TIG Brush ®
TBE-550
STAINLESS STEEL WELD CLEANING SYSTEM QUICKSTART GUIDE
KIT CONTENTS SAFETY
12 x Brushes Shrouds
& adapters (Up to 3 types)
• INSPECT UNIT FOR DAMAGE
BEFORE EVERY USE.
• EYE PROTECTION AND
GLOVES MUST BE WORN.
• USE ONLY IN A WELL
Red Black Cable Fluids x 2 Power Wand VENTILATED AREA.
TIG Brush Unit Cable and Clamp Cord • KEEP UNIT DRY.
• USE ONLY SINGLE PHASE
AC POWER FROM 110V/240V.
ASSEMBLY • REFER TO FLUID SAFETY
INFORMATION IN SAFETY
• Attach plug on red cable to DATA SHEET.
red connector of TIG Brush
Unit
• Screw wand into handle
• Place shroud on brush and
screw into wand 110V AC 240V AC
• Attach plug on black cable Single phase Single phase
to black connector of TIG
Brush Unit Wand
• Attach clamp to work piece
• Set POWER control to Work piece Shroud
Standby
• Attach power cord to mains
outlet and TIG Brush Unit Brush
INSULATING SHROUD
MUST BE USED!
OPERATION CONSUMABLES
1 Use only genuine
Ensitech consumables:
• Ensure On/Off switch is ON brushes, shrouds and
• Select mode of operation fluids.
• Operate Power Control to select
NARROW or WIDE BRUSH [Link]
STANDBY
POWER
NARROW BRUSH
WIDE BRUSH
RINSE
CLEAN
MODE
RESTORE
SURFACE
MARKING
2
GUIDE- 2015-03-03
HINT 3
G
• Pour recommended cleaning fluid into
GUIDE - DEC-10
suitable container Don’t press hard.
TBE-550 QUICKSTART
• Dip brush For greater • Rinse brush after use to remove
• Brush weld area (see hint) efficiency and solution
QUICKSTART
• Keep brush wet: dry brush is less effective and speed, use tip of • Remove brush (CAUTION: HOT) and
wears out more quickly brush only. rinse thread on brush and wand
BRUSH
• Water rinse work piece to help lower surface
TBE-250
• Retain shroud when disposing of
heat and spray with appropriate neutralising used brush
TIG
fluid, then re-rinse
[Link]