0% found this document useful (0 votes)
22 views3 pages

IMPRIMIR

This document is a report template for testing the condition of grease in bearings using an SKF Grease Test Kit. It collects information about the application, machine, bearing, lubrication conditions, samples taken, and results of visual inspections, consistency testing, oil bleeding testing, and contamination testing. The inspector provides an interpretation of the test results and any necessary recommendations.

Uploaded by

clenilso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views3 pages

IMPRIMIR

This document is a report template for testing the condition of grease in bearings using an SKF Grease Test Kit. It collects information about the application, machine, bearing, lubrication conditions, samples taken, and results of visual inspections, consistency testing, oil bleeding testing, and contamination testing. The inspector provides an interpretation of the test results and any necessary recommendations.

Uploaded by

clenilso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Date: ........ /......... /.........

SKF Grease Test Kit TKGT 1 - Report Template


Application & lubrication conditions (Refer to chapter 3.1 in the instructions for use)

Application type:

Machine number
(bearing position):
Bearing type and ø With W33 design ø N/A
designation:
Bearing operating ø °C ø °F Ambient temperature: ø °C ø °F
temperature:
Rotational speed n [Link] value: dm= 0.5*(d+D)
(r/min): d: Inner bore diameter, mm
D: Outer ring outside diameter, mm
Load (C/P): ø unknown
C: Basic dynamic load rating, kN
P: Equivalent dynamic bearing load, kN
Special conditions: ø Vertical shaft ø Outer ring rotation ø Oscillating movements
ø Vibrations ø Standing still ø Shock loads
ø Others (decribe): ...............................................................................................................................
Sealing type: ø Mechanical seals ø Labyrinth seals ø Oil seals
ø Shields ø Sealed for life
ø Other (decribe): ................................................................................................................................
Ambient conditions: ø Dry ø Humid ø Dirty/dusty
ø Contaminants ø Other (describe): ...................................................................................

Current lubrication conditions

Grease in use ø unknown


(name):
Basic speciocations: NLGI Thickener Base oil
Class: type: type:
Relubrication ø unknown Relubrication quantity ø unknown
interval (hours): (grams):
Relubrication ø Manual ø Automatic lubricator ø Centralized lubrication system
method:
ø Other (describe): ..................................................................................................................................

Recommendation given by SKF LubeSelect ([Link]

Grease
(name):
Relubrication Quantity (grams)
interval (hours):

Notes:
...........................................................................................................................................................................

...........................................................................................................................................................................

...........................................................................................................................................................................
Machine number
(bearing position):

Nature of analysis:

ø Shelf life/Quality ø Routine control ø Damage


ø Grease performance ø Trend analysis ø Change of grease
ø Contamination expected ø Other reasons: .........................................................................................................

Collecting sample (Refer to chapter 3.2 in the instructions for use)

Sample name:
Date of sampling:
Date of last
relubrication:
Sample location: ø Bearing ø Bearing raceways ø Bearing cage ø Between roller elements

ø Seal ø Housing ø Other:: ..........................................................................


Bearing operating ø unknown
time (hours):

Testing (Refer to chapters 3.3 to 3.6 in the instructions for use)

Sample First visual inspection Consistency test Oil bleeding test Contamination test
(3.3) (3.4) (3.5) (3.6)
Fresh unused NLGI class:
(name): DAvFresh : .........&mm

....................... .......................................... SFresh : &&.........mm2


Used (name): NLGI class:
DAvUsed : &..........mm

....................... .......................................... SUsed : &.......&..mm2


Changes: NLGI difference:
%Diff :.........................

..........................................

Interpretation (Refer to chapter 3.7 & 4 in the instructions for use)

....................................................................................................................................................

....................................................................................................................................................

....................................................................................................................................................

Inspector /Technician:

The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted.
Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or
consequential arising out of use of the information contained herein.

SKF Maintenance Products


MP5366E-1 · 2009/11 · © SKF 2009
® SKF is a registered trademark of the SKF Group
[Link]
[Link]/lubrication
SKF Consistency test scale - TKGT 1

NLGI Grade
000
00
000
00
0
0
1
2
3
4
1
5

2
3
4
5

Printing tip:
For correct scaled print
always select
Page Scaling: None

The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts)
SKF Maintenance Products unless permission is granted. Every care has been taken to ensure the accuracy of the information contained
MP5366-2 · 2009/11 · © SKF 2009
in this publication but no liability can be accepted for any loss or damage whether direct, indirect or
® SKF is a registered trademark of the SKF Group
consequential arising out of the use of the information contained herein.