Technical support
For assistance with this product, refer to this document and any other
TruPortal™ Series documentation provided. If you still have questions, you may contact technical
support during normal business hours (Monday through Friday, excluding
T-200 Model Reader (en-US) holidays, between 8 a.m. and 8 p.m. Eastern Standard Time.)
See http://www.interlogix.com/customer-support.
U.S.
1-855-286-8889, option 2
Canada
1-855-286-8889, option 2
Latin America
1-561-998-6114
Web site: http://www.interlogix.com
© 25JUL13, United Technologies Corporation
Interlogix is part of UTC Climate, Controls & Security, a unit of United
Technologies Corporation. All rights reserved.
Interlogix
3211 Progress Drive, Lincolnton, NC 28092, USA
Description 6. Hook the top of the reader case to the top of the base
plate and press into place.
The T-200 card reader is a card serial number reader Figure 2. Aligning top cover, reader case, and base plate.
compatible with the following 13.56 mHz technologies:
Vicinity (ISO 15693) HID iCLASS® Serial Number
Infineon my-d® Serial Number
Philips I-Code Serial Number
Proximity (ISO14443) DESFire® Serial Number
MIFARE® Serial Number
Mounting the reader
1. Find a suitable mounting position on the door frame
or wall. 7. Install the supplied screw in the base of the reader.
2. Drill two vertical mounting holes 2.25” (57.2 mm) 8. Snap the cover on the top of the case.
apart on the mounting surface of the door frame or
wall. Connecting the cable
Figure 1. Dimensions 1. The readers are supplied with an 8-conductor cable
1.75 1.0
[44.5mm] [25.4mm]
pigtail with drain wire. Connect the pigtail to the host
panel. Use the Cable Connection Chart (below) to
correctly match the color of each wire.
Color Signal
4.20
Black Ground
[106.7mm] Blue Beeper
Brown Red LED Control
Green Data 0
Orange Green LED Control
front view side view
Red 5 to 16 VDC
3. Drill one 1.00” (25.4 mm) diameter hole in wall for the White Data 1
pigtail wire connection.
Drain Shield Ground
4. Follow the Cable Connection Chart to connect the
reader to the field panel and external door 2. Use a DC power source between 5-16 VDC.
equipment. 3. Connect reader’s drain wire to the cable shield.
5. Mount the base plate to the wall using the supplied Connect shield wires at the field panel.
screws.
Testing the reader The voltage specification for this reader is 5-16
VDC, although 12 VDC or greater is recommended
1. Power up the reader. Verify the power-on self for better performance and cable run distances.
test LED/beep sequence:
The recommended cable gauge is 18-gauge to 22-
- green LED flashes; two short beeps
gauge. Check with the cable supplier to determine
- yellow LED flashes; three short beeps
the best choice for the application and installation
- red LED flashes
distance.
- yellow LED flashes
2. Verify the yellow LED is on continuously FCC compliance
indicating the reader is ready.
The FCC requires the following statement: This
3. Present a badge that has been properly reader uses radio frequency energy, has been
enrolled in the system. Verify the green LED tested, and complies with the limits of FCC testing.
lights and a short beep is heard. Changes, modifications, or disregard of proper
installation and instructions not expressly approved
Removing the cover by United Technologies are strictly prohibited by
the FCC and could void the user’s authority to
To remove the cover, squeeze the sides of the top
operate the equipment.
cover and pull to release the cover.
Specifications Ordering information
Colors Black, Charcoal, Gray Product Part numbers
Power supply Linear DC recommended T-200 TP-RDR-200a
(3 covers, 18" / 45.7 cm pigtail wire)
Power usage 50 mA @ 12 VDC
T-200 TP-RDR-200b
Voltage range 5 - 16 VDC
(3 covers, 84" / 214 cm pigtail wire)
Temperature -31°F to 149°F
rangea (-35°C to 65°C) Note: Each part number includes all three colors of the
cover plates (black, charcoal, gray).
Cable distance to
panelb Cable Distance
Max. @ 12 VDC AWG
200 ft. (60.96 m) 22
300 ft. (91.44 m) 20
500 ft. (152.4 m) 18
Read Rangec - Mifare:
(Distances may up to 1.0" (2.54 cm)
vary depending on Ultralight cards not supported
environment.) - Vicinity: up to 3.5" (8.89 cm)
Wiegand output - Mifare 4002 (40-bit)
- Vicinity 5502 (55-bit)
Regulatory UL 294, CE, and FCC (part 15) © 25JUL13, United Technologies Corporation
approvals and
standards Interlogix is part of UTC Climate, Controls & Security, a
ISO Standards Mifare ISO 14443A unit of United Technologies Corporation. All rights
Vicinity ISO 15693 reserved.
UL evaluation for UL Listed Installations: The TruPortal product name and logo are trademarks of
a. -25°F to 125°F (32°C to 52°C) United Technologies. Other trade names used in this
b. 500 ft. (152.4 m) max. 22 AWG @ 12 VDC document may be trademarks or registered trademarks
200 ft. (60.96 m) max. 22 AWG @ 5 VDC of the manufacturers or vendors of the respective
c. Vicinity: up to 3.0" (7.62 cm) products.
Document number: 460950002D - July 2013