TH Ac10 Instruction Manual
Topics covered
TH Ac10 Instruction Manual
Topics covered
1. When the temperature is too high, HI will be displayed in the temperature erea to express the room
@everweJJ®
temperature over the display range. When the temperature is too low, LO will be displayed in the
temperature erea to express the room temperature blow the display range. TH-AC10
2. Two AA batteries can be used for one year. When the battery voltage symbol flashes, it means the Programmable Thermostat
batteries need to be changed. Please change the batteries sooner.
3. Within the 20 minutes after remove the batteries, time and week will keep running. Please change
the batteries in this period.
Table of Contents Page 2.2 Feature
4. There is preservative on the LCD when out of the factory, users can remove it or not.
• Programmable thermostat
5. If you need to remove the preservative, just pull it from the corner and no need to open the thermostat.
Preface 1 • 5+2 Programmable
6. Don't force to install. When it is hard to connect the pin, move the display panel slightly. After the pin Production Function Overview 1 • Easy to program
aimed at the port, press the thermostat hard. Diagram and Description 2~3 • Easy to install
7. It is precision electronic products. Don't knock or fall it. Wall locations 4
• 6.8 square inch display
8. Don't let the water, mud into the thermostat. Subbase Installation 5
• Battery power or 24V Hardwire
WIRING 6
Wiring Diagrams 7 • Operate on 1 stage Heat and 1 stage cool
Operation 8~10 • Heat Pump without Aux or Emergency Heat
11.SPECIFICATIONS Mount Thermostat & Battery Installation 11 • Separate heating and cooling swing(cycle
Caution 12 rate) adjustments
Specifications 12 • 5 minutes compressor delay protection
Specifications
(selectable on or off)
the display range of temperature ............. .44°F to 90°F ( 7°C to 32°C) • Gas, Electric or Oil
1.Preface
the control range of temperature ............. .44 °F to 90°F ( 7°C to 32°C) • Optional temperature display of Fahrenheit or
Load rating ................................................ 1 amp per terminal, 1.5 amp maximum all terminals combined Dear client, Celsius scale.
Display accuracy ......................................± 0.5°C Thanks for choosing TH-AC10 thermostat • Low Battery Indicator
Power source ............................................ 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire) series. It's our best wish to bring you convenience • Display temperature calibration
Battery power from 2 AA Alkaline batteries for your daily life. Before using, please read the
Operating ambient.. ................................. .41°F to +95°F(5°C to +35°C) User's Manual carefully. It will help you to use it
Operating humidity.................................... 90% non-condensing maximum correctly.
Dimensions of thermostat. ........................ 118mm * 88mm * 30mm
2.1 Application
Description
1 stage Heat and 1 stage Cool Yes
A A trained, experienced
technician must install this
product.
■ ■ fW
3.Diagram and Description
11 12 13 1415
! ! !
Hold/Set key: Press the HOLD only once,the LCD display "hold",and the
thermostat keeps the current mode and setting temperature.in the cool/heat
,,,, r,... 6 mode, press it to keep the setting temperature, and the setting temperature
will not change in the setting process. In the cool/heat mode, press and hold
COOL - the key for 3 seconds to enter the setting interface. When power off, hold the
o. .
HEAT
OFF
key for 5 seconds to enter the parameter changing interface.
CoolHeat Setting ..... ............. 3
10············................ ..... ................................ . . . 1Cl Cl ~E1
I LJ LJ.ot cbol On ! *:.~•,. \
Sy~te?l
o. . 7 Clock/Week: Display the current system time and week.
,
FAN
.: ~~, .:
G!ill: Hea1._0n! ............. 4 Hold symbol: when the symbol displayed, the setting temperature will be
I r, r,OF.-,
.....
0 LJ.o°C
On Auto
~ ..........
o. .
RUN
...u
2 . . . . . . . . . . . . . . .....
■ ;t;JE:I T~~te I Cl •Cl Cl Am ~~~f$
PRGM Setting
o. .
HOLD
SET
..... ............. 6
10
11
Setting temperature: display the setting temperature in the cool/heat mode.
Battery symbol: it means low power when the symbol displayed, so
please change the battery in time.
f LJ •LJ LJ Pm mmlml
1 ............... . . . v
WakeLeaveReturnSleep
Day
Mon Tue Wid Thu Fri Sat Sun
............................. .. . . . . . . . . . . . . . . . . 16
. ... Cool symbol: The cooling relay start to work when the symbol displayed.
12 The symbol flashing means the cooling relay is in the set-up delay process.
...,
<tJJeverwe/f -
v 13
Heat symbol: The heating relay start to work when the symbol displayed.
The symbol flashing means the cool relay is in the set-up delay process .
14 System cool: The symbol displayed means it is in the cooling mode.
8 7 17 15 System heat: The symbol displayed means it is in the heating mode.
16 Fan: display the current mode of the fan.
17 Program setting: it shows the system is in the setting process
Description
Item Description
Down key: in the cooling/heating mode, it is for lowering the setting
1 temperature. When setting the program and changing the system parameter,
it is for adjusting the parameter.
Mode key: First press for cool mode, and second is for heat mode. Press
3 again will turn off the thermostat.
4 Fan mode: in the cooling/heating mode, switch the fan between on and auto.
Run key: Press only once.the thermostat operates according to the time
5 programming.After setting the program and changing the system parameter,
press the run key to save and exit the setting interface.
4.Wall locations 5. Subbase Installation
NO YES
NO
Installation Tip
Pick an installation location that is easy for the user to access. The temperature of the location
should be representative of the building.
6. Wiring 7. Wiring Diagrams
A Power supply
A Factory-installed jumper. Remove only when installing on 2-transformer systems
COMPRESSOR
RA
L2
L1(HOT)
RA
Typical 1 H/1 C heat pump system A Typical heat-only system
Terminal Designation C
C
L2
L1(HOT)
C Common wire from secondary side RH Transformer power for heating
of cooling system transformer RA
O Heat pump changeover valve RC Transformer power for cooling
energizes in cooling G Fan relay HEAT RELAY
B Heat pump changeover valve energizes
in heating Y Compressor relay
COOL CHANGE
OVER VALVE
W Heat relay HEAT CHANGE
OVER VALVE
A 1.Please
DD set on the heat pump system first
2.Please set the valve as heating/cooling system.
Wiring Tips: Typical heat-only system with fan Typical cool-only system
C
C
C
Wire specifications HEAT RELAY
FAN RELAY
Use shielded or nor-shielded 18 - 22 gauge thermostat wire.
FAN RELAY
a.Operation
(5) Hold key: When power on, press the "Hold" key to keep the setting temperature. It won't 8.3 System parameter setting
run the program and display "Hold". For example: now the setting temperature is 60°F ,after
When power off, hold " SET " key for 5 seconds to enter the parameter changing interface.
pressing the "HOLD" the system will lock the setting temperature to be 60°F.
Room temperature area displays each symbol of the parameter, and system clock area displays
each parameter of the parameter values. Repeat to press " SET " key to cycling display the each
parameter. Press "0," or" Q" to adjust each parameter. After finished changing, press " RUN "key
8.2 Programming setting to exit the setting interface and save the set parameter.(if there's no any operation within 30 seconds
when setting, the system will exit the setting interface and abandon the changed parameter.)
When power on(in cool/heat mode),hold "SET" for 3 seconds to enter the programming
mode: Display(Factory Press6or Default
Step Press Buttons Description
Defaults) Qto select parameters
(1) First is to set the system clock. When the clock area is flashing, press" 0," or" Q" to 01 SETS seconds cc FA or SL FA Select fast cooling or slow cooling
change the clock. And if you hold "0," or "Q" , the adjustment will be faster. 02 SET HC FA or SL FA Select fast heating or slow heating
03 SET FC Fore C Select °F or °C Readout
(2) Press" SET" again to set the week. When the week flashing, press" 0," or" Q" to change
Compressor Lockout delay time
the week. 04 SET CP 0 or 5 0
0 = none ; 5 = Minutes
(3) Press" SET" again to set the Wake time from Monday to Friday. When the clock area is 05 SET CA -5°to +5° 0 room temperature error correction
flashing, press" 0," or" Q" to adjust the time. conventional heat pump selection
06 SET HP 1 or 0 0 0:conventionalmode
1: heat pump mode
(4) Press" SET" again to set the Wake temperature from Monday to Friday. When the clock area is
Select cool/heat change over valve
flashing, press" 0," or" Q "to adjust the temperature. 07 SET Ob 0 orb 0 "b" = heat change over valve
"O" =cool change over valve
(5) Repeat pressing the" SET", then you can set the time and temperature of Leave, Return, Sleep, Intelligent Recovery Option
08 SET IC 1 or 0 0
from Monday to Friday and Saturday, Sunday by turn. "1" = Active "0" =Deactivated
09 SET 6E E or 6 E "E"=Electric "6"=Gas
(6) After finished the setting, press the" RUN "to cancel the setting interface and save the parameter. RETURNS TO
(if there's no any operation within 30 seconds when setting, the system will exit the setting interface 10 RUN NORMAL
and abandon the changed parameter.) OPERATION
9. Mount Thermostat & Battery Installation