Bel Power Solutions MAP55 Series of power supplies provides
reliable, tightly regulated DC power for industrial systems. MAP55
series complies with EMC product standard EN 61204-3. All RoHS
compliant units bear the CE Mark.
The MAP55 utilizes a thermally efficient U-channel chassis design.
Other mechanical design innovations include metric and SAE
mounting inserts on each mounting surface to provide integration
flexibility. Dual-mode connectors provide traditional terminal block
connections or popular single row Molex connector mating.
Single-output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
• Wide Range Input for 110/220 VAC Applications
• Compact Footprint: 6.0 x 3.27 x 1.6 inch (152.4 x 83.1 x 40.6 mm)
• Greater than 225000 Hours MTBF
• Metric and SAE Mounting Inserts
• RoHS Compliant
• CE Marked to Low Voltage Directive
• Meets EMC standards: EN 61204-3
EN 55032
EN 61000-3-2
EN 61000-3-3
2 MAP55 Series
MAX PEAK RIPPLE
OUTPUT ADJUSTMENT LINE LOAD INITIAL SETTING
MODEL8 OUTPUT OUTPUT &
VOLTAGE RANGE REGULATION REGULATION ACCURACY
CURRENT CURRENT1 NOISE2
MAP40-1005G 5V 4.7V to 5.5V 8A 11A 0.2% ±1.5% 1% 5.0V to 5.2V
MAP55-1012G6 12V/15V 11.4V to 15.75V 5.0/4.0A3 5.8/4.7A3 0.2% ±1% 1% 12.0V to 12.2V
MAP55-1024G6 24V/28V 23.5V to 28.5V 2.5/2.2A3 2.9/2.5A3 0.2% 1% 1% 23.8V to 24.2V
PEAK RIPPLE
OUTPUT ADJUSTMENT OUTPUT LINE LOAD INITIAL SETTING
MODEL8 OUTPUT &
VOLTAGE RANGE CURRENT REGULATION REGULATION ACCURACY
CURRENT4 NOISE2
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
+12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V
MAP55-4000G7
-5V Fixed 0.5A 1A5 0.5% 2% 1% -4.8V to -5.2V
5
-12V Fixed 0.5A 1A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
+24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V
MAP55-4001G7
-12V Fixed 0.5A 1A5 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 0.5A 1A5 0.5% 2% 1% 11.6V to 12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
+12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V
MAP55-4002G7
-12V Fixed 0.5A 1A5 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 0.5A 1A5 0.5% 2% 1% 11.6V to 12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
+15V Fixed 2.5A 3.5A 0.2% 2% 1% 14.6V to 15.4V
MAP55-4003G7
-5V Fixed 0.5A 1A5 0.5% 2% 1% -4.8V to -5.2V
-15V Fixed 0.5A 1A5 0.5% 2% 1% -14.4V to -15.6V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
+24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V
MAP55-4004G7
-15V Fixed 0.5A 1A5 0.5% 2% 1% -14.5V to -15.5V
+15V Fixed 0.5A 1A5 0.5% 2% 1% 14.5V to 15.5V
1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 MAP55-1012G output currents are expressed as 12V/15V operation. MAP55-1024G output currents are expressed as 24V/28V operation.
4 Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
5 Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
6 Maximum 60 W with 150LFM (Linear Feet per Minute) air cooling or maximum 50 W with convection cooling.
7 Maximum 55 W with 200LFM (Linear Feet per Minute) air cooling or maximum total output power 45 W at 40°C ambient operating temperature
for models with no cover and 40 W for models with cover / convection cooling.
8 Models without suffix G are not RoHS-compliant (Leaded solder used) and are not recommended for new designs or already EOL.
[Link]@[Link]
MAP55 Series 3
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
90 132
Input Voltage - AC Continuous input range VAC
175 264
Input Frequency AC input 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads 90 VAC
Hold-up Time Nominal AC Input Voltage (115 VAC), full rated load 20 ms
Input Current 90 VAC (55 W load) 1.6 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25°C 38 APK
Operating Frequency Switching frequency of power supply (varies with load) 22 180 kHz
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load @ 115 VAC. Varies with distribution of loads among outputs. 73% typical
MAP55-1012G 0.21
Minimum Loads MAP55-1024G 0.11 Amps
MAP40-1005G and all multiple output models, main channel only 0.50
Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart
Continuous output power, all multiple output models. 55
Output Power Peak output power (60 s maximum, 10% duty cycle), all multiple output 65 Watts
models.
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 %
Varies by output. Total regulation includes: line changes from 90-132 VAC
Regulation or 175-264 VAC, changes in load starting at 20% load and changing to See Model Selection Chart
100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load
Transient Response 500 μs
change, 4% max. deviation. (Main output of multiple output units.)
Turn-on Delay Time required for initial output voltage stabilization. 1 4 Sec
Time required for output voltage to rise from 10% to 90%. (Nominal rise
Turn-on Rise Time 7 ms
time for MAP55-1024G is 36 msec.)
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
MAP40-1005G 5.5 6.8
MAP55-1012G 17.5 19.7
Overvoltage Protection V
MAP55-1024G 32.0 36.0
Main output only of multiple output units. 5.6 6.8
Fully protected against output overload and short circuit.
Overload Protection
Automatic recovery upon removal of overload condition.
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
Approved to the latest edition of the following standards:
Agency Approvals
UL/CSA 62368-1, IEC 62368-1, and EN 62368-1
Input to Chassis 2121
Dielectric Withstand Voltage VDC
Input to Output (tested by manufacturer only) 4242
Insulation Resistance Input to output 7 MΩ
Touch Current EN 62368-1, 264 VAC 600 μA
Asia-Pacific Europe, Middle East North America
+86 755 298 85888 +353 61 49 8941 +1 866 513 2839
© 2022 Bel Power Solutions & Protection BCD.00564_F
4 MAP55 Series
Conducted emissions EN 55032 Class B
Radiated emissions EN 55032 Class A
BASIC PERFORMANCE
PHENOMENON TEST ITEM TEST SPECIFICATION
STANDARD CRITERIA
80 - 1000 MHz
10 V/m
80%
Frequency 1,4 to 2 GHz
Radio-frequency electromagnetic field
EN 61000-4-3 Field strength 3 V/m A
Amplitude modulated
AM 1 kHz 80%
2 to 2,7 GHz
1 V/m
80 %
Frequency 0,15 to 80 MHz
Conducted disturbances
EN 61000-4-6 Amplitude 10 V A
induced by radio-frequency fields
AM 1 kHz 80 %
0 % during 1/2 cycle
0 % during 1 cycle
40 % during 10/12 cycles
A
at 50/60 Hz
Voltage dips EN 61000-4-11 Residual voltage
70 % during 25/30 cycles
at 50/60 Hz
80 % during 250/300 cycles
B
at 50/60 Hz
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
Operating 10k
Altitude Feet
Non-operating 40k
Derate linearly above 50°C by 2.5% per °C to a At 100% load: 0 50
Operating Temperature °C
maximum temperature of 70°C (with 200 LFM) At 50% load: 0 70
Storage Temperature -40 85 °C
Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.02 ±0.03 %/°C
Relative Humidity Non-condensing 5 95 %RH
Shock Operating, peak acceleration 20 G
Vibration Random vibration, 10 Hz to 2 kHz, 3 axis 6 GRMS
PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS
152.4 x 83.1 x 40.6 mm
Dimensions
6.00 x 3.27x 1.6 in
0.55 kg
Weight
1.1 lb
Order the cover number 412-59584-G separately.
For convection cooled applications, derate output power to 40 watts
on multiple output units,
Cover (Option) 50 watts on MAP55-1012G and MAP55-1024G and
40 watts on MAP40-1005G.
152.4 x 83.1 x 45.0 mm
Dimensions:
6.00 x 3.27 x 1.77 in
[Link]@[Link]
MAP55 Series 5
CONNECTOR CONDITIONS / DESCRIPTION
6-32 screw wire clamps on 0.312" (7.9 mm) centers
Input & Output Connectors
0.045" (1.1 mm) square pins on 0.156" (3.4 mm) centers
Matting Connectors Molex Series 2139, 6442, or 41695
Chassis 0.090" (2.3 mm) aluminum alloy, with clear finish
Figure 1. Mechanical Drawing
For more information on these products consult: [Link]@[Link]
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
Asia-Pacific Europe, Middle East North America
+86 755 298 85888 +353 61 49 8941 +1 866 513 2839
© 2022 Bel Power Solutions & Protection BCD.00564_F