2022 | INDUSTRIAL VENTILATION

Turbo
Inline mixed-flow fans

Use Air flow:


Supply and extract ventilation systems up to 1750 m³/h
installed in various premises. 486 l/s
Mounting in kitchens, bathrooms and Power:
other humid premises. from 23 W
Ventilation air ducts requiring high
pressure, powerful air flow and low noise Noise level:
level. from 27 dBA
Compatible with ∅ 100 up to 315 mm round
air ducts.

Design Mounting
The casing is made of low-flammable polypropylene. Due to the compact design the fan is the ideal solution for mounting in
Ventilation unit with terminal box. Can be turned to any position. limited spaces, including space behind a false ceiling.
Special design of the casing permits easy dismantling of the impeller and The fan can be installed in any section of the ventilation system from
motor block for fan servicing without dismantling the air duct. intake to the end of the ductworks.
Wall or ceiling mounting with a mounting plate.
TD: mounting kit for installation of one diameter fans in parallel
Motor (for boosting capacity)
Two-speed single-phase motor on ball bearings.
Equipped with thermal overheating protection.
INLINE FANS

Speed control
The control (minimum speed, maximum speed and shutdown) is executed
with the integrated three-position switch (US modification) or with the
external switch for multi-speed fans (specially ordered accessory).
Smooth speed control is possible with a built-in speed controller
(FR1 modification) or an external thyristor speed controller (available
upon separate order). TL: mounting kit for installation of one diameter fans in series (for boosting
pressure).

Accessories
Backdraft Temperature Speed
Silencers Filter boxes Electric heaters Water heaters Air dampers Clamps Timers/Sensors
air dampers controllers controllers

SD KFBK / KFBT EKH WKH VRV VK / VKA K MLCD E2 CDT / CDP TE(TI) / HSE(HSI) /
LSE(LSI) / IRSE(IRSI)

8 blaubergventilatoren.de
blaubergventilatoren.de

Modifications
T: turn-off delay timer adjustable from 2 to 30 minutes. G1: speed controller, temperature controller with external temperature
US: three-position speed switch. sensor (cable length 4 m), power cable with mains plug.

FR1: smooth speed controller adjustable from 0 to 100 % and power cable
with mains plug.

GT1: speed controller, temperature controller with external temperature


sensor (cable length 4 m), 5 min timer switch and power cable with mains
plug.
GI1: speed controller, temperature controller with integrated temperature
sensor and power cable with mains plug.
GTI1: speed controller, temperature controller with integrated temperature
sensor, 5 min timer switch and power cable with mains plug.
The G1 and GI1 modifications enable automatic speed control depending
on indoor temperature. The optimal ventilation solution for premises
requiring permanent temperature control as greenhouses, orangeries, etc.
W1: power cable with mains plug.

Designation key
Series Duct diameter [mm] Modifications
Turbo 100; 125; 150; 160; 200; T: turn-off delay timer adjustable from 2 to 30 minutes
250; 315 US: three-position speed switch

INLINE FANS
FR1: smooth speed controller adjustable from 0 to 100 % and power cable with mains plug
G1: speed controller, temperature controller with external temperature sensor, power cable with mains plug
GT1: speed controller, temperature controller with external temperature sensor, 5 min timer switch and power cable with mains plug
GI1: speed controller, temperature controller with integrated temperature sensor and power cable mains plug
GTI1: speed controller, temperature controller with integrated temperature sensor, 5 min timer switch and power cable with mains plug
W1: power cable with mains plug

Overall dimensions [mm]


Model ∅D ∅ D1 B H L Weight [kg]

Turbo 100 97 164 196 241 303 1.68


Turbo 125 123 164 196 241 258 1.79
Turbo 150 148 187 220 251 289 3.18
Turbo 160 158 187 220 251 289 3.23
Turbo 200 199 209 239 261 295.5 3.8
Turbo 250 247 257 287 323 383 7.83
H

Turbo 315 310 323 362 408 445 11.7

INDUSTRIAL VENTILATION | 2022 9


2022 | INDUSTRIAL VENTILATION

Technical data
Parameters Turbo 100 Turbo 125 Turbo 150 / Turbo 160

Speed min max min max min max


Voltage [V] 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230
Frequency [Hz] 50/60 50/60 50/60 50/60 50/60 50/60
Power [W] 23 25 25 29 42 50
Current [A] 0.10 0.11 0.11 0.13 0.19 0.22
Maximum air flow [m³/h (l/s)] 170 (47) 220 (61) 230 (64) 345 (96) 430 (119) 560 (156)
RPM [min⁻¹] 1980 2545 1535 2265 1940 2620
Sound pressure level at 3 m [dBA] 27 32 29 34 32 44
Max. transported air temperature [°C] +60 +60 +60
SEC class C B B
IP rating IPX4 IPX4 IPX4
Motor IP rating IPX4 IPX4 IPX4
ErP – – 2018
To comply with ErP 2018 it is necessary to use a speed controller and local demand control typology (connect the sensor).

TURBO 100
160

Static pressure [Pa]


Sound power level, Octave frequency bands [Hz]
Total LpA 3 m LpA 1 m
A-weighted 63 125 250 500 1000 2000 4000 8000 140

Min speed 120


LwA to inlet [dBA] 54 19 35 50 49 44 37 25 17 33 43
100
max.
LwA to outlet [dBA] 53 17 34 50 49 48 36 24 17 32 42
80
LwA to environment [dBA] 47 14 29 43 43 39 33 22 15 27 37
min.
Max speed 60

LwA to inlet [dBA] 59 24 34 53 54 53 48 37 26 38 48 40


LwA to outlet [dBA] 57 23 33 52 52 52 47 37 26 37 47
20
INLINE FANS

LwA to environment [dBA] 52 18 29 46 48 47 43 33 23 32 42


0
0 40 80 120 160 200
Air flow [m³/h]

TURBO 125
Static pressure [Pa]

Sound power level, Octave frequency bands [Hz] 140


Total LpA 3 m LpA 1 m
A-weighted 63 125 250 500 1000 2000 4000 8000
120
Min speed
LwA to inlet [dBA] 54 26 38 52 50 44 38 27 17 34 44 100

LwA to outlet [dBA] max.


54 25 37 51 49 43 38 28 18 33 43 80
LwA to environment [dBA] 49 21 32 46 45 40 35 25 16 29 39
60 min.
Max speed
LwA to inlet [dBA] 60 20 31 57 51 51 50 39 27 39 49 40

LwA to outlet [dBA] 59 20 31 56 51 51 49 39 26 38 48


20
LwA to environment [dBA] 54 16 27 51 46 47 45 36 24 34 44
0
0 50 100 150 200 250 300 350
Air flow [m³/h]

TURBO 150 / 160


Static pressure [Pa]

Sound power level, Octave frequency bands [Hz]


Total LpA 3 m LpA 1 m 250
A-weighted 63 125 250 500 1000 2000 4000 8000

Min speed
200
LwA to inlet [dBA] 59 31 45 54 52 54 48 35 29 38 48
LwA to outlet [dBA] 63 37 49 56 56 60 48 39 30 42 52 max.
150
LwA to environment [dBA] 52 21 30 48 48 45 42 34 23 32 42
min.
Max speed 100

LwA to inlet [dBA] 69 38 51 57 62 60 66 49 44 48 58


LwA to outlet [dBA] 72 42 55 66 67 68 65 53 45 52 62 50

LwA to environment [dBA] 65 23 37 56 59 57 61 47 35 44 54


0
0 100 200 300 400 500 600
Air flow [m³/h]

10 blaubergventilatoren.de
blaubergventilatoren.de

Parameters Turbo 200 Turbo 250 Turbo 315

Speed min max min max min max


Voltage [V] 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230 1 ~ 230
Frequency [Hz] 50/60 50/60 50/60 50/60 50/60 50/60
Power [W] 76 108 125 177 227 315
Current [A] 0.34 0.48 0.54 0.79 0.99 1.42
Maximum air flow [m³/h (l/s)] 805 (224) 1080 (300) 1070 (297) 1360 (378) 1420 (394) 1750 (486)
RPM [min⁻¹] 1915 2380 1955 2440 2115 2505
Sound pressure level at 3 m [dBA] 39 45 44 51 41 52
Max. transported air temperature [°C] +60 +60 +60
SEC class B – –
IP rating IPX4 IPX4 IPX4
Motor IP rating IPX4 IPX4 IPX4
ErP 2018 2018 2018
To comply with ErP 2018 it is necessary to use a speed controller and local demand control typology (connect the sensor).

TURBO 200
350

Static pressure [Pa]


Sound power level, Octave frequency bands [Hz]
Total LpA 3 m LpA 1 m
A-weighted 63 125 250 500 1000 2000 4000 8000 300

Min speed
250
LwA to inlet [dBA] 66 38 50 58 59 60 59 55 45 45 55
LwA to outlet [dBA] 200 max.
64 40 50 54 58 59 57 51 44 43 53
LwA to environment [dBA] 60 27 42 49 54 55 54 46 34 39 49
150 min.
Max speed
LwA to inlet [dBA] 71 41 50 63 64 65 64 62 52 50 60 100

LwA to outlet [dBA] 70 43 52 61 66 64 63 58 51 50 60 50

INLINE FANS
LwA to environment [dBA] 65 34 43 54 60 60 60 53 41 45 55
0
0 200 400 600 800 1000
Air flow [m³/h]

TURBO 250
500
Static pressure [Pa]

Sound power level, Octave frequency bands [Hz]


Total LpA 3 m LpA 1 m
A-weighted 63 125 250 500 1000 2000 4000 8000
400
Min speed
LwA to inlet [dBA] 72 48 57 63 66 69 64 54 45 52 62
300 max.
LwA to outlet [dBA] 75 48 56 64 70 71 66 56 45 54 64
LwA to environment [dBA] 65 32 51 57 61 59 56 45 32 44 54
200 min.
Max speed
LwA to inlet [dBA] 78 52 62 66 71 75 72 62 52 58 68
100
LwA to outlet [dBA] 81 52 60 66 76 77 74 63 52 60 70
LwA to environment [dBA] 72 35 50 63 69 66 63 53 40 51 61
0
0 200 400 600 800 1000 1200 1400
Air flow [m³/h]

TURBO 315
Static pressure [Pa]

Sound power level, Octave frequency bands [Hz]


Total LpA 3 m LpA 1 m 600
A-weighted 63 125 250 500 1000 2000 4000 8000

Min speed 500

LwA to inlet [dBA] 72 43 54 62 67 66 67 58 47 52 62


400
LwA to outlet [dBA] max.
70 45 57 59 64 66 63 56 46 50 60
LwA to environment [dBA] 62 28 51 53 57 57 54 46 36 41 51 300
min.
Max speed
200
LwA to inlet [dBA] 80 50 59 68 73 77 74 70 59 60 70
LwA to outlet [dBA] 78 51 60 66 70 75 71 66 57 58 68 100
LwA to environment [dBA] 72 37 51 66 66 67 65 58 48 52 62
0
0 400 800 1200 1600
Air flow [m³/h]