0% found this document useful (0 votes)
78 views6 pages

Residential Building Plan for Maskara

The document provides details of a proposed residential building to be constructed in Gopalpur East, Motihari, Bihar, India. It includes details of the land ownership, building plans showing dimensions and layouts, and schedules of openings. Reinforcement details of structural elements like roof slabs are also shown.

Uploaded by

nadimalam78692
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views6 pages

Residential Building Plan for Maskara

The document provides details of a proposed residential building to be constructed in Gopalpur East, Motihari, Bihar, India. It includes details of the land ownership, building plans showing dimensions and layouts, and schedules of openings. Reinforcement details of structural elements like roof slabs are also shown.

Uploaded by

nadimalam78692
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PROPOSED RESIDENTIAL BUILDING TO BE BUILT BY :-

Mr.-SUNIL KUMAR MASKARA, S/O- [Link] MASKARA


AT-MOH. :-GOPALPUR EAST, MOTIHARI, WARD NO:-40
THANA NO. :- 169, TAUJI :-1310, KHATA NO. :-2
KHESRA NO.-236, DISTT :- EAST CHAMPARAN, BIHAR.
HOLDING NO :-19 B SCALE :- 1"= 8'

5"[0.76]

[0.76]
2'-6"

2'-6"
[0.13]

[0.13]
5"
[2.90]

[2.90]
9'-6"

9'-6"
[0.13]

[0.13]
5"

5"
32'-9"
[9.98]

[2.90]

[2.90]
9'-6"

9'-6"
[0.13]

[0.13]
5"

5"
[3.05]

[3.05]
10'

10'
[0.91]

[0.91]
3'

P.L.

3'
P.L.

G.L. G.L.
FRONT ELEVATION SIDE ELEVATION
10" 2' 10" 5" 5" 10" 10" 10" 5' L 12 MM THICK CP
3' 3' 3'
GAS PIPE L/4 L/2 L/4 8 MM DIA WITH NEAT
10"
10"
S. PIT
DISTRBUTION
SCHEDULE OF OPENINGS. CEMENT
3'-8" A B TOR BAR 7" C/C. PUNNIGG
l/4

10" S.N. DOORS DIMENSIONS


10"
PLAN 3'-6"X7'-00"
10 MM DIA MAIN 1. D (1.09MX2.13M)
4" RCC COVER SLAB TOR BAR 5" C/C. 3'-0"x7'-00"
X 2. D1
l/2

1'
(.9mx2.13m)
BRICK
l

2' 2'-6"x7'-00"
3. D2 (.75MX2.13M) WALL
5' 10' l= LONG SPAN
4. 5'-0"x4'-6"
l/4

6"
L= SHORT SPAN W (1.5MX1.4M) 3" PCC
5. 3'-0"x4'-6" BFS
PLAN SHOWING BOTTOM REINFORCEMENT W1 (.9MX1.4M)
DETAILS OF ROOF SLAB 2'-0"x1'-6"
SECTION ON AB 6. V (.6X.49M)
A 27'-3" 27'-3"
[8.29] A [8.29]
W W
W W
DETAILS OF SEPTIC TANK AND SOAKPIT
STAIR V2

6'0"X13'6" STAIR
(1.8MX4.11M) 6'0"X13'6" R.C.C SLAB V1

(1.8MX4.11M)
BY PASS
BED ROOM BED ROOM
9'0"X13'6" 10'0"X13'6"

100
COARSE SAND
(2.74MX4.11M) (3.05MX4.11M)

100
GRAVEL

100
BOULDER
28'-11"
[8.81]

28'-11"
[8.81]

1500
D
D D D 100 MM DIA PILE

PARKING TOILET
SECTION AT-A A
57.27 SQM 6'0"X5'0"
(1.83MX1.5M)
0.5M
DINING D2
A

0.5M
19'6"X13'4"

2M
(5.93MX4.06M) D1
KITCHEN
2M
6'0"X7'11"
(1.83MX2.41M) DET. OF RECHARGEABLE BORE WELL

W1 W1
27'-11" W1 W
27'-11"
W1

A [8.50] [8.50]
GROUND FLOOR PLAN
A
FIRST & SECOND FLOOR PLAN

BEAM SIZE
10"x10"
(.24MX.24M)
4 NOS 10 MM Ø TMT BAR 2#12 2#12
(2 TOP + 2 BOTTOM) Extra 2#12TH Extra

(.12M)5"

(.24M)10"
3#12
(.24M)10"
#6@ #6@ #6@
TYPICAL DESIGN OF LINTEL BEAM 100 150 100 (.12M)5"
TYPICAL ROOF BEAM LINTEL OVER 10" WALL
TOTAL PLOT AREA = 109. 72 SQM
GROUND FLOOR AREA = 16.79 SQM
FIRST FLOOR AREA = 74.06 SQM
BOUNDARY DETAILS
SECOND FLOOR AREA = 74.06 SQM
N:- 8'0"(2.44M) W ROAD
TOTAL BUILT UP AREA =164.91 SQM
PARKING AREA = 57.27 SQM (34.72%) S:- 8'0"(2.44M) W ROAD
F.A.R. =1.5 E:- MADAN KUMAR MISHRA
BUILDING HEIGHT = 10.0 METER W:- 12'0"(3.66M) W ROAD
RAKAWA = 2.7 DISMAL
GREEN AREA (PLANTATION)=12.60 SQM(11.48%)

A ROAD
TOWARD DHAK

RULHI ROAD
CHHATUNI GOLMBER

N.H.28 A BYPASS CHOWK

TOWARDS BETTIAH TOWARDS MUZAFFARPUR


MOTIJHIL

KACHHARI RAILWAY BRIDGE


PROPOSED CONSTRUCTION
MINA BAZAR GOLMBER
GALI
GALI

TOWARDS BETTIAH ROAD ROAD 12'0" W


ROAD 12'0" W

MANDIR

MOTIHARI RAILWAY STASION BALUA GOLMBER

TOWARDS BETTIAH ROAD CHANDMARI--BALUA ROAD


RAGHUNATHPUR ROAD

[Link] VERMA GALI

TOWARDS ARERAJ

LOCATION PLAN
NOT TO SCALE
[0.76]
2'-6"
[0.13]
5" th.
27'-3" roof slab
[8.29]

5"
2'-6" Parapet wall

[2.90]
R.c.c. 6" R.c.c. 6" R.c.c. 6" R.c.c. 6"

9'-6"
TERRACE th. lintel. th. lintel. th. lintel. th. lintel.

[2.13]

[0.13]
7'

5"
28'-11"
[8.81]

32'-9"
[9.98]

[2.90]
R.c.c. 6" R.c.c. 6" R.c.c. 6" R.c.c. 6"

9'-6"
th. lintel. th. lintel. th. lintel. th. lintel.

[2.13]
TERRACE

[0.13]
7'

5"
SLOPE
SL
OP
SLOPE

E
TERRACE B

[3.05]
R.c.c. 6" R.c.c. 6" R.c.c. 6" R.c.c. 6"
PE

10'
th. lintel. th. lintel. th. lintel. th. lintel.
LO

[2.13]
S

7'

[0.91]
A 27'-11"
[8.50]

3'
TERRECE FLOOR PLAN

first class marble flooring over 6"


dry rammed khoa, over 3" b/f soling
section A-A
P.L
10"X12"(.24MX.3M) RCC PLINTH BEAM
12 MM ROD WITH 8 MM RING
INLET 12 MM ROD WITH 8 MM RING

(.9M)3'-0"
12 MM ROD WITH 8 MM RING
10"X12"(.24MX.3M) RCC PLINTH BEAM
PLAN 12 MM ROD WITH 8 MM RING
G.L 12 MM ROD WITH 8 MM RING
CI MH COVER
RC SLAB
EARTH QUAKE SAFETY MEASURES
(.9M)3'

G.L
PROVIDE- AIR VENT PIPE
R.C. holed
slab 8 MM RING @ 6" C/C
1- R.C.C. BAND AT GL. , PL. LL. AND RL. Inlet
SLOP 1:50

Jhama Brick Ballast or


2- L OR T BEAM AT ROOF LVL. bumt Clinker 6mm Size
3- COLUMN / STIFFNER AT JUNCTION Jhama Brick Ballast or
Quarry Spalls
10 MM RING
4- MINIMUM 4 -12Ø BAR IN COLUMN OR STIFFNER 10 MM RING
Honey Combed
5- EXPENSION JOINT AT EVERY 45 M. Brick Work in C.M 1:6 BORE WELL BRICK WORK 3"
6- U OR L HOOK IN REINFORCEMENT SAND FILL 3"
(1.2M)4'
7-TIE BEAM FOR INCLIND STRUCTURE
8- OTHER SAFETY MEASURES AS / I.S. 1456 SECTION DOUBLE MESH FOOTING

RAIN WATER HARVESTING


27'
SPECIFICATION [8.23]
1. FOUNDATION 1:1.5:3 ISOLATED FOOTING FOUNDATION
2. PLINTH AND FIRST CLASS B/W IN CM 1:8 SUPER

5' [1.22]
REAR SET

4'
STRUCTURE 3" THICK CC [Link] D.P.C WITH D.P.C POWDER
3. FLOORING 1" MOSAIC FLOORING OVER 6"DRK BACK 1.2 M

[1.52]
4. LINTEL 6" R.C.C LINTEL AND BAND OVER ALL WALL
5. ROOFING 4.5" R.C.C SLAB AND BEAM 1:1.5:3 ROOF GREEN AREA (PLANTATION) 5'0" W
N
TILES OVER R.C.C SLAB
6. WOODWORK SAL WOOD CHAUKHAT 4"X 3" SIZE AND

M) WIDE ROAD

8'-0"(2.44 M) WIDE ROAD


1.25" THICK SHUTTERS DOORS AND WINDOWS
7. FINISHING TWO COATS WHITE WASHING OVER
1/4"CEMENT PLASTER 1:4 IN CEILING AND
1/2" CEMENT PLASTER 1:6 BOTH SIDES OF WALLS
8. SANITATION 1. POWER DRIVEN TUBE WELL

8'-0"(2.44 42'-11"
[13.08]
2. PROVISION OF SEPTIC TANK WITH SOAK PIT AS

28'-11"
PER DETAILED DRAWING & 6" X6" PUCCA DRAIN

[8.81]
ALL SIDE OF WALLS
9. EARTHQUAKE RESISTANT RCC FRAMED STRUCTURE

RECHARGE BORE

[1.52]
ST&SP

5'
FRONT SET BACK 1.5 M
28'
[8.54]
12'-0"(3.66 M) WIDE ROAD

SITE PLAN

(.3M)12"
l/4
L/4 L/4 L/4
(.3M)12"

(.24M)10"
125C/C 175C/C 125C/C 125C/C
175C/C 125C/C

(.24M)10"
Applicant's Signature

Engineer's Signature Direction

E SE

E
N

S
N

S
W

W
N
W

riser (.17M)7"

thread(.24M) 10"

riser (.17M)7"

P.L.
Approved By
G.L.
section b-b
first class marble flooring over 6"
dry rammed khoa, over 3" b/f soling

You might also like