SCP02 pressure sensor
Device features
Pressure and temperature sensors
Small design
Stainless steel measuring cell
Stainless steel housing
Shock and vibration proof
High protection degree
E1 road approval
Substance temperature -40 to 150 °C
Up to 1000 bar
1 ms
Up to 36-V wiring systems
The SCP02 was designed specifically for the use in mo- An EDM hole has been added so that you get a precise,
bile working machines. The SCP02 has e1-approval and interference-free pressure measurement. This minimises
is manufactured with state of the art production methods the cavitation of air and dirt, thus preventing the meas-
according to ISO/TS 16949. uring cell from being influenced by pressure surges and
pressure peaks.
The shock and vibration resistance, the EMC characteris-
tics, the power supply as well as the extended tempera-
Typical application range
ture range all were designed for this application type.
Mobile hydraulics
The SCP02 is suitable for quick control solutions because Transport vehicles
of its fast response speed. Conveyor vehicles
The compact stainless steel housing with the plastic con- Commercial vehicles
nector allows for use in harsh environmental conditions Automotive technology
such as those in mobile hydraulics. Brake systems
Oil pressure
The components which come into contact with the sub-
Test equipment and technology
stance are made from stainless steel (1.4548). This fea-
Gearbox control
ture, combined with the welded, thin-layer measuring cell,
ensures optimal compatibility with the substance.
16 Catalogue 4083/UK
SCP02 pressure sensor
Technical data
Pressure and temperature sensors
SCP02- 010 025 040 060 100 160 250 400 600 1000
Pressure range Pn 10 25 40 60 100 160 250 400 600 1000
relative 0... (bar)
Overload pressure*
2 x Pn 1.5 x Pn
Pmax relative (bar)
Burst pressure**
4 x Pn 2.5 x Pn
Pburst relative (bar)
* DIN EN 60770-1
** DIN 16086
General Ambient conditions
Response time ≤1 ms Ambient temperature range -40...+125 °C
Long-term stability < 0.2 % FS / a Fluid temperature range -40...+150 °C
Load change > 100 million Storage temperature -40...+125 °C
Weight Approx. 55 g Vibration resistance IEC 60068-2-6: 20 g
MTTFd > 100 years Shock resistance IEC 60068-2-27: 500 g
Accuracy Electrical protection
Linearity, pressure hysteresis ≤0.5 %FS Short circuit, signal against GND/0V and protection against
and reproducibility polarity reversal (not with ratiometric output)
Complete accuracy ≤1.0 %FS (0...+80 °C) EM compatibility
≤1.5 %FS (-25...+100 °C) Disturbance emissions EN 61000-6-3
≤2.5 %FS (-40...+125 °C)
Resistance to interference EN 61000-6-2
Temperature coefficient
Process connection
Zero point Max. ≤± 0.2 %FS/10 K
Eroding milling 0.6 mm
Output range Max. ≤± 0.2 %FS/10 K
Tightening torque Max. 35 Nm
Material
Housing EN/DIN 1.4301
Electrical plug Plastic PBT-GF30
Ultradur B4300 G6 black
Process connection Seal Parts in contact with Max. pressure range Pn
substances
G1/4A BSPP; DIN 3852 T11, Form E Sealing ring DIN 3869-14-FKM EN/DIN 1.4548 / FKM 1000 bar
SAE-4: 7/16-20 UNF O-ring O-ring FKM EN/DIN 1.4548 / FKM 400 bar
SAE 6: 9/16-18 UNF O-ring O-ring FKM EN/DIN 1.4548 / FKM 400 bar
G1/4 DIN ISO 228-1 O-ring O-ring FKM EN/DIN 1.4548 / FKM 600 bar
1/4 NPT EN/DIN 1.4548 600 bar
Output signal 2-wire 0...5 V; 1...6 V 0...10 V 0.5...4.5 V
P signal 4...20 mA 0.5...4.5 V nom. ratiometric
Auxiliary power V+ +9...36 VDC +9...36 VDC +14...36 VDC 5V
Load Ω (Ohm) ≥50...≤500 Ω ≥10 kΩ ≥10 kΩ ≥10 kΩ
(V+ - 9 V) / 20 mA
17 Catalogue 4083/UK
SCP02 pressure sensor
Pin assignment
Pressure and temperature sensors
AMP Superseal 1.5
SCP02-xxx-xx-0A
2-wire 0...5 V; 1...6 V; 0.5...4.5 V
PIN
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
1 P-signal 0 V / GND 0 V / GND
2 n.c.* P-signal P-signal
3 V+ V+ V+
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP67
DT04-4P
SCP02-xxx-xx-0D
2-wire 0...5 V; 1...6 V; 0.5...4.5 V
PIN
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
1 V+ V+ V+
2 P-signal 0 V / GND 0 V / GND
3 n.c.* P-signal P-signal
4 n.c.* n.c.* n.c.*
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP67
DT04-3P
SCP02-xxx-xx-0E
2-wire 0...5 V; 1...6 V; 0.5...4.5 V
PIN
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
A V+ V+ V+
B n.c.* P-signal P-signal
C P-signal 0 V / GND 0 V / GND
Mate- Plastic PBT-GF30 Ultradur B4300 G6 black
rial
Protection class IP67
2 m fixed cable
SCP02-xxx-xx-00
2-wire 0...5 V; 1...6 V 0.5...4.5 V
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
bn V+ V+ V+
black n.c.* P-signal P-signal
blue P signal 0 V / GND 0 V / GND
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP69k
bn = brown-braun / bk = black-schwarz / bu = blue-blau
*n.c. = do not connect
18 Catalogue 4083/UK
SCP02 pressure sensor
Pin assignment
Pressure and temperature sensors
M12x1
SCP02-xxx-xx-x5
2-wire 0...5 V; 1...6 V 0.5...4.5V ratiometric CAN-Assignment
PIN
4...20 mA 0.5...4.5 V nom.; 0...10 V
1 V+ V+ V+ CAN shield, PE
2 P-signal P-signal P-signal +UB, +24 VDC
3 n.c.* 0 V / GND 0 V / GND GND, 0 V
4 n.c.* n.c.* n.c.* CAN_H, CAN+
5 n.c.* n.c.* n.c.* CAN_L, CAN-
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP67
*n.c. = do not connect
SCP02-xxx-xx-0A SCP02-xxx-xx-0D SCP02-xxx-xx-0E
AMP Superseal DT04-4P DT04-3P
SCP02-xxx-xx-05 SCP02-xxx-xx-00
M12x1 Stationary cable (2 m)
19 Catalogue 4083/UK
SCP02 pressure sensor
SCP02-xxx-x4-0x SCP02-xxx-x8-0x SCP02-xxx-x5-0x
Pressure and temperature sensors
G 1/4, DIN 3852 T 11 (Form E) G1/4 O-ring 1/4 NPT
X1) = ED-seal X1) = O-ring
SCP02-xxx-x7-0x SCP02-xxx-x6-0x
SAE 04 - O-ring SAE 06 - O-ring
X1) = O-ring 8.92x1.83 X1) = O-ring 11.89x1.98
SCP02-xxx-xx-0x
M12x1
S1) = SW22
20 Catalogue 4083/UK
SCP02 pressure sensor
Order code Connection cable and single plug
Pressure and temperature sensors
Pressure sensor SCP02 SCP02-xxxx-xx-0x Connection cable, assembled SCK-400-xx-xx
Pressure range (open cable end)
0…10 bar 010
0…25 bar 025 Cable length (m)
0…40 bar 040 2m 02
0…60 bar 060 5m 05
0…100 bar 100 10 m 10
0…160 bar 160
0…250 bar 250 Connecting plug
0…400 bar 400 M12 cable jack; straight 45
0…600 bar 600 M12 cable jack; 90° angled 55
0…1000 bar 1000
Single connector
Output signal M12 cable jack; straight SCK-145
4...20 mA (2-wire) 3 M12 cable jack; 90° angled SCK-155
4...20 mA (3-wire) 2
0...10 V 4
0...5 V A Order example
1...6 V B
0.5...4.5 V (ratiometric) R SCP02-400-34-05
0.5...4.5 V (nom.) S
Single sensor
CAN K
Pressure range 400 bar
Process connection Output signal 4 to 20 mA (2-wire)
G1/4 BSPP 4 G1/4 BSPP
1/4 NPT (Pn max. = 600 bar) 5 M12 connecting plug 5-pole
9/16-18 UNF, SAE 6 O-ring (Pn max. = 400 bar) 6
7/16-20 UNF SAE-4 O-ring (Pn max. = 400 bar) 7
G1/4 O-ring (Pn max. = 600 bar) 8
Connecting plug
Stationary cable 1 m 0
Circular connector M12x1 5-pole 5
Device plug AMP Superseal A
Device plug DT04 4-pole D
Device plug DT04 3 pole E
21 Catalogue 4083/UK