Diesel Generator Set
QSL9 Series
320 kVA, 256 kWe Prime
CPCB IV+ Emission Compliant
Latest Technology and Lowest Operating Cost and
Unmatched Performance Comprehensive Warranty
The Cummins® QSL9 series rugged engine and Highly reliable and durable product
world class Stamford alternator powered diesel Maximum efficiency even at part loads, offering
generator set the advantage of lowest operating costs
Proven technology with Cummins New Electronic 500 Hours/ 1 year service interval
Fuel System Industry acknowledged best-in-class
Exhaust after-treatment and in-cylinder solution to comprehensive warranty on the entire package
meet stringent emission norms including rubber components
Superior finish and aesthetics
Compact in size with optimum power to weight ratio
Single Source Power Assurance
Environment Friendly Power All the major components - the engine, alternator,
Class defining and technologically advanced aftertreatment system, control system and canopy
engine to meet stringent exhaust emission norms are designed, manufactured, and tested by
as per the latest MoEF notification Cummins India
The Cummins® diesel generator sets are available Best and largest customer support network in India,
with the lowest noise levels in its range capable of providing round-the-clock service and
spares support
Diesel Generator Set QSL9 Series Specification Sheet
Engine PS0602 Features
Cummins® QSL9 series, 6 cylinder, In-line 4 stroke, Cummins® PowerStart™
radiator cooled engine PS0602 control is a
Robust and efficient air handling system with microprocessor based generator
• Dry type, Heavy Duty and replaceable paper element set monitoring, metering and
air cleaner with restriction indicator control system with LCD display
• Optimized turbocharger for increased designed to meet the demands
altitude capabilities of today's engine driven generator set
Optimized fuel consumption with common rail electronic AMF Functionality
injection Electronic Governing
Spin on single fuel filter with water separator CAN (J1939) Compatible
Cooling system is designed and tested for 50°C ambient Sync Compatible (Capable to accept external speed
conditions signal from 3rd party sync controller)
Full flow spin on lube oil filter Intuitive operator interface which includes LED backlit
First fill of lube oil and coolant 128X64 pixel graphic display with tactile feel soft-switches
Electrical starter motor with soft start engagement feature & generator set status LED lamps
Battery charging alternator Remote start-stop
2 x 12 V DC battery Audible & Visual warning for Inducement
Suitable for FAE based engine architecture
Engine Metering: Oil pressure, Engine temperature,
Starting battery voltage, Engine running hours
AC Alternator Metering: L-L Voltage and L-N Voltage,
Current (phase and total), kVA (phase and total) and
Frequency. kwh, Total & per phase (kw & kVA), PF, Utility
Voltage and Freq
Engine Protection: Low lube oil pressure, High/Low
coolant temperature, Battery High/Low/Weak Volts, Fail to
Crank/Start, Sensor failure, Cranking lockout, Low fuel level
AC Alternator Protection: Over/Under Voltage, Over/Under
Frequency, Loss of AC sensing. Overspeed, Over Current,
kW Overload
Data Logging: Engine hours, Control hours and upto
5 recent fault codes
Alternator Configurable glow plug control
12/24 Volt DC operation
STAMFORD HCI444D alternator frames from Cummins
Sleep mode
Generator Technologies
Modbus interface (RS485 RTU)
Brushless type, Screen protected, Revolving field,
In Power compatible (PC based service tool)
Self-excited alternator conforming to IS/IEC 60034-1
Certifications - meets the requirement of relevant ISO, EN,
Better motor starting capability
Mil Std. and CE standards
Best in class efficiency
Maintenance due alarm based on Engine Run Time and
Compact design with sealed bearings for longer life
due date
and lesser maintenance
Fuel and DEF level visual display
Impregnation on all wound components for
Exerciser scheduler
better mechanical strength
Silencer
EATS
Hospital Grade Silencer inside canopy with rain cap
Single module architecture supplied by
suitably optimized to meet stringent noise limit
Cummins Emission Solutions
Silencer specifically tuned to EATS
Compact design enabling optimized genset size
Integrated control module for engine and EATS
Best in class Proven technology for meeting
stringent emission norms
Mounting Arrangement
Engine and alternator are mounted on a common MS
fabricated base frame with AVM pads
Control Panel
Skid mounted radiator
Control panel is powder coated for weather-proof and long- Base frame with integral fuel tank and DEF tank is provided
lasting finish. The control panel consists of the following parts: with drain plug, air vent, inlet and outlet connection and
provision for cleaning
PS0602 Controller
Bus bars with suitable capacity with incoming/ Optional
outgoing terminals
Indicating lamps for 'Load ON' and 'Set Running' Alternator : PMG and Space Heater
Instrument fuses duly wired and ferruled Controller : PCC3.3
MCCB of suitable rating with short circuit protections
AC/DC separation inside control panel for safety
Diesel Generator Set QSL9 Series Specification Sheet
Acoustic Enclosure Remote monitoring system
Specially designed to meet stringent MoEF/ CPCB norms Compact & robust device
of 75 dBA@1mtr at 75% load under free field conditions Real time DG status & monitoring
The acoustic enclosure is made CRCA sheets in 4G compatible
Munsell green shade and a structural/sheet metal Compatible for 12/24 V DC
base frame painted in black Reports & Notification – Alerts & Warning
11 tank pretreatment process and UV resistant powder Isolated RS 485 interface
coating of all parts to withstand extreme environment Device location using triangulation
High quality noise absorbent and fire-retardant grade
acoustic Insulation material (Rockwool) complying to IS 8183
Top lifting for easy handling at customer site
External fuel & DEF filling provision
Technical Data
Generator Set Specification
Technical Model
Data CI 320D5P
Duty Prime
Power Rating kVA / kWe 320/256
No. of Phases 3
Output Voltage and Frequency (V and Hz) 415 V, 50 Hz
Power Factor 0.8 (lagging)
Current (A) 445
RPM 1500
Engine Specification
Make Cummins®
Model QSL9-G20
Required Certified Power for Rated kVA (hp) 395
Cooling Liquid Cooled (EG Compleat 50:50)
DEF AUS 32 (Premix) as per ISO 22241
Aspiration Turbocharged, Charge Air Cooled
No. of cylinders 6, In-line
Bore (mm) x Stroke (mm) 114 x 145
Compression ratio 16.7:1
Displacement (litre) 8.9
Fuel High Speed Diesel
Performance class of generator set ISO 8528-5 G2
Starting system 24 V DC Electrical
Lube oil specification CK4
Lube oil sump capacity, High-Low level (litre) 30-19.97
Total lubrication system capacity 21.5
(Litre) 31.7
20.3
Total coolant capacity (litre) 36
Exhaust pipe size (inch) 6
Total wet weight (Engine+Radiator)* (kg) 918.2
Length X Width X Height (Coolpac) (mm) 1128 x 791 x 1277
Mean Piston speed (m/s) 7.2
Combustion air intake @100% load (±5%) (cfm) 689
Exhaust Temperature (0C) 539
Diesel Generator Set QSL9 Series Specification Sheet
Alternator Specification
Make STAMFORD(CGT)
Alternator Frame HCI444D
Enclosure IP 23
Voltage regulation (Max.) ±1%
Class of Insulation H Class
Winding Pitch 2/3
Stator Winding Double layer lap
Rotor Dynamically Balanced
Waveform distortion/ No load < 1.5 %, Non distorting balanced linear load < 5 %
Total Harmonic Distortion
Maximum Unbalanced less than or equal to 25%
Load across phases•
Telephonic Harmonic factor < 2%
Rating Definitions Conformance Standards
• IS/IEC 60034-1
Prime Power (PRP):
• ISO 1460
Applicable for supplying power to
• ISO 8528
varying electrical load for unlimited hours.
• ISO 3046
Prime Power (PRP) is in accordance with
• ISO 9001
ISO 8528.
• ISO 13018
Typical Enclosed Genset Dimensions
DEF Tank Standard Fuel tank
Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Wet Weight" (kg)
Capacity (litre) Capacity (litre)
CI 320D5P 320 5000 1500 2465 4530 60 515
" Approximate Weight
Cummins Power Systems Offices
Bengaluru: Tel.: (080) 2325 9161 / 63, 2325 9165 / 67 | Fax: (080) 2325 9164
Authorised Representative Chandigarh: Tel.: (0172) 224 0371-73 | Fax: (0172) 224 0372
Chennai: Tel.: (044) 2446 8110 / 2446 8113 | Fax: (044) 2491 1120
Gurgaon: Tel.: (0124) 391 0900-01 | Fax: (0124) 391 0916
Hyderabad: Tel.: (040) 2340 9970 / 2340 9980 | Fax: (040) 2340 9990
Jaipur: Tel.: (0141) 236 4944 | Fax: (0141) 403 8794
Kolkata: Tel.: (033) 2287 8065 / 2287 2481 | Fax: (033) 2290 3839
Lucknow: Tel.: (0522) 230 5049 / 230 5059 | Fax: (0522) 230 5035
Mohali: Tel.: (0172) 224 0371 I 72 / 73 | Fax: (0172) 224 0371 / 72 / 73
Vadodara: Tel.: (0265) 233 0627 / 3053627 | Fax: (0265) 234 0623
Visit our Facebook page at :
Cummins Power Generation India
Cummins India Limited
"Our energy working for you." Power Systems Business
Cummins India Office Campus
Tower-A, 8th Floor, S. No. 21
Balewadi, Pune - 411 045 (India)
Cummins is registered trademarks of Cummins Inc.
Specifications are subject to change without notice. Email : cpgindia@[Link]
PSBU/CPCB IV+/QSL9/Rev-00/07 2023 [Link]