455 Rosemount 2051 Product Document
455 Rosemount 2051 Product Document
April 2013
00813-0100-4101, Rev JA
Coplanar™ platform enables integration of primary elements, manifolds, and remote seal solutions
Best in Class performance with up to 0.05% high accuracy option
IEC 62591 (WirelessHART™) Protocol enables cost effective installations
Local Operator Interface (LOI) offers easy to use configuration capabilities at the transmitter
Protocols available include HART® 4-20 mA, FOUNDATION™ fieldbus, PROFIBUS PA, HART 1-5 Vdc Low
Power
Selectable HART Revision prepares your plant for the latest HART capabilities while ensuring seamless
integration with today's systems
SIL2 safety certification to IEC 61508 is available with the full 4-20 mA HART offering to simplify
compliance
Rosemount 2051 April 2013
Optimize safety with the industry's only intrinsically safe Power Module
Quickly deploy new pressure, level and flow measurements in 70% less time
Reduce straight pipe requirements, lower permanent pressure loss, and achieve
accurate measurement in small line sizes
Table of Contents
Rosemount 2051C Coplanar Pressure Transmitter . 3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Rosemount 2051T In-Line Pressure Transmitter . . . 12 Product certifications . . . . . . . . . . . . . . . . . . . . . . . . .60
Rosemount 2051CF Flowmeters . . . . . . . . . . . . . . . . 19 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . .68
Rosemount 2051L Liquid Level Transmitter . . . . . . . 42
2 [Link]
April 2013 Rosemount 2051
Additional Information
Specifications: page 50
Certifications: page 60
Dimensional Drawings: page 68
Table 1. Rosemount 2051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Measurement Type
Standard Standard
D Differential ★
G Gage ★
Pressure Range
Standard Standard
2051CD 2051CG
-25 to 25 inH2O (-62.2 to 62.2 ★
1 -25 to 25 inH2O (-62.2 to 62.2 mbar)
mbar)
-250 to 250 inH2O (-623 to 623 ★
2 -250 to 250 inH2O (-623 to 623 mbar)
mbar)
-1000 to 1000 inH2O (-2.5 to 2.5 ★
3 -393 to 1000 inH2O (-0.98 to 2.5 bar)
bar)
4 -300 to 300 psi (-20.7 to 20.7 bar) -14.2 to 300 psi (-0.98 to 20.7 bar) ★
[Link] 3
Rosemount 2051 April 2013
Transmitter Output
Standard Standard
(1) ★
A 4–20 mA with Digital Signal Based on HART Protocol
F FOUNDATION fieldbus Protocol ★
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
Materials of Construction
Standard Standard
Isolating Diaphragm
Standard Standard
5(3)(4) Tantalum
O-ring
Standard Standard
A Glass-filled PTFE ★
B Graphite-filled PTFE ★
Standard Standard
1 Silicone ★
(4) ★
2 Inert
4 [Link]
April 2013 Rosemount 2051
Standard Standard
Expanded
D Aluminum G½
M(5) SST G½
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Standard Standard
Alternate Flange(7)
Standard Standard
[Link] 5
Rosemount 2051 April 2013
Expanded
Manifold Assembly(8)(9)
Standard Standard
Standard Standard
Seal Assemblies(9)
Standard Standard
Mounting Brackets
Standard Standard
B4 Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST ★
6 [Link]
April 2013 Rosemount 2051
Product Certifications
Standard Standard
Standard Standard
[Link] 7
Rosemount 2051 April 2013
Shipboard Approvals
Standard Standard
Bolting Materials
Standard Standard
Standard Standard
M5 LCD display ★
Hardware Adjustments
Standard Standard
Flange Adapters
Standard Standard
DF(18) 1
/2-14 NPT Flange Adapters ★
Conduit Plug
Standard Standard
Expanded
Ground Screw
Standard Standard
Performance
Standard Standard
8 [Link]
April 2013 Rosemount 2051
Transient Protection
Standard Standard
Software Configuration
Standard Standard
Standard Standard
Pressure Testing
Expanded
Expanded
Standard Standard
P9 4500 psig (310 bar) Static Pressure Limit (2051CD Ranges 2-5 only) ★
Calibration Certification
Standard Standard
Q4 Calibration Certificate ★
Standard Standard
[Link] 9
Rosemount 2051 April 2013
Standard Standard
Surface Finish
Standard Standard
Standard Standard
Standard Standard
Standard Standard
(1) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART Revision
7 factory configured, add option code HR7.
(2) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(8) Not valid with optional code P9 for 4500 psi Static Pressure.
(9) “Assemble-to” items are specified separately and require a completed model number.
(10) Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).
10 [Link]
April 2013 Rosemount 2051
(14) Not available with FOUNDATION fieldbus output code F and Wireless Output Code X.
(15) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges, assemble-to
manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16 code), and remote
seal system report (QZ code).
(16) Only Available with HART 4-20 mA (output codes A and M).
(17) Only available with HART 4-20 mA Output (Output Codes A and M) and Wireless Output (Output Code X).
(18) Not valid with Alternate Process Connection options S3, S4, S5, S6.
(19) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(20) Not available with Alternate Process Connection: DIN Flanges and Level Flanges.
(21) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(22) Available with 4-20 mA HART output code A, Wireless output code X, FOUNDATION fieldbus output code F, 2051C Ranges 2-5 or 2051T Ranges 1-4, SST diaphragms and
silicone fill fluid. High Performance Option includes 0.05% Reference Accuracy, 5 year stability and improved ambient temperature effect specifications. See
Performance specifications for details.
(23) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(24) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(25) Only available with HART 4-20 mA output (output code A).
(26) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(27) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
[Link] 11
Rosemount 2051 April 2013
(1) The 4-20mA with Selectable HART device can be ordered with Transmitter
Output option code A plus any of the following options codes: M4, QT, DZ,
CR, CS, CT, HR5, HR7.
Additional Information
Specifications: page 50
Certifications: page 60
Dimensional Drawings: page 68
20 Ordering Information
Standard Standard
2051T In-Line Pressure Transmitter ★
Pressure Type
Standard Standard
G Gage ★
(1) ★
A Absolute
Pressure Range
Standard Standard
2051TG 2051TA ★
2 -14.7 to 150 psi (-1.0 to 10.3 bar) 0 to 150 psi (0 to 10.3 bar) ★
4 -14.7 to 4000 psi (-1.0 to 276 bar) 0 to 4000 psi (0 to 276 bar) ★
5 -14.7 to 10000 psi (-1.0 to 689 bar) 0 to 10000 psi (0 to 689 bar) ★
12 [Link]
April 2013 Rosemount 2051
Transmitter Output
Standard Standard
(2) ★
A 4–20 mA with Digital Signal Based on HART Protocol
F FOUNDATION fieldbus Protocol ★
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
Standard Standard
2B 1
/2–14 NPT female ★
2C(3) G1/2 A DIN 16288 male (Available in SST for Range 1-4 only) ★
Expanded
2F(4) Coned and Threaded, Compatible with Autoclave Type F-250-C (Range 5 only)
Standard Standard
2(5) 316L SST 316L SST ★
(5) ★
3 Alloy C-276 Alloy C-276
Standard Standard
1 Silicone ★
(4) ★
2 Inert
Housing Material Conduit Entry Size
Standard Standard
A Aluminum ½–14 NPT ★
Expanded
D Aluminum G½
(6)
M SST G½
[Link] 13
Rosemount 2051 April 2013
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Standard Standard
Manifold Assemblies
Standard Standard
Seal Assemblies
Standard Standard
(8) ★★
S1 Assemble to one Rosemount 1199 diaphragm seal
Mounting Bracket
Standard Standard
14 [Link]
April 2013 Rosemount 2051
Product Certifications
Standard Standard
(6) ★
E1 ATEX Flameproof
(6) ★
E2 INMETRO Flameproof
E3(6) China Flameproof ★
(6) ★
E4 TIIS Flameproof
E5 FM Explosion-proof, Dust Ignition-proof ★
Standard Standard
DW(9) NSF Drinking Water Approval ★
[Link] 15
Rosemount 2051 April 2013
Shipboard Approvals
Standard Standard
(4) ★
SBS American Bureau of Shipping (ABS) Type Approval
(4) ★
SBV Bureau Veritas (BV) Type Approval
SDN(4) Det Norske Veritas (DNV) Type Approval ★
(4) ★
SLL Lloyds Register (LR) Type Approval
Standard Standard
(10) ★
M4 LCD Display with Local Operator Interface
M5 LCD display ★
Hardware Adjustments
Standard Standard
D4(11) Zero and Span Configuration Buttons ★
Standard Standard
WSM(7) Wireless SST Sensor Module ★
Conduit Plug
Standard Standard
(4)(13) ★
DO 316 SST Conduit Plug
Ground Screw
Standard Standard
(4)(14) ★
V5 External Ground Screw Assembly
Performance
Standard Standard
P8(15) High Performance Option ★
Terminal Blocks
Standard Standard
(4)(16) ★
T1 Transient Protection Terminal Block
Software Configuration
Standard Standard
Custom Software Configuration (Completed CDS 00806-0100-4101 or 00806-0100-4100 for Wireless ★
C1(12)
required with order)
16 [Link]
April 2013 Rosemount 2051
Alarm Limits
Standard Standard
(11)(17) ★
C4 Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
(11)(18) ★
CN Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm Low
CR(11) Custom Alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet) ★
(11) ★
CS Custom Alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
(11) ★
CT Low Alarm (standard Rosemount alarm and saturation levels)
Pressure Testing
Expanded
Expanded
Calibration Certification
Standard Standard
Q4 Calibration Certificate ★
Standard Standard
Q8 Material Traceability Certification per EN 10204 3.1 ★
Standard Standard
QS(18) Prior-use certificate of FMEDA data ★
(18) ★
QT Safety Certified to IEC 61508 with certificate of FMEDA
Surface Finish
Standard Standard
Q16 Surface finish certification for sanitary remote seals ★
Standard Standard
QZ Remote Seal System Performance Calculation Report ★
[Link] 17
Rosemount 2051 April 2013
Standard Standard
(4) ® ★
GE M12, 4-pin, Male Connector (eurofast )
(4) ® ★
GM A size Mini, 4-pin, Male Connector (minifast )
Standard Standard
(11)(20) ★
HR5 Configured for HART Revision 5
(11)(21) ★
HR7 Configured for HART Revision 7
(1) Wireless Output (code X) only available in absolute measurement type (code A) in range 1-5 with 1/2 14 NPT process connection (code 2B), and housing code (code
P)
(2) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART
Revision 7 factory configured, add option code HR7.
(3) Wireless output (code X) only available in G1/2 A DIN 16288 Male process connection (code 2C) with range 1-4, 316 SST isolating diaphragm (code 2), silicone fill
fluid (code 1), and housing code (code P).
(5) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(8) “Assemble-to” items are specified separately and require a completed model number.
(9) Not available with coned and threaded connection (2F code), assemble-to manifold (S5 code), assemble-to seal (S1 code), surface finish certification (Q16 code),
remote seal system report (QZ code).
(10) Not available with FOUNDATION fieldbus output code F or Wireless output code X
(11) Only Available with HART 4-20 mA (output codes A and M).
(12) Only available with HART 4-20 mA Output (output code A and M) and Wireless Output (output code X).
(13) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(14) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(15) Available with 4-20 mA HART output code A, Wireless output code X, FOUNDATION fieldbus output code F, 2051C Ranges 2-5 or 2051T Ranges 1-4, SST diaphragms
and silicone fill fluid. High Performance Option includes 0.05% Reference Accuracy, 5 year stability and improved ambient temperature effect specifications. See
Performance Specifications for details.
(16) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(17) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(18) Only available with HART 4-20 mA output (output code A).
(20) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(21) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
18 [Link]
April 2013 Rosemount 2051
(1) The 4-20 mA with Selectable HART device can be ordered with Transmitter
Output option code A plus any of the following options codes: M4, QT, DZ,
CR, CS, CT, HR5, HR7.
Additional Information
Specifications: page 50
Rosemount 2051CFA Annubar Certifications: page 60
Flowmeter
Dimensional Drawings: page 68
Standard Standard
D Differential Pressure ★
Fluid Type
Standard Standard
L Liquid ★
G Gas ★
S Steam ★
[Link] 19
Rosemount 2051 April 2013
Line Size
Standard Standard
Standard Standard
Expanded
A Range A from the Pipe I.D. table
B Range B from the Pipe I.D. table
E Range E from the Pipe I.D. table
Z Non-standard Pipe I.D. Range or Line Sizes greater than 12 in.
Pipe Material / Mounting Assembly Material
Standard Standard
Standard Standard
H Horizontal Piping ★
20 [Link]
April 2013 Rosemount 2051
Annubar Type
Standard Standard
P Pak-Lok ★
Sensor Material
Standard Standard
Sensor Size
Standard Standard
1 Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm) ★
2 Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm) ★
Mounting Type
Standard Standard
A3 300# RF ANSI ★
A6 600# RF ANSI ★
D1 DN PN16 Flange ★
D3 DN PN40 Flange ★
D6 DN PN100 Flange ★
Expanded
R1 150# RTJ Flange
R3 300# RTJ Flange
R6 600# RTJ Flange
Opposite Side Support or Packing Gland
Standard Standard
0 No opposite side support or packing gland (Required for Pak-Lok and Flange-Lok models) ★
Standard Standard
[Link] 21
Rosemount 2051 April 2013
Temperature Measurement
Standard Standard
T Integral RTD – not available with Flanged model greater than class 600# ★
0 No Temperature Sensor ★
Expanded
R Remote Thermowell and RTD
Transmitter Connection Platform
Standard Standard
3 Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600 ★
5 Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600 ★
1 ★
7 Remote-mount NPT Connections ( /2-in. FNPT)
Expanded
8 Remote-mount SW Connections (1/2-in.)
Differential Pressure Range
Standard Standard
Transmitter Output
Standard Standard
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
M Low-Power, 1-5 Vdc with Digital Signal Based on HART Protocol
Transmitter Housing Material Conduit Entry Size
Standard Standard
1 ★
A Aluminum /2-14 NPT
B Aluminum M20 x 1.5 ★
1 ★
J SST /2-14 NPT
K(3) SST M20 x 1.5 ★
Expanded
D Aluminum G1/2
M(3) SST G1/2
22 [Link]
April 2013 Rosemount 2051
Standard Standard
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART ★
Antenna and SmartPower
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Expanded
P1(3)(5) Hydrostatic Testing with Certificate
(3)(5)
PX Extended Hydrostatic Testing
Special Cleaning
Expanded
P2(3) Cleaning for Special Services
PA(3) Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1(3) Dye Penetrant Exam
Material Examination
Expanded
V2(3) Radiographic Examination
Special Inspection
Standard Standard
Standard Standard
RL(3) Surface finish for Low Pipe Reynolds # in Gas & Steam ★
(3) ★
RH Surface finish for High Pipe Reynolds # in Liquid
[Link] 23
Rosemount 2051 April 2013
Standard Standard
Code Conformance
Expanded
J2 (3) ANSI/ASME B31.1
(3)
J3 ANSI/ASME B31.3
Materials Conformance
Expanded
J5(3)(7) NACE MR-0175 / ISO 15156
Country Certification
Standard Standard
Expanded
J1(3) Canadian Registration
Instrument Connections for Remote Mount Options
Standard Standard
Expanded
G1(3) Needle Valves, Carbon Steel
(3)
G3 Needle Valves, Alloy C-276
G5(3) OS&Y Gate Valve, Carbon Steel
(3)
G7 OS&Y Gate Valve, Alloy C-276
Special Shipment
Standard Standard
24 [Link]
April 2013 Rosemount 2051
Product Certifications
Standard Standard
K7(3) IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7) ★
(3) ★
KA ATEX and CSA Flameproof, Intrinsically Safe, Division 2
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6,
KB ★
I5, and I6)
KC(3) FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★
(3) ★
KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
N1(3) ATEX Type n ★
(3) ★
N7 IECEx Type n
(3) ★
ND ATEX Dust
Sensor Fill Fluid and O-ring Options
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Hardware Adjustments
Standard Standard
Alarm Limit
Standard Standard
Ground Screw
Standard Standard
26 [Link]
April 2013 Rosemount 2051
Standard Standard
(1) Provide the “A” dimension for Flanged (page 77) and Pak-Lok (page 77).
(2) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART
Revision 7 factory configured, add option code HR7.
(6) Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
(7) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(10) Not available with FOUNDATION Fieldbus (Output Code F) or Wireless (Output Code X)
(12) Not available with Housing code 00, 5A or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product
Certification code IA.
(13) Only available with 4-20 mA HART (output codes A and M).
(14) Only available with HART 4-20 mA Output (output codes A and M) and Wireless Output (output code X).
(15) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(16) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(17) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(18) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
[Link] 27
Rosemount 2051 April 2013
Additional Information
Rosemount 2051CFC Compact Flowmeter Specifications: page 50
Certifications: page 60
Dimensional Drawings: page 68
Standard Standard
D Differential Pressure ★
Standard Standard
Material Type
Standard Standard
S 316 SST ★
Line Size
Standard Standard
005(1) 1
/2-in. (15 mm) ★
Standard Standard
N Square Edged ★
28 [Link]
April 2013 Rosemount 2051
Standard Standard
Standard Standard
0 No Temperature Sensor ★
Expanded
R Remote Thermowell and RTD
Transmitter Connection Platform
Standard Standard
Standard Standard
Transmitter Output
Standard Standard
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
M Low-Power, 1-5 Vdc with Digital Signal Based on HART Protocol
Transmitter Housing Material Conduit Entry Size
Standard Standard
A Aluminum 1
/2-14 NPT ★
J SST 1
/2-14 NPT ★
Expanded
D Aluminum G1/2
(4)
M SST G1/2
[Link] 29
Rosemount 2051 April 2013
Standard Standard
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART ★
Antenna and SmartPower
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Standard Standard
AB(4) ANSI Alignment Ring (150#) (Only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) ★
(4) ★
AC ANSI Alignment Ring (300#) (Only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes)
AD (4) ANSI Alignment Ring (600#) (Only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) ★
(4) ★
DG DIN Alignment Ring (PN16)
(4) ★
DH DIN Alignment Ring (PN40)
DJ(4) DIN Alignment Ring (PN100) ★
Expanded
JB(4) JIS Alignment Ring (10K)
(4)
JR JIS Alignment Ring (20K)
JS(4) JIS Alignment Ring (40K)
Remote Adapters
Standard Standard
Expanded
HT(4) Graphite Valve Packing (Tmax = 850 °F)
Flow Calibration
Expanded
WC(4)(6) Flow Calibration Certification (3 point)
(4)(6)
WD Discharge Coefficient Verification (full 10 point)
30 [Link]
April 2013 Rosemount 2051
Pressure Testing
Expanded
P1(4) Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2(4) Cleaning for Special Services
(4)
PA Cleaning per ASTM G93 Level D (Section 11.4)
Special Inspection
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Code Conformance
Expanded
J2(4) ANSI/ASME B31.1
J3(4) ANSI/ASME B31.3
(4)
J4 ANSI/ASME B31.8
Materials Conformance
Expanded
J5(4)(8) NACE MR-0175 / ISO 15156
Country Certification
Expanded
J1(4) Canadian Registration
[Link] 31
Rosemount 2051 April 2013
Product Certifications
Standard Standard
K6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6) ★
K7(4) IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7) ★
(4) ★
KA ATEX and CSA Flameproof, Intrinsically Safe, Division 2
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, ★
KB
I5, and I6)
KC(4) FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★
(4) ★
KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
N1(4) ATEX Type n ★
(4) ★
N7 IECEx Type n
(4) ★
ND ATEX Dust
Sensor Fill Fluid and O-ring Options
Standard Standard
Standard Standard
Transient Protection
Standard Standard
Standard Standard
Alarm Limit
Standard Standard
Standard Standard
Hardware Adjustments
Standard Standard
Ground Screw
Standard Standard
Standard Standard
(2) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
(3) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART
Revision 7 factory configured, add option code HR7.
[Link] 33
Rosemount 2051 April 2013
(7) Not available with FOUNDATION Fieldbus (Output Code F) or Wireless (Output Code X).
(8) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(11) Not available with Housing code 00, 5A, or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product
Certification code IA.
(12) Only available with 4-20 mA HART (output codes A and M).
(13) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(14) Only available with HART 4-20 mA (Output Codes A and M) and Wireless (Output Code X).
(15) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(16) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(17) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if 14 needed.
34 [Link]
April 2013 Rosemount 2051
Additional Information
Specifications: page 50
Rosemount 2051CFP Integral Certifications: page 60
Orifice Flowmeter
Dimensional Drawings: page 68
Standard Standard
D Differential Pressure ★
Material Type
Standard Standard
S 316 SST ★
Line Size
Standard Standard
005 1
/2-in. (15 mm) ★
Process Connection
Standard Standard
T1 NPT Female Body (Not Available with Remote Thermowell and RTD) ★
S1(1) Socket Weld Body (Not Available with Remote Thermowell and RTD) ★
[Link] 35
Rosemount 2051 April 2013
Expanded
A1 Pipe Ends: Flanged, RF, ANSI Class 150, slip-on
A3 Pipe Ends: Flanged, RF, ANSI Class 300, slip-on
A6 Pipe Ends: Flanged, RF, ANSI Class 600, slip-on
R1 Pipe Ends: Flanged, RTJ, ANSI Class 150, slip-on
R3 Pipe Ends: Flanged, RTJ, ANSI Class 300, slip-on
R6 Pipe Ends: Flanged, RTJ, ANSI Class 600, slip-on
Orifice Plate Material
Standard Standard
S 316 SST ★
Standard Standard
Expanded
0010 0.010-in. (0.25 mm) for 1/2-in. Pipe
0014 0.014-in. (0.36 mm) for 1/2-in. Pipe
0020 0.020-in. (0.51 mm) for 1/2-in. Pipe
0034 0.034-in. (0.86 mm) for 1/2-in. Pipe
36 [Link]
April 2013 Rosemount 2051
Standard Standard
Standard Standard
Transmitter Output
Standard Standard
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
M Low-Power, 1-5 Vdc with Digital Signal Based on HART Protocol
Transmitter Housing Material Conduit Entry Size
Standard Standard
J SST 1
/2-14 NPT ★
(3) ★
K SST M20 x 1.5
P(4) Engineered Polymer No Conduit Entries ★
Expanded
D Aluminum G1/2
M(3) SST G1/2
Transmitter Performance Class
Standard Standard
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART ★
[Link] 37
Rosemount 2051 April 2013
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Expanded
RT(3)(5) Thermowell and RTD
Optional Connection
Standard Standard
Pressure Testing
Expanded
P1(3)(6) Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2(3) Cleaning for Special Services
(3)
PA Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1(3) Dye Penetrant Exam
Material Examination
Expanded
V2(3) Radiographic Examination
Flow Calibration
Expanded
WD(3)(7) Discharge Coefficient Verification
Special Inspection
Standard Standard
Standard Standard
38 [Link]
April 2013 Rosemount 2051
Code Conformance
Expanded
J2(3)(8) ANSI/ASME B31.1
J3(3)(8) ANSI/ASME B31.3
(3)(8)
J4 ANSI/ASME B31.8
Materials Conformance
Expanded
J5(3)(9) NACE MR-0175 / ISO 15156
Country Certification
Standard Standard
Expanded
J1(3) Canadian Registration
Transmitter Calibration Certification
Standard Standard
Standard Standard
Standard Standard
[Link] 39
Rosemount 2051 April 2013
IA(3)(11) ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only ★
(3)(11) ★
IE FM FISCO Intrinsically Safe
(3)(11) ★
IF CSA FISCO Intrinsically Safe
(3)(11) ★
IG IECEx FISCO Intrinsically Safe
K1(3)(11) ATEX Flameproof, Intrinsic Safety, Type n, Dust ★
K6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6) ★
K7(3) IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7) ★
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, ★
KB
and I6)
KC(3) FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★
(3) ★
KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
N1(3) ATEX Type n ★
(3) ★
N7 IECEx Type n
(3) ★
ND ATEX Dust
Sensor Fill Fluid and O-ring Options
Standard Standard
Standard Standard
Transient Protection
Standard Standard
Alarm Limit
Standard Standard
Standard Standard
40 [Link]
April 2013 Rosemount 2051
Hardware Adjustments
Standard Standard
Ground Screw
Standard Standard
Standard Standard
(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
(2) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART Revision
7 factory configured, add option code HR7.
(7) Not available for bore sizes 0010, 0014, 0020, or 0034.
(8) Not available with DIN Process Connection codes D1, D2, or D3.
(9) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(10) Not available with FOUNDATION Fieldbus (Output Code F) or Wireless (Output Code X).
(13) Not available with Housing code 00, 5A, or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product
Certification code IA.
(14) Only available with 4-20 mA HART (output codes A and M).
(15) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(16) Only available with HART 4-10 mA (Output Codes A and M) and Wireless (Output Code X).
(17) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(18) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(19) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
[Link] 41
Rosemount 2051 April 2013
(1) The 4-20mA with Selectable HART device can be ordered with Transmitter
Output option code A plus any of the following options codes: M4, QT, DZ,
CR, CS, CT, HR5, HR7.
Additional Information
Specifications: page 50
Certifications: page 60
Dimensional Drawings: page 68
Table 6. Rosemount 2051L Liquid Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for
best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Transmitter Type
Standard Standard
Pressure Range
Standard Standard
Transmitter Output
Standard Standard
W PROFIBUS PA Protocol ★
X Wireless ★
Expanded
42 [Link]
April 2013 Rosemount 2051
Standard Standard
G(2) 2 in./DN 50 316L SST ★
(2) ★
H 2 in./DN 50 Alloy C-276
J 2 in./DN 50 Tantalum ★
E 3 in./DN 80 Tantalum ★
Standard Standard
2 2 in./50 mm ★
4 4 in./100 mm ★
6 6 in./150 mm ★
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Standard Standard
A Glass-filled PTFE ★
44 [Link]
April 2013 Rosemount 2051
Standard Standard
Expanded
D Aluminum G½
(5)
M SST G½
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) ★
Standard Standard
Seal Assemblies
Standard Standard
Product Certifications
Standard Standard
[Link] 45
Rosemount 2051 April 2013
Standard Standard
Standard Standard
M5 LCD display ★
46 [Link]
April 2013 Rosemount 2051
Standard Standard
Flange Adapters
Standard Standard
DF(12) 1
/2-14 NPT Flange Adapters ★
Conduit Plug
Standard Standard
Ground Screw
Standard Standard
Transient Protection
Standard Standard
Software Configuration
Standard Standard
Alarm Limit
Standard Standard
CR(10) Custom Alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet) ★
CS(10) Custom Alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet) ★
Calibration Certification
Standard Standard
Q4 Calibration Certificate ★
[Link] 47
Rosemount 2051 April 2013
Standard Standard
Standard Standard
Standard Standard
Standard Standard
Standard Standard
F1 316 SST 1 1
/4-18 NPT ★
F2 316 SST 2 1
/4-18 NPT ★
F8 316 SST 2 1
/2-14 NPT ★
F9 Alloy C-276 1 1
/2-14 NPT ★
F0 Alloy C-276 2 1
/2-14 NPT ★
Standard Standard
(1) HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order HART
Revision 7 factory configured, add option code HR7.
(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
48 [Link]
April 2013 Rosemount 2051
(8) “Assemble-to” items are specified separately and require a completed model number.
(9) Not valid with FOUNDATION fieldbus output code F and Wireless Output Code X.
(10) Only available with 4-20 mA HART (output codes A and M).
(11) Only available with HART 4-20 mA output (output codes A and M) and Wireless output (output code X).
(12) Not available with Remote Mount Seal Assembly option S1.
(13) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(14) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(15) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.
(17) Only available with HART 4-20 mA output (output code A).
(18) Not available with Option Codes A0, B0, and G0.
(19) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(20) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
[Link] 49
Rosemount 2051 April 2013
Specifications
Performance specifications
This product data sheet covers HART, Wireless, FOUNDATION fieldbus, and PROFIBUS PA protocols unless specified.
Reference accuracy
Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability. For Wireless, FOUNDATION fieldbus, and PROFIBUS
PA devices, use calibrated range in place of span.
±0.075% of span
For spans less than 10:1,
Range 5
accuracy = 0.075 --------------- % of Span
URL
Span
±0.075% of span
2051L For spans less than 10:1, accuracy =
Ranges 2-4
0.025 + 0.005 --------------- % of Span
URL
Span
50 [Link]
April 2013 Rosemount 2051
Dynamic performance
0%
(1) Dead time and update rate apply to all models and ranges; analog output only Time
(2) Nominal total response time at 75 °F (24 °C) reference conditions.
(3) Transducer block response time, Analog Input block execution time not included.
(4) Does not apply to wireless (Output Code X). See “Wireless (Output Code X)” on page 55
for wireless update rate.
[Link] 51
Rosemount 2051 April 2013
2051T
±(0.05% URL + 0.25% span) from 1:1 to 30:1 ±(0.025% URL + 0.125% span) from 1:1 to 30:1
Range 2-4
±(0.07% URL + 0.25% span) from 30:1 to 100:1 ±(0.035% URL + 0.125% span) from 30:1 to 100:1
±(0.05% URL + 0.25% span) from 1:1 to 10:1 ±(0.025% URL + 0.125% span) from 1:1 to 10:1
Range 1
±(0.10% URL + 0.25% span) from 10:1 to 100:1 ±(0.05% URL + 0.125% span) from 10:1 to 100:1
Range 5 ±(0.1% URL + 0.15% span)
2051L See Instrument Toolkit
52 [Link]
April 2013 Rosemount 2051
Functional specifications
Range and Sensor limits
Minimum
Upper Lower Lower(1)
Span
(URL) (LRL) (Abs) (LRL) (Gage)
0.3 psi 30 psi 0 psia –14.7 psig
1
(20.6 mbar) (2.06 bar) (0 bar) (–1.01 bar)
1.5 psi 150 psi 0 psia –14.7 psig
2
(0.103 bar) (10.3 bar) (0 bar) (–1.01 bar)
8 psi 800 psi 0 psia –14.7 psig
3
(0.55 bar) (55.2 bar) (0 bar) (–1.01 bar)
40 psi 4000 psi 0 psia –14.7 psig
4
(2.76 bar) (275.8 bar) (0 bar) (–1.01 bar)
2,000 psi 10,000 psi 0 psia –14.7 psig
5
(137.9 bar) (689.4 bar) (0 bar) (–1.01 bar)
Service
Liquid, gas, and vapor applications
[Link] 53
Rosemount 2051 April 2013
1000
Indication
500 Operating
Optional two line LCD display
Region
0 FOUNDATION fieldbus function block
10.5 20 30 Execution times
Voltage (Vdc) 42.4(1)
Communication requires a minimum Block Execution Time
loop resistance of 250 ohms. Resource -
(1) For CSA approval, power supply must not exceed 42.4 V. Transducer -
LCD Block -
Indication Analog Input 1, 2 30 milliseconds
Optional two line LCD/LOI Display PID 45 milliseconds
Zero and span adjustment requirements Input Selector 30 milliseconds
Zero and span values can be set anywhere within the range limits stated Arithmetic 35 milliseconds
in Table 7 and Table 8. Signal Characterizer 40 milliseconds
Integrator 35 milliseconds
Span must be greater than or equal to the minimum span stated
in Table 7 and Table 8. FOUNDATION fieldbus parameters
Output Schedule Entries 7 (max.)
Links 20 (max.)
Two-wire 4-20mA, user selectable for linear or square root
output. Digital process variable superimposed on 4-20 mA Virtual Communications Relationships
12 (max.)
(VCR)
signal, available to any host that conforms to HART protocol.
2051 Standard function blocks
Digital communications based on HART Revision 5 protocol. Resource block
2051 with selectable HART Contains hardware, electronics, and diagnostic
information.
The 2051 with Selectable HART comes with Selectable HART
Revisions. Digital communications based on HART Revision 5 Transducer block
(default) or Revision 7 (option code HR7) protocol can be Contains actual sensor measurement data including the
selected. The HART revision can be switched in the field using sensor diagnostics and the ability to trim the pressure
any HART based configuration tool or the optional local operator sensor or recall factory defaults.
interface (LOI). LCD block
Configures the local display.
2 Analog input blocks
Processes the measurements for input into other
function blocks. The output value is in engineering units
or custom and contains a status indicating
measurement quality.
54 [Link]
April 2013 Rosemount 2051
[Link] 55
Rosemount 2051 April 2013
2051C, 2051CF (2) Wireless LCD display may not be readable and LCD updates will be
slower at temperatures below -4 °F (-20 °C)
• Ranges 2–5: 3,626 psig (250 bar)
4,500 psig (310,3 bar) for option code P9
• Range 1: 2,000 psig (137,9 bar)
2051T
• Range 1: 750 psi (51,7 bar)
• Range 2: 1,500 psi (103,4 bar)
• Range 3: 1,600 psi (110,3 bar)
• Range 4: 6,000 psi (413,7 bar)
• Range 5: 15,000 psi (1034,2 bar)
56 [Link]
April 2013 Rosemount 2051
Process 2051
At atmospheric pressures and above. See Table 10. Analog output response to a step input change is
Table 10. Process Temperature Limits user-selectable from 0 to 36 seconds for one time
constant. This software damping is in addition to
2051C, 2051CF sensor module response time.
(1)
Silicone Fill Sensor
FOUNDATION fieldbus
with Coplanar Flange –40 to 250 °F (–40 to 121 °C)(2)
Transducer block: 0.4 seconds fixed
with Traditional Flange –40 to 300 °F (–40 to 149 °C)(2)(3)
AI Block: User configurable
with Level Flange –40 to 300 °F (–40 to 149 °C)(2)
with 305 Integral PROFIBUS PA
–40 to 300 °F (–40 to 149 °C)(2)
Manifold AI Block only: User configurable
Inert Fill Sensor(1) –40 to 185 °F (–40 to 85 °C)(3) Failure mode alarm
2051T (Process Fill Fluid)
Silicone Fill Sensor(1) -40 to 250 °F (-40 to 121 °C)(2) HART 4-20 mA (Output Code A)
Inert Fill Sensor(1) -22 to 250 °F (-30 to 121 °C)(2) If self-diagnostics detect a sensor or microprocessor failure, the
analog signal is driven either high or low to alert the user. High or
2051L Low-Side Temperature Limits
low failure mode is user-selectable with a jumper on the
Silicone Fill Sensor(1) –40 to 250 °F (–40 to 121 °C)(2) transmitter. The values to which the transmitter drives its
Inert Fill Sensor(1) -22 to 250 °F (-30 to 121 °C) (2) output in failure mode depend on whether it is
2051L High-Side Temperature Limits (Process Fill Fluid) factory-configured to standard or NAMUR-compliant operation.
Syltherm® XLT –100 to 300 °F (–73 to 149 °C) The values for each are as follows:
D.C. Silicone 704 ® 60 to 400 °F (15 to 205 °C) Standard Operation
D.C. Silicone 200 –40 to 400 °F (–40 to 205 °C) Output Code Linear Output Fail High Fail Low
Inert –50 to 350 °F (–45 to 177 °C) A 3.9 I 20.8 I 21.75 mA I 3.75 mA
Glycerin and Water 0 to 200 °F (–17 to 93 °C) M 0.97 V 5.2 V 5.4 V V 0.95 V
Neobee M-20 0 to 400 °F (–17 to 205 °C)
NAMUR-Compliant Operation
Propylene Glycol and
0 to 200 °F (–17 to 93 °C)
Water Output Code Linear Output Fail High Fail Low
A 3.8 I 20.5 I 22.5 mA I 3.6 mA
(1) Process temperatures above 185 °F (85 °C) require derating the ambient
limits by a 1.5:1 ratio. Output code F and X
If self-diagnostics detect a gross transmitter failure, that
(2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below information gets passed as a status along with the process
0.5 psia. variable.
(3) 160 °F (71 °C) limit in vacuum service.
Physical specifications
Humidity limits
0–100% relative humidity
Electrical connections
1
/2–14 NPT, G1/2, and M20 × 1.5 conduit.
Volumetric displacement
Less than 0.005 in3 (0.08 cm3)
Process connections
2051C
Damping • 1/4–18 NPT on 21/8-in. centers
• 1/2–14 NPT and RC 1/2 on 2-in.(50,8 mm), 21/8-in. (54,0 mm), or
4-20 mA HART 21/4-in. (57,2 mm) centers (process adapters)
2051 with selectable HART 2051T
Analog output response to a step input change is • 1/2–14 NPT female
user-enterable from 0.0 to 60 seconds for one time • G1/2 A DIN 16288 Male (available in SST for Range 1–4 transmitters
constant. This software damping is in addition to only)
sensor module response time. • Autoclave type F-250-C (Pressure relieved 9/16–18 gland thread; 1/4
OD high pressure tube 60° cone; available in SST for Range 5
transmitters only)
[Link] 57
Rosemount 2051 April 2013
Flanged process connection (Transmitter high side) (1) Transmitter weights include the sensor module and housing only
Process diaphragms, Including process gasket surface (aluminum for standard 2051 and polymer for wireless).
58 [Link]
April 2013 Rosemount 2051
[Link] 59
Rosemount 2051 April 2013
Product certifications
Approved manufacturing locations I5 Intrinsically-Safe and Non-incendive
Certificate No: 3033457
Rosemount Inc. — Chanhassen, Minnesota USA
Applicable Standards: FM Class 3600 – 1998, FM Class
Emerson Process Management GmbH & Co. — Wessling,
3610 – 2007, FM Class 3611 – 2004, FM Class 3810 – 2005
Germany
Markings: Intrinsically Safe for use in Class I, Division 1,
Emerson Process Management Asia Pacific
Groups A, B, C, and D; Class II, Divisions 1, Groups E, F, and
Private Limited — Singapore
G; Class III, Division 1; Class I, Zone 0, AEx ia IIC;
Beijing Rosemount Far East Instrument Co., LTD — Beijing, China Nonincendive for use in Class I, Division 2, Groups A, B, C
Emerson Process Management LTDA — Sorocaba, Brazil and D; in accordance with Control Drawing 02051-1009
Emerson Process Management (India) Pvt. Ltd — Daman, India T4 (-50 °C to +70 °C) Enclosure Type 4X
Temperature Code:T4 (Ta = -50 °C to +70 °C),
European directive information
Enclosure Type 4X
The EC declaration of conformity for all applicable European directives
for this product can be found on the Rosemount website at
For input parameters see control drawing 02051-1009.
[Link]. A hard copy may be obtained by contacting an
Emerson Process Management representative. Special Conditions for Safe Use:
60 [Link]
April 2013 Rosemount 2051
Inmetro Certifications
E3 Flame-Proof
NEPSI Certificate No: GYJ101321X
Applicable standards: GB3836.1-2000, GB3836.2-2000
Markings: Ex d II C T5/T6
T6 = -50 °C Tamb 80 °C
T5 = -50 °C Tamb 65 °C
I3 Intrinsic Safety
Certificate No: GYJ101320X
Applicable Standards: GB3836.1-2000, GB3836.4-2000
Markings: Ex ia IIC T4
T4: -60 °C Tamb 70 °C
China (NEPSI) Certifications
E3 Flame-Proof
Ex d IIC T5/T6
I3 Intrinsic Safety
Ex ia IIC T4
CCOE Certifications
IW Intrinsic Safety
Ex ia IIC T4
EW Flame-Proof
Ex d IIC T5
62 [Link]
April 2013 Rosemount 2051
For FOUNDATION fieldbus and PROFIBUS PA, Temperature Special Conditions for Safe Use (X):
Code: T4 (Ta = -50 °C to +70 °C)
When the optional transient protection terminal block is
For FISCO, installed, the apparatus is not capable of withstanding the
Temperature Code: T4 (Ta = -50 °C to +60 °C) 500 V insulation test required by Clause 6.3.12 of
EN60079-11. This must be taken into account when
Enclosure Type 4X installing the apparatus.
For input parameters see control drawing 02051-1009.
IA ATEX FISCO Intrinsic Safety
Canadian Standards Association (CSA) Certificate No: Baseefa08ATEX0129X
Applicable Standards: EN60079-0:2012,
All CSA hazardous approved transmitters are certified per
EN60079-11:2012
ANSI/ISA 12.27.01-2003.
Markings: II 1 G Ex ia IIC T4 Ga(–60 °C Ta +60 °C)
E6 Explosion-Proof, Dust Ignition Proof IP66 IP68
Certificate No: 2041384 1180
Applicable Standards: CSA Std. C22.2 No. 142 - M1987,
CSA Std. C22.2 No. 30 - M1986, CSA Std. C22.2 No. 213 - Table 17. Input Parameters
M1987, CAN/CSA-E60079-0:07, Ui = 30 V
CAN/CSA-E60079-1:07 Ii = 200 mA
Pi = 1.0 W
Markings: Explosion-Proof for Class I, Division 1, Groups B,
Ci = 0.012 μF
C, and D. Dust-Ignitions Proof for Class II and Class III,
Division 1, Groups E, F, and G. Suitable for Class I, Division
Special Conditions for Safe Use (X):
2, Groups A, B, C, and D for indoor and outdoor hazardous
locations. Class I Zone 1 Ex d IIC T5. Enclosure type 4X, When the optional transient protection terminal block is
factory sealed. Single Seal. installed, the apparatus is not capable of withstanding the
500 V insulation test required by Clause 6.3.12 of
EN60079-11. This must be taken into account when
I6/IF Intrinsically Safe installing the apparatus.
Certificate no.: 2041384
Applicable Standards: CSA Std. C22.2 No. 142 - M1987,
CSA Std. C22.2 No. 213 - M1987, CSA Std. C22.2 No. 157 -
92, CSA Std. C22.2 No. 213 - M1987, ANSI/ISA 12.27.01 -
2003, CAN/CSA-E60079-0:07, CAN/CSA-E60079-11:02
[Link] 63
Rosemount 2051 April 2013
1. Appropriate ex d blanking plugs, cable glands, and Table 19. Input Parameters
wiring needs to be suitable for a temperature of 90 °C. Ui = 17.5 V
2. This device contains a thin wall diaphragm. Installation, Ii = 380 mA
maintenance, and use shall take into account the Pi = 5.32 W
environmental conditions to which the diaphragm will be Ci = 5 μF
subjected. The manufacturer’s instructions for Li = 10 μH
maintenance shall be followed in detail to assure safety
during its expected lifetime. Special Conditions for Safe Use (X):
3. In case of repair, Contact Emerson Process Management The device is not capable of withstanding the 500 V
for information on the dimensions of flameproof joints. insulation test required by Clause 6.3.12 of IEC 60079-11.
This must be taken into account when installing the
ND ATEX Dust apparatus.
Certification No. Baseefa08ATEX0182X
Applicable Standards: EN60079-0:2012, EN E7 IECEx Flame-Proof
60079-31:2009 Certification No. IECEx KEM 08.0024X
Markings: II 1 D Ex t IIIC T50 °C T500 60 °C Da Applicable Standards: IEC60079-0:2011,
IP66 IP68 IEC60079-1:2007-04, IEC60079-26:2006
Ui = 42.4 Vdc Ex d IIC T6 Ga/Gb (–50 °C Ta 65 °C)
1180 Ex d IIC T5 Ga/Gb (–50 °C Ta 80 °C)
Ui = 32 Vdc
Special Conditions for Safe Use (X):
64 [Link]
April 2013 Rosemount 2051
TIIS Certifications
E4 TIIS Flame-Proof
Ex d IIC T6
E3 Flameproof
NEPSI Certificate No.: GYJ101321X
Applicable Standards: GB3836.1-2000, GB3836.2-2000
Markings: Ex d II C T5/T6
T5: –50 °C Ta +80 °C
T6: –50 °C Ta +65 °C
I3 Intrinsic Safety
NEPSI Certificate No.: GYJ101320X
Applicable Standards: GB3836.1-2000, GB3836.4-2000
Markings: Ex ia IIC T4
T4: –60 °C Ta +70 °C
Inmetro Certifications
E2 Flameproof
Certificate No: CEPEL 09.1767X
Ex d IIC T* Ga/Gb IP66
T6 = -50 °C < Tamb < 65 °C
T5 = -50 °C < Tamb < 80 °C
I2 Intrinsic Safety
Certificate No: CEPEL 09.1768X
Ex ia IIC T4 Ga (-60°C < Tamb < +70°C) IP66
[Link] 65
Rosemount 2051 April 2013
66 [Link]
April 2013 Rosemount 2051
[Link] 67
Rosemount 2051 April 2013
Dimensional drawings
2051C Exploded View
Nameplate
Local Configuration Buttons(1)
Electronics Housing
Terminal Block
Cover O-ring
Cover
Electronics Board
Sensor Module
Coplanar Flange
Process O-Ring
Drain/Vent Valve
Flange Adapters
Flange Bolts
1) Span and Zero Adjustment Buttons are optional with 4-20 mA and 1-5 Vdc HART protocol. Local Operator Interface buttons are
optional for PROFIBUS PA protocol. Local Configuration Buttons are not available with FOUNDATION fieldbus.
68 [Link]
April 2013 Rosemount 2051
Fieldbus
7.03 (179) Display Cover
HART Display
Terminal
Cover
Connections
Transmitter
Circuitry
6.40 (163)
2051 Wireless Housing with Coplanar Platform
[Link] 69
Rosemount 2051 April 2013
5.66 (144)
3.85 (98) 5.20 (132)
4.36 (111)
Fieldbus
Display Cover
6.19
(157)
7.44 Terminal
HART Display
(189) Connections
Cover
Transmitter
Circuitry
70 [Link]
April 2013 Rosemount 2051
7.03
3/8–16 × 11/4 Bolts
(178)
for Mounting
to Transmitter
6.15
(156) 2.81
(71) 3.4 (85)
4.73
(120)
2-inch U-Bolt
for Pipe Mounting
PIPE MOUNTING
6.22
(158) 3.51
(89)
[Link] 71
Rosemount 2051 April 2013
5.66 (144)
3.85 (98) 5.20 (132)
4.36 (111)
Fieldbus
Display Cover
Terminal
HART Display
7.76 Connections
Cover
(197)
1
/2 - 14 NPT Flange Transmitter
Adapter (optional) Circuitry
Drain/
Vent Valve
1.626
(41,3)
2.13
1.10 (28) 3.40 (86) 1.05 (27)
(54)
Fieldbus
Display Cover
6.19
(157) HART Display
1 Cover
/2 - 14 NPT Terminal
Flange Connections Transmitter
Adapter Circuitry
Drain/ (optional)
Vent Valve
1.626
(71)
3.75 (95)
Max Open
2.126
1.05 3.50 1.10 (54)
(27) (89) (28) 6.20 (158) 2.70 (69)
Max Open Max Open
8.90 (226)
Max Open
Dimensions are in inches (millimeters).
72 [Link]
April 2013 Rosemount 2051
2.62
(67)
6.19
(157)
1.94
(49) 11.51
(292)
3.56 (90)
5.32 Max Open
(135) 4.85
(123)
3.50 1.10
(89) (28)
6.19 (157)
3.56 (90)
6.76 (172) MAX OPEN
1.10 (28)
3.50 (89)
2.62 (67)
0.93
(24)
[Link] 73
Rosemount 2051 April 2013
Fieldbus
Display Cover
HART Display
7.15 (182)
Cover
Terminal
Transmitter Connections
Circuitry
74 [Link]
April 2013 Rosemount 2051
Fieldbus
Display Cover
7.15
(182)
HART Display
Cover
Terminal
Connections
Transmitter
Circuitry
4.85 4.40
(123) (112)
6.25 (159)
Max Open
[Link] 75
Rosemount 2051 April 2013
5.16 (131)
1.99 (51)
2.81 (71)
6.21
(158)
3.49
(89)
4.72
(120)
6.90
(175)
76 [Link]
April 2013 Rosemount 2051
B
C
(1) The Pak-Lok Annubar model is available up to 600# ANSI (1,440 psig at 100 °F (99 bar at 38 °C)).
[Link] 77
Rosemount 2051 April 2013
78 [Link]
April 2013 Rosemount 2051
10.2
8.8 [223.46] [258.28]
6.2
[156.51]
5.3
[134.51]
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
[Link] 79
Rosemount 2051 April 2013
3.85 3.85
(98) (98)
E
D
Terminal
Connections
6.60
F (68)
E 7.02
(178)
8.12
(206)
Flushing Connection
Diaphragm Assembly and
Mounting Flange
Transmitter
Circuitry
B C
80 [Link]
April 2013 Rosemount 2051
Alarm(1): High
Software tag: (Blank)
[Link] 81
Rosemount 2051 April 2013
82 [Link]
April 2013 Rosemount 2051
[Link] 83
Rosemount 2051 Product Data Sheet
00813-0100-4101 Rev JA April 2013