Hand Tachometer TM-5000/5010 Manual
Hand Tachometer TM-5000/5010 Manual
HAND TACHOMETER INSTRUCTION MANUAL Please note that misuse of this device 3. Measurement [Link]
In-contact Adaptor A t t e n t io n may lead to injury to the user or 1) Press the measurement button to turn the unit on, the LCD will then light up. When storing this device, please avoid areas which are very humid, exposed
damage to the device. to direct sunlight, high temperature, subject to vibration, dust, dirt, saline,
(Only while the measurement button is pressed, measurement is performed)
or organic gases.
Remote Sensor 2) To measure, press the measurement button for at least 1 second.
3) When measuring using the reflective tape, the " " mark will appear confirming
TM-5000/5010/E TM-5013 TM-4015 Customer Service that the photosensor is working. SPECIFICATIONS (MAIN UNIT)
4) If the measurement is out of range, the "----" mark will appear.
Photoelectric detector indicator rotational speed mode Pressing the 8 point memory data read/clear key will recall the stored data. While Rubber tip, 3 pcs.
MIN
(r/min r/s) the data are being called, MEM will blink and the memory no. is displayed on the Surface speed wheel (1/10 m)
Measurement display
linear speed mode screen. When the data from a memory no. is called out and the 8 point memory In-contact adaptor
Measurement button
While it is pressed, measurement is performed. (m/min cm/s y/min inch/s f/min) read/clear key is pressed, ALLCLR will be displayed on the screen. When TM-5014 Rubber tip, 3 pcs.
Connector for remote sensor probe Rotational / Linear speed ALLCLR is displayed on the screen, pressing the 8 point memory data input key Surface speed wheel (1/10 y)
Units Group selection key will clear the memory and the display will return to the measured value.
Remote sensor
MEAS
Measurement mode switch When the memory is being recalled and ALLCLR is displayed, not pressing any TM-4015
MAX MIN
By pressing this button, display changes as follows: (21mm diameter, maximum cable length 1m)
key for 20 seconds will return the display to the measured value.
.../min
Measurement value > MAX value > MIN value .../s Unit selection key
Connector for remote sensor probe 8-point memory data CALL
r/min r/s 5. Battery Replacement
input key RoHS
TM-5000 CLR TM-5010
The remote sensor can be used by m/min cm/s y/min
turning the slide switch inside the battery
LINE SEIKI
8-point memory data LINE SEIKI
When the mark at the left portion of the screen starts to blink, please replace
read/clear key the batteries.
box located at the back of this unit. f/min inch/s This device conforms to the following EMC regulations:
Please refer to '1.1 Installing the Batteries' for the battery replacement procedure.
TM-5000 TM-5010 Please replace all batteries with new ones.
EMI : EN50081-1
Be careful not to mix different types of batteries - i.e. manganese batteries and
EMS : EN50082-1
alkaline batteries together. Test was performed without using the remote sensor.
* The instrument cannot measure accurately after low battery indicator is This manual was last revised Dec. 8, 2022.
displayed. Please replace the battery immediately. *Subject to change without prior notice.