SL1000 SOFTWARE RELEASE NOTES

GENIE BRANDED MACHINE

Document P/N – 218504


Revision - E
Page 1 of 4
TABLE OF CONTENTS

PURPOSE ............................................................................................................................................................................... 3
SCOPE .................................................................................................................................................................................... 3
DEFINITIONS ....................................................................................................................................................................... 3

Document P/N – 218504


Revision - E
Page 2 of 4
PURPOSE
This document depicts the software release notes for the SL1000 Control systems for the models listed in the
scope.

SCOPE
This document applies to the following machine models: GR-12, GR-15, GR-20, GRC-12, QS-12, QS-15, QS-
20, GS-XX30, GS-XX32, GS-XX46, GS-2646AV, GS-4047, GS-XX69DC, and GS-XX69BE.

DEFINITIONS
1. ECM – an acronym for Electronic Control Module.
2. GCON – an acronym for Ground Controller. This is the ECM located at the ground controls.
3. PCON – an acronym for Platform Controller. This is the ECM located at the platform controls.

Document P/N – 218504


Revision - E
Page 3 of 4
Software Release Date Release Notes
Revision
 Non-production release
th
137641 Rev A April 11 , 2011  Machine Application Firmware and Bootloader has 100K baud
rate for CAN communication
 Firmware Release to support GR/GRC/QS, GS1530, GS1930,
st GS1532, GS1932
137641 Rev B June 1 , 2011
 Machine Application Firmware and Bootloader has 250K baud
rate for CAN communication
 PCON Alarm disabled for motion alarm option
th  Allows down delay to be enabled/disabled independently of
137641 Rev C October 18 , 2011
the platform overload option
 Improvements to automotive horn fault detection
th  Firmware support added for GS2032, GS2046, GS2632,
137641 Rev D December 20 , 2011
GS2646, GS3232, GS3246
th  Improvements to down delay and platform descent
137641 Rev E February 28 , 2012
functionality
th  Improvements to platform overload auto-detect functionality
137641 Rev G May 14 , 2012
 Improvements to reduce CPU usage
th  Firmware support added for GS2646AV
137641 Rev H June 12 , 2012
 Firmware support added for Manitou service tool branding
rd  Improvements to GS3232 outrigger calibration and end of
137641 Rev J July 3 , 2012
stroke detection
th
137641 Rev K July 24 , 2012  Improvements to platform overload auto-detection
th  Improvements to 4047 platform overload system.
137641 Rev M August 28 , 2012
 Additional platform up fault detection
th  Improvements to detection of F035 in cold weather
137641 Rev N November 6 2012
 Alteration of Footswitch faults from level 1 to level 0
th
137641 Rev P March 12 2013  Improvements to the detection of F009 for the 3232 and 4047
th
137641 Rev T August 20 , 2013  Improvements to C021 detection and load sense calibration
 Combining software for both 69DC and GR/Slab
 Real time Diagnostic Page added
th  Improvements to Battery level detection and recharge
137641 Rev W October 4 2013
 System Start up time of Smartlink reduced
 Ability to clear all faults added to Service tool
 Automatic detection of date/time on the Service Tool
 Improvements to Battery Charge Level Detection on 69DC
th  Improvements to machine tilt detection for 69DC
137641 Rev Y December 16 2013
 Improvements to F051 (Accumulator Switch Short to Bat+)
fault detection on 69DC
 Implemented functionality for the 2669, 3369 and 4069 Bi-
th Energy Models
137641 Rev AA March 15 , 2014
 Updated the default pump speeds in accordance to the new
pumps installed on all large slabs.
th  Service tool connectivity improvement
137641 Rev AB August 11 , 2014
 69DC load sense improvement
th
137641 Rev AC March 16 , 2015  69DC tilt sense improvement

Document P/N – 218504