0% found this document useful (0 votes)
58 views6 pages

DynoWare Software for Data Acquisition

DynoWare is software for data acquisition and evaluation, particularly suitable for force measurements. It allows for simple operation, configuration of instruments, useful signal evaluation functions, simultaneous recording of up to 28 channels, and real-time visualization of measured curves. DynoWare supports various data acquisition cards and USB systems for measuring physical values from Kistler and other manufacturers' instruments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views6 pages

DynoWare Software for Data Acquisition

DynoWare is software for data acquisition and evaluation, particularly suitable for force measurements. It allows for simple operation, configuration of instruments, useful signal evaluation functions, simultaneous recording of up to 28 channels, and real-time visualization of measured curves. DynoWare supports various data acquisition cards and USB systems for measuring physical values from Kistler and other manufacturers' instruments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Electronics & Software

DynoWare Type 2825A...

Software for Data Acquisition and Evaluation

Kistler DynoWare is a universal and easy to use software, which


is particularly suitable for force measurements with dynamo-
meters or single and multi-component force sensors.

• Simple operation
• Configuration and control of Kistler measuring instruments
via USB, RS-232C or IEEE-488
• Useful signal evaluation and calculation functions
• Simultaneous recording of up to 28 measuring channels
• Realtime visualization of measured curves
• The software is ideal for the acquisition and evaluation of
physical measurands

Description
For signal analysis, DynoWare offers the technician realtime
visualization of the measured curves together with useful
calculation and graphics functions. Apart from simple con- Technical Data
figuration of the most important measuring instruments, this
software supports individual documentation of the measure- Data Acquisition Cards Supported
ment, along with storage of configuration data and measured Type 2855A4, PCIM-DAS 1602/16
data. The signal evaluation also enables compensation of PC bus: PCI
undesirable signal drift due, for example, to undue influence Number of measuring channels: 8, analog, differential
of temperature. Resolution: 16 Bit
Measuring range: ±1,25 V; ±2,5 V; ±5 V; ±10 V
DynoWare supports several A/D cards (PCI/PCMCIA) as well Sampling rate: 1 measuring channel active: 100 kS/s
as USB 2.0 of DAQ-System Type 5697A. 8 measuring channels active: 12,5 kS/s

Application Type 2855A5, PC-CARD-DAS 16/161)


DynoWare is the data acquisition software of choice for cut- PC bus: PCMCIA, PC-CARD
ting force measurement. It supports both stationary and rotary Number of measuring channels: 8, analog, differential
measuring systems from Kistler. Resolution: 16 Bit
However, DynoWare can also be used for any reaction force Measuring range: ±1,25 V; ±2,5 V; ±5 V; ±10 V
measurements or crash measurements with Kistler multicom- Sampling rate: 1 measuring channel active: 100 kS/s
ponent dynamometers. At the same time, the measured data 8 measuring channels active: 12,5 kS/s
from signal amplifiers of other manufacturers can also be mea-
sured and evaluated. Type 5697A: USB DAQ-System
2825A_000-371e-03.11

Connection: UBS 2.0


Number of measuring channels: 282), analog, single-ended
Resolution: 16 Bit
Measuring range: ±0,1 V, ±0,2 V, ±0,5 V, ±1 V, ±2 V, ±5 V, ±10 V
Sampling rate: 1 Channel active: 1 MS/s
8 Channels active: 125 kS/s
16 Channels active: 62,5 kS/s
1)
Not supported on Windows Vista and Windows 7.
2)
DynoWare Type 2825A as well as Update Type 2825E allow to control
one charge amplifier only. DAQ-System Type 5697 is capable to acquire 28
channels maximum.
Page 1/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
DynoWare – Software for Data Acquisition and Evaluation, Type 2825A...

Measuring Instrument Control and Configuration via Communica- Tools


tion Interfaces Voltmeter function
RS-232C Oscilloscope function
5011Bx2, 5015A..., 5017..., 5018A..., 5019..., 5070A…, 5080A...,
5223..., 5237..., 5238... Documentation of the Measurement
IEEE-488 Each measurement can be individually documented.
5011Bx1, 5015Ax1xx, 5070Axxxx1 Storage of measurement and configuration data with or without
USB 2.0 remarks
5018A..., 5080A... Export of measured data and ASCII format (.txt) or (.csv) for Excel,
DIAdem, LabVIEW, Matlab, etc.
Triggering
Analog, digital and by Keyboard Printer
Printing of test records and configuration data is supported by
Digital Signal Evaluation Windows
Within a measuring window
Averaging
Minimum and maximum values Example of a Test Record
Integral
Determining the signal frequency
Signal smoothing/filtering
Moving mean value
Moving median value
Filters: High pass, low pass, band pass and band stop
Compensation of signal drift

Graphics Functions
Measured data represented on one or more graphs
Display as y(t) and y(x) graphs
Display of numeric values
Cursor function
Zoom function

Calculation Functions
Multi-component force-moment calculation
Calculation of radial and tangential forces with rotating cutting force
dynamometer Type 9123…/24…
Mathematical functions
2825A_000-371e-03.11

Page 2/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
DynoWare – Software for Data Acquisition and Evaluation, Type 2825A...

Cable Concept for DynoWare Type 2825A… with A/D Cards Type 2855A4 and Type 2855A5

Signal Conditioner Measuring Signal Connecting Cable A/D Acquisition Card

Type Type 1500B15


5017… D-Sub pos. 15 pole Type 1500B15 D-Sub neg. 37 pole
5019…
5070…
5080...1)
5223… Digital L
Type 2855A4
Trigger H
5237… Digital L
PCIM-DAS1602/16 (PCI-Bus)
Output H
5238... 2m

D-Sub pos.
37 pole
Type Type 1500A67
5011… 8x BNC pos. Type 1500A67 D-Sub neg. 37 pole
5015…
5017…
5018...
5019…
5223…
5237…
5238...
other products
2m

Only for signals from the 6-component summing calculator

Type Type 1500A7 Type 1500B69


5017Bxxx1 D-Sub pos. 15 pole Type 1500B15 D-Sub neg. 37 pole D-Sub pos. 37 pole MERITEC 50 pole
5070Ax2xxx
5080Axx8xxxx2)

Digital L
Trigger H
Digital L 1m
Output H
2m

Type 2855A53)
2825A_000-371e-03.11

PC-CARD-DAS16/16 (PC-CARD-Bus)

50 pole

1)
Cable Type 1500B15 is used when output signals Fx1+2, Fx3+4, Fy1+4, Fy2+3, Fz1, Fz2, Fz3, Fz4 have to be acquired.
2)
Cable Type 1500A7 is used when summed signals Fx, Fy, Fz, Mx, My, Mz have to be acquired.
3)
Windows Vista/Windos 7 does not support PC card DAS 16/16

Page 3/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
DynoWare – Software for Data Acquisition and Evaluation, Type 2825A...

Cable Concept for DynoWare Type 2825A… with DAQ-System Typ 5697A

Signal Conditioner Measuring Signal Connecting Cable A/D Acquisition Card

Type Type 1700A111A2 Type 5697A


5017…
5019… D-Sub pos. 15 pole D-Sub neg. 15 pole

5070…
5080...3)
5223…
5237…
5238...

Type Type 1700A113A2


5011…
5015… 8x BNC pos. D-Sub neg. 15 pole
D-Sub pos. 15 pole
5017…
5018...
5019…
5223…
5237…
5238...
other products

3)
Cable Type 1700A111A2 can be used in addition with DAQ-System Type 5697A, regardless of summed or output signals being acquired.
2825A_000-371e-03.11

Page 4/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
DynoWare – Software for Data Acquisition and Evaluation, Type 2825A...

Interface Cables

Signal Conditioner RS-232C Interface Cable (Null Modem)

Type Type 1475A3


D-Sub pos. 25 pole Type 1475A3 D-Sub neg. 9 pole
5011Bx2
5017…
5019…
5223…

3m

Type D-Sub pos. 9 pole Type 1200A27 D-Sub neg. 9 pole


5015…
5018...
5070…
5080...
5237… 5m
5238...

Typical Measuring Chain with DAQ-System Type 5697A1

Dynamometer Connecting cable, Charge Amplifier Connecting cable DAQ-System


Notebook
high resistant
(customer)
Type 9129AA Type 1677A5 Type 5070A Type 1700A111A2 Type 5697A1 with DynoWare
Type 1200A27
2825A_000-371e-03.11

Page 5/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
DynoWare – Software for Data Acquisition and Evaluation, Type 2825A...

Requirements for the PC Ordering Key Type


• Operating System: Windows® NT4.0 (SP4), 2000, XP, Vista, Scope of Delivery Including Accessories
Windows® 7 (32-bit/64-bit versions)
• Pentium PC 500 MHz or higher DynoWare Complete Version 2825A-02-1
• Hard disc: 100 MB free space for data storage and software • Runtime license key for parallel interface
installation • DynoWare software on CD-ROM
• Memory: at least 512 MB RAM • Instruction manual
• Super VGA monitor, screen resolution set to at least 800x600
• Vacant port (PCI or PC-CARD) for data acquisition board DynoWare Complete Version 2825A-02-2
Type 2855A4/2855A5 • Runtime license key for USB interface (HASP)
• USB 2.0 port for DAQ-System Type 5697A • DynoWare software on CD-ROM
• USB port for USB/RS-232C converter (Type 2867) • Instruction manual
• Parallel interface Centronics (LPT1) or USB for license key
• CD-ROM drive DynoWare Update Version 2825E-02-0
• A color printer is recommended for creating hard copies of • DynoWare software on CD-ROM
graphs • Instruction manual
• Acrobat® Reader® for reading the PDF Instruction Manual
DynoWare Demo Version 2825D-02-0
Optional Accessories Type • DynoWare software on CD-ROM
• Data acquisition card 2855A4, PCIM-DAS 1602/16
• Data acquisition card 2855A5, PC-CARD-DAS 16/16 DAQ-System for DynoWare 5697A1
• DAQ system, USB 5697A... Complete version
• Connecting cable 1500B15 • HASP license key
• Connecting cable 1500A67 • DynoWare software on CD-ROM,
• Connecting cable 1700A111A2 Type 2825A
• Connecting cable 1500B69 • USB 2.0 DAQ-box
• Connecting cable 1700A113A2 • USB cable, length 1,8 m
• Interface cable 1200A27 • Universal AC/DC adapter 100 ... 240 V
• Interface cable 1475A3 • Instruction manual
• USB/RS-232C converter 2867
DAQ-System for DynoWare 5697A2
Update version
• DynoWare software on CD-ROM,
Type 2825E
• USB 2.0 DAQ-box
• USB cable, length 1,8 m
• Universal AC/DC adapter 100 ... 240 V
• Instruction manual
2825A_000-371e-03.11

Windows® is a registered trade mark of Microsoft Corporation.


Adobe® Reader® is a registered trade mark of Adobe.
Page 6/6
This information corresponds to the current state of knowledge. Kistler reserves ©1997 ... 2011, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@[Link], [Link]
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.

You might also like