0% found this document useful (0 votes)
47 views9 pages

Project #10

The document discusses key plants for a landscape design. It notes that trees like oak, maple, and pine provide shade and structure. Shrubs like hydrangea, rose, and lilac add color and interest. Perennials such as daylilies, hostas, and astilbes provide seasonal flowers and foliage.

Uploaded by

indyecrafts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views9 pages

Project #10

The document discusses key plants for a landscape design. It notes that trees like oak, maple, and pine provide shade and structure. Shrubs like hydrangea, rose, and lilac add color and interest. Perennials such as daylilies, hostas, and astilbes provide seasonal flowers and foliage.

Uploaded by

indyecrafts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Key Plan nts

St
w

Rd
ie
irv

y
Dr

la
Pa

Fa

rc
ury lin

Ba
Ln g
Rd
Pa
r ke
rC
re
As s

St
h

w
SITE le

ie
y

irv
Av

Fa
Dr e
ur
y
Ln
As
h le
PART OF LOT 21 y
Jo Av
.1
5 yc e
95 REGISTERED PLAN 203 e Dr
5.
52 St

Ct
5 .5
2
.5
4 9 .3
9 ur
.4 95 y

n
95 95
95
18.90 Ln

go
Ar
G
N44°46'00"W eo
rg

t
tS
e
St

Dr

ec
p
d

os
oo
7 2

e
1 5.

Pr
.4

Av
w
9
95 3

le
.5 5 7
.4 43 50 .7

nt
ap
95 95 95
. . 95
95

he
0

M
3 T
5. D

G
9 Ø
SOD
31
0.

REMOVE EXIST.

PROP. WOOD FENCE


FRAME SHED

. 36
95

59
SURVEYOR'S CERTIFICATE
.
.4
1
D
T 95
95 41
5. SOD 0Ø
9 46 .2 .6
5
5. 0
95 4
9
95
.8 I Have Reviewed The Plans For The Construction Of, ___ ______
70
PROP.

PROP. WOOD FENCE


.
95 ____ , And Have Prepared This Plan To Indicate The Compatibility
T

D
GARAGE Of The Proposal To Existing Adjacent Properties And Municipal
3
0.
Services. It Is My Belief That Adherence To The Proposed Grades
0
.7
LOT 5 95 As Shown Will Produce Adequate Surface Drainage And Proper
53
95. REGISTERED PLAN 878 Facility Of The Municipal Services Without Any Detrimental Effect
T SOD
SOD Ø
D To The Existing Drainage Patterns Of Adjacent Properties. I Can
41 .7
3
0. 95 Also Confirm That The Dwelling Height, Coverage & Setbacks Are
.5
5
SOLID LOT 6 Accurate.
95

FLUSH
HOARDING .70 SINGLE FAMILY
5 95 RESIDENTIAL
.5
95
.6
6 PROP.
9 95
.5
95 PAVERSTONE

FENCE & GATE


7
.7

PROP. WOOD
TERRACE

WINDOW WELL
95

PRECAST
AD
Lot Coverage Diagram 1:300

N44°14'00"E
0
LOT 4 96
.1
1
SINGLE FAMILY .1
96
RESIDENTIAL
PROP. DATE CHRIS BERESNIEWICZ
Lot Coverage PROP. SOD SOD PROP. 96
.1
2

.7
7
ASPHALT .9
6 ONTARIO LAND SURVEYOR
1-STOREY 95
TREE
95
House Footprint 151.75 sm
ADDITION 3R 95
. 76
.8
1 DRIVEWAY D
T
77 95 Ø The Undersigned Has Reviewed And Takes Responsibility For This
10
Detached Garage 42.36 sm 95
.
5.
78 PROP. 0.
96
.0
0 Design, And Has The Qualifications And Meets The Requirements Set
5.
71 9 3 Out In The Ontario Building Code To Be A Designer.

38.10
[Link] .8
Total Coverage 194.11 sm
9
4
PROP.
95
.7
5
95
.7
9
COV'D F.P 95
95
. 83
95
.9
6
95
. 99
Qualification Information Required Unless The Design Is
1
26.96% .7 WOOD
.8 Exempt Under Division C -[Link]. Of the 2012 ONTARIO Building Code.
95 FENCE
&
95 PORCH
Peter Giordano 25061

CONSTRUCTION MATERIAL
STORAGE AREA
GATE
2 3 2
.7 .7 1R 84 .9 097 Name Signature BCIN
95 95 . 4 95 .50.
95 5.
8
969
9 Registration Information Required Unless The Design Is
1R Exempt Under Division C -[Link]. Of the 2012 ONTARIO Building Code.

N44°14'00"E
DAVID W. SMALL DESIGNS INC. 29999
75 Firm Name BCIN
Underground Utilities: E-
10
0.
EXISTING
TR
1-STOREY 19
1 STOREY 1.
The Location Of Underground Services Shown BRICK DWELLING 5.
7 5 DWELLING TR
E-
10

On This Plan Is Only Approximate And Is For 9


No. 776
No. 782
Match Grades

1 STOREY
Planning And Design Purposes Only. This 2
.6 BRICK DWELLING
Information Must Not Be Assumed To Be 6 SOD

38.10
-9 No. 786
Complete Or Up-To-Date And An On-Site Locate D
SE FF 96.72
00
3:1 3:1 Must Be Ordered Prior To Any Excavation. David BF 94.12 RECONF. -9
7.
CL SE
Max Max W. Small Designs Inc. Accepts No Responsibility TOP OF ROOF 101.06
COV'D D
For Any Claims Or Losses Due To Improper Use
2.0% M Of This Information. 6 1R PORCH LINE OF
inimum
3 .7
inimum SWALE .8 95
ROOF O.H.
XXXXX 2.0% M 0 0 95

X XXXX
6.
XXXXX 9
XXXXX Notes:
Depth

7 7
.0 .7 7
.0
2 96 95 .8
96 . 76 95 5
95 .2
3R 96
Property

9 1
Gr a s s There Are To Be No Grad Changes Within 0.3m .9 .2
Limit

LINE OF FRONTAGE @ 7.5m = 18.9 1 95 96


0 .0
Of Common Property Lines LINE OF FRONT YARD SETBACK @ 7.5m
96
.0 96 5.
99
.9
4
AC
9 95 8 D
T EXIST. A/C &
1 Nov 17/23 Issued To Owner For Building Permit Application
Minimum Depth = 150mm The Existing Sanitary Lateral Must Be Inspected .00 9 5 .9
20
Ø GAS METER

96 0.
no. date revision / comment

HOARDING
Maximum Depth = 250mm at The property Line By Regional Inspector, And Average Grade Diagram - Detached Garage 1:150 SOD
EXIST.

SOLID
Televised By Regional Forces Prior To .1
9
9 0 96
Connection. A Lateral That Does Not Meet .9 .0 SHARED
Current Regional Standards Must Be
95 96
.2
3 Project:
1R ASPHALT .0
1
.1
3 96
Dissconnected At The Main. A Revision To The 6 8
.8
9 96 96
5. 97 95 .86 DRIVEWAY
Service Permit Drawings And Payment Of 3 9
95
.
Typical Swale Detail nts C
T 7 95

The Muise-Sidock Home


PROP. .9
Applicable Fees Is Required. 4 1Ø 95 .6
7
0. 95

CONSTRUCTION
PAVERSTONE
3

782 Ashley Avenue


WALKWAY 8
5.
Legend

ACCESS
Existing Services Must Be Disconnected At The .8
8 9 6 3
.7 .9 .0
9
8
95 95 95 96
Main By The Contractor 95
.4
5
SOD
.8
3R Main Level Entrance/Exit .53 95 02
Lot 5
.
All Water And Sanitary Main Taps Are To Be 95 96

Preformed By Region Of Halton Forces Only


3R Lower Level Entrance/Exit
18.90 Registered Plan 878

HOARDING
Contractor To Determine Existing Inverts And THERE WILL BE NO CHANGE TO
N44°46'00"W

FRAMED
Property Line THE EXISTING GAS AND HYDRO City of Burlington,
Report Any Discrepancies To The Engineer UTILITIES, OR THEIR CONNECTION PARCEL A
TO THE DWELLING AS PART OF
Regional Municipality of Halton
Existing To Be Removed THIS APPLICATION (1' RESERVE)
Contractor To Determine San. Inverts On Site (BY REGISTERED PLAN 878)
2
. 05 Existing Spot Elevation And Determine If San. Ejector Pump Is Required 4
X 1 02 .1
9
.2
7
9
Drawing:
95 95 .3 3
95 .4 . 48 53
95 95 95
.
102.05 X Proposed Spot Elevation Base Information: 5.
16 25 95
.5
9

Site Plan
-9 5. .3
7 2 7
TC -9 95 5.
4 3 3
TC - -9 5. .5 59
TC
-9 95 5.
Rainwater Downspouts TC BC TC
- -9
Base Information Taken From Plan Of Survey 5.
0 5
.1
4 TC
49
-9 5 27 5.
BY: Young & Young Surveying Inc. BC BC
-9
-9
5. -9
AC Air Conditioner BC BC
Dated: August 14, 2013
Solid Hoarding Location
Framed Hoarding
Lot 5
ASHLEY AVENUE
ESC Or Silt Fence Hoarding 1 91
.6
(FORMERLY ASHLY AVENUE BY REGISTERED PLAN 878) 1:150
Registered Plan 878 R
VE 64
T
. 14
21 .4
3 92
.4
Scale:

SP
2
City Of Burlington IN 94. 95 .
5.
3 95 T
AD Area Drain 95 9 V ER
Regional Municipality of Halton IN .5
7
Nov 2021
95
95
. 42 Date:
Denotes Coniferous Tree
(with trunk diameter) City Benchmark
C HM
0Ø To Remain Dwn by:
0.3 Elevations Are Geodetic And Are Referred To
The City Of Burlington Benchmark No. BM1066 23-2067
Denotes Deciduous Tree Having A Published Elevation Of 93.04 Metres Sewers Proj. no.:
0 ØD (with trunk diameter)
0.3 To Remain
Existing Sanitary Serer Will be Reused.
*TFW (Top Of Foundation Wall)
Denotes Tree Depth Of Sanitary Sewer Connection At The
C (with trunk diameter) Floor Sill Plate On Inside Face Of Foundation. Street Line To Be Confirmed In Field Prior To
0Ø Construction To Ensure Gravity Flow
0.3
To Be Removed - See Reduced Thickened Foundation Wall Detail
& Reverse Veneer Detail For Foundation Wall
Ledge Condition On Outside Face Of Foundation Top of Foundation Wall Condition 1:20
R# Denoted Replacement Tree Walls. Tree Protection:
Native Species Min 60mm - Extent Of Each Type To Be Determined By
Caliper For Deciduous And Contractor On Site During Construction Trees Within Tree Protection Zones Shall Be Protected By Means Of A "Tree Protection Barrier" Meeting The Following
IES 1.8m Height For Coniferous Site Data
PEC Specifications:
S
(SPECIES) Refers To Type of **U/F (Under Side of Footing)
A. The Required Barrier Is A 1.2 Metre (4ft) High Orange Plastic Web Snow Fencing On A 2'x4' Frame Should Be Used. Where Orange Plastic Web Lot Area 719.98 sm (0.071 ha)
Replacement Tree As Per FINISHED Zoning R2.3
Arborist Report - U/F Denotes Minimum Depth Of Under Side Snow Fencing Creates A Restriction To Sightlines, Page Wire Fencing With Reflective Tape Will Be Used.
FLOOR (FF) Fixed Grade 95.32
(R#) Refers To Replacement of Footing.
- Under Side of Footing May Differ B. A Modu-Loc Fence (Or Approved Equivalent) Will Be Acceptable As An Alternative To A. Above. Fence Must Be
Tree Number Corresponding
Properly Braced And Maintained For The Duration Of The Project.
w/ Arborist Report Depending On Basement Conditions. See Floor Area Existing Removed Proposed Total
Floor Plans And Elevations For Specific Ground Floor 107.71 sm 1159.4 sf 0.0 sm 0.0 sf 41.06 sm 442.0 sf 148.77 sm 1601.4 sf
Under Side Of Footing Conditions . C. Tree Protection Barriers Are To Be Erected Prior To The Commencement Of Any Construction Or Grading Activities On The Site And Are To Remain
Denotes Tree Number
# Corresponding w/ Arborist - Footings To Be Min 1.2m Below Grade In Place Throughout The Entire Duration Of The Project. The Barriers Shall Be Maintained Erect And In Good Repair Throughout The Duration Of
Construction Operations With Breaks And Unsupported Sections And Shall Be Removed Upon Completion Of Work.
(Includes 56.6 sf of Stairs)

Report Total Area 107.71 sm 1159.4 sf 0.0 sm 0.0 sf 41.06 sm 442.0 sf 148.77 sm 1601.4 sf
TOP OF GRADE D. All Supports And Bracing Used To Safely Secure The Barrier Should Be Located Outside The Tpz. All Supports And Bracing Should Minimize Basement 109.45 sm 1178.2 sf 0.0 sm 0.0 sf 41.06 sm 442.0 sf 150.52 sm 1620.2 sf
General Notes: Damage To Roots.
FOUNDATION
(Measured to Exterior Face of Basement Walls)
Finished Basement 79.78 sm 858.8 sf
E. Where Some Fill Or Excavated Material Must Be Temporarily Located Near A Tpz, A Wooden Barrier Or Modu-Loc Fence Must Be Used To Ensure
1. Do Not Scale Drawings WALL (TFW) No Material Enters The Tpz.
(Measured to Inside Face of Finished Basement Walls)
Interior Alterations 86.14 sm 927.2 sf
2. These Plans Are To Remain The Property Of The Designer And Must Be Returned Upon
Request. These Plans Must Not Be Used In Any Other Location Without The Written Approval Of F. Measurement And Payment Shall Be In Linear Meters Measured Along The Length Of The Barrier. Overlaps Shall Not Be Measured. Progress
Payments Shall Be Based On The Following Percentage Of The Contract Price: Lot Coverage
The Designer.
Proposed Footprint 21.08% 151.75 sm
3. All Works To Be In Accordance With The Ontario Building Code And All Code References Refer
To O.B.C. 2012 Division 'b'
TFW - Typ. Condition -
-
60% For Supply And Erection
25% For Maintenance
Proposed Detached Garage 5.88% 42.36 sm

(FLAT TOP WALL) - 15% Removal Total Proposed Coverage 26.96% 194.11 sm
Max Allowed Coverage 40.00% 287.99 sm

[Link]

You might also like