0% found this document useful (0 votes)
90 views4 pages

Top Pette

The document summarizes the features of TopPette mechanical pipettes. It describes that they are lightweight, have an ergonomic design, and digital displays. They cover a volume range from 0.1 μL to 10mL. Each pipette is individually calibrated and supplied with a certificate. The document also lists specifications for accuracy and precision at different volume increments.

Uploaded by

txbcgzn8t2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views4 pages

Top Pette

The document summarizes the features of TopPette mechanical pipettes. It describes that they are lightweight, have an ergonomic design, and digital displays. They cover a volume range from 0.1 μL to 10mL. Each pipette is individually calibrated and supplied with a certificate. The document also lists specifications for accuracy and precision at different volume increments.

Uploaded by

txbcgzn8t2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TopPette Mechanical Pipettes

Features f。r TopPette

• Light weight, ergonomic, low force design


• Digital display clearly reads volume setting
• The pipettes cover volume range of 0.1 µL to 1Oml
• Easy to calibrate and maintain with tool supplied
• Design helps avoid 「epetitive st「ain injuries
• Calibrated in accordance with 1508655. Each pipette supplied
with individual test certificate
• The lower section can be autoclaved

Simply turn the plunger button for


volume selection

Finger support with


minimum user effort
Tip ejector allows
convenient one-handed
operation
a〈JZ、。哇’向


,。盼-
u

, Ejector collar and tip cone can


I e removed

Durable tip cone materials


Provide excellent chemical
resistance

03
Features f。r multi-channel T。pPette

• 8 and 12 channel pipettes are available for standard 96-well plate


• Dispensing head rotates for optimum pipetting convenience
• Individual piston and tip cone assemblies allow easy repair and maintenance

. • Compound mate「ial tip cone design allows visual seal verification


• Can be used with unive「日I style pipette tips

sg
...........,
12 channels 8 channels ggg

Pipette with switch

DRAGONLAB Pipettes can be stopped with an on/off switch


and cable. This can be used with coagulation analyze『E O「 any
other instruments that 「equire precise timing.
Plus Autoclavable Pipettes

EEEE ’’目
,,
..
EEEea
,-
a··Baa

TopPette/ MicroPette I MicroPette Plus Mechanical F-

liIttEItI
--I
Pipettes (Adjustable and Fixed Volume)

’’’
I’-
t-『’’
Maximum permissible systematic error

lf
Maximum permissible random error (Imprecision)

l
(Inaccuracy)


Increment Test Volume

l
’ tf
』』fFEFAt
%
”L %
”L


lt」
2.SµL 2.50% 0.0625 2.00% 0.05

t
ga
0.1-2.SµL [Link]µL 3.00% 0.0375 3.00% 0.0375


1.25 L

BI-z
0.25µL 12.00% 0.03 6.00% 0.015

1 。”L

ltl
1.00% 0.1 0.80% 0.08

’』Fll
0.5-10µL ”
0.1 L SµL 1.50% 0.075 1.50% 0.075

’』」flt
1µL 2.50% 0.025 1.50% 0.015

’E
20µL 0.90% 0.18 0.40% 0.08

’FIfIEla
2-20µL O.SµL 1 。”L 1.20% 0.12 1.00% 0.1
2µL 3.00% 0.06 2.00% 0.04

5。”L 0.60% 0.3 0.30% 0.15


5-SOµL O.SµL 25µL 0.90% 0.225 0.60% 0.15
SµL 2.00% 0.1 2.00% 0.1
100µL 0.80% 0.8 0.15% 0.15
10-100µL 1 µL 5。”L 1.00% 0.5 0.40% 0.2
lOµL 3.00% 0.3 1.50% 0.15
200µL 0.60% 1.2 0.15% 0.3
20-200µL ”
1 L 100µL 0.80% 0.8 0.30% 0.3

2。”L 3.00% 0.6 1.00% 0.2


200µL 。.60% 1.2 0.15% 0.3
50-200µL

1 L 100µL 0.80% 0.8 0.30% 0.3
SOµL 1.00% 0.5 0.40% 0.2
1000µL 0.60% 6 0.20% 2
100-100。”L ”
5 L SOOµL 0.70% 3.5 0.25% 1.25
100µL 2.00% 2 0.70% 0.7
1000µL 0.60% 6 0.20% 2
200-lOOOµL SµL SOOµL 0.70% 3.5 0.25% 1.25
200µL 0.90% 1.8 0.30% 0.6
SOOOµL 0.50% 25 0.15% 7.5
1000-SOOOµL SOµL 2500µL 。.60% 15 0.30% 7.5
1000µL 0.70% 7 0.30% 3
lOmL 。.60% 60 0.20% 20
2-10mL 0.1mL SmL 1.20% 60 0.30% 15
2mL 3.00% 60 0.60% 12

09
8-channel Adjustable Volume Pipettes

Volume
Range
II increment II Test V1 lu s e……
Maximum permissible

%
rror (I
µL
Maximum permissible

%口L

10µL 1.50% 0.15 1.50% 0.15


0.5-1 OµL O.lµL SµL 2.50% 0.125 2.50% 0.125


1 L 4.00% 0.04 4.00% 0.04
SOµL 1.00% 0.5 0.50% 0.25
5-SOµL
II O.SµL I. 25µL 1.50% 0.375 1.00% 0.25
SµL 3.00% 0.15 2.00% 0.1
300µL 0.70% 2.1 0.25% 0.75
50-300µL SµL 1 SOµL 1.00% 1.5 0.50% 0.75
SOµL 1.50% 0.75 0.80% 0.4

12-channel Adjustable Volume Pipettes


Maximum permissible Maximum permissible
Volume
Range
Increment II Test Vo Iume syst叫 ~
% µL % µL

10µL 1.50% 0.15 1.50% 0.15


0.5-lOµL O.lµL SµL 2.50% 0.125 2.50% 0.125
1µL 4.00% 0.04 4.00% 0.04
SOµL 1.00% 0.5 0.50% 0.25
5-SOµL II O.SµL [ 25µL 1.50% 0.375 1.00% 0.25
SµL 3.00% 0.15 2.00% 0.1
300µL 0.70% 2.1 0.25% 0.75
50-300µL SµL 1 SOµL 1.00% 1.5 0.50% 0.75
If
SOµL 1.50% 0.75 0.80% 0.4

Fixed v。lume Pipettes


Maximum permissible Maximum permissible
Volume
Range
II Inc陀ment 11 Test Vol e 制em…r(I…妙 …rror 川
川 ion)
% µL % µL

SµL SµL 1.3% 0.065 1.2% 0.06


10µL 10µL 0.8% 0.08 0.8% 0.08
|| || If
20µL 20µL 0.6% 0.12 0.5% 0.1
25µL ||
25µL 0.5% 0.125 0.3% 0.075
||
SOµL SOµL 0.5% 0.25 0.3% 0.15
100µL 100µL 0.5% 0.5 0.3% 0.3
|| ||
200µL 200µL 0.4% 0.8 0.2% 0.4

25。”L || ||
250µL 0.4% 1.0 0.2%
II 0.5
SOOµL SOOµL 0.3% 1.5 0.2% 1.0
1000µL 1000µL 0.3% 3.0 0.2% 2.0
|! ||
2000µL 2000µL 0.3% 6.0 0.15% 3.0
SOOOµL l SOOOµL 0.3% 15 0.15% || 7.5

,。

You might also like