• 230 Vac control unit with inverter

• 230 Vac for three-phase motors with delta connections

100%
ITALY

START-S12-m Instructions and warnings for the installer

Earth -1-

230 vac power supply -2-


Rif. Pag. 12
www.nolgo.info

230 vac power supply -3-

230 Vac SIgNAl lIghT -4- automatic 230 Vac


Signal light 230 Vac switch
10/16A
230 Vac SIgNAl lIghT -5- For the connection of
a 12 Vac lamp with or
without flashing card:
Isolated contact -6- See the Page n° 12
www.ebtechnology.it

*
Isolated contact -7-

TX
TEST contacts / INTERlOCK command -8-

+
Photocells
TEST contacts / INTERlOCK command -9- working
12÷14 Vac output 800mA for accessories -10- in closing
-
12÷14 Vac output 800mA for accessories -11-
+

RX
OUT

Open limit switch -12-


Closing limit switch -13-
STOP -14-
PhOTO-A closing -15-
Safety or unfolding -16-
Open -17-
Close -18-
Start -19-
Safety Edge (8k2 / NC) -20- N.O. N.O. N.O. N.C.
Common Services Safeties -21-
Antenna Socks / Common Services Safeties -22-
Vers. firmware 1602

+ Antenna -23-

Slow down switch OPEN -24-


Slow down switch ClOSE -25-
Partial opening / Interlock input -26-
Common Services Safeties -27-
N.O. N.C. N.C.
START-S12-M_190116_VXX26_GB

Output + 12Vdc 60mA -28-


Output - 12Vdc 60mA -29-
mF1 Three-phase output for
PhOTO-A closing -30- mF2 three-phase motors and
mF3 “delta“ connections

FR1
Output for brake
FR2

2002/95/EC
* Connect this point to terminal no. 8 for the
photo-test. Otherwise connect it to the ter-
minal board no. 10
START-S12-M Technical manual

Foreword Index

This manual provides all the specific information Par. Desricption Pag.
you need to familiarize yourself with and correctly 1 Scheme of the control unit / wiring diagram 6
operate your unit. Read it very carefully when you 1.1 Description of the electrical connections 7
purchase the instrument and consult it whenever 2 Use and functions of the control panel 8
you have doubts regarding use and before perfor- 2.1 State of the control unit
ming any maintenance operations. Nologo has the 2.2 Settings and parameters
right to modify the product without previous notice. 2.3 Example how to use the MENU 9
and information
2.4 Set up a password for programming 10
Environmental protection
2.5 Cancel of the operation 11
measures 2.6 Display the number of cycles
and the speed of the motor
Information regarding the environment 2.7 Desactivation of the cycle when the control
for customers within the European panel wil be turned on
Union. European Directive EC 2002/96 3 Installation of the control unit 12
requires that units bearing this symbol 3.1 Connection of the TENSION and MOTOR
on the unit and/or on the packaging be 3.2 Connection of the lamp 230 Vac or 12 Vac
disposed of separately from undifferenti- 3.3 Pre-fl ashing time
ated urban wastes. 3.4 Connection of the ANTENNA 13
The symbol indicates that the product must not be 3.5 STOP connection
disposed of with the normal household wastes. 3.6 Connection of the 8k2 safety edge or N.C.
The owner is responsible for disposing of this prod- 3.7 Connection of the Open and Close limit switch
uct and other electrical and electronic equipment 3.8 The connection of partial opening or START 14
through specific waste collection facilities indicated
3.9 Connection of the PHOTO-BEAMS with cable
by the government or local public agencies. Correct
3.10 CONNECTION of the safety
disposal and recycling help prevent any potentially or UNFOLDING FUNCTION
negative impact on the environment and human 3.11 Connection of the PHOTO-BEAMS 15
health. To receive more detailed information re-
3.12 Connection of the photo-beam
garding disposal of your unit, we recommend that (activated when closing) with TEST
you contact the competent public agencies, the 3.13 Deactivation of the PHOTOCELL A
waste collection. 3.14 SLOW DOWN SWITCH 16
3.15 Connection of the brake and internal brake
4 ACTIVATE the single OUTPUTS 17
5 Functions 18
5.1 Logic of functions
5.2 Working time 19
5.3 Set SPEED and ACCELERATION 20
Small legend
5.4 SCHEME relation between SPEED 21
and FREQUENCY of the motor
LSO or FCA Open limit switch
6 INTERLOCK Function 22
LSC or FCC Close limit switch 7 RESET of the control unit and restore of 23
START Control to drive the gate factory default settings
PEDESTRIAN in sliding units: control partial opening 7.1 Restore factory settings
Vac (alternate current) corrente alternata 7.2 WARNING of the SETTING PARAMETERS 24
Vdc (discrete current) corrente continua 7.3 SAVE SET UP and CHECK of the parameters
NC normally closed 8 LIST of the FUNCTIONS 26
NA o NO normally open 9 Problems 29
Isolated contact isolated from power supply 10 Note 30
11 Declaration of CE conformity 31

-2-
START-S12-M Technical manual

Safety precautions

We remind that the installations of gates and automatic doors must be executed from qualified personnels
according to the norms. Before installing check the strength and mechanic part of the gate or door, check
that the mechanical stops are suitable to stop immediatelly the cycle of the gate or door even in case of faulty
limit switches or during the manual cycle. For your security we recommend to install a STOP switch when
activated it stops immediatelly the gate. The switch has a N.C. opening in case is activated (as shown in par.
no. 3.7)

Symbols and warning

Dangerous
Damage
This is a warning and if it is not
For safety reasons, protect your
respec it can provoque material
face during the connection
damage

Device under tension Read carefully the operating


manual
The installation should be done
only from professional installer Read carefully this manul before
installation and keep it for the
future
Dangerous for overheated
surface

Network filter for CE norms

FILTER-S12
Option for CE Norms

-3-
START-S12-M Technical manual

Type of installation

The control board START-S12-M can be used for Industrial rapid doors and for sliding automation with
threephase motors (delta connection) up to 3 hp with ventilation systems.

fOTO A

Rapid doors Sliding automation

Check the software version and compatibility with the operating manual

When the control unit is turn on, you can see 4 numbers in the display. This is the software number. We
suggest to check this number with the version on the manual. (see pic).

CODE

1602 START-S12-m
Vers. firmware 1602

! Check that the number


on the display correspond
to the firmware
on the operating manual.

-4-
START-S12-M Technical manual

1 Scheme of the control unit


WARNINg!
LED POWER ON
We remind you that the safety devices, accessories should be installed
Indicates the
when the control unit is not powered.
network power

1 2 3 4 5
6 7
FUSE 1
10 A

8 9 10 11

24 25 26 27

mF1

mF2

mF3

FR1
FR2
12 13 14 15 16 17 18 19 20 21 22 23
28 29 30

P1 P2 P3 Set the control unit mF1-2-3 Three-phases output for 230Vac motors delta connection
DIP not used FR1-2 Output for brake motor
JP1 Connector for temperature sensor LED WARNINg Indicates that the capacitors are still charged, be-
F1 fuses protection motor and power: 10A fore taking the central wait until the LED turns off.
F2 fused protection terminal boards (4, 5): 1.6A
F3 fuses for power supply for accessories and safeties: 200mA

The red led in the input LSO-LSC-STOP-PhOTO-UNFOLDINg EDgE are always lit on
The green led in the inputs OPEN-CLOSE-START are normally lit on
LSO LSC STOP PhOTO UNFOLDINg OPEN CLOSE START

WARNINg: If the inputs are desactivated from display with S13, S14, S15, S16, S17 red leds are SWITChED OFF

-5-
START-S12-M Technical manual

Recommended NETWORK FILTER

wiring
diagram

fIlTER RINg

CABlE MOTOR
OUTPUT
1 TURN ElECTRICAl
gROUND BAR

ShIElDED
CABlE
ENgINE

MOTOR
TERMINAl
MOTOR BOARD

-6-
START-S12-M Technical manual

1.1 Description of the electrical connections

Earth 1 Earth
230 Vac (N) 2 230 Vac 50Hz, power supply, neutral
230 Vac (L) 3 230 Vac 50Hz, power supply, phase

Signal light 4 230 Vac Signal light


5 Max power 40 W

6 For the connection of a 12 Vac lamp or 230Vac signal ligth:


Signal light 7 See the par 3.2, page number 12

Test 8 Isolated contact for TEST / Interlock command


Test 9 Isolated contact for TEST / Interlock command
Out 12 Vac 10 12÷14 Vac output 800mA for accessories
Out 12 Vac 11 12÷14 Vac output 800mA for accessories

LSO 12 Open limit switch


LSC 13 Closing limit switch
Stop 14 STOP
Photo A 15 Photo-A closing
Safety edge 16 Safety or unfolding
Open 17 OPEN
Close 18 CLOSE
Start 19 START
Costa 20 SAFETY edge - NC / 8k2 contact
Common 21 Common Services Safeties
Common 22 Antenna Socks / Common-Services-Safeties
+ Antenna 23 + Antenna

Switch Slow OP 24 Slow down switch OPEN


Switch Slow CL 25 Slow down switch CLOSE
Pedestrian 26 Partial opening / Interlock input
Common 27 Common Services Safeties

Out + 12 Vdc 28 Output + 12Vdc 60mA


Out - 12 Vdc 29 Output - 12Vdc 60mA
Photo A 30 Photo-A closing

-7-
START-S12-M Technical manual

2 Use and functions of the control panel


START-S12-M has a display for a simple and fast programming. The menu has been designed for a clear
and fast set up of the working time and the logic of the control unit. You can set up the control unit only when
the door is closed.

2.1 State of the control unit


If you don’t press any button, the display shows the position and the temperature of the heat sink.

P.Fcc t23c
In this case the door is with closing limit switch and
that the heat temperature is 23°C.

2.2 Settings and parameters

ACCESS TO ThE fUNCTIONS


Press P1 when the gate is closed
P1

SELECTION Of ThE LETTER ADJUSTMENT


Press button P2 and P3 to select the group
and press P1 to confirm.
P2 - UP P3 - DOWN P1 - OK

- t-
Set up T
Set up of the Time
programming
- S- Set up S
Logic of the control unit

- L-
Set up L
Set up of the programm
(Speed, power...)
- r- Set up R
Activation of the outputs
Displays information

- E-
about the control unit
Set up E
Back to the standard functions

SELECTION OF NUMBER SET UP


Press P2 and P3 to select the set up
Press P1 to confirm
P2 - UP P3 - DOWN P1 - OK

gO BACk SELf-RESET
+ To go back to the previous If the control unit is not used for more
group press P2 and P3 than one minute, the control unit go out
P2 P3
from the programming saving
programs and all changes.

-8-
START-S12-M Technical manual

2.3 Example how to use the MENU and information

You can read the information through a display: you can read if it is working properly, the manoeuvre counter
and the sink temperature. Some information can be shown only on the R function (see Chapter no.4)

- t- SYmBOlS

P1
Access to
the MENU
Press and Keep pressed Release
release

P2
- L- 1st Press

- S-
DOWN
2nd Press

- r- 3rd Press

P1 confirm

In the function R if you press P1, you can choose the group function: first select P2 and P3 and then confirm
with P1. Now you can go to the function R07, R08, R09 and R10

DOWN r 07 P1
Show the tension
in the capacitors
P1

r 08
P2
Show temperature
of the IgBT
P1 P1

r 09
Show the resistive
value in the
Safety edge input
P1 (terminal board no.20) P1

P3

r 10
UP Show the
cycle counters
(point indicated the
P1 thousands) P1

-9-
START-S12-M Technical manual

2.4 Set up a password for programming

To save all changes it is possible to select a password of 4 numbers. To activate this function make as follow:

• PASSWORD ACTIVATION:
Press P1, P2 and P3 in the function S32 and then confirm with P1.

- t- P2
- S-
P1
Access to the menu 2nd press

P1 confirm

In the function S if you press P1, you can choose the group function: first select P2, now you can go to the
function S32 and then confirm with P1.

S 01
• INSERT PASSWORD
Choose the first number with the buttons P2 and P3 then
confirm with P1. The same procedure applies to the other
digits.

0---
P2 finished entering the 4 digit. Press P1 to confirm. To can-
cel press P1, within 10 seconds. Otherwise, the next ac-
cess will be required the security code.

S 32
P1 - OK
! Pay attention in case you forget
the password it is not possible to
enter in control board as well.

• DEACTIVATION OF ThE PASSWORD

S 33
If you select the fucntion no. S33 you can cancel the password.
Wait 10 seconds to confi rm the operation.

P1 - OK

-10-
START-S12-M Technical manual

2.5 Cancel of the operation

When you confirm the operation you can read the following message to cancel the operation. If you press P1
in 10 seconds, this operation will be cancelled.

P110 P109 P100


2.6 Display the number of cycles and the speed of the motor

• CYCLE COuNTER • MOTOR SPEED

It is possible to show the number of Press P1 when the door is


cycles even pressing P3 (expressed in open, the display shows the
ten cycles) SPEED of the MOTOR
P3 P1

The counter counts up to 999’999 openings. The


display shows the first 4 most significant digits.

344.2
If you read these number, it
means that the installation
has made 344200 cycles.

2.7 Desactivation of the cycle when the control panel wil be turned on

When the tension has been interrupted and you turn on the control board again it will make a new cycle. To
exclude this operation make as follow:

DESACTIVATE THE COMPLETE CYCLE Of ThE CYCLE fUNCTION


WhEN ThE TENSION hAS BEEN INTERRUPTED:
keep pressed P1 when turns on.
P1

-11-
START-S12-M Technical manual

3 Installation of the control unit

3.1 Connection of the TENSION and MOTOR POWER SUPPLY

1 2 3 • The control unit is ThREE PhASE mOTOR


equipped with a net- “DELTA” CONNECTION
work filter
It is recommended to use
We recommend: shielded cables
mF3
• Install an automatic
N L switch 10/16A
230 Vac
• Check the network
power: 230 Vac:
-5% +10% M
mF1 mF2

3.2 Connection of the lamp 230 Vac or 12 Vac

It is shown the connection of a 230V lamp with or • SET UP OF ThE LIghTINg


without flashing card. In case the lamp has no flashing card, set S12 in 1:
LAmP

S12
230 Vac flAShINg
4 5 6 7 1 - Activated (standard)
0 - Deactivated

• LAmP IN PAUSE TImE


To activate the function lamp in pause TIME, set
S05 as shown:

S 05
lAMP IN PAUSE
It is shown the connection of a 12 Vac lamp with or
1 - Activated
without flashing card. 0 - Deactivated (standard)

10 11 6 7 3.3 Pre-flashing time


LAmP
12 Vac
It is possible to increase or reduce the time of pre-flashing
when the door is closed or open, make as follow with T07
and T08:

t 07
PRE -flAS hIN g TIME WhEN
ThE DOOR IS ClOSED
from 0 to 10 s
Standard value 0.5 s

t 08
PRE-flAShINg TIME
WhEN ThE DOOR IS OPEN
from 0 to 10 s
Standard value 2 s

-12-
START-S12-M Technical manual

3.4 Connection of the ANTENNA 3.5 STOP connection


In case the antenna is only a cable of 17cm for 433.92Mhz,
connect it to the terminal board no. 23. 12 13 14 15 16 17 18 19 20 21 22 23

20 21 22 23

Button: Stop until a new command


Switch: it keep the automation stopped until a new
command

S 15
STOP
1 - Activated
0 - Deactivated

The connection of the safety devices is prevued


with a button or a normally closed contact
More devices should be connected in parallel.

3.6 Connection of the 8k2 safety edge or N.C. contact

12 13 14 15 16 17 18 19 20 21 22 23 Connect the safety edge at terminal board no. 20 and 21

S 22
SAFETY EDGE
1 - Activated (Standard)
0 - Deactivated

S 38
SAFETY EDGE contact
0 - NC contact
1 - 8K2 contact (Standard)

3.7 Connection of the Open and Close limit switch

The picture shows the connection of both limit switches but you can connect it separately. You can use only
LSO or only LSC.

S 13
LSO
12 13 14 15 16 17 18 19 20 21 22 23
1 - Activated
0 - Deactivated

S 14
LSC
1 - Activated

!
0 - Deactivated
OPEN CLOSE
N.C. N.C.

LIMIT If the input LSO & LSC


SWITCHES
is not used, set S13 & S14 in 0

-13-
START-S12-M Technical manual

3.8 The connection of PARTIAL OPENING or START

12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Partial
OPENINg

START The connection of


a START command
can be done with
a button or with a
N.O. contact. When
more devices are The connection of PARTIAL OPENINg
available, connect can be done with a button or a normally
them in parallel. open contact.

It is possible to connect a timer in the terminal board no. 19 and 21 to program the opening time of the gates.
The contact of the timer should be normally open (N.O.) and it should be closed for all the time the gate is
open. If the conncection of opening command is available in the terminal board no 19, connect it in parallel.

3.9 Connection of the PHOTO-BEAMS with cable (only when closing)


The terminal boards 28-29-30 are available for the connection of the photo-beams with cable like IRPA 1/
SENSOR-3DD. You can see a standard installation:
RX TX
28 29 30

!
Output + 12Vdc 60mA -28-
Output - 12Vdc 60mA -29-
PHOTO A when closing -30-

IRPA 1 / SENSOR-3DD Please read the manual


IRPA1 / SENSOR-3DD

3.10 CONNECTION of the safety or UNFOLDING FUNCTION


In case the control units is installed in rapid-rise-doors is possible to connect photobeam for unfolding the
curtain. In case the intervention of safeties, the doors stops and reverse the cycle of 1.5sec.

S 17
12 13 14 15 16 17 18 19 20 21 22 23 8 9 10 11 Input UNFOLDING
1 - Activated
0 - Deactivated

!
12 Vac

RX TX
If the input is not used,
set S17 at 0

The connection of more safety devices can be


done with each button or a N.C. contact. More
safety devices should be connected in serial.

NC Contact

-14-
START-S12-M Technical manual

3.11 Connection of the PHOTO-BEAMS (only when closing)

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 The contact of the receiver should be:


- Isolated (isolated from tensions)
- Normally closed

TX
RX

! If the input PHOTO


is not used, set S16 in 0

12 Vac

NC Contact

3.12 Connection of the photo-beam (activated when closing) with TEST

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 The TEST of the photo-beam works only if the


photo-beams are installed properly. The control
unit will check all connections before opening!

TX
In case the photo-beam are not working pro-
RX perlym the control unit will lit on for 5 seconds
and the gate is not moving.

If you go back to function without TEST, do the


connection as in Par. 3.08 and put in 0 the S06
and S09 (deactivate if are inputs are not in test)
12 Vac

NC Contact

To activate the TEST set 1 in the PHOTO-A:

S 09 S 06
TEST in PHOTO OUTPUT TEST in the INPUT
1 - Activated safeties
0 - Deactivated 1 - Activated
0 - Deactivated

3.13 Deactivation of the PHOTOCELL A when the gate is closing

S 03
Photocell A deactivated If you set S03 it deactivates the PHOTO A after in-
1 - Activated tervention of slow down LS. If S03 is 1 the time of
0 - Deactivated function T11 is not considered

-15-
START-S12-M Technical manual

3.14 SLOW DOWN SWITCH


For the beginning of the slow down it is possible to connect the switch OPEN and CLOSE. Connect the
switch to terminal board no. 24-25-27 as shown in the pic. The switches are not installed, the slow down can
be programmed with T03 (open) and T04 (close).

24 25 26 27

Common
Switch

OPEN CLOSE

S 20 S 21
Switch input when opening Switch input when CLOSING
1 - Activated (Standard) 1 - Activated (Standard)
0 - Deactivated 0 - Deactivated

3.15 Connection of the brake (FR1-FR2) and internal brake

Pay attention when you connect the brake and pay attention of the polarity. Program with S19 according to
the type of brake:

S 19
POLARITY OUTPUT OF THE BRAKE
0 - brake deactivate with tension (Standard)
1 - brake activate with tension

You can activate the INTERNAL BRAKE (S37), activating this function, the internal brake is activated for 2
seconds after engine shutdown.

S 37
INTERNALE BRAKE
1 - light decelaration 5 - no aceleration, no brake
2-
3- 6 - light braking
4 - high deceleration 7-
8-
9 - high braking

-16-
START-S12-M Technical manual

4 ACTIVATE the single OUTPUTS


START-S12-M can open and close separately and the outputs for lamps and test. This is useful in case you
want to check the single outputs.

- t- - L- P2 - 1st press

- S-
P1 P2
Access to the functions
P2 - 2nd press
SYmBOlS

Press and
release
Keep pressed Release
- r- P2 - 3td press

In the function R if you press P1, you can choose the subfunction group fun-
ction: first select P2 and P3 and then confirm with P1. Now you can go to the
P1 confirm
function R01, R02, R03 ...

r 01
OPEN
with set up
DOWN acceleration
P1 P1

r 02
CLOSE
P2 with set up
P1 acceleration P1

r 03 P1
OPENINg
with slow down
P1

r 04 P1
CLOSINg
with slow down
P1

P3 UP
r 05 P1
Activate the LIghT
P1

r 06 P1
ACTIVATE
the TEST output
P1

r 11 P1
ACTIVATE
the BRAkE output
P1

-17-
START-S12-M Technical manual

5 Functions

5.1 Logic of functions

Imp. N° Val. Functions Description

S 01 1 Signal Reverse
By each START command inverts: OPEN-CLOSE
It recloses automatically

2 Automatic
The START command can open or recharge the pause
time. It recloses automatically

3 Bistable function
By each START command it follows: open-stop-close-
stop-open... It doesn’t recloses automatically
Stable function with
4 automatic reclosing
after pause time
By each START command it opens-stops-closes-
stops-opens... It recloses automatically after pause time

5 Signal reverse
+ Dead-man function
Same as function S01 - 1
OPEN and CLOSE with “Dead-man function“ function

6 Collective use
+ Dead-man function
Same as function S01 - 2
OPEN and CLOSE with “Dead-man function“ function

7 Bistable function
+ Dead-man function
Same as function S01 - 3
OPEN and CLOSE with “Dead-man function“ function
Bistable function with

8 automatic reclosing Same as function S01 - 4


after pause time OPEN and CLOSE with “Dead-man function“ function
+ Dead-man function

Reclosing when
S 02 1 turning on
(Standard value 0)
Complete open and close. ONLY when the tension has
been interrupted when the gate is open.

S 04 1 It detects the passage The access will be detected from the photo-beams, if
(Standard value 0) S07 is 0 the pause time is 2sec.
It reverse in case
S 07 1 of access
(Standard value 1)
Put S04 in 1. When the gate is opening, the control unit
inverts the direction and close.

1 - Function as limit switch


Logic of the 2 - Function as STOP

S 08 2 Obstacle Detection
(Standard value 2)
3 - Function as REVERSE and then STOP
4 - Automatic adjustment of motor torque, function L09 choose
the right function according to the motor installed
(not for sliding gates or safety devices).

-18-
START-S12-M Technical manual

5.2 Working time


You can see how to program the control unit with T function:

T 01

T 12
T 03

T 02

T 04

T 11

t=0s

SET STANDARD
DESCRIPTION
UP - seconds -
T 01 Set up the fully opening time of the door/gate value from 0,1 s 4,0
T 02 Set up the opening time of partial opening value from 0,1 s 3,0
T 03 Set up the start position of OPEN decelerating time value from 0,1 s 2,0
T 04 Set up START position of the CLOSING deceleration time value from 0,1 s 1,0
Set up start position of deactivation of the photocelle.
T 11 value from 0,1 s 0,5
It is not considered if S03 is set in 1
Deactivation Time of the input SAFETY EDGE (term.S16) from starting
of LSO. This function is useful in case of anti-folding to avoid the unroll
T 12 1,0
of the curtain which can temporary cover the photocell and the door
will start opening again.

-19-
START-S12-M Technical manual

5.3 Set SPEED and ACCELERATION

Are now given the parameters that allow you to set SPEED, ACCELERATION and ABSORPTION:

Set up Description Values Accepted Standard

L 01 Minimum speed OPENING from 1 to 200 30

L 02 Minimum speed CLOSING from 1 to 200 20

L 03 Maximum Speed OPENING from 1 to 200 80

L 04 Maximum speed CLOSING from 1 to 200 40

L 05 OPENING acceleration from 1 to 99 8

L 06 CLOSING acceleration from 1 to 99 8

L 07 OPENING deceleration from 0 to 25 8

L 08 CLOSING deceleration from 0 to 25 8

L 09 Motor absorption in case of STOP Ampere 5,0

L 10 Motor absorption in case of problems Ampere 7,0

L 11 Power in the BRAKE OUTPUT from 1 to 70 50

-20-
START-S12-M Technical manual

5.4 SCHEME relation between SPEED and FREQUENCY of the motor

Here is the relation between speed and frequency of the motor:

Speed FREQUENCY Speed FREQUENCY


setting [Hz] setting [Hz]

1 12 105 64.50
5 14.50 110 67.00
10 17.00 115 69.50
15 19.50 120 72.00
20 22.00 125 74.50
25 24.50 130 77.00
30 27.00 135 79.50
35 29.50 140 82.00
40 32.00 145 84.50
45 34.50 150 87.00
50 37.00 155 89.50
55 39.50 160 92.00
60 42.00 165 94.50
65 44.50 170 97.00
70 47.50 175 99.50
75 49.50 180 102.00
80 52.00 185 104.50
85 54.50 190 107.00
90 57.00 195 109.50
95 59.50 200 112.00
100 62.00

-21-
START-S12-M Technical manual

6 INTERLOCK Function

WARNINg: The TEST function and the PARTIAL OPENINg are not available in this function!!!
To activate the INTERLOCK function use function S35 and connect the 2 control units.

CONTROL BOARD A
When one con-
trol uniti is wor-
king, you can
see in the di-
S 35
splay FBUSS, INTERLOCK fUNCTION
and it cannot ac- 1 - Activated
cept other com- 0 - Deactivated
mands.

CONTROl
BOARD A
8 9 10 11

CONTROl
BOARD B
24 25 26 27

CONTROL BOARD B

CONTROl
BOARD B
8 9 10 11

CONTROl
BOARD A
24 25 26 27

-22-
START-S12-M Technical manual

7 RESET of the control unit and restore of factory default settings

The control panel allows users to restore parameters to their standard values (see par. 8) also allows you set
up the default factory settings of rapid doors (4.5 m - 3.5 m - 2.5 m) and sliding gates.

7.1 Restore factory settings


Checking those paramenter of the parameters (Chapter no.8), yuo can look the set up during the RESET of
the control unit. Select the paragraph S18 as shown.

P1
- t- P2
- S-
Access to the functions 2nd press

S 01
P1 confirm

P2

S 18 P110
Wait 10 seconds, otherwise, if you press
P1 in 10 seconds, this operation will be

!
cancelled.
P1 - OK

WARNINg:
This operation
cancel all settings

For standard values see table at pag no. 27 and following.

-23-
START-S12-M Technical manual

7.2 WARNING of the SETTING PARAMETERS

The first paramenters are indicated for high speed doors, depending on the height of the door. The paramen-
ter no.4 is for industrial sliding gates.

S 27 S 28 S 29
Set up P1 Set up P1 Set up P1
STANDARD 1 STANDARD 2 STANDARD 3

STANDARD 1 STANDARD 2 STANDARD 3


(High-speed doors h4,5m) (High-speed doors h3,5m) (High-speed doors h2,5m)
Set up Val. Set up Val. Set up Val.
T01 4,5 T01 3,5 T01 2,5
T02 2,5 T02 2,5 T02 2,0
T03 3,0 T03 2,0 T03 1,0
T04 1,5 T04 1,0 T04 0,5
T05 3,0 T05 3,0 T05 3,0
T06 3,0 T06 3,0 T06 3,0
T07 0,0 T07 0,0 T07 0,0
T08 0,0 T08 0,0 T08 0,0
T09 0,0 T09 0,0 T09 0,0
T10 5,5 T10 4,5 T10 3,5
T11 0,5 T11 0,5 T11 0,5
T12 0,0 T12 0,0 T12 0,0
T13 0,1 T13 0,1 T13 0,1
T14 0,1 T14 0,1 T14 0,1
T15 0,0 T15 0,0 T15 0,0
T16 0,0 T16 0,0 T16 0,0
T17 12 T17 12 T17 12

STANDARD 1 - 2 - 3 (These parameters are the same for all 3 set up)
Set up Val. Set up Val. Set up Val.
L01 20 (13 Hz) L05 8 L09 11 [A]
L02 20 (13 Hz) L06 8 L10 15 [A]
L03 80 (50 Hz) L07 8 L11 50
L04 40 (25 Hz) L08 8

-24-
START-S12-M Technical manual

S 30 STANDARD 4 (sliding gates)


Set up Val. Set up Val.
Set up P1 T01 20,0 L01 30 (19 Hz)
STANDARD 4 T02 10,0 L02 30 (19 Hz)
T03 17,0 L03 80 (50 Hz)
T04 3,0 L04 80 (50 Hz)
T05 10,0 L05 4
fOTO A

fOTO A2
T06 10,0 L06 4
T07 2,0 L07 4
for sliding gates T08 2,0 L08 4
T09 120,0 L09 3,0 [A]
T10 5,0 L10 5,0 [A]
T11 0,0 L11 70
T12 0,0
T13 1
T14 10
T15 0
T16 0

7.3 SAVE SET UP and CHECK of the PARAMETERS

STARTS12 has 2 memory slots saving all manually set up and you can check it again. See how to check the
set up with functions S23, S24, S25, S26. Once all parameters are set up, it is possible to change.

Thanks of the 2 memory slots, it is possible to save and check 2 differents set up.

• MEMORY 1 (slot 1) • MEMORY 2 (slot 2)

S 23 S 24
Press P1 Press P1
Save all set up Save all set up
MEMORY 1 MEMORY 2

S 25 S 26
Press P1 Press P1
Charge set up of Charge set up of
MEMORY 1 MEMORY 2

-25-
START-S12-M Technical manual

8 LIST of the FUNCTIONS


Group functions “T”
SET VALUES STANDARD MEMO
DESCRIPTION
UP ACCEPTED - seconds -

T 01 Complete opening cycle time step from 0,1 s 4,0


T 02 Partial opening time step from 0,1 s 3,0
T 03 Set up deceleration by opening step from 0,1 s 2,0
T 04 Set up deceleration by closing step from 0,1 s 1,0
T 05 Pause time for START or OPEN step from 0,5 s from 2 to 127.5 s 2,0
T 06 Pause time for PARTIAL OPENING step from 0,5 s from 2 to 127.5 s 5,0
T 07 PRE-LIGHTING time by opening step from 0,5 s from 2 to 127 s 0,5
T 08 PRE-LIGHTING time by closing step from 0,5 s from 2 to 127 s 2,0
T 09 (Not used)
T 10 Time to research of the limit switch step from 0,1 s 5,0
Stop the detection of input of the photo-beam.
T 11 step from 0,1 s 0,5
Not considered if S03 is set 1
T 12 Time to stp to detecte the SAFETY EDEGE INPUT
step from 0,5 s 1,0
(terminal board. 16)
Time block the check of the absorption of the motor
T 13 step from 0,1 s from 0 to 2 s 0,2
when the gate is opening or closing
T 14 Pause time of reverse of the direction of the motor step from 0,1 s from 0 to 2 s 0,1
T 15 STOP of the motor after detecting the LSO step from 0,1 s from 0 to 3 s 0s
T 16 Time of delay of the motor when detecting the LSC step from 0,1 s from 0 to 3 s 0s
Lead time on the release of the brake before starting
T 17 from 0 to 20 12
the engine (in tenths of seconds)

Group functions “L”


SET VALUES STANDARD
DESCRIPTION MEMO
UP ACCEPTED - seconds -

L 01 Minimum opening speed from 1 to 200 30


L 02 Minimum closing speed from 1 to 200 20
L 03 Maximum opening speed from 1 to 200 80
L 04 Maximum closing speed from 1 to 200 40
L 05 Opening acceleration from 1 a 99 8
L 06 Closing acceleration from 1 a 99 8
L 07 Opening deceleration from 0 to 25 8
L 08 Closing deceleration from 0 to 25 8
in Ampere
L 09 Maximum absorption of the motor to STOP the door 5,0
from 0,5 to 15,5
in Ampere
L 10 Maximum absorption of the motor in case of trouble 7,0
from 0,5 to 15,5
L 11 Power of the output BRAKE from 0 to 70 50

-26-
START-S12-M Technical manual

Group functions “S”


SET VALUES
DESCRIPTION STANDARD MEMO
UP ACCEPTED

S 01 Logic of the motor: from 1 to 8 1

1 - Fast reverse
2 - Collective use
3 - Bistable function
4 - Bistable function with automatic reclosing
5 - Fast reversing and “Dead’s man“ function
6 - Collective use and “Dead’s man function
7 - Bistable funciton and “Dead’s man“ function
8 - Bistable function with automatic reclosing
and “Dead’s man“ function

S 02 Opening-closing cycle when the door is not closed 0 Off - 1 On 0

S 03 Deactivate the input PHOTO A


0 Deactivated - 1 Activated 0
after intervention of the slow down LSC
S 04 Passage Detection 0 Off - 1 On 0
S 05 Signal light in pause time 0 Off - 1 On 0
S 06 Activation TEST in the safeties inputs 0 Off - 1 On 0
S 07 Logic passage detection 0 Off - 1 On 0
S 08 Logic of the Obstacle Detection 1 - Considered as limit switch 2
2 - Considered as STOP
3 - Reverse motor of 2 sec,
at min.speed
4 - According to the set up of
function L09 and according to
the motor (not for sliding gates
of safety devices)

S 09 Activate the TEST in the input PHOTOCELL 0 Off - 1 On 0


S 10 Activate the Test in the SAFETY EDGE input 0 Off - 1 On 0
S 11 Activate the TEST in the input STOP 0 Off - 1 On 0
S 12 Activate the flashing in the signal light input 0 Off - 1 On 1
S 13 Activate the input LSO 0 Off - 1 On 1
S 14 Activate the input LSC 0 Off - 1 On 1
S 15 Activate STOP input 0 Off - 1 On 1
S 16 Activate the PHOTOCELL by closing 0 Off - 1 On 1
S 17 Activate the input ANTIFOLDING 0 Off - 1 On 1
S 18 Reset of the control unit at factory’s settings
0 - deactivated with tension
S 19 Polarity of the brake output 0
1 - brake activated with tension
S 20 Activated the input SWITCH for opening slowing down 0 Off - 1 On 1

S 21 Activate the input swicht for CLOSING slowing down 0 Off - 1 On 1

S 22 Activate the input for SAFETY EDGE (terminal 20-21) 0 Deactivated - 1 Activated 1

-27-
START-S12-M Technical manual

SET
DESCRIPTION VALUES ACCEPTED STANDARD MEMO
UP
S 23 Copy set up of memory 1

S 24 Copy set up of memory 2

S 25 Charge the set up of memory 1

S 26 Charge the set up of memory 2

S 27 Charge the standard set up 1

S 28 Charge the standard set up 2

S 29 Charge the standard set up 3

S 30 Charge the standard set up 4

S 31 Charge the standard set up 5


Activate of a password to set up with a code of 4 num-
S 32
bers. Put the new code and let the time goes.
You can deactive the access of the set up
S 33
with a password
Activation of the security closing
S 34 0 deactivated - 1 activated 0
after intervention of the edge (20-21)

S 35 Activation of the INTERLOCK function 0 deactivated - 1 activated 0

S 36 Check of the input UNFOLDING (terminal board no.16) 0 deactivated - 1 activated 0

1= light acceleration
4 = heavy acceleration
Integrated electric brake
S 37 5=neither acceleration nor braking 0
(activated for 2 seconds after motor stopping)
6= light braking
9= heavy braking
S 38 Safety edge - contact terminal board no.20-21 0: N.C. contact - 1: 8K2 contact 1

Group functions “R”

SET UP DESCRIPTION
R 01 Activate Opening until P1 has been released with acceleration set up
R 02 Activate CLOSING until P1 has been released with acceleration set up
R 03 Activate the OPENING until P1 has been released with slow down acceleration
R 04 Activate CLOSING until P1 has been released with slow down set up
R 05 Activate LIGHT/SIGNAL LIGHTH until P1 has been released
R 06 Activate TEST output until P1 has been released
R 07 Display the tension of the capacitors until P1 has been released
R 08 Display temperature of the IGBT until P1 has been released
R 09 Display the resistive value in the SAFETY EDGE input (terminal board no.20) until P1 has been released
R 10 Display the number of cycles number of cycles until P1 has been released (point indicated the thousands)
R 11 Activate the brake output

-28-
START-S12-M Technical manual

9 Problems
Here are listed some functions issue indicated in the display. You can see the causes and the procedure to
solve the issue.
Problem Description Solution

Er01 OVERVOLT on vbus


There is a tension of 240 Vac in the
capacitors. Check the network tension.

Er02
The overcurrent level of programm L10
OVERCURRENT in the MOTOR has been exceeded. If necessary incre-
ase the value.

Er03 Tension in the capacitors too low The tension in the capacitors is too
low. Check the network tension.

Er04
The control unit has an absorption of
Absorption at 1.5 A more than 1,5A even if the motor is not
when the motor is not working working. Check the accessories and
the motor.

Er05 Security code not correct


Code not correct.
Try a new code.

Er06 Exceeded temperature


of the spendthrift IGBT
Wait until the temperature in the
spendthrift is reduced.

Er07 Er17
Er27 Er67 Signal error of the encoder Check the encoder connections

Er77

Er57
The barriers doesn’t detect the cycle
of the door when the motor is powe- Check the curtains
ring.

-29-
START-S12-M Technical manual

.................................................................................................
10 Note
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
.................................................................................................
-30-
START-S12-M Technical manual

11 Declaration of CE conformity
(according to EC Directive 2006/42, Attachment II, part 1, ses. A)
Company: EB TECHNOLOGY SRL
The undersigned Ernestino Bandera, Address: Corso Sempione 172/5
Administrator 21052 Busto Arsizio VA Italy
Product’s name: START-S12-M
DECLARES THAT: Centrale Inverter 230Vac

THE PRODUCT COMPLIES with what is outlined in the European Community directive:

EC DIRECTIVE 2006/42 ISSUED BY THE EUROPEAN PARLIAMENT AND


2006/42/CE COUNCIL on may 17, 2006 harmonizing the legislation of the member countries
regarding machinery.

Reference: Attachment II, part 1, ses. A (EC Declaration of Conformity issued by the manufacturer).

THE PRODUCT COMPLIES with what is outlined in the European Community directives:

EEC DIRECTIVE 2006/95 ISSUED BY THE EUROPEAN COUNCIL on December


2006/95/CE 12, 2006 harmonizing the legislation of the member countries regarding electric
materials for use within certain voltage limits

Reference to harmonized standards: EN 60335-1

EEC DIRECTIVE 2004/108/CE ISSUED BY THE EUROPEAN COUNCIL on


2004/108/CE December 15, 2004, harmonizing the legislation of the member countries regarding
electromagnetic compatibility.

Reference to harmonized standards: EN 61000-6-2 EN 61000-6-3

with the essential requirements of article 3 of the following


IL PRODOTTO E’ CONFORME European Community Directive, for the use for which the
product is designede

EC DIRECTIVE 1999/5 ISSUED BY THE EUROPEAN PARLIAMENT AND


1999/5/CE COUNCIL on March 9, 1999 regarding wireless units and telecommunications
terminals and their reciprocal recognition

Reference to harmonized standards: ETSI EN 300 220-3 ETSI EN 301 489-1 ETSI EN 301 489-3

The directive 2006/42/CE remind that it is not allowed the function of the product until the machine, for which
the product is included, is not indentify and declared conformed to the 2006/42/CE directive.

Dairago, 1 february 2012


The Administrator
EB TECHNOLOGY S.r.l. NOLOGO S.r.l. Ernestino Bandera
Corso Sempione 172/5, via Cesare Cantù 26,
21052 Busto Arsizio VA Italy 20020 Villa Cortese MI Italy
tel. +39 0331.430457
fax.+39 0331.432496
[email protected]
www.ebtechnology.it [email protected]
www.nologo.info

-31-
START-S12-M Technical manual

DICHIARAZIONE DI CONFORMITA’ DECLARATION OF CONFORMITY DÉCLARATION DE CONFORMITÉ

Il sottoscritto, rappresentante il seguente The undersigned, representative of the fol- Le soussigné, représentant du constructeur
costruttore, dichiara che l’apparecchio de- lowing manifacturer, hereby certifies that the suivant certifie que les appareils ci-dessus
nominato equipment known as référencés

START-S12-M START-S12-M START-S12-M


risulta conforme a tutte le norme tecniche complies with all technical requirements sont conformes à toutes les normes tech-
relative al prodotto entro il campo di applica- concerning this product within the domain of niques relativement au produit dans le do-
bilità delle Direttive Comunitarie 2006/42/CE, application of the EC Directives 2006/42/CE, maine d’application des Directives Europée-
2006/95/CE, 2004/108/CE e 99/5/CEE 2006/95/CE, 2004/108/CE and 99/5/CEE nnes 2006/42/CE, 2006/95/CE, 2004/108/CE
et 99/5/CEE
Sono state eseguite tutte le necessarie prove All necessary radiofrequency tests have been
di radiofrequenza performed Toutes les essais de radiofréquence néces-
saires ont été effectués

EB TECHNOLOGY SRL EB TECHNOLOGY SRL EB TECHNOLOGY SRL


Corso Sempione 172/5 Corso Sempione 172/5 Corso Sempione 172/5
21052 Busto Arsizio (Va) 21052 Busto Arsizio (Va) 21052 Busto Arsizio (Va)
Italia Italia Italia
Questa dichiarazione viene emessa sotto la This declaration is rendered under the man- Cette déclaration est présentée sous la seule
sola responsabilità del costruttore e, se ap- ifactu-rer’s sole responsability, and if appli- responsabilié du constructeur et, si applica-
plicabile, del suo rappresentante autorizzato. cable, under responsability of his authorized ble, de son représentant autorisé.
representative.

Italia, 01/02/2012 Italia, 01/02/2012 Italia, 01/02/2012

Amministratore Administrator Administrateur

KONFORMITÄTSZERTIFIKAT DECLARACIÓN DE CONFORMIDAD DECLARACÃO DE CONFORMIDADE

Der Unterzeichner bescheinigt, dass das El abajo firmante, representante el fabricante O abaixo-assinado, represendo o seguinte
Produkt siguiente, declara que el equipo denominado construtor declara que o aparelho denomi-
nado

START-S12-M START-S12-M START-S12-M


allen technischen Produktegesetzen, laut den es conforme con todas las normas técnicas é conforme a todas as normas técnicas relati-
Europäische Gesetzen 2006/42/CE, 2006/95/ correspondientes al producto en el campo vas ao produto dentro o campo de aplicabili-
CE, 2004/108/CE e 99/5/CEE, entspricht. de aplicación de las Directivas Comunitarias dade das Diretivas Comunitarias 2006/42/CE,
2006/42/CE, 2006/95/CE, 2004/108/CE y 2006/95/CE, 2004/108/CE e 99/5/CEE
Alle Radiofrequenzprüfungen haben bei der 99/5/CEE
nachstehenden Firma stattgefunden: Foram executadas todas as necessárias pro-
Han sido realizadas todas las necesarias vas de rádio frequência.
pruebas de radiofrequencia.
EB TECHNOLOGY SRL EB TECHNOLOGY SRL
Corso Sempione 172/5 EB TECHNOLOGY SRL Corso Sempione 172/5
21052 Busto Arsizio (Va) Corso Sempione 172/5 21052 Busto Arsizio (Va)
Italia 21052 Busto Arsizio (Va) Italia
Italia
Diese Bescheinigung wird unter der alleinigen Esta declaração verm emitida somente com a
Verantwortung des Herstellers ausgestellt Esta declaración se expide bajo la exclusiva responsabilidade do construtor e, se aplicáv-
und dort woanwenbar, auch unter der des responsabilidad del fabricante y, si de apli- el, do seu representante autorizado.
befugten Vertreters. cación, de su representante autorizado.

Italia, 01/02/2012 Italia, 01/02/2012 Italia, 01/02/2012

Verwalter Administrador Administrador

-32-