The Vacon 5X is a small and robust range of AC drives designed for harsh industrial environments. It has power ratings from 0.37 kW to 7.5 kW for 1-phase 220V and 3-phase 220V/400V applications. The drive features a simple interface with 14 basic parameters and is easy to install, program, and integrate into control systems via Modbus RTU.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views4 pages

BC00357A

The Vacon 5X is a small and robust range of AC drives designed for harsh industrial environments. It has power ratings from 0.37 kW to 7.5 kW for 1-phase 220V and 3-phase 220V/400V applications. The drive features a simple interface with 14 basic parameters and is easy to install, program, and integrate into control systems via Modbus RTU.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

vacon 5x

small and robust ac drive


the simple drive for harsh environments

The Vacon 5X is a small and robust range of AC drives designed for the harsh environments
found in most process industries and on building sites. The powers available are from
0.37 kW to 7.5 kW (220 V, single-phase, 220 V and 400 V three-phase). The Vacon 5X range
is suited for all types of applications, typically industrial conveyors, fans and pumps.

The rugged IP55 enclosure allows installation directly on the Features


wall or other suitable place without further protection in most
• Small footprint
environments. The Vacon 5X range offers alternatives with or
without an integrated RFI filter and with or without an inte- • Integrated main switch available
grated main switch, providing solutions for the most differing • Designed for a harsh and wet environment
needs. • Simple in construction
• Easy to use due to advanced features
The Vacon 5X is easy to install and commission. There are only
a dozen basic parameters to adjust (related to ramp times and • Fast setup: 14 basic parameters handle most applications
motor data), and the I/O interface is simple. The simple key- • Display of motor current and motor rpm
pad and programming matches that of the Vacon 50X and 500X
• Modbus RTU included
ranges, creating a compatible family of AC drives for tough en-
vironments. The Modbus RTU is included as standard, making • Control location can be chosen: I/O, keypad or fieldbus
integration into fieldbus control systems easy. • Integrated brake chopper for sizes 2 and 3
• IH sizing: 50% overload for 1 minute
Industrial segments
• 75% overload for 2 seconds
• Food processing
• Optional memory stick programming for easy copying of
• Bottling lines
data between drives
• Pumping
• Chemical • Programmable via a PDA or smart phone
• Wastewater
• HVAC
sizes and ratings

Motor nominal Drive nominal Order type code Main switch EMC4 Frame Measurements Weight
power (kW) current (A) (optional) (optional) (mm) (kg)
Add Add WxHxD

1 x 220 VAC

0.37 2.3 VACON0005-1L-0002-2-X-1 +CILS +EMC4 F1 78x172x123 1.1

0.75 4.3 VACON0005-1L-0004-2-X-1 +CILS +EMC4 F1 78x172x123 1.1

1.5 7 VACON0005-1L-0007-2-X-1 +CILS +EMC4 F1 78x172x123 1.1

1.5 7 VACON0005-1L-0007-2-X-2 +CILS +EMC4 F2 104x220x150 2.6

2.2 10.5 VACON0005-1L-0011-2-X-2 +CILS +EMC4 F2 104x220x150 2.6

3 x 200 – 240 VAC

0.37 2.3 VACON0005-3L-0002-2-X-1 +CILS +EMC4 * F1 78x172x123 1.1

0.75 4.3 VACON0005-3L-0004-2-X-1 +CILS +EMC4 * F1 78x172x123 1.1

1.5 7 VACON0005-3L-0007-2-X-1 +CILS +EMC4 * F1 78x172x123 1.1

1.5 7 VACON0005 3L-0007-2-X-2 +CILS +EMC4 F2 104x220x150 2.6

2.2 10.5 VACON0005-3L-0011-2-X-2 +CILS +EMC4 F2 104x220x150 2.6

4 14 VACON0005-3L-0014-2-X-3 +CILS +EMC4 F3 140x250x160 4

3 x 380 – 480 VAC

0.75 2.2 VACON0005-3L-0002-4-X-1 +CILS +EMC4 F1 78x172x123 1.1

1.5 4.1 VACON0005-3L-0004-4-X-1 +CILS +EMC4 F1 78x172x123 1.1

1.5 4.1 VACON0005-3L-0004-4-X-2 +CILS +EMC4 F2 104x220x150 2.6

2.2 5.8 VACON0005-3L-0006-4-X-2 +CILS +EMC4 F2 104x220x150 2.6

4 9.5 VACON0005-3L-0010-4-X-2 +CILS +EMC4 F2 104x220x150 2.6

5.5 14 VACON0005-3L-0014-4-X-3 +CILS +EMC4 F3 140x250x160 4

7.5 18 VACON0005-3L-0018-4-X-3 +CILS +EMC4 F3 140x250x160 4

* = Only +EMC4 version available

Options
+CILS = Main switch version available
+EMC4 = Version for the category C4 available
(Providing no EMC protection: requires centralized action, for industrial environments)

i/o connections
• 2 analog inputs: configurable 0…10 V, 0/4…20 mA (speed reference and actual value signal)
• 3 digital inputs (0/24 V): one of which is one of the analog inputs as well
• 1 analog/digital output 0…10 V or 0/4…20 mA analog; 24 V max as digital output
• 1 NO relay
• 10 V reference voltage out
• 24 V I/O supply voltage

External brake resistors


AC drive Minimum brake resistance
200 V single- and three-phase models 47 ohms

400 V models, frame size 2 100 ohms

400 V models, frame size 3 22 ohms


technical data

Mains Input voltage Uin 208…240 V; 380…480 V; –10%…+10%


connection Input frequency 48…62 Hz
Motor Output voltage 0…Uin
connection Continuous output current Ambient temperature max. +40°C, overload 1.5 x IH (1 min./10 min.)
Output frequency 0…500 Hz
Frequency resolution 0.1 Hz
Control Control method U/f Control
characteristics Switching frequency 4…32 kHz effective
Frequency reference Analog (0…10 V, 0…20 mA, 4…20 mA)
Analogue input Digital (keypad)
Panel reference PI control (integral)
Modbus RTU
Field weakening point 25…500 Hz
Acceleration time 0…600 sec
Deceleration time 0…600 sec
Braking torque DC brake: 30% x T N (without brake option)
Ambient conditions Ambient operating temperature –10°C (no frost)…+40°C: IH
Storage temperature –40°C…+60°C
Relative humidity 0 to 95% RH, non-condensing, non-corrosive, no dripping water
Altitude 100% load capacity (no derating) up to 1,000 m
1% derating for each 100 m above 1,000 m
max. 2,000 m with UL, max. 4,000 m without UL
Enclosure class IP55
EMC Immunity Fulfils EN61800-3, first and second environment
Emissions Fulfils EN61800-3, first and second environment
Safety EN 61800-5-1 (2003), EN 60204-1 (2006),
CE, UL, cUL, C-tick; (see unit nameplate for more detailed approvals)
Control Analogue input voltage 0…+10 V, Ri = 72 kΩ
connections Resolution 0.025%, linearity < 1% deviation
Analogue input current 0(4)…20 mA, Ri = 500 Ω
Digital inputs (3) Positive logic; 18…30 VDC
Logic 0: 0…2 V, Logic 1: 8…30 V
Auxiliary voltage +24 V, ±5%, max. voltage ripple < 100 mV; max. 100 mA
Output reference voltage +10 V, +3%, max. load 10 mA
Analogue output Analog output: 0…10 V (20 mA max).
Resolution: 10 bits, linearity < 2% deviation
Digital outputs Digital output: 0 V / 24 V push-pull, 20 mA max
Relay outputs 1 NO relay output
Switching capacity: 30 VDC / 5 A, 250 VAC / 6 A,
Min. switching load: 5 V / 10 mA
Protections Overvoltage trip limit For 400 V 3-phase supply drives:
Undervoltage trip limit Overvoltage trip level: 835 V
Undervoltage trip level: 478 V (rising volts), 320 V (falling volts)

For 230 V supply drives:


Overvoltage trip level: 418 V
Undervoltage trip level: 239 V (rising volts), 160 V (falling volts)
Earth fault protection In case of earth fault in motor or motor cable, only the frequency
converter is protected
Mains supervision Trips if any of the input phases is missing
Motor phase supervision Trips if any of the output phases is missing
Overcurrent protection Yes
Unit overtemperature protection Yes
Motor overload protection Yes
Motor stall protection Yes
Motor underload protection Yes
Short-circuit protection of +24 V and Yes
+10 V reference voltages