TPS31
THREE POWER SUPPLY MODULE
USER MANUAL
Chinese trademark
English trademark
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road, Zhengzhou, Henan Province, China
Tel: +86-371-67988888/67981888/67992951
+86-371-67981000(overseas)
Fax: +86-371-67992952
Email: sales@[Link]
Web: [Link]
[Link]
All rights reserved. No part of this publication may be reproduced in any material form (including
photocopying or storing in any medium by electronic means or other) without the written permission of
the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication
should be addressed to Smartgen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective
companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.
Table 1 Version History
Date Version Content
2021-11-20 1.0 Original release.
2022-04-14 1.1 Modify the storage temperature from 80 ˚C to 70 ˚C.
TPS31 Three Power Supply Module User Manual Page 2 of 10
Table 2 Notation Clarification
SIGN INSTRUCTION
Highlights an essential element of a procedure to ensure correctness.
NOTE
Indicates a procedure or practice, which, if not strictly observed, could result in
CAUTION! damage or destruction of equipment.
Indicates error operation may cause death, serious injury and significant
WARNING! property damage.
TPS31 Three Power Supply Module User Manual Page 3 of 10
CONTENT
1 OVERVIEW ......................................................................................................................................................5
2 PERFORMANCE AND CHARACTERISTICS ...................................................................................................5
3 SPECIFICATION ..............................................................................................................................................5
4 INDICATOR STATUS.......................................................................................................................................6
5 PARAMETERS LIST ........................................................................................................................................7
6 CONTROLLER TERMINAL DESCRIPTION .....................................................................................................8
7 WORKING MODE DESCRIPTION....................................................................................................................8
8 INTERNAL LAYOUT AND INSTALLATION WAY ...........................................................................................9
8.1 OVERALL DIMENSION.............................................................................................................................9
8.2 INTERNAL TRANSFER SCHEMATIC DIAGRAM .....................................................................................9
8.3 INSTALLATION WAY ............................................................................................................................ 10
TPS31 Three Power Supply Module User Manual Page 4 of 10
1 OVERVIEW
TPS31 Three Power Supply Module is composed of microprocessor as the core, providing three
selective AC power output, which can precisely detect 3-way voltage and make accurate judgment and
control output for voltage abnormal situations (over voltage, under voltage).
2 PERFORMANCE AND CHARACTERISTICS
——System type is 3-way single phase AC power;
——Intelligent and precise MCU monitoring and control;
——Two working mode: mutual backup and power supply by priority;
——Measure 3-way input voltage and load voltage;
——Over/under voltage detection function, over/under voltage threshold can be set (via PC
software);
——Transfer time<60ms;
——LED can intuitively indicate 3-way input voltage status and output voltage status;
——Can be used for 3-way or 2-way power input;
——3-way independent switch power supply is adopted internally;
——3-way N wire isolated design;
——Guide rail installation and screw installation;
——Modular structure design, pluggable terminal, compact structure and easy mounting.
3 SPECIFICATION
Table 2 Technical Parameters
Item Content
3-way AC Voltage IN AC(90~305)V
Overall Consumption ≤4.8W
Max. Output Current 12A
Rated Power 50/60 Hz
SmartGen special interface for program upgrade and module parameter
LINK
configuration.
Overall Dimension (LxWxH) 115.5mmx 102mmx72. 5mm
Working Temperature (-40~+70)˚C
Working Humidity (20~93)%RH
Storage Temperature (-40~+70)˚C
Weight 0.4 kg
TPS31 Three Power Supply Module User Manual Page 5 of 10
4 INDICATOR STATUS
Fig.1 Mask Drawing
Table 3 Indicator Description
Status Description
S1 blackout, green indicator extinguishes;
S1 Power Status Indicator S1 normal, green indicator illuminates;
S1 abnormal, green indicator flashes.
S2 blackout, green indicator extinguishes;
S2 Power Status Indicator S2 normal, green indicator illuminates;
S2 abnormal, green indicator flashes.
S3 blackout, green indicator extinguishes;
S3 Power Status Indicator S3 normal, green indicator illuminates;
S3 abnormal, green indicator flashes.
Output blackout, green indicator extinguishes;
Output Power Status Indicator Output normal, green indicator illuminates;
Output abnormal, green indicator flashes.
S1 outputs and output blackout, red indicator flashes;
S2 outputs and output blackout, red indicator flashes;
Alarm Status Indicator
S3 outputs and output blackout, red indicator flashes;
S1, S2, S3 inactive but output voltage, red indicator flashes.
TPS31 Three Power Supply Module User Manual Page 6 of 10
5 PARAMETERS LIST
LINK interface is used for connecting upper computer via SG72A to configure parameters.
Table 4 Fixed Parameters
No. Name Range Default Description
Baud rate: 9600bps
1 Module Address 1-254 1 Stop bit: 1-bit
Parity bit: None
0: Mutual backup
1: Power supply by priority (S1>S2>S3)
2 Working Mode 0-1 0
Refer to Table 6 Working Mode
Description.
4 Rated Voltage (1-600)V 220V Rated voltage value of AC system.
Voltage upper limit value, abnormal when
5 Overvoltage Threshold (0-200)% 130%
greater than the value.
Overvoltage Return Voltage upper limit return value, normal
6 (0-200)% 125%
Threshold when less than the value.
Voltage lower limit value, abnormal when
7 Undervoltage Threshold (0-200)% 75%
less than the value.
Undervoltage Return Voltage lower limit return value, normal
8 (0-200)% 80%
Threshold when greater than the value.
TPS31 Three Power Supply Module User Manual Page 7 of 10
6 CONTROLLER TERMINAL DESCRIPTION
Fig.2 Terminal Definition
Table 5 Terminal Description
No. Name Description Remark
1 S1 Power L Phase
S1
2 S1 Power N Phase
3 S2 Power L Phase Input voltage 90-305VAC, frequency
S2
4 S2 Power N Phase 50/60Hz.
5 S3 Power L Phase
S3
6 S3 Power N Phase
7 Relay volts-free output, capacity is
ALARM Alarm Output
8 250V/5A.
9
Output L Phase
10
OUTPUT Max. output current is 12A.
11
Output N Phase
12
7 WORKING MODE DESCRIPTION
Table 6 Working Mode Description
Working Mode Description
It outputs when any one power is normal, only transfer
Mutual Backup
to other normal powers when this power is abnormal.
Power with higher priority will supply first. 3-way power
Power Supply by Priority (S1>S2>S3)
priority sequence is S1>S2>S3.
TPS31 Three Power Supply Module User Manual Page 8 of 10
8 INTERNAL LAYOUT AND INSTALLATION WAY
8.1 OVERALL DIMENSION
Unit: mm
Fig.3 Overall Dimension
8.2 INTERNAL TRANSFER SCHEMATIC DIAGRAM
Fig.4 Internal Transfer Schematic Diagram
TPS31 Three Power Supply Module User Manual Page 9 of 10
8.3 INSTALLATION WAY
The module can be installed with 35mm guide rail or M4 screw.
Fig.5 Guide Rail Installation
Fig.6 Screw Installation