100% found this document useful (1 vote)
689 views34 pages

Gomti Nagar - Structural DBR - Air Concourse

structural DBR

Uploaded by

Kumar Atray
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
689 views34 pages

Gomti Nagar - Structural DBR - Air Concourse

structural DBR

Uploaded by

Kumar Atray
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
A onstructure BLHASHYRP Construct PROJECT NAME: OF GOMTI NAGAR RAILWAY STATION, LUCKNOW cuenr: LDA, FPC CONTRACTOR: - BL. KASHYAP & SONS LIMITED “Wiis DER has been ws abby Dea, La Roan flyatf Ch let ses pera bas —— ia et mi Sau 6 CONSTRUCTURE DESIGNS PVT. maeibinoor senun ou ergret bres ct Tesesiny Soh ee pan 00% nda 3 oy DESIGN BASIS REPORT OP oinsnm i) RLDA/LKO. Development/Redevelopment of Gomi Nagar RailwaG Station, Lucknow (Concourse) Date: 29.04.2003, GNRSDBRCRE Page 1 of27, Qn. % aa BLHASHYAP CONTENTS 1. The Projet Bet 2 Codesand Stands 3. Material of Consrion 1 Reinforced Cement Cancete RCC) 1 strut Set 4. Loading Dent Load imposed Londs = WallLonde Wind Loads 1 Scsmic Loads Temperature Method of Design Aralyss Methodolgy & Softwar sed Concrete Cover Equipment Fayade Cleaning Syste 5 ‘ 7. 8 9. GNESDBRCRE Page 2 0f 27 Constructure Sian Se Constructure — aL nAsHeA 1. Project Brief Bre Deseriton & Stent features ‘The eoncouse is 8m long a 28m wide having height of 9 rm rod 1 Noar and Sm fom 1 toroot- The wo blocks (no terminal and sot ein) are connected bya cance, ‘The Structural system wil be based on Modular Concept, Madar design represents the repetition af “Modulus which intrn, guarantees the sped of constuction. It cams tol or bringing together nd Seting oul individ elements Te following Moda lerens wil bused ahs poet, + Grdsystem ued + Modularity of solumnscams/Slabs Modularity of trough root + Modularity oftoundaon. Seae: ‘Our scope of work oti projets flows: 5) Toprepare Design Bass report 1) Tosugest best uted structural system $8) Topepare the 3D analysis ode |) Toperfor the stuctural design in accordance with he provision ofthe levees, ¥) To coordinate te structural design with he rhiectralerics requirement ¥)Toprepme saci dain othe espn performed, Applicable Structures fr his DBR STRUCTURE NAME STRUCTURE TYPE ‘Air Concourse Permanent Design Lite: ‘The design if of he strctre is assumed as 50 years for Ae concourse. This requtementi pial for concrete works a5 wells forthe composite designee constion ant not appliele 10 replaceable fishing materi, waterproofing membranes a them into (if ay), Hence tic mainenaneerefrishment is equ forall replceble mater for longer i Basie Dimensional Clearances: sie dimensional clearances as eguied by Raiaysto be fllowed spe Indian Raiays schedule of dimensions (RSOD)(Atache in Atnexue-A) Buln Lact: Site forte proposed projet of Developmen Redevelopment of Gomt Naga alvay ston is cated in Gori Nagar, Lacknow Page 30627 Bion Og Constructure bs 8. HASHYAP Src Sytem Concourse Stectconerte composite stems have Fecome gute popular la recent tes Beas Of tet advantages aguins conventional construction. Composite eonsrcion has the biggest advantage of Combined action otal and conrete instar design a well as consrtion, This sytem esas Inspedy constuction with a posiaity of working o pall rot ‘composite sel frame sructul stem has been proposed foal ors with enough sifhess by Providing sear wall to kep lateral displacements within limits. Steel-coneret compost ns Fane heen chosen o reduce the column sizes. Further, compasite ler ste hss been inraicod wing tapezsdal prof composite steel deck shetng fr economy and fst constuction exeston, The lateral resistance sytem shal he ductile shear wallBracs with SMRF, with R>S in fine with provisions ef Tale 9 o 18-1895:2016, Pa) ‘The Intra ons wil he resisted by shear wall, Braces and the columas (base on the stata trangemen), ths the conecing teams being moment connected with the clums The proposed ‘stan wl comply th he provisions oIS1893 say considering ae tansfer meson ‘suggested as well a ike tral veer spacemen provision ofthe lense Eneasedste columns (*” Seton laidoutin a etangulaSquae grid according tcc and sutra needs. The or system cos of primary an secondary telbeems suppor en over sek sab Clu to coun beans ate monet resting eam ad al secondary beams we momen released beams ndstal be modeled accortngy inthe ETABS, In RCC wall & compost corns ste members an be eeted up 4 lor lung the stel column lf and concrete enesing of the sol columns shal be done herefer, ‘Through Rook Encased columashave pope for Aireanenire roof Aluinin Stnng Sem sheet wih hers inslton (sper speiieations and solar panels fr Ai-concourse rot Bex Pstin shail be wed for root The Ineravessance stem tll be SMIRF, with R>S in ine wth provision of Table 9 of 15-18932016, Pare, CNRS DBRCRI Page 027 o, — pLaneueae Constructure asi Structural Framing L L HH fe ee ee Constructure BLURSHYAP Codes & Standards “Thwoaghouthis specifieatin, references have been mao appropriate nan tana & ATSC code (as and when requires) wit aproved lve of workmanship andr materiale comprehensive lst of relevant standards i compiled below La ‘183875 19872018 Code of Practice for design loads (other than earthquake) for Bullings and struct Al pats) ‘+ 18:1895-2016(R2021 Criteria fo earthquake ress desan of stuctne Foundatons:- + 15:1080-1985(2016) Code of Practice fer design an construction of shallow foundations ‘noise tan eating and shell) '15:19041986(202) Code of Practice fr design nd constuction of foundations in soils genera requrement ' 15:2950.1881(2013) Coe of Practice fer design and constuction ofa founltons + 15:2974-1998(2013/2015) Code of Pratice for design and constriction of machine Foundations (ll pas) + 15:3000-1976/198920132015) Code of Paste for salcalition of setement of Foundations (Al rs) * 18:45 -2000(2021) Code of Practice for pn andeiafrced ence 1 15:458 1988 Speifieatin for posit concep + 153370.2021(Paniv) Cade of Praie for eoneret srs forthe sorege of guide (Al a). ‘+ 15:526.2013 (R2018) Code of Practice for eahquake resistant design and constriction of aiding + 153525-1960(2013) Recunmendain for detailing ofreiforcedcoerte works. 18: 1786-2008 specication for high swength deformed stot bars and wires for concrete infer + 15:102622000 Recommended guidelines fr cnerete mix son. + 1S: 1895 (Part) 2016(R2021) Criteria for catquake restart design of structures (Genera ‘provision and bili). *18:13920-2016 (R202) duce design & dealing of RC sities subjected sei foros Structural Stel & Composite Comstrction:- +1 on 20072012 Cae orate gr constuction nse = 619640019) Cat Pei ofa he npr ling consracton 8-199 Dames obra sel am clu hal an angie ston Go 815-1988 Calo Prac rue ote el craton ni st So ey buuie Constructure + 18:4000-1908 High went bots ia stat sructures Code of Pate. + 15:7215-1995 Tolerances or fbiiton of ssl rts + AISC'360-10 Specifeation foe Suuctural Bulag (Only Chapter rele fr cmpaste Beam sd colnn dein + ECA Design ofeanpositestel and eonerestucturs Pat Misetaneons = '18:432(pan2)-1995 speciation fr mild ste and mem tensile steel bars and hard rawnstel wie for eanerete reinforcement ‘+ 18:6515(part 2001 Standards for at-termite wean + 15:1905-1998 Cod of Practice for sacl use of wrinforsed masonry + 18:3067-1995 Cade oFPactice for general design deans and preparatory Werks fo damp roofing and water proofing of bailing. 1 $P:-1998 Handbook for srt engineers (all pars) 1+ SP.1-2016 National Building Cade of nda 1 SP16-1999 Design Ads or enforced conte o 4561978. + $P:22-1982 Explanton handbook on code for eathguake engineering and IS:4326- 1 $P:24-1085 Explanatory handbook on Indian Standard code of Practie fr pln and reinforced concrete 1 SP4-1987 Handbook ofconerste enforcement nd detiing (SCIP) Soil and Foundation: 15: 8000:1976 Code of practice fr calculation of setement of foundation, + RDSO reper no, BSI15{Rev 2: Guidelines fr compasite construction including shee ‘Comectors, * DSO repr no. BS Rev 6: Guidelines fr use of high senath ton sip (SEG) bots ‘on bridges on Indian Rava *1S:269.2015 Specification for Ona, apd hardening alow best Prtnd cement 1 13:458 1008 Speifition for Porta las furnace slag come. 1 18:1480-1891 Speciation fr Porand pzzaana coment + 18:4031-1901 Method of psi test for Pond cement. 1 18:388 2016 Speciation fr couse and ine auaregates rm natal sourees for ener 1 15:516— 199 Mod of tes for srength of once. 1 18:1199-1899 Method of sampling an analy of conn * 18: 15662000 Speifiation for plan hard drawn ste! wie fie ar conrete enforcement 1 18:4990-1998 Speciation frp} voo fr eoeret shitering works IS: 265-1999 Specifeain or integral ment water prootiag compounds Page of 29 sain Constructure + AWS D11- American Welding Society (AWS): Stuctual Welding Ste), + ASME Seell-Par € Specfctons for welding Rds, lets nd Filler Metals Mary of above Hist standards may not he diet wsed in doled design, however, the comprehensive lists captured 50 that an appoval for thei we i obtained at DBR stage set. ‘Wherever appropriate Indian standard. does not exist for any item, appropriate Bish sanrdtAmerican standards wl be wed Code Merarehy:= Orde of preferences feos shal be as flows: Lis IRs Re AISCIRSEURO Othe tfeenes sed in section 2 2 5 GNRS-DBR-CRE Page 0127 Gen % Constructure aa! BLHASHYAP 3. Materials of construetion Reinforced Concrete ‘The cement used fr RCC week inthe sub seucue super srustr wl e OPC (Grade 43 and $3) vith FLYASH conforming to 1S: 8112-1989 and 12269-1987, The Fly ah % willbe meting the sign mix requienent andi ne wth tiple of 15486 181489 pct Fly ah is a binder material, Aspe seton 5,1 148, the amount of ash to beaded shall ot exceed 3% by mass of eomen Ply ash decreases the permeability of eoneete whieh in tas benef. The use of lash reduces allay of ee ines nd pemeabiy hsrests in erosion prevention I iroves the strength ‘overtime and ths, ofes pene sueng tthe bald. ‘AL RCC works wil be mechanically vibrated to produce dens, soul and durable concrete ws pet ‘specications. The wir quality wedi ll sages of constuction shal ticly conn to IS. 436 ‘The grade of conrt inthe losin at feam/sb-clumn junction shal be kept matching wit he ‘olun grade Below. However the extent of this coer eto the ib shale ied 6100 suirouding he cola eine The following grades of Reinoced concrete stl be ate: “Table 1 Grade of RCC deren Deseriion Gre Tope of Cement wed 1eMin grades perce Design Mis. Shasiaes 19456200) cL 1184620) — Combined Fong | M30 ‘Fc foundation ‘Shear Walls Cotumns | MS OF Sab ws oR ‘+ Allenfrcing ste! tobe usd i the strstr elemental be: High yield suena deformed TMT bars wih minimum yleld sess of SOO MP nim lngation o 16% wth provision of UTS/YS aio >1.10 ad ther specifestons eontorming 10 LLL able 3 of 1: 1786 shal be opted for om o 32mm di ars Structural Std Sirus sie enased column shall be bul yp ia high ese tal with a ye sess of E450 ‘Ma conning 8: 2062 Me ey BLHASHEAP Shea sts sal have yell stress of E450 MPa, Dia of 19222Sn hall be ws Based on the modular eqitements of eam Spars spacing foresee Bols of grade 8.825 per 1: 4000 0 Be used which ster argue applisation wl develop fiction ‘ip Anchor odsbas sal be £250 MPa conforming oS anda Constructure Welling elctrodes shall be E8018 conforming to AWS DI. Welding procedure, speciation sheet (WPSS) and Welding Procedure specifeton Record (WPSR) as per siplton a por AWS DL should te approved fm the competent autor ofthe sd bare at of te execution of | work ‘The Mooring and waterevaing hl bem per he spin GNRSDBRCRE Page 10 of 27 Glen ~ Constructure — B LURSHYAP 4 Londings Dea ta: Folin el biking mrs ve een cosine ith C21, ble stant ‘able? Un ugh ang materia Dect oT ani senate sy Pe i stg ae Tea] | RN Cana RN Fl it SERRA Br Ca er ag od |S acs —— |S | (Comet 2m bok pronto sie) | onan) Naso lng cps Sie Fomor iT Taner em Ta ‘SeperImpose Dead Lands Following SIDL weighs have ben considered in socordance with wit weighs gven in Cl. 2.1, able 1s: 875 (Pat) 1987 “Table 3 Superimposed Dead Lands TeV LOAD TYPE | SIDUAKwina) [Fino sme rh aa) Live Loads Live lois considered ia design ae in accordance with table ISHS (Pat IFI987 for ‘ype-Assembly Bulag (Live lads sed are hose mentioned in ods) “Table Live la TEVEES ‘LOAD TYPE” [ LUKamaa) Series Lads ‘Series lon of 5 KN? ake for Concours, Cottra aad: ‘Wherever apicbi, llowing Collateral lads ar then =) eo Conslructure —— BLHASHYAP Wind Lands ‘Wind loads have boon worked ut bred on basic wind peed of 30 mi tein of eatgony-4 structure sper <1 4.2.2 NBC 2016 vol, a, section as per IS 875 pur-3.21 uli sumed elows Basing data forthe wind Table 5 Wind parameters ase Wind esd Ve [Som pret) Terai egy 7 ik cof ae 1 eran eight & suse se ei | 105 Tepowry cer iH MAP OF INDIA Page 120627 S. Gian ° Constructure " BLHASHYAP Slam Lond As pr 11893-2016 (ReafTimed 2017) the roposd fling fall under Siam zone “Fig 5) Seomie sme as pr ISTO9S par: 2016 ‘Time pei caelation ‘The approximate fusmenta tanhationa ata! period Ta of osilaton of ure wil be Cateattes in aesondance wit clause 7.42 of 1818932016 “Table Time period Height | Time period] Time Siractare Type structure | catesaton | peta n). forma “ Air concourse pose " 075 Composite MRE a pa a Page 18 027 SZ He Lanse Constructure importance factor ealeaation The importance for fr concourse ner sondern inthis rept is drive based on abe (Clause 7.23) 1818032016, Table Importance fete Surecure | Importance factor “Lateral iad vesting stom, Ar eansoar| 13 Trporant sevice & communi buildings or stares Response relution factor akin Depending upon Ite oa sisting syste ofthe strut, response rection factors gven as per table blow i carpisce wih Table 23 S800-207 “able 8 Response reduction fator Structure | _Respome raucton ator “Later Toad resisting tem TA ensue 5 Spedal Moment Resisting Frame (SMR) coring to not I of Table of 11895-2016, RC an steel rete in Seismic Zanes I, IVa V Sal be designed be ductile and fence, OMRE (ordinary moment resisting ame) ae not allowed in thse seismic zones. Hence, cre mst be exercised in selecting the neal loo resisting em of the suc ‘Speci Moment Rising Frames (SMRF) 1 Special moment fames shal be made of 50 steel of $2062. compliance with sein 1211.2. ofS 400:2007 all bat-o-colurn cenntons sal be iid and designed withstand a momen fa east 1.2 ines the al plastic moment of te connected ‘+ Thecommeton sal wiistand shes resulting rom 1.2 DL 0.5 LL. pis the sea sing fern ‘thespian 2 Npin these direst at ach ei ofthe Bem The shea strength need nt cxceed a ole coresponding ola combination: 8) 12 DL+05 LL #255 EL ang )09 DL + 25 EL (Clause 121122 and 122.3 ofS 4002007), ‘As per elas 1213, eam aclu ston skal either plastic or compact.» The stone Seleted fo beams an cons shal satis the fellow relation: Ties ‘Where 2Mpe = sum ofthe moment capacity inthe con above and Below the sm centerline sa p= sam o te moment apo in tb Deans athe iatersetion ofthe bem an alu ‘entries "Fixed column ses and ter anchor bos seald be designed to withstand a moment of 1.2 mes ‘hel plastic moment capacity ofthe column seston "Bots ied an hinged clu bases sal e designed o withstand the higher of ll hea under ies the ghar apy the ola ection GNRS- DBC Page 14 of 27 S2 Fellow <“ Constructure oe BLHASHYAP so ype “Types of ols te lasifid as Type, Type and Type acconting to 1S1893:2016 (Clase 642.1), Type and I sol referorsk x hard sis, edi sf sol and sof sil rxpectvely. ris necessary to determine the typeof soil on whieh he sce wil be placed in onder to determine the caret ptr to be se fr estimating Sas Based onthe spo fanaton and soil he net Bearing pressure in soil can be intease as pee Table 1 and Table 2 of 818952016 ‘A Ground Type lis assumed for this project. Annex C ofS 189-Part 1: 2016 provides a indication ofthe rage of geologies of India. Allowing for supetil weathered roks and superical depeits sch as alluvium, which shown tobe extensive in northern Ini, Ground Type It hse heen ebm, ‘This apples to medien sti ground pris and alo assunes thatthe groud isnot scape 10 Tquefcion or yee soning under he design eartnguakes. ve — ee sort sou ig. 6 Dexignaceleration oxfcle Sa) a par IS3-purtt: 2016 GNRS-DBR-CRI Page 15 0f 27 o, KS > rae Constructure ‘Rig. 7 lithological groups as per ANNEN-C, 18 1893(part}) 2016 Sale Weight Clause 7.3 ofS 1893 species to consider fll dead ps percentage of impose lad for estimating esign seismic force. In compliance with clause 7.2, impose load on ot except esupment and permanently xed fale ned ot be conse ower fr air oncourse, where impored lon ir above kN, 0% fl impase la shal be onside in calevlton of istic weight (le-10, lause 7.3.1) Sismie Anas Methnds As per cause 7.7.1 of 11895-2016, except regular biliings lower than 15min Seismic Zone the linear dynamic analysis shall be performed to aban the design lata forse. Hence, the response speerum method of dynamic analyse shall be employed forall suc type of strates, In compliance with clase 773 of 18 1895:2016, the design base shear estimated wing dynamic sass de slot eles han eds esac sing fone ood 9 fe = BLHASHYRP Consractre Damping Ratio ‘According to clause 124 of 1S189%2016, iespetve ofthe water f consrstion, the value of| ‘damping shal be consioredas 5% feral damping for etimatng horizontal sisi xe A, ‘Vertical Earthquake Eset In compliance with lure 6.3.3.1 of 18952016, when te suc (Located in seismic 208 1V se V or (Gi) Having Vertical or pln ogni o (il) Restedonsoftsoilor i) A bridge oe (9) Having log spans or (i) Having age horizon overhangs of rut! members subsystems “The eects det vercaleachquae shaking sal be considered. Therefore, de tothe eng of pan ‘vera tet shal be consiered for bth he Zone Il nd Zane V css, “Te design seismic celeron spectal value Av shall be cleat as (4.646, 1819932016) With reference to Table Sv), bling undergo complex earthquake behaviours and hence dag, ‘when they do ot have lateral force ressing systems oremed along two pln dco that are ‘ehogoal to each ter. Hen, in complisnce with lake 6.32.2 and 63.41 of IS1893:2016, sch ‘nling systems shal be designed for earthquake lsd combinations listed below. ‘Seis vibration inthe lengudina tnsvese and vrialdietions hal be combined flowing he oe 1120324038 (518952016 63.4. IRC: SP: 114-2018, e422) ‘wheres the leadig semi direction and 2 are the emnng sisi ection “Temperature & Shrinkage Lond ‘The temperature loa has been applied incase length of site more than Am for seasonal ahd lial variation ad foe shrinkage ffs ts converted into equivalent temperature for applying in ETABS mode. nview of maximum and minimum peak temperature data availble, temperate load of 20° Cwil be considered in design of open rac na shrinkage fad of-5°C shall be pid on every ‘oor. Temperate lea isnot required for intermediate Noor deo onal tempera ld ENRS DBC Page 17 0627 * eo a ina Constructure 5. Method of Design ‘The design of Composite Corns & om is eng dane sing AISC: 360-2010 and RCC element ae per 184862000 and SP-16. Limit sare method sein followed a per S 800-207 for desi of ss ‘rucres and conection devin. The considerations forthe design of rete shoul be ols: (a) Struct sfey and sabi, (b) Tommoc the demands of sxthtcs conceived ty the Arte. (6) Avalabliy of materi equipment and exper, (6) Consroailiy ad ease f maintenance (©) Darby Allstar members shoud conform o provisions nin IS 13920, ‘+ Thedesign of RCC columns, beam & sls wil be done using 1656-200, 15 1895-2016 & SP i + Thedesign of Composite Columns & beam seng done using AISC360-2010 + Limit state method is bing flowed as per 1S 800-2007 for design of sel sutees, LOAD COMBINATIONS: ‘Service ond combinations a inate load combination ad for aa a design per Table of 46:20, 63.44 ofS 188partyaOI6 and tale oS 207. {Lod combinations Used for Strength, Serviceability ar tabulated below For the purpose of computing steses an defamation, the following minimum load types and ‘consequent effets sl be considered as aplicable Table 9 Lond Types and notation Dead Load DLASIDE, Live loads LL ‘Non Recible Live load NRLE Seismic Load in X-Dir EQX, ‘Seismie Loads in Y-Dir EQY, Wind Load in X-Dir Wix | Wind toad in V-Dir WLY TEMP Rise TR "TEMP Fal TF ‘Scaled Seismis Loads in X-Die RX. ‘Scale Seis Loads in Y-Dir Page 18 0f27 Constructure BLHASHYAP Servceaity load combinations and Ukimate led combi per 18486 and IS 1893 isa follows ions wed or ysis and design as Servccbiity Link Lead Combi “TobleServesbty Link Stat Lod Combinations Tive T Load Dead Load! | Load | Seismic | Wind Load | Temp Combinaion [OL | LL) __| Load £0) _|owL) | lol TRIT) bisttenp | 10 | 10 zi eae msos DUFEQ 10 E 10 E aS LAWL 10 5 F 1 os paiszge| 10 | 08 7 os | os pte Limi State Load Combinations “Tbte9 ita Lint Sate Lead Combinations Tive Load Dead Load! | Load | seismic | Wind Load | Temp Combination _[(0L) | Lt) _| Load (2Q)_[cwL) | foadcravF) DLEALUTemp | 15 15 5 a 09, DLFEQ TE or09 | — 15 5 05 DLAWL 1S0r09 | 5 1 05 DLXLLEQWE| 12 zy 12 12 05 Notes ‘Earthquake and wind loads ae reversible ‘Wind load and carta loud ar eorsidered for bh xy ditions, Whenever imposed load js combined with eahqunke load, the appropriate pt of inposed oad a pei in IS: 1893- 2016 Clause 733 of seismic cade wil be used both for evaluating sata effet and for ‘omlined oad fess usd in ch combination ‘+ Serviesiity loads combinations wih sub ve lad eduction fara pr IS: 8 (Pan-2) ll be wd for oundton design, ‘For consrston tge lating, | DL + LL of 100g)? to be considered, Foundation stall be designed accordance to IS 456: 20002016). Ansiysis and design of rafeombinesslated fxndition shal be dane by safe and design of lated fotng,rsinin Wall bse tobe prepared in excl shat and provided in format. The foundation has heen designed by csideving max allowable net earn presse (Qh net of 20.0 Tia. a2 dept as per les si ‘investigation repon maximum allowed setlement 75m fr raft and 50 mm fo ote ftng and Page 19 of 27 9 Ben bod Consipuchare oz BLHASHYAP Design of eompaste ment ‘Composite Colum ‘Thestel oksmns comprising ofthe two strstr fos ae strstr steel & strut coer) Shall stat fom prox. 2Sm below the Noa evel his ensing tht the compoite bea fing for pli level is facilites. The AISC: 360-2010 Speciation provides simple and practical ‘methodology fr compte colunn by pemitin dsin of composite calms ty LRFD (Last and Resstanee Fair Design. The design methodology is wll layed in ETAB software modelling and ‘he suing seen se sae nd pret. Composite column design willbe done as per AISC: 340+ 2010 and caleslaton hal be submited np frat of excel hee ‘The consrwtien methodology isexecutn endl 35 wel as time saving ince structural steel oma upto lors canbe erected & ted with oor ructrl beams. Decking ark ean be taken yp on these loos. The suiiieney of structural comm alone is checked for the long ofthese four levee subsequently, floor wise, the ceinfrcement is putin positon & columas RCC exeuted to get campsite aco’ Ofcourse, te composite coin design atest the il loading which tal be nce ont eral floors contaston. Secondary beat Dively dsined sing ETADS. Pre-camber ay be wed where necssry, 0th the deft is suitably adresse. The web openings willbe seteialy provided fer provision else to pint of Inet, where moments wl be minimal shear wil ono ewe pak Primary beam (Moment Reiribtion in bsams design) “The reistribution upto 10% is accepted by way af lst design’. Accortngly the primary aalsis fbeans is doe coavertinsly& ten moments reds sing plastic design only up to 50% so thatthe hoggin (suppor moments) ae costrelled win the designe mits & he sagging moments ane lacreased for which the section provision efi made, Aseprate tad! wl be pared in TABS (only forthe primary bus) whee the reisrbted moments of design only hs ensuring ‘thatthe asumpion frigid joints is maintained. An inovatve deck placement with an eye towards test beam depts wll be adoped whore the beams wll not necessiy spn nthe dretion opposite 1o the corupatins of the sect. The exet of omens obtained (afer redistribution wing pls theory) wl ececked fr "no-oversussag” enditon, Connections design ‘The comnectns shoul have the requ capacity considered after redstibution of moments. Thee isn possiblity obi failure since the ductile conection wl pemit ton atthe jot suing no poi of aden fre Serie Rewiramert “This given wt lloing lmao: For Venta deletions (Total oad detections) Span50 for Servicii, + Spa/360 for materi suscep o raking. Lateral displacement of Sucre Heigh 00, + Drift shal e 04% of ty sight. flonan iting rk with 0.2mm, Page 20 0f 27 Constructure BLHASHYAP Ditt-The maximo horizontal relate diplacement de to earthquake feces betwecn twa sscesive Moors sal ot exceed 0.004 ime the ference lvl Between hese os, lor vibrations Waking veo Foran beste tpl ang du taro asin bling ein i itions being by tiling capa Type nbs, bes sient ns of Noe vias is waking excaion a levels tbe ep win ova Hs fo ens it aves omer om big ezapans ep amiinan, waking accent bees tan? = 0.005 and Calulaton sal be adopted diet rom ia 1 Viratione due to ain movement: ‘Vivaions due to movement of wai oe checked and ep in acondance with he weve sestons of design ntonaictertonl codes and relvar erature wil be refed fr agate viaon- ono Noor desan Forth sme, EPC contractor will appoint constant whichpeciaizes in Viton Coto ystems ‘Te vibeain contol documentation canbe provided ata ater stage 6. Analysis methodology and software used ‘The bln halle alyzed as compoststelsructre sing Ea software for Tower consiering the relevant Indian Standard Cae. Applicable Dead, Live, Wind and Sse Lond along with snpeoprit lad combinations have ben considered, Sova like ETABS, STAAD, and SAFE shall te used for nays and design. Al secondary compost steel beam eonnctons oman beams ae ‘Simple connection and rimary bam and cantilever to columns te conseed ss moment conection, ‘The floors comprise of RCC slabs over deck sheet, which suppaed over strstr! beams (pte sider) in compose manner. This mechanism wil ens that the in-plane stesso ae tht no two nodes an move relatively to each oe. That, hey all alt or defor together a el as there sno elongutionSuain developed. Therefore, a Rigid Diaphragm acon shall be assed i the TABS analysis so that the water of ead to ames. All odes within the diaphrgm extents sal be ‘ied together inthe mode to the cee of rid ofthe sytem with aie rns. This fui i avaiable in ETABS maellng. Foc design finial lens sible exes spressheets aro he wad f ‘Additional Considerations to design method pansion Join "Expansion joint ae recommended when tute exeeds 4 length, The wih of the jin being calelte sper 1S-1893-2016, case. 113, Nowever even fe Inthe balding this projects more than 4m, the expansion jis in CNRS DBR-CRI Page 21 027 2 Eilon. “ Constructare a? SB LAASHYAP Wald techneogy & allowable tresses Welding technology & allowable steses to bes per AWS DIL1 Aeron Weling Scien (AWS) 7. Concrete Cover Nominal encrte Clear Covert All Reinforcement nluding Links (As per Clawse264 of 1S: 456- 200) considering Enisonnent conden is Moderate & fre resistance of 2s Structural Flement Tice Nominal Cover Sex Wa nse Sr For Simpy Support 401mm Se Comino ee ra Simpy suppor oor 35mm 8. Equipment (DG Set & Others) DG setts is ker elea ram the main framing by way of suitable separon gp so tit he sbi of vibration trmission doe nt ie. + Other equipment whichis thr satiorthose wih niga vibrations sah scooting towers illb ep ety on the Mors by way’ wibration ion pa 9, Structural Maintenance Periodical inpeton ofthe terre shuld be done oii repair work and ake nessa ction according. Mainnance shouldbe Joe inaecodance with IRS Bdge manual. Some af the commen ‘mainenance works have bec listed blow For Structural Stel 1 alae works ‘+ Periodical Thorough Paint Teenie steel werk shoud be pnd argu neve which vary hom xyes in ard zones to one yearin hgh cose areas. The chit enginer shall escrito she periodic of paling. ‘+ Patch Pa: When small are of paint show pronounced deterioration, which requires immediate rem, its pot desirable o wait forthe girder or te members whole beeing ie or pric aiming. The fete ares muse pth pie, Page 22.027 Se ae lien. puaseanee Constructure 2 Bot 1+ Looe ots suld be identi un td ‘+ Ifa tit is found be ecko, cause of eck should he Hen and bot shuld be replica immedi + For HSFG bots, psiming shades and methalogles bbe followed a pei in IRS bridge nal forthe ge a whole Force: ‘Theres around bearings shal be ep feof ells, devs dst l/s Drainage stem stl ehoouphly cleaned and repied a ees fore the onset of monso, Protective surfic oat, where povided, shal be mained Superstucture and eorings shall be maintained a5 per the design eequiemens and any beicienievdfects ated during inspection hl be tend 0 GN DBRCRI Page 28 of 27 7 C2 Geiian. A 2d Canstructure ALHASHYAP ANNEXURE-A (SOD) eo BLHRSHYAP Consractre MAXIMUM MOVING DIMENSIONS (SOD) DIAGRAM NO:- 1D (EDOVT:2202)1676MM GAUGE OF SOD, REVISED , 2004 MAXIMUM MOVING DIMENSIONS, DiNENSIONS OF R/ 86 STOCK GNRSDMRCRI Page 25 of 27 il BLHASHYAP STANDARD DIMENSIONS IN STATIONS TO SUIT 25 KV.AC. TRACTION SCHEDULE LCHAPTER I / > ee [ | GNESDBRCRE Page 26 of 27 Contbructure RLNeHEEE 0 aan DREITETS a i ONS DBR-CRE oe (“ANOOP KRISHNAN, to Deosrinentat Cut eoancetnn Indian Insitute of echrooey fe Haurkes New Ooh 10096 pon Page 27 27 No. RLDA/2023/Gomtinagarstation/EPCContractor-BLK/(2847)-Part(1) (Computer No, 2427 poh aon EN eaen No. RLOA2023/DesionUivDBR Comespondence/263 ate 17.042023 Chief Project Mana theknow * Rail Land Development Authority ‘Sub. Approval of Suctural DBR related to Construction of elevated Concourse for the ‘Work “Redevelopment of Gomti Nagar Railay Staton Lucknow on Modular concept on Engineering Procurement & Construction (EPC) Mode.” Ref: Stuctural DBR received on e-ffce vie fle no RLDA2023;Gomt Nagar Station EPC Contractor BLKI(2B47}-Part (1), +. Structural Design Basis Report related to project mentioned in subject was received vide notet!t and 2 of fle ne RLDA/2023/Gomti Nagar Staton/EPC Contractor BLK/(2847)-Par (1) on fe-ofice on 14.04.2023. DER No. Né related to Structural DBR of Ar Concourse was submitted for approval 2. Above mentioned DBR is being approved subject to incorporation of points given in the Annexure A of tis letter 3. Above mentioned DBR has been examined by Design Unit from coda! point of view. Corectness of site-spectic detais Included in DBR and compliance of DBR with Contractual/RLDA requirements have not been examined. 4. This is for your information and futher necessary action please. a 1 lo. RLDA/2023/Gomtinagarstation/EPCContractor- F to, RLDA/2023/Gomtinag 1/EPCContractor-BLK/(2847)-Part(!) (Computer No. 342 Observations! Comments over Design B: ‘Annexure A. Report of Air Concourse related to Redevelopment of Gomt Nagar Railway Station, Lucknow (Air Concourse) S| Clause nos Jomments given N| “Pagene. Comments 1] Heading 1, | As per Tabie 1 of 5 675 (Par) A Conccurse and Through root © be considered Design Lie | as imporan bukings and structures 100 year Design Me, This may be seen. 2 [Basic Stuctral|- Basie Structural framing should be done consiering the overall Archictural Framing and] itent of the structure Itt to make sure the sructural framing gel up wih General ‘rchitectura inten and enhance the views. ‘Arrangement Drawing = General Arrangement Drawings of Concourse - The bracings given inthe ‘Gouunn may crete hindrance weh te functionality ofthe platiorm. May check wn the Architectural intent these braces are given 3 | Heading 2, [+ In hierarchy the Indian away standard (IRS) codes to be prefered frst, IRS Gaiae, an] coco art ppc elvan 1 Code ay be fore «+ tnctan Raiway Standards to be refered for design of structures which are Crossng ever vacks orn ven of racks such as Concoure, Trough Roof Sle so, Relevant Indian Reiway Stondaré (RS) Codes and iR Policy to be Used forthe sttura sign ofa oncourse «Accordingly various factors o be taken in Seismic design shou be taken as per the IRS Seismic Code “| Matenaisof| © The latest versions of IS Codes tobe refered Constructor, Cl 3 ‘+ Qualty Assurance Pian (QAP) covering the various stages of Fabrication, Matera. & relaiod aapects shoud be get approved from Competent ‘ithrty before star of Fabrication work Get 216 2 fo. RLDA/2023/Gomtinagarstation/EPCContractor-BLK/(2847)-Part(1) (Computer No. 342 soo. " 5. | Heading-4 Leaaings =p Dead Load and Superimposed load. ‘The codal reference for most of the items found in table 2, however for some items such as Facade load, ete. i not found Ih Table 1 of 1S 875 Part 1. The basis of these weights tobe included 9 Table 2. Live Load and Wind Load: ‘In case of Concourse, FOB and Through roof, the lve load should be as Per IRS Bridge rule * As per IS, basic wind speed should be 47s for Lucknow Gomt| Nagar. May please chock ‘= Risk Cootficient factor K1- tie tobe considered as per important building ‘+ Terrain Category, K2 and KS shouldbe checked and verted from the fleld unit ‘Superimposed Doad Load and Service Load, all seem tobe taken atthe lower lend for Concourse. Service Load should be taken as minmum 1 KNim2 and ‘minimum fishes for 3 KNim2, as Air Concourse ts 2 type of anticipated ‘occupancy for business related works. ‘= Air Concourse is likely to be @ business activity hub. For both Service Load and Live load aspects of future expansion may be considered. Possibility of taking 10 KNim2 of Live load may be explored, If found feasible from Contractual point of view. ‘Selemie Load: IRS seiamic code to be used for various seismic parameters for structures which are crossing over tracks or in vicinty of tracks such as Concourse, Through root, ete Soil Type: + Performance of soi including te iquetaction potential during seismic activity ‘and i effects to be considered dunng seismic design of structure. + Moreover, the resutassumptions taken from the soll investigation repor io be confirmed by the flé units ‘Seismic analysis: + Eifel of setament load while designing stucture may be included in DBR, + Effect of vibrations and noise due to trains on varous structures considered to be included in design of various structures. Maintenance Methodology + "Some af the mainienance methodology has been discussed in the DBR. The ddelaled Structural maintenance methodology should be. approved by Competent Author fr folowing given the Service Ife of structures, Dent a4 0. RLDA/2023/Gomtinagarstation/EPCContractor-BLK/(2847)-Part(1) (Computer No. 34% 440608; a 0. Heading 5, Load combination Method’ of * Lond combination should be ae por relevant clause of IRS Codes, if Desgn applicable. Actual load during construction, erection and launching (as per approved ‘construction methodology) to be considered Composite column ' Launching and erecton loads of various stuctues such 36, Air concourse (rough root, lc. ie not discussed in etuctural OBR which depends on launching methodology. These aspects shouldbe incuded in OBR. Primary Beam (Moment redistribution in beam design) ‘+ Relevant Code and clause fortis descripion shoud be incorporated. f rot ‘supported by any codal provision then the same can be omitted fom DBR. Servicoabilty Requirement ‘© May kindly mention the relevant coda clauses. Foundation Design: 1 Feld nit should crf the values of soll parameters mentioned in OBR for {foundation design a8 per Soil investigation report. easing __§, | Concrete cover Concrete Cover |» Durablycttera in intemal members should be based on the environment ‘exposure conditions However assumed exposure conditions in the foundation should be based on the local sol conditions and should be decided accordingly. Field unto conten the same at their end 1+ IN DBR, Moderate envionmental contion and 2 hour Fre rating is ‘considered, Field unit to vent the same with Architectural OBR Gem 48 4 Design Basis Report (Concourse) Projet DeedopmenRedvlpment Gant Nagar Lacon Ray Sa Compliance Report Rel, Dogo. GARS-DBR-C-RE Page 103 Design Basis Report (Concourse) Proj Deeopmea Reem of Gr Nagar Lackaow Ray Sian By at Ret, Dee. No. GNRS-DBR-C-RE Page 203 Design Rasis Report (Concourse) Rel Dae. No.- GNRS-DBR-C-RI Page 303

You might also like