LOGOS One
Fully automated innovative tissue processor
Designed for reliability and unmatched tissue quality
Focuses on the user and on specimen safety
Allows batch and continuous flow operations

MILESTONE
H E L P I N G
P A T I E N T S
LOGOS One. Unmatched workflow options

Day operations
As a fully automated, single retort, rapid tissue processor

Night operations
As a fully automated, single retort, overnight tissue processor

NIGHT

Processing Wax
retort retort Wax
transfer

During the day, LOGOS One can run urgent biopsies in a short time as a fully automated unit.
Molten wax is automatically transferred to and from the processing retort for the impregnation step.
During the night, LOGOS One can run protocols as an advanced and resistant heated processor. Improved
operations are carried out through xylene-free protocols with only four reagents: formalin, ethanol, isopropanol
and wax. It also has an optional delayed start mode, with a desired completion time set by the user, to allow
additional fixation time, if needed.

LOGOS One. An additional unique feature...

Day operation enhanced


As a sequential, dual retort, continuous flow tissue processor

Processing Wax
retort retort Manual Processing Wax
transfer retort retort

1 - In the processing retort the 2 - At the end of the processing 3 - A new rack is then manually
first rack undergoes a fixation, a cycle, the rack is manually placed in the processing retort.
dehydration and a clearing phase. transferred to the wax retort. The two racks are processed
simultaneously.
LOGOS One.
The state-of-the-art processor for superior tissue quality

Only two processing steps (1 ethanol and 1 isopropanol)


Fully automated processing in overnight and in rapid mode
Parallel processing in continuous flexible-size batch mode
Up to 140 cassettes with 1 gallon standard reagent containers
Up to 210/300 cassettes with 5 liter reagent containers
Any type of tissue can be processed, up to 10 mm of thickness
Xylene or xylene-free protocols
LOGOS One
Unmatched tissue quality

All types of specimens can be easily


processed with the LOGOS One.
Excellent quality results for H&E, Breast Colon
Immunohistochemistry, FISH and
molecular studies.

Cartilage Stomach

Rapid optimized tissue-processing

1 Reduced number of processing steps


The Logos One carries out rapid protocols
only with 1 step of ethanol and 1 step of
isopropanol, thanks to its advanced retort
heating system 2
1
2 Fast ramp time and precise temperature control
The resistive heating elements, built in the
aluminium retort walls, ensure a fast and
homogeneous temperature increase of the
reagents to the pre-set processing values.

3 Rapid and optimal reagent diffusion


The diffusion of the reagent is guaranteed by a
highly efficient magnetic stirrer bar at the bottom 3
of the retort, ensuring an optimal flow through
all of the cassettes of each rack level. LOGOS One. Reagent processing retort
LOGOS One. Unmatched processing times
Enables same-day diagnosis with a flexible and adaptable fast
processing schedule.

Specimen Improved workflow with sequential


Rapid and fully automated protocols
thickness processing in continuous batch mode

1 mm Full batch* processed in 2 h 10 minutes


(i.e. GI/Endoscopic Batch* loading every 1 h 47 minutes
(excluding fixation)
biopsies)

Full batch* processed in 3 h 34 minutes


3 mm (excluding fixation)
Batch* loading every 2 h 31 minutes

Full batch* processed in 5 h 54 minutes


5 mm (excluding fixation)
Batch* loading every 3 h 34 minutes

Note: above times are referred to ethanol/isopropanol 2 layer protocols, excluding reagent movement.
* Up to 140 cassettes with 1 gallon containers and up to 210 cassettes with 5 liter reagent jars

LOGOS One. Dramatic workflow improvement


Throughout the day the instrument can process urgent and small biopsies on demand.
These samples/biopsies, which can constitute 40-60% of the workload of a histopathology lab, are
rapidly processed. The short processing time allows embedding, cutting and staining of specimens
so that the slides are available for the pathologist on the same day. The remaining cassettes can be
automatically processed during the night.

Conventional Processing LOGOS One Processing


Workload

Workload

7 am Time 4 pm 7 am Time 4 pm
LOGOS One software. Intuitive, icon-driven, smartphone-like
Touch Control

Enter the appropriate user access level.


The operator can recall and run
existing processing protocols. Only the
administrator can modify programs or store
new ones.

Intuitive touch display.


Icon-driven and user friendly.

The administrator can easily set up a new


protocol by selecting the desired settings
from the touchscreen interface.

The complete summary of the new An event log lists all the activities
protocol is displayed for approval or carried out with the unit, providing
modification before starting the process. documentation for service and quality
assurance purposes.
LOGOS One. Focus on operator and specimen safety
Save time
Direct transfer of solutions from commercial containers
(5l / 1 US gal supplier bottles) into the processing retort.
No need of filling tanks as required by conventional tissue
processors.

High safety standards


No pouring, no fumes.

Ultra protection for users safety


Fully enclosed system with a twin extraction system of fumes
at the retort opening. The slide-out reagent drawer is provided
with an efficient ventilation/exhaust system.

Error-free reagents replacement


The Logos One reagent replacement is error-free thanks to
a barcoding check system. When the container needs to be
replaced, the operator can double-check the correctness of the
reagent used and its positioning in the drawer.
1. Scan the barcode on the bottle to check the proper reagent.
2. Scan the barcode of the wall’s back label to check the correct
position of the bottle.

1
Packed with the latest technology
for an improved work environment 2
3
1 “Soft-close” cover for enhanced safety

2 Heated PTFE coated internal surface to avoid the


condensation of reagents for consistent processing 4
and enhanced operator safety

3 Swing-up control panel cover for easy access to


condensation traps

4 Easy and safe transfer of exhausted wax through a


heated PTFE connector
Conventional processing with “unconventional” options
An innovative unit surveillance system
MileWATCH
The optional middleware MileWATCH monitors from remote, in real time, 24/7 the processor status
with live notifications. MileWATCH can be set to send e-mails to the interested parties: protocol status
to the laboratory manager, alerts to service personnel, providing all the necessary information for a
prompt action to assure trouble-free operations.

E-mail notification

LOGOS One MileWATCH Server Laboratory Informtion System

Fully automated processing and embedding in one unit


Synergy
Synergy is a revolutionary Patented (n. EP 2 439 510 A1) method to automatically embed tissues as
part of the processing protocols. Thanks to a dedicated rack and consumables, the same processor unit
can also carry out automatic embedding. The Synergy is available as an option for the LOGOS One unit.

SYNERGY performance
N° of blocks per run: 45. Processing cycles:
• 1mm thickness processed and embedded in 2h 10m*
• 3mm thickness processed and embedded in 3h 34m*
• 5mm thickness processed and embedded in 5h 54m*

SYNERGY benefits
• Optimal flat positioning of small biopsies such as needle core biopsy
• Flexibility to run standard processing automatic embedding

* Time for reagents loading/unloading excluded

MILESTONE MILESTONE Srl - Via Fatebenefratelli, 1/5 - 24010 Sorisole (BG) - Italy In your country:
Tel: +39 035 4128264 - Fax: +39 035 575498
www.milestonemedsrl.com - email: [email protected]
UNI EN ISO 9001: 2008 / UNI CEI ISO 13485:2012 CERTIFIED

H E L P I N G MILESTONE MEDICAL TECHNOLOGIES, INC.


P A T I E N T S 6475 Technology Avenue, Suite F, Kalamazoo, MI 49009 - USA
Tel: 269-488-4950 - Toll-free: 866-995-5300 - Fax: 269-488-4949
www.milestonemed.com - email: [email protected]
CAT350EN-002 • 2016-09