0% found this document useful (0 votes)
369 views1 page

MID 036 - CID 0279 - FMI 04 Aftercooler Temperature Short To Ground

The document provides information about troubleshooting a Caterpillar 3516B marine engine. It describes a fault code related to the aftercooler temperature sensor being shorted to ground, including the conditions that generate the code and the system response. It provides instructions to perform a diagnostic test to check for open or short circuits in engine sensors.

Uploaded by

TASHKEEL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
369 views1 page

MID 036 - CID 0279 - FMI 04 Aftercooler Temperature Short To Ground

The document provides information about troubleshooting a Caterpillar 3516B marine engine. It describes a fault code related to the aftercooler temperature sensor being shorted to ground, including the conditions that generate the code and the system response. It provides instructions to perform a diagnostic test to check for open or short circuits in engine sensors.

Uploaded by

TASHKEEL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

3516B Marine Engine S2X00001-UP(SEBP3924 - 59) - Systems & Components Page 1 of 1

Shutdown SIS

Previous Screen

Product: MARINE ENGINE


Model: 3516B MARINE ENGINE S2X
Configuration: 3516B Marine Engine S2X00001-UP

Troubleshooting
3500B and 3500C Marine Propulsion Engines
Media Number -RENR5009-08 Publication Date -01/08/2010 Date Updated -26/10/2016

i01954877

MID 036 - CID 0279 - FMI 04 Aftercooler Temperature short


to ground
SMCS - 1063-038
MID 036 CID 0279 FMI 04

Conditions Which Generate This Code:

The Electronic Control Module (ECM) reads an output voltage that is 0.2 VDC or less for one second.
The ECM has been powered for three seconds. The CID-FMI 262-03 and/or the CID-FMI 262-04 are
not active.

System Response:

The CID-FMI is logged in memory. The ECM no longer optimizes engine operation according to
aftercooler temperature. The ECM flags aftercooler temperature as invalid data. The engine
monitoring system is disabled for aftercooler temperature.

Test Step 1. Perform the following diagnostic procedure: "Engine Sensor Open/Short Test"

Results:

• OK - STOP

• REPAIRED, OK - STOP