0% found this document useful (0 votes)
50 views5 pages

TechnicalData EHSF

The document describes a high capacity water heater with a spiral flat heating coil. It has maximum heat exchange and storage volume available. The patented coil design improves performance, hygiene and efficiency compared to conventional heating coils.

Uploaded by

rachman hardian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views5 pages

TechnicalData EHSF

The document describes a high capacity water heater with a spiral flat heating coil. It has maximum heat exchange and storage volume available. The patented coil design improves performance, hygiene and efficiency compared to conventional heating coils.

Uploaded by

rachman hardian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Model EHSF: High Capacity Water Heater “The Green Calorifiers”

with Spiral Flat Heating Coil Enameling Lining Copper Lining Solvents

50 - 1,000 kW for water / water operation

Description

The ECOTHERM's new patented high-performance spiral coil has a


maximum heat exchange area in the cold water zone or in the desired
temperature zone due to its design and horizontal installation.

• Storage water heater made of stainless steel duplex / V4A with patented
high-performance flat heating coil welded at the bottom of the tank.

• Optimal performance and layering, almost 100% storage volume avail-


able, bath pickled, low maintenance, improved hygiene, flange DN 200
(and DN100 up 500 liter) at front for cleaning purpose or for mounting an
additional heat exchanger or screw-in heating element, sleeve 6/4“ for
screw-in heating element in the upper third, sleeves ½“ for thermom-
eters and temperature sensors, cold water connection at the front, hot
water outlet at the center top.

• Fibre-fleece insulation of storage tank with robust outer sheath made


of PP (RAL7037, dusty grey), patented aluminum closure strips and
self-fixing closure caps, quick and easy installation, 80mm insulation up
to 1,000 litres and 100mm above. 100% recyclable, fire protection class
B2 (B1 upon request)

• Production by TÜV certified welding company according to HP-0 and ISO


3834-2, approval to SVGW and certified according to ISO 9001: 2015.

EHSF 2000L • Simple installation and short mounting time due to pre-assembled units.

• Maximum pressure/testing pressure: secondary 6/9bar; primary 3/6bar

➔ Heating Water
Supply

➔ Heating Water
Return

ECOTHERM
Flat Spiral Heating Coil Flat Spiral Heating Coil

Plastic spacing guide with • avoids damage of the passive layer


KTW certification
• floated mounting of the heat exchanger
Metal framing profile - no forces transfered to the tank shell
Patented Spiral Flat Heating Coil
Conventional heating coils ECOTHERM Spiral Flat Heating Coils
Conventional heat exchangers are always in mixing tem- The patented spiral heating coil is mounted horizontally at the
perature zones from 10°C to 60°C and thus have a reduced bottom of the storage tank. It is 100% in the cold water zone,
heat transfer rate. During the heating phase heating coils respectively only in one temperature zone.
produce circulations in the storage tank and need more pri- The installation directly above the tank bottom and the
mary energy. The available standby volume is usually only low height (13cm) allow an almost complete heating of
about 70% of the capacity of the storage tank. the storage tank.

• Up to 30% reduced effective volume & • The special construction of the register ensures:
risk of legionella • High standby volume (97% of the tank capacity)
• Reduced power consumption and poor • Hygienic water
heat layering • High efficiency due to efficient heat transfer
• Limited heat exchanger surfaces and reduced • Optimized heat layering
installation options • Primary energy savings
• Increased primary energy consumption

Conventional heating coils ECOTHERM Spiral Flat Heating Coils

▲ ▲
97%
Standby volume
50 %


50 %

▼ 3%
▼ Mixing water area
▲ and “dead” volume

• 50% Standby volume • 97% Standby volume


• 50% Mixing water area and “dead” volume • 3% Mixing water area and “dead” volume
Type: EHSF
Performance Data
temperature primary temperature primary temperature primary
75°C - 55°C 85°C - 65°C 60°C - 55°C

temperature secondary temperature secondary temperature secondary


20°C - 60°C 20°C - 60°C 20°C - 55°C

continuous hot continuous hot continuous hot


One heating coil Type
volume capacity
water
capacity
water
capacity
water
[l] [kW] [kW] [kW]
output [l/h] output [l/h] output [l/h]

EHSF-400-2,5 400 54 1161 77 1655 35 752

EHSF-630-3 630 64 1376 92 1978 42 903

EHSF-800-4,2 800 90 1935 129 2773 59 1268

EHSF-1000-5,5 1000 117 2515 169 3633 77 1655

EHSF-1250-7 1250 149 3203 215 4622 98 2107

EHSF-1500-9,4 1500 200 4299 288 6191 131 2816

EHSF-2000-11,2 2000 238 5116 344 7395 156 3353

EHSF-3000-13,2 3000 281 6040 405 8706 183 3934

EHSF-4000-15,3 4000 325 6986 469 10082 213 4579

temperature primary temperature primary temperature primary


75°C - 55°C 85°C - 65°C 60°C - 55°C

temperature secondary temperature secondary temperature secondary


20°C - 60°C 20°C - 60°C 20°C - 55°C

continuous hot continuous hot continuous hot


volume capacity capacity capacity
Type water water water
Two heating coils [l] [kW]
output [l/h]
[kW]
output [l/h]
[kW]
output [l/h]

EHSF-400-5,1 400 109 2343 157 3375 71 1526

EHSF-630-6,1 630 130 2794 187 4020 85 1827

EHSF-800-8,4 800 179 3848 258 5546 117 2515

EHSF-1000-11 1000 234 5030 337 7244 153 3289

EHSF-1250-14 1250 298 6406 429 9222 195 4192

EHSF-1500-18,8 1500 400 8598 576 12382 261 5610

EHSF-2000-22,4 2000 476 10232 687 14768 311 6685

EHSF-3000-26,4 3000 561 12059 809 17390 366 7868

EHSF-4000-30,6 4000 650 13972 938 20163 425 9136


temperature primary temperature primary 8 temperature primary
75°C - 55°C 5°C - 65°C 60°C - 55°C

temperature secondary temperature secondary temperature secondary


20°C - 60°C 20°C - 60°C 20°C - 55°C

continuous hot continuous hot continuous hot


volume capacity capacity capacity
Type water water water
Three heating coils [l] [kW]
output [l/h]
[kW]
output [l/h]
[kW]
output [l/h]

EHSF-400-7,6 400 162 3482 233 5009 106 2279

EHSF-630-9,1 630 194 4170 279 5997 127 2730

EHSF-800-12,6 800 268 5761 386 8298 175 3762

EHSF-1000-16,5 1000 351 7545 506 10877 229 4923

EHSF-1250-21 1250 447 9609 644 13844 292 6277

EHSF-1500-28,2 1500 599 12876 864 18573 391 8405

EHSF-2000-33,6 2000 714 15348 1030 22141 466 10017

EHSF-3000-39,6 3000 842 18100 1213 26075 549 11801

EHSF-4000-45,9 4000 975 20959 1406 30224 637 13693

temperature primary temperature primary temperature primary


75°C - 55°C 85°C - 65°C 60°C - 55°C

temperature secondary temperature secondary temperature secondary


20°C - 60°C 20°C - 60°C 20°C - 55°C

continuous hot continuous hot continuous hot


volume capacity capacity capacity
Four heating coils Type
[l] [kW]
water
[kW]
water
[kW]
water
output [l/h] output [l/h] output [l/h]

EHSF-400-10,1 400 215 4622 310 6664 140 3009

EHSF-630-12,2 630 260 5589 374 8040 170 3654

EHSF-800-16,8 800 357 7674 515 11071 233 5009

EHSF-1000-22 1000 468 10060 674 14488 305 6556

EHSF-1250-28 1250 595 12790 858 18444 389 8362

EHSF-1500-37,6 1500 799 17175 1152 24764 522 11221

EHSF-2000-44,8 2000 952 20464 1373 29514 621 13349

EHSF-3000-52,8 3000 1122 24119 1618 34781 732 15735

EHSF-4000-61,2 4000 1300 27945 1875 40305 849 18250

EHSF: key to model number

_Type
_ _ _ – _ kW
_ _ _ – _ t_1 _ _ – _t2_ _ _ – _ Vol
_ _ _ – _Opt
_
}
}

}
}

1 2 3 4 5 6 7 8 9 10 11

Type
t2
1st digit: E = ECOTHERM
8th digit: domestic cold water inlet temperature in °C
2nd digit: H = high capacity water heater
9th digit: domestic hot water output temperature in °C
3rd digit: S = spiral internal heating coil
4th digit: F = flat
Vol
10th digit: tank capacity in liters
kW
5th digit: heat exchanger nominal rating in kilowatt
Opt - Options
t1
11th digit: E ... kW = electric heating element ... kW,
6th digit: feed temperature from boiler in °C
G ... kW-t1 = tube heat exchanger ... kW + t1 boiler feed & return °C,
7th digit: return temperature to boiler °C
A = electric anode
Measurements and ports Storage tank ports
D1
D port size angle° description
N2
N1 50-75 kW 1“ ext 180° cold water inlet
N1 100-150 kW 5/4“ ext 180° cold water inlet
N6
N1 200-250 kW 6/4“ ext 180° cold water inlet
N4
N1 300-450 kW 2“ ext 180° cold water inlet
600 Fühlerleiste

N7 N1 500-800 kW DN65 180° cold water inlet


N10 N1 900-1000 kW DN80 180° cold water inlet
N2 50-75 kW 1" int top hot water outlet
H

150

N2 100-150 kW 5/4" int top hot water outlet


1710

1650
600 Fühlerleiste

N3 N2 200-250 kW 6/4“ int top hot water outlet


1250

N8
N11 C N2 300-450 kW 2“ int top hot water outlet
N2 500-800 kW DN65 180° hot water outlet
B

N12
N2 900-1000 kW DN80 180° hot water outlet
280

310

N1

N3 DN 200 180° purification flange (up to 3000 l)
A

N3 DN 400 180° manhole (ab 4000 Liter)


N4 DN 100 180° purification flange (from 630 l)
N6 1/2" IG 225° thermometer
N7 - 225° temperature sensors on top
270° 90°
N8 - 225° temperature sensors on bottom
N10 6/4" IG 180° circulation, electric element
N11 50-100 kW
1“ ext 180° boiler feed boiler return
N12
N11 100-150 kW
45°
180° 5/4" ext 180° boiler feed boiler return
N12
N11 200-250 kW
6/4“ ext 180° boiler feed boiler return
N12
N11 300-450 kW
2“ ext 180° boiler feed boiler return
N12
N11 500-800 kW
DN65 180° boiler feed boiler return
N12
N11 900-1000 kW
DN80 180° boiler feed boiler return
N12

Storage tank dimensions


weight C tipping insulation
storage capacity A B D D1 H
empty* 1/2/3/4 Reg. mass thickness
Model Liter kg mm mm mm mm mm mm mm mm

EHSF-..-..-400 400 80 90 610 100/250/400/550 650 890 1920 1840 120


EHSF-..-..-630 630 105 90 610 100/250/400/550 700 940 1980 1920 120
EHSF-..-..-800 800 120 80 610 100/250/400/550 790 1030 1980 1945 120
EHSF-..-..-1000 1000 147 70 610 100/250/400/550 890 1130 1980 1945 120
EHSF-..-..-1500 1500 228 70 610 100/250/400/550 1100 1340 2025 2010 120
EHSF-..-..-2000 2000 335 70 610 100/250/400/550 1200 1440 2050 2045 120
EHSF-..-..-3000 3000 470 115 660 100/250/400/550 1350 1590 2615 2490 120
EHSF-..-..-4000 4000 557 165 740 100/250/400/550 1500 1740 2630 2750 120
EHSF-..-..-5000 5000 662 165 740 100/250/400/550 1680 1920 2900 2960 120

*) weight of empty storage tank excl. internal heating coil

You might also like