The document provides guidelines for testing and troubleshooting REVConnect plugs and jacks. It details the product specifications of REVConnect components and describes procedures for testing permanent links and channels using standard test equipment and adapters. Diagrams illustrate the testing configurations.

Uploaded by

marioarmenta72
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views1 page

REVConnect Testing and Troubleshooting Guidelines

The document provides guidelines for testing and troubleshooting REVConnect plugs and jacks. It details the product specifications of REVConnect components and describes procedures for testing permanent links and channels using standard test equipment and adapters. Diagrams illustrate the testing configurations.

Uploaded by

marioarmenta72
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

REVConnect Testing and

Troubleshooting Guidelines
Best practices for installing REVConnect plugs and jacks

REVConnect product facts:


• Component compliance to standard (ISO/IEC60603-7, ANSI/TIA-568-C.2 and ISO/IEC 11801 AMD 2)
• UL Listed
• 100% factory tested
• The jack and plug main body is specified for over 750 cycles (typically greater than 1,000 cycles)
• The terminated core is typically greater than 1,000 cycles

Testing Permanent Link Testing Channel


Follow standard test procedures from the Copper Structured Cabling Design Guide

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX

10 GX 10 GX

10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
10 GX 10 GX
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX

10 GX 10 GX

10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX 10 GX

10 GX 10 GX
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Testing Jack to Jack Testing Plug to Jack


Requires main and remote field Requires main and remote field
tester, permanent link adapter (x2) tester, permanent link adapter
and the actual permanent link being (x2), Belden coupler test adapter
tested. AX104552 and the actual
permanent link being tested.

1 Install the tester and the 1 Install the tester and the
remote unit on both sides of remote unit on both sides of
the permanent link as shown the permanent link as shown
in the figure. in the figure.

2 Select the cable type to be 2 Select the cable type to be


tested (Cat 5e, Cat 6 or tested (Cat 5e, Cat 6 or
Cat 6A). Cat 6A).

3 Select the “permanent link” 3 Select the “permanent link”


limit with the appropriate limit with the appropriate
category and standards category and standards
(ISO or TIA). (ISO or TIA).

4 Test all permanent links. 4 Test all permanent links.

© 2017 Belden Inc.

Our End-to-End Expertise • Your End-to-End Solution