Electrical Schematic for Health Station

This document provides general notes and specifications for an electrical installation for a proposed building project. It specifies that all electrical work must comply with relevant codes and standards. Materials must be new and approved. Wiring will be done through PVC conduits not smaller than 20mm in diameter. There will be a single electrical service drop from the nearest utility pole to the building. Wires used shall be no smaller than 3.5mm copper with 600-volt insulation. The service will be single-phase 220V AC.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views1 page

Electrical Schematic for Health Station

This document provides general notes and specifications for an electrical installation for a proposed building project. It specifies that all electrical work must comply with relevant codes and standards. Materials must be new and approved. Wiring will be done through PVC conduits not smaller than 20mm in diameter. There will be a single electrical service drop from the nearest utility pole to the building. Wires used shall be no smaller than 3.5mm copper with 600-volt insulation. The service will be single-phase 220V AC.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GENERAL NOTES:

1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE, RULES AND REGULATIONS OF THE (NAME OF ELECTRICAL COMPANY/SUPPLIER) AND THE LOCAL
GOVERNMENT.\
2. ALL ELECTRICAL MATERIAL AND EQUIPEMENTSTO BE USED IN THIS PROJECT SHALL BE BRAND NEW AND APPROVED
QUALITY AND BRAND.
3. THE ELECTRICAL WIRINGS SHALL BE THROUGH PVC CONDUIT PIPES NOT SMALLER THAN 20mm DIA., SCHEDULE 40.
4. THERE SHALL BE ONLY ONE SERVICE DROP FROM THE NEAREST ELECTRICAL COMPANY POLE TO THE PROPOSED
BUILDING.
5. WIRES TO BE USED SHALL BE NOTV SMALLER THAN 3.5mm TW., WITH 600 VOLTS INSULATION
6. THE TYPE OF SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE, 220V, A.C.

USE 2 - 14mm sq.


THHN/THWN STRANDED USE 2 - 14mm sq. TO 230V AC, 1Ø.
Cu. WIRE IN 25MM Ø RSC. THHN/THWN STRANDED 60Hz ELECTRICAL
Cu. WIRE IN 25MM Ø RSC. SERVICE POWER
PANEL BOARD
MANUAL POWER SWITCH
(MTS)
TO 230V AC, 1Ø.
TO AVAILABLE BACKUP
60Hz ELECTRICAL
POWER SUPPLY (GEN SET)
SERVICE POWER

LO 1 2 CO
60AT 60AT

ACU 3 4 ACU

SPARE 5 6 SPARE
USE 2 - 14mm sq.
THHN/THWN STRANDED
Cu. WIRE IN 25MM Ø RSC.

PB

SCHEMATIC DIAGRAM
NOT TO SCALE

PROJECT TITLE: PREPARED BY: CHECKED BY: CONCURRED BY: APPROVED BY: SHEET CONTENT: SHEET NO.
Republci of the Philippines · SCHEMATIC DIAGRAM
Province of Biliran
Municipality of Maripipi
CONSTRUCTION OF BRGY.
HEALTH STATION
JOENYL FERNAND C. CAINGCOY ENGR. LOU STANLEY I. PULVERA MARY GRACE R. LLEVER, MD. HON. JOSEPH C. CAINGCOY, RPsy. Ph.D.
· ELECTRICAL SPECS E
OFFICE OF THE MUNICIPAL ENGINEER
LOCATION: BRGY. VIGA MARIPIPI, BILIRAN DRAFTSMAN DESIGNATE MUNICIPAL ENGINEER MHO MUNICIPAL MAYOR 2