0% found this document useful (0 votes)
1K views1 page

3 Phase Induction Motor Test Certificate

1) This document is a routine test certificate for a 3 phase induction motor supplied to ORBIT DRIVE. 2) The motor has a power rating of 7.5 kW at 415 V, 50 Hz. Key test results like no load current, locked rotor current, and insulation resistance met specifications. 3) The motor passed high voltage, reduced voltage running up, and other routine tests as specified in IS/IEC60034, indicating it is fit for intended use.

Uploaded by

shelkeaba4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

3 Phase Induction Motor Test Certificate

1) This document is a routine test certificate for a 3 phase induction motor supplied to ORBIT DRIVE. 2) The motor has a power rating of 7.5 kW at 415 V, 50 Hz. Key test results like no load current, locked rotor current, and insulation resistance met specifications. 3) The motor passed high voltage, reduced voltage running up, and other routine tests as specified in IS/IEC60034, indicating it is fit for intended use.

Uploaded by

shelkeaba4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Routine Test Certificate

For 3 Phase Induction Motor

Customer ORBIT DRIVE


ORDER NO. & DATE /
Indent No & Date / Issue Date: 21/01/2023
Motor No. 7.50KNE4FLG Frame ND132M Excise No VLGM01549
Kilo Watt 7.5 Duty S1 [Link] F
Volts 415+-10% Freq 50+-5% Eff FL 88.7 IE2
Amps / Conn 13.8D Rating CONT
RPM 1455 Amb 50°C Gas Group
Bearing DE/ODE 6308ZZ/6208ZZ Mounting B5 Enclosure TEFC
Space Heater Deg of protn IP55 Type SCR
Thermistor
Resistance Between Terminal STATOR 1.09 Ohm at amb. 30°C
Test Volts Amps 1 Amps 2 Amps 3 Watts
No Load 415 8.0 8.0 8.0 692
Locked Rotor 135 32.2 32.2 32.2 3166
Insulation Resistance (Before & after HV test) Above 150 Megaohm
Reduced voltage running up test at 1/√3 rated voltage OK
High Voltage Test at 2000 V for 1 min OK
Open Circuit rotor volts ( For slipring motors only)
Other Details :
NL RPM 1517 50.6 Hzs
Remarks : IEC60034;IE2

Test witnessed by :

We certify this motor has been tested as per IS/IEC60034 and results found satisfactory
Certificate is electronically generated hence no signature is require
Quality Assurance
LT Motor Division
*Motor is tested under controlled conditions & at no [Link] data may differ at site due to improper connection, poor power quality & if tested with coupled condition.
Always read operation & maintenance manual carefully before installing the motor.

TESTED OK