.....................................F12 7901TC.............................E8 AA9094RSM60...........................J5
A7537L4F..................................F12 SS8001G.............................D16 9094RSM60...........................J5
A7537N4....................................F12 SS8001J..............................D16 AA9094TSM60............................J5
A7537N4F . ...............................F12 SS8001L.............................D16 9094TSM60...........................J5
A7537P4 ...................................F12 SS8001U.............................D16 AA9095RSM72...........................J5
A7537P4F .................................F12 SS8002G.............................D16 9095RSM72...........................J5
A7539R6 ...................................F12 SS8002J..............................D16 AA9095TSM72............................J5
A7539R6F..................................F12 SS8002L.............................D16 9095TSM72...........................J5
A7539T6.....................................F12 SS8002U.............................D16 9101C1............................... B14
A7539T6F .................................F12 A8013D............................. F15 9101D11.1........................... B14
A7539V6 ...................................F12 A8013DA........................... F15 9101D11.7........................... B14
A7539V6F .................................F12 A8013DB........................... F15 9101H5............................... B15
A7550P..................................... E14 A8016-93.............................H8 9101H6............................... B15
7550P...................................... E14 A8016-9P............................H8 9101P5................................ B16
A7550PX................................... E14 A8016DBC........................E16 9101P5H............................. B16
7550PX................................... E14 A8016DP...........................E17 9101P6................................ B16
A7551P..................................... E14 A8017DH...........................E18 9101P6H............................. B16
7551P...................................... E14 A8017DLP.........................E18 9101R1............................... B14
A7553A....................................... E8 A8017DP...........................E18 9101R11.1........................... B14
7554LAV................................... E7 A8018DP...........................E19 9101R11.7........................... B14
7554LV...................................... E7 A8020D.............................E18 9101Y5H............................. B15
7554SAV................................... E7 SS8021G..............................D16 9103D10.6............................ B9
7554SV..................................... E7 SS8021J...............................D16 9103D11.6............................. B9
7556R12.0.............................. C11 SS8021L...............................D16 9103T9F.............................. B10
7560-55................................... D18 SS8021U..............................D16 9106CO............................... B11
7560-56................................... D18 SS8022G..............................D16 9107K8A............................. B12
A7571LA..................................... H4 SS8022J...............................D16 912FA20............................... H8
A7571LB..................................... H4 SS8022L...............................D16 912FS12............................... H8
7572-400..................................F27 SS8022P..............................D16 912FS20............................... H8
7572C-14A...............................F19 SS8022U..............................D16 912FS30............................... H8
7572C-15A...............................F19 A8060................................ J19 912FS36............................... H8
7573D......................................F24 A8150................................ J19 912JS12................................ H8
7573DC....................................F24 A8400................................ J19 912JS20................................ H8
7574.........................................F11 A8434G.............................D10 912JS36................................ H8
7574L.......................................F11 A8434N.............................D10 912PA20............................... H8
A7575L2...................................... H4 A8436G.............................D10 912PA36............................... H8
A7575L3...................................... H4 A8436N.............................D10 912PA48............................... H8
A7575L4...................................... H4 G8475RV............................C6 912PS12............................... H8
A7575L5...................................... H4 G8475RW...........................C6 912PS20............................... H8
Limited Warranty and Limitation Of Liability
LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, with respect to its products and parts,
LIMITED 10 YEAR WARRANTY whether used alone or in combination with others. ECII disclaims all
warranties not stated herein.
Engineered Controls International, Inc. (“ECII”) warrants to the original
purchasers the products and repair kits manufactured by it to be free
from defects in materials and workmanship under normal use and
service for a period of 10 years from the date of manufacture. If within LIMITATION OF LIABILITY
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the NOTICE TO USERS OF PRODUCTS
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within The Limited Warranty stated above is a factory warranty to the first
thirty days shall be deemed an absolute and unconditional waiver of purchasers of ECII products. Since most users have purchased
any and all claims of buyer arising out of such defect. these products from ECII distributors, the user must within thirty (30)
days after the user’s discovery of what user believes is a defect,
This warranty does not extend to any product or part that is not notify in writing and return the product to the distributor from whom
installed and used continuously after installation in accordance with he purchased the product/part. The distributor may or may not at
ECII’s printed instructions, all applicable state and local regulations, the distributor’s option choose to submit the product/parts to ECII,
and all applicable national standards, such as those promulgated by pursuant to this Limited Warranty. Failure by buyer to give such
NFPA, DOT and ANSI. This warranty does not extend to any product written notice within thirty (30) days shall be deemed an absolute and
or part that has been damaged by accident, misuse, abuse, failure to unconditional waiver of buyer’s claim for such defects. Acceptance
maintain, or neglect, nor does it extend to any product or part which of any alleged defective product/parts by ECII’s distributor for
has been modified, altered, disassembled, or repaired in the field. replacement or repairs under the terms of ECII’s Limited Warranty in
This warranty does not cover any cosmetic issues, such as scratches, no way determines ECII’s obligations under this Limited Warranty.
dents, marring, fading of colors or discoloration.

Except as expressly set forth above, and subject to the limitation of


liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS Because of a policy of continuous product improvement, ECII
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED reserves the right to change designs, materials or specifications
without notice.
LP-Gas & Anhydrous Ammonia Equipment

Section A
A A

Regulators and Accessories

A1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO® Regulator Color Coding
RegO® domestic first stage, second stage, single stage, and integral twin stage LP-Gas regulators are easy to
identify. In addition to a standard part number marking, each regulator is color coded to indicate the proper application
and to help minimize misapplication in the field that can lead to accidents and costly service callbacks. The color
coding system is standard on all 404, LV404, 2302, LV2302, 2403, 2503, LV4403, and LV5503 series domestic
LP-Gas regulators manufactured after May of 1986.

Brilliant Red - First Stage High Pressure Regulators.


Normally used in two-stage applications in conjunction with a second stage low pressure regulator.

Select Brown - Regulators with Low Pressure delivery range. Select Brown color is found on both:

• Second Stage Low Pressure Regulators.


Normally used in two-stage applications in conjunction with a first stage high pressure regulator.

• Integral Twin Stage Regulators. Designed to provide benefits of two-stage regulation in one compact unit.

Select Blue - Second Stage Regulators for 2 PSIG Systems. Designed to reduce first stage pressure down to 2 PSIG.
Normally used in conjunction with a first stage high pressure regulator.

Classic Gold - Single Stage Regulators. Designed to use alone in Single Stage Systems.

Green - High Pressure Anhydrous Ammonia Regulators.

A Limited Warranty and Limitation of Liability


LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY
LIMITATION OF LIABILITY
LIMITED 10 YEAR WARRANTY

Engineered Controls International, Inc. (“ECII”) warrants to the original


purchasers the products and repair kits manufactured by it to be free NOTICE TO USERS OF PRODUCTS
from defects in materials and workmanship under normal use and service
for a period of 10 years from the date of manufacture. If within thirty days The Limited Warranty stated above is a factory warranty to the first
after buyer’s discovery of what buyer believes is a defect, buyer notifies purchasers of ECII products. Since most users have purchased these
in writing and ships the product to ECII at 100 Rego Drive, Elon, NC 27244, products from ECII distributors, the user must within thirty (30) days after
ECII, at its option, and within forty-five days of receipt , will repair, replace the user’s discovery of what user believes is a defect, notify in writing
F.O.B. point of manufacture, or refund the purchase price of that part and return the product to the distributor from whom he purchased the
or product found by ECII to be defective. Failure of buyer to give such product/part. The distributor may or may not at the distributor’s option
written notice and ship the product within thirty days shall be deemed an choose to submit the product/parts to ECII, pursuant to this Limited
absolute and unconditional waiver of any and all claims of buyer arising Warranty. Failure by buyer to give such written notice within thirty (30)
out of such defect. days shall be deemed an absolute and unconditional waiver of buyer’s
claim for such defects. Acceptance of any alleged defective product/parts
This warranty does not extend to any product or part that is not installed by ECII’s distributor for replacement or repairs under the terms of ECII’s
and used continuously after installation in accordance with ECII’s printed Limited Warranty in no way determines ECII’s obligations under this
instructions, all applicable state and local regulations, and all applicable Limited Warranty.
national standards, such as those promulgated by NFPA, DOT and ANSI.
This warranty does not extend to any product or part that has been
damaged by accident, misuse, abuse, failure to maintain, or neglect, nor
does it extend to any product or part which has been modified, altered, Because of a policy of continuous product improvement, ECII reserves
disassembled, or repaired in the field. This warranty does not cover any the right to change designs, materials or specifications without notice.
cosmetic issues, such as scratches, dents, marring, fading of colors or
discoloration.

Except as expressly set forth above, and subject to the limitation of liability
below, ECII MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, with
respect to its products and parts, whether used alone or in combination
with others. ECII disclaims all warranties not stated herein.

A2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
Warning installation, operation and service.

All ECII ® products are mechanical devices that will


eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber. Filters
The environment and conditions of use will determine the
safe service life of these products. Periodic inspection ECII® LP-Gas equipment is designed to operate in a system
A
and maintenance are essential to avoid serious injury and free from contamination. A variety of in-line filters are
property damage. commercially available to the LP-Gas industry for installation
in domestic systems.
Many ECII® products are manufactured for storage, transport, The use of an in-line filter should be considered when
transfer and use of toxic flammable and dangerous liquids and other system components may be unclean and the system
gases. Such substances should be handled by experienced contaminated by rust, scale, dirt, debris or other foreign
and trained personnel only, using accepted governmental material.
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page Contents Page


Advantages of Two-Stage Regulation......................................... A8 Regulator Outfits......................................................................... A25
Brackets...................................................................................... A33 Second Stage Regulators for 2 PSI Systems.............................. A19
Compact First Stage Regulators................................................. A14 Test Kits....................................................................................... A34
Compact Regulators.................................................................... A26 Twin Stage Automatic Changeover Regulators........................... A23
Compact Twin Stage Regulators................................................. A21 Two PSIG Delivery Pressure Twin-Stage Regulator................... A24
Cross Reference by Part Number..................................................... A36 Two-Stage LP-Gas Systems....................................................... A9
High Pressure Industrial / Commercial lbs.-to-lbs. Regulators........ A28 Vapor Relief Valves..................................................................... A31
High Pressure High Temp Industrial / Commercial lbs.-to-lbs Regulators......... A30 Warnings and Labels................................................................... A35
High Pressure First Stage Regulators......................................... A15
Inlet Fittings................................................................................. A32
Large Capacity Second Stage Regulators.................................. A20
Low Pressure Second Stage Regulators.................................... A16
Low Pressure Single Stage Regulators....................................... A27
Low Pressure Second Stage Tobacco Barn Regulator............... A20
Manifolds..................................................................................... A33
Pigtails......................................................................................... A32
Safety Warning............................................................................ A5
Pipe and Tubing Selection Guide................................................ A10
RegO® Regulator Dependability................................................. A4
RegO® Regulator Designs.......................................................... A13
RegO® Regulator Selection........................................................ A4

A3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO® Regulator Dependability

When RegO® LP-Gas Regulators are properly installed, safe, precise, All give you a product that provides accurate gas delivery under
trouble-free service is the result. varying pressure ranges and load conditions.
Dependability is built into every regulator ... the result of rigid standards RegO® LP-Gas Regulators are UL listed and comply with applicable
of quality control and close tolerance machining. And this has been code requirements.
true for more than 60 years. RegO® Products offer a complete line of LP-Gas Regulators with
RegO® Products are manufactured from the finest materials, and capacities for almost every application.
assembled and tested using procedures second to none.

RegO® Regulator Selection


In order to properly size the RegO® Regulator, find the total load of Stage Regulator, shown below.
the installation. The total load is calculated by adding up the input 5. Find the line on the chart corresponding to the lowest anticipated
ratings (BTU or CFH) of all appliances in the installation. Input ratings winter tank pressure (note that each performance line corresponds
may be obtained from the nameplates on the appliances or from the to and is marked with a different inlet pressure in PSIG).
manufacturers’ literature. 6. Draw a vertical line upward from the point of assumed load
(500,000 BTU’s per hour) to intersect with the line corresponding
Determine the type of regulation needed referring to the chart below.
to the lowest tank pressure.
Type of System Maximum Load Suggested Regulator 7. Read horizontally from the intersection of these lines to the
1,500,000 LV3403TR delivery pressure at the left side of the chart. In this example the
First Stage in a Two delivery pressure will be 9.7 psig. Since the delivery pressure
Stage System LV4403SR Series will be 9.7 psig at the maximum load conditions and lowest
2,500,000
LV4403TR Series anticipated tank pressure, the regulator will be sized properly for
935,000 LV4403B Series the demand.

1,600,000 LV5503B4/B6 LV4403TR Series First Stage Regulator


Second Stage in a
Two Stage System 2,300,000 LV5503B8 Delivery Pressure 150 PSIG Inlet
12 Initial Setting 125 PSIG Inlet
9,800,000 LV6503B Series 11 100 PSIG Inlet
1,000,000 LV4403Y4/Y46R 10
PSIG

Second Stage in a 2
9
PSIG System 2,200,000 LV5503Y6/Y8 8
200,000 LV404B23/29 Series 7
15 PSIG Inlet 50 PSIG Inlet
25 PSIG Inlet
Integral Twin Stage 525,000 LV404B4/B9 Series
A 800,000 LV404Y9 CFH/hr. 100 200 300 400 500 600 700 800 900 1000
BTU/hr. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
Automatic 200,000 7525B23 Series
Changeover 450,000 7525B4 Series Example for a Second Stage Regulator
1. Assume load of 250,000 BTU’s per hour.
* See catalog page for inlet and delivery specifications.
2. Assume a minimum delivery pressure of 10” w.c.
Now determine which regulator in the Series would be most suitable.
Turn to the individual product pages and refer to the Performance 3. Assume a minimum inlet pressure of 10 psig.
Curves. Check the performance of the regulator with your actual load 4. For these conditions, refer to chart for the LV4403B Series,
conditions at the minimum LP-Gas inlet pressure for the regulator. Second Stage Regulator, shown below.
Use the pressure corresponding to your lowest winter temperatures 5. Find the line on the chart corresponding to the anticipated inlet
shown in the chart below or refer to the delivery pressure of your first pressure.
6. Draw a vertical line upward from the point of assumed load
Approx. Approx. Pressure (250,000 BTU’s per hour) to intersect with the line corresponding
Temperature Temperature
Pressure (PSIG) (PSIG) to the lowest inlet pressure.
°F °C Propane Butane °F °C Propane Butane 7. Read horizontally from the intersection of these lines to the
delivery pressure at the left side of the chart. In this example the
-40 -40 3.6 40 4 72 3.0
delivery pressure will read 10.6” w.c. Since the delivery pressure
-30 -34 8 50 10 86 6.9 will be 10.6” w.c. at the maximum load condition and lowest
anticipated inlet pressure, the regulator is sized properly for the
-20 -29 13.5 60 16 102 12
demand.
-10 -23 23.3 70 21 127 17
0 -18 28 80 27 140 23
10 -12 37 90 32 165 29 LV4403B Series Second Stage Regulator
20 -7 47 100 38 196 36
Inches of Water Column

30 -1 58 110 43 220 45 Initial Setting


Delivery Pressure

13
stage regulator. 12
15 PSIG Inlet
Example for a First Stage Regulator 11
10
1. Assume a load of 500,000 BTU’s per hour.
9
2. Assume a minimum delivery pressure of 9.5 psig. 5 PSIG Inlet 8 PSIG Inlet 10 PSIG Inlet
3. Assume a minimum tank pressure of 15 psig. CFH/hr. 0 50 100 150 200 250 300 350 400 450 500
4. For these conditions, refer to chart for the LV4403TR Series, First BTU/hr. 250,000 500,000 750,000 1,000,000 1,250,000

A4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Safety Warnings

Purpose
In its continuing quest for safety, Engineered Controls International, Inc. publishes a series of bulletins explaining
the hazards associated with the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these
factual bulletins will make clear to LP-Gas dealer managers and service personnel, that the utmost care and
attention must be used in the installation, inspection, and maintenance of these products, or problems could
occur which would result in injuries and property damage.
The National Fire Protection Association Pamphlet #58 - 2004 Edition, “Liquified Petroleum Gas Code” states in
Section 1.5 that, “persons who transfer liquid LP-Gas, who are employed to transport LP-Gas, or whose primary
duties fall within the scope of this code shall be trained in proper handling procedures. Refresher training shall
be provided at least every three years. The training shall be documented.” These “ECII® Safety Warnings”
may be useful in training new employees and reminding older employees of hazards that can occur. It is
recommended that all employees be furnished with a copy of NPGA Safety Pamphlet 306, “LP-Gas Regulator
and Valve Inspection and Maintenance.”

Nature of Warnings
It is recognized that warnings should be as brief as possible, but
the factors involved in regulator failures are not simple. They need The Causes of High Pressure Gas in a System are:
to be fully understood so that proper maintenance programs can be
established. If there is a simple warning, it would be: 1. Regulator vents that are clogged or obstructed.
Vents must be clear and fully open at all times.
Inspect regulators regularly as outlined in this safety warning and
Many regulators are equipped with a pressure relief valve which
replace as required per these recommendations. When all of these
discharges to atmosphere through the vent. Ice, snow drifts, dirt,
recommendations are followed, the recommended service life of
bugs, paint, or other foreign material can clog the vents.
an ECII/RegO® regulator (except single stage) manufactured after
1995 is 25 years. The recommended service life of all other ECII/ An obstructed vent may prevent the pressure relief valve from
RegO® regulators is 15 years. operating properly.

LP-Gas Regulators

This bulletin applies most particularly to permanent LP-Gas


installations of cylinders and tanks. The warnings also apply
in most cases to portable installations of recreational vehicles,
A
barbecue grills, etc.
This bulletin is not intended to be an exhaustive treatment of
Large Vent
the subject of regulators and certainly does not cover all
safety practices that should be followed in the installation and
maintenance of LP-Gas systems.

It should not be necessary to remind readers of this bulletin that


regulators must be installed in strict conformance with NFPA
Pamphlets 54 and 58, and all other applicable codes and regulations.
Codes, regulations and manufacturer’s recommendations have been
developed by experts with many years of experience in the LP-Gas
Regulators should be installed with the vent facing down or protected
industry.
so their operation will not be affected by the elements. In cases
Failure to fully follow these codes, regulations and where the regulator vent is equipped with a discharge tube, the outlet
recommendations could result in hazardous installations. of this tube must be facing down. The vents and/or discharge tubes
Pamphlet 58 states “All regulators for outdoor installations, except must be protected from the elements and must be equipped with a
regulators used for portable industrial applications, shall be designed, screen to prevent bugs from obstructing the opening.
installed or protected so their operation will not be affected by
Action Required: Regulators should be properly installed and
the elements (freezing rain, sleet, snow, ice, mud or debris). This
regularly inspected when tanks or cylinders are filled. If vents are
protection may be integral with the regulator.”
clogged or the screen is missing, they must be cleaned or replaced.
If the vent screen is missing and there is evidence of foreign material
Failed and/or Inoperative Regulators
around the vent, the regulator should be replaced.
Failed regulators can cause three kinds of hazards:
2. Foreign material lodging between the regulator nozzle and
• High pressure LP-Gas in a system downstream of the regulator; and
seat disc:
• Leaks of LP-Gas to atmosphere from the regulator itself.
• Loss of pressure due to a “freeze-up” in the orifice. When this occurs, the regulator can remain open, allowing high
pressure gas into the system.
High Pressure LP-Gas in a System
Anything that prevents a regulator from regulating properly could
result in high pressure gas at the regulator outlet and thus in a
system.
High pressure gas into piping and appliances could cause piping
leaks and damage to appliance burner controls with the potential
for fires and explosions.
A5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
This material can come from system piping between the container shut-
off valve and the regulator. Chips created during piping installation or
dirty piping can create this hazard. Corrosion inside of copper pigtails
and piping can cause problems. This can occur particularly when LP-
Gas contains high sulphur or excessive moisture.
Action Required: Make sure regulator inlet piping is clean at the
time of installation. Periodic checks should be made to assure piping
remains clean without corrosion. Never use old pigtails on new LP-Gas
installations. Old pigtails can also work harden and crack if they have
been bent and twisted several times.
3. Wrong regulator installed for the application:
The proper regulator must be used for each system. pressure downstream of the regulator. It could also occur on stationary
For example, installation of high pressure regulators not designed to installations if the regulator is installed below the shut-off valve and the
reduce gas pressure to an appliance requirement of 11” w.c. will cause container is over-filled.
a hazard. Installing a regulator undersized for the load can cause Action Required: Be careful of regulator installation and never overfill
improper combustion at the appliance burner with a potential for carbon any LP-Gas container.
monoxide poisoning.
Action Required: Make sure the regulator is correct for each application Leaks of LP-Gas to Atmosphere
and test the system with a pressure gauge or a manometer. While the occurrences of leaking regulators are rare, they can
and do occur with a potential for fires and explosions.
4. Failure to external mechanical parts due to corrosion:
These leaks can be caused by:
Adjusting springs and relief valve springs can rapidly corrode if exposed
to salt air or industrial pollution. Even moisture condensation on these
springs can cause them to rust and fail.
Failure of these springs will result in failure of the regulator to
control the pressure.
With the vent of a regulator facing down, corrosion products from the
springs could clog the regulator vent screen blocking the vent.
Action Required: Regulator inspection for corrosion should be made
according to the guidelines listed below:
• For underground installations subject to submersion, the regulator
should be inspected every time the container is filled.
• For known corrosive atmospheres of salt air or chemical pollution,
the regulator should be inspected at least once a year.
A
1. Corrosion of the relief valve spring or foreign material on the seat
disc which causes the relief valve to open, will cause LP-Gas to
escape through the regulator vent, as well as permitting high pressure
into the system.
Action Required: Regulator inspection for corrosion should be made
according to the guidelines listed below:
• For underground installations subject to submersion, the regulator
should be inspected every time the container is filled.
• For known corrosive atmospheres of salt air or chemical pollution,
Corroded the regulator should be inspected at least once a year.
Spring • For other applications, the regulator should be inspected every 3
years.
• For other applications, the regulator should be inspected every 3 A casual inspection for corrosion can be made by examining the
years.
surface and looking into the bonnet after the bonnet cap has been
A casual inspection for corrosion can be made by examining the
removed. This sometimes will alert the inspector to corrosive
surface and looking into the bonnet after the bonnet cap has been
conditions. Certainly the regulator should be examined in more detail
removed. This sometimes will alert the inspector to corrosive
by a qualified and trained technitian. For single stage, second stage
conditions. Certainly the regulator should be examined in more detail
and twin stage regulators remove the bonnet cap and examine the
by a qualified and trained technitian. For single stage, second stage
inside of the bonnet with a strong flashlight. For first stage regulators
and twin stage regulators remove the bonnet cap and examine the
that have a bonnet cap, shut down the system, remove the bonnet
inside of the bonnet with a strong flashlight. For first stage regulators
cap and spring and examine the inside of the bonnet with a strong
that have a bonnet cap, shut down the system, remove the bonnet
flashlight. After the inspection, the regulator must be adjusted to the
cap and spring and examine the inside of the bonnet with a strong
proper pressure.
flashlight. After the inspection, the regulator must be adjusted to the
If any corrosion is evident, replace the regulator.
proper pressure.
If any corrosion is evident, replace the regulator. 2. Bad piping connections at the regulator inlet and outlet. This can
occur at the time of installation where connections are loose or the
It is essential that the regulator bonnet cap be tightly in place at
regulator may have been overstressed by excessive wrenching. It
all times to prevent the entrance of water, bugs, dirt, etc. Foreign
is important that proper wrenches, both on the piping and on the
material can cause the regulator to function improperly with potentially
regulator inlet and outlet, be used when connecting the system piping,
hazardous results.
and that the regulator die cast body is not cracked by wrenching the
5. Liquid propane in the regulator: pipe too deeply into the body.
This can occur on recreational vehicles, unless the regulator is Action Required: Always test for leaks at time of installation and
installed substantially higher than the container shut-off valve. Here, inspect for leaks if there is reason to believe that pipe connections
sloshing propane could get into the regulator with the resulting high could cause a hazard.

A6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Loss of Pressure Underground Installations
Freeze-up inside the regulator. Special hazards can occur if regulators are not properly installed in
underground systems. Water, dirt, mud and insects can get into the
regulator if the bonnet cap is not tightly in place and the vent is not
protected with a proper vent tube, opening above any potential water
level.
Most problems occur because the waterproof dome on the buried
storage tank does not extend above the ground level sufficiently to
keep out water and mud.
Ice Refer to NPGA No. 401.

Regulator adjustment closure


cap must be tight.
End of regulator vent tube
Grade ground downward and located at top inside of
away around housing dome. housing dome cover.
This prevents water collecting
and running into or standing 2 to 6 inches
around dome. minimum.

This will prevent the regulator from regulating properly.


Regulator freeze-ups occur because there is excessive moisture
in the gas. Freeze-ups can also occur in pigtails that are kinked or
bent where free flow of the LP-Gas is restricted. These freeze-ups 6 inches minimum
can occur when the moisture, gas flow and temperature combine to (24 inches minimum if
create a hazardous condition. Freeze-ups can occur at temperatures subject to vehicular traffic).
above 32º F.
Action Required: All LP-Gas should be checked for moisture content
prior to delivery to consumers and proper amounts of anhydrous
methanol added if the gas cannot be returned to the supplier. Any Note: Water mark left in housing dome at level
container suspected of having excessive moisture should be treated above regulator vent, or end of vent tube requires
with the proper amount of methanol. replacement of regulator. Then correct installation.

Customer Safety General Warning A


Since regulators are often used by consumers without previous
knowledge of the hazards of LP-Gas, and the LP-Gas dealers are the All ECII® Products are mechanical devices that will eventually
only ones who have direct contact with the consumers, become inoperative due to wear, contaminants, corrosion
and aging of components made of materials such as metal
It is the dealer’s responsibility to make sure that his and rubber. As a general recommendation,Regulators should
customers are properly instructed in safety matters relating be replaced in accordance with all of the recommendations
to their installation. outlined in this safety warning. The recommended service life
of a regulator is one of many factors that must be considered
At the very minimum, it is desirable that these customers: in determining when to replace a regulator.
1. Know the odor of LP-Gas and what to do in case they smell
gas. Use the NPGA “Scratch ’n Sniff” leaflet. The environment and conditions of use will determine the safe service
2. Are instructed to never tamper with the system. life of these products. Periodic inspection and maintenance are
3. Know that when protective hoods are used to enclose essential.
regulators and/or valves, that these hoods must be closed, Because ECII® Products have a long and proven record of quality
but not locked. and service, LP-Gas dealers may forget the hazards that can occur
4. Keep snow drifts from covering regulators. because a regulator is used beyond its safe service life. Life of a
5. Know the location of the cylinder or tank shut-off valve in regulator is determined by the environment in which it “lives.” The LP-
emergencies. Gas dealer knows better than anyone what this environment is.
NOTE: There is a developing trend in state legislation and in proposed
national legislation to make the owners of products responsible for
replacing products before they reach the end of their safe useful life.
LP-Gas dealers should be aware of legislation which could affect
them.

A7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Advantages of Two-Stage Regulation

First Stage Regulator


with Relief Valve and
Second Stage
Pressure Tap
Regulator
with Large Vent and
Pressure Tap
To Appliances/Furnace

First Stage Piping

body. This chilling action is more severe in single-stage systems as


The regulator is truly the heart of an LP-Gas installation. It must gas expands from tank pressure to 11” w.c. through a single regulator
compensate for variations in tank pressure from as low as 8 psig nozzle.
to 220 psig – and still deliver a steady flow of LP-Gas at 11” w.c. Two-stage systems can greatly reduce the possibility of freeze-ups
to consuming appliances. The regulator must deliver this pressure and resulting service calls as the expansion of gas from tank pressure
to 11” w.c. is divided into two steps, with less chilling effect at each
despite a variable load from intermittent use of the appliances. regulator. In addition, after the gas exits the first-stage regulator and
Though a single-stage system may perform adequately in many enters the first-stage transmission line, it picks up heat from the line,
installations, the use of a two-stage system offers the ultimate in pin- further reducing the possibility of second-stage freeze-up.

A point regulation. Two-stage regulation can result in a more profitable


LP-Gas operation for the dealer resulting from less maintenance and
Service calls for pilot outages and electronic ignition system failures
are also reduced as a result of more uniform appliance pressure from
fewer installation callbacks – and there is no better time than now for two-stage systems.
installing RegO® Regulators in two-stage systems.
Economy of Installation
Uniform Appliance Pressure In a single-stage system, transmission line piping between the
The installation of a two-stage system – one high pressure regulator container and the appliances must be large enough to accommodate
at the container to compensate for varied inlet pressures, and one the required volume of gas at 11” w.c. In contrast, the line between the
low pressure regulator at the building to supply a constant delivery first and second stage regulators in two-stage systems can be much
pressure to the appliances – helps ensure maximum efficiency and smaller as it delivers gas at 10 psig to the second-stage regulator.
trouble-free operation year-round. It is important to note that while Often the savings in piping cost will pay for the second regulator.
pressure at the appliances can vary up to 4” w.c. using single- As an additional benefit, single-stage systems can be easily converted
stage systems, two-stage systems keep pressure variations within to two-stage systems using existing supply lines when they prove
1” w.c. New high-efficiency appliances require this closer pressure inadequate to meet added loads. This is the least expensive and best
control for proper ignition and stable, efficient operation. In fact, one method of correcting the problem.
major manufacturer requires the use of two-stage systems with their
appliances. Allowance for Future Appliances
A high degree of flexibility is offered in new installations of two-
Reduced Freeze-ups/Service Calls
stage systems. Appliances can be added later to the present load
Regulator freeze-up occurs when moisture in the gas condenses and – provided the high pressure regulator can handle the increase – by
freezes on cold surfaces of the regulator nozzle. The nozzle becomes the addition of a second low pressure regulator. Since appliances
chilled when high pressure gas expands across it into the regulator can be regulated independently, demands from other parts of the
installation will not affect their individual performances.

Size The System Correctly


Replace Pigtails
Prior to installing your two-stage system, be sure the system pipe If you are replacing an old regulator, remember to replace the
and tubing is properly sized. Proper sizing will help ensure constant copper pigtail. The old pigtail may contain corrosion which can
delivery pressure to the appliances during fluctuating loads at all restrict flow. In addition, corrosion may flake off and wedge
times. Just as important, be sure the RegO® Regulators you choose between the regulator orifice and seat disc – preventing proper
are capable of handling the desired load. This is another advantage lock-up.
of two-stage systems – they are capable of handling much
more BTU’s/hr. than single-stage systems. The RegO® “LP-Gas
Serviceman’s Manual” provides complete information on pipe sizing
and proper regulator selection.

A8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Two-Stage LP-Gas Systems ...
Require First Stage Regulators with Built-in Relief Valves

First Stage Regulator


with Relief Valve and
Pressure Tap Second Stage
Regulator
with Large Vent
and Pressure Tap
To Appliances/Furnace

First Stage Piping

Ambient Ground Pressure at Which


With no first stage relief valve, Temperature Tank Pressure Temperature liquid will form
propane liquid may form here. . .
70° F. 120 PSIG 40° F. 72 PSIG

Resulting in sudden pressure surge due to flashing into vapor here! 80° F. 140 PSIG 50° F. 86 PSIG
First stage relief can prevent liquid from forming in first stage piping 90° F. 165 PSIG 60° F. 102 PSIG
during periods with no gas demand! ! !

Pressure at which liquid can form


at various temperatures.

Vapor Pressures of LP Gases A


250

200
Pressure PSIG

150
Propane

100

50
Butane

-40 -20 0 20 40 60 80 100 120


Temperature °F.

The Problem
Many modern LP-Gas appliances are equipped with pilotless ignition stage regulator will not relieve the pressure in first stage piping.
systems. Water heaters and older appliances use pilot lights, but it The rapid vaporization of the liquid may cause a rapid pressure surge
has become a common practice for energy conscious homeowners to that could seriously damage critical components of the appliance and
shut-off the pilot when leaving home for extended periods of time. In furnace controls.
each instance, there is no gas demand at all for extended periods.
A fire or explosion could occur as a consequence.
The Consequences
If the first stage regulator fails to lock-up tight, usually as a result The Solution
of a worn seat disc or foreign material lodged between nozzle and RegO® LV4403 Series First Stage Regulators with Built-In Relief
seat disc, pressure will build-up in the first stage piping – possibly Valves reduce the possibility of this serious hazard in two stage
to a level that approaches tank pressure. Combining this with warm applications. The built-in relief valve is designed to vent as needed
ambient temperatures and cool ground, propane liquid may form in and reduce the possibility of first stage piping pressure from becoming
the first stage piping. high enough to form liquid.
When gas demand resumes, this liquid may pass through the second
stage regulator into the appliances and furnace. NOTE – the second
A9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pipe and Tubing Selection Guide
Use the following simple method to assure the selection of the correct sizes of piping and tubing for LP-Gas vapor systems. Piping between first and second stage
regulators is considered, as well as low pressure (inches water column) piping between second stage, single stage, or integral twin stage regulators and appliances.

Instructions:
1. Determine the total gas demand for the system by adding up the BTU/hr input
from the appliance nameplates and adding demand as appropriate for future
appliances.
2. For second stage or integral twin stage piping:
A. Measure length of piping required from outlet of regulator to the appliance
furthest away. No other length is necessary to do the sizing.
B. Make a simple sketch of the piping, as shown.
C. Determine the capacity to be handled by each section of piping. For
example, the capacity of the line between a and b must handle the total
demand of appliances A, B, and C; the capacity of the line from c to d must
handle only appliance B, etc.
D. Using Table 3 select proper size of tubing or pipe for each section of piping,
using values in BTU/hr for the length determined from step #2-A. If exact
length is not on chart, use next longer length. Do not use any other length
for this purpose! Simply select the size that shows at least as much capacity
as needed for each piping section.
3. For piping between first and second stage regulators
A. For a simple system with only one second stage regulator, merely measure
length of piping required between outlet of first stage regulator and inlet of
second stage regulator. Select piping or tubing required from Table 1.
B. For systems with multiple second stage regulators, measure length of piping
required to reach the second stage regulator that is furthest away. Make a
simple sketch, and size each leg of piping using Table 1, 2, or 3 using values
shown in column corresponding to the length as measured above, same as
when handling second stage piping.

Example 1 Example 2.
Determine the sizes of piping or tubing required for the twin-stage LP-Gas Determine the sizes of piping or tubing required for the two-stage LP-Gas
installation shown. installation shown.

Total piping length = 84 feet (use Table 3 @90 feet) 58 Feet


First Stage 26
From a to b, demand = 38,000 + 35,000 + 30,000 Regulator Feet
= 103,000 BTU/hr; use 3/4” pipe Range
aa Furnace 65,000
From b to c, demand = 38,000 + 35,000
200,000
= 73,000 BTU/hr; use 1/2” pipe or 3/4” tubing f h
From c to d, demand = 35,000 BTU/hr; use 1/2” pipe or 5/8” tubing a b c d
From c to e, demand = 38,000 BTU/hr; use 1/2” pipe or 5/8” tubing a g
From b to f, demand = 30,000 BTU/hr; use 1/2” pipe or 1/2” tubing e

Second Stage Water Clothes


Regulator Heater Dryer
38,000 35,000
84 Feet
Room Total first stage piping length = 26 feet; first stage regulator setting is
Heater 10psig (use Table 1 or 2 @ 30 feet)
30,000 From aa to a, demand = 338,000 BTU/hr; use 1/2” pipe, 1/2” tubing, or 1/2” T
a plastic pipe.
f Total second stage piping length = 58 feet (use Table 3 @ 60 feet)
b c From a to b, demand = 338,000 BTU/hr; use 1” pipe
e From b to c, demand = 138,000 BTU/hr; use 3/4” pipe or 7/8” tubing
d
From c to d, demand = 100,000 BTU/hr; use 1/2” pipe or 3/4” tubing
Clothes From d to e, demand = 35,000 BTU/hr; use 1/2” pipe or 1/2” tubing
Water
Heater Dryer From b to f, demand = 200,000 BTU/hr; use 3/4” pipe or 7/8” tubing
38,000 35,000 From c to g, demand = 38,000 BTU/hr; use 1/2” pipe or 1/2” tubing
From d to h, demand = 65,000 BTU/hr; use 1/2” pipe or 5/8” tubing

A10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pipe and Tubing Selection Guide
Example 3
Determine the sizes of piping or tubing required for the 2 PSI LP-Gas installation shown.
Total first stage piping length = 26 feet; first stage regulator setting is 10psig (use Table 1 or 2 @ 30 feet)
Total 2 PSI Piping Length = 19 ft. (use Table 4 @ 20 ft. or Table 6 @ 20 ft.)
From aa to a, demand= 338,000 BTU
use 3/8” CSST or 1/2” copper tubing or 1/2” pipe
From Regulator a to each appliance:
From a to b, demand= 65,000 BTU; length = 25 ft. (Table 5),
use 1/2” CSST
From a to c, demand= 200,000 BTU; length = 30 ft. (Table 5)
use 3/4” CSST
From a to d, demand= 38,000 BTU; length = 21 ft.* (Table 5)
use 3/8” CSST *use 25 ft. column Furnace
Range
From a to e, demand= 35,000 BTU; length = 40 ft. (Table 5)
65,000 200,000
use 1/2” CSST First Stage c
26 30
Regulator 19 Water
Feet b Feet
Feet Heater
25 21
Feet 38,000
a Feet
d
aa 12

2 PSI Second Inches 40


Line Pressure Feet
Stage Regulator
Regulator
Clothes
Dryer
35,000 e

Table 1 – First Stage Pipe Sizing (Between First and Second Stage Regulators) 10 PSIG Inlet with a 1 PSIG Pressure Drop Maximum capacity of pipe or tubing, in thousands of BTU/hr or LP-Gas

Size of Pipe or Length of Pipe or Tubing, Feet


Copper Tubing,
Inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400
A
3/8” 558 383 309 265 235 213 196 182 171 161 142 130 118 111 104 90 89 89 82 76
1/2” 1387 870 700 599 531 481 443 412 386 365 323 293 269 251 235 222 211 201 185 172
5/8” 2360 1622 1303 1115 988 896 824 767 719 679 601 546 502 467 438 414 393 375 345 321
Copper 3/4”
Tubing 3993 2475 2205 1887 1672 1515 1394 1297 1217 1149 1018 923 843 790 740 700 664 634 584 543
1/2” 3339 2295 1843 1577 1398 1267 1165 1084 1017 961 852 772 710 660 619 585 556 530 488 454
(O.D.)
3/4” 6982 4799 3854 3298 2923 2649 2437 2267 2127 2009 1780 1613 1484 1381 1296 1224 1162 1109 1020 949
Pipe 1” 13153 9040 7259 6231 5507 4989 4590 4270 4007 3785 3354 3039 2796 2601 2441 2305 2190 2089 1922 1788
Size
11/4” 27004 18560 14904 12756 11306 10244 9424 8767 8226 7770 6887 6240 5741 5340 5011 4733 4495 4289 3945 3670
11/2” 40461 27809 22331 19113 16939 15348 14120 13136 12325 11642 10318 9349 8601 8002 7508 7092 6735 6426 5911 5499
2” 77924 53556 43008 36809 32623 29559 27194 25299 23737 22422 19871 18005 16564 15410 14459 13658 12971 12375 11385 10591
* Total length of piping from outlet of first stage regulator to inlet of second state regulator (or to inlet of second stage regulator furthest away).
Notes: 1) To allow 2 PSIG pressure drop, multiply total gas demand by .707, and use capacities from table. 2) For different first stage pressures, multiply total gas demand by the following
factors, and use capacities from table. Ex: 1,000,000 BTU load at 5 PSI: 1,000,000 (1.12) = 1,200,000 BTU then use chart bases on 1,200,000 BTU
First Stage Pressure PSIG Multiply By
20 .844 Data Calculated per NFPA #54 & 58
15 .912
5 1.120

Table 2 – First Stage Plastic Tubing Sizing 10 PSIG Inlet with a 1 PSIG Pressure Drop Maximum capacity of plastic tubing in thousands of BTU/hr of LP-Gas

Size of Plastic Tubing Length of Tubing, Feet*


NPS SDR 10 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400
½T 7.00 1387 954 766 655 581 526 484 450 423 399 354 321 295 274 257 243 231 220 203 189
½ 9.33 3901 2681 2153 1843 1633 1480 1361 1267 1188 1122 995 901 829 772 724 684 649 620 570 530
¾ 11.00 7811 5369 4311 3690 3270 2963 2726 2536 2379 2248 1992 1805 1660 1545 1499 1369 1300 1241 1141 1062
1T 11.50 9510 6536 5249 4492 3981 3607 3319 3088 2897 2736 2425 2197 2022 1881 1765 1667 1583 1510 1389 1293
1T 12.50 10002 6874 5520 4725 4187 3794 3490 3247 3046 2878 2551 2311 2126 1978 1856 1753 1665 1588 1461 1359
1 11.00 14094 9687 7779 6658 5901 5346 4919 4578 4293 4055 3594 3257 2996 2787 2615 2470 2346 2238 2059 1916
1¼ 10.00 24416 16781 13476 11534 10222 9262 8521 7927 7438 7026 6226 5642 5190 4829 4531 4280 4064 3878 3567 3318
2 11.00 66251 45534 36566 31295 27737 25131 23120 21509 20181 19063 16895 15308 14084 13102 12293 11612 11028 10521 9680 9005
* Total length of piping from outlet of first stage regulator to inlet of second state regulator or to inlet of second stage regulator furthest away.
First Stage Pressure PSIG Multiply By
20 .844
15 .912 Data Calculated per NFPA #54 & 58
5 1.120
A11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pipe and Tubing Selection Guide
Table 3 – Second Stage or Integral Twin Stage Pipe Sizing 11 Inches Water Column Inlet with a 1/2 Inch Water Column Drop Maximum capacity of pipe or tubing in thousands of BTU/hr of LP-Gas

Size of Pipe Length of Pipe or Tubing, Feet


or Copper
Tubing, Inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400
3/8” 49 34 27 23 20 19 - - - - - - - - - - - - - -
1/2” 110 76 61 52 46 42 38 36 33 32 - - - - - - - - - -
5/8” 205 151 114 97 86 78 71 67 62 59 - - - - - - - - - -
Copper 3/4” 348 239 192 164 146 132 120 113 105 100 - - - - - - - - - -
Tubing 7/8” 536 368 296 253 224 203 185 174 161 154 - - - - - - - - - -
(O.D.) 1/2” 291 200 161 137 122 110 102 94 87 84 74 67 62 58 54 51 48 46 43 40
3/4” 608 418 336 287 255 231 212 198 185 175 155 141 129 120 113 107 101 97 89 83
Pipe
Size 1” 1146 788 632 541 480 435 400 372 349 330 292 265 244 227 213 201 191 182 167 156
11/4” 2353 1617 1299 1111 985 892 821 764 717 677 600 544 500 465 437 412 392 347 344 320
11/2” 3525 2423 1946 1665 1476 1337 1230 1144 1074 1014 899 815 749 697 654 618 587 560 515 479
2” 6789 4666 3747 3207 2842 2575 2369 2204 2068 1954 1731 1569 1443 1343 1260 1190 1130 1078 992 923
* Total length of piping from outlet of regulator to appliance furthest away. Data Calculated per NFPA #54 & 58

Table 4-Maximum Capacity of CSST In Thousands of BTU per hour of undiluted LP-Gases Pressure of 2 psi and a pressure drop of 1 psi (Based on a 1.52 Specific Gravity Gas)*

Length of Pipe or Tubing, Feet


EHD** Flow
Size Designation 10 20 30 40 50 75 80 110 150 200 250 300 400 500
3/8”
13 426 262 238 203 181 147 140 124 101 86 77 69 60 53
15 558 347 316 271 243 196 189 169 137 118 105 96 82 72
1/2”
18 927 591 540 469 420 344 333 298 245 213 191 173 151 135
19 1106 701 640 554 496 406 393 350 287 248 222 203 175 158
3/4”
23 1735 1120 1027 896 806 663 643 578 477 415 373 343 298 268
25 2168 1384 1266 1100 986 809 768 703 575 501 448 411 355 319
30 4097 2560 2331 2012 1794 1457 1410 1256 1021 880 785 716 616 550
1”
31 4720 2954 2692 2323 2072 1685 1629 1454 1182 1019 910 829 716 638
Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 1/2 psi (based on 13 in. water column outlet pressure), DO NOT USE THIS TABLE. Consult with regulator manufacturer for pressure drops and capacity factors. Pressure drops across a
regulator may vary with flow rate.
CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Consult with regulator or tubing manufacturer for guidance.
*Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger number of bends and/or fittings shall be increased by an equivalent length of tubing according to the following equation: L-1.3n where L is additional length (ft) of tubing and n is the number of
additional fittings and/or bends.

A
**EHD –– Equivalent Hydraulic Diameter –– A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing.

Table 5-Maximum Capacity of CSST In Thousands of BTU per hour of undiluted LP-Gases Pressure of 11 Inch Water Column and a Pressure Drop of 0.5 Inch Water Column (Based on a 1.52 Specific Gravity Gas)*

Length of Pipe or Tubing, Feet


EHD** Flow
Size Designation 5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300
3/8”
13 72 50 39 34 30 28 23 20 19 17 15 15 14 11 9 8 8
15 99 69 55 49 42 39 33 30 26 25 23 22 20 15 14 12 11
1/2”
18 181 129 104 91 82 74 64 58 53 49 45 44 41 31 28 25 23
19 211 150 121 106 94 87 74 66 60 57 52 50 47 36 33 30 26
3/4”
23 355 254 208 183 164 151 131 118 107 99 94 90 85 66 60 53 50
25 426 303 248 216 192 177 153 137 126 117 109 102 98 75 69 61 57
30 744 521 422 365 325 297 256 227 207 191 178 169 159 123 112 99 90
1”
31 863 605 490 425 379 344 297 265 241 222 208 197 186 143 129 117 107
*Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger number of bends and/or fittings shall be increased by an equivalent length of tubing according to the following equation: L = 1.3n where L is additional length (ft) of tubing and n is the number of
additional fittings and/or bends. **EHD –– Equivalent Hydraulic Diameter –– A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing.

Table 6 – Copper Tube Sizing or Schedule 40 Pipe Sizing* In Thousands of BTU per hour of undiluted LP-Gases 2 PSIG inlet with a 1PSIG pressure drop (Between 2 PSIG service regulator & line pressure regulator).

Size of Pipe or Length of Pipe or Tubing, Feet


Copper Tubing,
Inches 10 20 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700
3/8” 451 310 249 213 189 171 157 146 137 130 104 89 79 72 66 61 58 54 49 45
1/2” 1020 701 563 482 427 387 356 331 311 294 236 202 179 162 149 139 130 123 111 102
5/8” 1900 1306 1049 898 795 721 663 617 579 547 439 376 333 302 278 258 242 229 207 191
Copper 3/4”
Tubing 3215 2210 1774 1519 1346 1219 1122 1044 979 925 743 636 563 511 470 437 410 387 351 323
1/2” 2687 1847 1483 1269 1125 1019 938 872 819 773 621 531 471 427 393 365 343 324 293 270
(O.D.)
3/4” 5619 3862 3101 2654 2352 2131 1961 1824 1712 1617 1298 1111 985 892 821 764 717 677 613 564
Pipe 1” 10585 7275 5842 5000 4431 4015 3694 3436 3224 3046 2446 2093 1855 1681 1546 1439 1350 1275 1155 1063
Size
11/4” 21731 14936 11994 10265 9098 8243 7584 7055 6620 6253 5021 4298 3809 3451 3175 2954 2771 2618 2372 2182
11/2” 32560 22378 17971 15381 13632 12351 11363 10571 9918 9369 7524 6439 5707 5171 4757 4426 4152 3922 3554 3270
2” 62708 43099 34610 29621 26253 23787 21884 20359 19102 18043 14490 12401 10991 9959 9162 8523 7997 7554 6844 6297

A12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO® Regulator Designs
Typical of the LV4403 Low Pressure Regulators and
LV4403 High Pressure Regulators. Molded Diaphragm Assembly
RegO® LP-Gas Regulators have been designed to Twin layers of molded synthetic rubber sandwich a
tough, flexible fabric to give super sensitive response
give outstanding performance and dependability with a in a temperature range of -40º to +165ºF. Molded
minimum of maintenance. diaphragm seals in a groove between the body and
Nozzle Orifice bonnet.
Replaceable and precision machined to prevent scoring of the
seat disc. Diaphragm Plate
Rigid diaphragm plate transmits pressure variations to
Seat Disc control linkage.
Replaceable, resilient construction gives sure closing at lock up
pressure. Straight line seat disc to nozzle operation provides Relief Valve
even seat disc wear and positive lock up. It is built in and tamper resistant. Large bonnet vent
allows high capacity relief on second stage regulators.
Pivot Pin
Fully enclosed in regulator body. Bonnet Cap
Bonnet cap incorporates travel stop to help control
Control Linkage downstream pressure in the unlikely event of a
Provides quick response to diaphragm movement; moves directly regulator malfunction.
perpendicular to nozzle orifice to meter gas flow, give positive
closure and reduce seat disc wear. Large Bonnet Vent
Large vent is equipped with protective screen and
Built-In Pressure Tap threaded for 3⁄4” F. NPT vent piping. Large vent helps
Provides a convenient way to check downstream pressure on prevent ice from building up and blocking the vent
both high and low pressure models. during inclement weather. The regulator should be
Body & Bonnet installed with vent down and the vent protected
Painted, heavy-duty zinc resists corrosion and gives long-life against blockage.
protection, even under “salty air” conditions.

Typical of the 1580 Industrial High


Pressure Regulators
The pounds-to-pounds, industrial regulator gives higher delivery
pressure as tank pressure decreases, thus permitting full use of the
gas in the tank. Most units are field adjustable to meet changing
Adjusting Assembly
conditions. Large handle with lock-nut
release allows easy resetting
of delivery pressure.

A
Connections
Machined and threaded into the body casting; also
includes 1⁄4” NPT pressure gauge ports.

Seat Disc
Synthetic rubber assembly attached directly to the
yoke assembly to ensure proper movement and
regulation.

Back Cap Spring


Provides added upward force to help provide a
positive lock-up.

Integral O-Ring
Minimizes tendency to
vibrate or hum under
extreme loads.
Sensitivity
In those cases where there is a choice of delivery pressure ranges,
the lowest spring range which will fulfill your requirements is
recommended because the sensitivity of a regulator decreases as the
Relief Valves
range of the adjusting spring increases.
Most high pressure regulators are not equipped with integral relief
valves. For certain applications where it is desirable to protect
equipment downstream of the regulator, relief valves must be installed
in the line.

A13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Compact First Stage Regulators
LV3403TR

Application Materials
Ideal for use as a first stage regulator on any domestic size ASME or Body............................................................................................... Zinc
DOT container in propane gas installations requiring up to 1,500,000 Bonnet............................................................................................ Zinc
BTU’s per hour. The regulator is factory set to reduce container Spring............................................................................................ Steel
pressure to an intermediatepressure of approximately 10 PSIG. Seat Disc.....................................................................Resilient Rubber
Diaphragm.............................. Integrated Fabric and Synthetic Rubber

Features
• Compact design can be connected to a service valve using either
a POL adapter or a RegO product pigtail.

• Large threaded 3/8” FNPT bonnet vent caneasily be piped-away UL


®
underground installations without the need of glue kits or extra
adapters.

• Non Adjustable

• Large flow orifice resists freeze ups due to water concentration in


LPG vapor.

• Design provides for good flow regulation at both high and low
container pressures.

• Built in relief valve and travel stop comply with NFPA 58 over
pressure requirements.

• Incorporates 1/8” FNPT downstream pressure tap for an easy


inline check of the regulator’s delivery pressure.

• Molded diaphragm provides an o-ring type seal between the body


and bonnet.
A 12

• Body and bonnet are assembled in the USA using the unique,
patented RegUlok seal system.
Initial Setting
• Fully painted in brilliant red for complete corrosion protection. 11

• Mounting bracket available as an accessory: part number 2302-31. 150 PSIG INLET
DELIVERY PRESSURE PSIG

100 PSIG INLET


10

50 PSIG INLET

9
25 PSIG INLET

3.865” CFH/hr.
BTU/hr.
100
250,000
200
500,000
300
750,000
400
1,000,000
500
1,250,000
600
1,500,000
750
1,750,000
FLOW PROPANE

PRODU

10
O
G

CT
RE

S
10

Y
NT

3.56” E
Y

AR A
WA R R
Ordering Information
Factory
Delivery Vapor Capacity BTU/hr
Part Number Inlet Connection Outlet Connection Orifice Size Pressure Bonnet Vent Position Propane*
LV3403TR Over Outlet
¼” [Link] ½” [Link] ¼” 10 PSIG 1,500,000
LV3403TRV9 9:00
* Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the regulator setting and delivery pressure 20% lower than the setting.

A14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
High Pressure First Stage Regulators
LV4403SR and TR Series

Application Materials
Provides accurate first stage regulation in two-stage bulk tank Body ............................................................................... Die Cast Zinc
systems. Reduce tank pressure to an intermediate pressure of 5 to 10 Bonnet ............................................................................ Die Cast Zinc
PSIG. Also used to supply high pressure burners for applications like Nozzle Orifice ............................................................................. Brass
industrial furnaces or boilers. Also incorporated in multiple cylinder Spring .......................................................................................... Steel
installations. Valve Seat Disc ......................................................... Resilient Rubber
Diaphragm ............................ Integrated Fabric and Synthetic Rubber
Features
• Incorporate integral relief valves for added system protection.
LV4403 Series
• Large vent helps prevent blockage and has 3⁄4” [Link] thread for
vent piping. UL
®

• Bonnet vent positioned over outlet to avoid icing and contamination


by foreign material.

• Unique bonnet vent profile designed to minimize vent freeze over


when properly installed.

• Replaceable valve orifice and valve seat disc.

• Straight-line valve closure reduces wear on seat disc.

• Large molded diaphragm is extra sensitive to pressure changes.

• Built in pressure tap has plugged 1⁄8” [Link] outlet.

• Plug can be removed with a 3⁄16” hex allen wrench. 21⁄4"

• Extra long lever arm provides uniform delivery pressure.

• Brilliant red finish. A


71⁄8"

LV4403SR
150 PSIG Inlet 41⁄2"
Initial Setting 125 PSIG Inlet 51⁄4"
Delivery Pr essure

7 100 PSIG Inle


t
6
PSIG

5
4
50 PSIG Inlet
3
10 PSIG Inlet 25 PSIG Inle
t

CFH/hr. 100 200 300 400 500 600 700 800 900 1000
BTU/hr. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
37⁄8" 11⁄2"
LV4403TR
150 PSIG Inlet
12 Initial Setting 125 PSIG Inlet
PRODU
Delivery Pr essure

11

10
100 PSIG Inlet O
10
G

CT
PSIG

RE

9
S

8
10

7
15 PSIG Inlet 50 PSIG Inlet
NT

25 PSIG Inlet E
Y

AR A
WA R R
CFH/hr. 100 200 300 400 500 600 700 800 900 1000
BTU/hr. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
Ordering Information
Outlet Orifice Factory Delivery Adjustment Range* Integral Relief Vapor Capacity BTU/hr
Part Number Inlet Connection Connection Size Pressure (PSIG) Included Propane**
LV4403SR4 5 1-5
½” F. NPT
LV4403TR4 10 5-10
½” F. NPT
LV4403SR9 5 1-5
¼” Yes 2,500,000
LV4403TR9 10 5-10
F. POL
LV4403SR96 5 1-5
¾” [Link]
LV4403TR96 10 5-10
* When used for final stage pressure control, must either incorporate integral relief valve or separate relief valve should be specified in accordance
with NFPA Pamphlet 58.
** Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting.

A15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Low Pressure Second Stage Regulators
LV4403B Series

Application Materials
Designed to reduce first stage pressure of 5 to 20 PSIG down to Body ............................................................................... Die Cast Zinc
burner pressure, normally 11” w.c. Ideal for medium commercial Bonnet ............................................................................ Die Cast Zinc
installations, multiple cylinder installations and normal domestic Nozzle Orifice ............................................................................. Brass
loads. Spring .......................................................................................... Steel
Valve Seat Disc ......................................................... Resilient Rubber
Diaphragm ............................ Integrated Fabric and Synthetic Rubber
Features
• Large vent helps prevent blockage and has 3⁄4" [Link] for vent
piping.
LV4403B Series
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 2 PSIG with the seat disc removed.

• Incorporates integral relief valves.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure reduces wear on seat disc.

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.

• Large molded diaphragm is extra sensitive to pressure changes.

• Built in pressure tap has plugged 1⁄8" [Link] outlet. Plug can be
removed with a 3⁄16" hex allen wrench.

• Select brown finish. UL


®

Backmount Design
A Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.
11⁄2" 33⁄16"

41⁄2" Outlet

71⁄8"
51⁄4"
Dia.

75⁄32"
21⁄4" PRODU

10
Approx. O
G

CT
RE

17⁄16" 313⁄16"
LV4403B
10

Y
NT

E
Y

LV4403BR AR A
WA R R

Ordering Information
Outlet Orifice Factory Delivery Bonnet Vent Vapor Capacity BTU/
Part Number Inlet Connection Connection Size Pressure Adjustment Range Position hr. Propane**
LV4403B4 1½”
LV4403B46 ½” F. NPT
LV4403B46R* 11” w.c. at 10 PSIG
#28 Drill 9” to 13” w.c. Over Inlet 935,000
¾” F. NPT Inlet
LV4403B66
¾” F. NPT
LV4403B66R*
* Backmount design
** Maximum flow based on 10 PSIG inlet and 9” w.c. delivery pressure.

A16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Low Pressure Second Stage Regulators
LV4403B66RA Series

Application Materials
Designed to reduce first stage pressure of 5 to 20 PSIG down to Body ...................................................................... Die Cast Aluminum
burner pressure, normally 11” w.c. Ideal for medium commercial Bonnet ............................................................................ Die Cast Zinc
installations, vapor meter installations and normal domestic loads. Nozzle Orifice ............................................................................. Brass
Spring .......................................................................................... Steel
Valve Seat Disc ......................................................... Resilient Rubber
Features Diaphragm ............................ Integrated Fabric and Synthetic Rubber
• 90 degree right angle inlet to outer connection for meter or
standard installations.

• Large vent helps to prevent blockage and has ¾” F. NPT for vent
piping.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 2 PSIG with the seat disc removed.

• Replaceable valve orifice and valve seat.

• Straight line valve closure reduces wear on seat disc

• Unique bonnet vent prifile minimizes vent freeze over when


properly installed. Attached to Vapor Meter
• Large molded diaphragm is extra sensitive to pressure changes.

• Built in pressure tap has plugged ⅛” F. NPT outlet. Plug can be


removed with a 3/16” hex allen wrench.

• Select Brown Finish


UL
Right Angle Design
®

A
Can mount directly to vapor meter. It is also suitable for mounting w/ Mounting Bracket
directly to the house piping. It will retrofit into existing installations that
are currently using a 90 degree, right angle regulator.

51⁄4"
71⁄4"

PRODU

10
O
G

CT
RE

90°
S
10

Y
NT

2 3/16" E
Y

AR A
WA R R

Ordering Information
Outlet Orifice Factory Delivery Adjustment Bonnet Vent Vapor Capacity BTU/
Part Number Inlet Connection Connection Size Pressure Range Position hr. Propane*
LV4403B66RA
11” w.c. at 10
¾” F. NPT ¾” F. NPT 3/16” 9” to 13” w.c. Over Inlet 1,000,000
LV4403B66RAB** PSIG Inlet

* Maximum flow is based on 10 PSIG inlet and 9” w.c. delivery pressure.**


** Mounting Bracket Included.

A17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Low Pressure Second Stage Regulators
LV5503B Series

Application Materials
Designed to reduce first stage pressure of 5 to 20 PSIG down to Body (LV5503B Series ......................................... Die Cast Aluminum
burner pressure,normally 11” w.c. Ideal for larger commercial and Bonnet (LV5503B Series) ..................................... Die Cast Aluminum
industrial applications, multiple cylinder installations and large Nozzle Orifice ............................................................................ Brass
domestic systems. Spring ......................................................................................... Steel
Valve Seat Disc ........................................................ Resilient Rubber
Diaphragm ........................... Integrated Fabric and Synthetic Rubber
Features
• Incorporates integral relief valve.

• With 15 PSIG inlet pressure, regulator is designed to not LV5503B Series


pass more than 2 PSIG with the seat disc removed.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure saves wear on seat disc and


orifice.

• Built in pressure tap has plugged 1⁄8” [Link] outlet. Plug


can be removed with a 3⁄16” hex allen wrench.

• Large bonnet vent profile minimizes vent freeze over when


properly installed.

• Extra long lever arm for uniform delivery pressure.


UL
• Large diaphragm is extra sensitive to pressure changes. ®

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R
Ordering Information
Factory
Inlet Outlet Delivery Adjustment Vapor Capacity BTU/hr.
Part Number Connection Connection Orifice Size Pressure Range Bonnet Vent Position Propane
LV5503B4 ½” F. NPT
¾” F. NPT ¼” 11” w.c. at 10 1,600,000
LV5503B6 9” - 13” w.c. Over Inlet
¾” F. NPT PSIG Inlet
LV5503B8 1” F. NPT 9/32 ” 2,300,000
Maximum flow is based on 10 PSIG inlet and 9” w.c. delivery pressure.

A18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Second Stage Regulators for 2 PSI Systems
LV4403Y and LV5503Y Series

Application Materials
Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG. Body (LV4403Y Series).................................................. Die Cast Zinc
A line pressure regulator is required downstream to reduce the 2 Body (LV5503Y Series ......................................... Die Cast Aluminum
PSIG to a nominal 11” W.C. Bonnet (LV4403Y Series)............................................... Die Cast Zinc
Bonnet (LV5503Y Series) ..................................... Die Cast Aluminum
Nozzle Orifice ............................................................................ Brass
Features Spring ......................................................................................... Steel
Valve Seat Disc ........................................................ Resilient Rubber
• Large vent helps prevent blockage and has ¾” [Link] for vent piping. Diaphragm ........................... Integrated Fabric and Synthetic Rubber
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 5 PSIG with the seat disc removed.

• Incorporates an integral relief valve.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure reduces wear on seat disc.

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.

• Large molded diaphragm is extra sensitive to pressure changes.

• Built in pressure tap has plugged 1⁄8” [Link] outlet. Plug


can be removed with a 3⁄16” hex allen wrench.

• Select blue finish.


UL
*Backmount Design
®
LV5503Y Series
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install. LV4403Y Series A
LV4403Y4, LV4403Y46R

LV5503Y8
2.20
Initial Setting
2.00
15 PSIG Inlet
1.80
5 PSIG Inlet 10 PSIG Inlet
1.60
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
5,000,000 1,250,000 2,000,000

LV5503Y6
2.20
Initial Setting
2.00

1.80
15 PSIG Inlet PRODU

10
O
5 PSIG Inlet
G

CT

1.60 10 PSIG Inlet


RE

0 100 200 300 400 500 600 700 800 900 1000 1100 1200
500,000 1,250,000 2,000,000
10

Y
NT

E
Y

AR A
WA R R
Ordering Information
Bonnet Vent Vapor Capacity BTU/hr.
Part Number Inlet Connection Outlet Connection Orifice Size Adjustment Range
Position Propane***

LV4403Y4 1/2” F. NPT 1/2” F. NPT 1/4” 2 PSIG @ 10 PSIG Inlet Over Inlet 1,000,000
LV4403Y46R* 1/2” F. NPT 3/4” F. NPT 1/4” 2 PSIG @ 10 PSIG Inlet Over Inlet 1,000,000
LV5503Y6 3/4” F. NPT 3/4” F. NPT 1/4” 2 PSIG @ 10 PSIG Inlet Over Inlet 2,200,000
LV5503Y8 3/4” F. NPT 1” F. NPT 9/32” 2 PSIG @ 10 PSIG Inlet Over Inlet 2,200,000
Maximum flow is based on 10 PSIG inlet pressure and 1.5 PSIG delivery pressure.

A19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Low Pressure Second Stage Tobacco Barn Regulator
LV5503G4 Series
Application Materials
Especially developed for drying barns in the tobacco industry. The
LV5503G4 regulator will supply a steady and constant flow of fuel to as Body...................................................................... Die Cast Aluminum
many as 12 to 20 burners throughout the barn. Bonnet................................................................... Die Cast Aluminum
Nozzle Orifice ............................................................................ Brass
Spring ......................................................................................... Steel
Features Valve Seat Disc ........................................................ Resilient Rubber
Diaphragm ........................... Integrated Fabric and Synthetic Rubber
• Similar to construction of the LV5503B Series. Provides the
same stability, low lock-up, and sensitive performance.
LV5503G4 Series
• Equipped with integral relief valve.

• Built in pressure tap has plugged 1/8” [Link] outlet. Plug


can be removed with a 3/16” hex allen wrench.
PRODU
• Distinctive yellow finish.
10
O

CT
RE

S
10

Y
NT
E

Y
AR A
WA R R

UL ®

Ordering Information
Inlet Outlet Orifice Adjustment Bonnet Vent Vapor Capacity BTU/

A
Part Number Connection Connection Size Factory Delivery Pressure Range Position hr. Propane*
LV5503G4 ½” F. NPT ¾” F. NPT ¼” 15” w.c. at 15 PSIG Inlet 8” - 18” w.c. Above Inlet 1,750,000
Maximum flow is based on 15 PSIG inlet pressure and 13” w.c. delivery pressure.

* Maximum flow is based on 15 PSIG inlet and 12” w.c. delivery pressure.
Large Capacity Second Stage Regulators
LV6503B Series
Application
These regulators are designed to reduce gas pressure from the first
stage regulator down to appliance pressure, normally 11” w.c. They
are for use in LP-Gas applications.

Features
• Tee style inlet and outlet connections – made from ductile iron.
• Incorporate integral large 2” [Link] relief vents.
• Built in pressure taps for both inlet and outlet pressure.

• Full capacity relief at 10 psig inlet will keep the down stream
pressure at less than 2 PSIG per NFPA 58.

PRODU Materials
10
O

UL
G

CT
RE

®
Inlet Body............................................................................ Ductile Iron
10

Y
NT

E
Body............................................................................ Cast Aluminum
Y

AR A
WA R R
Ordering Information Bonnet ........................................................................ Cast Aluminum
Inlet Outlet Factory Delivery Adjustment Bonnet Vent Vapor Capacity BTU/hr.
Part Number Connection Connection Orifice Size Pressure Range Position Propane
LV6503B14 1½” F. NPT 1½” F. NPT 8,000,000
11” w.c. at 10 PSIG
⅝” 8½” - 14” w.c. Over Inlet
LV6503B16 2” F. NPT 2” F. NPT Inlet 9,750,000
* Maximum flow is based on 10 PSIG inlet and 20% droop.

A20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Compact Twin Stage Regulators
LV404B4 and LV404B9 Series

Application Materials
This compact two-stage regulator is designed to reduce container Body (First Stage)...................................................................... Brass
pressure down to 11” w.c. delivery pressure. It is ideal for “on-site” Body (Second Stage) .................................................... Die Cast Zinc
cylinder applications, mobile homes and average domestic service Nozzle Orifice ............................................................................ Brass
including small ASME and 100 to 420 pound DOT cylinders. Spring ......................................................................................... Steel
Valve Seat Disc ........................................................ Resilient Rubber
Diaphragm ........................... Integrated Fabric and Synthetic Rubber
Features
• Incorporates integral relief valves.

• With 15 PSIG inlet pressure, regulator is designed to not pass more


UL
®

LV404B4 LV404B4V9 LV404B9


than 2 PSIG with the seat disc removed.

• Large vent helps prevent blockage and has 3⁄4” F. NPT for vent
piping.

• Compact size allows for easy installation — especially under


container hoods and within collars.

• Relief vent on the first stage is consistently in the down position.

• Built in pressure taps on both first and second stage regulators have
plugged 1⁄8” [Link] outlets. Plugs can be removed with a 3⁄16”
hex allen wrench.

• Select brown finish.

PRODU

10
O
G

CT
RE

S
10

Y
NT
E
Y

AR A
WA R R

Ordering Information
Bonnet Bonnet Accessories
Factory Adjustment Vent Vent Capacity
Inlet Outlet Orifice Delivery Range 2nd Position Position BTU/hr. 1st Stage Vent
Part Number Connection Connection Size Pressure Stage 1st Stage 2nd Stage Propane* Pipe-Away
LV404B4 Down Over Outlet
½” F. NPT
LV404B4V9 9 o’clock 9 o’clock
¼” F. NPT
LV404B46 Down Over Outlet
¾” F. NPT
LV404B46V9 11” w.c. at 100 9 o’clock 9 o’clock
.219 9” - 13” w.c. 525,000 404PE
LV404B9 PSIG Inlet Down Over Outlet
½” F. NPT
LV404B9V9 9 o’clock 9 o’clock
F. POL
LV404B96 Down Over Outlet
¾” F. NPT
LV404B96V9 9 o’clock 9 o’clock
Maximum flow is based on 25 PSIG inlet pressure and 9” w.c. delivery pressure.

A21
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Compact Twin Stage Regulators
LV404B23 and LV404B29 Series

Application Materials
The LV404B23 and LV404B29 Series Regulators are designed for Body (First Stage).......................................................... Die Cast Zinc
small domestic applications with flow requirements up to 200,000 Body (Second Stage) .................................................... Die Cast Zinc
BTU’s/hr. These regulators are ideal for mobile homes, cottages and Bonnet LV404B23, First Stage ...................................... Die Cast Zinc
“on-site” cylinder applications. These regulators can also be used in Bonnet LV404B29, First Stage .................................................. Brass
RV applications if a protective Bonnet, Second Stage .................................................. Die Cast Zinc
cover is also supplied. Diaphragms ......................... Integrated Fabric and Synthetic Rubber
Springs ....................................................................................... Steel
Valve Seat Discs ...................................................... Resilient Rubber
Features
• Provides all the benefits of two-stage regulation in one compact unit
(for small size loads) at a reasonable cost. LV404B23 LV404B23V9 LV404B29
• Incorporates integral relief valve in second stage.

• With 15 PSIG inlet pressure, regulator is designed to not pass more


than 2 PSIG with the seat disc removed.

• Full size vents on the first and second stage are both tapped 1⁄8”
[Link].

• Built in pressure taps on both first and second stage regulators have
plugged 1⁄8” [Link] outlet. Plugs can be removed with a 3⁄16” hex
allen wrench.

• Compact size allows for easy installation – especially under


UL®

container hoods and within collars.

• May be used with a variety of pigtails, inlet adapters and manifolds.


POL type pigtails can be used in LV404B29 Series.

A • Select brown finish.

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R
Ordering Information
Accessories
Bonnet
Factory Adjustment Vent Bonnet Vent Capacity 1st Stage
Part Inlet Outlet Orifice Delivery Range 2nd Position 1st Position BTU/hr Vent 2nd Stage
Number Connection Connection Size Pressure Stage Stage 2nd Stage Propane* Pipe-Away Vinyl Cover Bracket
LV404B23 ¼” F. NPT
11” w.c. at Rear Over Outlet
LV404B29 F. POL
½” F. NPT .100 100 PSIG 9-13” w.c. 200,000 404PE 2302-55 2302-31
LV404B23V9 ¼” F. NPT Inlet Left 9 o’clock
LV404B29V9 F. POL
* Maximum flow based on 25 PSIG inlet pressure and 9” w.c. delivery pressure.

A22
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Twin Stage Automatic Changeover Regulators
7525B Series

Application Materials
These combination automatic changeover, two stage regulators are Body (First Stage).......................................................... Die Cast Zinc
especially suitable for homes, mobile homes, cottages, construction Body (Second Stage) .................................................... Die Cast Zinc
and other portable two cylinder installations. Empty containers may Bonnet First Stage . ....................................................... Die Cast Zinc
be replaced without interrupting customer’s gas service. Bonnet, Second Stage .................................................. Die Cast Zinc
First Stage Nozzle Orrifice ........................................................ Brass
Springs ....................................................................................... Steel
Features Valve Seat Discs ...................................................... Resilient Rubber
Diaphragms ......................... Integrated Fabric and Synthetic Rubber
• Automatic changeover switches from “service” to “reserve” cylinder
automatically without interrupting service.

• The Second Stage Incorporates wide bonnet drip lip vent to guard
against freeze-up when properly installed.
UL ®

• With 15 PSIG inlet pressure the second stage, regulator is designed 7525B23
to not pass more than 2 PSIG with the seat disc removed.
7525B4
• Allows “reserve” cylinder to supplement the flow of gas from the
“service” cylinder during extreme load or severe cold conditions.

• Incorporates molded diaphragm in second stage regulators.

• Integral indicator gauge.

• Change over knob and indicator are integral to the first stage.

• Select brown finish on first stage.

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
Ordering Information WA R R

Automatic Changeover Capacity BTU/hr.


Kit Number Inlet Outlet Pigtails Included-2 Bracket Included
Regulator Included Propane
5726B23 7525B23 912FA20
2302-31 200,000
5727B23 7525B23 912FS20
1/4” Inverted 1/2” F. NPT
5754B4 7525B4 Flare 912FA20
2503-22 450,000
5755B4 7525B4 912FS20
Maximum flow is based on 25 PSIG inlet pressure and 9” w.c. delivery pressure.

A23
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Two PSIG Delivery Pressure Twin-Stage Regulator
LV404Y9

Application
SPECIAL 2 PSIG DELIVERY pressure twin stage regulator is
designed to reduce container pressure down to 2 PSIG. A line
pressure regulator is required downstream to reduce the 2 PSIG to a
nominal 11” W.C.
UL
®

Features
• Incorporates integral relief valve in the 2 PSIG stage portion of the
regulator.

• Designed to pass not more than 5 PSIG with the seat disc
removed.

• Large vent helps prevent blockage and has a ¾” [Link] for vent
piping.

• Compact size for easy installation.

• Built in pressure taps for both the 10 PSIG regulator and 2 PSIG
regulator, Plugs can be removed with a 3/16” hex Allen wrench.
LV404Y9
• Select Blue Finish to designate 2 PSIG delivery pressure for 2-
pound systems.

Materials
Body (First Stage).......................................................... Die Cast Zinc
Body (2 PSIG Stage) ..................................................... Die Cast Zinc
A Bonnet First Stage . ................................................................... Brass
Bonnet, Second Stage .................................................. Die Cast Zinc
Diaphragms ......................... Integrated Fabric and Synthetic Rubber
Springs ....................................................... Steel and Stainless Steel
Valve Discs ............................................................... Resilient Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Factory
Bonnet Vent
Inlet Outlet Delivery Adjustment 2 PSIG Bonnet Capacity
Part Number Orifice Size Position 1st
Connection Connection Pressure Range (PSIG) Vent Position BTU/HR*
Stage
(PSIG)

LV404Y9 [Link]
½” [Link] .219 2 1.8 to 2.5 Down Outlet 800,000
(CGA 510)
Maximum flow is based on 25 PSIG inlet pressure and 1.5 PSIG delivery pressure.

A24
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Two Stage Regulator Outfits 5807, 5808, 5820 Series
Application LV4403TR9
LV4403B Series
These outfits contain the equipment required to provide two-
stage regulation.
UL
®

Features PRODU

10
O

CT
• Includes a new pigtail. This helps ensure that a new pigtail is

RE

S
installed along with the regulator.

10

Y
NT
E

Y
AR A
WA R R

• Features, designs, and performance characteristics of the


individual components may be found under the appropriate
section of this catalog.
Ordering Information
1st Stage Regulator Included 2nd Stage Regulator Included 913PS12
Capacity
Kit Inlet x Outlet Inlet x Outlet Bracket Pigtail BTU/hr.
Number Part Number Female Part Number F. NPT Included Included Propane

5807 LV4403B4 ½” x ½” 2503-22 2503-22


LV4403TR9 POL x ½” NPT
5808 LV4403B46R ½” x ¾”
Not 913PS12 935,000
Required
5820 LV4403TR96 POL x ¾” NPT LV4403B66R ¾” x ¾”

Twin Stage Regulator Outfits 5828 and 5832


Application LV404B4 LV404B23V9
This outfit contains the equipment required to provide twin-stage regulation.
UL
®

Features
• Includes a new pigtail. This helps ensure that a new pigtail is installed along
with the regulator.
PRODU

10
O

A
G

CT
RE

• Features, designs, and performance characteristics of the individual components


S
10

may be found under the appropriate section of this catalog.


NT

E
Y

AR A
WA R R

Ordering Information
2503-22
Twin Stage Pigtails Capacity BTU / hr.
Kit Number Regulator Included Inlet F. NPT Outlet F. NPT Included Propane
912JS12
5828 LV404B4 525,000
¼” ½” 912JS12
5832 LV404B23V9 200,000

Automatic Changeover Regulator Outfits 5726B23, 5727B23, 5754B4, 5755B4


Application 7525B4
This outfit contains the equipment required to provide twin-stage
UL ®

regulation.
7525B23
Features PROD U

10
O
G

CT
RE

• Includes a new pigtail. This helps ensure that a new pigtail is


10

Y
NT

E
Y

AR A

installed along with the regulator. WA R R

• Features, designs, and performance characteristics of the individual


components may be found under the appropriate section of this
catalog. 912FA20
Ordering Information
Automatic
Capacity BTU/hr.
Kit Number Changeover Inlet Outlet Pigtails Included-2 Bracket Included
Propane
Regulator Included
5726B23 7525B23 912FA20
2302-31 200,000
5727B23 7525B23 912FS20
1/4” Inverted Flare 1/2” F. NPT
5754B4 7525B4 912FA20
2503-22 450,000
5755B4 7525B4 912FS20
A25
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Compact Regulators
302 Series
Application
These compact regulators are designed for smaller outdoor grills
and fish cookers. It is intended for use on small portable appliances
that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe
systems per NFPA 58, 1995 edition.

Features
• All metal, die cast construction.

• Molded diaphragms assure close control of burner pressure.

• Durable valve levers.

• Variety of model configurations and sizes available.

• All POL inlet connections are soft nose.


302 UL
®

Materials
Body............................................................................... Die Cast Zinc
Bonnet ........................................................................... Die Cast Zinc
Springs ....................................................................................... Steel
Valve Seat Discs ...................................................... Resilient Rubber
Diaphragms ................................................ Molded Synthetic Rubber

302V
PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Factory Vapor Capacity
Part Outlet Orifice Adjustment Bonnet Vent
Type Inlet Connection Delivery BTU/hr.
Number Connection Size Range Position
Pressure Propane*
302 ¼” F. NPT Small Vent Above
302S Soft M. POL w/60 DMS orifice Inlet
11” w.c. at
302V Single 3/8” F. No. 50 Drip Lip Above
¼” F. NPT 100 PSIG 9-13” w.c. 125,000
Stage NPT Drill Inlet
inlet
302V9 ¼” F. NPT Drip Lip at 9
302V9LS Soft POL w/o orifice o’clock
Maximum flow is based on 25 PSIG inlet pressure and 9” w.c. delivery pressure.

A26
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Low Pressure Single Stage Regulators
LV2302 Series

Application
A compact, sturdy regulator incorporating many of the quality features
found in larger domestic regulators. Ideal for outdoor LP-Gas grills.
The regulator reduces cylinder pressure down to burner pressure, UL
normally 11” w.c. It is intended for use on small portable appliances ®

that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe
systems per NFPA 58, 1995 edition.

Features
• Compact size with large capacity rating.

• Equipped with integral relief valve.

• Unique bonnet vent profile minimizes vent freeze over when properly
installed.

• Built in pressure tap has plugged 1⁄8” [Link] outlet.

• Large diaphragm provides better regulation and lower lock-up.

• Classic gold finish.

A
Materials
Body............................................................................... Die Cast Zinc
Bonnet ........................................................................... Die Cast Zinc
Springs ....................................................................................... Steel
Valve Seat Discs ...................................................... Resilient Rubber
Diaphragms ......................... Integrated Fabric and Synthetic Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R
Ordering Information
Part Inlet Outlet Factory Delivery Adjustment Bonnet Vent Vapor Capacity BTU/hr.
Orifice Size
Number Connection Connection Pressure Range Position Propane*
LV2302A2 ¼” F. NPT 11” w.c. at 100
3/8” F. NPT No. 49 Drill 9”-13” w.c. Over Outlet 150,000
LV2302P M. POL PSIG Inlet
Maximum flow is based on 10 PSIG inlet pressure and 9” w.c. delivery pressure.

A27
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
High Pressure Industrial / Commercial Pounds-to-Pounds Regulators
597F Series

Application
Designed to reduce propane gas container pressure down to
between 3 and 100 PSIG. Ideal for liquid or vapor service, they
can be used in a variety of applications including salamander
heaters, weed burning torches, fish cookers, tar pot heaters, and
other industrial type services.

Features
• Provides high capacity performance at a reasonable price.

• Suitable for both liquid and vapor service.

• Compact design provides for easy installation.

• Negative direct acting design helps to keep regulator delivery


pressures constant even as tank pressures drop.

• Negative direct acting design provides for excellent performance


when needed most – in cold weather, when tank pressures are
lowest and system demands are highest.
UL
®

• Consistent delivery pressure, especially in cold weather, helps


assure maximum performance from the second stage regulator.

• Can be readily fitted with a pressure gauge in the 1/4” [Link] port.
Materials

• Molded diaphragm provides an o-ring like seal between the body Body............................................................................................. Zinc
and the bonnet. Bonnet ......................................................................................... Zinc
Springs ....................................................................................... Steel
• Fully painted in brilliant red for complete corrosion protection. Valve Seat Discs ...................................................... Resilient Rubber
A Diaphragms ......................... Integrated Fabric and Synthetic Rubber
• Available in four adjustable ranges for maximum performance. Adjusting Screw.......................................................................... Brass

• Bonnet and body are assembled in the USA using the unique,
patented RegULokSM Seal System.

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Adjustment Outlet Recommended Delivery Capacity Determined at Capacity BTU/hr.
Inlet Connection
Number Method Connection Pressure Range (PSIG) Set Pressure of PSIG* Propane**
597FA 1-15 10 1,750,000
597FB 10-30 20 3,000,000
Tee Handle 1/4” NPT 1/4” NPT
597FC 20-45 30 3,500,000
597FD 40-100 40 4,500,000
* Set pressure established at 100 PSIG inlet and a flow of 250,000 BTU/hr.
** Capacity determined at actual delivery pressure 20% less than set pressure with inlet pressure 20 PSIG higher than the set pressure.

A28
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
High Pressure Industrial / Commercial Pounds-to-Pounds Regulators
1580M Series and AA1580M Series

Application
UL
®
Designed to reduce LP-Gas and anhydrous ammonia container
pressures to between 3 and 125 PSIG. Precision-built with a multi-
million BTU capacity, the 1580M series is perfect for such big, tough
jobs as crop dryers, asphalt batch mixing plants, road building “tar
wagons”, heat treating and other large industrial and commercial
loads. It’s also ideal as a first stage regulator in large multiple
operations. The AA1580M series is ideal for use in anhydrous
ammonia applications such as blue print machines and heat treating.

Features
• Large nozzle and straight through flow provides high capacity and
resistance to freeze-up.

• O-ring on retainer assembly provides a dampening effect to reduce


vibration.

• Suitable for both liquid and vapor service.

• Can be readily fitted with pressure gauge in 1⁄4” F. NPT port.

Materials
PRODU

10
O
Body........................................................................ Forged Aluminum
G

CT
RE

Bonnet .................................................................. Die Cast Aluminum


S
10

Spring ......................................................................................... Steel


NT

E
Y

AR A
WA R R
Valve Seat Discs ...................................................... Resilient Rubber
Diaphragms ......................... Integrated Fabric and Synthetic Rubber
Ordering Information
Recommended Capacity
A
Delivery Determined at
Part Adjustment Inlet & Outlet Pressure Range B Height Set Pressure of
Number Service Method Connections (PSIG) A Width (max.) PSIG Capacity**
AA1582MW Tee Handle
3-25 20 2,100 CFH NH3
AA1582MK Hex Head ¼”
NH3 2 3
16 ” 4⅛”
AA1582ML F. NPT 20-50 30 2,400 CFH NH3
AA1582MH 45-125 60 2,600 CFH NH3
7,000,000
3-30 20
1584MN BTU/hr. LPG
7,500,000
LP-Gas 25-50 30
1584ML BTU/hr. LPG
½” 8,000,000
45-125 2 15
16 ” 4⅞” 60
1584MH F. NPT BTU/hr. LPG
AA1584MW 3-25 20 4,500 CFH NH3
AA1584ML NH3 20-50 30 4,800 CFH NH3
AA1584MH 45-125 60 5,100 CFH NH3
11,000,000
3-30 20
1586MN BTU/hr. LPG
Tee Handle
12,000,000
LP-Gas 25-50 30
1586ML BTU/hr. LPG
¾” 14,000,000
F. NPT 45-125 60
1586MH BTU/hr. LPG
AA1586MW 3-25 20 7,000 CFH NH3
AA1586ML NH3 20-50 3 ½” 7” 30 7,700 CFH NH3
AA1586MH 45-125 60 8,900 CFH NH3
11,000,000
3-30 20
1588MN BTU/hr. LPG
1” 12,000,000
LP-Gas 25-50 30
1588ML F. NPT BTU/hr. LPG
14,000,000
45-125 60
1588MH BTU/hr. LPG
* Set pressure is established with 100 PSIG inlet pressure and a flow of 500,000 BTU/hr. propane for 1580M Series, 90 CFH/hr. NH3 for
AA1582M Series and 180 CFH/hr. NH3 for AA1584M and AA1586M Series.

** Capacities determined at actual delivery pressure 20% less than set pressure with inlet pressure 20 PSIG higher than set pressure.

NOTE: Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. Use of a relief valve
upstream or downstream of these regulators is recommended in accordance with NFPA 58.

A29
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
High Pressure / High Temperature Industrial / Commercial Pounds-to-
Pounds Regulators X1584M, X1586M Series

Application
Designed to reduce LP-Gas container pressures to between 3 and
50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing UL
®

and other large industrial and commercial load application utilizing


high temperature LP-Gas or high temperature atmosphere under
A conditions up to 300ºF. Also ideal as a first stage regulator in large
multiple operations.

Features
• Special diaphragm and seat materials are suitable for up to 300ºF.
temperatures.

• Large nozzle and straight through flow provides high capacity and
resistance to freeze ups.

• Suitable for both liquid and vapor service.

• Can be fitted with high pressure gauge in 1⁄4” F. NPT port.


Engineered Controls International, Inc. recommends that these
gauges use silver braze rather than soft solder construction.
Materials
Body........................................................................ Forged Aluminum
PRODU
Bonnet .................................................................. Die Cast Aluminum

10
O
G

CT

Spring .......................................................................... Stainless Steel


RE

Diaphragms ......................... Integrated Fabric and Synthetic Rubber


10

Seat Discs .......................... High Temperature Resilient Composition


NT

E
Y

AR A
Backup Seal ....................... High Temperature Resilient Composition WA R R

Ordering Information
Inlet & Outlet Recommended Delivery Capacity Determined at Capacity BTU/hr.
Part Number Service Adjustment Method
Connections Pressure Range (PSIG) Set Pressure of PSIG* Propane**
X1584MN 3-30 20 7,000,000
½” F. NPT
X1584ML 25-50 30 7,500,000
X1586MN 3-30 20 11,000,000
LP-Gas Tee Handle ¾” F. NPT
X1586ML 25-50 30 12,000,000
X1588MN 3-30 20 11,000,000
1” F. NPT
X1588ML0 25-50 30 12,000,000
* Set pressure is established with 100 PSIG inlet pressure and a flow of 500,000 BTU/hr. propane.
** Capacities determined at actual delivery pressure 20% less than set pressure with inlet pressure 20 PSIG higher than set pressure.
NOTE: Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. Use of a relief valve upstream or downstream of these regulators is
recommended in accordance with NFPA 58.

A30
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Vapor Relief Valves
3139 Series

Application
Designed for use as a relief valve on first stage regulators that comply
with the NFPA 58 [Link] exception: “first stage regulators with a
rated capacity of more than 500,000 BTU/hr. shall be permitted to
have a seperate relief valve.

Features
• Pop-action design keeps product loss to a minimum. UL
®

• Suitable for use downstream of 1580 series regulators on vapor


systems to comply with NFPA 58.

• May be installed with on either the regulator pressure gauge port or


on a fitting downstream from the regulator outlet.

• Constructed of non-corosive brass.

PRODU

10
G O

CT
RE

S
10

Y
E NT
Y

AR A
WA R R
3139-18 3139-26 3139-39

Flow Capacity
at 120% of Set
Part Number Set Pressure Regulator Settings Connection Size Height Width
Pressure
(SCFH Propane)
3139-18 18 PSIG 10 PSIG 1357*
3139-26 26 PSIG 15 PSIG ¼” M. NPT 2 27/32” 1 1/16” 1725**
3139-38 38-PSIG 20 PSIG 2304***
* Flow recorded at 21.6 PSI inlet pressure for this valve.
** Flow recorded at 31.2 PSI inlet pressure for this valve.
*** Flow recorded at 45.6 PSI inlet pressure for this valve.

A31
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Copper Pigtails
912 and 913 Series
Straight Pigtails Ordering Information Application
Part Number
¼” Tube ⅜” Tube Pigtails are available in a variety of connections, sizes and styles.
Care should always be taken in selecting the proper pigtail for a
Approximate ⅞” Hex 1⅛” Hex ⅞” Hex
particular application.
Connections Length Short Nipple Long Nipple Short Nipple
5” - ½” 913JS05 Note: Engineered Controls International, Inc. recommends a new
12” 912PS12 - 913PS12
pigtail be installed with every new and replaced regulator.
[Link] x 20” 912PS20 912PA20 913PS20
[Link] 30”
36”
912PS30
912PS36
-
912PA36
913PS30
913PS36
Features
48” 912PS48 912PA48 913PS48 • Heavy duty construction.
12” 912FS12 - - • Individually soldered connections to the copper tubing.
¼” Inverted 20” 912FS20 912FA20 - • Each pigtail is individually tested prior to shipment.
Flare x [Link] 30” 912FS30 - -
36” 912FS36 - -
5” - - 913JS05 Materials
¼” [Link] x 12” 912JS12 - - Tubing...................................................................................... Copper
[Link] 20” 912JS20 - - Connection ................................................................................ Brass
36” 912JS36 - - 913PS12
½” [Link] x UL
12” - - 913LS12
[Link]
®

½” [Link] x Bent Pigtails Ordering Information


12” - - 913KL12
⅜” [Link]
Part Number
⅜” Tube
Approximate Type/Degree of
PRODU
Connections Length ⅞” Hex Short Nipple Bend

10
O
¼” M. NPT x
G

CT

913JS05A
RE

M. POL 5” 90°
10

913PS05A
NT

E
Y

AR A
WA R R
M. POL x 913PS12G 270° Right Hand
913JS05A 913PS12G 913PS05A M. POL 12” 913PS12H 270° Left Hand
A 913PS12S 360°

Inlet Fittings
These inlet fittings are available for assembly into either first stage
of single stage regulators. All have 1⁄4” M. NPT connections and are
machined from brass.

Part Number Description


970 Hard nose POL with wrench nut.
970 970AX 970AXS 970AW 970HT 970S
970AX Hard nose POL with wrench nut and excess flow.
970AXS Soft nose POL with wrench nut and excess flow.
3199W Heavy duty hard nose POL with wrench nut and excess flow.
970AW Soft nose POL with Handwheel. 3199W
970HT Soft nose POL with Handwheel and 60 DMS orifice. 7/8” Hex Male 7/8” Hex Male
1/4” Male
970S Soft nose POL with wrench nut and 60 DMS orifice. Part Number Length - POL - POL
NPT
Short Nipple Short Nipple
612JS12 12” X X
612JS20 20” X X
612PS12 12” X X
612PS20 20” X X

612J Series 0-300 PSIG


0-300 PSIG
612P Series Gauge Tail Pressure Gauge
Pressure Gauge 120
150
180
90 210
R

612J Series Gauge Tail 150 150 612-PG


120 180 120 180 60 240
90 210
R

90 210
R

612-PG 30 270
612-PG 60 240
60 240
0 300
30 270 30

0
270

300
POL (CGA 510)
POL (CGA 510)
0 300

1/4” NPT
POL (CGA 510)
... ECII
MA ...
R

Fully Retained Bleeder Valve Fully Retained Bleeder Valve

A32
Flat Blade Screw Slot Flat Blade Screw Slot

Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Brackets
RegO® Brackets are especially designed for use in installing RegO®
PRODU
Regulators in applications requiring the use of a bracket.
10
O

CT
RE

S
10

Y
Part

NT
E

Y
AR A
WA R R
Number Material For Use With Regulator Model:
2302-31 Cadmium 2302 Series/404B23
2503-22 Plated Steel
LV404 Series, 2503 Series LV4403 Series
2503-19 Aluminum
2503-19 2503-22 2302-31

Manifolds

Tee Check Manifolds


1350R and 1450R

Application
For use in systems that require uninterrupted gas service during
cylinder exchange. Especially for summer cottages, mobile homes
and single appliance loads.
1350R
• Floating disc check minimizes discharge of gas to the atmosphere
when empty cylinder is being replaced.

Features
• Floating disc check minimizes discharge of gas to the atmosphere
when empty cylinder is being replaced.

Materials A
Body............................................................................... Forged Brass
Seat Discs ................................................................ Resilient Rubber

Part Number Inlet Connections Outlet Connection 1450R


PRODU
1350R F. POL M. POL
10
O
G

CT
RE

1450R ¼” Inverted Flare ¼” M. NPT


10

Y
NT

E
Y

AR A
WA R R

Multiple Cylinder Manifolds


1350E and 1450E

Application
Use with suitable pigtails to connect multiple cylinders together. Ideal
for loads that require more than one cylinder to be in service at a
time. UL
®

Features
• Provides a three-way tee function without an internal disc check. 1350E

Materials
Body............................................................................... Forged Brass

Part Number Inlet Connections Outlet Connection PRODU

10
O
1450R
G

CT

1350E F. POL M. POL


RE

1450E ¼” Inverted Flare ¼” M. NPT


10

Y
NT

E
Y

AR
WA R RA

A33
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Test Kits
PRODU

10
O

G
Low Pressure Test Set

CT
RE

S
10

Y
NT
E

Y
AR A
WA R R
2434A Series

This kit provides the equipment necessary for checking regulator


delivery pressure (low pressure) at the appliances. The basic set
contains a 2424A-2 low pressure gauge and a 3 foot — 3⁄16” O.D.
flexible synthetic rubber tube. Adapters are also available.

Part Number Contents Adapters


1328
2434A Test Kit 1331
1332 2434A

1328 Adapter

Water Manometer Kit


PRODU

10
O
1212 Kit

CT
RE
A

S
Application

10

Y
NT
E

Y
AR A
WA R R

The water manometer kit is especially suited for use with low pressure
LP-Gas systems. It is ideal for pressure checks downstream of the
low pressure regulator and at the appliances.

Features
• Flexible tube rolls up for convenient storage with accessories in
compact carry case.
• Magnetic clips allow easy attachment to metal surfaces.
• Flexible spring steel scale is calibrated in inches of water column for
reading to 16” w.c.
• Molded nylon tubing connectors incorporate a rapid shut-off design
in an unbreakable molded top.
• Rapid pressure safety trap prevents loss of fluid due to pressure
surges on both columns.
• Scale is center mounted between columns to eliminate parallax
error and has a full two-inch sliding zero adjustment.
Contents

1—Flexible water manometer which reads up to 16” w.c. of


pressure.
1—Heavy duty, compact carrying case.
1—3⁄4 oz. bottle of Fluorescein Green color concentrate.
2—1⁄8” pipe thread barbed tubing adapters. Part
1—3 foot, 3⁄16” rubber tube. Number Description

1—Rubber tubing adapter and 7⁄16” spud. 1212 KIT Flexible Tube Water Manometer Kit

A34
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Accessories

High Pressure Gauge Adapter PRODU

10
O

CT
2962

RE

S
10

Y
NT
E

Y
AR A
WA R R

Designed for testing high pressure lines. Adapter has 0 to 300 PSIG
gauge. A bleeder valve allows you to bleed down to correct pressure
during pressure tests.

Part Inlet Outlet Pressure Gauge


Number Connection Connection Range (PSIG)
Soft Nose
2962 F. POL 0 - 300
M. POL

2962

Adhesive Warning Labels

These adhesive warning labels are intended for application as close


as possible to the LP-Gas regulator once the regulator has been
installed.

Part
Number Description
LV4403-400 Adhesive Warning Label

A35
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Accessories

Warning Notice

The following warning information, Part Number LV4403-500, is


included with each shipment of regulators to the first purchaser of the
product from the factory.

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors.

Cross Reference by Part Number

1350E................................... A33 302S...................................... A26 LV4403TR96............................. A15


1350R.................................. A33 302V...................................... A26 LV4403Y4................................. A19
1450E................................... A33 302V9.................................... A26 LV4403Y46R............................ A19
1450R.................................. A33 302V9LS............................... A26 A4500Y8................................ F14
AA1582MH................................ A29 3139-18................................. A31 LV5503B4................................. A18
A AA1582MK................................ A29
AA1582ML................................. A29
3139-26................................. A31
3139-38................................. A31
LV5503B6................................. A18
LV5503B8................................. A18
AA1582MW............................... A29 3199W................................... A32 LV5503G4................................. A20
AA1584MH................................ A29 LV3403TR................................. A14 LV5503Y6................................. A19
1584MH............................... A29 LV3403TRV9............................. A14 LV5503Y8................................. A19
X1584ML................................ A30 LV404B23................................... A22 5726B23.............................. A23
AA1584ML................................. A29 LV404B23V9............................... A22 5726B23.............................. A25
1584ML................................ A29 LV404B29................................... A22 5727B23.............................. A23
X1584MN............................... A30 LV404B29V9............................... A22 5727B23.............................. A25
1584MN............................... A29 LV404B4..................................... A21 5754B4................................ A23
AA1584MW............................... A29 LV404B46................................... A21 5754B4................................ A25
AA1586MH................................ A29 LV404B46V9............................... A21 5755B4................................ A23
1586MH............................... A29 LV404B4V9................................. A21 5755B4................................ A25
X1586ML................................... A30 LV404B9..................................... A21 5807.................................... A25
AA1586ML................................. A29 LV404B96................................... A21 5808.................................... A25
1586ML................................ A29 LV404B96V9............................... A21 5820.................................... A25
X1586MN............................... A30 LV404B9V9................................. A21 5828.................................... A25
1586MN............................... A29 LV404Y9..................................... A24 5832.................................... A25
AA1586MW............................... A29 LV4403-400................................ A35 597FA.................................. A28
1588MH............................... A29 LV4403B4................................... A16 597FB................................. A28
1588ML................................ A29 LV4403B46................................. A16 597FC................................. A28
X1588ML0.............................. A30 LV4403B46R.............................. A16 597FD................................. A28
X1588MN............................... A30 LV4403B66................................. A16 612JS12.............................. A32
1588MN............................... A29 LV4403B66R.............................. A16 612JS20.............................. A32
2302-31................................ A33 LV4403B66RA............................ A17 612PS12............................. A32
LV2302A2.................................. A27 LV4403B66RAB.......................... A17 612PS20............................. A32
LV2302P.................................... A27 LV4403SR4................................ A15 970...................................... A32
2503-19................................ A33 LV4403SR9................................ A15 970AX............................... A32
2503-22................................ A33 LV4403SR96.............................. A15 970AXS............................... A32
2962..................................... A35 LV4403TR4................................. A15 970HT................................. A32
302....................................... A26 LV4403TR9................................. A15 970S.................................... A32

A36
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

B B

Section B
Cylinder and Service Valves

B1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability
LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
LIMITED 10 YEAR WARRANTY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, with respect to its products and parts,
Engineered Controls International, Inc. (“ECII”) warrants to the original whether used alone or in combination with others. ECII disclaims all
purchasers the products and repair kits manufactured by it to be free warranties not stated herein.
from defects in materials and workmanship under normal use and
service for a period of 10 years from the date of manufacture. If within
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego LIMITATION OF LIABILITY
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within NOTICE TO USERS OF PRODUCTS
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. The Limited Warranty stated above is a factory warranty to the first
purchasers of ECII products. Since most users have purchased
This warranty does not extend to any product or part that is not these products from ECII distributors, the user must within thirty (30)
installed and used continuously after installation in accordance with days after the user’s discovery of what user believes is a defect,
ECII’s printed instructions, all applicable state and local regulations, notify in writing and return the product to the distributor from whom
and all applicable national standards, such as those promulgated by he purchased the product/part. The distributor may or may not at
NFPA, DOT and ANSI. This warranty does not extend to any product the distributor’s option choose to submit the product/parts to ECII,
or part that has been damaged by accident, misuse, abuse, failure to pursuant to this Limited Warranty. Failure by buyer to give such
maintain, or neglect, nor does it extend to any product or part which written notice within thirty (30) days shall be deemed an absolute and
has been modified, altered, disassembled, or repaired in the field. unconditional waiver of buyer’s claim for such defects. Acceptance
This warranty does not cover any cosmetic issues, such as scratches, of any alleged defective product/parts by ECII’s distributor for
dents, marring, fading of colors or discoloration. replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.
Except as expressly set forth above, and subject to the limitation of

Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
B without notice.

B2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
B
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Cross Reference by Part Number.................................... B20
Cylinder Valves................................................................... B9
Design Features of RegO® Cylinder Valves...................... B8
Safety Warnings................................................................. B4
Service Valves.................................................................. B15
Warnings and Labels........................................................ B18

B3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Cylinder and Service Valves
Safety Warnings Purpose
In its continuing quest for safety, Engineered Controls International, Inc. publishes a series of bulletins explaining
the hazards associated with the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these
factual bulletins will make clear to LP-Gas dealer managers and service personnel, that the utmost care and
attention must be used in the installation, inspection, and maintenance of these products, or problems could
occur which would result in injuries and property damage.

The National Fire Protection Association Pamphlet #58 - 2004 Edition, “Liquified Petroleum Gas Code” states in
Section 1.5 that, “persons who transfer liquid LP-Gas, who are employed to transport LP-Gas, or whose primary
duties fall within the scope of this code shall be trained in proper handling procedures. Refresher training shall
be provided at least every three years. The training shall be documented.” These “ECII® Safety Warnings”
may be useful in training new employees and reminding older employees of hazards that can occur. It is
recommended that all employees be furnished with a copy of NPGA Safety Pamphlet 306, “LP-Gas Regulator
and Valve Inspection and Maintenance.”

These functions, although simple, are extremely critical in the safe


Nature of Warnings operation of an LP-Gas cylinder system.

It is recognized that warnings should be as brief as possible, but the


Abuse of these valves, failure to follow a good installation and
factors involved in cylinder valve failure are many because of the
maintenance program and attempting to use cylinder valves
multiple functions the valve serves. If there is any simple warning, it
beyond their normal service life can result in extremely hazardous
would be:
conditions.

Important Factors:
Check cylinder valves for leaking components every time cylinders 1. Installation: It should not be necessary to remind the readers that
are filled. cylinder valves must be installed and used in strict conformance with
NFPA Pamphlet 58, and all other applicable codes and regulations.
Codes, regulations and manufacturers’ recommendations have been
developed by experts with many years of experience in the LP-
The bulletin is not intended to be an exhaustive treatment of the Gas industry in the interest of safety for users of LP-Gas and all
subject of cylinder valves and certainly does not cover all safety personnel

B practices that should be followed in installation, operation and


maintenance of LP-Gas systems which include cylinder valves.
servicing LP-Gas systems. Failure to fully follow these codes,
regulations and recommendations could result in hazardous
installations.

2. The bonnet and stem seal assembly of a cylinder valve are


extremely critical, since any malfunction could cause external leakage
and spillage. Check bonnet to see that it is in proper position. If there
is any doubt about tightness of threaded connection between bonnet
and body, valve must be repaired in accordance with manufacturers’
repair instructions before cylinder is filled. Handwheel must be in
good condition, stem threads must not be worn or damaged and
bonnet must be properly assembled. This area should be examined
each time the cylinder if filled. A leakage test should be conducted
while the shut-off valve is in the open position during filling.

3. The cylinder outlet connection is usually a female POL. Threads


must be free of dents, gouges and any indication of excessive wear.
Seating surface inside this connection must be smooth and free
of nicks and scratches to assure a gas tight seal when connected
to a male POL cylinder adapter. Cylinder adapter must spin on
freely all the way, without indication of drag, roughness or excessive
looseness, and must then be tightened with a wrench. Connection
must be
checked for leakage.

4. The pressure relief valve is of critical importance: Its proper


operation is vital in avoiding excessive pressures during emergencies,
LP-Gas Cylinder Valves such as overfilling or exposure to excessive heat. No repair of this
device is allowable. Relief valve should be visually inspected and
These valves are mounted in DOT cylinders, and are intended to checked for leaks each time the cylinder is returned for filling. All flow
provide one or more of the following functions: passages must be clean and free of foreign material.
1. Vapor service shut-off
2. Liquid service shut-off (with excess flow valve)
3. Liquid filling
4. Pressure relief
5. Fixed liquid level gauge

B4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Cylinder and Service Valves

Entire assembly must be free of dents, distortion or other indications


of damage. If relief valve appears to contaminated or damaged, the
cylinder valve must be replaced. (Caution: Eye protection must be
used when examining relief valves under pressure.)

5. The liquid service shut-off valve, with excess flow valve provided
on some cylinder valves, is also of critical importance. The excess
flow valve must be periodically tested for proper performance, in
addition to the inspection of the shut-off valve.

6. The fixed liquid level gauge on a cylinder valve is, when present,
essential to prevent overfilling the cylinder. The gauging valve must
operate freely, venting vapor when loosened, and sealing gas-tight
easily when tightened with the fingers. Gauge valves meant for
use with a socket key or screwdriver must also seal easily without
excessive torque. The fixed liquid level gauge diptube must be of
the proper length, and be in proper position. Periodic test should be
conducted by weighing the cylinder after filling, to determine that it
does not contain more than the allowable amount of LP-Gas. This At the very minimum, it is desirable that these customers:
check should be done periodically, and any time there is suspicion
that the gauge diptube may be damaged or broken. 1. Know the odor of LP-Gas and what to do in case they smell gas.
Use of the NPGA “Scratch ’n Sniff” leaflet could be productive.

2. Are instructed never to tamper with the system.

3. Know that when protective hoods are used to enclose regulators


and/or valves, that these hoods must be closed, but not locked.

4. Know the location of the cylinder shut-off valve in emergencies.


Do Not Overfill Cylinders

Do not fill a cylinder without first repairing or replacing the


cylinder valve, as required, if any defect is noted. B
While not required by codes, it is recommended that a plug or General Warning
suitable protection be inserted in the POL outlet of the cylinder
valve at all times except during filling and while connected for use.
This will guard against discharge of gas should the handwheel be All ECII® Products are mechanical devices that will eventually
inadvertently opened while the cylinder is in storage or transit. This is become inoperative due to wear, contaminants, corrosion and
highly advisable for small cylinders that could be transported inside aging of components made of materials such as metal and
an automobile or trunk. It is important that proper wrenches and rubber.
adapters be used when filling, servicing and installing cylinder valves
in order to avoid damage to the valve or associated piping.

The environment and conditions of use will determine the safe service
life of these products. Periodic inspection and maintenance are
essential. Because ECII® Products have a long and proven record
of quality and service, LP-Gas dealers may forget the hazards that
Since cylinders are often used by consumers without previous can occur because a cylinder valve is used beyond its safe service
knowledge of the hazards of LP-Gases and the LP-Gas dealers life. Life of a cylinder valve is determined by the environment in which
are the only ones who have direct contact with the consumers, it it “lives”. The LP-Gas dealers know better than anyone what this
is the dealers’ responsibility to make sure that his customers environment is. NOTE: There is a developing trend in state legislation
are properly instructed in safety matters relating to their and in proposed national legislation to make the owners of products
installation. responsible for replacing products before they reach the end of their
safe useful life. LPGas dealers should be aware of legislation which
could affect them.

B5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Thread Specifications

Cylinder Valve Threads Because of the many thread forms available on equipment used in
the LP-Gas industry today, the maze of letters, numbers and symbols
which make up various thread specifications becomes confusing. To
help eliminate some of this confusion, a brief explanation of some of
the more widely used thread specifications is shown below.

NGT and NPT Threads


Inlet Connections The NGT (National Gas Taper) thread is the commonly used valve-
to-cylinder connection. The male thread on the valve has about
two more threads at the large end than the NPT in order to provide
additional fresh threads if further tightening is necessary. Additionally,
the standard 3⁄4” NGT valve inlet provides the greater tightness at
the bottom of the valve by making the valve threads slightly straighter
than the standard taper of 3⁄4” per foot in NPT connections. In all
other respects NPT and NGT threads are similar.
Hand engagement of all
Overall length of all except NGT
Overall length of NGT

Outlet Connections
CGA Outlets
The CGA (Compressed Gas Association) outlets are standard for use
with various compressed gases. The relation of one of these outlets Copper Tubing
Cylinder
Valve
to another is fixed so as to minimize undesirable connections. They Nut
Outlet
have been so designed to prevent the interchange of connections
which may result in a hazard.
CGA 182, or SAE Flare
This connection assures a leak-tight joining of copper tubing to brass
3/8”-18 NPT Thread Connection
parts without need for brazing or silver soldering. The common size
This connection also is used for vapor or liquid withdrawal. It has a
B 3⁄8” diameter thread, and 18 threads per inch, National Pipe Taper
used on LP-Gas valves and fittings is 3⁄8” SAE (Society of Automotive
Engineers) flare. Although this connection is referred to as a 3⁄8”,
Outlet form.
because 3⁄8” OD tubing is used, the thread actually measures 5⁄8”.
The specifications are .625 – 18 UNF – 2A – RH – EXT, which means
Cylinder Valve Outlet .625” diameter thread, 18 threads per inch, Unified Fine Series Class
2 Tolerances, right-hand, external thread.

Nipple
Nut
CGA 555
CGA 555 is the standard cylinder valve outlet connection for liquid
withdrawal of butane and/or propane. Thread specification is .903” –
14 NGO – LH – EXT, which means .903” diameter thread, 14 threads Cylinder
Nipple Valve
per inch, National Gas Outlet form, left-hand external thread. Nut Outlet

1 5⁄16 " Female ACME


- Right Hand CGA 510 or POL
Most widely used in this industry, POL is the common name for the
standard CGA 510 connection. Thread specification is .885” – 14
Back Check Assembly
NGO – LH – INT, meaning .885” diameter thread, 14 threads per inch,
[Link], CGA 510
National Gas Outlet form, left-hand internal thread. ECII® POL outlet
connections for LP-Gases conform to this standard.

Type I Outlet
This connection is designed to mate with either a 15⁄16” Female
ACME or a Male POL (CGA510). It complies with the ANSI Z21.58
Standard for Outdoor Cooking Appliances and the Can/CGA-1.6
Standard for Container Connections. A back check assembly in the
outlet is designed to prevent gas flow until a leak free connection is
made with an inlet adapter. These standards apply to barbecue grill
cylinders manufactured after October 1994.

B6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Cylinder and Service Valves
Heavy-Duty Valve Stem Seals
General Information ECII®/RegO® Cylinder Valves utilize seat discs and stem seals which
The wide acceptance of ECII®/RegO® Cylinder Valves is based on resist deterioration and provide the kind of reliable service required
their reliable performance as well as their reputation for engineering for LP-Gas utilization. Diaphragm or O-Ring stem seals are available.
and manufacturing excellence. Together with thorough testing, these Valves with diaphragm stem seals are recognized for their heavy-
efforts result in years of trouble-free service. ECII®/RegO® Cylinder duty body design and are suitable for use in cylinders up to 200
Valves are listed by Underwriters’ Laboratories and approved by the lbs. propane capacity. O-Ring type stem seals are the most widely
Bureau of Explosives for pressure relief valve operation, wherever accepted in the industry. The simple, economical and long life design
applicable. See section on relief valves for important information. features a tapered and confined nylon seat disc which provides
positive, hand-tight closings, and a faster filling cylinder valve.

Reliability Pressure Relief


ECII®/RegO® Cylinder Valves are built with attention to each ECII®/RegO® Valves have full-capacity “pop action” pressure reliefs
detail: Beginning with comprehensive inspection of forgings and with start to discharge settings at 375 PSIG.
machined parts, and ending with intense quality testing on each
individual valve prior to shipment. Every valve must pass a stringent
and comprehensive underwater leakage test. Additionally, valves A Valve for Every Need
with pressure reliefs are tested for proper pressure and operation, ECII®/RegO® Cylinder Valves are available for all LP-Gas services;
including reseating to ensure proper opening and closing at required a wide choice for domestic, commercial, industrial, RV, motor fuel,
pressures. Those equipped with excess flow checks are tested and lift truck applications. Valves are available with a combination
for compliance with published closing specifications, and tested to of such options as pressure reliefs, liquid level gauges, and liquid
ensure minimum leakage after closing. withdrawal tubes. Also available for special applications are plumbers’
pot valves, tamperresistant valves for field service, and dual valves
for simultaneous liquid and vapor service.

Instructions for the Proper Use and Applications 2. Do not use excessive force in opening or closing the valves. The
of ECII®/RegO® Cylinder Valves seat disc and diaphragm materials permit the valves to be opened
and closed easily by hand. Never use a wrench on wheel handle
1. Containers and pipe line should be cleaned thoroughly before valves. B
valves are installed. Large particles of solid foreign matter can cut the
seating surface of any resilient seat disc, causing the valve to leak. 3. When the design of the piping installation allows liquid to be locked
Care must be exercised in inserting valves into lines or containers to between two valves, a hydrostatic relief valve must be installed in the
avoid damaging or exerting pressure against pressure relief valves line between the two valves. The pressures which can develop due
and outlet connections. Use a minimum amount of a suitable luting to temperature increase in a liquid full line are tremendous and can
compound on the cylinder valve threads only. Excess amounts of cause rupture of the line or damage to the valves.
luting compound can foul the operating parts of the valves.
4. The valves are designed to withstand normal atmospheric
temperatures. They should not, however, be subjected to abnormally
high temperatures.

B7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Design Features of ECII® / RegO® Cylinder Valves

Valve Stems On 901, 903, 9101 and Back Seat On 901, 9101 and
9103 Valves 9103 Valves
Are machined with a double lead thread Is metal-to-metal seating to provide
for quick opening and closing as well as added protection against leakage
high lift. whilethe valve is open. Back seat the
valve while in operation.

Forged Brass Body

Pressure Relief O-Rings


Provides quick discharge of excess For positive leak-proof seals under
pressure. Relief seat disc is special temperature and pressure ariations.
resilient composition rubber.

Seat Disc
Tapered Seat Openings Is a tapered nylon in a fully confined
On 9101 and 9103 Valves seat to ensure easy, leak-free, positive
Permit increased flow rates shutoffs. Seat disc also provides a
resulting in faster charging. separate swivel action to minimize
scoring by impurities.

B8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Heavy-Duty Cylinder Valves for Vapor Withdrawal
9103 Series

Application
This heavy duty cylinder valve is designed for vapor withdrawal of
DOT cylinders up to 100 lbs. propane capacity. It is used in domestic
hookups, and industrial commercial installations.

Features
• Equipped with a fast filling throat and high lift, o-ring stem seal
design.

• Utilizes a nylon tapered seat design for positive closing.

• Available with a fixed liquid level gauge.


UL
®

• Self-tapping screw secures handwheel to stem and reduces


possibility of handwheel vibrating loose while in transit.

Materials
Body............................................................................... Forged Brass
Handwheel.......................................................................... Aluminum 9103D
Stem........................................................................................... Brass
O-Rings..................................................................... Resilient Rubber
Seat Disc.................................................................................... Nylon
Relief Spring................................................................ Stainless Steel

PRODU B

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Fixed For Use in Approximate Filling Rate Liquid Flow, GPM Accessories
Pressure
Liquid Dip Tube Cylinders
Part Container Service Relief Pressure Drop Across Valves
Level Vent Length w/ w/Propane
Number Connection Connection Valve POL Plug
Valve Deflector Capacity
Setting 10 PSIG 25 PSIG 50 PSIG 100 PSIG
Style Up To:
9103D10.6 F. POL 10.6”
3/4” M NGT Knurled 375 PSIG 100 lbs. 12.7 20.3 29.0 41.3 N970P
9103D11.6 (CGA 510) 11.6”

Approximate Filling Rate Liquid Flow, GPM Closing Flow (LP-Gas) *


Pressure Relief For Use in Cylinders w/
Pressure Drop Across Valves Vapor
Valve Setting Propane Capacity Up To: Liquid
10 PSIG 25 PSIG 50 PSIG 100 PSIG 25 PSIG Inlet 100 PSIG Inlet
375 PSIG 100 lbs. 3.3 5.4 7.7 11.1 525 SCFH 1,000 SCFH 1.7 GPM
*Closing flows based on ⁄ ” O.D. withdrawal tube 44” long or less attached.
38

IMPORTANT: 1⁄4” O.D. pigtails or POL connections for 1⁄4” O.D. pigtails should not be used with these valves.
NOTES: To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened
and backseated when in use. These valves incorporate an excess flow valve. Refer to L-500 / Section F, for complete information
regarding selection, operation and testing of excess flow valves.
B9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Tamper-Resistant Cylinder Valve with Outlet Check
for Vapor Withdrawal 9103T9F

Application
UL
®

This valve is designed for vapor withdrawal from and protection of


DOT cylinders up to 100 lbs. propane capacity. Ideal for cylinders
used in the field by construction crews, utility repair men and
plumbers.

Features
• Minimizes the risk of unauthorized persons withdrawing propane
from cylinders not in service. It is necessary to install a male POL
connection to open the outlet check to withdraw vapor from the
valve.

• Ball type excess flow located in the valve inlet protects against
excessive discharge if the cylinder is tipped or the hose ruptures.
Closing flow is 200 SCFH at 100 PSIG.

• Removable POL outlet and check mechanism make field


replacement of worn connections an easy process without
removing the valve from the cylinder.

• Outlet seal plug on a heavy duty chain prevents dirt from entering
POL when not in use.

• Nylon tapered seat design provides positive closure.

B
Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Stem........................................................................................... Brass
O-Rings..................................................................... Resilient Rubber
Seat Disc.................................................................................... Nylon
Relief Spring................................................................ Stainless Steel
Plug............................................................................................ Brass

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Approximate Filling Rate Liquid Flow, GPM
Fixed Liquid Pressure
Part Container Service For Use in Cylinders w/
Level Vent Relief Valve Pressure Drop Across Valves
Number Connection Connection Propane Capacity Up To:
Valve Style Setting
10 PSIG 25 PSIG 50 PSIG 100 PSIG
¾” F. POL 375
9103T9F None 100 lbs. 5.0 7.6 10.7 14.9
M. NGT (CGA 510) PSIG

NOTE: These valves incorporate an excess flow valve.


Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cylinder Valve for RV and Small ASME System Vapor Withdrawal
9106CO

Application
Designed especially for vapor withdrawal service in small ASME
containers with surface area up to 23.8 square feet. UL flow capacity
is 645 SCFM/air.

Features
• One-piece relief valve is shielded from tampering and damage.
UL
®

• Relief is forged as part of the body for extra strength.

• 312 PSIG Relief Valve setting.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Stem........................................................................................... Brass
Seat Disc.................................................................................... Nylon
Relief Spring................................................................ Stainless Steel

PRODU 4 5⁄16 "

10
O
Approx.
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

2 1⁄32 " 1 3⁄8"

Ordering Information
Container Service Fixed Liquid Level Pressure Relief Valve For Use In Cylinders w/ Propane Flow Capacity
Part Number
Connection Connection Vent Valve Style Setting Capacity Up To SCFM/Air
¾” F. POL 312 ASME
9106CO none 645
M. NGT (CGA 510) PSIG Tanks*
* Surface area up to 23.8 square feet.

B11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cylinder Valve for Liquid Withdrawal
9107K8A

Application
Equipped with excess flow valves and liquid withdrawal tubes, they
are designed for liquid withdrawal of DOT cylinders up to 100 lbs.
propane capacity. They are most often used with heavy BTU loads
found in industrial uses.

Features
• O-ring stem seal design.

• Nylon tapered seat disc for positive closure.

• Self-tapping screw secures handwheel to stem and reduces UL


®

possibility of handwheel vibrating loose while in transit.

• Features ball check excess flow valve.

• Furnished with 3⁄8” O.D. stainless steel withdrawal tube with


“T’’ dimension of 44”.

Materials
Body............................................................................... Forged Brass
B Handwheel............................................................ Aluminum Die Cast
Seat Disc.................................................................................... Nylon
O-Rings..................................................................... Resilient Rubber
Relief Spring................................................................ Stainless Steel
Stem........................................................................................... Brass

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Container Fixed Liquid Level Vent Valve Dip Tube Length w/
Part Number Service Connection Liquid Withdrawl Tube Length
Connection Style Deflector
¾”
9107K8A CGA 555 Knurled 11.6” 44”
M. NGT

B12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
“Dual” Cylinder Valve for Simultaneous Liquid and Vapor Withdrawal
8556

Application
UL
®

This dual cylinder valve was designed especially for industrial uses.
It increases the cylinder’s flexibility by permitting DOT cylinders
up to 100 lbs. propane capacity to be used interchangeably or
simultaneously for either liquid or vapor withdrawal.

Features
• Two separate flow channels in the body permit vapor and/or liquid
withdrawal alternately, or simultaneously.

• Outlet connections have two different fittings.

• Handwheels are equipped with appropriate “liquid” or “vapor”


identification labels.

• Furnished with a 3⁄8” O.D. stainless steel liquid withdrawal tube with
a “T” dimension of 44”.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast B
Stem........................................................................................... Brass
Seat Disc.................................................................................... Nylon
O-Rings..................................................................... Resilient Rubber
Relief Spring................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Container Service Connection
Part Number Fixed Liquid Level Vent Valve Style Liquid Withdrawl Tube Length
Connection Vapor Liquid

8556 ¾” M. NGT F. POL (CGA 510) CGA 555 None 44”

Approximate Filling Rate Liquid Flow, GPM


Pressure Relief For Use in Cylinders w/ Liquid Closing Flow*
Pressure Drop Across Valves
Valve Setting Propane Capacity Up To: (LP-Gas)
10 PSIG 25 PSIG 50 PSIG 100 PSIG
375 PSIG 100 lbs. 6.6 10.0 14.5 21.0 2.3 GPM

*
To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use.
NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Service Valves for ASME and DOT Containers or Fuel Line Applications
901C1, 9101C, 9101D, and 9101R Series

UL
Application ®

Designed for vapor withdrawal service on ASME and DOT containers


or in fuel line applications. Since none of these valves have an
integral pressure relief valve, they may only be used as an accessory
valve on containers that have an independent pressure relief valve
sufficient for that container’s capacity.

Features
• O-Ring stem seal design provides positive seal.

• Metal-to-metal back seat provides added protection against leakage


while the valve is open.
901C1
• Valves with fixed liquid level gauges permit operator to quickly
determine when the maximum permitted filling level of the
container is reached.

• 9101R Series with MultiBonnet allows quick and easy repair of


bonnet.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Stem........................................................................................... Brass
B O-Rings..................................................... Resilient Synthetic Rubber
Seat Disc.................................................................................... Nylon 9101R1

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

9101D

Ordering Information
Approximate Filling Rate Liquid Flow, GPM
Fixed Liquid Pressure Drop Across Valve
Container Service Level Vent
Part Number Bonnet Style Connection Connection Valve 10 PSIG 25 PSIG 50 PSIG 100 PSIG
901C1 5.3 8.2 10.8 14.2
No
9101C1 8.8 12.4 15.8 21.7
Standard
9101D11.1
F. POL Yes 8.6 12.7 16.3 22.3
9101D11.7 ¾” M. NGT
CGA 510
9101R1 No
9101R11.1 MultiBonnet 7.6 11.7 15.2 20.6
Yes
9101R11.7

Note Since these valves have no integral pressure relief valve, they can be used on any container with an independant relief device sufficient for that tank’s capacity.

B14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Service Valves for ASME Motor Fuel Containers
901C, 9101H, and 9101Y Series
Application
Designed specifically for vapor or liquid withdrawal service on ASME
UL
®

motor fuel containers. Since none of these valves have an integral


pressure relief valve, they may only be used as an accessory valve
on containers that have an independent pressure relief valve sufficient
for that container’s capacity.

The integral excess flow valve found in all these service valves helps
prevent excessive product loss in the event of fuel line rupture.

When installed for liquid withdrawal, the 9101H6 has provisions


901C5
for attachment of a liquid withdrawal tube. All other valves must
be installed in containers that have provisions for a separate liquid
withdrawal.

To insure proper functioning and maximum protection from integral


excess flow valves, these service valves should be fully opened and
backseated when in use.

Features
• Incorporates integral excess flow valve and shut-off valve in one
unit. 9101H5

• Double lead thread provides faster opening and closing.

• O-Ring stem seal design provides positive seal.

• Tapered and confined seat disc provides positive shut off.

B
• Metal-to-metal back seat provides added protection against leakage
while the valve is open.

• 9101H6 equipped with a 1⁄4” NPT internal thread for the addition of
a liquid withdrawal tube.

• 9101Y Series features a 60º angled outlet connection to facilitate


easier and simpler fuel line make-up.
9101H6

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Stem........................................................................................... Brass
O-Rings..................................................... Resilient Synthetic Rubber
Seat Disc.................................................................................... Nylon

9101Y5H
Ordering Information
Closing Flow (LP Gas)
Liquid Vapor
Container Service Withdrawal
Part Number Connection Connection Connection 25 PSIG Inlet (SCFH) 100 PSIG Inlet (SCFH) Liquid GPM
901C3 350*** 605*** 1.5***
F. POL CGA 510
901C5 None 550*** 1050*** 2.6***
9101H5* 765** 1300** 3.6**
¾”M. NGT ⅜” SAE Flare
9101H6* ¼” NPT 550**** 1050**** 2.6****
60° Angle
9101Y5H* None 550** 1050** 3.6**
⅜” SAE Flare
* Heavy-duty models PRODU

10
O
** Based on 3⁄8” O.D. pigtail, 20” long or less, connected to valve outlet. For greater lengths, the pigtail must have a larger O.D.
G

CT
RE

*** Same as (**). In addition, 1⁄4” O.D. pigtails or POL connections for 1⁄4” O.D. should not be used with this valve.
**** Based on 3⁄8” O.D. pigtail; 20: long or less, connected to valve outlet. Also based on 1⁄4” pipe size dip tube, 42” long or less, attached to special inlet
10

Y
NT

E
connection. For longer pigtail lengths, the diameter of the pigtail must be increased.
Y

AR
WA R R
A

NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
B15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Service Valves for DOT Fork Lift Containers
9101P5 and 9101P6 Series

Application
Designed specifically for vapor or liquid withdrawal service on DOT
fork lift containers. Valves with 1.5 GPM closing flow are for use in
small and medium size lift truck applications, while those with 2.6
GPM closing flow are for large lift trucks. Since none of these valves
have an integral pressure relief valve, they may only be used as an
accessory valve on containers that have an independent pressure
relief valve sufficient for that cylinders capacity.

The integral excess flow valve found in all these service valves helps
prevent excessive product loss in the event of fuel line rupture.

When installed for liquid withdrawal, the 9101P6 Series has provisions
for attachment of a liquid withdrawal tube. The 9101P5 Series must
be installed in containers that have provisions for a separate liquid
withdrawal.

To insure proper functioning and maximum protection for integral


excess flow valves, these service valves should be fully opened and
backseated when in use.
UL
®
9101P5
Features 9101P5H

• Incorporates integral excess check valve and shut-off valve in one


unit.

• Special 1.5 GPM closing flow on select valves provided especially


for lift trucks and equipment with smaller engines.

• Double lead stem thread provides faster opening and closing.


B • O-Ring stem seal design provides positive seal.

• Tapered and confined seat disc provides positive shut-off.

• Metal-to-metal back seat provides added protection against leakage


while the valve is open.

• 9101P6 Series equipped with a 1⁄4” NPT internal thread for the
addition of a liquid withdrawal tube.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast 9101P6 PRODU

10
O
Stem........................................................................................... Brass 9101P6H
G

CT
RE

O-Rings..................................................... Resilient Synthetic Rubber


S

Seat Disc.................................................................................... Nylon


10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Approximate Filling Rate Liquid
Closing Flow (LP-Gas) Flow, GPM Accessories

Vapor Pressure Drop Across Valve ACME Check Connectors


Liquid
Part Container Service Withdrawal 25 PSIG 100 PSIG Liquid 10 25 50 100
Number Connection Connection Connection Inlet (SCFH) Inlet (SCFH) (GPM) PSIG PSIG PSIG PSIG Male Female Cap
9101P5 430 900 1.5
None 5.0 7.6 10.7 14.9
9101P5H 550 1050 2.6 7141M-40
¾” M. NGT ⅜” M. NPT 7141M 7141F
9101P6 430 900 1.5 or 7141FP
¼” NPT 4.5 7.2 10.3 14.8
9101P6H 550 1050 2.6
Note: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Adhesive Warning Labels
901-400 and 903-400

These adhesive warning labels are intended for application as close


as possible to the cylinder valve and/or service valve. Part Number
Adhesive Label Primarily for Fork Lift
901-400
The basic information contained on the label is intended for the Cylinders
benefit of the user of the valves and is not intended to be an “all- Adhesive Label Primarily for Small
inclusive” product warning. 903-400
DOT Cylinders

These labels are printed on a heavy duty material with pressure


sensitive adhesive backing. The ultra-violet ink stands up well when
exposed to the enviroment.

DANGER LP GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE WARNING


AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL, OR HEAR ESCAPING GAS...EVACUATE AREA
IMMEDIATELY! CALL YOUR LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
This container is filled with highly flammable LP-Gas under pressure. A Do not allow any [Link] the fixed liquid level gauge is used during filling, filling
serious fire or explosion can result from leaks and misuse or mishandlingof should stop the moment a white LP-Gas cloud is emitted from its bleed hole.
the container and its valves. Do not move, hold or lift the container by any Keep the vent closed tightly at all other times. Each time the container is filled,
of its [Link] not expose to fire or temperature above 120°F (49°C). Do it must be checked for leaks (with a high quality leak detection solution...leaks
not overfill. cause bubbles to grow).
This container incorporates a pressure relief valve. The pressure relief valve Do not disconnect or connect this container without first reading the instructions
can expel a large jet of LP-Gas into the air if the container is (1) exposed to accompanying the vehicle or appliance with which this container is intended to
high temperatures—over120°F (49°C) or (2) overfilled and exposed toa be used. CAUTION...no smoking while connecting or disconnecting this
temperature higher than the temperatures at the time it was filled. container .
The pressurereliefvalveis equipped with a protective cover. The protective Make sure the service valve is shut off tightly before beginning to assemble or
cover must remain in place at all times except when inspecting the disassemble the coupling. Liquid LP-Gas may flow or leak from the coupling.
valve. CAUTION...useeye protection. If dust, dirt, moisture or other foreign This liquid can cause skin burns, frost bite and other serious injury in addition to
materialcollect in the valve,it may not function properly to prevent container those caused by fire and explosion. CAUTION...Wear proper skin and eye
rupture or minimize product loss after opening. protection. Any gasket or O-ring in the coupling must be routinely checked for
Each time the container is filled, the pressure relief valve must be checked wear and replaced as required.
to ensure that it is completely unobstructed and that it has no physical After connecting the coupling, make sure the connection is leak tight. Check for
damage. If there is any doubt about the condition of the valve,the container leaks with a high quality leak detection solution (leaks cause bubbles to grow).
must be removed from service and the pressure relief valve must be If the connection leaks after tightening, close the service valve, disconnect the
replaced. coupling and remove from service.
Only trained personnel should be permitted to fill this container. Before the When not in use, keep the service shut-off valve closed.
container is filled for the first time, it must be purged of air. The total liquid When in use, keep the service valve fully open.
volume of LP-Gas must never exceed the amount designated by
Keep this equipment out of the reach of children.
applicable filling density regulations for this container.
This container must be used only in compliance with all applicable laws and
Make sure the protective cap is in place on the ACME threaded filler valve regulations, including National Fire Protection Association Publication No. 58,
at all times. Never insert a screwdriver or other tools into the valve as it can
which is the law in many states. A copy of this Publication may be obtained by
damage the seal or guide and cause an uncontrolled leak. writing NFPA, Batterymarch Park, Quincy, MA 02269.

B
DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL—DO NOT FILL THIS CONTAINER UNLESS THIS LABEL IS READABLE.
ADDITIONAL SAFETY INFORMATION
IS AVAILABLE FROM: Engineer ed Cont ro ls
® International, Inc. Printed in U.S.A. 04-0994-1189 Part No. 901-400
100 RegO Drive PO Box 247 Elon College, NC 27244 USA Phone (336) 449-7707 Fax (336) 449-6594 www .regoproducts.c om

DANGER! LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE


KEEP CYLINDER OUT OF THE REACH OF CHILDREN WARNING!
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL, OR HEAR THE HISS OF ESCAPING GAS... IMMEDIATELY GET AWAY FROM THIS CYLINDER! CALL YOUR
LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT USE OR STORE IN BUILDING OR ENCLOSED [Link] OUTDOOR USE ONLY.
This cylinder contains highly flammable LP-Gas under pressure. A serious CAUTION...eye protection must be worn when examiningreliefvalve. This WHEN MAKING CONNECTIONS TO AN APPLIANCE—
fire or explosion can result from leaks and misuse or mishandling of the valvecannot be [Link] it is obstructed, the entire cylinder valvemust be 1. Do not use this cylinderwithout first readingthe instructionsaccompa-
cylinder and its valve. Do not carry, hold or lift the cylinder by its valve. replaced. The Shut-Off Valve may require periodic repair or replacement. nying the appliance with which this cylinder is intended to be used .
Do not expose to fire or temperatures above 120°F (49°C). Before the cylinder is filled for the first time, it must be purged of air. 2. Before connecting the Cylinder Valve outlet connection to an appli-
The cylinder valveincorporates a Shut-Off Valveand PressureReliefValve. Total liquid volume must never exceed the amount designated by DOT ance, make sure the connection does not contain dirt or debris. These
The Pressure-ReliefValve can expel a large jet of LP-Gas into the air if the for this cylinder. may cause the connection to leak or may impair the functioning of the
cylinder is (1) exposed to high temperatures —over 120°F (49° C.), or (2) If the cylinder has a fixed liquid level gauge, filling should stop the regulator, creating a hazardous condition.
overfilledand exposed to a temperature higher than the temperature at the moment a white LP-Gas cloud is emitted from its bleed hole. Keep the 3. When connecting the Cylinder Valve outlet to an appliance
time it was filled. vent valve closed tightly at all other times. (CAUTION...counterclockwisethread), make sure the connection is
Never attempt to fill this cylinder yourself. Do not tamper with it or Keep this cylinder firmly secured in an upright position at all times. Do tight. Check for leaks with a high quality leak detection solution (leaks
attempt repairs. not lay it on its side during transport, storage or use. In other than an upright cause bubbles to grow). If the connection leaks after tightening, close
Only trained LP-Gas Dealer personnel should be permitted to fill this position, liquid LP-Gas may flow or leak. This liquid can cause skin burns, cylinder valve,disconnect it from the appliance, insert the P.O.L. plug
cylinder and to repair or replace its valve. Each time the cylinder is frostbite and other serious injuries in addition to those caused by fire or and immediatelyreturn the cylinder, with the CylinderValveattached,
filled, the entire cylinder valve must be checked for leaks (with a leak explosion. to your LP-Gas Dealer for examination.
detection solution...leaks cause bubbles to grow). The shut-off valve When not in use: Close the Shut-Off [Link] a protective plug (P.O.L. This cylinder must be used only in compliance with all applicable laws and
and fixed liquid level gauge (if incorporated) must be checked for plug) into the cylinder valve outlet. (CAUTION...counterclockwisethread). regulations, including National Fire Protection Association Publication No.
proper operation. The Pressure-ReliefValve must be checked to ensure The P.O.L. plug must be inserted wheneverthe cylinder is stored, manually 58, which is the law in many states. A copy of this Publication may be
that it is completely unobstructed and that it has no physical damage. moved, or transported by vehicle. obtained by writing NFPA, Batterymarch Park, Quincy, MA 02269.

DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL—DO NOT FILL THIS CYLINDER UNLESS THIS LABEL IS READABLE.
ADDITIONAL SAFETY INFORMATION 100 RegO Drive PO Box 247 Elon College, NC 27244 USA Printed in U.S.A. 05-0994-1086
IS AVAILABLE FROM: Phone (336) 449-7707 Fax (336) 449-6594 [Link] Warning No. 903-400

B17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Warning Notice

The following warning information, Part Number 903-500, is included


with each shipment of cylinder valves and service valves to the first
purchaser of the product from the factory.

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors.

B18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cross Reference by Part Number
8556................................................................................................B13 9101P5H.........................................................................................B16
901-400...........................................................................................B17 9101P6............................................................................................B16
901C1.............................................................................................B14 9101P6H.........................................................................................B16
901C3.............................................................................................B15 9101R1...........................................................................................B14
901C5.............................................................................................B15 9101R11.1.......................................................................................B14
903-400...........................................................................................B17 9101R11.7.......................................................................................B14
9101C1...........................................................................................B14 9101Y5H.........................................................................................B15
9101D11.1.......................................................................................B14 9103D10.6........................................................................................B9
9101D11.7.......................................................................................B14 9103D11.6.........................................................................................B9
9101H5...........................................................................................B15 9103T9F..........................................................................................B10
9101H6...........................................................................................B15 9106CO........................................................................................... B11
9101P5............................................................................................B16 9107K8A.........................................................................................B12

B19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
B

B20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

C C

Section C
Multivalve® Assemblies

C1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability
LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
LIMITED 10 YEAR WARRANTY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, with respect to its products and parts,
Engineered Controls International, Inc. (“ECII”) warrants to the original whether used alone or in combination with others. ECII disclaims all
purchasers the products and repair kits manufactured by it to be free warranties not stated herein.
from defects in materials and workmanship under normal use and
service for a period of 10 years from the date of manufacture. If within
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego LIMITATION OF LIABILITY
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within NOTICE TO USERS OF PRODUCTS
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. The Limited Warranty stated above is a factory warranty to the first
purchasers of ECII products. Since most users have purchased
This warranty does not extend to any product or part that is not these products from ECII distributors, the user must within thirty (30)
installed and used continuously after installation in accordance with days after the user’s discovery of what user believes is a defect,
ECII’s printed instructions, all applicable state and local regulations, notify in writing and return the product to the distributor from whom
and all applicable national standards, such as those promulgated by he purchased the product/part. The distributor may or may not at
NFPA, DOT and ANSI. This warranty does not extend to any product the distributor’s option choose to submit the product/parts to ECII,
or part that has been damaged by accident, misuse, abuse, failure to pursuant to this Limited Warranty. Failure by buyer to give such
maintain, or neglect, nor does it extend to any product or part which written notice within thirty (30) days shall be deemed an absolute and
has been modified, altered, disassembled, or repaired in the field. unconditional waiver of buyer’s claim for such defects. Acceptance
This warranty does not cover any cosmetic issues, such as scratches, of any alleged defective product/parts by ECII’s distributor for
dents, marring, fading of colors or discoloration. replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.
Except as expressly set forth above, and subject to the limitation of

Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
C without notice.

C2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
C
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Cross Reference by Part Number................................................. C12
Multivalve® Assemblies................................................................... C4
Warnings....................................................................................... C12

C3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO Multivalve® Assemblies
General Information Comprehensive Testing —
RegO Multivalves were pioneered in the 1930’s. By combining several
® • Every Multivalve® must pass a stringent underwater leakage test
valve functions in one unit, Multivalves® made possible new and more prior to shipment.
practical tank designs (fewer openings and smaller, less cumbersome • Multivalves® with pressure relief valves are individually tested and
protective hoods). They received immediate acceptance. adjusted to assure proper pressure settings.
The Multivalve® design has kept pace with changing industry needs • Those equipped with excess flow checks are tested for compliance
over the years. They are as popular as ever; still keeping fabricating with published closing specifications and for leakage after closing.
costs down and reducing operating expenses for the LP-Gas dealer. Pressure Relief Valves and Other Devices —
RegO Multivalves® Reduce the Cost of Fabrication by • Multivalves® equipped with integral pressure relief devices employ
• Combining several valve functions in one less expensive body. full-capacity, “pop-action” reliefs with set pressures of 250 psig for
ASME use and 375 psig for DOT cylinders.
• Reducing the number of threaded openings in ASME containers.
Double Back-Check Filler Valves —
• Diminishing the size and cost of protective hoods.
• Multivalves® with filling connections have double backcheck safety.
• Providing generous sized wrenching bosses for quick, easy
If the upper check ceases to function, the lower stand-by check will
installation.
continue to protect the filling connection from excessive leakage.
RegO Multivalves® Reduce LPG Dealer Expenses by
Ease of Maintenance —
• Permitting on-site filling of 100 lb. to 420 lb. DOT cylinders, thus
• Standardization of parts makes it possible for one repair kit to
eliminating cylinder return and interrupted customer service.
maintain the bonnet assemblies of RegO® cylinder valves, service
• Providing well-placed hose connections for easy filling. valves, motor fuel valves, and Multivalves®.
• Allowing ample space for secure attachment and easy removal of RegO Multivalves® fit every LP-Gas need.
the regulator.
• Wide selection of Multivalves® for domestic, commercial, and
• Providing substantial savings of bonnet repairs on valves with the industrial needs are available.
MultiBonnet.®
• Multivalves® may be ordered with pressure relief, liquid level tube,
RegO Multivalves® Satisfy Customer Demands for Tough, Safe filler valve, vapor equalizing valve, internal pipe connections, liquid
Equipment with These Features filling and withdrawal connections, and 1⁄4” NPT tapped opening for
Heavy-Duty Valve Stem Seals — pressure gauge with or without steel plug.
• Tapered nylon disc in a fully confined seat resist deterioration and
provide hand-tight closings over a long service life.

Design Features of RegO Multivalves®


C

Seal Cap
Molded from tough, resilient
plastic to protect threads
and internal working parts.
Designed to protect the filler UL Shear Point
opening against dirt and other Provides for a shear just
foreign materials. Also acts below the ACME threads to
as a secondary pressure seal. protect the container in case
of a pullaway while the hose
Long Wearing Gasket is connected. The ACME
Permits leak-free, hand-tight connection should shear off
connection of the hose on an angle pull, leaving the
coupling to the filler valve. body and check assembly of
the valve still in place.
Forged Brass Body
Filler Seat Disc
Fabricated of special
synthetic composition and
made extra thick for
longer life.
MultiBonnet®
Designed to allow quick and Valve Guide
easy repair of bonnet pack- A precision machined “stem”
ings on Multivalves® on to assure positive alignment
active propane systems.
“Pop Action” Pressure Relief
Provides quick release of
excess pressure. Relief seat
disc is special resilient
composition rubber designed
to resist bonding to the
valve seat even after years
of service.

C4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO Multibonnet® Assemblies

Design Features of the MultiBonnet®

Handwheel
Aluminum die cast handwheel.

Non-Rising Stem
Designed to allow easy backseating and long
service life.

Upper Packing Assembly


Contains both internal and external o-rings.
Provides leak resistant performance.

Internal O-ring

Lower Bonnet and Stem Assembly


Machined brass construction offers durability to
bonnet design.

External O-ring

Nameplate C
Provides easy identification of the RegO
MultiBonnet®.

Teflon Backseat
Provides for upper packing isolation when valve
is fully open.

Machined Double Lead Threads


Provides for quick opening and closing of the
valve.

Shut-off Seat Disc


Tapered nylon disc is retained in a fully confined
seat that helps ensure positive shut-offs.

Application
The MultiBonnet® is designed to allow quick and easy repair of bonnet • Available on certain new Multivalves® and service valves as well as
packings in certain Multivalves® and service valves on active propane repair assemblies for many existing RegO® valves.
systems. It allows you to repair valve bonnet stem o-ring leaks in • UL listed as a component of valve assembly.
minutes, without interrupting gas service to your customers.
Here’s How The MultiBonnet® Works
• Eliminates the need to evacuate tanks or cylinders to repair the
• When the valve is fully open, only the lower stem will rise and
MultiBonnet® packing.
backseat against the teflon washer which isolates the upper
• Two section design allows repair of MultiBonnet® assemblies on packing.
active propane systems without interruption in gas service or
• This allows you to remove the upper packing nut, which contains
shutting off appliances downstream. This helps to prevent time
the o-rings, and replace it while the valve is fully open and gas
consuming relighting of pilots, special appointments, and call
service not interrupted.
backs.
• Cost of replacing the MultiBonnet® packing is only 1/3 as much as
replacing a complete bonnet assembly—not including time cost
savings, which can be substantial.

C5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ASME Multivalves® for Vapor Withdrawal
G8475R Series
Application
These Multivalves® are designed for use in single opening UL
ASME containers equipped with a 21⁄2” M. NPT riser. They ®

can be used with underground ASME containers up to 639


sq. ft. surface area, and above ground ASME containers up
to 192 sq. ft. surface area. A separate opening is required
for liquid withdrawal. The MultiBonnet® is standard on this
valve.
G8475R
Features
• The most complete Multivalve® assembly in the LP-Gas industry.

• Combines double back check filler valve, vapor equalizing valve


with excess flow, pressure relief valve with protective cap and
chain, service line shut-off valve, fixed liquid level gauge, “junior”
size float gauge flange opening and plugged pressure gauge
opening in one unit.

• Designed for installation of a 1/8” FNPT pressure gauge With the service valve closed the pressure port will be
or pressure gauge connection. The pressure test port will isolated from the container. This will allow a high pressure leak
communicate to the downstream side of the service valve. test to be conducted without disconnecting the pigtail from the
service valve.
• Double back check filler valve has filling capacities matched to the
high capacity pumps and meters on modern delivery trucks.

• Vapor equalizing valve with excess flow has increased capacity


matched to the filler valve.

• Internal threads accommodate 21⁄2” M. NPT riser pipe connection


and a 3⁄4” F. NPT connection for a customer furnished liquid baffle 5 5⁄8"
C tube. Approx. 8 1⁄8"
Approx.

• MultiBonnet® allows quick and easy repair of bonnet.


Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Valve Stems................................................................................ Brass 3⁄4 "
NPT thd.
2 1⁄2" NPT
30 " riser pipe
O-Rings..................................................................... Resilient Rubber for standard connection
Seat Disc (shut-off valve)........................................................... Nylon weight baffle pipe.
Length to suit tank
Seat Disc (other)....................................................... Resilient Rubber (furnished by customer).
Relief Spring................................................................ Stainless Steel
Approximate Filling Rate Liquid Flow, GPM
PRODU Pressure Drop Across Valve

10
O
G

CT

Part Number 10 PSIG 25 PSIG 50 PSIG 100 PSIG


RE

G8475RV
10

Y
NT

E
42 72 98 125
Y

AR A
WA R R
G8475RW
Ordering Information
Vapor Equalizing Fixed Pressure Relief Valve
Connection Float Liquid For use in
Dip
Part Container Service Filling UL Guage Level Flow Capacity conatiners
Tube
Number Connection Connection Connection Listed Flange Vent Part w/ surface are
Size Length Setting
Closing Opening Valve Number up to:
UL ASME
Flow Style

83 sq ft.
2020 1939 above ground
G8475RV M3131G SCFM, SCFM, 276 sq. ft.
air air under
4200
1 1/4” Fits ground
2 1/2” F. POL 1 3/4” CFH 250
M. “JUNIOR” Knurled 30”*
F. NPT (CGA 510) M. ACME @ 100 PSIG 192 sq. ft.
ACME size
PSIG above ground
3995
G8475RW MV3132G SCFM, n/a 639 sq. ft
air under
ground
*Dip tube not installed, may be cut by customer to desired length.

C6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ASME Multivalves® for Vapor Withdrawal
8593AR
Application
These Multivalves® provide vapor withdrawal and filling of ASME
containers. A separate pressure relief valve is required in addition to
this valve. The MultiBonnet® is standard on this valve.

Features
• Combines double back check filler valve, service valve, vapor
UL ®

equalizing valve with excess flow, fixed liquid level gauge and
plugged pressure gauge opening in one unit.

• Includes plugged, 1⁄4” F. NPT gauge boss.

• “Y” shape configuration allows for ease of operation with all valves
and gauges easily accessible at all times.

• Large 21⁄16” hex wrenching boss on center column provides ease of


installation in tank coupling.

• MultiBonnet® allows quick and easy repair of bonnet.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast 8593AR
Valve Stem................................................................................. Brass
O-Ring....................................................................... Resilient Rubber
Seat Disc (shut-off valve)........................................................... Nylon
Seat Discs (other)...................................................... Resilient Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Liquid Filling Rates


Approximate Filling Rate
Liquid Flow, GPM

Pressure Drop Across Valve


10 25 50 100
Part Number PSIG PSIG PSIG PSIG
8593AR16.0 42 72 98 125

Ordering Information
Vapor Equalizing Connection Fixed Liquid Dip
Part Container Service Filling Level Vent Tube For Use In Containers
Number Connection Connection Connection Connection Size UL Listed Closing Flow Valve Style Length w/ Surface Area Up To:
1½” F. POL 1¾” 1¼”
8593AR16.0 4200 CFH at 100 PSIG Knurled 16”* **
M. NPT (CGA 510) M. ACME M. ACME
*Dip tube not installed, may be cut by customer to desired length.
**Since these Multivalves® have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.

C7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
DOT Multivalve® for Liquid Withdrawal
8555DL
Application
These Multivalves® permit liquid withdrawal from DOT cylinders with
up to 100 lbs. propane capacity. They eliminate unnecessary cylinder
handling when servicing high volume loads and allow on-site filling
into the vapor space without interrupting gas service.

Features UL
®

• Incorporates service valve, high capacity filler valve with integral


back-check, fixed liquid level gauge, liquid withdrawal with excess
flow check and pressure relief valve in one single unit.

• CGA 555 service connection minimizes accidental connection to


vapor service systems.

• Furnished with 44” long, 1⁄2” O.D. brass liquid withdrawal tube.

• Liquid withdrawal tube incorporates a ball check excess flow valve


that opens by allowing vapor, not liquid, to equalize pressure.

• 11⁄8” wrenching flats.

Materials
8555DL
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast
Valve Stems................................................................................ Brass
O-Rings..................................................................... Resilient Rubber
Seat Disc (shut-off valve)........................................................... Nylon
C Seat Disc (others)...................................................... Resilient Rubber
Relief Spring................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Liquid Filling Rates


Approximate Filling Rate
Liquid Flow, GPM
Pressure Drop Across Valve
Part 10 25 50 100
Number PSIG PSIG PSIG PSIG
8555DL11.6 8 23 34 42

Ordering Information
For Use In
Fixed Liquid Dip Tube Liquid Pressure Cylinders Liquid Closing
Container Service Filling Level Vent Length w/ Withdrawal Tube Relief Valve w/Propane Flow
Part Number Connection Connection Connection Valve Style Deflector Length Setting Capacity Up To: (LP-Gas)***
¾” CGA 1¾” 375
8555DL11.6 Knurled 11.6” 44” 100 lbs. ** 1.7 GPM
M. NGT 555* M. ACME PSIG
* Use adapter 12982 to connect to pipe threads.
** Per CGA Pamphlet S-1.1.
*** To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use.

C8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
DOT Multivalves® for Vapor Withdrawal
6555R, 8555D and 8555R Series
Application
These Multivalves® permit vapor withdrawal. They allow for container
filling without interrupting gas service.

The 6555R Series is designed for ASME containers with up to 25 ft2


surface area or 60 gallons water capacity.

The 8555D and 8555R Series are designed for DOT cylinders with up UL
®
to 200 lbs. propane capacity.

Features
• Incorporates service valve, high capacity filler valve with integral
back-check, fixed liquid level gauge and pressure relief valve in
one single unit.

• Filler Valve is high capacity with integral back check.

• Heavy duty O-ring stem seal provides positive leak proof seal.

• Tapered nylon shut-off seat disc in fully confined seat ensures easy,
leak-free, positive shut-off.

• 11⁄8” wrenching flats.

• The MultiBonnet® option allows quick and easy repair of bonnet.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast C
Valve Stems................................................................................ Brass
O-Rings..................................................................... Resilient Rubber
Seat Disc (shut-off valve)........................................................... Nylon
Seat Disc (others)...................................................... Resilient Rubber
Relief Spring................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Liquid Filling Rates


Approximate Filling Rate
Liquid Flow, GPM
Pressure Drop Across Valve
Part 10 25 50 100
Number PSIG PSIG PSIG PSIG
8555D Series
8 23 34 42
8555R Series

Ordering Information
For Use In Pressure Relief Valve
Containers Dip Tube Fixed Liquid Flow Capacity*
Part with Size Up Length Container Service Filling Level Vent
Number Bonnet Style Application To: w/Deflector Connection Connection Connection Valve Style Setting UL Listing ASME
2
6555R10.6 MultiBonnet® 25 ft surface 10.6”
6555R11.6 MultiBonnet® ASME area or 60 11.6” 250 793 700
Containers gallons water PSIG SCFM, air SCFM, air
6555R12.0 MultiBonnet® capacity 12.0”
¾” F. POL 1¾”
8555D10.6 Standard Knurled
10.6” M. NGT (CGA 510) M. ACME
8555R10.6 MultiBonnet® DOT 200 lbs. 375
n/a n/a
8555D11.6 Standard Cylinders Propane ** PSIG
11.6”
8555R11.6 MultiBonnet®
*Per CGA Pamphlet S-1.1.

C9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
DOT and ASME Multivalves® for Vapor Withdrawal
6532, 6533, 6542 and 6543 Series
Application
These Multivalves® permit vapor withdrawal from ASME containers
up to 50 sq. ft. surface area and DOT containers up to 420 lbs.
propane capacity. They allow on-site cylinder filling without interrupting
gas service.

Features 6542 and 6543


• Incorporates high capacity filler valve with double back checks,
service valve, fixed liquid level gauge, pressure relief valve and
built-in baffle tube into one compact unit.

• Higher filling capacity is combined with back check protection by


placing the secondary back check at the bottom of the baffle tube,
creating a larger flow area through the body.

• Pre-drilled hole in 11⁄4” wrenching flat accepts a drive screw for


attaching relief cap and chain.

Features 6532 and 6533

• Similar but smaller than the 6542 and 6543, these are generally
used for replacement on existing containers with 3⁄4” NGT
openings.

• Secondary back check placed in the body of the valve to help PRODU

10
O
minimize reverse flow in the event the upper back check shears
UL
G

CT
RE

off or requires replacement. S ®


10

Y
NT
E
Y

AR A
WA R R
• The MultiBonnet® option allows quick and easy repair of bonnet.

C Liquid Filling Rates


Approximate Filling Rate -- Liquid Flow, GPM
Pressure Drop Across Valve
Materials
Part Number 10 PSIG 25 PSIG 50 PSIG 100 PSIG
6532A12.0/6532R12.0 11 16 23 28 Body............................................................................... Forged Brass
6542A12.0/6542R12.0 23 32 46 57
Handwheel............................................................ Aluminum Die Cast
Valve Stems................................................................................ Brass
6533A10.5/6533R10.5
11 16 23 28 O-Rings..................................................................... Resilient Rubber
6533A11.7/6533R11.7 Seat Disc (shut-off valve)........................................................... Nylon
6543A11.1/6543R11.1 Seat Disc (others)...................................................... Resilient Rubber
23 32 46 57
6543A11.7/6543R11.7 Relief Spring................................................................ Stainless Steel

Ordering Information
For Use In For Use In
Fixed Pressure Cylinders Containers
Liquid Dip Tube Relief w/Propane w/Surface
Part Container Service Filling Level Vent Length with Valve Capacity Area Up
Number Bonnet Style Application Connection Connection Connection Valve Style Deflector Setting Up To:** To:***
6532A12.0 Standard
¾” M. NGT 43 sq. ft.
6532R12.0 MultiBonnet® 250
ASME* 12.0” -
6542A12.0 Standard PSIG
1” M. NGT 53 sq ft.
6542R12.0 MultiBonnet®
6533A10.5 Standard
10.5”
6533R10.5 MultiBonnet® F. POL 1¾”
¾” M. NGT Knurled
6533A11.7 Standard (CGA 510) M. ACME
11.7”
6533R11.7 MultiBonnet® 375 420 lbs.
DOT -
6543A11.1 Standard PSIG Propane
11.1”
6543R11.1 MultiBonnet®
1” M. NGT
6543A11.7 Standard
11.7”
6543R11.7 MultiBonnet®
* UL rated flow capacities are: 6532A12.0-1180 SCFM/air, 6542A12.0-1530 SCFM/air.
** Per CGA Pamphlet S-1.1.
*** From NFPA, Appendix D.
C10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ASME Multivalves® for Vapor Withdrawal
7556R
Application
These compact Multivalves® are especially suited for vapor
withdrawal of ASME containers where compact groupings of
components are necessary. Separate filler valves and pressure relief
valves are required.

Features
• Combines service valve, vapor equalizing valve with excess flow,
fixed liquid level gauge and plugged pressure gauge opening in
one unit.
7556R
• Rugged, 1” wrenching boss on center column minimizes possible
damage during installation. UL ®

• Low profile design extends only 3” above the container boss,


allowing use of smaller domes.

• “Y” shape configuration allows for ease of operation with all valves New Style 7556R Series with ⅛” FNPT pressure test port.
and gauges easily accessible at all times.

• Designed for installation of a ⅛” FNPT pressure gauge or pressure gauge ⅛” F-NPT Pressure Test Port is isolated from the container when
connection. The pressure test port will communicate to the downstream the service valve is closed.
side of the service valve.

• MultiBonnet® allows quick and easy repair of bonnet.

Materials
Body............................................................................... Forged Brass
Handwheel............................................................ Aluminum Die Cast C
Valve Stems................................................................................ Brass
O-Rings..................................................................... Resilient Rubber
Seat Disc (shut-off valve)........................................................... Nylon
Seat Disc (others)...................................................... Resilient Rubber

With the service valve closed the pressure test port will be
isolated from the container. This will allow a high-pressure leak
test to be conducted without disconnecting the pigtail from the
service valve.

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Vapor Equalization Connection Fixed Liquid Dip For Use In
Container Service Level Vent Valve Tube Containers w/
Part Number Connection Connection Connection Size UL Listed Closing Flow Style Length Surface Area Up To:
F. POL
7556R12.0 ¾” M. NGT 1¼” M. ACME 4200 CFH @ 100 PSIG Knurled 12”** *
(CGA 510)
* Since these Multivalves® have no integral pressure relief valves, they can be used on any ASME container with an independant
relief device sufficent for that tank’s capacity.
** Other tube lengths available.

C11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Warning Notice
The following warning information, Part Number 903-500, is included
with each shipment of cylinder valves and service valves to the first
purchaser of the product from the factory.

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors.

Cross Reference by Part Number


6532A12.0.....................................................................................C10 6555R10.6............................................................................C9
6532R12.0.....................................................................................C10 6555R11.6.............................................................................C9
6533A10.5.....................................................................................C10 6555R12.0............................................................................C9
6533A11.7......................................................................................C10 7556R12.0..........................................................................C11
6533R10.5.....................................................................................C10 G8475RV................................................................................C6
6533R11.7......................................................................................C10 G8475RW...............................................................................C6
6542A12.0.....................................................................................C10 8555D10.6............................................................................C9
6542R12.0.....................................................................................C10 8555D11.6.............................................................................C9
6543A11.1......................................................................................C10 8555DL11.6..........................................................................C8
6543A11.7......................................................................................C10 8555R10.6............................................................................C9
6543R11.1......................................................................................C10 8555R11.6.............................................................................C9
6543R11.7......................................................................................C10 8593AR16.0..........................................................................C7

C12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section D
D D

Pressure Relief Valves


and Relief Valve Manifolds

D1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY Except as expressly set forth above, and subject to the limitation of
liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
LIMITED 10 YEAR WARRANTY OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
Engineered Controls International, Inc. (“ECII”) warrants to the original PARTICULAR PURPOSE, with respect to its products and parts,
purchasers the products and repair kits manufactured by it to be free whether used alone or in combination with others. ECII disclaims all
from defects in materials and workmanship under normal use and warranties not stated herein.
service for a period of 10 years from the date of manufacture. If within
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of LIMITATION OF LIABILITY
receipt , will repair, replace F.O.B. point of manufacture, or refund the
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of NOTICE TO USERS OF PRODUCTS
any and all claims of buyer arising out of such defect.
The Limited Warranty stated above is a factory warranty to the first
This warranty does not extend to any product or part that is not purchasers of ECII products. Since most users have purchased
installed and used continuously after installation in accordance with these products from ECII distributors, the user must within thirty (30)
ECII’s printed instructions, all applicable state and local regulations, days after the user’s discovery of what user believes is a defect,
and all applicable national standards, such as those promulgated by notify in writing and return the product to the distributor from whom
NFPA, DOT and ANSI. This warranty does not extend to any product he purchased the product/part. The distributor may or may not at
or part that has been damaged by accident, misuse, abuse, failure to the distributor’s option choose to submit the product/parts to ECII,
maintain, or neglect, nor does it extend to any product or part which pursuant to this Limited Warranty. Failure by buyer to give such
has been modified, altered, disassembled, or repaired in the field. written notice within thirty (30) days shall be deemed an absolute and
This warranty does not cover any cosmetic issues, such as scratches, unconditional waiver of buyer’s claim for such defects. Acceptance
dents, marring, fading of colors or discoloration. of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

Because of a policy of continuous product improvement, ECII

D reserves the right to change designs, materials or specifications


without notice.

D2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
D
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Cross Reference by Part Number........................................... D20
Duoport® Assemblies.............................................................. D17
General Information................................................................... D6
Hydrostatic Relief Valves......................................................... D16
Multiport™ Assemblies............................................................ D18
“Pop-Action” Relief Valves....................................................... D10
Saftey Warning.......................................................................... D4
Warnings................................................................................. D20

D3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Safety Warning — LP-Gas Pressure Relief Valves

Purpose

In its continuing quest for safety, Engineered Controls

! WARNING
International, Inc. is publishing safety warning bulletins
explaining the hazards associated with the use, misuse and
aging of ECII®/ RegO® Products. LP-Gas dealer managers
and service personnel must realize that the failure to exercise
the utmost care and attention in the installation, inspection
and maintenance of these products can result in personal
injury and property damage.

The National Fire Protection Association Pamphlet #58


What You Must Do:
“Storage and Handling of Liquefied Petroleum Gases” states:
“In the interests of safety, all persons employed in handling ● Read This Entire Warning
LP-Gases shall be trained in proper handling and operating
procedures.” ECII® Warning Bulletins are useful in training ● Install Properly
new employees and reminding older employees of potential
hazards. ● Inspect Regularly
This Warning Bulletin should be provided to all purchasers
of ECII® / RegO® Products and all personnel using or
servicing these products. Additional copies are available from
Engineered Controls International, Inc. and your Authorized
ECII®/ RegO® Products Distributor.

Scope

This bulletin applies to pressure relief valves installed


on stationary, portable and cargo containers and piping Warnings should be as brief as possible. If there is a simple
systems utilized with these containers. This bulletin is not warning, it is:
intended to be an exhaustive treatment of this subject and
does not cover all safety practices that should be followed Inspect pressure relief valves regularly. Replace unsafe or
in the installation and maintenance of LP-Gas systems. suspect valves immediately. Use common sense.
Each LP-Gas employee should be provided with a copy of
NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve
Inspection and Maintenance” as well as the NPGA “LP-Gas
Training Guidebooks” relating to this subject.

D4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Inspect Regularly
A pressure relief valve discharges when some extraordinary 4. Physical damage. Ice accumulations and improper
circumstance causes an over pressure condition in installation could cause mechanical damage. IF THERE ARE
the container. If a pressure relief valve is known to have ANY INDICATIONS OF DAMAGE, REPLACE THE VALVE.
discharged, the relief valve, as well as the entire system,
should be immediately and thoroughly inspected to determine
5. Tampering or readjustment. Pressure relief valves
the reason for the discharge. In the case of discharge due to
are factory set to discharge at specified pressures. IF
fire, the valve should be removed from service and replaced.
THERE ARE ANY INDICATIONS OF TAMPERING OR
READJUSTMENT, REPLACE THE VALVE.

Relief valves should be inspected each time the container is 6. Seat leakage. Check for leaks in the seating area using
filled but no less than once a year. If there is any doubt about a noncorrosive leak detection solution. REPLACE THE
the condition of the valve, it must be replaced. VALVE IF THERE IS ANY INDICATION OF LEAKAGE.
Never force a relief valve closed and continue to leave it
Eye protection must be worn when performing inspection on in service. This could result in damage to the valve and
relief valves under pressure. Never look directly into a relief possible rupture of the container or piping on which the
valve under pressure or place any part of your body where valve is installed.
the relief valve discharge could impact it. In some cases a
flashlight and a small mirror are suggested to assist when 7. Corrosion and contamination. REPLACE THE VALVE
making visual inspections. IF THERE ARE ANY SIGNS OF CORROSION OR
CONTAMINATION ON THE VALVE.
To Properly Inspect A Pressure Relief Valve, Check For:
1. A rain cap. Check protective cap located in valve or at end 8. Moisture, foreign particles or contaminants in the valve.
of pipeaway for a secure fit. Protective caps help protect Foreign material such as paint, tar or ice in relief valve
the relief valve against possible malfunction caused by parts can impair the proper functioning of the valves.
rain, sleet, snow, ice, sand, dirt , pebbles, insects, other Grease placed in the valve body may harden over time
debris and contamination. REPLACE DAMAGED OR or collect contaminants, thereby impairing the proper
MISSING CAPS AT ONCE AND KEEP A CAP IN PLACE operation of the relief valve. DO NOT PLACE GREASE
AT ALL TIMES IN THE VALVE BODY, REPLACE THE VALVE IF THERE
ARE ANY INDICATIONS OF MOISTURE OR FOREIGN
2. Open weep holes. Dirt, ice, paint and other foreign MATTER IN THE VALVE.
particles can prevent proper drainage from the valve
body. IF THE WEEP HOLES CANNOT BE CLEARED, 9. Corrosion or leakage at container connection. Check
REPLACE THE VALVE. container to valve connection with a non-corrosive leak D
detection solution. REPLACE THE VALVE IF THERE IS
3. Deterioration and corrosion on relief valve ANY INDICATION OF CORROSION OR LEAKAGE AT THE
spring. Exposure to high concentrations of water, CONNECTION BETWEEN THE VALVE AND CONTAINER.
salt, industrial pollutants, chemicals and roadway
contaminants could cause metal parts to fail. IF CAUTION: Never plug the outlet of a pressure relief valve. Any
THE COATING ON THE RELIEF VALVE SPRING IS device used to stop the flow of a properly operating pressure
CRACKED OR CHIPPED, REPLACE THE VALVE. relief valve that is venting an overfilled or overpressurized
container - raises serious safety concerns!

Replace Pressure Relief Valves In 10 Years Or Less


WARNING: Under normal conditions, the useful safe service
The safe useful life of pressure relief valves can vary greatly life of a pressure relief valve is 10 years from the original date
depending on the environment in which they live. of manufacture. However, the safe useful life of the valve
may be shortened and replacement required in less than 10
Relief valves are required to function under widely varying years depending on the environment in which the valve lives.
conditions. Corrosion, aging of the resilient seat disc and friction Inspection and maintenance of pressure relief valves is very
all proceed at different rates depending upon the nature of the important. Failure to properly inspect and maintain pressure relief
specific environment and application. Gas impurities, product valves could result in personal injuries or property damage.
misuse and improper installations can shorten the safe life of a
relief valve. For Additional Information Read:

Predicting the safe useful life of a relief valve obviously is not an 1. CGA Pamphlet S-1.1 Pressure Relief Standards - Cylinders, Section
exact science. The conditions to which the valve is subjected 9.1.1.
will vary widely and will determine its useful life. In matters of 2. ECII® Catalog L-500.
this kind, only basic guidelines can be suggested. For example,
the Compressed Gas Association Pamphlet S-1.1 Pressure 3. ECII® Warning # 8545-500.
Relief Device Standards — Cylinders, section 9.1.1 requires
all cylinders used in industrial motor fuel service to have the 4. NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve
cylinder’s pressure relief valves replaced by new or unused Inspection and Maintenance” and “LP-Gas Training Guidebooks”.
relief valves within twelve years of the date of manufacture
of cylinder and within each ten years thereafter. The LP-Gas 5. NFPA # 58, “Storage and Handling of Liquefied Petroleum Gases”.
dealer must observe and determine the safe useful life of relief
6. NFPA # 59, “LP-Gases at Utility Gas Plants”.
valves in his territory. The valve manufacturer can only make
recommendations for the continuing safety of the industry. 7. ANSI K61.1 Safety Requirements for Storage and Handling of
Anhydrous Ammonia.
D5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO® Pressure Relief Valves
Requirements for Pressure Relief Valves The reasons for this are two-fold:

Every container used for storing or hauling LP-Gas and anhydrous ● If the relief valve is called upon to open, the resulting
ammonia must be protected by a pressure relief valve. These discharge produces an increased vaporization of the
valves must guard against the development of hazardous product in the container with the result that the liquid cools
conditions which might be created by any of the following: to a certain extent and the vapor pressure drops. A reading
taken at this time would obviously not indicate what the
● Hydrostatic pressures due to overfilling or the trapping of pressure was when the relief valve opened.
liquid between two points.

● High pressures resulting from exposure of the container to ● The pressure gauges usually on most containers provide
excessive external heat. somewhat approximate readings and are not intended to
provide an indication of pressure sufficiently accurate to
● High pressures due to the use of incorrect fuel.
judge the setting of the relief valve.
● High pressures due to improper purging of the container.
Repair and Testing

Consult NFPA Pamphlet #58 for LP-Gas and ANSI #K61.1 for RegO® Pressure Relief Valves are tested and listed by
anhydrous ammonia, and/or any applicable regulations governing Underwriters Laboratories, Inc., in accordance with NFPA
the application and use of pressure relief valves. Pamphlet #58. Construction and performance of RegO®
Pressure Relief Valves are constantly checked at the factory
Operation of Pressure Relief Valves by U.L. inspectors. Therefore, testing of RegO® Pressure
Pressure relief valves are set and sealed by the manufacturer to function
at a specific “start-to-discharge” pressure in accordance with regulations.
Relief Valves in the field is not necessary.
This set pressure, marked on the relief valve, depends on the design
requirement of the container to be protected by the relief valve. If the Any pressure relief valve which shows evidence of leakage, other
container pressure reaches the start-to-discharge pressure, the relief valve improper operation or is suspect as to its performance must be
will open a slight amount as the seat disc begins to move slightly away replaced immediately using approved procedures.
from the seat. If the pressure continues to rise despite the initial discharge
through the relief valve, the seat disc will move to a full open position with Pipe-Away Adapters
a sudden “pop”. This sharp popping sound is from which the term “pop-
action” is derived. Pipe-away adapters are available for most RegO® Pressure
D Whether the relief valve opens a slight amount or pops wide open, it will
Relief Valves, where it is required or desirable to pipe the
discharge above or away from the container. Each adapter
start to close if the pressure in the container diminishes. After the pressure is designed to sever if excessive stress is applied to the vent
has decreased sufficiently, the relief valve spring will force the seat disc
piping – thus leaving the relief valve fully operative.
against the seat tightly enough to prevent any further escape of product.
The pressure at which the valve closes tightly is referred to as the “re-seal”
or “blow-down” pressure. Generally, the re-seal pressure will be lower than Weep hole deflectors are available on larger relief valves.
the start-to-discharge [Link] re-seal pressure can be, and in most These deflectors provide protection against flame impinging
cases is, adversely affected by the presence of dirt, rust, scale or other on adjacent containers which could occur from ignition of
foreign particles lodging between the seat and disc. They interfere with LP-Gas escaping through the relief valve drain hole when the
the proper mating of the seat and disc and the pressure in the container valve is discharging.
will usually have to decrease to a lower pressure before the spring force
embeds foreign particles into the resilient seat disc material and seals Selection of RegO® Pressure Relief Valves For ASME
leak-tight. The degree by which the presence of dirt decreases the re-seal Containers
pressure, is, of course, dependent on the size of the interfering particles.
The rate of discharge required for a given container is
Once particles have been trapped between the disc and seat, the start-
to-discharge pressure is also affected. For example, the pressure relief
determined by the calculation of the surface area of the
valve will start-to-discharge at some pressure lower than its original start- container as shown in “Chart A” for LP-Gas and “Chart B” for
to-discharge pressure. Again, the pressure at which the valve will start to anhydrous ammonia. See page D9.
discharge is dependent on the size of the foreign particles.
Setting - The set pressure of a pressure relief valve depends
In the case of a pressure relief valve that has opened very slightly due upon the design pressure of the container. Refer to NFPA
to a pressure beyond its start-to-discharge setting, the chances of Pamphlet #58 for more information.
foreign material lodging between the seat and disc is negligible although
the possibility is always present. If the relief valve continues to leak at
Selection of RegO® Pressure Relief Valves for DOT
pressures below its start-to-discharge setting it must be replaced.
Containers
Relief valves which have “popped” wide open must also be
checked for foreign material lodged between the seat and disc, To determine the proper relief valve required for a given
as well as for proper reseating of the seat and disc. Continued DOT container, refer to the information shown with each
leakage at pressures below the start-to-discharge setting indicate pressure relief valve in the catalog. This information will give
the relief valve must be replaced. the maximum size (pounds water capacity) DOT container for
which the relief valve has been approved.
The pressure at which a pressure relief valve will start to discharge
should never be judged by the reading of the pressure gauge Setting - The standard relief valve setting for use on DOT
normally furnished on the container. cylinders is 375 PSIG.
D6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
RegO® Pressure Relief Valves
Ordering RegO® Pressure Relief Valves Part Number Explanation

When ordering RegO® Pressure Relief Valves, be sure you are Products carrying an “A” or “AA” prefix contain no brass parts and
certain that it will sufficiently protect the container as specified in are suitable for NH3. Hydrostatic relief valves carrying an “SS”
the forewording information, NFPA Pamphlet #58 and any other prefix are of stainless steel construction and are suitable for use
applicable standards or specifications. with NH3. The products are also suitable for use with LP-Gas
service except relief valves carrying an “AA” prefix. These are
All adapters, protective caps and deflectors must be ordered of partial aluminum construction and are listed by U.L. for NH3
separately, unless specified otherwise. service only.

Safety Information - Relief Valves Don’t Last Forever

RegO® Relief Valve for lift truck containers

The internal spring is protected from external


contamination but the other external parts must
be protected with a cap. Circular rubber seat
disc ring seats on brass shoulder approximately
3⁄64” wide.

Relief valves, over the years, may not function properly


This article was prepared by the engineers of RegO® products, in several ways: D
after technical consultation with valve manufacturers and other
industry sources. Its purpose is to alert and remind the LP-Gas ● They may leak at pressures below the set pressure.
industry of the importance of proper maintenance of pressure
relief valves. It applies most particularly to separate relief valves ● They may open and fail to properly reseat.
with emphasis on lift truck and motor fuel containers where the ● They may open at higher than the set pressure.
hazards of contamination are greatest.
These failures to function properly are due primarily to
four “environmental’’ conditions:
Since the beginning of our industry, manufacturers of equipment
and distributors of LP-Gas have worked diligently to provide a safe 1. Corrosion of metal parts (particularly springs) which result
environment for employees and consumers. The history of the in the component parts failing to perform.
industry testifies to the success of their efforts.
2. Deterioration of the synthetic rubber seat disc material.
But the industry is now entering its sixth decade and equipment 3. Clogging or “cementing” of the movable relief valve
installed years ago is failing because of age. Every year, additional components so that their movement is restricted.
equipment will fail unless it is replaced. Pressure relief valves are
no exception. The valve manufacturers and LP-Gas dealers are 4. Debris on the valve seat after the relief valve opens,
naturally concerned about this situation. effectively preventing the valve from reseating.
Corrosion is caused by water, corrosive atmospheres of salt and
Causes of Relief Valve Failure industrial pollutants, chemicals, and roadway contaminants. High
A relief valve is designed to have a safe useful life of many years, concentrations can attack the metal parts vigorously. No suitable
but that life will vary greatly depending on the environment in metals are totally resistant to such corrosion.
which it “lives.” To attempt to estimate the safe useful life of a relief
valve and the effect of environment on its performance, a brief Synthetic rubber and seat disc materials can also be attacked by
discussion of the materials used and the nature of its performance impurities in the gas and corrosive atmospheres, particularly those
should be helpful. with sulphur dioxide. There are no suitable rubber materials which
resist all contaminants.
Relief valve bodies are generally made of brass or steel. Springs
are made from various spring wires which are plated or painted, “Cementing” of relief valve parts has been caused by normal
or made of stainless steel. Valve seat discs are made of synthetic industrial atmospheres containing particles of dirt, iron oxide,
rubber compounds which will remain serviceable in an atmosphere metal chips, etc. combined with water, oil, or grease. Ice collecting
of LP-Gas. Relief valve stems, guides, etc. are generally made in recessed valves could cause relief valves to fail to open. Paint
from brass or stainless steel. and tar in relief valves also cause failure to function properly.
D7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Safety Information - Relief Valves Don’t Last Forever
Debris on valve seats which prevents reseating can occur Use of Protective Caps
whenever the valve collects material in the relief valve opening
which is not blown out when the relief valve opens.
Many of the problems that cause inoperative relief valves could be
prevented if proper protective caps were kept in place at all times.
Inspection of Relief Valves

Unfortunately many of the above problems may not be easily Collection of debris would be prevented. Contamination caused by
observed because of the compact nature of some relief valve corrosive atmospheres would be reduced. Water collection in the
designs. valves would be eliminated. Relief valves protected with caps
from the time of installation in the container would obviously have
a much longer safe useful life, but they still should be replaced at
A casual visual inspection of a relief valve may not necessarily disclose some time because of the gradual deterioration of the rubber seat
a potential hazard. On the other hand, a visual inspection will often disc due to age alone.
disclose leakage, corrosion, damage, plugging and contamination.

NFPA 58 requires that protective caps must be kept in place as


If additional light is required, a flashlight should be used. a protective cover on some relief valves. This is a mandatory
requirement on several types of relief valves. The fact that use of
caps may make inspection more time consuming should not be
If there is any doubt about the condition of the valve, or if there is a
viewed as a reason for either not using the caps, or not making
suspicion that the valve has not been protected by a cap for some
time, it should be replaced before refilling the container. required periodic inspections.

In the event a relief valve has been used without the required
cap, the relief valve should be thoroughly inspected and the
Eye protection must be used when examining relief valves under required cap placed on the relief valve. If damage is noted to
pressure.
the relief valve, it should be replaced and the replacement valve
Smaller Relief Valves should be capped. Relief valves with pipe-away adapters or
deflectors used on lift truck containers have been found choked
The industry’s requirement for a small full-flow safety relief valve with debris. Inspection of relief valves with deflectors can only be
challenged design engineers some years ago: accomplished by removing the deflector.

D ● The valve must be leakproof before operating and must


Similarly, larger relief valves with vent stacks have been found
choked with debris and water. Valves have failed because springs
reseat leakproof each time after each operation. The only
rusted through. The weep hole was plugged. It was obvious
known satisfactory seat disc materials to accomplish this
that the relief valves had not been inspected in many years.
have been special synthetic rubber compounds.
These conditions must be alleviated by periodic inspections and
replacement of relief valves as needed.
● Valve discharge settings are relatively high and require
high spring loads to keep the valve closed. Summary Recommendations
Predicting the safe useful life of a relief valve is obviously not an
● Because of the small interior diameter of the valve, the exact science. The conditions to which the valve is subjected
round metal seating area is small. will vary widely and will largely control its life. In matters of this
All of these parameters may result in the development of a kind, only basic guidelines can be suggested. The LP-Gas
significant indentation in the rubber seat disc after some years. dealer must observe and determine the safe useful life of relief
The seat disc may have a tendency to cling to the metal seat. This valves in his territory. The valve manufacturers can only make
may result in the relief valve not opening at the set pressure as the recommendations for the continuing safety of the industry:
seat disc ages.
1. Make sure proper protective caps are in place at all times.
Test have been conducted on small LP-Gas relief valves of all the Do not release a container for service or fill a container
U.S. valve manufacturers. Valves over 10 years old were removed unless it has a protective cap in place.
from service and tested to determine at what pressure the valves
2. Replace relief valves periodically, at least every 10 years.
discharged. In many of the valves, the pressure required to open
Every relief valve has the month and year of manufacture
the valve exceeded the set pressure. stamped on the valve. This is most particularly true of
small separate relief valves.
Because of the critical importance of proper functioning of relief valves,
common sense and basic safety practice dictate that small relief 3. Carefully inspect valves each time before the container is
valves should be replaced in about 10 years. filled. Replace valves showing any signs of contamination,
corrosion, damage, plugging, leakage, or any other
problem. Eye protection must be used when examining
Some larger relief valves on bulk storage tanks can be replaced
relief valves under pressure.
with rebuilt valves obtained from the manufacturers. Small relief
valves cannot be rebuilt economically, thus, new valves are
required. Most LP-Gas dealers find it impractical and costly to test
relief valves and field repairing of relief valves is not sanctioned by
the manufacturers, Underwriter’s Laboratories, or ASME.
D8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Chart A — Minimum Required Rate of Discharge for LP-Gas Pressure Relief Valves Used on
ASME Containers Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-to-discharge
pressure for pressure relief valves to be used on containers other than those constructed in accordance with Interstate
From NFPA Pamphlet #58, Appendix D (1986). Commerce Commission specification.
Surface Surface Surface Surface Surface Surface
Surface Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate
Area Sq. Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air
20 or less 626 85 2050 150 3260 230 4630 360 6690 850 13540 1500 21570
25 751 90 2150 155 3350 240 4800 370 6840 900 14190 1550 22160
30 872 95 2240 160 3440 250 4960 380 7000 950 14830 1600 22740
35 990 100 2340 165 3530 260 5130 390 7150 1000 15470 1650 23320
40 1100 105 2440 170 3620 270 5290 400 7300 1050 16100 1700 23900
45 1220 110 2530 175 3700 280 5450 450 8040 1100 16720 1750 24470
50 1330 115 2630 180 3790 290 5610 500 8760 1150 17350 1800 25050
55 1430 120 2720 185 3880 300 5760 550 9470 1200 17960 1850 25620
60 1540 125 2810 190 3960 310 5920 600 10170 1250 18570 1900 26180
65 1640 130 2900 195 4050 320 6080 650 10860 1300 19180 1950 26750
70 1750 135 2990 200 4130 330 6230 700 11550 1350 19780 2000 27310
75 1850 140 3080 210 4300 340 6390 750 12220 1400 20380
80 1950 145 3170 220 4470 350 6540 800 12880 1450 20980

Surface area =Total outside surface area of container in square feet. Flow Rate SCFM Air = Required flow capacity in cubic feet per minute
When the surface area is not stamped on the name plate or when the of air at standard conditions, 60ºF. and atmospheric pressure (14.7 psia).
marking is not legible, the area can be calculated by using one of the The rate of discharge may be interpolated for intermediate values of
following formulas: surface area. For containers with total outside surface area greater than
1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = 2000 square feet, the required flow rate can be calculated using the
overall length (ft.) x outside diameter (ft.) x 3.1416. formula, Flow Rate—SCFM Air = 53.632 A0.82. Where A = total outside
surface area of the container in square feet.
2. Cylindrical container with semi-ellipsoidal heads. Area (in sq. ft.) =
overall length (ft.) + .3 outside diameter (ft.) x outside diameter (ft.) x
3.1416.
3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x
3.1416.

D
Chart B — Minimum Required Rate of Discharge for Anhydrous Ammonia Pressure Relief
Valves Used on ASME Containers
Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-
From ANSI K61.1-1981, Appendix A (1981). to-discharge pressure for pressure relief valves to be used on containers other than those constructed in
accordance with United States Department of Transportation cylinder specifications.

Surface Surface Surface Surface Surface Surface


Surface Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate
Area Sq. Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air
20 258 95 925 170 1500 290 2320 600 4200 1350 8160 2100 11720
25 310 100 965 175 1530 300 2380 650 4480 1400 8410 2150 11950
30 360 105 1010 180 1570 310 2450 700 4760 1450 8650 2200 12180
35 408 110 1050 185 1600 320 2510 750 5040 1500 8900 2250 12400
40 455 115 1090 190 1640 330 2570 800 5300 1550 9140 2300 12630
45 501 120 1120 195 1670 340 2640 850 5590 1600 9380 2350 12850
50 547 125 1160 200 1710 350 2700 900 5850 1650 9620 2400 13080
55 591 130 1200 210 1780 360 2760 950 6120 1700 9860 2450 13300
60 635 135 1240 220 1850 370 2830 1000 6380 1750 10090 2500 13520
65 678 140 1280 230 1920 380 2890 1050 6640 1800 10330
70 720 145 1310 240 1980 390 2950 1100 6900 1850 10560
75 762 150 1350 250 2050 400 3010 1150 7160 1900 10800
80 804 155 1390 260 2120 450 3320 1200 7410 1950 11030
85 845 160 1420 270 2180 500 3620 1250 7660 2000 11260
90 885 165 1460 280 2250 550 3910 1300 7910 2050 11490

Surface area = Total outside surface area of container in square feet. Flow Rate SCFM Air = Required flow capacity in cubic feet per minute of
When the surface area is not stamped on the name plate or when the air at standard conditions, 60°F. and atmospheric pressure (14.7 psia).
marking is not legible, the area can be calculated by using one of the The rate of discharge may be interpolated for intermediate values of
following formulas: surface area. For containers with total outside surface area greater than
1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = overall 2,500 square feet, the required flow rate can be calculated using the
length (ft.) x outside diameter (ft.) x 3.146. formula, Flow Rate—SCFM Air = 22.11 A0.82 where A = outside surface area
of the container in square feet.
2. Cylindrical container with other than hemispherical heads. Area (in sq.
ft.) = overall length (ft.) + .3 outside diameter (ft.) x outside diameter (ft.) Conversion Factor
x 3.1416. ft2 x 0.092 903 = m2
3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x SCFM x 0.028 317 = m3/min
3.1416. ft x 0.304 8 =m

D9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
“Pop-Action” Pressure Relief Valves
General Information Relief Valves in this catalog are only intended
The “Pop-Action” design permits the RegO® Pressure Relief Valve to open slightly to relieve
for use in LP-Gas or anhydrous ammonia
moderately excessive pressure in the container. When pressure increases beyond a predetermined
service. Do not use any other service
point, the valve is designed to “pop” open to its full discharge capacity, reducing excess pressure
commodity. If you have an application other
quickly. This is a distinct advantage over ordinary valves which open gradually over their entire
than conventional LP-Gas or anhydrous
range, allowing excessive pressure to develop before the relief valve is fully open. All RegO® internal,
ammonia service, contact Engineered
semiinternal, and external relief valves incorporate this “Pop-Action” design.
Controls International, Inc before proceeding.

Fully Internal “Pop-Action” Pressure Relief Valves for


Transports and Delivery Trucks A8434 and A8436 Series

Application
Designed specifically for use as a primary relief valve in ASME
transports and delivery trucks with 2” and 3” NPT couplings.

Features
• Low profile design assures maximum protection against sheering
or distortion.

• All functioning parts are located below the level of the container
connection to reduce the possibility of damage or tampering.

• Longer spring size designed to minimize stress cracking in service.

D • Use of two different materials for stem and guide minimizes the
possibility of stem seizure which may occur when similar materials
are used.

• Internal octagonal wrenching broach assures easy installation and


removal.
UL
• ASME approved for use with LP-Gas and anhydrous ammonia. ®

A8434-SERIES

Materials
PRODU
Body............................................................................ Stainless Steel

10
O
G

Spring.......................................................................... Stainless Steel


CT
RE

Stem............................................................................ Stainless Steel


S

Stem Bushing............................................... 17 - 4PH Stainless Steel


10

Y
NT

Seat Disc................................................... Resilient Synthetic Rubber E


Y

AR A
WA R R

Ordering Information
Start To A B C UL
Part Discharge Container Overall Height Height Above (At 120% of Set ASME (At 120% Suitable for Tanks with Protective Cap
Number Setting PSIG Connection (Approx.) Coupling (Approx.) Pressure) of Set Pressure) Surface Area Up To:* (Included)
A8434N 265 3659
2” M. NPT 9 1/16” ½” 3700 175 Sq. Ft. A8434-11B
A8434G 250 3456
A8436N 265 9839
3” M. NPT 17 ⅞” ¾” 10210 602 Sq. Ft. A8436-11B
A8436G 250 9598
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.

D10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Fully Internal “Pop-Action” Pressure Relief Valves for
Motor Fuel Containers 8543 and 8544 Series
Application
8543 Series relief valves are designed for use as a primary relief
valve in larger ASME motor fuel containers such as on buses, trucks
and construction equipment.

8544 Series relief valves are designed for use as a primary relief
valve in smaller ASME and DOT motor fuel containers such as on
tractors, lift trucks, cars and taxicabs.

Features
• Assure minimum product loss due to “pop-action” design. 7543-10
7544-11A
• Recessed design minimizes possibility of damage and tampering.

• All are threaded to accept RegO® Pipeaway Adapters that permit


the addition of a discharge hose or piping.

• ASME rated for use with LP-Gas (except 8544K which meets DOT
requirements). D

• Specify RegO® Relief Valves on all your original equipment motor


fuel container purchases for reliable performance.
C

Materials A
Body........................................................................................... Brass
UL D
Spring (8543)............................................................... Stainless Steel ®

Spring (8544).................................................................. Coated Steel B


Seat Disc................................................................... Resilient Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

8544

Ordering Information
Flow Capacity SCFM/Air****
A B C D Accessories
Start To Container Overall Height Above Hex UL ASME Protective
Part Container Discharge Connection Height Coupling Wrenching (At 120% of (At 120% of Cap Pipeaway
Number Type Setting PSIG M. NPT (Approx.) (Approx.) Section Set Pressure) Set Pressure) (Included) Adapter
8544G 1” 1 5 16 ” 1020 936 7544-41 7544-11A*
250
8543G 1¼” 111 16 ” 1465 1400 7543-40C 7543-10**
ASME 5
8544T 1” 5 7
16 ” ⅞” 1 16 ” 1282 1158 7544-41 7544-11A
312
8543T 1¼” 1 16 ”
11
1990 1731 7543-40C 7543-10**
8544K DOT/ASME 375 1” 1 5 16 ” 1545*** - 7544-41 7544-11A

* 1” M. NPT outlet connection.


** 11⁄4” M. NPT outlet connection.
*** Rating also applies to DOT requirements.
**** Flow rates shown are for bare relief valves. Adapters and pipeaway will reduce flow as discussed in forewording information.

D11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Fully Internal “Pop-Action” Pressure Relief Valve
for DOT Fork Lift Cylinders 8545AK
Application
Designed specifically for use as a primary relief valve on forklift
cylinders, the 8545AK reduces the possibility of improper functioning
of the relief mechanism due to foreign material build up. All guides,
springs, stem and adjusting components are located inside the
cylinder - removed from the direct exposure of foreign materials and
debris from the atmosphere.

NFPA Pamphlet #58 requires that:


“All containers used in industrial truck (including forklift truck cylinders)
service shall have the container pressure relief valve replaced by a 7545-12 90° Adapter 7545-14 45˚ Adapter
new or unused valve within 12 years of the date of manufacture of the
container and each 10 years thereafter.”

Features UL
®

• Positive stop in the upper body protects against improper insertion


of a pipeaway adapter that might interfere with proper operation
of the relief valve.

• Internal stem guide eliminates the need for a close fit between the
body and poppet, which lessens the chance of clogging due to
foreign material.

• Single piece cold-headed stem provides more accurate positioning


of working parts for more consistent operation and precise
adjustment.

• Two different deflector adapters and a protective cap are available


as accessories to provide complete protection.

D • “Pop-action” design keeps product loss at a minimum.

• Request RegO® Relief Valves on all your original equipment forklift


cylinders for reliable performance.

Materials
Body........................................................................................... Brass
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel
Poppet........................................................................................ Brass
Guide.......................................................................................... Brass
Seat Disc................................................................... Resilient Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Accessories (Order Separately)
Flow Capacity SCFM/Air**
Deflectors***
Part Container Start To Discharge Container Protective
Number Type Setting PSIG Connection M. NPT (ECII® Rated at 480 PSIG Cap 45° Elbow 90° Elbow
8545AK Dot 375 ¾” 400* 7545-40 7545-14 7545-12

* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders.
Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas.
** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information.
*** Order protective cap #8545-41 or 7545-40.

D12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Semi-Internal “Pop-Action” Pressure Relief Valves for ASME
Containers 7583, 8684 and 8685 Series
Application
Designed for use as a primary relief valve on ASME containers such UL
®

as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists


containers systems on which these types of valves are mounted
outside the hood without additional protection, if mounted near the
hood and fitted with a protective cap.

Features PRODU

10
O

CT
RE
• Constructed of non-corrosive materials.

S
10

Y
NT
E
• “Pop-action” design keeps product loss at a minimum.

Y
AR A
WA R R

• ASME rated for use with LP-Gas.

• Request RegO® Relief Valves on all your original equipment ASME Materials
containers for reliable performance.
Body........................................................................................... Brass
Spring.......................................................................................... Steel
Stem............................................................................ Stainless Steel
Seat Disc................................................................... Resilient Rubber
Ordering Information
Flow Capacity SCFM/Air
A B C D
Start To Container Overall Height Above Wrench Suitable for
Part Discharge Connection Height Coupling Hex UL (At 120% of Set ASME (At 120% of Tanks w/Surface Protective
Number Setting PSIG M. NPT (Approx.) (Approx.) Section Pressure) Set Pressure) Area Up To:* Cap (Included)
7583G ¾” 8 316” 1716 ” 1¾” 1980 1806 80 Sq. Ft. 7583-40X
8684G 250 1” 9 3 8” 1916” 1 7 8” 2620 2565 113 Sq. Ft. 8684-40
8685G 1¼” 11116 ” 11116” 2 3 8”
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.
4385 4035 212 Sq. Ft. 7585-40X
D
Application
Designed especially for use as a primary relief valve on large
stationary storage containers, these low profile relief valves are
generally mounted in half couplings. However, they are designed so
UL ®

that the inlet ports clear the bottom of a full 2” coupling. This assures
that the relief valve should always be capable of maximum flow
under emergency conditions.

Features PRODU

10
O
G

CT
RE

• High capacity, low turbulence design has a maximum guiding area


providing for dependable shut-off after opening.
10

Y
NT

E
Y

AR A
WA R R
• Built-in spring stop limits the rise of the seat in full open position
and prevents the spring from going “solid”.

• External 3” NPT threaded body allows easy attachment of vent


stacks. Optional pipeaway adapter has break-off groove to
prevent damage to the relief valve should piping be stressed by
damaging winds.
Materials
• “Pop-Action” design keeps product loss at a minimum.
Body........................................................................................... Brass
• No guiding projections around the seat disc retainer to bind and Spring.......................................................................................... Steel
hinder opening of valve if body is damaged. Stem............................................................................ Stainless Steel
Seat Disc................................................................... Resilient Rubber
Ordering Information
Flow Capacity SCFM/Air* Accessories
Part Start To Discharge Container Connection UL (At 120% of ASME (At 120% of Suitable for Tanks w/ Pipeaway
Number Setting PSIG M. NPT Set Pressure) Set Pressure) Surface Area Up To:** Protective Cap Adapter
7534B 125 6,025 - 319 Sq. Ft.
2” 7534-40 7534-20***
7534G 250 11,675 10,422 708 Sq. Ft.
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the forewording information.
** Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME—whichever is larger.
*** 3” F. NPT outlet connection.

D13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
External “Pop-Action” Pressure Relief Valves for ASME Containers and Bulk Plant
Installations AA3126, AA3130, 3131, 3132, 3133, 3135, AA3135, and A3149 Series

Application
3135-10
Designed for use as a primary relief valve on ASME above ground
and underground containers, bulk plant installations and skid tanks.
The 3131 Series may also be used as a primary or secondary
relief valve on DOT cylinders, or as a hydrostatic relief valve. All
working components of these relief valves are outside the container
connection, so the valves must be protected from physical damage.

Features
UL
• “Pop-action” design keeps product loss at a minimum. ®

• Relief valve designed to automatically reseat firmly after discharge. 3135 A3149

• Resilient seat disc provides “bubble-tight” seal.

• 3149 relief valves incorporate integral pipeaway adapter with break


off groove that protects the valve from piping stress damage.

• Optional pipeaway adapters have grooves that will break off to


protect the relief valve from damage should excess stress be
applied to the piping. 3132-10
• 3149 relief valves include weep hole deflectors, installed to guard
against flame impingment on adjacent containers.

• Most are ASME rated for use with LP-Gas and anhydrous
ammonia.

AA3135 W3132G
Materials
D Description 3131, 3132, 3133, 3135 AA3126 AA3130 AA3135 A3149 PRODU

10
O
Body Brass Aluminum Rod* Upper Cold Rolled Steel Lower Ductile Iron

CT
RE

S
Liner None Stainless Steel

10

Y
Spring Guide Brass Aluminum Stainless Steel

NT
E

Y
AR A
Spring Corrosion Resisant Steel Stainless Steel Stainless Steel or Coated Steel WA R R

Seat Disc Resilient Synthetic Rubber

Ordering Information
Flow Capacity SCFM/Air (a) Accessories
Start To A B C UL Suitable
Discharge Container Overall Wrench (At 120% ASME for Tanks
Setting Connection Height Hex of Set (At 120% of w/Surface Area Weep Hole
Part Number PSIG M. NPT (Approx.) Section Pressure) Set Pressure) Up To: (e) Protective Cap Part Number Outlet Size Deflector
AA3126L030 30 ½” 2⅜” ⅞” (b) - - 7545-40 AA3126-10 ½” M. NPT -
A3149L050 50 2600(c) - 113 Sq. Ft.
2½” 10½” 4⅛” 3149-40 (h) Included (j)
A3149L200 200 8770 (c) - 500 Sq. Ft.
AA3126L250 ½” 2⅜” ⅞” 277 (c) - 23 Sq. Ft. (f) 7545-40 AA3126-10 ½” M. NPT
3131G 7 2060 1939 85 Sq. Ft. 3131-40 (g) - -
¾” 3 16 ” 1¾”
AA3130UA250 2045 1838 249 Sq. Ft. (f) AA3130-40P AA3131-10 1” F. NPT
W3132G 1” 3340 - 154 Sq. Ft. 3132-10 1¼” F. NPT
3132G 1 4130 - 200 Sq. Ft. -
6 32 ” 2⅜” 3132-54 (g)
T3132G 3790 - 180 Sq. Ft. 3132-10 1¼” F. NPT
250
MV3132G 3995 - 190 Sq. Ft. -
1¼” 3133-11
3135G 5
21
32 ” 5770 - 300 Sq. Ft. 3135-54 (g) 3135-10
11
2 ”
16
AA3135-0PR
AA3135UA250 6 13 32” 6430 6341 1010 Sq. Ft. (f) AA3135-10 2” F. NPT
15
3133G 1½” 5 16 ” 3⅛” 6080 - 320 Sq. Ft. 3133-40 (g) 3133-10
A3149G 2½” 10½” 4⅛” 10390 9153 613 Sq. Ft. 3149-40 (h) Included (j)
7
AA3130UA265 ¾” 3 16 ” 1¾” 2125 1912 261 Sq. Ft. (f) AA3130-40P AA3131-10 1” F. NPT -
265 AA3135-
AA3135UA265
11
1¼” 6 13 32” 2 ”
16 6615 6703 1045 Sq. Ft. (f) AA3135-10 2” F. NPT 3133-11
40PR
AA3126L312 312 ½” 2⅜” ⅞” 330 (c) - 27 Sq. Ft. (f) 7545-40 AA3126-10 ½” M. NPT -
(a) Flow rates shown are for bare relief valves. Adapters and pipeaways will (f) Per ANSI K61.1-1972, Appendix A.
reduce flow as discussed in forewording information. (g) Cap supplied with chain.
(b) Not UL or ASME rated. .059 square inch effective area. (h) Outlet 31⁄2-8N (F) thread, will accept 3” M. NPT pipe thread.
(c) Not UL or ASME rated. ECII® rated at 120% of set pressure. (j) Weep hole deflector is Part No. A3134-11B.

(e) Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME
flow rating—whichever is larger.
D14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
External “Pop-Action” Supplementary Pressure Relief Valves for
Small ASME Containers and DOT Cylinders 3127 and 3129 Series

Application
Designed for use as a supplementary relief valve on small ASME
above ground and underground containers. They may also be used 3129-10 Pipe Away Adapter
as a primary or secondary relief device on DOT cylinders, or as
hydrostatic relief valves.

All working components of these relief valves are outside the


container connection, so the valves must be protected from physical
damage.
UL
Features
®

3127 Series
• “Pop-action” design keeps product loss at a minimum.

• Relief valve designed to automatically reseat firmly after discharge.

• Resilient seat disc provides a “bubble-tight” seal.

Materials
Body........................................................................................... Brass
Spring.......................................................................... Stainless Steel
Seat Disc................................................................... Resilient Rubber

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Accessories
Flow Capacity SCFM/
Air Pipeaway Adapter
Start To A B C UL
Discharge Container Overall Wrench (At 120% ECII® Rated Suitable for
Container Setting Connection Height Hex of Set at 480 Tanks w/Surface Protective
Part Number Type PSIG M. NPT (Approx.) Section Pressure) PSIG*** Area Up To:* Cap Part Number Outlet Size
3127G ¼” 1 31 32” ⅞” 295 -
ASME 250 - -
3129G ½” 2 19 32 ” 1⅛” 465 3129-10 ½” F. NPT
7545-40
3127K ¼” 1 31 32 ” ⅞” 450 100 lbs./Propane -
DOT 375 -
3129K ½” 219 32 ” 1⅛” 780 200 lbs./Propane 3129-10 ½” F. NPT

* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information.
** Not UL or ASME rated. ECII® rated at 480 PSIG.
*** Meets DOT requirements.

D15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
External Hydrostatic Relief Valves 3125, 3127, 3129, SS8001,
SS8002, SS8021 and SS8022 Series
Application
Designed especially for the protection of piping and shut-off valves
where there is a possibility of trapping liquid LP-Gas or anhydrous
ammonia. They may be installed in pipelines and hoses located
between shut-off valves or in the side boss of RegO® shut-off
valves.

Features
• Relief valve designed to automatically reseat firmly after discharge.

• Resilient seat disc provides a “bubble-tight” seal.

• Available in both brass and stainless steel.

• Available in configurations that permit direct attachment of vent


piping when required.

Materials
Body (3125, 3127, 3129)............................................................ Brass
Body (SS8001, SS8002, SS8021, SS8022)................ Stainless Steel
Spring.......................................................................... Stainless Steel
Seat Disc................................................................... Resilient Rubber
3125 Series (.161 Orifice)
3127 Series (.274 Orifice) UL PRODU
Ordering Information
®

10
O
3129 Series (.386)

CT
RE

S
Accessories

10

Y
NT
E

Y
AR A
A C WA R R
Pipeaway
Start To Container B Wrench
Part Discharge Valve Body Connection Height Hex Protective Adapter or
Number Setting PSIG Material M. NPT (Approx.) Section Cap Threads
SS8001G ¼” 11
16 ”
⅞” -
SS8002G Stainless ½” ⅞”
-
SS8021G Steel ¼” 11
16 ” ¼” NPSM Thrds
250 1⅜”
SS8022G ½” ⅜” NPT Thrds
⅞”
3127G ¼” 131 32” -
3129G ½” 219 32” 1⅛” 3129-10*
3127H ¼” 131 32” ⅞” -
275 Brass 7545-40
3129H ½” 219 32” 1⅛” 3129-10*
3127P ¼” 131 32” 1⅛” -
3129P 300 219 32” 1⅛” 3129-10*
½”
SS8022P Stainless Steel 1⅜” ⅞” - ⅜” NPT Thrds
3127J ¼” 131 32” ⅞” -
Brass 7545-40
3129J ½” 219 32” 1⅛” 3129-10*
SS8001J ¼” 11
16 ”
350 ⅞” -
SS8002J Stainless ½” ⅞”
-
SS8021J Steel ¼” 11
16 ” ¼” NPSM Thrds
1⅜” SS8022G
SS8022J ½” ⅜” NPT Thrds
⅞”
3127K ¼” 1 32”
31
-
375 19 7545-40
3129K ½” 2 32” 1⅛” 3129-10*
3125L Brass 1 9 16” ⅝” Included
¼” 31 -
3127L 1 32” ⅞” 7545-40
3129L ½” 219 32” 1⅛” 3129-40P 3129-10*
SS8001L 400 ¼” 11
16 ”
⅞” -
SS8002L Stainless ½” ⅞”
-
SS8021L Steel ¼” 11
16 ” ¼” NPSM Thrds
1⅜”
SS8022L ½” ⅜” NPT Thrds
⅞”
3127U ¼” 131 32” -
Brass 7545-40
3129U ½” 2 19 32” 1⅛” 3129-10*
SS8001U ¼” 11
16 ”
450 ⅞” -
SS8002U Stainless ½” ⅞”
-
SS8021U Steel ¼” 11
16 ” ¼” NPSM Thrds (.156 Orifice)
1”
SS8022U ½” ⅞” ⅜” NPT Thrds
(.156 Orifice)
* 1⁄2” F. NPT outlet connection.

D16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
DuoPort® Pressure Relief Valve Manifolds for Small Storage Containers
8542 Series
Application
Designed especially for use as a primary relief device on smaller
stationary storage containers, with 2” NPT threaded couplings.
These manifolds allow servicing or replacement of either of the two
PRODU
relief valves without evacuating the container or loss of service. The

10
O

CT
operating lever selectively closes off the entrance port to the relief

RE

S
valve being removed while the remaining valve provides protection
for the container and its contents. The rating of each manifold is

10

Y
NT
based on actual flow through the manifold and a single pressure relief E

Y
AR A
valve, taking friction loss into account. It is not merely the rating of the WA R R
relief valve alone.

Features
• Allows for relief valve removal and replacement on a periodic basis
without shutting down and evacuating the container.

• Unique seat ring assemblies provide a smooth tubular section to


preclude turbulence and assure more efficient flow capacity.

• Operating lever is only locked in the mid-position or in a position


to seal either relief valve. Placement of the clapper disc in an
intermediate position could restrict flow through one of the relief
valves, causing it to chatter and destroy the resilient seat disc. UL
®

• A rubber plug with chain is provided to protect manifold outlet


threads where the relief valve has been removed.

• “Pop-action” design insures maximum protection with only minimal


product loss at moderately excessive pressures.

• Resilient relief valve seat disc provides “bubble-tight” seal. D


• Relief valves are ASME rated for use with LP-Gas and anhydrous
ammonia.

Manifold Materials
Body.................................................................................. Ductile Iron ?
Clapper Disc................................................................ Stainless Steel
Bleeder Valve.............................................................. Stainless Steel
Seat Disc.................................................................................... Teflon
Packing............................................................................ Polyethylene

Relief Valve Materials


Body....................................................................... Forged Aluminum*
Spring Guide....................................................................... Aluminum
Spring............................................................................. Coated Steel
Seat Disc................................................... Resilient Synthetic Rubber
*A special coating is applied to the inlet threads to minimize the possibility of electrolytic action.

Ordering Information
Flow Capacity SCFM/Air**
Relief Valve Included
Start to Application (at 120% of set pressure)
Container
Discharge
Part Number Connection UL Rating
Setting Inlet Accessory ASME Rating
M. NPT (at 120%
PSIG Quantity Part Number Connection (at 120% of
LP- Pipeaway of set
NH3 M. NPT set Pressure)
Gas Adaptors Pressure)
8542G Yes No 3135MG 3135-10* 5250 (1) NA
250
AA8542UA250 2” 2 AA3135MUA250 1¼” AA3135- 6430 (1) 6341 (1)
No Yes
AA8542UA265 265 AA3135MUA265 10* 6615 (1) 6703 (1)

* 2” F. NPT outlet connection.


** Flow rating based on number of relief valves indicated in parenthesis ( ). Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow rates as discussed in forewording information.

D17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
MultiportTM Pressure Relief Valve Manifold Assemblies
for Large Storage Containers A8560, A8570 and AA8570 Series
Application
Designed especially for use as a primary relief device on large
stationary pressurized storage containers with flanged openings.
These manifolds incorporate an additional relief valve, not included
A8560
in the flow rating, allowing for servicing or replacement of any one of
the relief valves without evacuating the container. The handwheel on
A8570
the manifold selectively closes off the entrance port to the relief valve
being removed while the remaining relief valves provide protection for
the container and its contents. All manifold flow ratings are based on
flow through the relief valves after one has been removed for service
or replacement.

Features
• Allows for relief valve removal and replacement on a periodic basis
without shutting down and evacuating the container.

• “Pop-action” design of relief valves insures maximum protection with


only minimal product loss at moderately excessive pressures. UL
®

• A rubber plug with chain is provided to protect manifold outlet


threads where the relief valve has been removed.

• May be mounted directly to a welding neck flange or manhole cover


plate. Requires no inlet piping.

• Relief valves designed to automatically reseat firmly after


discharge.

• Resilient relief valve seat disc provides “bubble-tight” seal.

D • Relief valves are ASME rated for use with LP-Gas and anhydrous
ammonia.

Materials
Body.................................................................................. Ductile Iron
Resilient Parts............................................................................ Teflon
Clapper Disc................................................................ Stainless Steel
Bleeder Valve.............................................................. Stainless Steel

Bolt Stud and Nut Assemblies


Part For Use Number
Number Consists of With: For Connection To: Required
Modified 3” - 300#
7560-55 1-Bolt Stud All RegO and 4”-ASA 300#
Welding Neck Flange 8
and Nut Multiports™
7560-56 Manhold Cover Plate

Relief Valve Materials


Description A8563, A8564, A8573, A8574
Body Upper Cold Rolled Steel Lower Ductile Iron PRODU

10
O
Liner Stainless Steel
G

CT
RE

Spring Guide Stainless Steel


S

Spring Coated Steel


10

Seat Disc Resilient Synthetic Rubber


NT

E
Y

*A special coating is applied to the inlet threads to minimize possibility of electrolytic action. AR A
WA R R

D18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Typical RegO Multiport™ Pressure Relief Valve Manifold

RegO® Pressure Relief Valve Safety Groove Excessive stress on


“Pop-action” insures maximum vent piping attached to relief valve
protection with only minimum UL®
will break valve body at this point,
fluid loss at moderately leaving valve fully operative.
excessive pressures.
Handwheel
Large, heavy duty handwheel has
raised port numbers for selective
Weep Hole Deflector positioning of clapper disc. Raised
Port design of deflector prevents “arrow” below handwheel indicates
any ignited fluid ejected from the exact position of clapper disc at all
weep hole, while the relief valve is times.
functioning, from impinging on the
storage container or adjacent piping Clapper Disc
and equipment. Shown in position to remove relief
valve. Normally, clapper disc is
positioned between any two relief
valves.
Resilient Seat Disc
Assures positive shut-off. Bleeder Valve
Shown in “closed” position to bleed
off pressure trapped between relief
Manifold Seat Ring valve and clapper disc prior to
Has integral teflon seat ring for removal of relief valve.
positive shutoff of valve port by
clapper disc. Ductile Iron Body
Rugged. Has corrosion resistant
lacquered finish.
Instruction Plate Flanged Tank Connection
For relief valve replacement. Available with either a modified ASA
3” (4” port opening) or a 4” ASA
Plug Assembly
Protects manifold outlet threads
300# flanged connection. Mates
respectively with modified ASA 3”.
D
and keeps foreign material out 300 lb. flat face steel flange and
of manifold when relief valve is ASA 4” 300 lb. 1⁄16” raised face
removed for retest. steel flange.

Spacious Manifold Port


Flange Dimensions Passages Large unobstructed throat
assures minimum capacity loss.
Manifold Port Flange
Series Flange Size Flange Drilling Diameter Gasket Manifold is bolted directly to storage
container opening, eliminating any
Modified 3” (8) ⅞” Bolt Holes on a
A8560 300# 6⅝” Bolt Circle Diameter 4”
3” restrictions.
PRODU
7564-48

10
O
(4” Port Dia) Flat Faced.
G

Gasket
CT
RE

(8) ⅞” Bolt Holes on a


A8570 4” ASA 4” Johns-Manville Spirotallic flange
10

7⅞” Bolt Circle Diameter 4”


NT

E
Y

AR A
AA8570 300#
1/16” Raised Faced.
7565-48 WA R R gasket furnished with each manifold
assembly.

Ordering Information
Application Relief Valve
Flow Capacity SCFM/Air**
Accessories At 120% of Set Pressure
Start To Container Inlet
Discharge Flange Connection Pipeaway
Part Number Setting PSIG LP-Gas NH3 Connection Quantity Part Number M. NPT Adapters UL Rating ASME Rating
A8563G 3 18,500 (2)
3”-300#*
A8564G 4 27,750 (3) Not
A3149MG
A8573G 3 18,500 (2) Applicable
4”-300#
A8574G 4 27,750 (3)
250 Yes Yes 2½” ****
A8563AG 3 18,300 (2)
3”-300#*
A8564AG 4 Not 27,400 (3)
A3149G
A8573AG 3 Applicable 18,300 (2)
4”-300#
A8574AG 4 27,400 (3)
* For use with modified 300# ANSI flange with 4” port. *** 2” F. NPT outlet connection.
** Flow rating based on number of relief valves indicated in parenthesis ( ). **** Outlet 31⁄2-8N (F) thread, will accept 3” M. NPT pipe thread.
Flow rates shown are for bare relief valves. Adapters and pipeaways will
reduce flow rates as discussed in forewording information.

D19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ECII® Warning Notice
The following warning information, Part Number 8545-500, is included
with each shipment of pressure relief valves and relief valve manifolds
to the first purchaser of the product from the factory.

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors.

Cross Reference by Part Number

3125L..........................D16 3129U....................... D16 SS8001J...........................D16 AA8542UA250...................D17


AA3126L030.....................D14 AA3130UA250................ D14 SS8001L...........................D16 AA8542UA265...................D17
AA3126L250.....................D14 AA3130UA265................ D14 SS8001U..........................D16 8543G..........................D11
AA3126L312.....................D14 3131G....................... D14 SS8002G..........................D16 8543T...........................D11
3127G.........................D15 T3132G....................... D14 SS8002J...........................D16 8544G..........................D11
3127G.........................D16 W3132G....................... D14 SS8002L...........................D16 8544K...........................D11
3127H.........................D16 MV3132G....................... D14 SS8002U..........................D16 8544T...........................D11
3127J..........................D16 3132G....................... D14 SS8021G...........................D16 8545AK........................D12
3127K..........................D15 3133G....................... D14 SS8021J............................D16 A8563AG........................D19
3127K..........................D16 3135G....................... D14 SS8021L............................D16 A8563G..........................D19
3127L..........................D16 AA3135UA250................ D14 SS8021U...........................D16 A8564AG........................D19
3127P..........................D16 AA3135UA265................ D14 SS8022G...........................D16 A8564G..........................D19
3127U.........................D16 A3149G....................... D14 SS8022J............................D16 A8573AG........................D19
3129G.........................D15 A3149L050.................. D14 SS8022L............................D16 A8573G..........................D19
3129G.........................D16 A3149L200.................. D14 SS8022P...........................D16 A8574AG........................D19
3129H.........................D16 7534B........................ D13 SS8022U...........................D16 A8574G..........................D19
3129J..........................D16 7534G....................... D13 A8434G..........................D10 8684G..........................D13
3129K..........................D15 7560-55..................... D18 A8434N..........................D10 8685G..........................D13
3129K..........................D16 7560-56..................... D18 A8436G..........................D10 970S.............................H10
3129L..........................D16 7583G....................... D13 A8436N..........................D10
3129P..........................D16 SS8001G....................... D16 8542G..........................D17

D20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section E
E E

Globe and Angle Valves

E1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY Except as expressly set forth above, and subject to the limitation of
liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
LIMITED 10 YEAR WARRANTY OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
Engineered Controls International, Inc. (“ECII”) warrants to the original PARTICULAR PURPOSE, with respect to its products and parts,
purchasers the products and repair kits manufactured by it to be free whether used alone or in combination with others. ECII disclaims all
from defects in materials and workmanship under normal use and warranties not stated herein.
service for a period of 10 years from the date of manufacture. If within
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of LIMITATION OF LIABILITY
receipt , will repair, replace F.O.B. point of manufacture, or refund the
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of NOTICE TO USERS OF PRODUCTS
any and all claims of buyer arising out of such defect.
The Limited Warranty stated above is a factory warranty to the first
This warranty does not extend to any product or part that is not purchasers of ECII products. Since most users have purchased
installed and used continuously after installation in accordance with these products from ECII distributors, the user must within thirty (30)
ECII’s printed instructions, all applicable state and local regulations, days after the user’s discovery of what user believes is a defect,
and all applicable national standards, such as those promulgated by notify in writing and return the product to the distributor from whom
NFPA, DOT and ANSI. This warranty does not extend to any product he purchased the product/part. The distributor may or may not at
or part that has been damaged by accident, misuse, abuse, failure to the distributor’s option choose to submit the product/parts to ECII,
maintain, or neglect, nor does it extend to any product or part which pursuant to this Limited Warranty. Failure by buyer to give such
has been modified, altered, disassembled, or repaired in the field. written notice within thirty (30) days shall be deemed an absolute and
This warranty does not cover any cosmetic issues, such as scratches, unconditional waiver of buyer’s claim for such defects. Acceptance
dents, marring, fading of colors or discoloration. of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

Because of a policy of continuous product improvement, ECII


E reserves the right to change designs, materials or specifications
without notice.

E2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
E
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Cross Reference by Part Number.............................................E20
Flange Seal Valves....................................................................E12
Hose-End Filling Valve Safety Warning.......................................E4
Multipurpose Valves..................................................................E16
Quick-Acting Horse End Valves...................................................E6
Quick-Acting Minimum Loss Valves............................................E5
Quick-Acting Valves.....................................................................E7
Tank Car Valve..........................................................................E15
Vapor Head Manifold.................................................................E14
“V”-Ring Seal Valves...................................................................E9
Warnings...................................................................................E20

E3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Hose-End Filling Valves (With ACME Connectors)
Safety Warnings Purpose
In its continuing quest for safety, Engineered Controls International, Inc. publishes a series of bulletins explaining
the hazards associated with the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these
factual bulletins will make clear to LP-Gas dealer managers and service personnel, that the utmost care and
attention must be used in the installation, inspection, and maintenance of these products, or problems could
occur which would result in injuries and property damage.

The National Fire Protection Association Pamphlet #58 - 2004 Edition, “Liquified Petroleum Gas Code” states
that, “persons who transfer liquid LP-Gas, who are employed to transport LP-Gas, or whose primary duties fall
within the scope of this code shall be trained in proper handling procedures. Refresher training shall be provided
at least every three years. The training shall be documented.” These “ECII® Safety Warnings” may be useful in
training new employees and reminding older employees of hazards that can occur. It is recommended that all
employees be furnished with a copy of NPGA Safety Pamphlet 306-88, “LP-Gas Regulator and Valve Inspection
and Maintenance.”

Nature of Warnings
It is recognized that warnings should be as brief as possible, but
factors involved in filler valve and filling valves failure are not simple.
They need to be fully understood so that proper procedures and
maintenance can be used to prevent accidents. If there is a simple
warning, it would be:

Loosen filling valve from filler valve very slowly.


If there is a leak, know procedure to follow.
Loosen slowly.
This bulletin is not intended to be an exhaustive treatment of the
If gas continues
subject of filler valves and certainly does not cover all safety practices
to vent, retighten
that should be followed in the installation, operation and maintenance
ACME connector
of LPGas systems, which include filler and filling valves.
and follow company
Hose-End Filling Valves With ACME Connectors emergency
procedures.
Hose-end valves must never be dragged over the ground or
dropped or banged into the truck when the hose is reeled in.
E Inspection of Quick Acting Filling Valves
● Valves should be inspected daily to make sure locking mechanism
They could open accidentally or they could be damaged. Dragging
functions properly.
will cause abnormal wear and eventual valve failure. Foreign material
will lodge in the connector which can cause failure of the filler valve.
● The ACME threads should be examined for wear, dents or nicks and
the seating area should be clean and smooth.
To prevent hazardous conditions, operators should follow this
procedure on every filling application: ● The retaining ring on the filler connection should be examined to
make sure it is properly holding the female ACME rotating nut or
● Always wear gloves and eye protection. handle so as to keep the surface that seats on the filler valve gasket
protected.
● Check for foreign material in hose-end valve and the filler valve,
and if present, remove with extreme care. If material cannot be ● If any problems are evident, valves should be immediately replaced
safely removed, do not proceed with filling and replace valve. or repaired.

● Make sure the ACME connector spins on easily by hand. Larger Filler and Filling Valves
● If leak is noticed when filling is started, stop the operation and For 2¼” and 3¼” valves with ACME connections, use only the special
correct the leaking condition. wrenches designed for the purpose.

● After filling, bleed the gas trapped between the filler valve Do not use pipe wrenches or hammers to tighten the connections. All
and hose-end valve by using the vent on the hose-end valve of the previous warnings about the smaller valves also apply here.
or by slightly loosening coupling nut to vent the gas before
disconnecting. General Warning
All ECII® products are mechanical devices that will eventually
If gas does not stop venting, then filler valve or hose-end become inoperative due to wear, contaminants, corrosion and aging
valve is leaking. Do not disconnect filling connector. This is a components made of materials such as rubber and metal. The
hazardous situation and your company procedure for handling environment and conditions of use will determine the safe service
this problem must be carefully followed. life of these products. Periodic inspection and maintenance are
essential. Because ECII® products have a long and proven record of
Make sure your company has such a procedure. Inspection of quality and service, LP-Gas dealers may forget the hazards that can
Filling Valves with Handwheel occur because a filler valve or a filling valve is used beyond its safe
● Valves should be inspected at least once a month to be sure the service life. Life of these valves is determined by the environment
valve handle is tight and not damaged, that the stem is not bent and in which they “live.” The LP-Gas dealer knows better than anyone
that there is no “play” in the threads in the bonnet. “Play” will normally what this environment is. Note: There is a developing trend in state
not be noticed if the valve is under pressure. legislation and in proposed national legislation to make the owner of
products responsible for replacing products before they reach the
● The ACME threads should be examined for wear, dents or nicks and end of their safe useful life. LP-Gas dealers should be aware of the
the seating area should be clean and smooth. legislation which could affect them.
E4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks
and Dispensing Stations A7793A and A7797A
Application
Designed to vastly reduce the amount of product vented when
disconnecting bobtail delivery trucks, dispensing systems and
anhydrous ammonia nurse tanks.
These valves provide instant, full-on flow at the flip of a handle. Shut-
off is instant and the handle locks for added protection. This “top of UL
®

the line” hose-end valve is a fully contained unit that does not require
additional filling adapters or connectors.

Features
• Minimizes product venting loss, when disconnecting, instantly by
housing the seat disc at the bottom of the built-in ACME filling
connector.

• Vents less than 2cc of liquid when disconnected.

• “V”-ring spring-loaded pressure seal design provides for dependable,


leak-free operation. No packing to retighten or replace.

• Operator friendly. Contoured handle rotates a full 360° and large,


easy to grip filling connector make the valve easy to handle.

• Self locking handle is operator opened and closed to prevent


against accidental opening of the valve.

E
Materials
Body.................................................................................. Ductile Iron
“V”-Ring...................................................................................... Teflon
Stem............................................................................ Stainless Steel
Seat Disc............................................................. Synthetic Elastomer
ACME Connector.......................................... Aluminum w/Steel Insert
Seal Housing............................................................... Stainless Steel
Lever........................................................................... Stainless Steel
Bonnet............................................................. Cadmium Plated Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Flow at 1 PSIG (Cv) Pressure Drop*
Part Number Inlet Connection (F. NPT) Outlet Connection (F. ACME) Locking Handle
(GPM/Propane)
A7793A ¾” 1 ¾” Yes 16.0
A7797A 1” 1 ¾” Yes 16.0

* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: A7797 @ 9 PSIG = 16.0 x 9 = 48.0 GPM/propane. For NH3 flow,
multiply propane flow by .90.

E5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing
Stations A7707L and A7708L
Application
Designed especially for safe operator handling of LP-Gas in bobtail
delivery truck, dispensing systems and anhydrous ammonia nurse
tank service.

These valves provide instant, full-on flow at the flip of the handle
and provide instant positive shut-off with a handle lock for added
protection.

Features
• “V”-ring spring-loaded pressure stem seal provides for leak-proof
operation. No packing to retighten or replace.

• Self locking handle is operator opened and closed to prevent A7707L


against accidental opening of the valve.

• Large, contoured handle provides firm, comfortable grip.


UL
®

• Full swivel handle rotates 360° so the valve can be operated from
any angle.

• Built-in vent valve on the downstream side of the valve permits


bleeding of trapped product to assure safe uncoupling.

• Can be used with a variety of RegO® filling adapter connectors.

• Swivel seat disc minimizes grinding on the body seat and assures
longer service life.

E
Materials
Body.................................................................................. Ductile Iron
“V”-Ring...................................................................................... Teflon A7708L
Stem............................................................................ Stainless Steel
Seat Disc............................................................. Synthetic Elastomer
Valve Lever.................................................................. Stainless Steel
Seal Housing............................................................... Stainless Steel
Bonnet............................................................. Cadmium Plated Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Accessories
Filling Connectors**
Extended Compact
Inlet & Outlet Locking Flow at 1 PSIG Pressure Drop
Part Number Body Design Connection (F. NPT) Handle (Cv) (GPM/Propane)** Steel Brass Steel
A7707L Globe 18.0
1” Yes A7575L4 3175A A3175A
A7708L Angle 22.0

* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop.
Example: A7708L @ 9 PSIG = 22.0 x 9 = 66.0 GPM/propane. For NH3 flow, multiply propane flow by .90.
* * See appropriate catalog section for additional information.

E6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Quick-Acting Valves for Crop Driers and Charging Manifold Hoses
7554 Series
Application
7554S Series valves provide instant shut-off and fast opening control
on LP-Gas crop driers. They are also ideal for charging manifold
hoses, stationary fuel transfer hoses and other applications requiring
quick, positive shut-off. They are not for use with delivery truck hoses
because the handle could snag on the ground and open the valve as
the hose is reeled back to the truck.

7554L Series valves feature a locking handle device to help prevent


accidental opening of the valve. It is ideal for all the same applications
as the 7554S Series and may be used on delivery trucks as it
incorporates the locking handle design.

Both valve series must be installed so that flow through the valve is
opposite to that of a conventional globe valve. This allows the inlet
flow to assist in closing the valve and prevents the valve from being 7554S
opened by high pump pressures.

Features
• Quick-acting design speeds transfer operations, permitting rapid, UL
one-handed opening and closing. ®

• Resilient seat disc provides positive shut-off.

• Flange seal stem design provides for leak-proof operation. No


packing to retighten or replace.

• 7554L Series incorporates locking handle to prevent accidental


opening of the valve.

• Vent valve installed on the downstream side of the valve permits E


bleeding of trapped product to assure safe uncoupling.

• Swivel seat disc minimizes grinding on the body seat and assures
longer service life.

Materials
Body.................................................................................. Ductile Iron
Bonnet........................................................................................ Brass
“V”-Ring...................................................................................... Teflon
Stem............................................................................ Stainless Steel 7554LV
Seat Disc............................................................. Synthetic Elastomer
ACME Connector.......................................... Aluminum w/Steel Insert
Seal Housing............................................................... Stainless Steel
Lever........................................................................... Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Inlet & Outlet Connection (F. NPT) Locking Handle Flow At 1 PSIG (Cv) Pressure Drop* (GPM/Propane)
7554SAV No
½” 7.3
7554LAV Yes
7554SV No
¾” 11.3
7554LV Yes
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table
by square root of pressure drop. Example: 7554LV @ 9 PSIG = 11.5 X 9 = 34.5 GPM/
propane.

E7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Quick-Acting Valves for Cylinder Charging Hoses
7053T, A7553A, and 7901T Series

Application
Designed primarily for use on cylinder charging hoses to provide fast,
convenient shut-off and fast opening.

These valves must be installed so that flow through the valve is in


the opposite direction to that of a conventional globe valve. This
allows the inlet flow to assist in closing the valve, and even more
important, helps prevent the valve from being forced open by high
pump pressure.

Features
A7553A
• Quick-acting design speeds transfer operations.
UL
• Permits easy, one-handed opening and closing of the valve. ®

• O-ring stem seal design.

• Provides quick, positive shut-off.

Materials
Body (7053T, 7901)........................................................ Forged Brass
Body (A7553).................................................................... Ductile Iron
E O-Ring....................................................... Resilient Synthetic Rubber 7901TA
Bonnet Assembly (7053T, 7901)................................................ Brass
Bonnet Assembly (A7553)............................................................ Steel
Seat Disc.................................................... Resilient Synthetic Rubber
Handle (7053T, 7901).................................................................. Brass
Handle (A7553)............................................................................ Steel
Springs.......................................................................... Stainless Steel

PRODU

10
O
G

CT
RE

7053T
S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Inlet Connection (F. NPT) Outlet Connection (F. NPT) Body Material Flow At 1 PSIG (CV) Pressure Drop* (GPM/Propane)
7901T Brass
¼” ¼”
A7553A Ductile Iron
7901TA ⅜” ⅜”
1.95
7901TB ¼”
Brass
7901TC ½”
½”
7053T
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square
root of pressure drop. Example: 7901T @ 9 PSIG = 1.95 x 9 = 5.85 GPM/propane. For NH3 flow,
multiply propane flow by .90.

E8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
“V”-Ring Seal Globe and Angle Valves
General Information Installation and Operation Note
RegO® Globe and Angle Valves are designed and manufactured Containers and pipe lines should be thoroughly cleaned before globe
especially to meet the rigid requirements of the LP-Gas industry. The and angle valves are installed. Large particles of solid foreign matter
high quality construction and wide variety of sizes and styles also can permanently damage the seating surface in the valve body,
make them highly suited to many other industries such as anhydrous causing the valve to leak. Use a minimum amount of a suitable pipe
ammonia, chemical and petrochemical. dope on the male connecting threads as excess amounts may fall off
and be carried into the valve, causing damage to the seat or other
These ductile iron valves are available in both threaded and flanged operating parts.
connections. Threaded connections are available in 1⁄2” F. NPT to 3”
F. NPT sizes. Flanged connections are available in 11⁄2”, 2” and 3”
It is totally unnecessary to use excess force in opening or closing
pipe sizes.
RegO® valves. The type of seat disc material used and the general
The ductile iron used in these valves has a 60,000 PSIG tensile design of these valves permits them to be opened and closed easily.
strength which closely approaches that of steel castings. Its yield Proper valve operation insures unusually long life.
strength of 45,000 PSIG and elongation of 15% is also comparable
to that of steel castings. These material features assure the ability of Wrenches must never be used to operate valves equipped with
the valve body to withstand impact, wrenching stresses and thermal handwheels and designed for hand operation.
shock. This ductile iron conforms to ASTM specification A395.
Downstream Accessory Boss
RegO® globe and angle valves are designed for working pressures
These RegO® valves incorporate a plugged 1⁄4” F. NPT boss on
up to 400 PSIG WOG and for operating temperatures from -40° F. to
the downstream side of the body for attaching either a hydrostatic
+160° F.
relief valve or vent valve. Boss size on the 2” and 3” valves has been
increased to allow a ¾” drilling for accommodation of a standard by-
“V”-Ring pass valve or jumper lines.
Stem Seal Hydrostatic Relief—When the design of the piping installation
is such that liquid may be locked between two shut-off valves,
a hydrostatic relief valve should be installed in the lines
between the valves. The pressures which can develop due to
The “V”-ring spring-loaded pressure seal used in these RegO® globe temperature increase in a liquidfull line are tremendous and
and angle valves is the most effective stem seal yet developed. It can easily damage the valves or piping unless a hydrostatic
should not be confused with conventional valve stem packing where
relief valve is installed.
the seal is obtained by compressing the packing around the stem by
means of a packing gland with resultant hard operation and frequent
packing replacement.
Vent Valve—If the globe or angle valve is used as a shut-off
valve on a loading hose, a vent valve should be installed in the
E
The wax like surface of the teflon “V”-ring seal and consequent low
friction assures leak-tight performance for an indefinite period where downstream boss to allow liquid trapped beyond the shut-off
periodic retightening of the packing is not required and the seal valve to be vented before disconnecting the hose coupling.
provides extra long service life.

In the RegO® “V”-ring design, the seal is effected by the pressure


Replace Gate Valves with Flanged Valves
expanding the “V”-shape of the seal, forcing it against the stem and Except for standard flange sizes, RegO® Flanged Globe and Angle
bonnet surfaces to prevent leakage. The higher the pressure within Valves are smaller and lighter than contemporary valves, thus
the valve, the more effective the seal becomes. A spring loaded reducing price and shipping costs and making them far easier to
washer under the “V”-rings keeps them in an expanded position to install. RegO® face to face flange dimensions conform to gate valve
assure an effective seal under low pressure conditions. A wiper ring, dimensions, making replacement of most gate or plug valves with
located above the seal, keeps the seal free from grit, and/or other
RegO® valves simple and easy.
foreign material that may hamper operation.

General Features
Heavy Duty Handwheel
Teflon “V”-Ring
provides easy operation.
Spring-Loaded Pressure
Seal for leak-proof
O-Ring Wiper keeps sand operation. No packing to
and grit away from pressure adjust or replace.
seal and stem threads.

Heavy Duty Acme Threads Stainless Steel Stem is centerless


for quick action and smooth ground to provide a smooth
operation. sealing surface.

Rugged Ductile Iron Body


Swivel Seat Holder
won’t crack or fracture
promotes long life.
from wrenching, dropping
or hammer blows.
Synthetic Rubber Seat
assures easy, positive Circular Bridge is
shut-off. contoured to provide
extra high capacity and
low pressure drop.

E9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
“V”-Ring Seal Globe and Angle Valves for Bulk Storage Containers,
Transports, Bobtails and Plant Piping A7500 Series and TA7500 Series
Application
Specifically designed to assure positive shut-off and long,
maintenancefree service life in liquid or vapor service on bulk storage
containers, transports, bobtails, cylinder filling plants and plant
piping.

The high quality construction and wide variety of sizes make them
highly suited for use with LP-Gas, anhydrous ammonia and in the
chemical and petrochemical industries.
TA7034

Features UL
®

“V”-ring spring-loaded pressure stem seal provides for leak-proof


operation. No packing to retighten or replace.
A7518FP
• Circular bridge in the globe design and a dropped seat in the angle
design achieve greater flow with less pressure drop.

• Swivel seat disc assembly minimizes the seat disc from grinding on
the body seat. The seat disc stops rotating as soon as it touches
the body seat. This feature provides for good seat alignment and
A7505AP
assures long seat life.

• 1⁄4” F. NPT plugged boss on the downstream side of the valve body A7514AP
allows attachment of a hydrostatic relief valve or vent valve.

• “V”-ring stem seal virtually eliminates hard to turn handles frequently


encountered with packed type seals.

• Heavy duty rolled ACME stem threads provide quick action and long
service life. A7513AP

E
Materials
Body.................................................................................. Ductile Iron
Bonnet (7034, 7505-7508).......................................................... Steel
Bonnet (7509-7518).......................................................... Ductile Iron
Valve Stem.................................................................. Stainless Steel
Wiper Ring................................................................ Synthetic Rubber A7517AP
Seat Disc.............................................................. See Ordering Chart PRODU A7517FP

10
O
“V”-Rings.................................................................................... Teflon
G

CT
RE

Handwheel........................................................................ Ductile Iron


10

Spring.......................................................................... Stainless Steel


NT

E
Y

AR A
WA R R

Ordering Information
Part Number Flow at 1 PSIG Pressure Accessories
Drop (Cv) (GPM/
Buna N Seat Discs Teflon Seat Discs* Propane)***
Inlet and Outlet Port Hydrostatic
Globe Angle Globe Angle Connection Diameter Globe Angle Relief Valve Vent Valve
- - TA7034P TA7034LP ½” F. NPT 10.0 14.8
¾”
A7505AP A7506AP TA7505AP TA7506AP ¾” F. NPT 12.0 17.7
A7507AP A7508AP TA7507AP - 1” F. NPT 1” 17.8 22.0
A7509BP A7510BP TA7509BP TA7510BP 1¼” F. NPT 1¼” 36.5 54.0
A7511AP A7512AP TA7511AP TA7512AP 1½” F. NPT 43.0 55.5
1½” SS8001U TSS3169
A7511FP - TA7511FP 1½” Flange** 46.0 -
-
A7513AP A7514AP TA7513AP 2” F. NPT 75.0 88.5
2”
A7513FP A7514FP TA7513FP TA7614FP 2” Flange** 78.0 133.0
A7517AP A7518AP TA7517AP - 3” F. NPT
3⅛” 197.0 303.0
A7517AP A7518FP TA7517FP - 3” Flange**

* Teflon seat discs on valves built to order.


* * 300# ANSI R.F. Flange.
* * * To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in chart by square root of pressure drop.
Example: 7514FP @ 9 PSIG = 133 x 9 = 399 GPM/propane. For NH3 flow, multiple propane flow by .90.

E10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Globe and Angle Valve Dimensions

Dimensions
Flanges
Valve Number
Drawing (A or TA Prefix) Inlet & Outlet Port Diameter A B C D E F G

7034P ½” F. NPT
¾” 311⁄16”
7505AP ¾” F. NPT -

7507AP 1” F. NPT 1” 45⁄16”


4¾” - - - -
A 7034LP ½” F. NPT
¾” 1¾”
7506AP ¾” F. NPT -
C B
B 7508AP 1” F. NPT 1” 2”

G 7509BP 1¼” F. NPT 1¼” 6¾” 4⅞”

A
7511AP 1½” F. NPT 1½” 6 ⁄ ”
13 16 53⁄16” -
- - - -
7513AP 2” F. NPT 2” 73⁄16” 5⅞”

C 7517AP 3” F. NPT 3⅛” 13¼” 9” 9”

G 7510BP 1¼” F. NPT 1¼” 6¾” 2¼”

7512AP 1½” F. NPT 1½” 613⁄16” 27⁄16”


A 5¼”
7514AP 2” F. NPT 2” 73⁄16” 211⁄16” - - - -

B 7518AP 3” F. NPT 3⅛” 11¾” 4”


B 9”
G
7511FP 1½” Flange 1½” 79⁄16” 7½” 6⅛” ¾” 2⅞”
5¼”
E
E
A
7513FP 2” Flange 2” 87⁄16” - 8½” 6½” ⁄ ”
13 16 3⅝”
F D

7517FP 3” Flange 3⅛” 13¼” 11⅛” 8¼” 1⅛” 5” 9”


C

7514FP 2” Flange 2” 7½” 5¼” 6½” ⁄ ”


13 16 3⅝” 5¼”

A
-
D

B
7518FP 3” Flange 3⅛” 11¾” 6¼” 8¼” 1⅛” 5” 9”
E
D B
F

NOTE: Regarding 7505AP through 7510BP — the thread used for assembling the bonnet to the body of the valve is a left hand thread. We advise our customers to be cognizant of this assembly
design in attempting to remove the bonnets of these valves in order to avoid serious damage to the valves.

Flange Dimensions
Valve Number (A or TA
Prefix) Size Flange Drilling D E F H

⅞” Bolt Holes on a 4½”


7511FP 1½” 6⅛” ⁄ ”
13 16 2⅞” ¾”
Bolt Circle Diameter

7513FP ¾” Bolt Holes on a 5”


2” 6½” ⅞” 3⅝” ⁄ ”
13 16

7514FP Bolt Circle Diameter

7517FP ⅞” Bolt Holes on a 6⅝”


3”* 8¼” 1⅛” 5” 11⁄16”
7518FP Bolt Circle Diameter

* Reducing screwed flanges are available for reducing 11⁄2” flange to 1 or 11⁄4” pipe thread and 3” flange to 21⁄2” pipe thread. Order from your local piping supplier.

E11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Flange Seal Globe and Angle Valves

General Information Leak-tight performance is assured and periodic adjustment is not


Globe and Angle Valves, incorporating the synthetic rubber flange required. The synthetic rubber construction provides smooth operating
seal design, operate on the same principle as the “V”-ring valves. Gas performance with long service life.
pressure in the valve is exerted against the synthetic rubber flange, These valves all incorporate a plugged 1⁄4” NPT side boss on the
forcing it tightly against the stem. downstream side of the valve that can be equipped with a hydrostatic
relief valve or vent valve.

Please be familiar with the “Installation and Operation Note” and


“Downstream Accessory Boss” section of the “V”-ring valve design
general information before ordering these valves.

Nylon bearing
General Features surrounds stem to
Rugged quick-acting prevent galling.
Acme threads on stem.
Threads are under flange Rubber flange ring
ring . . . dust, sand and grit stem seal effectively
can’t reach them. prevents gas escape.
The higher the
Swivel seat cannot pressure, the tighter
grind during valve the seal.
opening or closing.
Metal to metal back
Synthetic Rubber seat permits
E Seat Disc replacement of
flange ring with
valve in service.

Valve body made of shell molded ductile iron. Highly resistant


to cracking or fracturing from wrenching, dropping or hammer
blows. Bonnet and seal cap are steel on “A” prefix valves.

E12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling
Hoses and Plant Piping 7704, 7705 and 7706 Series

Application
Designed to assure positive shut-off and long maintenance-free
service life in liquid or vapor service. Ideally suited for use on cylinder
charging manifolds, truck filling hoses, bulk storage containers and
plant piping.

The high quality construction and wide variety of sizes make them
highly suited for use with LP-Gas, anhydrous ammonia and in the
chemical and petrochemical industries.

UL
®

Features A7704P 7704 P


• Available with either a brass bonnet and bronze stem for LP-Gas A7704 P
service or a steel bonnet and stainless steel stem for combined 7705 P
A7705 P
LP-Gas and anhydrous ammonia service.

• Flange seal stem provides for leak-proof operation. No packing to


retighten or replace.

• Metal-to-metal back seat permits replacement of the flange ring with


the valve in service.

• Plugged 1⁄4” NPT boss on downstream side of valve accommodates


hydrostatic relief valve or vent valve.

• Swivel seat disc minimizes grinding on the body seat and assures
longer service life. E
• “Dropped seat” body design of the angle valve provides high flow
capacity.

Materials
Body.................................................................................. Ductile Iron A7706 P 7704 LP
Bonnet (7704, 05, 06)................................................................. Brass A7704 LP
Bonnet (7704, 05, 06).................................................................. Steel 7706 P
Stem (7704, 05, 06).................................................................. Bronze A7706 P
Stem (7704, 05, 06)..................................................... Stainless Steel
Flange Ring.............................................................. Synthetic Rubber
Seat Disc.................................................................. Synthetic Rubber
PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Flow at 1 PSIG Pressure Drop (Cv) (GPM/Propane)* Accessories

Globe Angle Inlet & Outlet Connection (F. NPT) Globe Angle Hydrostatic Relief Valve Vent Valve
7704P 7704LP
½” 7.3 12.3
A7704P A7704LP
SS8001J or SS8001L TSS3169
7705P 7706P
¾” 11.5 17.7
A7705P A7706P

* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: A7704LP @ 9 PSIG =12.3 x 9 = 36.9 GPM/propane. For NH3 flow,
multiply propane flow by .90.

E13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Flange Seal Liquid Transfer Angle Valves for Bulk Storage Containers
7550 and 7551 Series
Application
Designed especially for liquid transfer of LP-Gas from consumer bulk
storage containers when used with a Chek-Lok® or equipped with
an integral excess flow valve. May also be used for vapor LP-Gas
service.

In NH3 applicator tanks they may be used as a vapor bleeder valve


or as a liquid withdrawal valve when installed in a coupling with a dip
pipe.

These liquid transfer valves are equipped with an integral excess


flow valve for liquid transfer directly from the tank fitting, or without an
integral excess flow for LP-Gas transfer through a Check-Lok®.

When equipped with an integral excess flow valve (7550PX), the


valve should be mounted in a forged steel 3000 lb. half coupling.
When mounted in a 11⁄4” x 3⁄4” NPT reducing coupling, the 3⁄4”
female thread in this coupling must be full length — equivalent to a
forged steel 3000 lb. half coupling.
7550P UL A7550PX
The excess flow valve will not function properly if these specifications ®

are not met. Refer to the Warning Bulletin in the Excess Flow Valve
Section of this catalog.

Features
• Flange seal stem design provides for leak-proof operation. No
packing to retighten or replace.

E • Large, unrestricted interior ports reduce pressure drop through the


valve, increasing capacity and preventing cavitation.

• Resilient swivel seat disc assures longer seat life and easy, positive
shut-off.

• Plugged 1⁄4” NPT outlet boss accommodates hydrostatic relief valve


or vent valve.

• Specifically designed for liquid transfer of LP-Gas with the Chek-


Lok®.

Materials
Body (7750, 51).......................................................................... Brass
Body (A7750, 51).................................. Cadmium Plated Ductile Iron
Bonnet (7750, 51)....................................................................... Brass
Body (A7750, 51)........................................................................ Steel
PRODU
Stem (7750, 51)........................................................................ Bronze

10
O
G

CT

Stem (A7750, 51)........................................................ Stainless Steel


RE

Flange Ring.............................................................. Synthetic Rubber


10

Seat Disc.................................................................. Synthetic Rubber


NT

E
Y

AR A
WA R R

Ordering Information
Flow at 1 PSIG Excess Flow Accessories
(Cv) Pressure Approximate
Inlet Connection Outlet Connection Integral Excess Drop* Closing Flow** Hydrostatic Relief
Part Number (F. NPT) (F. NPT) Flow (GPM/Propane) (GPM/Propane) Valve Vent Valve
7550P 3127U 3165
No 13.3 -
A7550P SS8001J TSS3169
¾”
7550PX 3127U 3165
¾” Yes - 16.0
A7550PX SS8001J TSS3169
7551P 3127U 3165
½” No 8.9 -
A7551P SS8001J TSS3169
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: 7550P @ 9 PSIG = 13.3 x 9 = 39.9 GPM/propane. For NH3 flow, multiple propane flow by .90.
* * For NH3 flow, multiply propane flow by .90.

E14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Tank Car Angle Valves for Railroad Tank Cars
TA7894P

Application AAR Approval #E-049015


Designed especially for transfer of LP-Gas and anhydrous ammonia
in railroad tank car service.

The combined heavyweight ductile iron castings and precision


machining provide ruggedness and superior performance in working
pressures up to 400 PSIG.

Features
• “V”-ring spring-loaded pressure seal design provides dependable,
leak-free operation. No packing to retighten or replace.

• Wiper o-ring eliminates entrance of dirt and grit into stem area that
can prohibit smooth operation.

• Heavy duty ACME stem threads give quick action and are
hardened for long service life.

• Swivel seat reduces scoring of seat disc and provides positive


shut-off.

• Full diameter seat provides greater flow capacity and low pressure
drop.

• Plugged ¼" NPT boss on downstream side of valve accommodates


vent valve or hydrostatic relief valve.

• Equipped with a malleable iron plug and chain installed in the


valve outlet.
UL
E
®

51⁄4"

Materials
Body.................................................................................... Ductile Iron
“V”-Rings......................................................................................Teflon
O-Ring........................................................................Synthetic Rubber 103⁄8"
Stem.............................................................................. Stainless Steel Approx.
Bonnet................................................................................. Ductile Iron
Seat Disc......................................................................................Teflon
Handwheel.............................................. Cadmium Plated Ductile Iron
311⁄16"
Approx.

PRODU

10
O
8"
G

CT
RE

Approx.
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Accessories
Outlet Connection Flow At 1 PSIG (Cv) Hydrostatic Relief
Part Number Inlet Connection ([Link]) Pressure Drop Valve Vent Valve
TA7894P Tank Car Flange 2” 112 SS8001U TSS3169
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: TA7894P @ 9 PSIG = 112 x 9 = 336 GPM/propane. For NH3 flow,
multiply propane flow by .90.

E15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Multipurpose Valve for Filling of NH3 Containers
A8016DBC
Application
Designed specifically for use as a manual filler valve on anhydrous
ammonia applicator tanks. This valve incorporates an integral back
check valve.

Features
• Positive seating back check valve opens for maximum flow at
minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.

• Back Check seat is fully contained in the tank coupling for maximum
protection in the event of external damage to the valve.

• Resilient seat disc assembly is fully contained on three sides for


bubble-tight shut-off and long service life.

• “V”-ring spring-loaded stem seal design requires no repacking or


field adjustment.

• Specially machined break-away groove beneath ACME threads


will shear-off with excessive pull on the hose and leave the valve A8016DBC
body intact.

• Plugged 1⁄4” NPT boss accommodates vent valve or hydrostatic UL


®
relief valve.

E
Materials
Body.................................................................................. Ductile Iron
Bonnet......................................................................................... Steel
“V”-Rings.................................................................................... Teflon
Stem............................................................................ Stainless Steel
Seat Disc.................................................. Resillient Synthetic Rubber
Back Check Valve........... Stainless Steel, Steel and Synthetic Rubber
Springs........................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Filling Capacity at 20 PSIG Accessories
Part Number Inlet Connection Filling Connection
Pressure Drop GPM/NH3 Hydrostatic Relief Valve Vent Valve
A8016DBC 1 1/4” 1 3/4” 95 SS8001J TSS3169
* Determined at 9.5 to 12 PSIG differential.
* * Determined at 100 PSIG inlet.

E16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Multipurpose Valve for Filling of NH3 Containers
A8016DP
Application
Designed specifically for use as a manual valve or vapor equalizing
valve on anhydrous ammonia applicator and nurse tanks.

This valve incorporates an integral excess flow valve. When product


is required, the valve must completely open and backseated to allow
the excess flow valve to function properly as explained in the excess
flow section of this catalog.

Features UL
®

• Positive-acting excess flow valve opens for maximum flow at


minimum pressure drop when filling -- regardless of the type of
coupling in which the valve is installed.

• Excess flow seat is fully contained in the tank coupling for maximum
protection in the event of external damage to the valve.

• Resilient seat disc assembly is fully contained on three sides for A8016DP
bubble-tight shut-off and long service life.

• “V”-ring spring-loaded stem seal design requires no repacking or


field adjustment.

• Specially machined break-away groove beneath ACME threads


will shear-off with excessive pull on the hose and leave the valve
body intact.

• Plugged 1⁄4” NPT boss accommodates vent valve or hydrostatic


relief valve.
E

Materials
Body.................................................................................. Ductile Iron
Bonnet......................................................................................... Steel
“V”-Rings.................................................................................... Teflon
Stem............................................................................ Stainless Steel
Seat Disc................................................... Resilient Synthetic Rubber
Excess Flow Valve.................................... Stainless Steel--Steel Body
Springs........................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Approximate Excess Flow
Closing Flows Accessories
Inlet Connection Filling Connection Filling Capacity At 20 PSIG Liquid* Vapor** Hydrostatic
Part Number (M. NPT) (M. ACME) Pressure Drop GPM/NH3 GPM/NH3 CFH/NH3 Relief Valve Vent Valve
A8016DP 1¼” 1¾” 95 44 24,000 SS8001J TSS3169
* Determined at 9.5 to 12 PSIG differential.
* * Determined at 100 PSIG inlet.

E17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 Containers
A8017D & A8020D
Application
Designed especially for use as a high capacity liquid withdrawal valve
on LP-Gas and anhydrous ammonia containers.

These valves incorporate an integral excess flow valve. When product


is required, the valve must be completely open and backseated to
allow the excess flow valve to function properly as explained in the
excess flow valve section of this catalog.

The A8017DH is equipped with a soft seated automatic differential


back pressure check valve in the seat disc assembly. This allows any
pressure build up in the liquid transfer line in excess of 10-15 psig
above the container pressure to flow back into the container. The
transfer hose is protected against excessive liquid or vapor pressure
entrapment, which adds materially to the useful life of flexible hose.
In addition to increasing hose service life, the equalizing valve adds
substantially to the operating safety of liquid transfer systems.

Features A8017DP

• Positive-acting excess flow valve opens for maximum flow at


minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.
UL
®

• Excess flow seat is fully contained in the tank coupling for maximum
protection in the event of external damage to the valve.

• Resilient seat disc assembly is fully contained on three sides for


bubble-tight shut-off and long service life.

• “V”-ring spring loaded stem seal design requires no repacking or


E field adjustment.

• A8017DH has two plugged 1⁄4” NPT ports, one on the top and the
other on the side, accommodate either a vent valve or hydrostatic
relief valve.

• A8020D has a alugged 1⁄4” NPT port that accommodates vent


valve, hydrostatic relief valve, or pressure gauge.

• A8017DH incorporates an automatic back check valve built into


the shut-off valve, eliminating the need for a separate hydrostatic
relief valve.

Materials
Body.................................................................................. Ductile Iron
Bonnet......................................................................................... Steel
Stem............................................................................ Stainless Steel
A8020D
Seat Disc.................................................. Resillient Synthetic Rubber PRODU

10
O
“V”-Rings.................................................................................... Teflon
G

CT
RE

Excess Flow Valve................................... Stainless Steel - Steel Body


10

Springs........................................................................ Stainless Steel


NT

E
Y

AR A
WA R R

Ordering Information
Accessories
Part Inlet Connection Outlet Connection Approximate Excess Flow Liquid Closing Flow** Hydrostatic Relief
Number (M. NPT) (F. NPT) (GPM/Propane) Valve Vent Valve
A8017DH 49 Not Required
1”
A8017DP 1¼” 55 TSS3169
SS8001J
A8017DLP ¾” 49
A8020D 1¼” 1” 78 SS8001J TSS3169

* Built-in back pressure check valve incorporated into shut-off valve.


* * Determined at 11.5 to 13.5 PSIG differential for 3⁄4” outlet and 9 to 12 PSIG differential for 1” outlet. For NH3 flow, multiply by .90.

E18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Multipurpose Valve for Filling and Liquid Transfer of NH3 Containers
A8018DP
Application
Designed primarily for use as a combination filler and liquid withdrawal
valve on three-opening applicator tanks or on nurse tanks.

This valve incorporates an integral excess flow valve. When product


is required, the valve must be completely open and backseated to
allow the excess flow valve to function properly as explained in the
excess flow valve section of this catalog.

Features
• Functions as both a filler valve and liquid transfer valve, in one unit.

• Positive acting excess flow valve opens for maximum flow at


minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.
UL
®
• Excess flow seat is fully contained in the tank coupling for maximum
protection in the event of external damage to the valve.

• Specially machined break-away groove beneath ACME thread of


filler valve will shear-off with excessive pull on the hose and leave
the valve body intact.

• Triple guide filler valve check provides for dependable shut-off A8018DP
performance when filling ceases.

• Resilient seat disc assembly is fully contained on three sides for


bubble-tight shut-off and long service life.

• “V”-ring spring loaded stem seal design requires no repacking or


field adjustment. E
• Plugged 1⁄4” NPT boss accommodates vent valve or hydrostatic
relief valve.

Materials
Body.................................................................................. Ductile Iron
Bonnet......................................................................................... Steel
Stem............................................................................ Stainless Steel
Seat Discs................................................. Synthetic Resilient Rubber
“V”-Rings.................................................................................... Teflon
Excess Flow Valve................................... Stainless Steel - Steel Body
Springs........................................................................ Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Filling Capacity At Approximate Accessories
Inlet Outlet Filling 20 PSIG Excess Flow
Part Connection Connection Connection Pressure Drop Liquid Closing Hydrostatic
Number (M. NPT) (F. NPT) ([Link]) GPM/NH3 Flow GPM/NH3 Relief Valve Vent Valve
A8018DP 1¼” 1” 1¾” 74 50 SS8001J TSS3169
* Determined at 9 to 12 PSIG differential.

E19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Warning Notice
The following warning information, Part Number 903-500, is included
with each shipment of Quick-Acting and Tank Car Valves to the first
purchaser of the product from the factory.

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors.

Cross Reference by Part Number


TA7034LP.............................E10 TA7511AP............................ E10 TA7517AP.............................. E10 A7704LP.......................... E13
7034LP............................. E11 7511AP............................ E11 7517AP.............................. E11 7704LP.......................... E13
TA7034P...............................E10 A7511FP............................ E10 TA7517FP............................... E10 A7704P............................ E13
7034P............................... E11 TA7511FP............................ E10 7517FP.............................. E11 7704P............................ E13
7053T.................................E8 7511FP............................ E11 7517FP.............................. E11 A7705P............................ E13
A7505AP............................E10 7511FP............................ E11 A7518AP.............................. E10 7705P............................ E13
TA7505AP............................E10 A7512AP........................... E10 TA7518AP............................... E10 A7706P............................ E13
7505AP............................ E11 TA7512AP........................... E10 7518AP.............................. E11 7706P............................ E13
A7506AP............................E10 7512AP........................... E11 A7518FP.............................. E10 A7707L.............................. E6
TA7506AP............................E10 A7513AP........................... E10 7518FP.............................. E11 A7708L.............................. E6
7506AP............................ E11 TA7513AP........................... E10 7518FP.............................. E11 A7793A . ........................... E5
A7507AP............................E10 7513AP........................... E11 A7550P................................. E14 A7797A.............................. E5
TA7507AP............................E10 A7513FP........................... E10 7550P................................. E14 TA7894P............................. E15
7507AP............................ E11 TA7513FP............................ E10 A7550PX.............................. E14 7901T.............................. E8
A7508AP............................E10 7513FP........................... E11 7550PX.............................. E14 7901TA............................ E8
7508AP............................ E11 7513FP........................... E11 A7551P................................. E14 7901TB........................... E8
A7509BP............................E10 A7514AP........................... E10 7551P................................. E14 7901TC........................... E8
TA7509BP............................E10 7514AP........................... E11 A7553A................................... E8 A8016DBC..................... E16
7509BP............................ E11 A7514FP........................... E10 7554LAV.............................. E7 A8016DP......................... E17
A7510BP............................E10 7514FP........................... E11 7554LV................................. E7 A8017DH......................... E18
TA7510BP............................E10 7514FP........................... E11 7554SAV.............................. E7 A8017DLP....................... E18
7510BP............................ E11 A7517AP........................... E10 7554SV................................ E7 A8017DP......................... E18
A7511AP.............................E10 A7517AP........................... E10 TA7614FP............................... E10 A8018DP......................... E19
A8020D........................... E18

E20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section F
F F

Excess Flow, Check, Filler


and Vapor Equalizing Valves

F1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY


Except as expressly set forth above, and subject to the limitation of
LIMITED 10 YEAR WARRANTY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
Engineered Controls International, Inc. (“ECII”) warrants to the original WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
purchasers the products and repair kits manufactured by it to be free PARTICULAR PURPOSE, with respect to its products and parts,
from defects in materials and workmanship under normal use and whether used alone or in combination with others. ECII disclaims all
service for a period of 10 years from the date of manufacture. If within warranties not stated herein.
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the LIMITATION OF LIABILITY
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. NOTICE TO USERS OF PRODUCTS

This warranty does not extend to any product or part that is not The Limited Warranty stated above is a factory warranty to the first
installed and used continuously after installation in accordance with purchasers of ECII products. Since most users have purchased
ECII’s printed instructions, all applicable state and local regulations, these products from ECII distributors, the user must within thirty (30)
and all applicable national standards, such as those promulgated by days after the user’s discovery of what user believes is a defect,
NFPA, DOT and ANSI. This warranty does not extend to any product notify in writing and return the product to the distributor from whom
or part that has been damaged by accident, misuse, abuse, failure to he purchased the product/part. The distributor may or may not at
maintain, or neglect, nor does it extend to any product or part which the distributor’s option choose to submit the product/parts to ECII,
has been modified, altered, disassembled, or repaired in the field. pursuant to this Limited Warranty. Failure by buyer to give such
This warranty does not cover any cosmetic issues, such as scratches, written notice within thirty (30) days shall be deemed an absolute and
dents, marring, fading of colors or discoloration. unconditional waiver of buyer’s claim for such defects. Acceptance
of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

F Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
without notice.

F2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
F
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Back Pressure Check Valves ..................................................... F25
Chek-Lok® Excess Flow Valves . ............................................... F18
Chek-Lok® Operation . ............................................................... F17
Cross Reference by Part Number .............................................. F28
Double Check Filler Valves ........................................................ F20
Excess Flow Valves . .................................................................... F8
Limitations of Excess Flows ......................................................... F7
Safety Warning for Excess Flows . ............................................... F4
Testing of Excess Flows ............................................................... F7
Troubleshooting of Excess Flows . ............................................... F6
Vapor Equalizing Valves ............................................................. F23
Warnings and Labels . ................................................................ F27

F3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Excess Flow Valves
Safety Warnings Purpose
In its continuing quest for safety, Engineered Controls International, Inc. publishes a series of bulletins explaining
the hazards associated with the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these
factual bulletins will make clear to LP-Gas dealer managers and service personnel, that the utmost care and
attention must be used in the installation, inspection, and maintenance of these products, or problems could
occur which would result in injuries and property damage.

The National Fire Protection Association Pamphlet #58 - 2004 Edition, “Liquified Petroleum Gas Code” states
that, “persons who transfer liquid LP-Gas, who are employed to transport LP-Gas, or whose primary duties fall
within the scope of this code shall be trained in proper handling procedures. Refresher training shall be provided
at least every three years. The training shall be documented.” These “ECII® Safety Warnings” may be useful in
training new employees and reminding older employees of hazards that can occur. It is recommended that all
employees be furnished with a copy of NPGA Safety Pamphlet 306-88, “LP-Gas Regulator and Valve Inspection
and Maintenance.”

Nature of Warnings Engineered Controls International, Inc. provides excess flow valves
It is recognized that warnings should be as brief as possible, but with a number of closing ratings. Engineered Controls International,
the factors involved in excess flow valve failures to perform are not Inc. obviously can take no responsibility for the proper selection or
simple. They need to be fully understood. If there is a simple warning, correct installation of any valve.
it would be:
Excess flow valves do not provide complete shut-off because there is
Make sure that the excess flow valve really closes when a bleed at the check to permit pressure equalization.
the flow exceeds normal transfer flow.
Causes of Failure to Close
This bulletin is not intended to be an exhaustive treatment of excess
Installers, LP-Gas plant managers and service personnel should be
flow valves, and certainly does not cover all safety practices that
aware that the excess flow valves may not close if these conditions
should be followed in installation, operation and maintenance of LP-
are present.
Gas systems which include excess flow valves.
1. The piping system restrictions (due to pipe length, branches,
Selection and Installation reduction in pipe size or number of other valves) decrease the
The selection of a given closing rating of an excess flow valve flow rate to less than the valve’s closing flow.
involves an analysis of the complete piping system and is beyond the
scope of this bulletin.
F

It is sufficient to say that an excess flow valve must be installed in


the correct direction and will close only if the flow of liquid or vapor
exceeds its designed closing rating. Many valves have been installed
with closing ratings considerably higher than any flow that could be
obtained by a downstream rupture in piping or hoses and thus give
none of the protection for which they are intended.

F4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Excess Flow Valves

2. The break or damage to the downstream line is not Because of these limitations, it is good industry practice to NOT
large enough to allow enough flow to close the valve. rely entirely on excess flow valves for protection. Installation of
emergency shut-off valves with remote controls is recommended in
addition to excess flow valves.

Testing
The National Propane Gas Association Safety Bulletin #113-78
states:

“In order to test an excess flow valve in a piping system, the


flow through the valve must be made to exceed the valve’s
closing rating. This testing should only be attempted by trained
personnel familiar with the process. If no one at the facility
3. A shut-off valve in the line is only partially open and will
has experience in proper testing, outside expert help should
not allow enough flow to close the excess flow valve.
be obtained. The exact procedure used may vary with the
installation, advisability of gas discharge and availability of
equipment.

In general, most testing makes use of the fact that excess flow valves
are “surge sensitive” and will close quicker under a sudden flow surge
than under steady flow. A sufficient surge can often be created by
using a quick open/close valve to control sudden, momentary flow
into a tank or piping section containing very low pressure. An audible
click from the excess flow valve (and corresponding stoppage of flow)
indicates its closure.

A test involving venting gas to the atmosphere is hazardous


and may be impractical, or illegal.

Any test of any excess flow valve will not prove that the valve will
close in an emergency situation, due to reasons cited before. This
test will only check the valve’s condition, and the flow rate sizing for
those test conditions.”
F
General Warning
4. LP-Gas pressure upstream of the excess flow valve,
particularly due to low temperature, is not high All ECII® products are mechanical devices that will eventually
enough to produce a closing flow rate. become inoperative due to wear, contaminants, corrosion and aging
of components made of materials such as metal and rubber.

The environment and conditions of use will determine the safe service
life of these products. Periodic testing at least once a year when tank
pressures are low and maintenance, as required, are essential.

Because ECII® products have a long and proven record of quality


and service, LP-Gas dealers may forget the hazards that can occur
because an excess flow valve is used beyond its safe service life.
Life of an excess flow valve is determined by the environment in
which it “lives”. The LPGas dealer knows better than anyone what
this environment is.

NOTE: There is a developing trend in state legislation and in proposed


national legislation to make the owners of products responsible for
replacing products before they reach the end of their safe useful
life. LPGas dealers should be aware of legislation which could effect
them.
5. Foreign matter
(such as welding
slag, scale or
sludge) is lodged
in the valve and
prevents closing.

F5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Troubleshooting Excess Flow Valve Installations

Periodical Inspections for Excess Flow Valves 2. Line Restriction Too Great
An excess flow valve installed
Excess flow valves should be tested and proven at the time of in a tank outlet will not close if
installation and at periodic intervals not to exceed one year. the line beyond it is reduced or
CAUTION: Testing an excess flow valve in the summer when if the flow is otherwise restricted
tank pressures are high will not prove that the same valve will by too many fittings or too
also function under low pressure conditions in the winter. Once long a run because the line is
a year testing should be conducted during the winter. incapable of passing the amount
of LP-Gas necessary to create
The test should include a simulated break in the line by the quick an “excess” flow. This condition
opening of a shut-off valve at the farthest point in the piping that should be corrected when testing
the excess flow valve is intended to protect. If the excess flow valve a system by simulating a break
closes under these conditions, it is reasonable to assume that it will at the farthest possible point and
close in the event of accidental breakage (clean break) of the piping replacing any restrictive hose,
at any point closer to the excess flow valve. pipe or fittings.

The National Propane Gas Association Safety Bulletin Number 113- 3. Improper Operating Practice
78 states:
A restriction can also be imposed
In order to test an excess flow valve in a piping system, the upon the excess flow valve by an
flow through the valve must be made to exceed the valve’s improperly opened valve at the
closing rating. This testing should only be attempted by trained tank outlet. The shutoff valve
personnel familiar with the process. If no one at the facility should be either fully opened
has experience in proper testing, outside expert help should or fully closed. If “throttled,” the
be obtained. The exact procedure used may vary with the valve could reduce the amount
installation, advisability of gas discharge and availability of of LP-Gas passing through the
equipment. excess flow valve in a sufficient
amount to keep it from closing.
In general, most testing makes use of the fact that excess flow valves Throttling operations should not
are “surge sensitive” and will close quicker under sudden flow surge be performed in the lines being
than under steady flow. A sufficient surge can often be created by protected by excess flow valves.
using a quick open/close valve to control sudden, momentary flow
F into a tank or piping section containing very low pressure. An audible
4. Improper Selection
click from the excess flow valve (and corresponding stoppage of flow) The many types of excess flow
indicates its closure. valves available are designed for
specific jobs. The excess flow
A test involving venting gas to the atmosphere is hazardous valve selected should remain
and may be impractical or illegal. open during normal flow but close
Any test of any excess flow valve will not prove that the valve will at “excess” flow. An inspection
close in an emergency situation, due to reasons cited before. This which simulates a line break
test will only check the valve’s condition and the flow rate sizing for prior to start-up operations will
those test conditions. determine if the proper valve has
been selected.
What prevents excess flow valves from closing when the line
breaks? 5. Tampering with Excess Flow Valves

Sometimes an operator, annoyed


For one or a combination of the following reasons, excess flow valves
with frequent closures of an
have been prevented from closing in emergencies:
excess flow valve with too low
a rating, has mutilated the valve
and forgotten to replace it with a
properly rated excess flow valve.
A pre-test of the system would
1. Not a Clean Break reveal this and allow the excess
flow valve to be replaced.

Hoses with a split or tear, and pipe


6. Impurities in the Line
lines not completely severed may
be emitting LP-Gas in an amount
insufficient to cause an “excess” Dirt, weld slag, broken drill
flow. The amount of LP-Gas which taps, and various other foreign
can escape through such breaks objects have been found jammed
may be even less than the flow between the valve disc and valve
during normal transfer service seat to prevent excess flow valves
and under these conditions the from closing. A pre-test of the
excess flow valve could not be system would also discover this.
expected to close.

F6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
The Limitations of Excess Check Valves for LP-Gas

Excess flow check valves have been of help in limiting gas loss in Where excess flow valves are installed, they should be checked
many incidents involving breakage of hoses and transfer piping. to see that:
Thus, they do provide a useful safety function in LP-Gas systems.
However, there have also been transfer system accidents where 1. They are installed in the correct direction — the arrow on the
excess flow valves have been ineffective in controlling gas loss due to valve indicates the shut-off direction.
a variety of conditions and to the inherent limitations of these valves.
This bulletin explains what protection excess flow valves can offer, 2. The flow rating on the valve is proper for the installation. The
points out conditions which can interfere with that protection, and rating must be above the normal system flow, but not higher than
offers suggestions for effective excess flow valve installation. necessary to prevent “nuisance” closing in normal conditions. If
the manufacturer’s catalog information is not sufficient, the valve
An excess flow valve is a protective device to help control the suppliers can provide sizing assistance.
discharge of product in the event of complete breakage of pipe lines
or hose rupture. However, an excess flow valve can only offer limited 3. In-line excess flow valves are installed so likely piping damage
protection from gas discharge, because it will only close under those will occur downstream of the valve and will not separate the
conditions which cause the flow through the valve to exceed its rated
valve from the upstream piping.
closing flow, and even when closed it necessarily allows some “bleed”
past the valve. When the excess flow valves can be examined separate from the
line (before the installation or if removed for system maintenance),
An excess flow valve is not designed to close and thus may not they should be checked to see that the parts are in good condition
provide protection, if any of the following conditions are present: and that the poppet can be pushed fully closed.
1. The piping system restrictions (due to pipe length, branches,
Testing of Excess Flow Valves
reduction in pipe size, or number of other valves) decrease the
flow rate to less than the valve’s closing flow. (Valve should be
In order to test an excess flow valve in a piping system, the flow
selected by closing flow rating — not just by pipe size). through the valve must be made to exceed the valve’s closing
rating.
2. The break or damage to the downstream line is not large enough to This testing should only be attempted by trained personnel
allow enough flow to close the valve. familiar with the process. If no one at the facility has experience
in proper testing, outside expert help should be obtained. The
3. A shut-off valve in the line is only partially open and will not allow exact procedure used may vary with the installation, advisability
enough flow to close the excess flow valve. of gas discharge, and availability of equipment.

4. LP-Gas pressure upstream of the excess flow valve, particularly In general, most testing makes use of the fact that excess flow
due to low temperature, is not high enough to produce a closing valves are “surge sensitive” and will close quicker under a sudden F
flow rate. flow surge than under steady flow. A sufficient surge can often
be created by using a quick-closing valve to control sudden,
5. Foreign matter (such as welding slag) is lodged in the valve and momentary flow into a tank or piping section containing very
prevents its closing. low pressure. An audible click from the excess flow valve (and
corresponding stoppage of flow) indicates its closure.
6. A buildup of process material (sludge), which may be found in
LPGas, may occur over a period of time and cause the valve to A test involving venting gas to the atmosphere is hazardous and
stick open. may be impractical, or illegal.

7. The piping break or damage occurs upstream of an in-line excess Any test of any excess flow valve will not prove that the valve
flow valve, so the escaping product is not passing through the will close in an emergency situation, due to reasons cited before.
valve. This test will only check the valve’s condition, and the flow rate
sizing for those test conditions.
8. The flow through the valve is in the wrong direction. (Excess flow
For additional information on excess flow valves and other means
valves only respond to flow in one direction.)
of
shut-off protection, contact Engineered Controls International,
[Link] excess flow valve has been damaged, or is otherwise not in
Inc. and refer to NFPA 58.
operating condition.

Because of these limitations of excess flow valves, they should not Prepared by
be relied upon as the only means of controlling the escape of product NATIONAL PROPANE GAS ASSOCIATION
in the event of piping damage. When possible, shut-off protection by The purpose of this bulletin is to set forth general safety practices for
quick closing valves, with shut-off controls accessible in spite of likely the installation, operation, and maintenance of LP-Gas equipment.
line damage, should be provided in addition to, or instead of excess It is not intended to be an exhaustive treatment of the subject, and
flow valves. should not be interpreted as precluding other procedures which
would enhance safe LP-Gas operations. The National Propane Gas
Association assumes no liability for reliance on the contents of this
bulletin.

F7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves

General Information How They Work


RegO® Excess Flow Valves have been designed, developed, and Excess flow valves permit the flow of liquid or vapor in either direction.
manufactured for a wide variety of industry needs for more than three This flow is controlled in only one direction (the direction of the arrow
decades. stamped on the valve). If the flow in that direction exceeds a
predetermined rate (shown in this catalog for each valve), the valve
Throughout the years, those concerned with installing and operating automatically closes.
bulk plant facilities have looked to RegO® products with confidence
for reliable, long-lasting valves as required by the National Fire The valve disc is held in the open position by a spring. When the
Protection Association (NFPA) Standards 58 and 59, as well as any flow creates a pressure drop across the valve disc that overcomes
state, provincial, and local regulations. the preset load on the spring, the valve disc moves to the closed
position. It remains closed until the force on both sides of the valve
It is a responsibility we have not taken lightly. RegO® products disc are approximately equal (a small bleed hole in the disc of each
continue to not only assess the most effective designs, but anticipate valve permits equalization), then the spring automatically reopens
and meet the industry’s changing requirements. Toward that goal, the valve. When a line is completely broken, the pressure cannot
RegO® products include over fifty different types and sizes of excess equalize and the excess flow valve remains closed until the line
flow valves (most of which are listed by Underwriters Laboratories) to is repaired. Because the bleed hole in each valve disc permits
meet the needs of the LP-Gas and anhydrous ammonia industries. equalization of pressure, excess flow valves do not provide a 100
percent type shut-off.
An Explanation and Warning
An excess flow valve is a spring-loaded check valve which will close Proper Installation
only when the flow of fluid through the valve generates sufficient force Since excess flow valves depend on flow in order to close, the line
to overcome the power of the spring holding it open. Each valve has downstream of the excess flow valve should be large enough not to
a closing rating in gallons per minute and CFH/air. excessively restrict the flow. If the piping is too small, unusually long or
restricted by too many elbows, tees and other fittings, consideration
should be given to the use of larger size pipe fittings.
The selection of a proper closing rating is critical. It requires a
technical understanding of the flow characteristics of the piping An excess flow valve in a pump suction line cannot be expected to
system, including restrictions of the piping and other valves and close in the case of a clean break in the line beyond the pump, as the
fittings downstream of the excess flow valve. pump constitutes too great a restriction, even if running.

Good piping practices dictate the selection of an excess flow valve


System designers and operating people must understand why an with a rated closing flow of approximately 50 percent greater than the
excess flow valve, which remains open in normal operations, may fail anticipated normal flow. This is important because valves which have
to close when an accident occurs.
F a rated closing flow very close to the normal flow may chatter or slug
closed when surges in the line occur during normal operation, or due
to the rapid opening of a control valve.
Warning: A downstream break in piping or hoses may not
result in sufficient flow to close the valve. All installations must be in accordance with NFPA Standards 58 and
59, as well as state, provincial and local regulations.

Cotter pin prevents loss of


spring retainer due to vibration
in service.

Spring retainer.

Stainless steel spring for


consistent closing flow, long
service life.

Welded for strength.

Precision machining.

Generous flow channels for


lowest pressure drop are
particularly important in pump
suction lines.

F8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Liquid or Vapor Service
1519C Series
Application
Designed for top mounting in storage tank manhole covers for liquid
or vapor applications. The tapped inlet allows for an optional 1” NPT
dip pipe connection to withdraw liquid from the top of the tank.

The 1519C4 is designed for installation in long line or branch piping


applications.

Features
• Precision machined

• Generous flow channels provide low pressure drop.

• Cotter pin prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

Materials
1519C2 1519C2
Body........................................................................................... Brass UL
®

Valve Poppet w/Stem................................................................. Brass


Spring.......................................................................... Stainless Steel
Guide.......................................................................................... Brass
Typical Installation
1519C4
Body........................................................................................... Brass
Valve Disc........................................................ Cadmium Plated Steel F
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel Manhole Cover
Guide................................................................................. Ductile Iron

PRODU 1519C4

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R
Ordering Information Typical Installation

Approximate Closing Flows


A B D
Inlet Outlet C Effective E Filling Liquid Vapor SCFH (Propane)
Connection Connection F. Wrench Hex Length Threaded End Connection (GPM
Part Number NPT NPT Flats (Approx.) to Port F. NPT Propane) 25 PSIG Inlet 100 PSIG Inlet
1519C2 1½” Male* 1” 2¼” 21⁄16” 211⁄16” 1” 25 5,000 8,800
1519C4 2” Female 2” 3” 49⁄16” - 2” 170 28,590 48,600

* 1” Female Dip Pipe Connection


** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.
F9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Liquid or Vapor Line Service
1519A Series, 1519B Series and A1519 Series
Application
Designed for top installation, in any position, in liquid or vapor service
lines. They are intended for long lines or branch piping where tank
mounted excess flow valves cannot suffice.

Features
• Precision machined.

• Generous flow channels provide low pressure drop.

• Cotter pin prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

Materials
1519A Series and 1519B Series
Body........................................................................................... Brass
Valve Poppet w/Stem................................................................. Brass 1519A2, 1519A3, 1519A4, 1519B4,
Spring.......................................................................... Stainless Steel A1519A2, A1519A4, A1519B4
Guide.......................................................................................... Brass UL
®

A1519 Series
Body................................................................ Cadmium Plated Steel
Valve Disc........................................................ Cadmium Plated Steel
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel
F Guide................................................................................. Ductile Iron

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

A1519A6

NOTE: Multiply flow rate by .94 to determine liquid butane flow


and by .90 to determine liquid anhydrous ammonia flow.
Typical Installation
Ordering Information
Approximate Closing Flows*
A B D
Brass Inlet Outlet C Effective Vapor SCFH (Propane)
or Connection Connection F. Wrench Hex Length Liquid
Part Number Steel NPT NPT Flats (Approx) (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
1519A2 Brass
1” 1” 1¾” 3 ⁄ ”
15 16 25 5,000 8,800
A1519A2 Steel
1519A3 1½” 1½” 2¼” 4” 60 11,500 20,200
Brass
1519A4
100 19,000 34,500
A1519A4 Steel
2” 2” 3” 49⁄16”
1519B4 Brass
133 27,700 50,300
A1519B4
Steel
A1519A6 3” 3” 4” 617⁄32” 225 45,000 82,000
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

F10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Liquid or Vapor 3272 Series, 3282 Series, 3292
Series, A3272 Series, A3282 Series, A3292 Series, 7574 and 12472
Application
Designed for liquid or vapor use for filling, withdrawal and vapor
equalizing in container or line applications. They are intended for long
lines or branch piping where tank-mounted excess flow valves are
inadequate.

Features
• Precision machined.

• Generous flow channels provide low pressure drop.

• Stainless steel spring provides consistent closing flow and long


service life.

UL
Materials
®

Typical Installation
Series 3272, 3282, 3292, 7574, 12472
Body........................................................................................... Brass
Seat Disc.................................................................................... Brass
Stem........................................................................................... Brass
Spring.......................................................................... Stainless Steel
Guide (12472 ONLY)................................................................. Plastic

Series A3272, A3282, A3292


Body................................................................ Cadmium Plated Steel
Seat Disc......................................................... Cadmium Plated Steel Container Service Pipe Line Service
Stem................................................................ Cadmium Plated Steel
Spring.......................................................................... Stainless Steel
Performance
60
50 Closing Flow Range
500 F
400
40 A- 12472 E - 3282A G Closing Flow Range
B- 3272E F - 3282B F 300 A - 3292A
30 C- 3272F G - 3282C
D- 3272G A3282C
B - 3292B
PRODU

10
A3272G
E 200 A3292B O
C - 7574

G
20

CT
RE
D

S
P ro p a ne F lo w (G P M )

P ro p a ne F lo w (G P M )

C
100

10

Y
10 90

NT
9 80 B
8 B 70 C
E

Y
7 AR A
WA R R
6 60 A
5 50
4
40
3
A
30

2 20

1
.07 .08 .09 .1 .2 .3 .4 .5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 910 10
Drop Across Valve (PSI) .07 .08 .09 .1 .2 .3 .4 .5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 9 10
Drop Across Valve (PSI)

Ordering Information NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

B D Approximate Closing Flow*


A Outlet C Effective
Vapor SCFH (Propane)
Part Brass or Inlet Connection Connection Wrench Length
Number Steel (M. NPT) (F. NPT) Hex Flats (Approx.) Liquid (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
12472 4 1,050 1,700
3272E 10 2,100 3,700
Brass
3272F ¾” ¾” 1⅜” 1⅜” 15 2,800 5,000
3272G
20 3,700 6,900
A3272G Steel
3282A 30 5,850 10,000
3282B Brass 40 7,600 13,600
1¼” 1¼” 2” 1 ⁄ ”
15 16
3282C
50 9,000 16,300
A3282C Steel
7574 90 15,200 28,100
1½” 1½” 2¼” 1¾”
7574L Brass 70 14,000 25,000
3292A
75 14,200 24,800
A3292A Steel
3292B Brass 2” 2” 2⅞” 1⅞”
100 18,100 32,700
A3292B
Steel
A3292C 122 22,100 37,600
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

F11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Container Service
A7537 Series, A7539 Series, A8523 and A8525
Application
Designed for mounting in threaded full or half couplings in container
installations. They may be used for filling, withdrawal or vapor
equalizing applications. The exceptionally low pressure drop makes
them ideal for pump suction lines. If a riser pipe to the vapor space is
used with these valves, the minimum inside diameter of the riser pipe
must be at least two times the valve thread size in order not to restrict
flow to the side inlet ports.

Features
• Precision machined.

• Generous flow channels provide low pressure drop minimizing


cavitation in pump suction lines.

• Cotter pin prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

• Separate models for installation in either half or full couplings. Typical Installation

Materials UL®

Body................................................................ Cadmium Plated Steel


Body (A7539 Series Only)................................................. Ductile Iron
Seat Disc......................................................... Cadmium Plated Steel
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel
Guide............................................................... Cadmium Plated Steel
F Half Coupling Full Coupling

PRODU

10
O
G

CT
RE

S
10

Y
NT
E
Y

AR A
WA R R

NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
Ordering Information
B Approximate Closing Flow*
For Use With A Outlet C D
Vapor SCFH (Propane)
Part This Type Inlet Connection Connection Wrench Hex Effective Length Liquid (GPM
Number Coupling M. NPT NPT Flats (Approx.) Propane) 25 PSIG Inlet 100 PSIG Inlet
A8523 Half ¾” ¾” Male 1⅛” 1¾” 15 5,170 8,800
A8525 Half 1¼” 1¼” Male 1¾” 2⅛” 35 12,540 21,560
A7537L4 Half
75 13,000 25,600
A7537L4F Full
A7537N4 Half 2” Male
2” and 2⅝“ 2½” 125 25,000 42,500
A7537N4F Full 1¼” Female
A7537P4 Half
150 30,500 52,000
A7537P4F Full
A7539R6 Half
150 32,100 55,500
A7539R6F Full
A7539T6 Half 3” Male
3” and 3¾” 3⅛” 200 39,400 68,300
A7539T6F Full 2” Female
A7539V6 Half
250 51,100 88,700
A7539V6F Full
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

F12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Vapor or Liquid
A2137 Series and 2139 Series
Application
UL®

Designed especially for filling, withdrawing or vapor equalizing in


half and full coupling installations. Ideal for container service where
welded-in dip pipes are not provided. For vapor use, mount in the
bottom opening with a threaded dip pipe. For liquid use, mount in the
top opening with a threaded dip pipe. These may also be installed in
pipe lines provided the connection is made to the male inlet thread
and not the female dip pipe connection.

Features
• Precision machined.

• Cotter pin helps prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

• Generous flow channels provide low pressure drop.


Typical Installations

Materials
A2137 Series
Body................................................................ Cadmium Plated Steel
Disc.................................................................. Cadmium Plated Steel Container Service Pipe Line Service
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel F
Guide............................................................... Cadmium Plated Steel

2139 Series
Body........................................................................................... Brass
Disc............................................................................................. Brass
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel
Guide.......................................................................................... Brass

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R
NOTE: Multiply flow rate by .94 to determine liquid butane flow
and by .90 to determine liquid anhydrous ammonia flow.

Ordering Information
Approximate Closing Flows***
A B D Vapor SCFH (Propane)
Inlet Connection Outlet Connection C Effective Length Liquid
Part Number NPT F. NPT Wrench Hex Flats (Approx.) (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
A2137 2” Male and 1¼” 50 10,000 17,000
2”* 27⁄16” 19⁄16”
A2137A Female 70 14,000 25,000
2139 3” Male and 2” 125 26,500 46,000
3”** 3½” 15⁄16”
2139A Female 160 32,700 57,200

* 11⁄4” F. NPT Dip Pipe Connection


** 2” F. NPT Dip Pipe Connection
*** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

F13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Flange Mounting in Container Service
A3500 Series and A4500 Series
Application
Designed for mounting in flanged tank connections with internal
UL®

threads in the bottom of a container. They may be used in filling,


withdrawal or vapor equalizing application. They provide high
flow capacity with low pressure drop to minimize pump inlet line
cavitation.

If a riser pipe to the vapor space is used with these excess flow
valves, the minimum inside diameter of the riser pipe must be at least
two times the valve thread size in order not to restrict flow to the side
inlet ports.

Flange mounted excess flow valves are readily accessible for


servicing and completely enclosed and protected in event of fire.
Because there is no direct connection between external piping and
the valve, stresses imposed on piping will not affect the excess flow
valve.

Features
• Precision machined.
• Generous flow channels provide low pressure drop minimizing
cavitation in pump suction lines.
• Cotter pin prevents loss of spring retainer due to vibration in
service.
• Stainless steel spring provides consistent closing flow and long
service life.
Materials
Body................................................................ Cadmium Plated Steel
F Seat Disc......................................................... Cadmium Plated Steel
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel PRODU

10
O

Guide............................................................... Cadmium Plated Steel

CT
RE

S
10

Y
Flanged Installation In Container

NT
E

Y
AR A
WA R R

NOTE: The opening in the tank flange should be machined with a


1⁄4”-45° chamfer at the outer edge. The thread should be tapped one
or two turns large as checked by a plug gauge. This and the undersize
thread on the valve should permit the valve to be installed so that its
outer face is at least flush with the outer edge of the flange.

The valve is screwed into this opening by fitting a 1⁄4” flat metal piece
into the slot and turning until hand tight. A lubricant may be used, but
a luting compound is not necessary since this joint does not have to
be gas tight.

If any difficulty is experienced in “making up” the valve to fit flush, as


indicated, the thread in the tank flange can be tapped.

Design and construction of tank and flange must be in accordance


with the appropriate section of the ASME Pressure Vessel Code.
A3400L4, A3400L6,
Ordering Information A3500L4, A3500R6,
Key A3500N4, A3500T6,
Approximate Closing Flows* No. Description A3500P4 A3500V6 A4500Y8
A C A Valve Size (NPT) 2” 3” 4”
Vapor SCFH (Propane)
Inlet B Effective D Liquid B Tank Opening 3½” 4½” 5½”
Part Connection For Thread Threaded (GPM 25 PSIG 100 PSIG
C Thickness (min.) 1” 1¼” 13⁄8”
Number NPT Installation (Approx.) End To Port Propane) Inlet Inlet
D Outside Diameter 6½” 8¼” 10”
A3500L4 75 13,000 22,500
E Pipe Thread (NPT) 2” 3” 4”
A3500N4 2” ¾” 115⁄16” 125 25,000 42,500
Bolt Circle Dia. 5” 65⁄8” 71⁄8”
A3500P4 150 30,500 52,000 F
Slotted Number of Bolt Holes 8 8 8
A3500R6 150 32,100 55,500
Body 5⁄8” -11
¾” - 10 ¾” - 10
A3500T6 3” 1” 19⁄16” 200 39,400 68,300 G Bolt Hole Thread
NC - 2 NC - 2 NC - 2
A3500V6 250 51,100 88,700 Bolt Hole Thread
A4500Y8 4” 11⁄16” 115⁄16” 500 89,000 154,000 H ¾” 1” 11⁄8”
(min. eff.)
NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
F14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valves for Liquid or Vapor Withdrawal
2723C and A8013D Series
Application
These valves are designed for bottom mounting in consumer storage UL
tanks for liquid service. They may also be top mounted for vapor ®

service. These valves are designed especially for use with RegO®
globe and angle valves.

Features
• 2723C provides a 3⁄4” dip pipe inlet connection for top-mounted
liquid or bottom-mounted vapor requirements.

• A8013D Series features a 2-position floating valve disc for faster,


more efficient container filing.

• Precision machined.

• Stainless steel spring provides consistent closing flow and long


service life.

• Generous flow channels provide low pressure drop.

Materials A8013D

A8013D Series
Body................................................................ Cadmium Plated Steel
Disc.............................................................................. Stainless Steel
Stem............................................................................ Stainless Steel
Spring.......................................................................... Stainless Steel
Guide............................................................... Cadmium Plated Steel
Insert........................................................................... Stainless Steel
F
2723C
Body........................................................................................... Brass
Valve Poppet.............................................................................. Brass
Retainer...................................................................................... Brass
Spring.......................................................................... Stainless Steel

2723C

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
A. B. D. Approximate Closing Flow**
Inlet Outlet C. Effective E.
Vapor SCFH (Propane)
Connection Connection Wrench Hex Length Threaded Liquid
Part Number M. NPT NPT Flats (Approx.) End To Port (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
A8013D ¾” ⁄ ”
9 16 39
8,700 14,700
A8013DA 1¼” 1” 1⅞” 21⁄32” - 44
A8013DB 1¼” 11⁄16” 55 10,900 19,300
2723C 1¼” ¾” 111⁄16” 11⁄4” 33⁄16” 20 3,900 6,900
* 3⁄4” F. NPT Dip Pipe Connection
** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

F15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Excess Flow Valve for Pressure Gauges
2884D
Application
Designed for container use in pressure gauge installations to minimize
UL
®

excess gas discharge in the event the pressure gauge is sheared. A E


suitable shut-off valve should be installed between this valve and the A
pressure gauge to allow convenient gauge replacement.

Features D
C
• Precision machined.
2884D B
• Suitable for use with all ¼” [Link] pressure gauges.
Materials PRODU

10
O

CT
RE
Body........................................................................................... Brass

S
Valve . ........................................................................................ Brass

10

Y
NT
E
Spring.......................................................................... Stainless Steel

Y
AR A
Ordering Information WA R R
Pin............................................................................... Stainless Steel

Approximate Closing Flow*


Vapor SCFH (Propane)
A. B. D. E.
Part Inlet Connection Outlet Connection C. Effective Length Threaded End To Liquid 25 PSIG 100 PSIG
Number M. NPT F. NPT Wrench Hex Flats (Approx.) Port (GPM Propane) Inlet Inlet
2884D ¾” ¼” 11⁄16” 11⁄4” ⁄ ”
11 16 N/A 60 110

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.

Excess Flow Valve for DOT Cylinders


3199W
F
Application
UL
Designed for use on portable systems with vapor or liquid including ®

torches, heaters, lead melting burners, tar and asphalt burners,


wallpaper steamers and other applications involving portable DOT
cylinders. The POL inlet attaches directly to the cylinder valve and the
A C
outlet mounts to the regulator. B

3199W
Features
• Integral ball check design.
D
• Machined groove designed to break-off and allow excess flow valve Groove
ball to close.
PRODU

10
O
G

CT
RE

Typical Installation
S

Materials
10

Y
NT

E
Y

AR A
WA RR
Body........................................................................................... Brass NOTE:
Nut.............................................................................................. Brass No protection is afforded should break-off occur downstream of the
Bell.............................................................................. Stainless Steel groove. Also, restrictions introduced by the regulator may prevent
Spring.......................................................................... Stainless Steel closing of the valve due to limited flow capacity. The valve’s purpose
Retainer Spring........................................................... Stainless Steel is to protect the cylinder valve outlet should the regulator be broken
Retainer...................................................................................... Brass off of its connection (at the groove), in which case it will close. It must
not be depended upon to protect against breaks downstream of the
Ordering Information regulator.

Approximate Closing Flow*


Vapor SCFH (Propane)
B. C. D.
Part A. Outlet Wrench Hex Effective Length Liquid
Number Inlet Connection Connection Flats (Approx.) (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
3199W Male POL ¼” ⅞” 11⁄16” .95 265 500
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.

F16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Chek-Lok® Excess Flow Valves
Designed to provide a convenient means of withdrawing liquid from The Chek-Lok® permits one transfer shut-off valve with an adapter to
stationary containers prior to moving the container. be used interchangeably on a number of tanks. With a Chek-Lok® on
each tank and a high capacity RegO® 7550P Series transfer valve
NFPA Pamphlet 58 standards require: 1) containers with 125 gallons
and adapter on all your service and delivery trucks – the need for
water capacity, or more, have a connection for liquid evacuation which
individual transfer valves is eliminated. This provides a substantial
is at least 3/4” NPT, and 2) containers designed for stationary use, have
savings without sacrificing safety.
no more propane than 5% of their water capacity in liquid form during
transportation. These rules apply to containers manufactured after
July 1, 1961.
Chek-Lok® Operation
Instructions to Open Chek-Lok® Connecting the
1 Loosen cap to vent any accumulated LP-Gas from the Chek-Lok. 7590U or 7591U
After venting stops, remove the cap. If venting does not stop,
retighten the cap and use other approved means to withdraw liquid Chek-Lok®
from the container.
NOTE: Use a suitable size wrench when removing the cap and
adapter from the Chek-Lok. Do not allow the Chek-Lok to un- 7550P Angle Valve
thread from the tank during removal. When necessary, use a
second wrench to secure the Chek-Lok in position.

2 Before beginning withdrawal, securely connect an ECII® 7550P


angle valve or suitable shut-off valve to the adapter. Fully open the
shut-off valve – the valve’s handwheel must be fully opened before
connecting adapter to tank. 7590U-10 Adapter

3 Completely thread the adapter and shut-off valve assembly onto


the Chek-Lok by turning adapter’s coupling nut clockwise until it
is tight. Immediately close the shut-off valve. Listen for an audible
click to signal that the Chek-Lok has opened and is actuated for 7590U or 7591U Chek-Lok®
liquid withdrawal. The flow can now be controlled by the transfer
valve.

4 Check the coupling nut and adapter assembly for leaks using a Connecting the
suitable leak detection solution.
7572FC or 7580FC F
If the Chek-Lok fails to open after following this procedure, the
pressure downstream of the shut-off valve should be increased Chek-Lok®
to equalize pressure in the Chek-Lok. It is simple to equalize
pressures using vapor from either the vapor return valve or service
valve, or from a hose end valve connected to the delivery truck. 7550P Angle Valve

Instructions to Close Chek-Lok®


1 To re-lock the Chek-Lok, container pressure must be in excess of
35 PSIG. Close shut-off valve and disconnect the hose or piping.

2 Open shut-off valve fully. Liquid discharging to the atmosphere 7572-14A Adapter
should cause the excess flow feature of the Chek-Lok to close,
provided tank pressure is 35 PSIG or more.
If, for any reason, the excess flow valve does not close, the shut-
off valve must be closed immediately and must not be removed
until the system can be evacuated and the unit repaired. 7572FC or 7580FC Chek-Lok®

3 After the excess flow valve closes, remove the Adapter and Shut-
Off Valve Assembly.
In the absence of a 7550P transfer valve, a 3⁄4” A7505A Globe Valve
or A7506AP Angle Valve may be used. Follow the above procedures
4 Clean face of Chek-Lok and install the Cap with a gasket.
using the 7572C-15A adapter instead of the 7572C-14A. Use an ECII
IMPORTANT: Only use the proper Chek-Lok Cap. Do not use a
standard pipe cap. 7550P without an adapter in an emergency only.

CAUTION: Always wear approved protective gloves when working with the Chek-Lok®.Do not vent LP-Gas near possible source of ignition.

Chek-Lok® Mounting
Chek-Lok® Valves may be either top mounted with a dip tube
or bottom mounted. For bottom mounting, it is preferable to
position the coupling in the head or slightly off of the bottom.
This helps prevent the accumulation of sludge, etc. around the
valve which could affect the proper operation of the excess
flow valve.

F17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Chek-Lok® Excess Flow Valves
7590U and 7591U Series
Application 7590U with Cap

Chek-Lok® Excess Flow Valves are designed to provide a convenient PRODU

10
O
means of withdrawing liquid from stationary containers prior to moving

CT
RE
the container. The Chek-Lok® permits one transfer shut-off valve with

S
an adapter to be used interchangeably on a number of tanks. UL

10

Y
NT
® E

Y
AR A
WA R R
The 7590U and 7591U Chek-Loks® are also designed for use on
permanent installations provided the excess flow valve is sized
properly for the system and piping. NOTE: In some cases, it may
be necessary to use an in-line excess flow valve to protect the
downstream piping. This valve is not recommended for use as a liquid Cap C
source for pumps. Gasket

Features
B
• Extra strength connection between body and adapter provides Chek-Lok ®

increased strength. A

• Weep hole in cap provides indicator to verify Chek-Lok® is closed


before cap removal.

• Heavy duty brass cap requires at least 31/2 full turns for removal.
Materials
• O-ring seal on adapter provides a gas tight seal before the adapter
opens the equalizing stem. Body........................................................................................... Brass
Stem........................................................................................... Brass
• Eliminates need for individual transfer valves at each container. Spring.......................................................................... Stainless Steel
Seals....................................................................... Sunthetic Rubber
• UL listed. Valve Poppet.............................................................................. Brass
Gasket........................................................................................ Nylon

F C.
Body Wrench Hex
B.
Approximate
C.
Cap Wrench Hex
Approximate Closing
Flow, Liquid
Chek-Lok® Number Inlet Connection Outlet Connection Flats Effective Length Flats GPM (Propane)*
7590U ¾” M. NPT 115⁄8” 17⁄16” 20
15⁄8” UNF 15⁄16”
7591U 1¼” M. NPT 1¾” 111⁄16” 35
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up, and slightly less when installed with outlet down.
Note: Multiply flow rate by .94 to determine liquid butane flow.

Chek-Lok® Liquid Evacuation Adapter for 7590U and 7591U Valves


7590U-20
Application
Designed specifically for use with RegO® 7590U and 7591U Chek-
Lok® Excess Flow Valves. Adapter’s operating handle opens and UL
®
closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow
through Chek-Lok® valve when installing or removing adapter. Use
of RegO® adapter ensures proper connections and opening of the
check mechanism.

Features
• Built in nylon gasket provides a gas tight seal.

• Adapter can be installed without depressing the equalizing stem of B


the Chek-Lok®. 7590U-20

• Design eliminates the need to slug excess flow feature of Chek- PRODU

10
O
Lok® when removing the adapter.
G

CT
RE

S
10

A
• Built in bleeder valve allows controlled discharge of liquid before
NT

E
Y

AR A
WA R R
removing the adapter.
Ordering Information
Adapter Number Inlet Connection Outlet Connection A Wrench Hex Flats B Approximate Length
7590U-20 1⅝” F. NPT ¾” F. NPT 1¾” F. NPT 4⅛” F. NPT

F18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Union Style Adapters for 7590U and 7591U Valves

The 7590U-10 adapter must be used to connect to the 7590U and


7591U Chek-Lok. This insures a proper connection to open the check
mechanism. A built in nylon gasket provides a gas tight seal.

UL
PRODU

10
O

CT
RE

S
®

10

Y
NT
E

Y
AR
WA R RA

Ordering Information
Adapter Inlet Outlet A. Wrench Hex B. Approximate
Number Connection Connection Flats Length
7590U-10 1⅝” UNF ¾” F. NPT 1¾” 113⁄16” 7590U-10

Adapters for 7572FC and 7580FC Valves

These adapters must be used to connect to the 7572FC and 7580FC


Chek Loks to open the check mechanism properly. A built in nylon 7572C-14A
gasket provides a gas tight seal. For Transfer
Valves
PRODU

10
O
G

CT
RE

UL
10

Y
NT

E
Y

AR A
WA R R ®

Ordering Information F
B.
Approximate
7572C-15A
Adapter Inlet Outlet A. Wrench Hex Effective
For Globe and
Number Connection Connection Flats Length
Angle Valves

7572C-14A ¾” F. NPT 1”
¾” M. NPT 1⅜”
7572C-15A ¾” M. NPT ¼”

F19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Double-Check Filler Valves
General Information
RegO® Double-Check Filler Valves incorporate a resilient upper
check valve, normally designated as a filler valve, and a lower check
valve, commonly called a back pressure check valve. Available in a Seal cap made of tough, resilient
range of sizes to cover virtually all LP-Gas storage containers, these molded plastic. Protects threads
valves are UL listed and meet NFPA standards, as well as other and internal working parts. Caps
safety requirements. are designed to contain normal tank
pressures, and must be kept on valves
Flow of liquid into the storage container opens both check valves. at all times.
When flow stops, they both are designed to close automatically to Long-wearing gasket permits hand-tight
permit the operator to disconnect the hose coupling. The automatic connection of cap and hose coupling.
closing action also helps prevent the discharge of container contents
in the event of hose failure. The lower back pressure check affords Safety groove is designed to shear
extra protection by restricting the discharge if the upper check fails to below the ACME thread, leaving the
function properly due to accidents or other causes. valve seats closed and unaffected if the
delivery truck pulls away with the hose
connected.
The double back check construction allows emergency inspection, Seat disc of special synthetic
repair, or replacement of the upper fill assembly without removing composition is extra thick for longer
product from the container. When the upper filler valve body is life.
removed, the lower back check valve provides a seal, permitting only Valve guide is precision machined to
some leakage, allowing a new upper filler valve body to be installed. assure positive seal.
Spare Gasket Ordering Information Exclusive swing-away lower back check
valve for extra fast filling is provided on
ACME Part Number
Models 6579 and 6587. Differs from
1¼” A2797-20R conventional design by swiveling to a
1¾” A2697-20R vertical position when opened.
2¼” A3184-8R
3¼” A3194-8R

Double-Check Filler Valves for Large Motor Fuel and ASME Tanks
6579 Series and 7579 Series
F Application Materials

Designed to provide fast filling of large motor fuel and ASME domestic Upper Body................................................................................ Brass
tanks. The 6579 Series incorporates a swing-away lower check which Lower Body................................................................................ Brass
greatly reduces pressure drop across the valve. This lower pressure Springs........................................................................ Stainless Steel
drop promotes faster filling rates and greater efficiency resulting in Washer and Seat Disc.............................................. Synthetic Rubber
more profitable operations. Cap............................................................................................ Plastic

UL
PRODU

10
O

Features
G

CT

7579P A
RE

®
10

Y
NT

E
Y

AR A
WA R R
• Double back check provides added system protection. A D C

• Upper filler valve assembly can be easily replaced without


D C
evacuating the container. B

• Both checks are spring actuated for quick, precise closure when
flow into the valve stops or reverses. B 7579

• 6579 Series swing-away check promotes faster filling for more 6579
profitable operations.

• Specify RegO® Filler Valves on all your original tank purchases to


insure quality and dependable performance.

6579
Ordering Information
Part Number A. B. D. Propane Liquid Capacity at Various Differential Pressures (GPM)
C.
ACME Tank Effective
Wrench 5 PSIG 10 PSIG 25 PSIG 50 PSIG 75 PSIG
Cap Only Cap, Chain and Ring Hose Connection Length
Hex Flats
Connection M. NPT (Approx.)
7579 7579C 1¼” 50 70 111 157 192
7579P - 1¼” 37 52 82 116 142
1¾” 1⅞”
6579** 6579C** 1¼” 78 110 174 246 301

* Incorporates ¾ F. NPT dip pipe connection


** Swing-away lower back check valve design for higher filling rate. NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

F20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Double Check Filler Valves for Forklift, Motor Fuel and RV Tanks
7647 Series
Application
Designed to provide fast filling of forklift, motor fuel, and recreational UL
®

vehicle tanks. Lanyard and Cap

Features
• Resilient seat disc in lower check designed to provide a gas tight
seal without leakage.

• Double back check provides added system protection.

• 7647SA has 30º angle on hose connection. Makes connection and


disconnection easier for certain engine fuel applications.

• Large 13⁄4” wrench flats on 7647SC allow use of socket wrench for
easy installation.

• Specify RegO® Filler Valves on all your original tank purchases to 7647SC
insure quality and dependable performance.

Materials UL
®

Upper Body................................................................................ Brass


Lower Body................................................................................ Brass
Springs........................................................................ Stainless Steel
Washer and Seat Discs............................. Resilient Synthetic Rubber
Cap............................................................................................ Plastic

7647SA

7647DC

UL
®

PRODU

10
O
G

CT
RE

7647HF
10

Y
NT

E
Y

AR A
WA R R
7647H

Ordering Information
Part Number Propane Liquid Capacity at Various Differential Pressures (GPM)***
A B C D
w/Lanyard Hose Tank Connection Wrench Effective Length
Basic and Cap Connection M. NPT Flats (Approx.) 10 PSIG 20 PSIG 30 PSIG 40 PSIG 50 PSIG
7647H - ½” F. NPT 27⁄16”
7647HF - ½” SAE Flare 2⅝”
1¾” ACME & 1½”
- 7647DC ¾” 3” 14 20 24 27 50
F. POL
- 7647SA** 31⁄16”
1¾” ACME
- 7647SC* 1¾” 2¼”*
* Large 13⁄4” hex wrench flats.
** 30˚ angle on 1-1/4” ACME hose connection.
*** Multiply flow rate by .94 to determine liquid butane capacity.

F21
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Double Check Filler Valves for Delivery Truck Tanks and
Large Storage Containers 7579S, 6587EC and 3197C

Application
UL
Designed to provide fast filling of bobtails, transports and large bulk ®

storage tanks.

The 6587EC incorporates a swing-away lower check which greatly


reduces pressure drop across the valve. This lower pressure drop
promotes faster filling rates and greater efficiency resulting in more
profitable operations.

Features
• Double back check provides added system protection.

• Upper filler valve assembly can be easily replaced without


7579S
evacuating the container.

• Both checks are spring actuated for quick, precise closure when
flow into the valve stops or reverses.

• 6587EC swing-away check promotes up to 65% faster filling rates


for more profitable operations. Faster filling rates add longer pump
life by reducing chances of cavitation.

• Specify RegO® Filler Valves on all your original tank purchases to


insure quality and dependable performance.

F Materials
Upper Body................................................................................ Brass
Lower Body (7579S and 6587EC).............................................. Brass 6587EC
Lower Body (3197C).................................................................. Brass
Springs........................................................................ Stainless Steel
Washer and Seat Discs............................................ Synthetic Rubber
Cap (6587EC and 3197C).......................................................... Brass
Cap (7579S).............................................................................. Plastic

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

3197C

Ordering Information
A. B. D. Propane Liquid Capacity at Various Differential Pressures (GPM)
C.
Part ACME Tank Effective
Wrench 5 10 25 50 75
Number Hose Connection Length
Hex Flats PSIG PSIG PSIG PSIG PSIG
Connection M. NPT (Approx.)
7579S 1¾” 1½” 2” 211⁄16” 44 62 98 139 170
6587EC* 2¼“ 2” 2⅞” 4⁄”
38 92 130 206 291 356
3197C 3¼” 3” 4” 61⁄2” 148 210 332 470 575

* Swing-away lower back check valve design for higher filling rates.
NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

F22
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Single Check Filler Valves for Storage Tanks with Supplementary
Back Check Valves 3174C, 3194C and 6584C
Application
Designed for use with RegO® Back Check Valves to provide
fast filling of bulk storage tanks. Also may be used as a spare or
replacement part.

These single check filler valves must never be installed directly into
container couplings. They must be used with the appropriate back
check valve to comply with NFPA Pamphlet #58.

Features
• Specifically for use with RegO® Back Check Valves.
3174C
• 6584C stem assembly reduces turbulence during filling and
promotes higher filling rates.

• Specify RegO® Filler Valves on all your original tank purchases to


insure quality and dependable performance.

Materials
Upper Body................................................................................ Brass
Lower Body ............................................................................... Brass
Springs........................................................................ Stainless Steel
Washer and Seat Discs............................................ Synthetic Rubber
Cap (3194C, 6584C).................................................................. Brass
Cap (3174C).............................................................................. Plastic

PRODU

10 F
O
G

CT
RE

UL
10

Y
NT

E
Y

AR A
WA R R ®

3194C, 6584C
Ordering Information
Propane Liquid Capacity at Various
Differential Pressures (GPM)
Outlet For Use With
ACME Hose Connection M. Wrench Hex Back Check
Part Number Connection NPT Flats 5 PSIG 10 PSIG 25 PSIG 50 PSIG Valve:
3174C 1¾” 1¼” 1¾” 23 33 52 74 3176
6584C* 2¼” 2” 2⅜” 156 220 348 492 A3186
3194C 3¼” 3” 3½” 147 208 329 465 A3196

* Stem Assembly designed for higher filling rates.


NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

Seal cap made of tough, resilient molded


plastic. Protects threads and internal working
Vapor Equalizing Valves parts. Caps are designed to contain normal
tank pressures, and must be kept on valves
General Information at all times.
RegO® Vapor Equalizing Valves consist of an upper back check valve Long-wearing gasket permits hand-tight
and lower excess flow valve. In the closed position, the attachment of connection of cap and hose coupling.
a vapor hose coupling with its projecting nozzle, opens the back check
valve to permit flow in either direction. The lower excess flow valve is Seat disc of special synthetic composition is
designed to close automatically when flow out of the container being extra thick for longer life.
filled exceeds the rated capacity. The valve closes automatically when
the coupling is removed. Like the double-check filler valves, the vapor Valve guide is precision machined to assure
equalizing valves utilize a two-piece body construction. The lower positive seal.
excess flow valve will permit some leakage when the upper back
check valve is removed for emergency repairs or replacement. Spare Gasket Ordering Information
RegO Vapor Equalizing Valves are designed for use in both ASME
® ACME Part Number
and DOT containers. 1¼” A2797-20R
1¾” A2697-20R

F23
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Double Check Vapor Equalizing Valves for ASME and DOT
Containers 7573 Series and 3183AC
Application
Designed to facilitate loading operations by providing equalization of
pressures in the supply and storage containers. The supplementary PRODU

10
O
excess flow valve closes when the flow from the container being filled

CT
RE

S
exceeds a predetermined rate.

10

Y
NT
E

Y
AR A
WA R R
The 7573 Series is designed for use in bulk delivery systems and
motor fuel containers. The 3183AC is designed for use in delivery
trucks and other large containers.

Features UL ®

• Double check provides added system protection.

• Upper back check valve can be easily replaced without evacuating 7573 Series
the container Materials
• Specify RegO® Vapor Equalizing Valves on all your original tank Body ........................................................................................... Brass
purchases to insure quality and dependable performance.
Spring .......................................................................... Stainless Steel
Upper Check Seat Disc .............................................Synthetic Rubber
Seals ........................................................................ Synthetic Rubber
Cap ............................................................................................ Plastic
Ordering Information
Part Number B. Approx. Closing Flow
A. D.
Tank C. at 100 PSIG Inlet
ACME Hose Effective Length
Basic W/ Chain & Cap Connection M. Wrench Hex Flats (Approx.)
Pressure
Connection
NPT (SCFH/Propane)
7573D 7573DC 1¼” ¾” 1¼” 21⁄16” 4,100
- 3183AC 1¾” 1¼” 2” 3⁄ ”
1 16
10,000

F
Single Check Vapor Equalizing Valves for ASME and DOT
Containers with Supplementary Excess Flow Valves
Application
Designed for use with RegO® Excess Flow Valves to facilitate loading
operations by providing equalization of pressures in the supply and
storage containers. Also may be used as a spare or replacement part.
These vapor equalizing valves must never be installed directly into
container couplings. They must be used with the appropriate excess
flow valve to comply with NFPA Pamphlet #58.

Features
• Specifically for use with RegO® Excess Flow Valves.

• Specify RegO® Vapor Equalizing Valves on all your original tank


purchases to insure quality and dependable performance.

Materials
PRODU

10
O
Body............................................................................................ Brass 3170
G

CT
RE

Spring............................................................................ Stainless Steel


S

Seat Disc....................................................................Synthetic Rubber


10

UL
NT

E
Y

AR A
Seal............................................................................Synthetic Rubber ® WA R R
Cap..............................................................................................Plastic

Ordering Information
Part Number A. B. C. D.
Inlet Outlet Wrench Hex Effective Length Approximate Closing Flow at 100 PSIG For Use With Excess
Basic With Cap & Chain Connection Connection Flats (Approx.) Inlet Pressure (SCFH/Propane Vapor) Flow Valve:
3170 - 1¼” ¾” 1¼” 19⁄16” 7.600 3272E
- 3180C 1¾” 1¼” 1¾” 111⁄16” 10,000 3282A

F24
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Back Pressure Check Valves
General Information Metal-to-metal seats will allow slight leakage after closure. These
valves will restrict the escape of container contents in the event of
RegO® Back Pressure Check Valves are designed to allow flow in accidental breakage of the piping or fittings.
one direction only. The check, normally held in the closed position by
a spring, precludes the possibility of flow out of the container. When
flow starts into the container, the pressure overcomes the force of
the spring to open the check. When the flow stops or reverses, the
check closes.

Back Pressure Valves for Container or Line Applications


3146 Series, 3176 Series, A3186, A3187S, A3196, and A3276BC
Application
Designed to provide protection of a container opening when desired
flow is always into the vessel. May be used in line applications where
flow must be limited to one direction.

When used with the appropriate single check filler valve, the
combination forms a double check filler valve suitable for use in filling
of bulk storage tanks.

Features
• Generous flow channels for low pressure drop.

• Heavy-duty construction for long service life.

• Soft seat valves have synthetic rubber seat disc for positive seals.
3146 Series, 3176 Series, A3186, A3196
Materials
Body (3146, 3146S, 3176) ...................................................... Brass
Body (all others) ............................................ Cadmium Plated Steel
Disc (3146, 3146S, 3176) . ...................................................... Brass
F
Disc (all others) ............................................. Cadmium Plated Steel
Stem (3146, 3146S, 3176) ...................................................... Brass
Stem (A3146, A3196, A3276BC) ............................... Stainless Steel
Stem (A3176, A3186) .................................... Cadmium Plated Steel
Spring ........................................................................ Stainless Steel
Seat Disc (3146S, A3276BC) ................................ Synthetic Rubber

UL
®
PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information A3187S A3276BC

A B D Propane Liquid Capacity at various differential


Part Number C
Inlet Outlet Effective pressures (GPM)
Wrench Hex
Connection Connection Length
Brass Steel Flats 5 PSIG 10 PSIG 25 PSIG 50 PSIG
F. NPT M. NPT (approx.)
3146 A3146
3/4” 3/4” 1 3/8” 1 15/16” 11 16 25 36
3146S*
3176 A3176 1 3/8” 28 40 63 89
1 1/4” 1 1/4” 2”
A3276BC* 2 1/2” 32 45 73 103
A3186 2” 2” 2 7/8” 2 7/16” 124 175 276 391
2” M & 2” M &
A3187S* 2 3/8” 4 3/8” 60 110 225 350
1 1/4” F 1 1/4” F
A3196 3” 3” 4” 3 15/16” 297 420 664 939
*Soft seat version.
NOTE: Multiply flow rate by .94 to determine liquid butane capacity and by .90 to determine liquid anhydrous ammonia capacity.
F25
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Swing-Away Back Pressure Check Valves for Container or Line
Applications 6586D and A6586D
Application Materials
Designed to provide protection of a container opening when desired Body (6586D) ............................................................................. Brass
flow is always into the vessel. May also be used in the line applications Body (A6586D) ............................................................................ Steel
where flow must be limited to one direction. Disc (6586D)............................................................................... Brass
Disc (A6586D) ............................................................. Stainless Steel
When used with the appropriate single check filler valve, the Stem Assembly . ........................................................... Stainless Steel
combination forms a double check filler valve suitable for use in filling Spring .......................................................................... Stainless Steel
of bulk storage tanks. Screw ........................................................................... Stainless Steel

The swing-away check offers more efficient flow rates than


conventional designs. It swivels open vertically to reduce pressure UL
®

drop across the valve and improves flow rates.

Features
PRODU

10
G O

CT
• Swing-away check design offers faster flow rates.
RE

S
10

Y
E NT
Y

AR A
• Heavy-duty construction for long service life. WA R R

6586D
Ordering Information
Part Number Propane Liquid Capacity at Various Differential Pressures (GPM)
A. B. C. D.
Inlet Connection Outlet Connection Wrench Effective Length
Brass Steel F. NPT M. NPT Hex Flats (Approx.) 5 PSIG 10 PSIG 25 PSIG 50 PSIG
6586D A6586D 2” 2” 2⅞” 27⁄16” 190 270 420 600
NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

F
Back Pressure Check Valves for Flanged Installation
A3400L4 and A3400L6
Application
Designed to provide high flow capacity and allow more efficient tank
filling than conventional designs. The unobstructed throat area
reduces flow turbulence through the valve, thereby reducing pressure
drop. Large flow channels and spacious side ports assure ample
capacity for the most demanding high capacity filling operations.

The valve is designed for installation in internally threaded flanges in


container bottoms.

Features
• Speeds up filling operations in bulk tanks.
• All steel and stainless steel construction assures long service life.
Materials A3400L6

Body ................................................................ Cadmium Plated Steel PRODU

10
O
Stem ............................................................................ Stainless Steel
G

CT
RE

UL
S

Spring .......................................................................... Stainless Steel


10

Disc ................................................................. Cadmium Plated Steel


®
NT

E
Y

AR A
WA R R
Guide ............................................................................ Stainless Steel
Roll Pin ........................................................................ Stainless Steel

Ordering Information
A. B. D. Propane Liquid Capacity at Various Differential Pressures (GPM)
Flange Connection Wrench Hex C. Threaded End
Part Number M. NPT Flats Overall Length To Port 5 PSIG 10 PSIG 25 PSIG 50 PSIG
A3400L4 2” 5¼” 15⁄16” 223 316 500 707
Slotted
A3400L6 3” 59⁄32” 19⁄16” 424 600 949 1342

NOTE: For installation in flange tank connections with internal threads, see the “Flanged Installation in Container” section under “Excess Flow Valves.”
Multiply flow rate by .94 to determine liquid butane capacity and by .90 for liquid anhydrous ammonia capacity.

F26
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Warning Notice

The following warning information, Part Number 903-500, is included These adhesive warning labels are intended for application as close
with each shipment of Excess Flow, Check, Filler and Vapor as possible to the Chek-Lok® once the Chek-Lok® is installed.
Equalizing Valves to the first purchaser of the product from the
factory. The basic information contained on the label is intended for the
benefit of the user of the Chek-Lok® and is not intended to be an “all-
This information is intended to be forwarded throughout the product inclusive” product warning.
distribution chain. Additional copies are available from Engineered
Controls International, Inc. and Authorized Product Distributors. This label is printed on a heavy duty material with pressure sensitive
adhesive backing. The ultra-violet ink stands up well when exposed
to the environment.

Part Number Description


7572-400 Adhesive Warning Label

DANGER WARNING
LP-GAS IS EXTREMELY

F
FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL,
OR HEAR ESCAPING GAS... EVACUATE AREA IMMEDIATELY! CALL YOUR
LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT
STORE IN BUILDING OR ENCLOSED AREA. DO NOT USE ON HOT AIR
BALLOONS OR AIRCRAFT.
CAUTION!
Use this CHECK-LOK ® connection only for liquid evacuation before moving
tank in accordance with NFPA Pamphlet 58, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA
02269. Read and follow ECII ® product instruction number 7572FA-301.
DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL.
DO NOT FILL THIS CONTAINER UNLESS THIS LABEL IS READABLE.
ADDITIONAL SAFETY INFORMATION IS AVAILABLE FROM

Engineer ed Contr ol s Printed in U.S.A. 03-0994-1189


® International, Inc. Part No. 7572-400
100 RegO Drive PO Box 247 Elon College, NC 27244 USA Phone (336) 449-7707 Fax (336) 449-6594 www .regoproducts.c om

F27
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cross Reference by Part Number
12472................................................................................................ F11 A3292C............................................................................................... F11
A1519A2..............................................................................................F10 A3400L4..............................................................................................F26
1519A2..............................................................................................F10 A3400L6..............................................................................................F26
1519A3..............................................................................................F10 A3500L4..............................................................................................F14
A1519A4..............................................................................................F10 A3500N4.............................................................................................F14
1519A4..............................................................................................F10 A3500P4..............................................................................................F14
A1519A6..............................................................................................F10 A3500R6.............................................................................................F14
A1519B4..............................................................................................F10 A3500T6..............................................................................................F14
1519B4..............................................................................................F10 A3500V6..............................................................................................F14
1519C2...............................................................................................F9 6579..................................................................................................F20
1519C4...............................................................................................F9 6584C...............................................................................................F23
A2137..................................................................................................F13 A6586D...............................................................................................F26
A2137A................................................................................................F13 6586D...............................................................................................F26
2139..................................................................................................F13 6587EC.............................................................................................F22
2139A................................................................................................F13 A7537L4..............................................................................................F12
A2697-20R..........................................................................................F20 A7537L4F............................................................................................F12
A2697-20R..........................................................................................F23 A7537N4.............................................................................................F12
2723C...............................................................................................F15 A7537N4F ..........................................................................................F12
A2797-20R..........................................................................................F20 A7537P4 ............................................................................................F12
A2797-20R..........................................................................................F23 A7537P4F ..........................................................................................F12
2884D...............................................................................................F16 A7539R6 ............................................................................................F12
3146..................................................................................................F25 A7539R6F...........................................................................................F12
A3146..................................................................................................F25 A7539T6..............................................................................................F12
3146S................................................................................................F25 A7539T6F ..........................................................................................F12
3170..................................................................................................F24 A7539V6 ............................................................................................F12
3174C...............................................................................................F23 A7539V6F ..........................................................................................F12
3176..................................................................................................F25 7572-400...........................................................................................F27
A3176..................................................................................................F25 7572C-14A........................................................................................F19
3180C...............................................................................................F24 7572C-15A........................................................................................F19
3183AC.............................................................................................F24 7573D...............................................................................................F24
A3184-8R............................................................................................F20 7573DC.............................................................................................F24
A3186..................................................................................................F25 7574.................................................................................................. F11
A3194-8R............................................................................................F20 7574L................................................................................................ F11
3194C...............................................................................................F23 7579..................................................................................................F20
A3196..................................................................................................F25 7579P................................................................................................F20

F 3197C...............................................................................................F22 7579S................................................................................................F22
3199W...............................................................................................F16 7590U...............................................................................................F18
3272E................................................................................................ F11 7590U-10..........................................................................................F19
3272F................................................................................................ F11 7590U-20..........................................................................................F18
A3272G............................................................................................... F11 7591U...............................................................................................F18
3272G............................................................................................... F11 7647DC.............................................................................................F21
A3276BC.............................................................................................F25 7647H...............................................................................................F21
3282A................................................................................................ F11 7647HF.............................................................................................F21
3282B................................................................................................ F11 7647SA.............................................................................................F21
A3282C............................................................................................... F11 7647SC.............................................................................................F21
3282C............................................................................................... F11 A8013D...............................................................................................F15
A3292A................................................................................................ F11 A8013DA.............................................................................................F15
3292A................................................................................................ F11 A8013DB.............................................................................................F15
A3292B................................................................................................ F11 A8523..................................................................................................F12
3292B................................................................................................ F11 A8525..................................................................................................F12

F28
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section G
G G

Internal Valves and Accessories

G1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY


Except as expressly set forth above, and subject to the limitation of
LIMITED 10 YEAR WARRANTY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
Engineered Controls International, Inc. (“ECII”) warrants to the original WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
purchasers the products and repair kits manufactured by it to be free PARTICULAR PURPOSE, with respect to its products and parts,
from defects in materials and workmanship under normal use and whether used alone or in combination with others. ECII disclaims all
service for a period of 10 years from the date of manufacture. If within warranties not stated herein.
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the LIMITATION OF LIABILITY
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. NOTICE TO USERS OF PRODUCTS

This warranty does not extend to any product or part that is not The Limited Warranty stated above is a factory warranty to the first
installed and used continuously after installation in accordance with purchasers of ECII products. Since most users have purchased
ECII’s printed instructions, all applicable state and local regulations, these products from ECII distributors, the user must within thirty (30)
and all applicable national standards, such as those promulgated by days after the user’s discovery of what user believes is a defect,
NFPA, DOT and ANSI. This warranty does not extend to any product notify in writing and return the product to the distributor from whom
or part that has been damaged by accident, misuse, abuse, failure to he purchased the product/part. The distributor may or may not at
maintain, or neglect, nor does it extend to any product or part which the distributor’s option choose to submit the product/parts to ECII,
has been modified, altered, disassembled, or repaired in the field. pursuant to this Limited Warranty. Failure by buyer to give such
This warranty does not cover any cosmetic issues, such as scratches, written notice within thirty (30) days shall be deemed an absolute and
dents, marring, fading of colors or discoloration. unconditional waiver of buyer’s claim for such defects. Acceptance
of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

G Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
without notice.

G2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
G
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Cross Reference by Part Number............................................... G23
Flomatic® Service Guide............................................................ G19
Flomatic® Valves......................................................................... G17
General Information-Flomatic®................................................... G16
General Information-Manual Valves.............................................. G6
Manual Valves—1¼” Threaded..................................................... G8
Manual Valves—3” Threaded...................................................... G14
Manual Valves—2” Threaded...................................................... G15
Manual Valves—3” Flanged........................................................ G10
Manual Valves—4” Flanged.........................................................G11
Pump System Troubleshooting................................................... G23
Remote Cable Controls............................................................... G13
Remote Thermal Release........................................................... G13
Safety Warning.............................................................................. G4
G3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Warnings
Purpose
In its continuing quest for safety, Engineered Controls International, Inc. publishes a series of bulletins
explaining the hazards associated with the use, misuse, and aging of LP-Gas valves and regulators. It is hoped
that these factual bulletins will make clear to LP-Gas dealer managers and service personnel, that the utmost
care and attention must be used in the installation, inspection, and maintenance of these products, or problems
could occur which would result in injuries and property damage.

The National Fire Protection Association Pamphlet #58, “Storage and Handling of Liquified Petroleum Gases’’
states in section 1-6 that “In the interest of safety, all persons employed in handling LP-Gases shall be trained
in proper handling and operating procedures’’. These “ECII® Safety Warnings’’ may be useful in training new
employees and reminding older employees of hazards that can occur.

It is recommended that all employees be furnished with a copy of NPGA Safety Pamphlet 306-88 “LPGas
Regulator and Valve Inspection and Maintenance, 111-81 Limitations of Excess Flow Check Valves for LP-Gas,
and 113-78 Safety Considerations in Bobtail Deliveries.’’

Nature of Warnings
It is recognized that warnings should be as brief as possible, but the
factors involved in internal valve and excess flow valve failures to
perform are not simple. They need to be fully understood. If there is
a simple

Make sure that the internal valve’s excess flow feature really
closes when the flow exceeds rated closing flow, and that the
valve will shut-off.

This bulletin is not intended to be an exhaustive treatment of internal


valves, and certainly does not cover all safety practices that should
be followed in installation, operation and maintenance of LP-Gas
systems, which include internal valves.

Internal valves must be closed on Cargo Vehicles when traveling


G on public roads and highways. The valve should only be open
when pumping. Per MC 330 or 331, internal valves must also be
equipped with remote closure system, when used on transports
or bobtails.

There are two types of internal valves being used on storage


tanks, transports and bobtails — spring loaded internal valves and
differential pressure internal valves. They both provide positive shut-
off when product is not being withdrawn and may include excess flow
The exact procedure used may vary with the installation, advisability
protection for the system during transfer operations.
of gas discharge and availability of equipment.
Spring Loaded Internal Valves
In general, most testing makes use of the fact that the excess flow
valves are “surge sensitive’’ and will close quicker under a sudden flow
Spring loaded internal valves are manually opened by levers, by
surge than under steady flow. A sufficient surge can often be created
means of fuse linked cable mechanisms or pneumatic or hydraulic
by using a quick open/close valve to control sudden, momentary flow
actuators. They incorporate an excess flow feature that will close the
into a tank or piping section containing very low pressure. An audible
valve when the flow through the valve exceeds its rate of flow. These
click from the excess flow valve (and corresponding stoppage of flow)
valves should never be locked open by means of wires, chains, pegs
indicates its closure.
or other devices.

Testing A test involving venting gas to the atmosphere is hazardous and


may be impractical, or illegal.
Testing should be completed on a periodic basis.
Any test of any excess flow valve will not prove that the valve will
1. To check operation of a spring loaded valve, activate the remote
close in an emergency situation, due to reasons cited before. This
control to close the valve while unit is pumping. If the meter indicator
test will only check the valves condition, and the flow rate sizing for
flow continues, the valve should be repaired immediately.
those test conditions.
2. Testing excess flow feature.
3. Tight Shut-Off — A test should be made to insure the internal valve
The National Propane Gas Association Safety Bulletin #113-78
will give a gas tight seal when the valve is in the closed position. This
states: “In order to test an excess flow valve in a piping system, the
will require removal of all product downstream from the internal valve,
flow through the valve must be made to exceed the valve’s closing
to insure the valve will give 100% seal when in the closed position.
rating.’’
If the internal valve does not give 100% seal the valve should be
This testing should only be attempted by trained personnel familiar repaired immediately.
with the process. If no one at the facility has experience in proper
testing, outside expert help should be obtained.

G4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pressure Differential Internal Valves (Flomatics)
Pressure differential valves (Flomatics) open by pump pressure and
close when the pump stops.
These valves must never be locked open by means of wires, chains,
pegs or other devices.

Testing

Testing should be completed on a periodic basis.

1. To check operation of a differential pressure internal valve activate


the remote control shut-off valve while the unit is pumping. If the
meter indicates that flow continues the valve should be repaired
immediately.

2. Since the differential pressure internal valve requires at least 18


psi to open and 8 psi over container pressure to keep open, a test
may be performed to check for closure. With the PTO disengaged,
connect delivery hose to a container with very low pressure. Then
with hose end valve open, engage PTO. The internal valve should
remain closed, no flow should be detected through the meter. If
flow continues through the meter the valve should be repaired
immediately.

3. Tight Shut-Off — A test should be made to insure the internal valve


will give a gas tight seal when the valve is in the closed position.
First insure the pump prime valve is closed by turning clockwise until
it seats. Then with the valve closed (PTO disengaged) the product
downstream from the internal valve will have to be safely removed.
If the internal valve does not give 100% seal, the valve should be
repaired immediately.

General Warning
All ECII® Products are mechanical devices that will eventually
become inoperative due to wear, contaminants, corrosion and aging
of components made of materials such as metal and rubber. G
The environment and conditions of use will determine the safe service
life of these products. Periodic testing at least once a year when tank
pressures are low and maintenance, as required, are essential.

Because ECII® products have a long and proven record of quality


and service, LP-Gas dealers may forget the hazards that can occur
because an excess flow valve is used beyond its safe service life.
Life of an excess flow valve is determined by the environment in
which it “lives’’. The LPGas dealer knows better than anyone what
this environment is.

NOTE: There is a developing trend in state legislation and in proposed


national legislation to make the owners of products responsible for
replacing products before they reach the end of their safe useful life.
LP-Gas dealers should be aware of legislation which could effect
them.

G5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Manual Internal Valves
A3200 Series

General Information
These valves must remain in the closed position except during
product transfer. A line break downstream of the pump may fail to
Manual Internal Valves are designed for a variety of uses in LP-Gas
actuate the excess flow valve as the pump may limit flow. If break
and anhydrous ammonia service. In addition, accessories allow most
occurs in the system, or the excess flow closes, immediately shut
of them to be actuated manually, by cable or with air.
down the system.
Installation, usage and maintenance of this product must be
Inspection and maintenance on a periodic basis is essential.
in compliance with all Engineered Controls International, Inc.
Installation and maintenance must be performed only by qualified
instructions, as well as requirements and provisions of NFPA # 58,
personnel.
DOT, ANSI, and all applicable federal, state, provincial, and local
Be sure all instructions are read and understood before installation
standards, codes, regulations and laws.
and operation of these valves.

How The Valves Work 5. Always keep valve closed except during product transfer.
Refer to the drawings. View “A’’ shows the valve held closed without 6. Completely open all valves during pumping. Partially closed or
leakage by tank pressure and the valve’s closing spring. Actuation throttle type valves may prevent excess flow valve from closing when
of the operating handle alone does not open the valve, it only allows required, even in a properly designed piping system.
pressure to equalize between the inlet and outlet of the valve by rapid
bleeding of the product downstream. This equalized pressure then 7. All personnel must be aware of remote closure locations and their
allows the valve to open via the internal spring. operation in case of emergency. They must also be aware of the
equalizing opening through which bleeding can occur after the excess
The valve opens by moving the handle to mid-point, see view “B’’. flow valve closes. If this bleed is not stopped by closing a downstream
This position allows the actuator to put the equalizing portion of valve, a hazard may occur.
the valve stem in the pilot opening, allowing more product to bleed
downstream than if the handle was fully open. 8. Never, under any circumstances, permanently wire open the
operating handle of the internal valve.
In a few seconds, the tank and downstream pressure will be nearly
equal. The excess flow spring will push the main poppet to the open
position, see view “C’’, the handle should then be moved to the fully
Cable Control System
open position.
The cable control system employed must meet the requirements
and be in accordance with the provisions of NFPA #58, DOT,
If at first, the handle is quickly moved to the fully opened position, the
pilot valve allows a small amount of bleed downstream, but much less ANSI, and all applicable federal, state, provincial and local
than during rapid bleed (view “B’’). This results in a longer pressure codes.
G equalizing time before the main valve can open.
Troubleshooting
NOTE: The main poppet will not open until outlet pressure
approximates tank pressure! 1. Internal Valve Will Not Open. Causes may be excess leakage
downstream, pump engaged too quickly, excessive wear of valve, or
Once the main poppet is open, flow greater than the excess flow ice freezing of poppet.
rating, or a sufficient surge in flow, forces the main poppet closed When there is excessive volume downstream, a greater amount of
against the excess flow spring, as seen in view “D’’. The pilot valve in time is required to equalize tank and downstream pressure.
this position is open and allows a small amount of bleed downstream, To determine if the pilot seat is opening, install a pressure gauge
but much less than during rapid bleed (view “B’’). downstream of valve outlet, open any hand valves between valve and
pressure gauge, and open valve. Pilot seat is not opening if pressure
When the operating handle is moved to the closed position, the valve does not build up to tank pressure. Perform this test with pump off. A
closes and a leak-tight seal is re-established as seen in view “A”. broken internal part may cause pilot seat not to open.
If operating handle rotates past the full open position, there is internal
NOTE: To provide excess flow protection, the flow rating of the pump, malfunctioning, and the valve must be disassembled and repaired.
piping, valves, fittings, and hose on the inlet and outlet sides of the
2. Premature Valve Closure.
valve must be greater than the flow rating of the valve. Any restrictions
that reduce the flow to less than the excess flow valve rating will result First, check to see that operating lever is properly connected and fully
in the excess flow valve not operating when required. opens valve. Premature closure may also be a result of engaging
pump too quickly, sudden line surges, an underrated excess flow
Valve Operation and Precautions spring or an obstructed inlet port.
3. Valve Will Not Close.
1. Valve must be opened before starting pump, and before opening Usually a result of faulty or sticking actuator. First, check the actuator
valve on pump outlet. to see that it works freely by disconnecting it from valve handle and
cycling it several times. Also, operate valve handle manually. If it
2. Leave pumping system “wet’’ to avoid drying of seals and to reduce sticks in the open position, replace the packing and bushings. This
time involved in opening valve. Drain piping only when required by should free the operating mechanism providing the valve has no
codes or safe operating practices. internal damage.
3. When piping is dry or at lower pressure than the tank, open valve
4. Low Flow Capacity
half-way for a few seconds to allow line pressure to equalize before
Downstream piping may be too small and/or long, screen or strainer
fully opening the valve handle. The main poppet may not open
immediately if the handle is placed in the open position too quickly. may be plugged, possible restriction downstream, or a bypass valve
stuck in the open position are causes of low flow. Also, the bypass
4. Flow surges may close the built-in excess flow valve and should valve may be set too low and prematurely opening. Check for high
be avoided. If the valve slams shut, immediately stop the pump, close differential pressure across the bypass valve. If bypass valve is open,
the nearest downstream valve, and move handle to midpoint position the differential across the valve should not exceed 5 to 6 psig.
to equalize pressure until valve reopens with a click, then restart
pump and open downstream valve slowly.

G6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Maintenance
Potential problems may be eliminated with preventive internal valve 3. Inspect, clean and oil all operating controls. Check controls to see
maintenance. Perform the following steps once a month: that they open fully, but do not overtravel the valve operating lever.
See that they work freely to close the valve. Worn parts should be
1. Check to see that the operating lever moves freely and smoothly. replaced.
There should be no leakage around the lower stem or seal housing.
Leakage requires replacement of the seal housing packing. A sticking 4. Remove valve if the tank is to be steam cleaned. Heat may
lever indicates trapped foreign material or mechanism wear. damage the valve’s seals.

2. Check both seat discs for tight closure. Close valve and exhaust 5. Valve is not designed for water service. After tank is hydrostatically
downstream pressure. Be sure piping is warmed to an ambient tested, immediately remove all water and allow tank to thoroughly dry
temperature. Close the first downstream valve and note pressure out before installing valve.
buildup between the closed valves with a pressure gauge. If leakage
occurs, replace both seat discs.

A3209R Series, 11⁄4” Straight


A3212R Series, 2” Straight
A3212RT Series 2” Tee Body
A3213A Series, 3” Straight
A3213T Series 3” Tee Body

A3217F Series, 3” Flanged


A3217DF Series,
3” Double Flanged

A3219F Series, 4” Flanged

G7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
1¼” Threaded Internal Valve for Small Capacity Pumping Systems
and Bobtail Vapor Equalization A3209D & A3209DT Series
Application We have redesigned our A3209R Series internal valves; the new part
number will be A3209D Series the list price will not change.
Designed primarily for use with LP-Gas and anhydrous ammonia as a
main valve on small capacity pumping systems, NH3 nurse tanks and Your orders for the A3209R050 and A3209R080 will be changed to
in-line installations. It may also be installed in the vapor equalizing the new part number for orders scheduled as follows:
opening on bobtail delivery trucks. Installation is quick and easy, and
it fits in both full and half couplings, as well as, in-line applications. A3209R050 to A3209D050: your orders scheduled for delivery after
The valve may be actuated manually by hand or cable.
UL
®
June 2007.

A3209R080 to A3209D080: your orders scheduled for delivery after


Features
February 2007.
• Valve is compact, with one piece body construction.
We have developed a new Tee style A3209DT050 and A3209DT080 that
• Spring loaded V-packing with heavy duty wiper ring on operating will replace the A3210A065. The List price for this valve is: $ 417.30
shaft for dependable leak-free construction.

• Nylon bearing supported operating shaft provides smooth, easy


operation.

• Simple operating lever allows for easy connection of cable controls.

• Built in excess flow valve

• Return spring forces the valve to the closed position when the
lever is released.

• All critical operating components are located in the valve body


and inside the container coupling for maximum protection against
damage.

• Midway stem position allows for quick pressure equalization. A3209DT

• Equipped with 212° F, UL listed fuse link for thermal protection.


G 2¾”
Materials
Body.................................................................................. Ductile Iron
Operating Lever................................... Cadmium Plated Carbon Steel
Stem............................................................................ Stainless Steel
Springs........................................................................ Stainless Steel Top View
Seat Disc................................................... Resilient Synthetic Rubber
Shaft Bearing.............................................................................. Nylon A3209D

Seat disc fully retained and


field replaceable

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Cam attached with Allen


head fastener which is
accessed from the ¼” pipe
plug on side of the body

Ordering Information
Inlet Outlet Closing Flow LP-Gas Vapor Capacity** (SCFH/Propane) Accessories
Part
Connection Connection
Number LP-Gas NH3 25 PSIG 100 PSIG Thermal Latch Pneumatic Actuators
M. NPT F. NPT
A3209D050 1¼” 1¼” 50 45 13,300 22,900
A3209D080 1¼” 1¼” 80 72 15,700 26,700 A3209PA
A3209TL
A3209DT050 1¼” 1¼” 50 45 13,300 22,900 A3209PAF

A3209DT080 1¼” 1¼” 80 72 15,700 26,700

G8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
3” Flanged Internal Valve for Bobtail Delivery Trucks, Transports,
and Large Stationary Storage Tanks A3217 Series
Application
Designed primarily for LP-Gas and anhydrous ammonia filling and/ UL
®

or withdrawal on MC331 bobtail delivery trucks, transports and


stationary storage tanks with flanged pumps or piping. Installation is
quick and easy, and the valve may be operated manually by cable or
pneumatically.
Lever available on right or left side to allow for installation without the
use of an extra pulley.

Features
Provides More Efficient Operation
• Flow passages designed to allow substantially higher without
cavitation or loss of efficiency--saving time and money.

• Simple operating lever facilitates easy adaptation of all cable


controls.
A3217FPA on A3217FR
A3217 FR Series
• Lever available on right or left side to allow for installation without Single Flange Valve
the use of an extra pulley.

• Nylon bearing supported operating shaft provides smooth, easy


operation.

Less Frequent-Easier Maintenance


• Easily replaceable nickel chrome plated seat insert eliminates
need for expensive remachining of valve body when overhauled.

• Stainless steel screws resist rusting and are easily removed


during valve disassembly.

• Strainer sits on the top flange of the valve’s seat insert, making
removal of the valve easier. It completely covers the top of the G
valve to help keep out sediment and foreign material.

• Heavy duty rod wiper helps minimize dirt and foreign material from
A3217FR & FL Series
entering operating shaft and hampering operation.
Single Flange
Durable Construction A3217DFR & DFL Series
• Cadmium plating helps resist corrosion during storage and use. Double Flange

• Main disc retaining screws are installed from the top down to help
minimize the chance of loose screws entering and damaging the
pump.
PRODU

10
O
• All ferrous materials with a temperature range of -40° F. to +130°
G

CT

F. and a pressure rating of 400 psi w.o.g.


RE

• Sturdy retaining ring secures operating cam to provide for more


10

durable, slack-free operation.


NT

E
Y

AR A
• Built-in excess flow valve. WA R R

• Specify RegO® Internal Valves on your next new tank body or


whenyour tank is rebuilt.

Ordering Information
Part Closing Flow
Number GPM Accessories
Operating
Single Flange Double Flange Lever Inlet Outlet Pneumatic
Body Body Position Connection Connection LP-Gas NH3 Actuator
A3217FR160 A3217DFR160 Right Side A3217FPA
160 145
A3217FL160 A3217DFL160 Left Side A3217FLPA
A3217FR210 A3217DFR210 Right Side 3” 300# A3217FPA
3” 300# 210 190
A3217FL210 A3217DFL210 Left Side ANSI RF A3217FLPA
ANSI RF
A3217FR260 A3217DFR260 Right Side Modified A3217FPA
Flange 260 236
A3217FL260 A3217DFL260 Left Side Flange** A3217FLPA
A3217FR410 A3217DFR410 Right Side A3217FPA
410 372
A3217FL410 A3217DFL410 Left Side A3217FLPA
* Valve supplied with 16 nuts and 8 studs for mounting. **Modified bore = 4 ⁄8” diameter with 5 ⁄4” diameter raised face.
5 3

G9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
3” Flanged Internal Valves for Bobtail Delivery Trucks,
Transports, and Large Stationary Storage Tanks
A3217FPA and A3217FLPA Pneumatic Actuators
These Pneumatic Actuators are designed specifically for use with the
A3217 Series 3” Internal Valves. The diaphragm design provides a
UL
®

convenient means of opening and closing the valve from a remote


location, using either air or nitrogen.

Features
• Diaphragm type–no seals to leak.

• Easily installed on internal valve “in-line.’’

• Utilizes standard air brake chamber with proven performance over


many years of heavy-duty truck/trailer applications.

• Compatible with existing air interlock systems.

• Operates with pressures of 50-150 psig.

• Thermal Fuse installed complies with DOT thermal protection


requirements.

Materials
Body and Valve Cage.......................... Cadmium Plated Ductile Iron
Seat....................................................... Nickel Chrome Plated Steel
Strainer...................................................................... Stainless Steel
Shaft.......................................................................... Stainless Steel
Pilot Valve Stem........................................................ Stainless Steel
Springs...................................................................... Stainless Steel
Actuator Cam............................................................ Stainless Steel
Lever................................................ Cadmium Plated Carbon Steel
G Seat Disc................................................. Resilient Synthetic Rubber

G10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
4” Flanged Internal Valve for Transports and Large Stationary
Storage Tanks A3219 Series

Application
Designed primarily for LP-Gas and anhydrous ammonia service on UL ®

MC331 transport pressure vessels and large stationary storage tanks.


Installation is quick and easy, and it fits in most existing tank flanges.
The valve may be actuated manually or pneumatically.
Use of the A3219RT Remote Thermal Release with this valve is
suggested to provide a remote means of mechanical closure along
with thermal protection, as required by DOT.

Features
Provides More Efficient Operation
• Flow passages designed to allow higher pumping rates without
cavitation or loss of efficiency–-saves time and money.

• One piece, stainless steel pilot valve provides more accurate


alignment for dependable operation.

• Remote release lever allows cables to run directly to opposite


ends of vessel without pulleys or tubing.
A3219FPA
Protects Your Pump
• Main disc retaining screws are installed from the top down to help
minimize loose screws from entering and damaging the pump.

• Back-up cotter pin is designed to minimize the chance of a


loosened actuator nut and washer from entering and damaging
the pump.

Less Frequent-Easier Maintenance


• Easily replaceable chrome plated seat insert eliminates need for
expensive remachining of valve body when overhauled.
G
• Stainless steel screws resist rusting and are easily removed
during valve disassembly.

• Strainer completely covers the top of the valve to help keep out
sediment and foreign material.

• Stainer seats at the top flange of the valve’s seat insert, making
removal of the valve easier.

Durable Construction
• Cadmium plating helps resist corrosion during storage and use.

• Taper pin lock secures the operating shaft to provide for more
precise,trouble-free actuation.
Materials
• Built-in excess flow valve and thermal protection.
PLOT GENERATED 8/08/2002 AT 15:15

Body and Valve Cage.......................... Cadmium Plated Ductile Iron


• Specify RegO® Internal Valves on your next new tank body or Handle................................................. Cadmium Plated Ductile Iron
rebuild. Seat....................................................... Nickel Chrome Plated Steel
Strainer...................................................................... Stainless Steel
PRODU Stem.......................................................................... Stainless Steel

10
O
Pilot Valve Plug.......................................................... Stainless Steel
G

CT
RE

Springs...................................................................... Stainless Steel


S

Roller Actuator.................................. Cadmium Plated Carbon Steel


10

Y
NT

E
Y

A
AR
WA R R Lever Assembly................................ Cadmium Plated Carbon Steel
Seat Disc................................................. Resilient Synthetic Rubber

Ordering Information
Closing Flow GPM Accessories
Part Number* Inlet Connection Outlet Connection Pneumatic Remote Thermal
LP-Gas NH3
Actuator Release
A3219FA400L 4” 300# ANSI RF 4” 300# ANSI RF 400 360
A3219FPA A3219RT (2)
A3219FA600L Modified Flange** Flange 600 540
* Valve supplied with 16 nuts and 8 studs for moutning.
** Modified bore = 5 7/8” diameter with 7” diameter raised face.

G11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
4” Flanged Internal Valves for Transports and Large Stationary
Storage Tanks

Application
UL
A3219FPA Pneumatic Actuator
®

The A3219FPA Pneumatic Actuator is designed especially for use


with the A3219FA Series Flanged Internal Valves. The diaphragm
type A3219FPA provides a convenient means of opening and closing
the valve from a remote location, using either air or nitrogen, on LP-
Gas and NH3 transport trailers and stationary tanks.

Features
• Diaphragm type–no seals to leak.

• Easily installed on internal valve “in-line,’’

• Utilizes standard brake actuator with time proven performance in


heavy-duty truck/trailer applications.

• Compatible with existing air interlock systems.

• Operate with pressures of 50-150 psig.

• Thermal fuse installed in actuator complies with DOT thermal


protection requirements.

G12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Remote Thermal Release for DOT MC331 Pressure Vessel
A3219RT
Application
Designed especially for use with Internal Valves installed in DOT
UL
®

MC331 pressure vessels. The A3219RT provides a remote means


of mechanical closure along with thermal protection, as required by
DOT MC331. A3219RT
The A3219RT is connected by cable to the internal valve(s) on the
vessel. In the event of extreme heat (over 212° F.), the fuse link will Features
melt, causing the spring to contract and pull the cable. When properly
installed the cable will trip the internal valve release lever(s) allowing • Meets DOT MC331 requirements.
the connected handle(s) to move to the closed position.
• Easily installed, rugged formed steel bracket has open bottom to
Materials minimize dirt and water build-up.

Body...................................................................... Galvanized Steel • Heavy, shouldered pins lock into position.


Springs...................................................................... Stainless Steel
• Stainless steel spring provides dependable performance with 100
Ordering Information lb. load.
Spring Load Minimum
Number
• Heavy-duty chain adapts easily to standard cable and fittings.
Part For Use Release Fully After 4” Required
Number With Temperature Extended Travel By MC331 • Fuse link has 212° F. release temperature.
Internal
A3219RT 212° F. ≈100 lbs. ≈50 lbs. 2 • Adapts easily to standard cables and fittings.
Valves

PRODU

10
O

CT
RE

S
10

Y
NT
E

Y
AR A
WA R R

G
Remote Cable Controls for Internal Valves 3200C and 3200L
Application
UL
The 3200C Remote Cable Kit is designed especially for use with the ®

3200L Remote Operating Lever to operate internal valves from a


remote location.
The internal valve is opened by pulling back the remote operation
lever and closed by returning the lever to its original position. A
remote release is provided to close the internal valve from a different
remote location.
Features
• Metal construction provide durability in heavy duty applications.

• Toggle action of operating lever allows for quick closure without


extra springs and latches.

• The unique clamping nut and cable clamps provide easy


installation.

• Fuse connections allow internal valves to close if connections are


exposed to fire.
PRODU

10
O
G

CT

• Versatile design permits installation on bobtails and stationary


RE

tanks at bulk plants.


10

Y
NT

E
Y

AR A
• Provides necessary remote closure system for bobtails required WA R R
by DOT regulation on MC330/MC331 tanks and NFPA #58.
Ordering Information
Part Materials
Number Description Contents
100 Foot Cable, 6 Cable Clamps, Quick Body...................................................................... Galvanized Steel
3200C Remote Cable Kit
Link, Sign, Fuse Link, Steel Nut and Bolt
Springs...................................................................... Stainless Steel
3200L Operating Lever Lever Assembly
G13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Threaded Internal Valves For Bobtail Delivery Trucks, Transports
and Stationary Storage Tanks A3213R Series
Application Seat disc fully retained and field replaceable.
Excess flow spring is independent from
Designed primarily for use with LP-Gas and anhydrous ammonia
return spring operation
for liquid withdrawal; vapor transfer or vapor equalization of bobtail
delivery trucks, transports, stationary storage tanks, and in-line
installations. The valve may be operated manually by cable or
pneumatically.

Features
• May be installed in full and half couplings.

• Nylon bearing supported operating shaft provides smooth, easy


operation.

• Simple operating lever facilitates easy adaptation of all cable


controls.

• Midway stem position allows for quicker pressure equalization.

• All critical operating components are located in the valve body inside
the container coupling for maximum protection against physical
damage.
A3213R
• Built in excess flow valve.
Cam attached with Allen head fastener which is
• Return spring returns the valve to the closed position when the accessed from the ¼” pipe plug on side of the body
handle is released.

• Specify RegO® Internal Valves on your next new tank body or when
your tank is rebuilt.

G • A3213PA pneumatic actuator provides a convenient means of


opening and closing the valve from a remote location, using either
air or nitrogen for A3213R service valves.
Materials
Body.................................................................................. Ductile Iron
Operating Lever............................................... Cadmium Plated Steel UL®

Stem............................................................................ Stainless Steel


Springs........................................................................ Stainless Steel
Seat Disc................................................... Resilient Synthetic Rubber
Shaft Bearing.............................................................................. Nylon

A3213RT
PRODU

10
O
Cam attached with Allen head fastener
G

CT
RE

that is accessed from the 3” F-NPT outlet


10

connection on the side of the body


NT

E
Y

AR A
WA R R

Ordering Information
Closing Closing
LP-Gas Vapor
Flow Half Flow Full
Capacity (SCFH/ Accessories
Inlet Outlet Coupling Coupling
Part Propane)
Connection Connections (GPM) (GPM) A B C D E F
Number
M-NPT F-NPT 25 100
Pneumatic Thermal
LPG NH3 LPG NH3 PSIG PSIG
Actuator Latch
Inlet Inlet
A3213R150 150 135 125 113 - -
A3213R200 200 180 160 144 44,100 75,100
11⁄2” 57⁄8” 41⁄4” - - 71⁄8”
A3213R300 300 270 250 225 57,900 90,500
A3213R400 400 360 325 293 71,400 121,300
3” 3” A3213PA A3213TL
A3213RT150 150 135 125 113 - -
A3213RT200 200 180 160 144 44,100 75,100
11⁄2” 715⁄16” 41⁄4” 37⁄8” 41⁄2” 31⁄2”
A3213RT300 300 270 250 225 57,900 90,500
A3213RT400 400 360 325 293 71,400 121,300

G14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Threaded Internal Valves For Bobtail Delivery Trucks, Transports
and Stationary Storage Tanks A3212 Series
Application
Designed primarily for use with LP-Gas and anhydrous ammonia PRODU

10
O
for liquid withdrawal; vapor transfer or vapor equalization of bobtail

CT
RE

S
delivery trucks, transports, stationary storage tanks, and in-line

10

Y
installations. The valve may be operated manually by cable or

NT
E

Y
AR A
pneumatically. WA R R

Features
• May be installed in full and half couplings.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Simple operating lever facilitates easy adaptation of all cable
controls. UL
• Midway stem position allows for quicker pressure equalization.
®

• All critical operating components are located in the valve body


inside the container coupling for maximum protection against
physical damage. A3212R Series
• Built in excess flow valve.
• Return spring returns the valve to the closed position when the
handle is released.
• Specify RegO® Internal Valves on your next new tank body or
when your tank is rebuilt.
• A3213PA pneumatic actuator provides a convenient means of
opening and closing the valve from a remote location, using either
air or nitrogen for both the A3212R & A3213A service valves.

Materials
A3212R Series
Body............................................................................... Ductile Iron
Operating Lever............................................. Cadmium Plated Steel
Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel
G
Seat Disc................................................ Resilient Synthetic Rubber
Shaft Bearing........................................................................... Nylon

A3212RT Series

Ordering Information
Closing Flow (GPM) Closing Flow (GPM)
Inlet Outlet Accessories
Part Half Coupling Full Coupling
Connection Connection
Number
M. NPT F. NPT LP-Gas NH3 LP-Gas NH3 Thermal Latch Pneumatic Actuator

A3212R105
105 95 65 59
A3212RT105
A3212R175
2” 2” 175 158 100 90 A3213TL A3213PA
A3212RT175
A3212R250
250 225 130 117
A3212RT250

G15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Flomatic® Internal Valve Operation

General Information
RegO® piston type Flomatic® Internal Valves are normally closed
and use pressure differential to provide completely automatic service.
Mounted directly between the tank body and pump, the Flomatic®
uses the pressure differential developed by the pump to open the
valve and it closes automatically when the differential no longer
exists.
This means the RegO® Flomatic® opens when the pump is on and
closes when the pump is shut off – fully automatic.

3. Pump On – Valve Open


The force below the pilot stem forces the piston up to open the valve;
rotating the INDICATOR SLOT to its vertical (valve open) position.
Pump differential pressure in area D holds the PILOT STEM and
PISTON open. Approximately 20 psig pump differential pressure is
required to open the valve; approximately 8 psig differential pressure
1. Normally Closed will hold the valve open.
When the valve is closed, liquid flows into the INLET PORTS, through
a channel in the PISTON, and into area A. It also flows down through
the PRIMING CHANNEL in the valve body, into area B beneath the
valve seat, and into area C to prime the PUMP.

4. Pump Off – Valve Closes


With the pump shut off, the pressure in area D which holds the
2. Pump On – Valve Opening valve open, bleeds out through the #60 DRILL ORIFICE. This loss
When the pump is started, differential pressure transmits through the of pressure permits the SPRING to push the PILOT STEM down to
1⁄4” piping into chamber D. lifting the PILOT STEM. This opens the reseat at point E. Since pressures are equal above and below the
seat between the stem and piston at E. Pump suction then evacuates PISTON, with no sustaining pressure in area D, the SPRING forces
the tank pressure in area A, which becomes equal to the pump the valve closed. The INDICATOR SLOT rotates to the horizontal
suction pressure. (valve closed) position.

G16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports
and Large Stationary Storage Tanks A7883FK and A7884FK

Application
Designed primarily for LP-Gas and anhydrous ammonia liquid UL
®

withdrawal on MC331 bobtail delivery trucks, transports and large


stationary storage containers with flanged connections. The valve is
fully automatic, opening and closing as the pump is turned on or off.

Features
Fully Automatic
• Operates on pressure differential from the pump to open and
close.
• Automatically closes should downstream line rupture causing loss
of pump differential pressure required to keep the valve open.
• Problems of improperly sized excess flow valves slugging shut
during liquid transfer are eliminated.

Faster Unloading
• Straight through flow design provides minimum pressure drop and
large flow capacity to the pump, resulting in higher flow rates and
greater pump efficiency.
• Unloading is quicker and turn-around faster to provide more
A7883FK
profitable operation.

Greater Protection
• Fully automatic operation virtually eliminates operator errors such
as forgetting to close the valve after product transfer.
• Fully internal design reduces possibility of spillage that may result
from a collision.
• Built-in visual indicator lets the operator know whether the valve
seat is in the open or closed position.
• Never a cable problem. These valves must NEVER be held open
by wire or any other means as the valve will not close as expected
when the pump is shut-off.
G
Less Maintenance
• Easily replaceable, high efficiency external filter removes
contaminant’s as small as 20 microns. Filter virtually eliminates
orifice clogging, excessive internal filter maintenance and service
downtime.
• No need to check or replace air lines, cables or cable
connections.

Economical
• Completely equipped with mounting bolts, flange gaskets, quick
acting valve and filter - all in one purchase price.
• No need to purchase additional mounting equipment or actuating
accessories.
• Specify RegO® Internal Valves on your next new tank body or
when your tank is rebuilt.

Materials
Body................................................................................ Cast Steel PRODU

10
Valve Stem............................................................... Stainless Steel O
G

CT

Operating Stem........................................................ Stainless Steel


RE

Piston............................................................................... Aluminum
Cylinder.................................................................... Stainless Steel
10

Y
NT

Screen...................................................................... Stainless Steel E


Y

AR A
Seats...................................................... Resilient Synthetic Rubber WA R R

Ordering Information
Accessories (included with Flomatic®)
Part Inlet Connection Outlet Connection Strainer Base Overall Height Height from Indicator
Number ANSI Flange ANSI Flange Width Width (Approx.) to Base Filter 3-Way Valve
A7883FK 3”-300#** 3”-300# 4¾” 8¼” 10⅞” 413⁄16”
A7884-201 A7853A
A7884FK 4”-300#*** 4”-300# 5¾” 10” 11¼” 415⁄16”
* Supplied with A7853A 3-way valve, A7884-201 filter, studs, nuts and gaskets.
** With 413⁄16” diameter bore.
*** With 513⁄16” diameter bore.

G17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
¼” Three-Way Quick-Acting Valve
A7853A

UL
®

Flomatic Valve A7853A ¼” Three-Way


Typical Installation Quick-Acting Valve

Tank Flange
Flomatic filter
Tank Gasket Flange
(To Pump Station
¼” Vent Line
¼“ High Tee

G Pressure
Hose

Pump
Control Cable
(with Fuse link
and return spring)
A7853PA
A7853A Three Way Valve

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Accessories
Overall Height from
(included with Flomatic®)
Inlet Connection ANSI Outlet Connection Strainer Base Height Indicator to
Part Number Flange ANSI Flange Width Width (Approx.) Base Filter 3-Way Valve
13
A7883FK 3”-300#** 3”-300# 4¾” 8¼” 10⅞” 4 16”
15 A7884-201 A7853A/A7853PA
A7884FK 4”-300#*** 4”-300# 5¾” 10” 11¼” 4 16”
* Supplied with A7853A 3-way valve, A7884-201 filter, studs, nuts and gaskets.
** With 413⁄16” diameter bore.
*** With 513⁄16” diameter bore.

G18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
On The Job Service Guide for the Flomatic® Valve
Introduction
Efficient, profitable transport and delivery truck operations depend on
keeping the equipment working safely and efficiently under changing
conditions. It is important to know how to eliminate expensive delays
by handling unloading problems as they arise.

The purpose of this technical guide is to provide basic information on


the Flomatic® valve, along with simple, appropriate steps to follow in
the event things go wrong.

The Flomatic® valve is mounted on the bottom of your transport or


delivery truck tank, with the pump mounted immediately downstream.
When the pump starts to push the liquid down the piping, the
Flomatic® Valve opens automatically, allowing you to unload the tank,
and closes when the pump stops pushing. It takes at least 20 pounds
per square inch of “push’’ at the pump to open the valve.

Your flanged Flomatic® valve has an indicating shaft on it that


shows whether it’s open or closed (Figure 1). If the indicating shaft is
horizontal, the valve is closed. If it’s vertical, the valve is open.

A threaded type, diaphragm-operated Flomatic® valve has an


indicating shaft on the bottom, covered by a clear plastic hood.
The indicating shaft projects down when the valve is closed and is
concealed when the valve is open (Figure 2).

Important Facts About Pressure


When handling propane or anhydrous ammonia, storage and
transport tank pressures vary from about 20 pounds per square inch
or less when it’s cold to 200 pounds per square inch or more in hot
weather (Figure 3). If you’re hauling butane, tank pressures will be 50
pounds per square inch or less.

The transport or delivery truck tank pressure may be higher than the
storage tank pressure when you are ready to unload (Figure 4). This
G
is because your rig may have been freshly loaded at the terminal or
bulk plant without a vapor equalizing line and hasn’t had time to get
back to normal. Also, the storage tank pressure tends to drop when a
lot of LPGas is being used.

Troubleshooting on the Job


O.K. So you follow your procedures, hook up your hoses, open the
required valves and start your pump. The indicating shaft on the
Flomatic® valve moves to the open position and the liquid goes in to
storage. Great! You’re happy and so is the boss, and so are we.

But, let’s say you do these things, start the pump and the liquid
doesn’t move. Now, how do you find out what is wrong?

G19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
On The Job Service Guide for the Flomatic® Valve
Step 1 6. Ice in the system may prevent proper operation, as will a
Immediately shut down the pump so you don’t cause possible collapsed or kinked sensing line or a clogged sensing line filter.
damage to the seals or valves. Next: If you found the trouble within STEP 1, just start the pump and
continue unloading, If not, proceed accordingly.
1. Check all manual valves in the system to make certain they
are open or closed as required for proper operation. a. New Models with T-handle: To adjust to the proper
position, push in the end of the valve stem and tighten the
2. Check the liquid level in the transport or delivery tank. If the needle valve clockwise until it seats. Then, turn
level is low, it may slow the transfer rate. counterclockwise 1½ turns.

3. Check to assure that the pump rotates normally when power b. Old Models with Plug: To adjust to the proper position,
is applied. If not, inspect and repair as needed the power takeoff, carefully remove the plug. A small amount of liquid
universal joints, drive shaft and clutch, etc. LP-Gas may be discharged when plug is loosened. Insert
a small screwdriver and tighten the needle valve
4. Make sure the lever is straight out on the ¼” operating valve clockwise until it seats. Then turn it counterclockwise
in the line between the pump discharge line and the Flomatic® 1 turn only. CAUTION: Do not open needle valve
valve (Figure 5). If is isn’t, the Flomatic® valve will remain closed. more than 1 turn as it might blow out!

5. Make certain the priming valve on the side of the Flomatic® c. Threaded Models with Internal Priming Channel. The
valve is open (Figure 6). internal priming channel normally self-actuates. To be sure
the system is primed, remove the plastic hood and push
the travel indicator up about 1⁄8” and hold for at least 15 seconds.

For Transport Trailer Trucks Only (Figure 7a)


1. Check the difference between the pressure
in your transport and the storage tank. If there’s
15 or 20 pounds per square inch more pressure
in the transport tank than in the storage tank,
chances are the Flomatic® valve won’t open.
This is because the pump can’t develop enough
“push’’.

If you have a good bypass valve on your rig


to send the extra liquid back into the tank, you
can merely close the liquid shut-off valve in the
discharge line and restart your pump (Figure 8a).
Now, the Flomatic® indicating shaft should move
to the open position (see Figures 1 and 2).

2. Slowly open the liquid shut-off valve in the


discharge line and the liquid will start to move out
of the transport. If the Flomatic® valve indicating
shaft starts to move toward the closed position
once you’ve opened this liquid shut-off valve
all the way, throttle the valve for a while until
the transport tank pressure drops to where the
Flomatic® valve indicating shaft will stay open.
Then, open the liquid shut-off valve all the way
until you finish unloading.
Figure 7a. Unloading Diagram of Transport Trailer Truck
The liquid flows out of the transport tank through the Flomatic® valve, into the pump and through the delivery hose to the storage tank. The vapor line
allows vapor to flow from storage back to the transport so that the storage tank pressure won’t build up too much and make the pump work harder
than necessary.

G20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
On The Job Service Guide for the Flomatic® Valve

3. If your pump system doesn’t have a


bypass valve, the liquid shut-off valve in
the discharge line should be left partially
open when you restart the pump. Just be
sure that the pump is pushing at least 20
pounds per square inch, so the Flomatic®
valve can open.

Don’t worry about how much it may slow


up your loading speed when you pinch
down the liquid shut-off valve to get the
Flomatic® valve open. Your pump is
running at constant RPM and will move
liquid at almost the same rate, even when
pushing harder. (It’s a lot like using engine Figure 8a. Unloading Diagram of Transport Trailer Truck
braking on a downhill grade, except, in this with Back-to-tank Bypass Valve You must have a separate back-
case, the pump keeps the liquid moving at to-tank bypass valve if the pump is to be run with the liquid shut-off
a constant flow rate.) valve closed.

For Delivery Trucks Only (Figure 7b)

1. Check the pump bypass piping. If


your truck is equipped with a manual
bypassvalve, close it and try the pump G
again. (Figure 8b). If the Flomatic® valve
indicating shaft moves to the open position,
the
problem is that the pump can’t develop 20
pounds per square inch or more to “push’’
open the Flomatic® valve with the bypass
valve open. You can prevent this in the
future by not opening the manual bypass
valve too wide. Figure 7b. Unloading Diagram of Delivery Truck
The liquid flows out of the truck tank, through the Flomatic® valve and into the pump, where
2. If the delivery truck is not equipped it is then pushed through the meter and delivery hose into the storage tank. The liquid
with a manual bypass valve, merely start normally enters the vapor space of the storage tank to minimize pressure buildup, so a
the pump. Slowly close the shut-off valve vapor equalizing line is usually not needed. The back-to-tank bypass valve opens to divert
between the back-to-tank bypass valve excess pump capacity back to the truck tank, preventing the pump from creating too much
and tank. If the Flomatic® valve indicating pressure.
shaft moves to the open position as you
close the valve, the back-to-tank bypass
valve may be stuck open, adjusted too low,
or the spring may be broken. CAUTION:
Don’t close the shut-off valve all the
way, because excessive pressures and
pump damage may occur.

3. If the Flomatic® valve indicating shaft


remains in the closed position, the problem
is either in the pump or the Flomatic®
valve.

G21
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
On The Job Service Guide for the Flomatic® Valve

USE EXTREME CARE AT ALL TIMES WHEN WORKING AROUND YOUR VEHICLE!
Watch out for drive shafts and moving parts. It is common knowledge that serious injury
can result if any part of one’s body or clothing is caught in moving machinery.

If you manually open the Flomatic® valve, you are responsible for safely unloading the
liquid and closing the valve when you’re through. If this procedure is being followed,
under no circumstances must the valve be left unattended. The valve must never be
permanently held in the open position.

If you are not able to cause the Flomatic® valve indicating shaft to
move to the open position after completing the preceding steps, a
complete detailed diagnosis will have to be made.

In the meantime, you can actuate the flanged Flomatic® valve by


using a special wrench and attempt to unload manually (Figure 9).

If you still can’t unload by following the preceding steps, it is


suggested that you unload by an alternate method, such as through
the valve normally used for liquid filling.

In any event, if you haven’t solved the problem and the unit still
doesn’t operate properly, immediately take it out of service, have a
complete analysis made and repair as needed.
G
Be sure to obtain and keep available for quick referral the
Manufacturers’ Operation and Service Manuals for the valves,
pump, meter and all operating equipment in the system.

G22
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pumping System Troubleshooting Guide
Introduction
Most LP-Gas and anhydrous ammonia systems use pumps to This would allow pressure gauges to be put in easily without
move liquid from one location to another. Unloading transport trailer removing the LP-Gas or anhydrous ammonia from the system
tanks into plant storage, loading delivery trucks, filling bulk tanks, at the time trouble occurs, saving a lot of time and unnecessary
engine fuel tanks, portable cylinders, etc. and pressurizing LP-Gas expense. Pressure gauges should be installed temporarily at the
vaporizers are only a few of many such applications. A well-designed time the system is first installed, and pressure readings recorded
and properly installed pumping system will perform well for some while the system is working properly. Then, in many cases,
time, but eventually problems occur requiring attention. merely comparing pressures with original readings may tell what
the trouble is.
Finding out what is wrong, and getting it working again, can be a
timeconsuming and confusing experience, unless one knows clearly NOTE: The figure below shows where pressure gauges should
how to proceed. be installed. Pressure gauge readings from the original tests
should be recorded for each gauge.
The purpose for this technical guide is to provide simple, step-by-step
guidelines for correcting LP-Gas and anhydrous ammonia pumping It is recommended that the pressure gauges not be used
difficulties. continuously, because vibrations and the ravages of weather
cause their damage or ruin. Therefore, as soon as the initial
The procedure includes a preliminary checklist to help find out if tests are complete, it is best to (1) close the shutoff valves, (2)
the difficulty can be corrected without taking anything apart. Then, remove the gauges, (3) plug the valves and (4) keep the gauges
it shows how to zero in on more serious problems by using a few in a safe place, ready for troubleshooting when really needed.
pressure gauges to pinpoint the cause. It is easier to diagnose a problem if the original test results are
available, but don’t panic if they aren’t. You can still solve the
It is recommended that the pumping system be equipped for easy problem without this information, but it requires more time and
pressure gauge installation before trouble occurs. Small manual effort.
shutoff valves can be installed at proper locations, with plugs inserted
in the outlets.

G23
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pumping System Troubleshooting Guide
Be sure to obtain and keep available for quick referral the the other hand, if you have done all of this and still haven’t worked
Manufacturer’s Operation and Service Manuals for the valves, pump, out your problem. feel free to call your local distributor or Engineered
meter and all operating equipment in the system. Controls International, Inc.

To avoid delays, maintain a complete stock of recommended spare direct. We will do our best to help. Perhaps, between us, we will be
parts on hand for quick repairs. able to solve your problem and add something new to the procedure
which could help everyone in the future.
Follow the steps as shown. Don’t assume the answer is known
beforehand, or skip any applicable steps. Rather, be thorough and
methodical and in most instances, you will solve the problem. On

G24
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cross Reference by Part Number

A3213RT200....................................................................................... G14
3200C............................................................................................... G13 A3213RT300....................................................................................... G14
3200L................................................................................................ G13 A3213RT400....................................................................................... G14
A3209D050........................................................................................... G8 A3217FAL160........................................................................................ G9
A3209D080........................................................................................... G8 A3217FAL210........................................................................................ G9
A3209DT050......................................................................................... G8 A3217FAL260........................................................................................ G9
A3209DT080......................................................................................... G8 A3217FAL410........................................................................................ G9
A3212R105......................................................................................... G15 A3217FAR160....................................................................................... G9
A3212R175......................................................................................... G15 A3217FAR210....................................................................................... G9
A3212R250......................................................................................... G15 A3217FAR260....................................................................................... G9
A3212RT105....................................................................................... G15 A3217FAR410....................................................................................... G9
A3212RT175....................................................................................... G15 A3219FA400L...................................................................................... G11
A3212RT250....................................................................................... G15 A3219FA600L...................................................................................... G11
A3213R150......................................................................................... G14 A3219RT............................................................................................. G13
A3213R200......................................................................................... G14 A7883FK............................................................................................. G17
A3213R300......................................................................................... G14 A7883FK............................................................................................. G18
A3213R400......................................................................................... G14 A7884FK............................................................................................. G17
A3213RT150....................................................................................... G14 A7884FK............................................................................................. G18

G25
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
G

G26
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section H
H H

Adapters Connectors and Fittings

H1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY


Except as expressly set forth above, and subject to the limitation of
LIMITED 10 YEAR WARRANTY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
Engineered Controls International, Inc. (“ECII”) warrants to the original WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
purchasers the products and repair kits manufactured by it to be free PARTICULAR PURPOSE, with respect to its products and parts,
from defects in materials and workmanship under normal use and whether used alone or in combination with others. ECII disclaims all
service for a period of 10 years from the date of manufacture. If within warranties not stated herein.
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the LIMITATION OF LIABILITY
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. NOTICE TO USERS OF PRODUCTS

This warranty does not extend to any product or part that is not The Limited Warranty stated above is a factory warranty to the first
installed and used continuously after installation in accordance with purchasers of ECII products. Since most users have purchased
ECII’s printed instructions, all applicable state and local regulations, these products from ECII distributors, the user must within thirty (30)
and all applicable national standards, such as those promulgated by days after the user’s discovery of what user believes is a defect,
NFPA, DOT and ANSI. This warranty does not extend to any product notify in writing and return the product to the distributor from whom
or part that has been damaged by accident, misuse, abuse, failure to he purchased the product/part. The distributor may or may not at
maintain, or neglect, nor does it extend to any product or part which the distributor’s option choose to submit the product/parts to ECII,
has been modified, altered, disassembled, or repaired in the field. pursuant to this Limited Warranty. Failure by buyer to give such
This warranty does not cover any cosmetic issues, such as scratches, written notice within thirty (30) days shall be deemed an absolute and
dents, marring, fading of colors or discoloration. unconditional waiver of buyer’s claim for such defects. Acceptance
of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

H Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
without notice.

H2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
H
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
ACME Adapters....................................................................... H9 Pigtails..................................................................................... H8
ACME Check Connectors....................................................... H6 POL Adapters........................................................................ H11
ACME Plugs............................................................................ H7 POL Plugs............................................................................... H7
Caps and Reducers................................................................. H8 Pressure Gauge Adapter....................................................... H11
Cross Reference by Part Number......................................... H13 Short Type Hose Couplings..................................................... H5
Extended Type Hose Couplings.............................................. H4 Swivel Adapters..................................................................... H10
Filler Hose Adapters................................................................ H7 Unloading Adapters................................................................. H6
Miscellaneous Adapters.........................................................H11

H3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Extended Type Hose Couplings for Vapor and Liquid Service
A7571 and A7575 Series

Application
Designed especially for liquid filling and vapor equalization of LP-
Gas and anhydrous ammonia. The limited travel of the handle on the
tailpiece minimizes spin-off, encouraging cautious removal to properly
bleed off trapped product to assure closure of the filler valve and
hose end valve. The ACME threads are machined on a rugged steel
insert which is permanently cast in the aluminum handle, providing for
durability under repeated use.

UL
®

Features
• Lightweight aluminum handle is contoured and ribbed for added
comfort, easy handling allows for easy make-up.

• Free swivel action between tailpiece and handle allows for easy
make-up.

• Simplified design eliminates an extra joint and provides smooth,


uninterrupted flow.

A7571 Series
Materials
Handle................................................................................. Aluminium
ACME Threads.................................................................... Steel Inlet
H Restraining Ring.......................................................... Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

A7575 Series
Ordering Information
A. B. C.
Part Type Hose Connection Coupling Connection Approx.
Number of Service (M. NPT) (F. ACME) Length
A7575L2* ½”
A7575L3 ¾”
Liquid 1¾”
A7575L4 1”
7”
A7575L5** 1¼”
A7571LA ½”
Vapor 1¼”
A7571LB ¾”
* Includes 7199-33 adapter, shipped loose.
** Includes A7575L5-1 adapter, shipped loose.

H4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Short Type Hose Couplings for Vapor and Liquid Service
3171, 3175, 3181, 3185 and 3195 Series

3175 Series
A3185 Series

Style A Style B
For Liquid Filling For Liquid Filling
UL ®

3171A Series 3191 Series

Style C Style D
For Vapor Equalizing For Vapor Equalizing

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
A. B. C. D. E.
Part Hose Connection Coupling Connection Tailpiece Hose End Overall
Number Material Style (M. NPT) (F. ACME) Bore To Nut Length
3175B ½” ⁄ ”
35 64

3175 A ¾” 1¾” 2” 2⅞”


Brass ¾”
3175A 1”
3185 1¼” 2¼” 13⁄16” 21⁄16” 3⅛”
Brass Nut & Steel B
3195 2” 3¼” 1 ⁄ ”
13 16 2⅛” 3⅝”
Nipple
A3175 ¾”
A 1¾” ¾” 2” 2⅞”
A3175A 1”
Steel
A3185 1¼” 2¼” 13⁄16” 2⅛” 3⅛”
B
A3195 2” 3¼” 113⁄16” 2⅛” 3⅝”
3171 ⅜” 13⁄32”
1¼” 13⁄16” 27⁄16”
3171A ½” 17⁄32”
C
3181 Brass ¾” 11⁄16” 2” 3¼”
1¾”
3181A 1” 15⁄16” 1⅞” 3⅛”
3191 D 1¼” 2¼” 3⁄16” 2⅛” 35⁄16”

H5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ACME Check Connectors for Lift Trucks 7141F and 7141M
Application
These brass connectors are especially designed to join the carburetor
fuel line to the service valve on lift truck cylinders. Sturdy, long lasting
ACME threads allow quick, hand-tight assembly that provides for
quick and simple cylinder replacement. Back checks automatically
close in each connector when disconnected.

The 7141M couples directly to the service valve. An integral O-ring is 7141M 7141F
designed to seal before the internal check opens, aiding in product
loss prevention. A gasket at the ACME thread is a secondary seal
when the connectors are tightened together. The connector fits
RegO® lift truck cylinder filling adapters for fast, convenient filling.

The 7141F accepts fuel line adapter and couples directly to the
7141M. The O-ring seal in the 7141M is designed to seal before the
internal check opens to allow product to pass through the connection.
The knurled coupling eases threading and the ACME threads provide
rapid effortless make-up, even against LP-Gas pressure. PRODU

10
O

CT
RE

S
NOTE: Refer to the “Cylinder and Service Valves” section of the
UL

10

Y
NT
E
L-500 catalog for additional information.

Y
AR A
WA R R ®

Ordering Information
Protective Cap*
A. B.
Part Number Application Inlet Outlet Rubber Brass
7141M Service Valve ⅜” F. NPT 1¼” M. ACME 7141M-40 7141FP
7141F Fuel Line 1¼” F. ACME ¼” F. NPT - -
* Recommended to minimize foreign material entering valves which could result in leakage.

Unloading Adapters for Container Evacuation 3119A and 3120


Application
H
Designed to provide an efficient means of evacuating an LP-Gas
container for relocation or repair. They thread directly onto the 13⁄4”
ACME male hose connection of RegO® Filler Valves used on RegO®
Double Check Filler Valves and Multivalves®.

The unloading adapters can be used to withdraw liquid provided the


container is equipped with a dip pipe extending from the filler valve to
the bottom of the container.

Features 3119A

• Available in either angle or in-line type configurations.

• Built-in vent valve provides for a controlled release of gas which 3120
may be trapped within the unit after use and also helps to indicate
closure of the Filler Valve.

• Integral plunger has two different lengths of travel, ¼” and ½”,


depending on which way the lever is turned. Can be used with all
RegO® Filler Valves.
PRODU

10
O

UL
G

CT
RE

®
10

Y
NT

Materials
Y

AR
WA R RA

Body............................................................................... Brass
Plunger............................................................................ Steel

Ordering Information 3121

Part Number Style A. Filler Valve Connection B. Hose Connection


3119A In-Line 1¾” M. ACME
3120 1 ¾” F. ACME
Angle ¾” F. NPT
3121

H6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Filler Hose Adapters 3179A and 7577V
These adapters are designed with minimal flow restriction and
recommended for use on the outlet of the LP-Gas delivery truck filler
hose. If the controlled bleed off of the connection indicates the filler
valve on the tank being filled has failed to close, the hose adapter
should be left in place on the filler valve and disconnection should
be made at the regular filler hose coupling. (Repair of the filler valve
must be made as soon as possible). An integral check valve in these
adapters helps prevent further loss of product. The standard filler
3179B valve cap should be attached to these adapters when left on the
container.
PRODU

10
O

CT
RE
UL

S
10

Y
NT
® E

Y
AR A
WA R R

Ordering Information
Built-in Vent A Filler Valve B Hose
Part Number
Valve Connection Connection
7577V Yes
1¾” F. ACME 1¾” M. ACME
3179B No

7577V

ACME Plugs
Specifically designed to withstand the everyday abuse given hose
C5763N
end valves on delivery trucks and hose end couplings on risers in
bulk plants. These rugged plugs protect the coupling tip as well as
prevent the entrance of dirt, dust, snow and rain. They also prevent
possible gas contamination from these same sources. The heavily
ribbed outer surface permits hand-tight make-up.
H
These plugs are available in a choice of four sizes which may be
used with liquid as well as vapor type couplings. As a convenience,
the nylon plugs have a retaining chain and ring to prevent loss during Ordering Information
a transfer operation. A
Part Number Material (M. ACME) Chain & Ring Fits Pipe Size Up To:
All are suitable for LPG or anhydrous ammonia service except the C5763N 1¼” ¾”
brass 5765PR, which is for LP-Gas only. Nylon
C5765N 1¼”
PRODU
1¾”
UL 10
O
5765PR Brass Not Applicable
G

CT
RE

Not intended for use as pressure closures.


S

®
C5767N 2¼” 1¼”
10

Y
NT

E
Nylon
Y

AR A
WA R R
C5769N 3¼” 2”

POL Plugs

PRODU

10
O
G

CT
RE

UL
10

Y
NT

E
Y

AR A ®
WA R R

10538P
(Has hole for attaching
wire to prevent loss of
plug) 3705RC
N970P W/Chain & Ring

Highly recommended for installation in LP-Gas cylinder valve POL Ordering Information
outlets whenever the service line is disconnected or when the cylinder
Part
is being transported.
Number Material Connection

When properly installed, the POL plug is designed to prevent N970P Cycolac
M. POL
contamination of the valve outlet and guards against product leakage 10538P
Brass (CGA 510)
if the cylinder valve is accidentally opened. 3705RC

H7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Caps and Reducers
Ordering Information
Cap With Chain & Ring
Part Ring Fits Pipe Cap Only Part Thread
Number Size Up To: Number Material Connection 907FP
A5776
3144-91 3144-9P 1¼” F. ACME Reducer Coupling
¾” 7141FP Cap Plug
3174-91 Cycolac
3174-9P
3174-93 1¾” F. ACME
1¼”
A8016-93 A8016-9P Nylon
1708 ¾” F. POL (CGA 510)
7141FP 1¼” F. ACME
1¼” -
3175P 1¾” F. ACME
Brass 1708C POL Cap
3184-90 2” 2¼” F. ACME
3194-90 3” 3194-9 CGA 510
3¼” F. ACME
- - 5776* 3194-90G ACME Cap with
A3184-90 2” 2¼” F. ACME Stainless Steel Flange
-
A3194-90 3” Steel
3¼” F. ACME
- - A5776*
907FP 1” - Brass 115 16 ” F. ACME
* Reduces to 13⁄4” M. ACME
PRODU

10
O
G

CT

3144-91
RE

UL Plastic Cap 3144-90


10

Y
NT

E
Y

3175P Cap Plug


AR A
WA R R
Metal Cap
®

Copper Pigtails
612J Series Gauge Tail 0-300 PSIG
PRODU
Pressure Gauge
10
O

Features UL
G

CT
RE

150 150
120 180 120 180
10

90 210
R

® 90 210
R
NT

E 612-PG 612-PG
Y

AR A 60 240 60 240
WA R R
30 270

• Heavy duty construction.


30 270

0 300 0 300

1/4” NPT
• Individually soldered connections to the copper tubing. POL (CGA 510)
• Each pigtail is individually tested prior to shipment.
H
Materials
Fully Retained Bleeder Valve
Flat Blade Screw Slot
Tubing...................................................................................... Copper
Connections............................................................................... Brass 0-300 PSIG
612P Series Gauge Tail Pressure Gauge
150
120 180

912JS12 90 210
R

612-PG
60 240

30 270

0 300

POL (CGA 510)


POL (CGA 510)
... ECII
...

Straight Pigtails
R
MA

Ordering Information
Fully Retained Bleeder Valve
Part Number Flat Blade Screw Slot
¼” Tube ⅜” Tube
⅞” Hex
Approximate ⅞” Hex 1⅛” Hex Short
Connections Length Short Nipple Long Nipple Nipple
5” - ½” 913JS05
12” 912PS12 - 913PS12
[Link] x 20” 912PS20 912PA20 913PS20 913JS05A
[Link] 30” 912PS30 - 913PS30 913PS05A
36” 912PS36 912PA36 913PS36
Bent Pigtails
48” 912PS48 912PA48 913PS48
12” 912FS12 - - Ordering Information 913PS12G

¼” Inverted 20” 912FS20 912FA20 - Part Number


Flare x [Link] 30” 912FS30 - -
⅜” Tube
36” 912FS36 - -
5” - - 913JS05 Approximate ⅞” Hex Short Type/Degree of
¼” [Link] x 12” 912JS12 - - Connections Length Nipple Bend
[Link] 20” 912JS20 - - ¼” M. NPT x M.
913JS05A
36” 912JS36 - - POL 5” 90°
½” [Link] x 913PS05A
12” - - 913LS12
[Link] M. POL x 913PS12G 270° Right Hand
½” [Link] x M. POL 12” 913PS12H 270° Left Hand
12” - - 913KL12
⅜” [Link] 913PS12S 360°

H8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ACME Adapters
Ordering Information
PRODU
For Spare

10
O

UL

CT
RE
D Gasket

S
®
Part A B C Overall E Order

10

Y
NT
E

Y
AR A
Number Material M. ACME MNPT Hex Length Diameter Part No. WA R R

5764A ¼” 1½” D
5764B ⅜”
A2697-
5764C 1¾” ½” 1¾” ¾”
1⅞” 20R
5764D ¾”
5764E 1”
Brass
5766E 1” A B C
2¼” 2¼” 2 5
16 ” 1⅜” A3184-8R E
5766F 1¼”
5768G 1½”
5768H 3¼” 2” 3½” 3⅝” 2⅛” A3194-8R
5768J 2½”
A5764D ¾” A2697- Gasket (Furnished with adapter)
1¾” 1¾” 2 3 16 ” ¾”
A5764E Steel 1” 20R
ACME x Female NPT
A5768H 3¼” 2” 3¼” 3¼” 1 13 16 ” A3194-8R

Ordering Information
For Spare
D Gasket
Part A B C Overall E Order
Number Material M. ACME F. NPT Hex Length Diameter Part No.
5763D 1¼” ¾” 1¼” 1¾” 7
16 ” A2797-20R
5765D ¾” 1⅞” 11
16 ” D
5765E 1¾” 1” 1¾” A2697-20R
2⅛” ¾”
5765F 1¼”
5767F 1¼” 1 3 16”
Brass 2¼” 2 5
16 ”
5767G 2¼” 1½” 1⅜” A3184-8R
A E B C
5767H 2” 2⅜” 2 7 16 ” 1 25 64”
5769H
5769J 3¼”
2”
2½”
3⅜”
3¼”
2⅞”
3½”
1⅞”
A3194-8R
H
2⅛”
5769K 3” 3½” 3⅝”
A5765C ½” 17
32 ”
Gasket (Furnished with adapter)
A5765D ¾” 11
16 ”
1¾” 1¾” 2 3
” A2697-20R
ACME x Male NPT
16
A5765E 1” ⅞”
A5765F Steel 1¼” ”
15
16

A5767F 2¼” 1¼” 2¼” 2⅜” 1 3 16” A3184-8R


A5769H 2” 2⅞” 1⅞”
3¼” 3¼” A3194-8R
A5769K 3” 3 13 16 ” 2⅛”

C
Ordering Information
For Spare
Gasket
Part A B C D Order A D A B
Number Material M. ACME F. NPT Hex Diameter Part No.
5765M 1¾” 1¾” 2 1 16 ” ⅞” A2697-20R
5767M Brass 2¼” 2¼” 2 5 16 ” 1 25 64” A3184-8R
5769M 3¼” 3¼” 2¾” 2⅛” A3194-8R
Gasket (Furnished with adapter)
ACME x ACME

Ordering Information C
For Spare
Gasket
Part A B C D Order
Number Material M. ACME F. NPT Hex Diameter Part No.
D B A
A5764W Steel 1¾” ⅜”* 1¼” 1 11 16 ” 2697-20
* 3⁄8” -16 UNC Thread.

ACME x Miscellaneous
(Recommended for securing
hose-end valve when not in use).
H9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Male POL Swivel Adapters
D PRODU D

10
O

UL

CT
RE

S
®

10

Y
NT
E

Y
A
B
AR
WA R R C B
C

A A
970 (CGA 510) POL
970S (CGA 510) POL
Hard Nose POL Soft Nose POL w/60 DMS Orifice

D
D

3188 Series
C B B
C
50-70
Micron
A Filter
(CGA 510) POL A
970AXS
Soft Nose POL w/Excess Flow D 3199W (CGA 510) POL
Heavy Duty Hard Nose POL w/Excess Flow
D
D
C B

C B
C B
A
A 970AW (CGA 510) POL A
970HT (CGA 510) POL
970AX (CGA 510) POL 970JR
Soft Nose POL w/Handwheel
Hard Nose POL w/Excess Flow Hard Nose POL w/Hose Barb Connection

H Ordering Information
Part A B C D Vapor at 100 PSIG Liquid
Number Material Outlet Thread Hex Drill Overall Length Inlet (SCFH) (GPM)
970 ⁄ ”
5 16 2⅜”
- -
970S ⁄ ”
3 16 23⁄32”
970AX ⅞”
¼” 25⁄64” 404 1.10
970AXS
M. NPT ⁄ ”
5 16
3199W 2⁄ ”7 16 450 0.95
970AW
Brass 1⅜” 22⁄32”
970HT ⁄ ”
3 16
- -
¼”
970JR ⅞” ⁄ ”
5 32 2⅝”
Hose Barb
3188A 350 .95
½”
3188B 1⅛” ⁄ ”
5 16 2½” 700 1.9
M. NPT
3188C 1180 2.9
Note: All nipples incorporate wrench hex section.

CGA 555 Swivel Adapters

A
PRODU

10
O
Part A B C D B
G

CT

C
RE

Number Material Outlet Thread Hex Drill Overall Length


UL
S
10

Y
NT

®
12982 ¼” M. NPT E
Y

AR A
WA R R
Brass 1¼” ⁄ ”
3 16 1 ⁄ ”
15 16
12982G 9⁄16” -18NF

D
CGA 555

H10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
POL Adapters

PRODU
B

10
B O

CT
RE

S
10

Y
NT
E

Y
AR A
WA R R

D A C D C

(CGA 510) POL


UL
®
(CGA 510) POL A
Male POL x Female NPT Male POL x Male NPT and SAE Flare
Ordering Information
Part A B C D
Ordering Information
Number Material Hex Diameter
Part A B C D ⅜”
Number Material M. ACME Hex Diameter 2906D 15
16 ” 11
32 ”
M. NPT
2 1
16 ”
2906A ¼” 1⅜” 15
” 16 ⅜”
Brass ¼” 2906F Brass
2906G ½” 2” 1⅛” SAE Flare
⅞” 9
32 ”
½”
2906E 2¼”
SAE Flare
B
B

CGA 510 D
A C
(POL) CGA 510 D
(POL) A C Female POL x Male NPT

Female POL x Female NPT and Female POL

Ordering Information
Ordering Information
A B C D
Part A B C D Part Number Material Hex Diameter

H
Number Material Hex Diameter
5761A ¼” 3
16 ”
5760Z ⅛” 5

16 5761B ⅜” 13
32 ”
5760A ¼” 13
32 ”
Brass 1⅝” 1⅛”
1⅝” 1⅛” 5761C ½” 7
5760B ⅜” 35
64 ”
16 ”
Brass 5761D ¾”
43
5760C ½” 64 ”

5760D ¾” 1⅞” 1⅜” 13


32 ”
5760S POL (CGA 510) 2⅛” 1⅛”

11⁄8” B
⁄”
78

Hose
Adapter Ordering Information
For use with fuel Part A B
gases (LP-Gas, 1⁄4” ⁄ ” Hex.
9 16
Number Material
5⁄8”

Acetylene). Hex.
Female
15774-1 Brass ¼” M. NPT Inverted
A B Flare
A
Ordering Information Female Inverted Flare
x Male NPT
Part A B B
Number Material
1300 Brass 9
16 ”-18NF (L.H.) ¼” M. NPT
D

23⁄16”
B A
C
Pressure E
Gauge Adapter
11⁄4”
Hex.
A

C
F
Ordering Information Ordering Information
Part Part
Number Material A B C Number Material A B C D E F
1494-1 Brass ½” F. NPT ¼” F. NPT ½” M. NPT 1328 ⅝” - 18 UNF ⅝” - 18 UNF ¼”
13

16 2” 1½”
1331 Brass ¾” - 16 UNF ¾” - 16 UNF Hose 15
16 ” 2⅛”
Barb 1¾”
1332 ⅞” - 14 UNF ⅞” - 14 UNF 1 1 16 ” 2½”

H11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Hose End Valve Adapter
7576

Application
No gas flow is allowed when this adapter is not connected to the 1¾”
ACME connection of a filler valve, it also acts as a back check.

UL ®

Features
• Designed to be installed on the outlet connection of LP-Gas hose
end valve; no flow is allowed until the 7576 adapter female ACME
connection is engaged on to the male ACME threads on the filler
valve.

• Incorporates a back check that will stop flow out of a filler valve that
fails to close, when the 7576 adapter remains connected to the
filler valve.

• Bleeder valve is designed to vent gas between the hose end valve
connection and 7576 hose end adapter.

• Long grip ACME swivel for ease in connecting and disconnecting


from a filler valve connection.

7576

Materials
H
Body........................................................................................... Brass
Inlet Connection......................................................................... Brass
Outlet Connection....................................................................... Brass
ACME Swivel....................................................................... Aluminum
Spring.......................................................................... Stainless Steel
Seat Disc.................................................................. Synthetic Rubber
O-Rings.................................................................... Synthetic Rubber

4.0

PRODU 4.1

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Filler Connection Hose End Valve Connection Propane Liquid Capacity @
Part Number Vent Valve
80 PSID
7576 Yes 1¾” F. ACME 1¾” M. ACME 57 GPM

H12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cross Reference by Part Number
12982..............................................................................................H10 5765D...............................................................................................H9
10538P..............................................................................................H7 A5765E................................................................................................H9
1300................................................................................................H11 5765E................................................................................................H9
1328................................................................................................H11 A5765F................................................................................................H9
1331................................................................................................H11 5765M...............................................................................................H9
1332................................................................................................H11 C5765N...............................................................................................H7
1494-1.............................................................................................H11 5765PR.............................................................................................H7
15774-1...........................................................................................H11 5765F................................................................................................H9
1708..................................................................................................H8 5766E................................................................................................H9
2906A..............................................................................................H11 5766F................................................................................................H9
2906D.............................................................................................H11 A5767F................................................................................................H9
2906E..............................................................................................H11 5767F................................................................................................H9
2906F..............................................................................................H11 5767G...............................................................................................H9
2906G.............................................................................................H11 5767H...............................................................................................H9
3119A................................................................................................H6 5767M...............................................................................................H9
3120..................................................................................................H6 C5767N.............................................................................................H7
3121..................................................................................................H6 5768G...............................................................................................H9
3144-91.............................................................................................H8 A5768H...............................................................................................H9
3144-9P............................................................................................H8 5768H...............................................................................................H9
3171..................................................................................................H5 5768J................................................................................................H9
3171A................................................................................................H5 A5769H...............................................................................................H9
3174-91.............................................................................................H8 5769H...............................................................................................H9
3174-93.............................................................................................H8 5769J................................................................................................H9
3174-9P............................................................................................H8 A5769K................................................................................................H9
3175..................................................................................................H5 5769K................................................................................................H9
A3175..................................................................................................H5 5769M...............................................................................................H9
A3175A................................................................................................H5 C5769N...............................................................................................H7
3175A................................................................................................H5 5776..................................................................................................H8
3175B................................................................................................H5 A5776..................................................................................................H8
3175P................................................................................................H8 7141FP.............................................................................................H8
3179B................................................................................................H7 A7571LA..............................................................................................H4
3181..................................................................................................H5 A7571LB..............................................................................................H4
3181A................................................................................................H5 A7575L2..............................................................................................H4
A3184-90..............................................................................................H8 A7575L3..............................................................................................H4
3184-90..............................................................................................H8 A7575L4..............................................................................................H4
3185...................................................................................................H5
A3185..................................................................................................H5
A7575L5..............................................................................................H4
7576................................................................................................H12 H
3188A..............................................................................................H10 7577V................................................................................................H7
3188B..............................................................................................H10 A8016-93.............................................................................................H8
3188C.............................................................................................H10 A8016-9P............................................................................................H8
3191..................................................................................................H5 907FP...............................................................................................H8
3194-9...............................................................................................H8 912FA20............................................................................................H8
A3194-90.............................................................................................H8 912FS12...........................................................................................H8
3194-90.............................................................................................H8 912FS20...........................................................................................H8
3195..................................................................................................H5 912FS30...........................................................................................H8
A3195..................................................................................................H5 912FS36...........................................................................................H8
3199W.............................................................................................H10 912JS12............................................................................................H8
3705RC.............................................................................................H7 912JS20............................................................................................H8
5760A..............................................................................................H11 912JS36............................................................................................H8
5760B..............................................................................................H11 912PA20...........................................................................................H8
5760C.............................................................................................H11 912PA36...........................................................................................H8
5760D.............................................................................................H11 912PA48...........................................................................................H8
5760S..............................................................................................H11 912PS12...........................................................................................H8
5760Z..............................................................................................H11 912PS20...........................................................................................H8
5761A..............................................................................................H11 912PS30...........................................................................................H8
5761B..............................................................................................H11 912PS36...........................................................................................H8
5761C.............................................................................................H11 912PS48...........................................................................................H8
5761D.............................................................................................H11 913JS05A..........................................................................................H8
5763D...............................................................................................H9 913PS05A.........................................................................................H8
C5763N...............................................................................................H7 913PS12G........................................................................................H8
5764A................................................................................................H9 913PS12H.........................................................................................H8
5764B................................................................................................H9 913PS12S.........................................................................................H8
5764C...............................................................................................H9 970..................................................................................................H10
A5764D...............................................................................................H9 970AW............................................................................................H10
5764D...............................................................................................H9 970AX.............................................................................................H10
A5764E................................................................................................H9 970AXS...........................................................................................H10
5764E................................................................................................H9 970HT.............................................................................................H10
A5764W...............................................................................................H9 970JR..............................................................................................H10
A5765C...............................................................................................H9 N970P.................................................................................................H7
A5765D...............................................................................................H9 970S................................................................................................H10

H13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
H

H14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas & Anhydrous Ammonia Equipment

Section J
J J

Miscellaneous Equipment
(Including Rotogages and ESVs)

J1
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Limited Warranty and Limitation of Liability

LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIABILITY


Except as expressly set forth above, and subject to the limitation of
LIMITED 10 YEAR WARRANTY liability below, ECII MAKES NO OTHER WARRANTY, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
Engineered Controls International, Inc. (“ECII”) warrants to the original WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
purchasers the products and repair kits manufactured by it to be free PARTICULAR PURPOSE, with respect to its products and parts,
from defects in materials and workmanship under normal use and whether used alone or in combination with others. ECII disclaims all
service for a period of 10 years from the date of manufacture. If within warranties not stated herein.
thirty days after buyer’s discovery of what buyer believes is a defect,
buyer notifies in writing and ships the product to ECII at 100 Rego
Drive, Elon, NC 27244, ECII, at its option, and within forty-five days of
receipt , will repair, replace F.O.B. point of manufacture, or refund the LIMITATION OF LIABILITY
purchase price of that part or product found by ECII to be defective.
Failure of buyer to give such written notice and ship the product within
thirty days shall be deemed an absolute and unconditional waiver of
any and all claims of buyer arising out of such defect. NOTICE TO USERS OF PRODUCTS

This warranty does not extend to any product or part that is not The Limited Warranty stated above is a factory warranty to the first
installed and used continuously after installation in accordance with purchasers of ECII products. Since most users have purchased
ECII’s printed instructions, all applicable state and local regulations, these products from ECII distributors, the user must within thirty (30)
and all applicable national standards, such as those promulgated by days after the user’s discovery of what user believes is a defect,
NFPA, DOT and ANSI. This warranty does not extend to any product notify in writing and return the product to the distributor from whom
or part that has been damaged by accident, misuse, abuse, failure to he purchased the product/part. The distributor may or may not at
maintain, or neglect, nor does it extend to any product or part which the distributor’s option choose to submit the product/parts to ECII,
has been modified, altered, disassembled, or repaired in the field. pursuant to this Limited Warranty. Failure by buyer to give such
This warranty does not cover any cosmetic issues, such as scratches, written notice within thirty (30) days shall be deemed an absolute and
dents, marring, fading of colors or discoloration. unconditional waiver of buyer’s claim for such defects. Acceptance
of any alleged defective product/parts by ECII’s distributor for
replacement or repairs under the terms of ECII’s Limited Warranty in
no way determines ECII’s obligations under this Limited Warranty.

J Because of a policy of continuous product improvement, ECII


reserves the right to change designs, materials or specifications
without notice.

J2
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Foreword
This catalog describes a complete line of equipment available from Engineered Controls International, Inc. for use with LP-Gas and
anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:
1. Illustrations and drawings of individual products are representative of “product groups” and all products within a product group
are similar in construction.
2. Materials used for construction of products in this catalog are suitable for rated service pressure at temperatures of -40° F.
to +165° F., unless otherwise specified.
3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.
a. “A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no brass parts).
b. “AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service. These are of partial aluminum
materials and are listed by Underwriters Laboratories (UL) for NH3 service only.
c. All other products are suitable for use with LP-Gas service.
d. “SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 service (i.e., they have stainless steel materials).

Caution Notice
Do not use any product contained in this catalog with any Installation, usage, and maintenance of all ECII® products must
service commodity other than LP-Gas or NH3. If you have be in compliance with all Engineered Controls International,
a need for use of another application, contact Engineered Inc. instructions as well as requirements and provisions of
Controls International, Inc., 100 RegO Drive, Elon, NC 27244, NFPA #54, NFPA#58, DOT, ANSI, and all applicable federal,
(336) 449-7707 before proceeding. state, provincial and local standards, codes, regulations, and
laws.
Proper application, installation and maintenance of products
in this catalog are essential. Users of these products Inspection and maintenance on a periodic basis is essential.
should obtain further information if there are any doubts or Installation and maintenance should be performed only by
questions. qualified personnel.
Be sure all instructions are read and understood before
installation, operation and service.
Warning
All ECII ® products are mechanical devices that will
eventually become inoperative due to wear, corrosion and Filters
aging of components made of materials such as rubber.
The environment and conditions of use will determine the ECII® LP-Gas equipment is designed to operate in a system
J
safe service life of these products. Periodic inspection free from contamination. A variety of in-line filters are
and maintenance are essential to avoid serious injury and commercially available to the LP-Gas industry for installation
property damage. in domestic systems.
The use of an in-line filter should be considered when
Many ECII® products are manufactured for storage, transport, other system components may be unclean and the system
transfer and use of toxic flammable and dangerous liquids and contaminated by rust, scale, dirt, debris or other foreign
gases. Such substances should be handled by experienced material.
and trained personnel only, using accepted governmental
and industrial safety procedures. Never vent LP-Gas near any
possible source of ignition.

Contents Page
Combination Valve.................................................................. J17 Needle Valves......................................................................... J20
Cross Reference by Part Number.......................................... J21 Pressure Gauges................................................................... J19
Cylinder Filling Systems......................................................... J15 Pull-Away Valves...................................................................... J7
Emergency Shut-Off Valves (ESVs)...................................J8/J11 Quick Connect POL Filling Adapters...................................... J19
ESV Accessories.................................................................... J12 Rotogages®.........................................................................J4/J6
Fixed Liquid Level Gauges..................................................... J18 Sight Flow Indicators.............................................................. J16
Gas Alarms and Detectors..................................................... J20 Spanner Wrench..................................................................... J22
Gritrol Filters........................................................................... J17 Vent Valves............................................................................. J21
Hose-End Adapters..........................................................J15/J16

J3
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
1” Rotogages® for Large Mobile and Stationary Containers
9090 and AA9090 Series

Application
Rotogages® are designed to provide an accurate determination of
LPGas or anhydrous ammonia container contents. They mount in a
standard 1” NPT coupling on large mobile or stationary containers.

To operate the Rotogages®, the vent valve is opened and the dip
tube rotated slowly from the container vapor space to the liquid
space. The difference in appearance of the discharge indicates when
the liquid level is reached. Dial readings then indicate the percentage
of product in the container.

Features
• Supported design (TS Models) eliminates whipping and the need
for internal support hangers.

• Resistance-free nylon bearing inserts reduce friction and promote


operating ease.

• Dial face is dual calibrated to provide greater accuracy in reading


contents in containers which are not level.

• Interchangeable accessory dials permit interchangeable service


between LP-Gas and anhydrous ammonia. Rotogage® Assembly

Materials

J Body............................................................................................ Steel
Stem............................................................................................ Steel
Dip Tube..................................................................... Seamless Steel
Indicator......................................................................... Malleable Iron
Dial Plate............................................................................. Aluminium
Vent Stem.................................................................... Stainless Steel

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

A9091-18LX

UL
®

Rotogage® Dials

Ordering Information
Part Number Service Container Size
A9091-18L LP-Gas All Sizes
A9091-18LX* LP-Gas Over 1200 U.S. gallons
A9091-18N NH3 All Sizes

* Dial permits higher filling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4-5.2.1

J4
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
1” Rotogages® for Large Mobile and Stationary Containers

For Small Mobile or Stationary Containers


9091RM and 9092RM Series

UL ®

For Large Stationary Containers


9093RSM, 9094RSM and 9095RSM Series

For Large Mobile or Stationary Containers


9093TSM, 9094TSM and 9095TSM Series

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
For Container Inside Diameter
Part Number

For Use With For Use With


LP-Gas NH3 Ellipsoidal Heads Hemispherical Heads
For Mobile For Mobile
or Stationary For Stationary or Stationary For Stationary Side End Side End
Containers Containers Only Containers Containers Only Mounted Mounted Mounted Mounted
9091RM24 - AA9091RM24 - 30” - 45” 30” - 75” 30” - 45” 30” - 45”
9092RM36 - AA9092RM36 - 46” - 61” 76” - 108” 46” - 61” 46” - 61”
9093TSM48* 9093RSM48 AA9093TSM48* AA9093RSM48 62” - 79” 109” - 147” 62” - 79” 62” - 79”
9094TSM60* 9094RSM60 AA9094TSM60* AA9094RSM60 80” - 99” - 80” - 99” 80” - 99”
9095TSM72* 9095RSM72 AA9095TSM72* AA9095RSM72 100” - 147” - 100” - 147” 100” - 147”
* Supported Design
NOTE: The dip tube must be cut to the required length (1⁄2” of container inside diameter minus 53⁄4”).

J5
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
¾” Rotogages® for Small Stationary and Mobile LP-Gas Containers
2070 Series

Application
Rotogages® are designed to provide accurate determination of
LP-Gas container contents. They may be end or side mounted in
a standard ¾” NPT coupling on stationary or mobile containers.
UL®

To guarantee accurate measurement, they should not be used on


stationary containers that exceed 60” I.D. or on mobile containers,
subject to vibration, with an I.D. of more than 24”.

Features
• Provides long, trouble-free performance and ease of operation.

• Polished stems assure bind-proof operation.

• Dial face is dual calibrated to provide greater accuracy in reading


contents in containers which are not level.
2070 Series

Materials
Body........................................................................................... Brass
Stem............................................................................... Brass Tubing
Dip Tube........................................................ Seamless Brass Tubing
Dial Plate............................................................................. Aluminium
Indicator......................................................................... Malleable Iron

PRODU

10
O

J
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number
For Containers with Inside
Rotogage® Dip Tube Diameter Tank Connection Valve Seat Orifice
2071-L25.7 Up to 40” No. 54
2070CO ¾ M. NPT
2071-L39.7 Up to 60” Drill Size

NOTE: The dip tube must be cut to the required length (1⁄2 of container inside diameter minus
1⁄2”), when mounted on center line of tank.

J6
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Pull-Away Valves for Transfer Operations
A2141 Series

Application
Designed especially to provide pull-away protection for LP-Gas and Materials
anhydrous ammonia transfer operations including transport and
delivery truck loading and unloading, engine fuel container filling and Body (¾”, 1”)................................................... Cadmium Plated Steel
miscellaneous cylinder filling operations. When properly fastened to Body (1¼”, 2”)..................................................................... Aluminum
the inlet end of the discharge hose, the valve is designed to stop gas Seals.......................................................................... Buna-N Rubber
escape from both upstream and downstream lines in the event of a Cables.............................................. Nylon Coated, Galvanized Steel
pull-away. An excessive tension pull causes the valve to automatically
separate, closing two internal back pressure checks. Only a few cubic
centimeters of gas escape at the instant of separation.

It is recommended that a convenient means be provided to safely


remove the pressure from the line upstream of each coupling half to
enable reassembly of the valve. To reassemble, simply push the male
half firmly into the female half until the retaining balls slip into the
retaining groove. Check for leaks after reassembly.

NOTE: It is recommended that pull-away valves be maintained and A2141A6


safety tested perodically to confirm that they will separate properly in
the event of a pull-away. Lubrication every six months is essential to
the pull-away’s operation. Dry nitrogen or other inert gas is suggested
as a source of pressure for pull-away tests.
A2141A10
If the A2141 pull-away valve is going to be stored for a period of time,
A2141 Series such as in seasonal applications, it is recommended
that it be sprayed with a good grade of rust-preventive machine oil,
and covered to protect it from moisture.

Features
J
• Heavy-duty construction for long service life.

• A “true’’ pull-away type valve which simply reconnects by snapping


together without unnecessary downtime or need for new parts.

• Buna-N seals provide leak tight operation.

• 400 PSIG operating pressure.

PRODU

10
O
G

CT
RE

UL
S
10

®
NT

E
Y

AR A
WA R R

Ordering Information
LP-Gas Liquid Flow Capacity at Various Differential Pressures
Inlet/Outlet Disconnect Reconnect (GPM)*
Length Of
Part Number Connections Force Force
Valve
NPT F. Approx-lbs Approx-lbs 5 PSIG 10 PSIG 25 PSIG 50 PSIG

A2141A6
¾” 130 80 37⁄8” 11 16 25 36
A2141A6L**
A2141A8
1” 75 50 49⁄16” 21 30 47 67
A2141A8L**
A2141A10 1¼” 160 25 55⁄8” 52 75 120 170
A2141A16 2” 300 50 145⁄16”” 250 350 550 750
* To Determine NH liquid flow capacity, multiply by .90.
3

J7
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Emergency Shut-Off Valves (ESV’s)
Why and how they should be used for Bobtail Filling Section 2-4.5.4 Emergency shutoff valves shall be approved and
and Transport Unloading. incorporate all the following means of closing:

General Information (a) Automatic shutoff through thermal (fire) actuation. When fusible
The primary purpose of Emergency Shut-Off Valves in bobtail filling elements are used they shall have a melting point not exceeding 250°
and transport unloading is to allow quick shut-off of liquid and vapor F. (121° C).
flow in the event there is an accidental pull-away of a truck or a hose
rupture, both of which could cause a fire. (b) Manual shutoff from a remote location.

A system using Emergency Shut-Off Valves will not prevent some (c) Manual shutoff at the installed location.
spillage of liquid and vapor, but the total system should be constructed
so this spillage will be kept to a minimum. This provision sets for the basic criteria for the emergency shutoff
valve, a key valve in the protection of many liquid transfer operations.
Actuating means for remote control may be electrical, mechanical or
This can be accomplished either by making possible, quick action pneumatic.
by the driver or plant personnel in closing the valves by manual
remote or pneumatic remote actuation; or in case of a pull-away, by Many systems use a pneumatic system where the tubing itself acts
automatic closing of the liquid valve by means of a cable connected as a fusible element releasing the pressure holding the valve open.
to the liquid hose. With respect to the feature of manual shutoff at the installed location,
it is recommended that this valve be operated occasionally. Also, the
By minimizing the presence of liquid and vapor, the chance of a fire or system should be tested periodically to determine that it will function
explosion will be reduced. In case of a fire, thermal links at the valves properly.
or at other appropriate locations could close the valves and prevent
further release of liquid and vapor. Section 3-2.7.9 on new installations, and by December 31, 1980
on existing installations, (1) stationary single container systems of
The valve closing systems will be discussed later in this section. The over 4,000 gal. (15.1 m3) water capacity, or (2) stationary multiple
user should decide which system is most appropriate, depending on container systems with an aggregate water capacity of more than
the piping configuration and the general layout of the filling/-unloading 4,000 gal. (15.1 m3) utilizing a common or manifolded liquid transfer
area. line, shall comply with 3-2.7.9 (a) and (b).
ESV Application for Bobtail Loading and Transport Unloading (a) When a hose or swivel type piping 11⁄2” or larger is used for liquid
transfer or a 11⁄4” or larger vapor hose or swivel type piping is used
A very important function of the typical LP-Gas storage plant is to in this service (excluding flexible connectors in such liquid and vapor
transfer LP-Gas into bobtails for delivery to customers. How efficiently piping), and emergency shutoff valve complying with 2-4.5.4 shall be
and rapidly these bobtails can be filled often determines the number installed in the fixed piping of the transfer system within 20 ft (6m) of
of customers that can be served each day, as well as how many lineal pipe from the nearest end of the hose or swivel type piping to
J bobtails are required to satisfactorily serve all customers. Therefore,
the selection of an ESV for the bobtail liquid loading line should be
which the hose or swivel type piping is connected. The preceding
sizes are nominal. Where the flow is only in one direction, a backflow
done with care so as to maximize efficiency in filling and have year- check valve may be used in lieu of an emergency shutoff valve if
round dependability. installed in the fixed piping down-stream of the hose or swivel type
piping, provided the backflow check valve has a metal-to-metal seat
The RegO® 2” liquid ESV (7605B) has a full open port so that the or a primary resilient seat with a secondary metal seat not hinged
restrictions of flow would be no more than you would expect through with combustible material. When either a liquid or vapor line has two
an equivalent length of 2” schedule 80 pipe. To improve the overall or more hoses or swivel type piping of the sizes designated, either an
efficiency of the system, the valve was also designed as an operating emergency shutoff valve or a backflow check valve shall be installed
valve so it could replace an existing globe or angle valve already in each leg of the piping.
installed at the end of the fixed piping. Thus, installing a RegO® ESV
could actually result in a more efficient pumping operation than the (1) Emergency shutoff valves shall be installed so that the temperature
existing system. sensitive element in the valve, or a supplemental temperature
sensitive element [250° F. (121° C) maximum] connected to actuate
Equally important in the consideration of an ESV is its performance in the valve, is not more than 5 ft. (1.5 m) from the nearest end of the
an emergency, especially bobtail pull-aways. According to the NPGA, hose or swivel type piping connected to the line in which the valve is
it is the bobtail filling transfer process that produces almost 99% of all installed.
bulk plant accidents and fires. Therefore, when selecting the proper
ESV for bobtail filling, also consider the dependability of performance, (b) The emergency shutoff valve(s) or backflow check valve(s)
and simplicity of operation and maintenance. specified in 3-2.7.9 (a) shall be installed in the plant piping so that any
break resulting from a pull will occur on the hose or swivel type piping
The RegO® ESV clearly indicates to the operator its open or closed side of the connection while retaining intact the valves and piping on
position. It allows full manual control by the operator and provides the plant side of the connection. This may be accomplished by use
means for remote operation in emergencies from either in front of the of concrete bulkheads or equivalent anchorage or by the use of a
valve or in the rear. weakness or shear fitting. Such anchorage is not required for tank
car unloading.
No complicated systems of pulleys and cables are necessary since
direct, straight pulls will close the valve. Means are even provided
to secure a length of cable to the transfer hose so as to produce These provisions have been interpreted by the National Propane Gas
an automatic closing in the event the driver pulls away without Association as to how bobtail filling and transport unloading stations
disconnecting the hose. should be configured. The diagrams shown here are in essential
conformance with NPGA Bulletin 128-77.
NFPA Provisions (1986)

The pertinent provisions of NFPA Pamphlet 58, as they apply to


Emergency Shut-Off Valves and how they are to be installed, are as
follows:

J8
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
LP-Gas Emergency Shut-Off Valves (ESV’s)

Installation Compliance with NFPA Requirements


vapor system is this: If the vapor flow is out of the storage tank, an
A valve that is approved as an ESV may be installed in the fixed ESV is required. ESV systems are designed to protect the storage
piping up to a distance of 20 feet (along the pipe) from the point tank contents against uncontrolled release.
where the transfer hose is attached to the fixed piping.
Therefore, a bobtail loading system could use a 11⁄4” or larger back
However, when the ESV is located more than five feet from the end of pressure check valve in the vapor system since the flow of vapor
the fixed piping, an additional fusible element must be installed within is always from the bobtail being filled back to the storage tank. To
five feet of the point of attachment of the hose, and be connected to improve transfer rates, the use of the RegO® 6586B back check
the ESV valve in such a manner that it will cause the ESV to close in valve at this location would provide protection at minimum pressure
the event of a fire. drop.
J
The ideal location of the ESV is as close to the end of the fixed If the bobtail vapor line is also used when unloading transports, then
piping as possible. This position eliminates the need for an additional the RegO® 7781AF ESV should be used. The 7781AF provides
fusible element and cable, and it may also permit the elimination of a thermal protection, manual closing and a remote emergency closing
restrictive valve already installed at the end of the fixed piping. system similar to the RegO® 2” liquid ESV, 7605B.

To this point, our comments have been principally concerned with Remote Control Systems
ESV protection of the liquid line at bulk plants because this is the
area of greatest potential danger in the event of a pull-away or hose Usually in transfer loading operations, the valve handles and cables
rupture. are located in close proximity to the area of greatest potential danger
during an emergency. Therefore, each bobtail filling system or
However, regulations also require an ESV in the vapor transfer line transport unloading system should have installed in it at least one
when the vapor hose is 11⁄4” or larger. A helpful rule of thumb in readily accessible, alternate remote operating device.
determining whether or not an ESV control valve is required in your

Figure 2
RegO® ESV’s with Remote Pneumatic
and Transfer Hose Cable Release
Systems Typical Installation
J9
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
2” & 3” Swing-Check ESVs for Bulk Plants
6016 Series and 6024 Series

Application UL
®

Designed for installation in liquid transfer lines at LP-Gas or


Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.
6016
Features
• Fusible Element is located in the thermal fuse assembly which
acts at the latch open and close trigger. When exposed to fire, the
element melts at 212 degrees F. allowing the shaft to return to the
closed position.

• Valve can be opened by use of operating lever, if a pneumatic


actuator is used it will open with the actuator.

• Valve can be closed by remote cable or pneumatic actuator.

• Valve can be closed by simply pushing the operating lever down,


it is not necessary to trip the close trigger.

• Seat is metal protected to minimize leakage in case direct fire


impingement.

• Straight through design allows for a liquid flow of 150 GPM (LPG)
with only a 1 psig drop.

• Quick closing regardless if the pump is running or not.

J Sturdy Rugged Construction 6024


• Will withstand hydraulic shock of sudden closings, piping strains,
and temperature variations.

• Valve has only two moving parts, stem and close/thermal trigger.

• 6016 is UL listed for use in LP-Gas as an emergency and


operating shut-off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.
Materials
Body............................................................... Ductile Iron Cad Plated
Stem............................................................................ Stainless Steel
Seat............................................................................. Stainless Steel
Seat Disc (6016)............................................. High Temperature Viton
Seat Disc (AA6016).................................................. Synthetic Rubber
Springs........................................................................ Stainless Steel
Gaskets...................................................................................... Teflon

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number For Use With: Inlet and Outlet Connections Liquid Flow Capacity at 10 PSIG Drop (GPM)
6016 LP-Gas 2” F-NPT 711 (LP-Gas)
AA6016 NH3 2” F-NPT 640 (NH3)
6024 LP-Gas 3” F-NPT 1325 (LP-Gas)
AA6024 NH3 3” F-NPT 1173 (NH3)

J10
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
1¼” Swing-Check ESV for Bulk Plants
6010 and AA6010

Application
Designed for installation in liquid or vapor transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.

Features
Meets NFPA 58 and UL requirements

• Fusible Element is located in the thermal fuse assembly, which acts


at the latch open and close trigger. When exposed to fire, the
element melts at 212 degrees F. allowing the shaft to return to the
closed position.

• Valve can be opened by use of operating lever, if a pneumatic


actuator is used it will open with the actuator.

• Valve can be closed by remote cable or pneumatic actuator. 6010

• Valve can be closed by simply pushing the operating lever down; it


is not necessary to trip the close trigger. 9.9

Sturdy Rugged Construction


• Will withstand hydraulic shock of sudden closings, piping strains,
and temperature variations.
3.4

• Valve has only two moving parts, stem and close/thermal trigger.

J
5.2

• 6010 is UL listed for use in LP-Gas as an emergency and operating


shut-off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.

• Seat is metal protected to minimize leakage in case direct fire


impingement.

• Quick closing regardless if the pump is running or not.

9.9 5.7

Materials
Body.............................................................. Ductile Iron Clad Plated
3.4
Stem............................................................................ Stainless Steel
Seat............................................................................. Stainless Steel 5.2
Seat Disc..................................... High Temperature Viton (6010 only)
Seat Disc.......................................... Synthetic Rubber (AA6010 only)
PRODU

10
Springs........................................................................ Stainless Steel O
G

CT

Gaskets...................................................................................... Teflon
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Inlet and Outlet Accessories Liquid Flow Capacity @ 10 PSIG
Part Number For Use With Pressure Drop (GPM)
Connections Remote Pneumatic Close Remote Pneumatic Open/Close
6010 LP-Gas 1¼” F. NPT 259
6016-60D 6016-60C
AA6010 NH3 1¼” F. NPT 233

J11
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
ESV Pneumatic Controls

Application UL
®

RegO® Emergency Shut-Off Valves modified for remote pneumatic


shutdown operation retain all the operating features of the standard
valves.

Once equipped with pneumatic cylinders and then pressurized,


the pneumatic cylinder piston rod disengages from a striker plate,
allowing the ESV to be manually opened and the striker plate to act
as a latch and hold the valve open. Release of the control system
pressure for any reason closes the ESV for fail-safe operation.

Features
Convenience 6016 with 6016-60D Remote Close Actuator

• Closes the liquid and vapor ESV from a convenient remote


location.

• Independent closed loop system allows the ESV to be


pneumatically charged, but opened or closed manually or with
cable controls to conserve pressurized gas.

Reliability

• Independent closed loop system will continue to hold pressure


and close ESV in an emergency - even if supply pressure is cut
off.

Security

J • Any loss of pressure from the control line, such as accidents or


the line melting from fire, automatically shuts down the liquid and
vapor ESV.

• ESV must be reset after automatic shutdown.

PRODU

10
O
G

CT
RE

7605PN-50 Pneumatic Remote Control Kit


10

Y
NT

E
Y

AR A Control kit with components for connecting and charging the


WA R R
pneumatic controls from a source of compressed gas (air or nitrogen)
to a RegO® liquid or vapor ESV. Includes charging valves with low
pressure indicator, operating valves, 100 feet of 1⁄4” plastic tubing
and tube fittings.

Ordering Information
Part Number Description
7781AFPN-1 Cylinder assembly kit to convert 7781AF ESVs to pneumatic shutdown.
6016-60D Cylinder assembly kit to convert 6016 ESVs to pneumatic shutdown.
7605PN-50 Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly
7605APN-8A Extra shutdown valve assembly
7605A-BT 100’ roll of ¼” pneumatic tubing.
7605AP-16 ¼” tubing tee, with nuts.
7605AP-15 ⅛” NPT x ¼” tubing, straight connector.

J12
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Hydraulic Automatic Cylinder Filling System
7194MD and 7194HD
Application
Hydraulic self-contained system.
Designed to provide accurate, economical filling of LP-Gas DOT and No external power required.
fork lift cylinders by weight. Filling stops automatically as the total
weight of the cylinder reaches the amount pre-set on the scale. One
individual can efficiently handle up to four cylinder filling operations
simultaneously, to maximize profits, increase efficiency and allow Shut-off Valve
servicing of more customers.
1
The RegO® automatic cylinder filling system is designed for use with
these scales only: LP-Gas Supply
6 Strainer Hydrostatic Relief Valve
FAIRBANKS-MORSE SCALES
New Style - 1280A Double Beam Scale or Single Beam Scales 3
1124A and 1174A. 7
Old Style - 1280 Double Beam Scale or Single Beam Scale 1123
with or without Howe No. 12108 “Over or Under’’ Indicator. 8 Open

HOWE SCALES
(with or without Howe No. 8325 Balance Indicator)
—No. 54X Wood Pillar and Shelf Scale.
—No. 57 Steel Pillar and Shelf Scale (single beam).
2
—No. 57X Steel Pillar and Shelf Scale (double beam).

Features Closed
4 A,B

• Completely self-contained with no electrical source or wiring


required.
• Works hydraulically, like brakes on a car.
• Filling stops automatically when cylinders reach pre-set weight.
• Up to four stations can be handled by one individual. J
How It Works
The scale beam weight is adjusted to the desired filled weight and the UL
empty cylinder is placed on the scale. The loading hose is connected
®

to the cylinder valve, and the lever on the master cylinder is moved
to the vertical position. When the quick-acting valve on the loading
hose is opened, the cylinder will rapidly fill. The master cylinder lever PRODU

10
O
is designed to trip, move to a horizontal position and automatically G

CT
RE

S
shut off the control valve as soon as the scale reaches the pre-set
filled weight.
10

Y
NT
E
Y

AR A
Components may be ordered separately with piping done by the WA R R
installer. Two completely assembled manifold configurations are also
available.

Ordering Information Hydraulic System Components

Key
No. Description Size Part No.
Assembly for Fairbanks-Morse. Includes items 1 thru 8 below. 7194MD
Assembly for Howe. Includes items 1 thru 8 7194HD
1 Propane Control Valve ½” NPT Female, with ⅛” NPT Female Hydraulic Connection 7177
2 Master Cylinder, with Actuator Lever ⅛” NPT Hydraulic Connection 7188
3 Hydraulic Hose Assembly ⁄ ” I.D. with ⅛” NPT Male Ends, 43½” Overall Length
3 16 7194-1
1-3 Valve, Cylinder and Hose Assembly for Fairbanks-Morse Scales - 7188MS

1-3 Valve, Cylinder and Hose Assembly for Howe Scales - 7188HS

Bracket Kit for Fairbanks Morse Scales, Complete with Screws, Washers, Nuts
4A - 7194M-3A
and Instructions
Bracket Kit for Howe Scales, Complete with Screws, Washers, Nuts and
4B - 7194H-3
Instructions
5 Can of Hydraulic Fluid, Complete with Filling Spout 1½ ounce 7188-21
6 Propane Filling Hose Assembly ½” I.D., with ½” NPT Male Ends. 50½” Overall Length 7193D
7 Quick-acting Shut Off Valve ½” NPT INlet X ¼” NPT Outlet 7901TB
8* Soft Nose Cylinder Connector ¼” NPT Male X POL Male 7193D-10

J13
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Sight Flow Indicators for Bulk Plants
A7794 and A7796

Application UL
®

Designed to promote maximum pump efficiency, these indicators


enable bulk plant operators to visually inspect liquid flow conditions.
With glass on both sides of the indicator, flow can be observed from
either side, even under some poor light conditions. The integral swing
check also serves as a back-check valve to prevent reverse flow and
product loss if the hose fails in a loading operation.

By installing an indicator on the upstream side of the plant pump,


suction conditions can be observed and the pump speed adjusted to
obtain the maximum possible flow rate without cavitation. Additionally,
if an indicator is installed in the piping at the loading rack, just ahead
of the loading hose, the operator can maintain a constant check on
pump conditions.

Both installations are designed to allow for observation to provide


maximum pump efficiency and assure safe plant pump operation.

In compressor operations a sight flow indicator installed in the liquid


line will give a visual indication when the tank car or transport is
emptied. Compressor operation can then be immediately reversed to
start recovery of the vapor A7794

Features
• Durable ductile iron body assures long, trouble-free operation with
design working pressure of 400 PSIG.

• Glass is polished, ground and tempered after fabrication for


J maximum strength up to 2,500 PSIG.

• Set screws minimize loosening of glass retainer rings.

• O-ring glass seals provide for leak-tight operation.

Materials
Body.................................................................................. Ductile Iron
Swing Check............................................................... Stainless Steel
Check Seat Disc........................................ Resilient Synthetic Rubber
Glass............................................... Polished, Ground and Tempered
Tested to 2,500 PSIG.

PRODU

10
O
G

CT
RE

S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
A
Inlet/Outlet B
Part Number Connections Length
A7794 2” F. NPT 5¾”
A7796 3” F. NPT 7⅜”

J14
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Hose End Adapters for DOT Cylinder Filling
7193D-10 and 7193U-10

Application
Designed to provide quick and easy filling of DOT cylinders with POL
UL ®

or Type I connections. This adapter may be used with hydraulic and


electric automatic systems or with manual systems in conjunction
with a RegO® 7901TB Quick Acting Shut-Off Valve.

These filling connectors have an extended connection on the


handwheel, which makes it possible to connect the loading hose to
valves on cylinders with fixed collars. The handwheel is well outside
the collar for easy operation.

PRODU
7193D-10
10
O

CT
RE

S
10

Y
NT
E
7193U-10

Y
AR A
WA R R

Part Number Applications Inlet Connection Outlet Connection Materials


7193D-10
7193U-10
Filling of DOT Cylinders with POL Connections
Filling of DOT Cylinders with Type I Connections
¼” M. NPT
M. POL (CGA 510)
Type 1 Connection (1 ” M. ACME)
Brass & Stainless Steel
Brass
J

Connector for DOT Cylinder Filling Adapter


7193T-10

Application
The 7193T-10 Connector is designed for use on the 7193D-10 Filling
Adapters. Connector allows quick connection to the Type I 15⁄16 M.
ACME threads for operators that fill both POL and Type I valves.

PRODU

10
O
7193T-10
G

CT

UL
RE

®
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Applications Inlet Connection Outlet Connection Materials
7193T-10 Converts 7193D-10 Adapters from POL to a Type 1 Connection M. POL CGA 510 Type 1 Connection (15⁄16” M. ACME) Brass

J15
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Hose End Adapter for Lift Truck Cylinder Filling
7193L-10A

Application
The 7193L-10A is designed to provide quick and easy attachment of
the filling hose to DOT cylinders equipped with RegO® 7141M check
connectors.

The 11⁄4” ACME outlet threads facilitate rapid make-up. When


connected, back-checks in the adapter and check connector
automatically open. Low pressure drop between the two assures high
filling rates. An integral check closes when disconnected, eliminating
the need to close any valves manually to disconnect the charging
hose. 7193L-10A

Because a leak-tight seal is formed before the integral check opens or


closes, product loss is kept to an absolute minimum when connecting
or disconnecting the loading hose.
9 1⁄4”
1 3⁄8”
PRODU 1 1⁄4” ACME

10
O
G

CT
RE

UL
S

®
10

Y
NT

E ⁄ ” NPT
14
Y

AR A
WA R R

Ordering Information
Accessories
Body
Part Number Application Inlet Connection Outlet Connection Material Adapter
7193L-10A Filling of Fork Lift Cylinders* ¼” M. NPT 1¼” F. ACME Brass 5760A

J * The 7193L-10A is intended to be permanently attached to the filling hose.


A 5760A adapter enables the 7193L-10A to be attached to the POL connection on the 7193D-10 at regulator cylinder filling stations to allow for occasional filling of fork lift cylinders.

Lever Operated Hose End Adapter for Fork Lift Cylinder Filling
7193K-10B

Application
Designed to drastically reduce labor and time when continuously
UL®

filling large numbers of lift truck cylinders equipped with RegO®


7141M check connectors.

Rapid make-up is accomplished by simply slipping the adapter yoke


behind the hex wrenching section of the 7141M connector and
depressing the lever. When the cylinder is filled, the adapter is easily 7193K-10B
disengaged by releasing the operating lever. When connected, back
checks in the adapter and connector automatically open. An integral PRODU

10
O
check closes when disconnected, eliminating the need to close any
G

CT
RE

valves manually on the filling manifold to disconnect the charging


10

Y
NT

E
hose. The shut-off valve on the container must be closed after filling. Quick
Y

AR A
WA R R

⁄ ” NPT
14 Disconnect
Yoke
Because a leak-tight seal is formed before the checks close, product
loss is kept to an absolute minimum when connecting or disconnecting
the loading hose.

The 7193K-10B is intended to be permanently attached to the filling


hose.

18 1⁄4”
Ordering Information Approx.

Part Number Application Inlet Connection Outlet Connection Materials


7193K-10B Lever Operated for Quick Filling of Fork Lift Cylinders ¼” F. NPT Quick Disconnect Yoke* Brass and Steel
* For use with RegO® 7141M check connector.

J16
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Combination Valve for Bulk Storage Containers
A2805C

Application
Designed for installation on bulk storage containers, this valve
combines a pressure gauge mounting and provision for a fixed tube
UL
®

liquid level gauge.

The shut-off valve prevents the pressure gauge from being subjected
to constant pressure, thereby prolonging its life and accuracy. The PRODU

10
O
valve may be closed, and the vent valve opened to vent pressure

CT
RE

S
from the gauge to permit replacement.

10

Y
NT
E

Y
AR A
WA R R
For fixed liquid level gauging, the valve can be mounted at the
maximum permitted filling level. When equipped with a dip tube
threaded 1⁄8” [Link], it can be installed at any convenient level.

Materials A2805C

Body 2805C................................................................................ Brass


Body A2805C.................................................................... Ductile Iron
Bonnet......................................................................................... Steel
Valve Stem.................................................................. Stainless Steel
Vent Stem.................................................................... Stainless Steel
Valve Stem Seal........................................ Resilient Synthetic Rubber
Vent Seal................................................... Resilient Synthetic Rubber
Valve Seat.................................................................................. Nylon

Ordering Information
J
Part Number Contianer Connection Service Connection Liquid Level Vent
A2805C ¾” M. NPT ¼” F. NPT for Gauge Mounting Knurled*
* Has 1⁄8” F. NPT opening for installing separate dip tube.

Gritrol Fuel Line Filters


12802

Application
Designed especially for use in liquid motor fuel lines to trap foreign
material which otherwise may damage precision components in the
LP-Gas carburetion system. These filters incorporate an integral
sintered metal filter element in a straight through design.

12802

PRODU

10
O

UL
G

CT
RE

®
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Inlet Connection Outlet Connection
12802 ¼” F. NPT ¼” M. NPT

J17
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Vent Valves 3165C, 3165S and TSS3169
Application
Especially designed to bleed off liquid or vapor pressures trapped
in transfer lines. When installed in the downstream boss of RegO®
globe and angle valves used at the end of a liquid transfer hose,
the bleeder valve allows for the controlled venting of the product
and indicates to the operator that the valves are closed and he can
disconnect the coupling. They may also be used as a fixed liquid level
gauge where the dip tube is part of the container.
3165C 3165S TSS3169
All these valves incorporate a No. 54 drill size orifice.

An optional instruction plate with “Stop Filling When Liquid Appears’’


may be ordered for use with these valves.
PRODU

10
O
1 1⁄8”
G

CT
RE

Materials UL
S
1 1⁄8”
10

Y
NT
E
⁄”
34
Y

AR A
® WA R R

Body (3165)................................................................................ Brass


Body (TSS3169).......................................................... Stainless Steel
1⁄4 ”
Seat Disc (3165)........................................ Resilient Synthetic Rubber ⁄” 14
⁄ ” NPT
14
NPT
Seat Disc (3169)......................................................................... Teflon NPT

Ordering Information
Accessories
Part Number Service Connection Actuation Warning Plate Kit
3165C Knurled
LP-Gas Only
3165S ¼” M. NPT Slotted 2550-40P
TSS3169 LP-Gas & NH3 Tee Handle

Fixed Liquid Level Gauges 3165 Series and TA3169F


J Application Materials
Especially designed to provide a visible warning when containers Body (3165)................................................................................ Brass
are filled to the maximum permitted filling level. At the start of the Body (TA3169)............................................................. Stainless Steel
filling operation, with the vent stem opened, the valve discharges Seat Disc (3165)........................................ Resilient Synthetic Rubber
vapor. When the maximum permitted filling level is reached, the valve Seat Disc (TA3169).................................................................... Teflon
discharges liquid. These valves are normally furnished with a 12”,
3⁄16” O.D. dip tube and incorporate a No. 54 drill size orifice.

An optional instruction plate with “Stop Filling When Liquid Appears’’


may be ordered for use with these valves.
1 1⁄8”
PRODU ⁄”
34

10
O

UL 1 1⁄8”
G

CT
RE

®
10

Y
NT

E
Y

AR A
WA R R

⁄ ” NPT
14
1⁄4 ”

NPT
1⁄4 ”

NPT
v = 12”
v = 12”
v = 12”

3165SF12.0 TA3169F12.0

3165SF12.0 3165CF12.0 TA3169F12.0

Ordering Information
Accessories
Part
Number Service Connection Actuation Dip Tube Length Warning Plate Kit
3165CF* *
Knurled
3165CF12.0 LP-Gas Only
¼” M. NPT 2550-40P
3165SF12.0 Slotted 12”
TA3169F12.0 LP-Gas & NH3 Tee Handle

J18
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Spanner Wrench for ACME Connectors
3195-50

Application
This aluminum spanner wrench is especially designed for use with
21⁄4” and 31⁄4” ACME couplings, adapters and caps.

PRODU
3195-50

10
O
UL
G

CT
RE
®

S
10

Y
NT
E
Y

AR A
WA R R

Ordering Information
Part Number For Use With ACME Connector Size
3195-50 2¼” & 3¼”

Pressure Gauges

Application
Especially designed in a variety of sizes and construction for the LP-
Gas and anhydrous ammonia industry.

All RegO® pressure gauges have a 1⁄4” M. NPT connection unless J


otherwise noted.

PRODU

10
O
G

CT

UL
RE

®
10

Y
NT

E
Y

AR A
WA R R

Ordering Information
Part Number Service Case Material Maximum Pressure Case Size Increment Divisions
2434A-2* 35” w.c. and 1” w.c. and
2½”
2434-2** Steel 20 oz. (Dual) 1 oz.
3226A-3
30 PSIG ½ PSI
2411
Brass
5575
60 PSIG 2” 1 PSI
5547 Steel
LP-Gas
5576 Brass
Only
1286 Steel 100 PSIG 2 PSI
1178 2½”
948 Brass
612** 300 PSIG 2” 5 PSI
948B Steel
1183 Brass 500 PSIG 20 PSI
A8060 60 PSIG
NH3 and 2½”
A8150 Steel 150 PSIG 5 lb.
LP-Gas
A8400 400 PSIG
* 1/4” Hose Connection
** 1/8” M. NPT Connection

J19
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Needle Valves 1224, 1316 and 1318
Application
These valves are high quality, “true’’ throttling valves. Unlike most
socalled needle valves, both the body seat and stem are tapered to
provide fine, precise control over a wide range of adjustment without UL
stem galling. ®

The 1224 may be used as a small, inexpensive shut-off valve between


a pressure gauge and bulk storage container to allow for convenient
gauge replacement.

The 1316 and 1318 provide taper pipe thread by left hand hose
connection threads and are useful in a wide range of torch and fuel
burner applications where an accurate throttling action is required.

1224
PRODU

10
O C
G

CT

B
RE

A
S
10

Y
NT

E
Y

AR A
WA R R

Ordering Information D

Part A. Inlet B. Outlet C. D.


Number Connection Connection Height Length
1224WA ¼” M. NPT ¼” M. NPT
1314WA ⅛” M. NPT 19/16” 1¾”
/ ” - 18 L.H.
9 16
1316WA ¼” M. NPT

Household Gas Detector/Alarm 100-HGD


J
Application
The 100-HGD gas fume detection/alarm unit gives advance warning
of gas leaks well below the hazard level (1⁄4th the lowest explosive
level). It provides the homeowner more time to take action to protect
the family and remedy the problem.
PRODU

10
O

Features
G

CT
RE

S
100-HGD
10

Y
• Available in attractive high impact plastic housing.

NT
E
Y

AR A
WA R R

• Fume detection systems are reliable and a snap to install.

• Early warning: a high pitched audio alarm and red light visual
alarm is activated when propane fumes reach a level of only ¼ the
danger level.

• Built in power filtering system for protection against power


fluctuations. Maximum Level
Approximately 2 Feet

• Every semiconductor sensor unit is properly acclimatized and


From Floor For Propane
Maximum Level
custom calibrated to the individual circuitry in which it is installed Approximately 2 Feet

to ensure maximum sensitivity, reliability and accuracy. From Floor For Propane

• Solid state electronic circuitry.

• Supplied with CSA approved converter for use with standard 110 Typical
volt outlets. Installation
Converter PlugsPlugs
Converter Into
Unit Specifications Standardinto
110Standard
Volt Outlet
110 Volt Outlet

Height . . . . . . . . . . . . 3¾”
Width . . . . . . . . . . . . . 5¾”
Depth . . . . . . . . . . . . . 1⅜”
UL
®

Ordering Information
Part Number Description
100-HGD Household Propane Gas Alarm

J20
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
Cross Reference by Part Number
12802................................................................................................ J17 7193D-10.......................................................................................... J15
100-HGD........................................................................................... J20 7193K-10B........................................................................................ J16
1178.................................................................................................. J19 7193L-10A......................................................................................... J16
1183.................................................................................................. J19 7193T-10........................................................................................... J15
1286.................................................................................................. J19 7193U-10.......................................................................................... J15
1316WA............................................................................................. J20 7194-1............................................................................................... J13
2070CO............................................................................................... J6 7194H-3K.......................................................................................... J13
2071-L25.7.......................................................................................... J6 7194HD............................................................................................. J13
2071-L39.7.......................................................................................... J6 7194M-3K......................................................................................... J13
A2141A10.............................................................................................. J7 7194MD............................................................................................ J13
A2141A16.............................................................................................. J7 7605A-BT.......................................................................................... J12
A2141A6................................................................................................ J7 7605AP-15........................................................................................ J12
A2141A6L.............................................................................................. J7 7605AP-16........................................................................................ J12
A2141A8................................................................................................ J7 7605APN-8A..................................................................................... J12
A2141A8L.............................................................................................. J7 7605PN-50........................................................................................ J12
2411.................................................................................................. J19 7781AFPN-1..................................................................................... J12
2434-2............................................................................................... J19 A7794.................................................................................................. J14
2434A-2............................................................................................ J19 A7796.................................................................................................. J14
A2805C............................................................................................... J17 7901TB............................................................................................. J13
3165C............................................................................................... J18 A8060.................................................................................................. J19
3165CF.............................................................................................. J18 A8150.................................................................................................. J19
3165CF12.0...................................................................................... J18 A8400.................................................................................................. J19
3165S................................................................................................ J18 A9091-18L............................................................................................. J4
3165SF12.0...................................................................................... J18 A9091-18LX.......................................................................................... J4
TA3169F12.0.......................................................................................... J18 A9091-18N............................................................................................ J4
3195-50............................................................................................. J19 AA9091RM24.......................................................................................... J5
3226A-3............................................................................................ J19 9091RM24.......................................................................................... J5
5547.................................................................................................. J19 AA9092RM36........................................................................................... J5
5575.................................................................................................. J19 9092RM36.......................................................................................... J5
5576.................................................................................................. J19 AA9093RSM48......................................................................................... J5
6010...................................................................................................J11 9093RSM48........................................................................................ J5
AA6010....................................................................................................J11 AA9093TSM48......................................................................................... J5
6016.................................................................................................. J10 9093TSM48........................................................................................ J5
AA6016................................................................................................... J10 AA9094RSM60......................................................................................... J5
6016-60D.......................................................................................... J12 9094RSM60........................................................................................ J5
6024.................................................................................................. J10
AA6024................................................................................................... J10
AA9094TSM60......................................................................................... J5
9094TSM60........................................................................................ J5
J
612.................................................................................................... J19 AA9095RSM72......................................................................................... J5
7177.................................................................................................. J13 9095RSM72........................................................................................ J5
7188.................................................................................................. J13 AA9095TSM72......................................................................................... J5
7188-21............................................................................................. J13 9095TSM72........................................................................................ J5
7188HS............................................................................................. J13 948.................................................................................................... J19
7188MS............................................................................................. J13 948B.................................................................................................. J19
7193-4............................................................................................... J13 TSS3169................................................................................................ J18
7193D-10.......................................................................................... J13

J21
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
J

J22
Engineered Controls International, Inc.100 RegO Dr. P.O. Box 247 Elon, NC 27244 USA [Link] Phone (336) 449-7707 Fax (336) 449-6594
[Link]

Catalog L-500