Technical Data

Sheet

CIKOgrout GP
Non-shrink, high strength cementitious grout

Description
CIKOgrout GP is a ready to use general purpose
non-shrink, cementitious grout for interior and
exterior use for filling gaps between similar or
dissimilar substrates. CIKOgrout GP is suitable
for anchoring pre-cast columns, anchor bolts
and fence posts, etc.

CIKOgrout GP is a balanced blend of select


cement type, graded Silica aggregate , flow
enhancing and shrinkage compensating
additives resulting in a free-flow, high strength
grout. Physical properties
Form Powder
Properties Cement grey
Colour
(standard)
 Single component system and only
addition of water required at site. W/P 0.14 to 0.16
 Controlled expansion in plastic and in ≈2140±50 kg/m
3
Density
early and late hardened stage. (Fresh)
 High early and final strength. Flow Proprietary
 Low permeability. 150%
ASTM C 1437
 Chloride free and will not rust or harm W/P=0.16
metal on contact. Linear coefficient of
 Frost and salt resistant. thermal expansion <0.1%
ASTM C531
Application area Early height change of
0 to 4 %
CIKOgrout GP can be used for the grouting of, grout ASTM C940
 Machinery base plate. Height change of
0 to 0.3%
 Anchoring. hardened cylinder grout
(at 1,3,7,28 days)
 Turbine base. ASTM C1090
 Bridge bearing. 1 day ≥25 N/mm
2
Compressive strength
 Potable water equipment.
2
3 days ≥35 N/mm
ASTM C109 @ 2
 Concrete structures. W/P=0.14
7 days ≥50 N/mm
2
 Storage rack base. 28 days ≥60 N/mm
 Pre-cast concrete parts. Flexural strength 3 day ≥4 N/mm
2

 Rails grouting. ASTM C348 @ 7 days ≥7 N/mm


2

 Industrial plants. W/P=0.14 28 days ≥9 N/mm


2

Applicable standards Application Thickness* 10 to 100mm


 CIKOgrout GP complies with the Corps *Note: higher thickness may be achieved by adding 10mm aggregate with a ratio
ASTM C1107 grade B & C. up to 40% by weight to the bag. Consult CIKO technical service department for
further support.
 Complies with Qatar Construction
Coverage / Yield
Specifications QCS.
25 kg bag of CIKOgrout GP mixed with 3.50 litres of
water, yields 13.0 litres of grout.

1
Application instructions Precautions

0 0
Surface preparation Ambient temperature shall be between 5 -35 C.
Clean the concrete surface to remove loose and  The temperature of both the grout and elements
unsound material by means of water blasting or coming into contact with the grout should be in
any suitable means to attain a sound concrete the range of 10°C to 35°C.
surface. The acceptable surface should be free  Do not overwork and avoid using mechanical
from traces of oil, grease, curing compounds or vibration.
any other contaminations.  Under no circumstances should CIKOgrout GP
Formwork be re-tempered by the later addition of water.
Watertight formwork should be made around
grouting area to the required height. It is Packaging
recommended to restrict width of the shoulders CIKOgrout GP is available in 25kg moisture resistant
around base plate to maximum 50mm from the bags.
face of the base plate to avoid generation of
expansion cracks under un-restrained Shelf life
conditions. CIKOgrout GP made to mortar CIKOgrout GP has a shelf life of 12 months if stored in
consistency can be used to seal gaps between accordance with CIKO instructions.
formwork and concrete face to made formwork
watertight. Storage
CIKOgrout GP should be stored under enclosed shaded
Soaking
area.
Prior to grouting, fill water inside the formwork
and soak the concrete surface for approximately
6 hours. Just before grouting, remove water Health & safety
completely from the formwork, anchor bolt Use standard dust mask to avoid inhalation of dust.
pockets etc. by mechanical means or using Powder when wet or moist can cause burns to skin and
sponge so that the surface should be free from eyes which should be protected during use. If comes in
standing water. contact with skin/eyes, flush with plenty of fresh water
and seek medical advice.
Mixing
CIKOgrout GP is a ready to use material Refer Material Safety Data Sheet for further details.
requiring only addition of 3.5 to 4.0 litres of water
for mixing. Measure required amount water for Technical Support
each batch mix and dispense into concrete
mixer. Slowly add CIKOgrout GP powder into For any technical support, do not hesitate to contact
concrete mixer keeping the mixer in running CIKO team at any time as CIKO offers on and off site
mode. Mix the grout for 5 minutes to get a services to end users, specifier and contractors.
homogenous and lump free grout.
Note: It is essential that a mechanically powered More from CIKO Middle East
grout mixer in addition to chilled water to obtain
A wide range of construction chemical products are
the optimum properties and results.
manufactured by CIKO Middle East which includes:
Placing  Concrete admixtures and additives
Pour the mixed grout from one side or corner of  Waterproofing and damp proof coatings
the base plate to avoid air voids. Maintain a
 Surface treatments
minimum of 15cm pouring head to achieve
maximum flow property of grout. In case of  Flooring and toppings
machinery installation, anchor bolt pockets shall  Grouts and anchors
be grouted prior to base plate grouting.  Tile adhesives and grout
 Adhesives and bonding agent
Curing
 Concrete repair materials
The exposed area of grout shall be cured as per
standard curing practices.  Protective coating
CIKO range of curing compounds shall be used in in  Joint Sealants
cases of vertical surfaces or exposed and harsh  Moulding compounds
conditions.

TDS/GA20 Rev:4 Issue:C