Anode Selection

ITEM Internal External

Anode Type ATR-208-DC-1 A-180

Anode Type ATR-208-DC-2

Anode Type ATR-208-DC-3

Anode Type ATR-208-DC-4

Anode Size 1160(L)x10


1500(L)x60(W)x70(H)
7(W)x47(H)

Per anode Weight (kg) 18.40 15.50

Anode Quantity (nos) 249 102

Anode Current Output (A/anode) (Initial) 1.97 1.06

Anode Current Output (A/anode) (Final) 1.44 0.93

Anode Quantity by Current (nos) (Initial) 242.89 101.14

Anode Quantity by Current (nos) (Mean) 228.92 60.65

Anode Quantity by Current (nos) (Final) 199.38 68.90

Required Quantity ATR-208-DC-1 (105)

Required Quantity ATR-208-DC-2 (108)

Required Quantity ATR-208-DC-3 (24)

Required Quantity ATR-208-DC-4 (6) 102

Total Supply for Internal / External 243 x 3 =729 102x 3 =308

Additional Anode for Tank. 19&20 (P&S) 18

Total Quantity for 3 Spudcans 747 306

Supplied Quantity for 3 Spudcans 747 306


1. 1. 2 Painting

Method of
Dry
App
Film
B : Brush Est. Area
Location / Area Product Name thk /
coat R : Roller M3
S : Spray
μm
AS : Airless
Surface Preparation

Blast clean to Sa 2 ½ ( ISO 8501-1 )

New Plates Muki Z no.2001 FW Grey 15 AS 231800

Surface Preparation

Solvent clean, degrease to remove all rust, dirt and other contaminants

Galvanized handrails ( incl Penguard Primer Red 50 AS 500

kick plate ) Futura AS ( Yellow 258 ) 50 AS 500

Surface Preparation

Spot blast clean all damaged, corroded area to Sa2 ½ ( ISO 8501-2 )

Light sweep all good and intact areas.

Power too all difficult and inaccessible areas to min ST 3 ( ISO 8501-1 )

Structural internal ducting Primastic U alum 100 AS 1467

Primastic U alum 125 AS 8000

Exposed steel pipes Primastic U alum (RT) 125 AS 8000

Futura AS – White Ral 9001 50 AS 8000

Steel pipes ( behind Prismatic U alum 125 AS 1000

insulation ) Primastic U alum (RT) 125 AS 1000

Steel pipes in high Resist 78 Grey 75 AS 3000


temperature environment (
Solvalitt Alum 25 AS 3000
service temperature 150-
400 oC ) Solvalitt Alum 25 AS 3000

Submersible components
Jotamastic 87 Alum 250 AS 22475
below waterline : legs, raw
water tower, pipes etc.
Jotamastic 87 Black Ral
All legs : from baseline to 250 AS 22475
9005
54.078m

Submersible components Jotamastic 87 Alum 250 AS 8525


above waterline : legs, raw
Jotamastic 87 Alum (RT) 250 AS 8525
water tower, pipes etc.
Penguard Topcoat 50 AS 8525
All legs : from 54.078m to
154.349m Signal red Ral 3001 / Signal White Ral 9016 alternated

Prismastic U Alum 150 AS 61075

Prismatic U Alum RT 150 AS 61075

Main exterior exposed area Futura AS 50 AS 61075


: hull side, crane, cantilever,
- White Ral 9001 cream ( helideck underside )
building & exterior of living
- May Green Ral 6017 ( helideck topdeck )
quarters, helicopter deck
underside - White Ral 9001 cream ( crane pedestal )

- Yellow Ral 1003 signal yellow ( crane )

- Red Ral 3000 ( flame red ) ( crane boom )

Prismastic U Alum 150 AS


Hull side draft to main deck
Prismatic U Alum RT 150 AS
level ( above waterline )
Futura AS Green Ral 6017 50 AS

Prismastic U Alum 150 AS 6930


Main exterior exposed area
Prismatic U Alum RT 150 AS 6930
hull side draft to keel and
Penguard Topcoat 50 AS 6930
bottom
- Red Orrange Ral 2001

Prismastic U Alum 225 AS 6151

Prismatic U Alum RT ( jotun


225 AS 6151
Anti-Skid to be added )
Main deck and top of
helideck Penguard Topcoat 50 AS 6151

- Grey Ral 7038 ( deck )

- May Green Ral 6017 ( helideck )

Main interior exposed areas Prismastic U Alum 125 AS 18574


Bulkheads, decks, Prismatic U Alum RT 125 AS 18574
deckheads, machinery,
Futura AS 25 AS 18574
machinery spaces, mud
- Grey Ral 7038 ( all deck )
pump room, P-tank room
- White Ral 9001 cream ( bulkhead etc )

Area behind insulation &


panelling, flat surface, Prismastic U Alum 100 AS 22220
stiffeners, etc.

Surface Preparation

Solvent clean, degrease to remove all dirt, rust and other contaminations

Roughen surface to create profiles

Penguard primer red


Galvanised ventilation
Exposed areas as per 50 AS 1467
ducting (ext)
surrounding area

Surface Preparation

Spot blast clean all damaged, corroded area to Sa2 ½ ( ISO 8501-2 )

Light sweep all good and intact areas.

Power too all difficult and inaccessible areas to min ST 3 ( ISO 8501-1 )

Balloxy HB Light ( lt green ) 200 AS 2000


Brine tank including piping
Balloxy HB light ( lt beige ) 200 AS 2000

Preload, drill water, clean


drain holding, void spaces,
Balloxy HB Light ( lt green ) 150 AS 35500
double bottom tanks, misc.
loose tanks, including
piping, fix water , buffer
tanks, expansion tank, fire
Balloxy HB light ( lt beige ) 150 AS 35500
maiss pressurised, surge
tank

Surface Preparation

Blast clean to Sa 2 ½ ( ISO 8501-1 )

Portable water tanks Penguard Primer Red 50 AS 4950

including piping Penguard HB Lt grey 125 AS 4950


Penguard HB White 125 AS 4950

Mud Pits ( active, reserve &


processing tanks, base oil Tankguard Storage Red 100 AS 12000
tank, dirty oil tank,
contaminated drain tank,
skimmer tank, trip tank, mud
return troughs, bilge Tankguard Storage Lt Red 100 AS 12000
holding, liquid additive
tanks, diesel tanks, diesel
oil settling/day tank, lube oil Tankguard Spec Topcoat
tanks, oil lure tanks, fuel oil 100 AS 12000
Grey
day/ settling tanks